ASSIST. 01 102 : A
CONVERSATION
Systems – that connect
Computerised Nurse Call Systemsclino opt and clino phon
25
Clino systems
clino opt®
Nurse Call System with Visual-Audible signalling
clino call®Paging System
clino soft®
Software Solutions for the nursing staff
clino tax®
Accounting System for TV and telephone
clino serv®
Maintenance and Service Package
clino phon®
Nurse Call System with Two-Way Speech facility
DIN EN ISO 9001Zertifikat: 09 100 4086
The sites mentioned below, which are our business premises,have an environmental management system. In accordancewith the community system for environmental managementand auditing, the public will be informed about the company’senvironmental policy at these sites:Albert Ackermann GmbH + Co. KG, Albertstraße 4–8, 51643 Gummersbach – Register Number: DE-S-142-00005Albert Ackermann GmbH + Co. KG, Wehrstraße 2, 51645 Gummersbach – Register Number: DE-S-142-00004
Albert Ackermann GmbH + Co. KGD-51641 Gummersbach
Telephone (02261) 83-0 • Fax 83539www.ackermann.com
ComputerisedNurse Call Systems
clino opt® and clino phon®
clino opt® and clino phon® are trade-marked products of Albert Ackermann GmbH + Co. KG
EC-SYSTEMFOR
ENVIRONMENTALMANAGEMENT
AND AUDITING
4
System overview
Centralcommunication unit
Multiplepush button
Call push button
Call push button
Pull cord
Paging system
Nurse call server
Sprechen Hilfsprogramme Konfiguration Service Benutzer
Lichtrufserver Programm
Störungen
Flash-Prom
Kommunikation...
Schnittstelle...
PRZ Befehl...
keine AW 2
PRZ 1
PRZ 2
PRZ 3
PRZ 4
PRZ 5
NOTRUF 103:B ZT 95NOTRUF 103:B ZT 95RUF 103:B ZT 95
103 : B
......................
...... 01 100 AAACKERMANN
..
Information display
Nurse call control unit
Electronic module
Patient handset
Wall interface
Master station
LAN
Centralcommunication unit
Operating Computer
Room terminal
Multiple push button
Operating Computer
Pull cord
Call push button
Call/cancel push button
Room terminal
ACKERMANN clino phon
ZONELINKING
SELECTPATIENT
ASSIST.HNO 312 : A
BATHROOMSTA.BATHROOM
CALLHNO 355 : B
PRES.1DUTY ROOM
ASSIST. 01 102 : A
CONVERSATION
ASSIST. 01 102 : A
CONVERSATION
ASSIST. 01 102 : A
CONVERSATION
ASSIST. 01 102 : A
CONVERSATION
Nurse call control unit
Electronic module
Call push button and call units
Pluggable call units
Cancel push button
Patient handset
Operating computer WIN
Patient terminal
Telephone connection components
Backboxes with accessories
Frames
5
Key symbols / table of contents
Information display
pageSystem overview 4Key symbols / table of contents 5System description WIN / HS 6
Nurse call control unit – PRZ – 12Wall housing 13Printed card board set 13Nurse call server 14Operating computer WIN 15Operating computer HS 16Network distributor, modem, printer 17Central communication unit 18Power supply, wall bracket 19UPS module 20Single-phase safety transformer 20Circuit breaker unit 20Dual zone control unit 21
Electronic module for rooms without speech facility 24Corridor lamp, direction lamps 25Informations display 26Ceiling mounting set 26Zone indicator lamp 27Interface unit, data amplifier, amplifier unit 28
Room terminal – ZT 95, ZT 95 I – 30Connection board for room terminal 32Room electronic – ZE 4/8 – 33Connection board for room electronics 34Patient handset 35Patient terminal 36Headphones 37Wall interface electronics, telecommunication connection socket 38TV control units 39Swivel arm 39Handset 40Loudspeaker, spacer unit, interface unit 41Call push button, doctor call push button 42Call push button with socket 42Pull cord 43Pneumatic call push button 43Call unit as socket 43Call units 44Pear push button, multiple push button 45Auto-release plug system 46Noise level sensor 46Pneumatic pear push button 46Call/Cancel push button, cancel push button 47Cancel push button, touch sensitive push button 48Backbox for touch sensitive push button 48Master station – KSA – 49
System cable 52Mounting frame for cover plate, standard plate 52Headphones 53Radio unit 53Programme selection switch 53Telephone interface unit 54Telecommunication connection box 54Mounting frame for cover plates 54Cover plate 55Backbox 55Cavity wall backbox 55Surface mounting socket 56Light bulb 56
Order numbers 57Offices and agencies 59Overview of all edited Ackermann catalogues 60
Components for energy supply
Master station
Room terminal ZT 95 I
Cover plate
2
879
4
0
3
6
1
5
#*
R
................
............
01 100 AAACKERMANN
..
Telefon-Anschalterelais
Typ 71186 F1
Z A200105U
ACKERMANN
NOTRUF 01 102 : A
GESPRÄCH
ZUSA
PATIENTANWÄHLEN
NOTRUFHNO 312 : A
BAD/WCSTA. BAD
RUFHNO 355 : B
AW 1DIENST
ACKERMANN clino phon
ACKERMANN
6
Computerised Nurse Call System
GeneralAckermann’s computerised Nurse Call Systems have been manufactured to fulfil thepresent valid standards and regulations for light signalling technology (ALT) (DIN VDE0834 part 1 and 2).
System overviewComputerised Nurse Call Systems are microprocessor-controlled systems which utiliseaddress-coded transmission in time division multiplexing mode. Up to 64 physicalzones can be installed with these systems. Each physical zone can be devided up into6 logical sub-zones, this division being realised exclusively by software. For the user, alogical zone represents an independently functioning group. The maximum number ofall logical zones is limited to 240. If more than 128 logical zones are used, the NurseCall Control Unit must be specifically expanded for this purpose. A maximum of 50 users is permitted in a physical zone (exception: only 25 ZE4/8).However, it must be ensured in this case that all devices (e.g. interface units or masterstations) are treated like rooms. The definition of the user address is variable and canbe changed at any time. An WL operating computer or a nurse call server - the mini-mum configuration for a WIN-System - is used to operate the Nurse Call System.
System characteristicsThe Nurse Call Systems is designed for quick and easy installation. The software allowsindividual flexibility, adapting to any changes in the application. For example patient roomnumbers can be quickly changed and allocated during or after installation.
Calls and presences can be displayed at the operating station, in corridors, in dutyrooms and patient rooms. With the speech option the call can be answered from anyone of this points.
Operating the presence push button results in: cancellation of the call within the room,activation of the call transfer and preparation of an emergency call. Existing calls fromother rooms will be transferred to this room.
Systems with a speech facility allow communication from room to room or betweenduty room and the patient. The computerised Nurse Call System can be operated in acentralised, decentralised or combined mode, according to requirements.
The system uses a single six core cable for power supply, speech and data lines.
System description clino opt and clino phon
7
System description clino opt and clino phon
System structureThe computerised Nurse Call System consists of 3 components: the Nurse Call Server (PC),the Nurse Call Control Unit (PRZ),the room equipment.
The Nurse Call Server and the Nurse Call Control Units are independently functional.
Nurse Call ServerThe Nurse Call Server provides the interface between the Nurse Call Control Unit (PRZ)and the operating processors. It manages the existing calls in the system and transfersthem to the processors. An auxiliary database enables the management of configura-tion data such as room numbers and patient specific information.
Operating computerThe operating computer is used as a display unit for the information of the Nurse CallControl Unit (PRZ).
When used with a communication unit and in connection with a speech facility, the ope-rating computer enables general address calls and direct calls to rooms and beds totake place. Calls on the system and staff presences are displayed in graphic or in tabu-lar form.
The operating computer is connected to the Nurse Call Server with a networkedarrangement and therefore has access to the installed database. This information canbe retrieved and processed for administrative purpose.
Nurse Call Control Unit (PRZ)The Nurse Call Control Unit (PRZ) is the main control unit. It is built as a multi-processor unit and comprises of a micro-processor, and audio adapter card (AAK) anda communication processor unit (KPE). Additional control cards can be added accor-ding to requirements.
The control programs and configuration data of the Nurse Call System are loaded bythe WL operating computer or nurse call server (WIN) into the control computer andtransmitted to the communication processor units (KPE) and the audio adapter card(AAK). The communication processor units (KPE) can be exchanged during operation,the required program is being called up automatically by the control computer. If the programs need to be modified or updated, they can be loaded on the Nurse CallControl Unit at any time.
8
System description clino opt and clino phon
Room equipmentThe information in the Nurse Call Systems, e.g. patient calls, can be answered in therooms with the help of various system units. For example, room terminals with a display show pending calls in the order of their priority. If there are no normal, emer-gency or enhanced calls waiting, the remind calls and presences are displayed. Severalcalls with the same priority are scrolled on the display at intervals of about 2 to 3 seconds. The ZT 95 and ZT 95I room terminals also serve as additional callanswering units.
The connection board for the room terminals, electronic elements and the electronicmodule serves as a room distribution board and enables simple wiring of the beds andother fittings in the rooms.
Operating units without speech facility can be installed on the patient beds. Theseinclude, for example, call push buttons (also for pneumatic activation), pull cords, can-cel buttons and call/cancel buttons, pear push- and multiple push buttons, as well aspatient handsets with electro-acoustic transmission.
Nurse Call Systems with intercommunication capability offer the additional option ofinstalling operating units with speech facility. These include, for example, the patienthandset with autorelease plug system for private two-way communication, or the patientterminal with autorelease plug system. In addition to the call function, these operatingunits enable radio/TV and lighting control, as well as private two-way communication.Patient terminals with integrated telephone function and billing system can also beused.
The nurses stations and duty rooms can be equipped with a master station. In addition todisplaying calls and presences, it also permits zone linking. When coupled with thespeech facility, the master station can be used to make general address calls and direc-tly contact rooms or beds.
Following types of calls are indicated:
Call type According to Optical signalsDIN 41050, Part 1
– Patient calls:normal call nurse call (short: call) permanent light – red – bathroom/WC call bathroom or WC call permanent light – white –priority call enhanced call flashing light – red –enhanced enhanced call flashing light – white –bathroom/WC call
– Staff calls:emergency call nurse call with flashing light – red –
emergency call permanent light – green – or/and – yellow –
doctor call doctor call flashing light – white –, red –,– green – and/or yellow –
bathroom/WC (no statement) flashing light - white –emergency call permanent light – green –
or/and – yellow –
– Further calls:diagnostic call diagnostic call flashing light – red –remind call enhanced call flashing light– red –
in memory switching (slow blinking rhythme)telephone call telephone call permanent light telephone
lamp –white–
Only a six-core system cable is required for power supply, speech and data lines. An emergency call is indicated in all zones by the group signal lamps, or on the infor-mation display (with zone linking).
In addition to the visual signal, audible signals are also relayed to all rooms in whichpresences are set. In this context, the Nurse Call Systems distinguish between two callcategories. Category 1 includes normal and bathroom/WC calls. Category 2 includesdoctor, emergency, diagnostic and priority calls, as well as the enhanced bathroom/WCcalls and the bathroom/WC emergency call. When calls are transferred, the Category 1and 2 calls, and the doctor and telephone calls are identified by different signal intervals.
System description clino opt and clino phon
External equipment interfacingThe call system can be extended by adding equipment via the interface. For example,it is possible to connect the paging system such as „clino call“ to the Nurse CallSystem.
Furthermore it is possible to connect internal messages, such as fire alarms or techni-cal alarms via interface units. In WIN-Systems, external information systems can belinked to the Nurse Call System via the local network and correspondingly adaptedprotocols.
SafetyThe Nurse Call System is self monitoring. Any malfunctions are selectively shown oneach display terminal. In the case of a total failure of the Nurse Call Control Unit thesystem operates in an emergency mode and provides call functions, call cancel, pre-sence indication and call transfer to rooms where presence has been set, in addition to thevisual indication of the corridor and zone lamps. In case of power failure, calls remainstored until the power supply is connected again.
An auto-release plug mounted onto a pear or multiple push button as well as on thepatient terminal or patient handset allows a safe disconnection and thus avoids damageto the plug and socket units found in conventional arrangements. When a plug is inad-vertently removed a „plug out“ message is shown on the display units. Lamp outputsare also short-circuit protected. The IP classes indicated in the catalogue refer to thecompletely assembled unit, including cover plates and mounting frames.
Electrical safety and EMC requirements conform to appropiate EC directives.
Maintenance and serviceThe equipment is durable. However it is recommended that the performance of theequipement is verified periodically. Room equipment such as the room terminal and theelectronic modules can be replaced at any time, simply by plugging and unplugging,without interrupting the operation of the system. The servicing of the componentsshould be carried out by a specialist.
A diagnostic function allows the display of information regarding the actual operationalcondition of the system on screen of the operating computer.
A modem can be connected to the operating computer enabling remote diagnosticsand the update of new systems software. This allows capability to diagnose problemsand enables software improvements.
9
10
12
Central devices
Order No.Nurse call control unit – PRZ –as a central control system for control of individual components inthe patient rooms, rooms and corridors. Extendable by modularunits for use of up to 64 zones. Consisting of printed circuit boardset and one or more wall housings.
Equipment for each 16 zones:– wall housing– central control processor– audio-adaptor card– printed circuit board for the loop of up to 16 zones– communication processor units (KPE), each unit controls 2 zones– motherboard with 8 pin connections for
communication processor units (KPE)
Standard system functions:Call type: Designation according to
DIN 41050 Part 1:– Patient calls:
normal call nurse call (abr.: call)bathroom/WC call bathroom- or WC-callpriority call enhanced callenhanced bathroom/WC call enhanced call
– Staff calls:emergency call nurse call with emergency calldoctor call doctor callbathroom/WC emergency call (no statement)
– Further calls:diagnostic call diagnostic callremind call* answered call in remind modetelephone call telephone call
Cancellating and presence call operation:– two presence circuits:
presence 1 / presence 2– combined call cancellation/presence– separate call cancellation for bathroom/WC call– acoustic call transfer– auxiliary answering function*– remote cancelling*– reminder function*
Optical signals:normal call permanent light – red –bathroom/WC call permanent light – white –priority call flashing light – red –enhanced bathroom/WC call flashing light – white –emergency call flashing light – red – and
permanent light – green or yellowdoctor call flashing light – white –, – red –,
– green –, – yellow – bathroom/WC emergency call flashing light – white – and
permanent light – green or yellow diagnostic call flashing light – red – remind call flashing light – red –
(slow flashing rhythm)telephone call telephone light permanently– white – presence 1 permanent light – green – presence 2 permanent light – yellow –
Hands-free speech:– room or individual bed answering*– call to room or individual bed*
* only with nurse call systems with speech facility(clino phon).
13
Central devices
Order No.Nurse call control unit – PRZ –General address calls:– general address to all rooms and zones*– general address presence 1 and/or presence 2*
Further functions:– free selection of zone linking– night transfer– nurse-to-nurse communication from each room to
selected rooms with presence*– self-monitoring and fault message
(according to DIN VDE 0834 application range II)
Operation mode:– decentralised system– centralised system– combined system
* Only with nurse call systems with speech facility (clino phon).
Wall housingfor patient call control unit.
Dimensions: W = 550 mm, H = 550 mm, D = 120 mmColour: black, RAL 9005Material: aluminium
designed for max. 16 zones: 74949 A1 housing 1-16 zones2 housing 17-32 zones3 housing 33-48 zones4 housing 49-64 zones
Printed circuit board setfor installation in one or more wall housings for nurse call controlunit.
with 1 KPE for the connection 1- 2 zones 74949 A1with 2 KPE for the connection 1- 4 zones 74949 A2with 3 KPE for the connection 1- 6 zones 74949 A3with 4 KPE for the connection 1- 8 zones 74949 A4with 5 KPE for the connection 1- 10 zones 74949 A5with 6 KPE for the connection 1- 12 zones 74949 A6with 7 KPE for the connection 1- 14 zones 74949 A7with 8 KPE for the connection 1- 16 zones 74949 A8with 9 KPE for the connection 1- 18 zones 74949 B1with 10 KPE for the connection 1- 20 zones 74949 B2with 11 KPE for the connection 1- 22 zones 74949 B3with 12 KPE for the connection 1- 24 zones 74949 B4with 13 KPE for the connection 1- 26 zones 74949 B5with 14 KPE for the connection 1- 28 zones 74949 B6with 15 KPE for the connection 1- 30 zones 74949 B7with 16 KPE for the connection 1- 32 zones 74949 B8from 17 KPE for the connection of up to 64 zones on request
Central devices
Order No.
14
Sprechen Hilfsprogramme Konfiguration Service Benutzer
Lichtrufserver Programm
Störungen
Flash-Prom
Kommunikation...
Schnittstelle...
PRZ Befehl...
keine AW 2
PRZ 1
PRZ 2
PRZ 3
PRZ 4
PRZ 5
NOTRUF 103:B ZT 95NOTRUF 103:B ZT 95RUF 103:B ZT 95
103 : B
Nurse call server WINor the display and operation, configuration and logging in the com-puterised nurse call system, clino opt and clino phon and as inter-face to external systems such as PSA, EDV, ZLT, etc. Consisting of a computer with multifunctional keyboard, HD, discand CD-Rom drive, streamer, colour monitor.
Equipped with (min.):– PCI ATX-board, Pentium III, 500 MHz– 128 MB RAM– 9 GB fixed disk– 3,5” disk drive– CD-Rom drive– Streamer for 4 - 8 GB– 2 x RS232 interface– parallel interface, e.g. to connect a printer– Hostess 550 multiport interface– Network adaptor (Ethernet 10/100)– 8 MB VGA card– VGA monitor– Keyboard MFII– Mouse
System settings:– Decentralized system– Centralized system– Combined system
Option:Networking with other control computers by means of network adaptor and software via network distributor.
Equipped with user software for the following functions:– System configuration clino opt and clino phon– Call indication in order of priority, type of call and time of call– Indication of call type, zone number, room number and
room attribute (bed, room)– Message presence 1, presence 2– Call answering*– Call cancelling*– Call reminder function*– Calling of rooms and beds*– General adress call to all rooms and zones,
presence 1 and/or presence 2*– Free selection of zone linking– Day/night transfer– Allocation of enhanced calls– Allocation of rooms numbers– Access control via user identification– Control of call forwarding– Self-monitoring and fault message
(according to DIN VDE 0834 application range II)– Service functions– Input and administration of patient data including bed
occupation management– Output of all system data to the connected printer– Organisation and forwarding of calls to the receivers
of the paging system „clino call“
Nurse call server WIN on request
* in combination with central communication unit
Central devices
15
Order No.Nurse call operating computer WINas display and control unit and additionnally as answering unit inconnection with the central communication unit. Consisting of a computer with multifunctional keyboard, HD, diskand CD-ROM drive, colour monitor.
Equipped with (min.):– PCI ATX-board, Pentium II, 400 MHz– 32 MB RAM– 4 GB fixed disk– 3,5” disk drive– CD-ROM drive– 2 x RS232 interface– Parallel interface, e.g. to connect a printer– Network adaptor (Ethernet 10/100)– 8 MB VGA card with Windows accelerator– VGA monitor– Keyboard MFII– Mouse
System settings:– Decentralized system– Centralized system– Combined system
Equipped with user software for the following functions:– Call indication in order of priority, type of call and time of call– Indication of call type, zone number, room number and
room attribute (bed, room)– Message presence 1, presence 2– Call answering*– Call cancelling*– Call reminder function*– Calling of rooms and beds*– General addressing to all rooms and zones,
presence 1 and/or presence 2 – Free selection of zone linking– Day/night transfer– Allocation of enhanced calls– Allocation of rooms numbers– Access control via user identification– Control of call forwarding– Service functions– Input and administration of patient data including bed
occupation management– Output of all system data to the connected printer– Organisation and forwarding of calls to the receivers
of the paging system „clino call“
Nurse call operating computer WIN on request
* in combination with central communication unit
16
Central devices
F1 F2 F3 F4 F5 F6 F7 F8
AW I AW II WartenNächsterRuf Aus Patient
ansprech.Message
PSAErinner.
texte
Rufe Störung Terminal ?
Montag 05.04.1999
Anwesenheiten
Notruf 1 100: A Pat.zim.Bad/WC 1 107 Pat.zim.Ruf 1 109 Pat.zim.Ruf 1 104 Pat.zim.
1 100 Pat.zim.1 107 Pat.zim.
Order No.Nurse call operating computer WLor the display and operation, configuration and logging in the com-puterised nurse call system, clino opt and clino phon and as inter-face to external systems such as PSA, etc. Consisting of a computer with multifunctional keyboard, HD, discand CD-Rom drive, streamer, colour monitor.
Equipped with (min.):– PCI ATX-board, Pentium II, 400 MHz– 32 MB RAM– 4 GB fixed disk– 3,5” disk drive– CD-Rom drive– 4 x RS232 interface– parallel interface, e.g. to connect a printer– 2 x RS422 interface– 8 MB VGA card– VGA monitor– Keyboard MFII– Mouse
System settings:– Decentralized system– Centralized system– Combined system
Equipped with user software for the following functions:– System configuration clino opt and clino phon– Call indication in order of priority, type of call and time of call– Indication of call type, zone number, room number and
room attribute (bed, room)– Message presence 1, presence 2– Call answering*– Call cancelling*– Call reminder function*– Calling of rooms and beds*– General address call to all rooms and zones,
presence 1 and/or presence 2*– Free selection of zone linking– Day/night transfer– Allocation of enhanced calls– Allocation of rooms numbers– Access control via user identification– Control of call forwarding– Self-monitoring and fault message
(according to DIN VDE 0834 application range II)– Service functions– Input and administration of patient data including bed
occupation management– Output of all system data to the connected printer– Organisation and forwarding of calls to the receivers
of the paging system „clino call“
Nurse call operating computer WIN on request
* in connection with central communication unit
17
Central devices
Order No.
Modem and remote maintenance softwarefor quick remote diagnosis and on-site download of new softwareto the nurse call system. Transmission via the telephone network. Connection to the telephone network via telecommunicationsockets.
– Dialling procedure: DTMF or ISDN– Connection to the nurse call server WIN or nuse call operating
computer WL via serial interface– Automatic baud rate identification– Transmission rate: 56 kBit/s or 64 kBit/s– Supply voltage: 220 V ± 10% / 50Hz via plug-in power pack
– Remote maintenance software
Modem and remote maintenance software on request
PrinterConnection via parallel interface to the nurse call server WIN, thenurse call operating computer WIN or the nurse call operating com-puter WL.Supplied with connection cable and manual in German.
Laser printer on request
Network distributorIn the case of a nurse call system with more than one operatingcomputer (WIN), a network distributor is used depending on thetype of connection. The type of network distributor and the connec-tion will vary according to each project. All operating computers aresupplied with system data via a central nurse call server.
Further details on request. on request
18
Central devices
ASSIST. 01 102 : A
CONVERSATION
Order No.Central communication unitwith 2 m long connection cable including 16-pole plug to Allow „hands-free“speech at the operating computer.Dimensions: H = 250 mm, W= 145 mm, D = 35 mmColour: white RAL 9016Material: PC + ABS-FREquipped with:– 1 buzzer– 1 loudspeaker– 1 microphone– 1 doctor call push-button – blue –– 1 call push-button – red – with reassurance lamp– 1 presence push-button – green – with remind lamp – 1 presence push-button – yellow – with remind lamp – 1 push-button for call/remind – white – with conversation
indicator lamp – 1 off push-button - brown –– 1 LED service lamp
Central communication unit without display 76931 HCentral communication unit with display 76941 H
16 pole socketfor connection of the central communication unit, with central plateaccording to DIN 49075.
Dimensions: 71 mm x 71 mmInstallation: in flush box, DIN 49073Colour: pearl white RAL 1013Protection: IP 20
Type:suitable for normally open and normally closed circuit 18785 C
Additional equipment:– suitable mounting frame and cover plate (page 54 and 55)
19
Central devices
Order No.Power supplyfor a constant DC supply of nurse call systems. Compact designthanks to modern primary-clocked circuit technology according toEN 61000-3-2; suitable for top hat rail assembly in the subdistribu-tion or also outside the subdistribution by means of the mountingkit. The supply units are idling, overload and short-circuit-proof.For uninterruptible power supply according to DIN 19240 at 24 Vsee UPS module.
Temperature range and protection classes:– Temperature range: 0 up to +60 °C, with free convection
cooling– Protection class: IP 20– Protective low voltage SELV (according to EN 60950,
VDE 0100 part 410)PELV (according to VDE 0160)
– Protection Class 1 (IEC 536)
Single-phase power supply 89954 M1Nominal output voltage: 24 V +5% -1%Output current: 5 AInput voltage: 85 - 132 VA / 176 - 264 VA
reversibleDimensions: W = 65 mm, H = 125 mm, D = 103 mm
Single-phase power supply 89954 R2Nominal output voltage: adjustable 24 up to 28 VDCOutput current: 10 AInput voltage: 85 - 132 VA / 176 - 264 VA
115/230 ± 15% VACreversible
Dimensions: W = 122 mm, H = 125 mm, D = 103 mm
Single-phase power supply 89954 R3Nominal output voltage: adjustable 24 up to28 VDC Output current: 20 AInput voltage: 85 - 132 VA / 176 - 264 VA
230 ± 15% VACDimensions: W = 227 mm, H = 125 mm, D = 103 mm
Protective cover and mounting kitfor wall-mounting of power supplies outside a subdistribution.Including top hat rail.
Colour: light grey RAL 7035
for 5 A power supply 89954 MA
for 10 A power supply 89954 MB
for 20 A power supply 89954 MC
20
Central devices
ACKERMANN
Order No.Single-phase safety transformerAs the zone and signal lamps can be alternatively operated withAC or DC voltage, a separate supply is recommended in case ofbigger systems.
Protection class 1, splash-proof (VDE 0551)Housing: Steel plate– gray –
Operating voltage:– Input: 230 V / 50 Hz– Output: 24 V / 50 Hz
Power:
250 VA 89957 GDimensions: L = 230 mm, W = 173 mm, H = 145 mm400 VA 89957 HDimensions: L = 230 mm, W = 173 mm, H = 145 mm630 VA 89957 IDimensions: L = 270 mm, W = 225 mm, H = 180 mm
UPS module 24 Vfor uninterruptible power supply according to DIN 19240 at 24 V. Maintenance-free batteries. Matched to the 24 V power supplies of the clino systems.
Technical dataMinimum supply period: 8 minutes at 30 ABattery life using specified charging methods: 8 yearsMaximum output current: 30 ABattery capacity: 12 AhInput voltage: 230 V ~ ± 10%, 50 HzNominal output voltage: 24 VMains voltage switching threshold for battery activation: 190 V ~Battery activation period in case of mains failure: 11 msCharging time for empty batteries to 90 % capacity: 4 hrsProtection class: IP 20Dimensions: L = 310 mm, W = 199 mm, H = 184 mm
UPS module 89954 C5
UPS module 230 Vfor uninterruptible power supply of the nurse call server WIN, the nurse call operating computer WIN and the nurse operatingcomputer WL.
Technical dataOutput : 700 VA / 490 WattOutput voltage: 230 V AC ± 2 %; 50/60 Hz ± 0,1 %Output current 3,0 ASupply time: at 100 % load - 10 minutesInput voltage: 230 V AC; 50/60 HzInput current: 3,5 AAmbiance conditions:– Temperature: 0 °C - 40 °C– Relative humidity of air: 0 - 95 % non-condesingModel:– Stand-alone model 7608903
Dimensions: W = 140 mm, H = 190 mm, D = 440 mm,Weight: 12,5 kg
– 19” built-in unit 76089 ACDimensions: 2 HE, D = 390 mm, Weight: 16,4 kg
21
Central devices
Order No.Dual zone control unitas a central control system for control of individual components inpatient rooms, zones and corridors. The time multiplex transmission(4800 bit/s) is address-coded and comprises parity generators andparity checks circuits in either direction to ensure data integrity. Thesystem software is installed in a wear-resistant EPROM. For use ofup to 2 zones, each with max. 50 rooms.
Structure:Sheet steel housing – black – with connection terminals for directconnection to ring wiring, back-up battery for data memory reten-tion by loss of power (data storage up to one year).
Dimensions: H = 315 mm, D = 60 mm, W = 270 mm
Standard system functions:Call type: According to
DIN 41050 part 1:– Patient calls:
normal call nurse callbathroom/WC call bathroom or WC callenhanced enhanced callbathroom/WC call
– Staff calls:emergency call nurse call with emergency calldoctor call doctor callbathroom/WC (no statement)emergency call
– Further calls:diagnostic call diagnostic callremind call* enhanced call in remind modetelephone call telephone call
Cancelling and presence, call operation:– two presence circuits presence 1 / presence 2*– combined call cancelling/presence– separate call cancelling bathroom/WC call (optional)– acoustic call transfer– auxiliary answering function*– remote cancelling*– reminder function*
Further functions:– room or individual bed answering**– call to room or individual bed**– general address call to all rooms and zones**– general address call to presence 1 and/or presence 2**– nurse-to-nurse communication from each room to selected
rooms with presence*– self-monitoring and fault message
(according to DIN VDE 0834 application range II)*
Dual zone control unit 74945 B
Note: In the case of systems with dual zone control unit, the room electronics – ZE 4/8 – cannot be used.
* In combination with room terminal in nurse call systems with speech facility (clino phon).** In combination with master station in nurse call systems with speech facility (clino phon).
Central devices
22
....................
........ 01 100 AAACKERMANN
..
3
Corridor
Order No.
24
Electronic module for patient rooms without speech facilityThe electronic module for patient rooms without speech facility isthe central control unit for the patient room. It includes all compo-nents for address coded time multiplex transmission, the requiredlogic for selection and data transfer as well as setting of roomcodes. In addition it is fitted with a temporary logic in order to main-tain the function “nurse call” in the case of a fault in the central unitand with short circuit protection.
Call circuits:– doctor call– diagnostic call– bathroom/WC call– patient call as normal call or as emergency call
when presence is set.
Cancel circuits:– presence – green –, for the cancellation of all calls and
presence 1;– separate bathroom/WC cancellation for bathroom/WC
calls with appropriate configuration
Types:
– with corridor lamp (inclusive lamps) 72593 Cinstallation: plug-in in connection boardcolour: white lamp cover
– suitable connection board 72593 Z1dimensions: 158 mm x 110 mm, D = 35 mminstallation: surface-mounting, combined with backbox
DIN 49073colour: plastic base RAL 7040protection: IP 20
– without corridor lamp 7259300installation: plug-in in connection boardcolour: white RAL 9016
– suitable connection board 72593 Z2dimensions: 158 mm x 110 mm, D = 87 mminstallation: surface-mounting, combined with backbox
DIN 49073colour: plastic base RAL 9016protection: IP 20
Corridor
Order No.
25
2-way direction lampvisually indicates the call with the highest priority from the alloca-ted range of a zone. The calls are indicated with different light sig-nals: – Normal call with continuous light– Emergency call with flashing light
Dimensions: 158 mm x 110 mm, D = 87 mmInstallation: surface-mounting combined with backbox DIN 49073Colour: plastic base light grey RAL 7040, with white lamp coverProtection: IP 20
Type (including lamps and connection board):– direction lamp right/left 72594 C
Direction lamp with arrowindicates visually the priority rating of calls on the direction lampfrom the selected section of a zone. Direction lamps display in twodifferent modes: the normal call by a steady light and the emer-gency call by a flashing light.
Dimensions: 158 mm 110 mm, D = 87 mmInstallation: surface-mounting combined with backbox DIN 49073Colour: plastic base light grey RAL 7040, with white lamp coverProtection: IP 20
Type (including lamps and connection board):– direction lamp left 72594 A– direction lamp right 72594 B
Corridor lampFor connection to the room terminal or parallel display for the elec-tronic module.
Dimensions: 158 mm x 110 mm, D = 87 mmInstallation: surface mounting combined with backbox DIN 49073Colour: plastic base light grey RAL 7040, with white lamp coverProtection: IP 20
Type (including lamps):– with 3 lamp sections 72569 C– suitable connection board 72569 Z1– suitable connection board, white RAL 9016 72569 Z3
– with 4 lamp sections 72569 D– suitable connection board 72569 Z2– suitable connection board, white RAL 9016 72569 Z4
Corridor
................
............
01 100 AAACKERMANN
..
................
............
01 100 AAACKERMANN
..
Order No.
26
Ceiling-mounting set for information display complete with cover and suspension kit for ceiling-mounting of thedouble sided information display unit.
Quantity: 2 piecesMaterial: steel (varnished)Colour: white RAL 9010Dimensions Diameter = 13 mm
Length = 300 mm 89603 B1600 mm 89603 B2
Information displaywith red LEDs for luminescent, alphanumerical clear text display,loudspeaker and integrated buzzer.
Functions after system connection:– call indication with zone number, room number
and bed identification– of call type: doctor call, emergency call,
normal calls– audible call transfer and general address call via loudspeaker
Calls are displayed in the following order:– When one or more high priority calls (diagnostic call, emergency
call, bathroom/WC emergency call, enhanced call) are present onthe system, these calls are displayed in turn approx. every 5seconds. Except for the doctor call, an alternating dotted line isset to calls of high priority. The doctor call is indicated by meansof a rapid flashing line under the display.
– Should there be no high priority calls on the system and one ormore bathroom/WC calls or normal calls (nurse calls) are present,these are displayed in turn every 5 seconds.
– If there are no calls of the above-mentioned types, the time willthen be displayed.
Display: 9-digit LED-display
Material: surface mounted aluminium housing, white RAL 9010Dimensions: – for wall mounting:
L = 750 mm, H = 103 mm, D = 35 mm– for ceiling mounting:
L = 750 mm, H = 103 mm, D = 100 mm
Type:– single for wall mounting 74650 B– double-sided for ceiling mounting 74651 B
Corridor
3
3
6
Order No.
27
Zone indicator lamp with one number per cover
Same design as corridor lamp, with one lamp section for each lampcover.
Dimensions: W = 158 mm, D = 87 mm, H = 110 mm each lamp cover
Installation: surface mounting combined with backbox, DIN 49073Colour: plastic base light grey RAL 7040,
with white lamp coverProtection: IP 20
Type (including lamps): 1 lamp cover with the number 1 72515 A22 lamp covers with the numbers 1 and 2 72515 B23 lamp covers with the numbers 1 to 3 72515 C24 lamp covers with the numbers 1 to 4 72515 D25 lamp covers with the numbers 1 to 5 72515 E26 lamp covers with the numbers 1 to 6 72515 F28 lamp covers with the numbers 1 to 8 72515 G2
10 lamp covers with the numbers 1 to 10 72515 H2
Zone indicator lamp with two numbers per cover
Same design as corridor lamp, with two lamp sections for eachlamp cover.
Dimensions: W = 158 mm, D = 87 mm, H = 110 mm each lamp cover
Installation: surface mounting combined with backbox, DIN 49073Colour: plastic base light grey RAL 7040,
with white lamp coverProtection: IP 20
Type (including lamps): 1 lamp covers with the numbers 1 and 2 72515 A32 lamp covers with the numbers 1 to 4 72515 B33 lamp covers with the numbers 1 to 6 72515 C34 lamp covers with the numbers 1 to 8 72515 D35 lamp covers with the numbers 1 to 10 72515 E36 lamp covers with the numbers 1 to 12 72515 F38 lamp covers with the numbers 1 to 16 72515 G3
10 lamp covers with the numbers 1 to 20 72515 H3
Zone indicator lampSame design as corridor lamp, with one lamp section for each lampcover.
Dimensions: W = 158 mm, D = 87 mm, H = 110 mm each lamp cover
Installation: surface mounting combined with backbox, DIN 49073Colour: plastic base light grey RAL 7040, with white lamp coverProtection: IP 20
Type (including lamps): 1 neutral lamp cover 72515 A12 neutral lamp covers 72515 B13 neutral lamp covers 72515 C14 neutral lamp covers 72515 D15 neutral lamp covers 72515 E16 neutral lamp covers 72515 F18 neutral lamp covers 72515 G1
10 neutral lamp covers 72515 H1
Corridor
Order No.
28
Interface unitfor address coded time multiplex transmission including connectionterminals, for connection of zone indicator lamps*, telephoneconnecting relay, etc. The interface unit can also be used as faultmessage module.
Capacity: max. 25 zone indicator lamps/switch contactDimensions: H = 190 mm, W = 110 mm, D = 70 mmInstallation: surface mountingColour: greyMaterial: surface mounted insulating housing
Type:– with 2 potential free switch contacts 72634 A2– with 4 potential free switch contacts 72634 A4
* one interface unit required for each zone.
Data amplifierfor address coded time multiplex transmission, including distributorfor 6-core system cable, for installation in ring mains, when totallength exceeds 400 m per zone.
Dimensions: H = 190 mm, W = 110 mm, D = 70 mmInstallation: surface mountingColour: greyMaterial: surface mounted insulating housing
Type:– fully assembled 72635 D
Amplifier unit*for address coded time division multiplex transfer inclusive switchand reversing automatic operation from ELA to general address, foramplifying the general addresses etc. in corridors and rooms with-out room terminal – ZT 95, ZT 95 I –.
Output: 4 x 5 WattOutput impedance: 4 x 8 OhmDimensions: H = 190 mm, W = 110 mm, D = 70 mmInstallation: flush mountingColour: greyMaterial: flush-mounted insulating housing
Type:– fully assembled 72635 B
* designed for use with Ackermann nurse call systems with speech facility.
2
879
4
0
3
6
1
5
#*
R
ASSIST. 01 102 : A
CONVERSATION
Patient’s room
Order No.
30
ASSIST. 01 102 : A
CONVERSATION
Room terminal – ZT 95, ZT 95 I –General descriptionAssembly in SMD technology, address coded time division multiplextransmission, bypass logic for preservation of the function „nursecall“ in the case of a central control failure, communication amplifierwith speech balance and 5 Watt power amplifier, short-circuit proofedoutputs, communication to room or individual bed.
StructureThe patient room terminal consists of a connection board and aterminal housing containing the electronic components. The termi-nal is simply installed by plugging the housing into the connectionboard by means of the multipoint connector.
Type of connection board– surface mounting– flush mounting– cavity wall mounting
Functions:
– Inputs:8 call circuits: 4 x bed calls
1 x diagnostic call1 x room call1 x bathroom/WC call1 x doctor call
2 presence circuits1 input for separate cancel unit bathroom/WC4 inputs for bed microphones
– Outputs:1 call lamp room4 reassurance lamps at beds1 WC lamp1 doctor call lamp1 presence 1 lamp1 presence 2 lamp1 buzzer1 lamp for conversation1 service LED4 contacts for bed loudspeakers
Information displaydisplay with 32-digit, alphanumeric vacuum fluorescent display forpatient room and zone identification, presence, malfunction, furthercalls and conversations.
Communication inclusive nurse to nurse communication via:– 1 microphone– 1 loudspeaker
Service functionThe existing service function enables the maintenance staff to iden-tify and locate fault messages.
Lamps activation, short circuit proofedThe room terminal is provided with short circuit lamp outputs. Themicroprocessor recognizes the short circuit and signals this to thecentral processor. The fault is immediately logged and the remainingsystem functions retained. A service code appears on both theroom terminal and the display unit. In the case of room terminalwithout display a fault is signalled by intermittent flashing of the ser-vice LED.
Patient’s room
ASSIST. 01 102 : A
CONVERSATION
Order No.
31
Room terminal – ZT 95, ZT 95 I –General descriptionEmergency modeIn the event that no data is obtainable on the data line, the serviceLED flashes, and the fault is indicated on the display (failure of thenurse call central unit). After activating a call push-button, the calllamp is switched on and the call is transmitted to all patient roomswith set presence*. The set call transfer enables identification inemergency operation too.
* The call function is preserved.
Room terminal – ZT 95 I – with display including auxiliary answeringTerminal housing:– without doctor call push-button 76941 B– with doctor call push-button 76941 D
Dimensions: H = 250 mm, W = 145 mm, D = 35 mmColour: white RAL 9016Material: PC + ABS-FR
Equipped with:– 1 buzzer– 1 loudspeaker– 1 microphone– 1 doctor call push-button – blue – (type 76941 D)– 1 call push-button – red – with reassurance lamp – 1 presence push-button – green – with remind lamp – 1 presence push-button – yellow – with remind lamp – 1 push-button answer/remind – white – with conversation lamp– 1 cancel push-button – brown –– 1 LED service lamp– 32 digit alphanumerical vacuum fluorescent display
for following indications:zone, patient room, bed and remind as well as doctor, diagnostic, priority, bathroom/WC, emergency and normal call, presence 1, presence 2, fault, following calls, conversation
Patient’s room
OBENTOP
OBENTOP
ACHTUNGATTENTION
SORGFÄLTIGVERDRAHTEN
Kurzschlußgefahrmit Elektr.- Platine
Order No.
32
Room terminal – ZT 95 –including auxiliary answering Terminal housing:– without doctor call push-button 76934 B– with doctor call push-button 76934 D
Dimensions: H = 250 mm, W = 145 mm, D = 35 mmColour: white RAL 9016Material: PC + ABS-FR
Equipped with:– 1 buzzer– 1 loudspeaker– 1 microphone– 1 doctor call push-button – blue – (type 76931 D)– 1 call push-button – red – with reassurance lamp – 1 presence push-button – green – with remind lamp – 1 presence push-button – yellow – with remind lamp – 1 push-button answer/remind – white – with conversation lamp– 1 cancel push-button – brown –– 1 LED service lamp
Connection board for room terminal – ZT 95, ZT 95 I –with two coding switches for setting room address.
Colour: white RAL 9016
Type:– surface mounting 89150 E2– flush mounting 89150 F2– cavity wall mounting 89150 G2
– Desk-top unit 89153 Bwith 2 m long connecting cable with 16-pole plug
Patient’s room
ASSIST. 01 102 : A
Order No.
33
Room electronic – ZE 4/8 – for rooms without speech facilityAssembly in SMD technology, address coded time multiplex trans-mission, bypass logic for preservation of the function “nurse call“ inthe case of central unit failure, short circuit protected outputs suitablefor 4 or 8 bed call circuits, call and cancellation for each room individu-ally.
StructureThe patient room terminal consists of a connection board and aterminal housing containing the electronic components. The elec-tronic system is simply installed by plugging into the connectionboard by means of the multipoint connector.
Type of connection board– surface mounting– flush mounting– cavity wall mounting
Functions:
– Inputs:8 call circuits: 4 x bed calls
1 x diagnostic call1 x patient room call1 x bathroom/WC call1 x doctor call
2 presence circuits1 input for separate cancel unit bathroom/WC1 input cancellation push-button for all beds4 input cancellation beds or optional4 further bed call circuits
– Outputs:1 call lamp room4 or 8 reassurance lamps for beds1 WC lamp1 doctor call lamp1 presence 1 lamp1 presence 2 lamp1 buzzer1 service LED
Information displayDisplay with 32-digit, alphanumerical vacuum fluorescent display forpatient room and zone identification, presence, malfunction, following calls.
Service functionThe service function provided enables the maintenance staff toidentify and locate the system failure.
Lamp activation, short circuit protectedThe room electronic is provided with short protected lamp outputs.The microprocessor recognizes the short-circuit and signals it to thecentral processor. The fault is immediately logged and the remai-ning system functions are retained. A service code appears on boththe room electronic and the display unit. In the case of room elec-tronic without display the fault is signalled by intermittentflashing of the service LED.
Patient’s room
NOTRUF 01 102 : A
OBENTOP
OBENTOP
ACHTUNGATTENTION
SORGFÄLTIGVERDRAHTEN
Kurzschlußgefahrmit Elektr.- Platine
Order No.
34
Room electronics – ZE 4/8 – for rooms without speech facilityEmergency functionIn the event that no data is available on the data line the service LEDflashes, and the fault is indicated on the display (failure of the nursecall central unit). After activating a call push-button the call lamp isswitched on and the call is transmitted to all patient rooms with setpresence*. In this way calls can also be recognized in emergencyoperation.
Terminal housing:– with display: without doctor call push-button 76941 L
with doctor call push-button 76941 N– without display: without doctor call push-button 76934 L
with doctor call push-button 76934 N
Dimensions: H = 250 mm, W = 145 mm, D = 35 mmColour: white RAL 9016Material: PC + ABS-FR
Equipped with:– 1 buzzer– 1 doctor call push-button – blue – (type 76931 N and type
76941 N)– 1 call push-button – red – with reassurance lamp– 1 presence push-button – green – with remind lamp– 1 presence push-button – yellow – with remind lamp– 1 LED service lamp– 1 socket – 7pole – or
32-digit, alphanumerical vacuum fluorescent display for following indications:zone, patient room, bed and doctor, diagnostic, priority, bathroom/WC, emergency and normal call, presence 1, presence 2, malfunction, following calls
* The call function remains fully operational.
Connection board for room electronics– ZE 4/8 –with two coding switches for setting the room address
Colour: white RAL 9016
Type:– for connection of 4 bed call circuits for
surface mounting 89150 E2flush mounting 89150 F2cavity wall mounting 89150 G2
– for connection of 8 bed call circuits for surface mounting 89150 EBflush mounting 89150 FBcavity wall mounting 89150 GB
Patient’s room
Order No.
35
Patient handset with auto-release plug system*Functions*:
– Nurse call:– call release– private conversation between patient / staff
– Radio and TV:– ON/selection push-button for 4 radio channels– ON/selection push-button for TV-channels (type 74092 A7/H3)– display of the selected channel via LED display– volume control
– Other features:– digital bi-directional data transmission via highly flexible
8-pole connection cable to the wall interface electronics– auto-release plug system depending on the strain on the cable– automatic call release as a normal call when plug ejected from
the auto-release plug system– switch-on reading light
– switch-on room light
Total weight including connection cable and plug: 260 gColour: white RAL 9016Material: ABSProtection: IP 43**
Equipped with:– 1 loudspeaker– 1 microphone– 1 call push-button with orientation light– 4 LED reassurance lights – red –– 2 light push-buttons– 1 radio selection push-button for 4 channels– 1 TV ON/OFF push-button (type 74092 A1)– 1 TV selection push-button (type 74092 A1)– 2 volume controls (+ and –)– 1 socket for connection of a headphone***– 2.5 m connection cable – 8-core – with auto-release plug
Type:– without TV control 74092 A6– with TV control via infrared control unit 74092 A7– without TV control via TV control module 74092 H3
Additional equipment:Cradle for patient handset 74096 CColour: white RAL 9016Material: ABS
* In combination with wall interface electronics page 38.** With plugged jack plug.*** Page 37.
Patient’s room
2
879
4
0
3
6
1
5
#*
R
Order No.
36
Patient terminal with auto-release plug system*and integrated telephone (optional)consisting of a handset and a desk top unit with support andtelephone keypad (optional).
Functions*:
– nurse call:– call release– private conversation between patient/ staff– „hands-free“ conversation per bed patient/ staff
– radio and TV:– ON/selection push-button for 4 radio channels– ON/selection push-button for TV channels
(type 74092 B and type 74092 A)– display of the selected channel via LED display– volume control
– others features:– digital bi-directional data transmission to wall interface
electronics– auto-release plug system, depending on the strain on the cable– automatic call release as a normal call when plug ejected from
the auto-release plug system– switch-on reading light– switch-on of the integrated orientation light
– additional equipement for the option telephone:– participation to telecommunication service– repeat last call – telephone activation by means of the handset– optical und acoustic call indication with
volume control
Handset equipped with:– 1 loudspeaker– 1 microphone– 1 call push-button with orientation light– 4 LED reassurance lamps – red –– 2 light push-buttons– option telephone:
1 light push-button (type 74002 F) or2 light push-buttons (type 74002 H)1 telephone push-button for activating telephone, e.g. for incoming phone calls (type 74002 H)
– 1 radio selection push-button for 4 channels– 1 TV on/off push-button (type 74002 G und type 74002 F)– 1 TV channel selection push-buttons (type 74002 G und type
74002 F)– 2 volumes controls (+ and –)– 1.3 m spiral cable including 1 x WE 8 plugs for the
connection to the desktop unit
Weight (handset): 140 gColour: white RAL 9016Material: ABS
* In connection with wall interface electronics page 38.
Patient’s room
Order No.
37
Patient terminal with auto-release plug system*and integrated telephone (optional)Desk top unit equipped with:– 1 x WE 8 - socket for the connection of the handset– 1 loudspeaker– 1 microphone– 1 auxiliary plug contact for the connection of a pear or
multiple push-button – 7 pole –– 1 auxiliary plug contact for the connection of a
diagnostic device – 6-pole –– 1 socket for connecting a headphone (see below)– 1 orientation lamp 24 V / 5 W– 5 m connection cable with auto-release plug– in addition by the option telephone function:
1 telephone keypad with numbers, telephone activation push-button, repeat last call push-button and light push-button
BZT-registration number: A104293CDimensions: W = 145 mm, L = 228 mm,
H = 65 mm + 20 mm for handsetColour: white RAL 9016Material: ABS, lower part of anodized aluminium
type:
– without telephone function:– without TV control 74002 D2– with TV control via infrared control unit 74002 G3– with TV control via TV control module 74002 G5
– with telephone function:– without TV control 74002 H1– with TV control via infrared control unit 74002 F3– with TV control via TV control module 74002 F5
* In combination with wall interface electronics page 38.
Headphonesfor patient handset, patient terminal, bed control unit and radio unitwith volume control.
Equipped with:– 1 adjustable clip– 2 ear protection sponges for headphones– 3 m connection cable– 1 jack plug (3.5 mm)
Impedance: 32 OhmMaximum capacity: 0.1 WInput: 0.05 WTransmission range: 40 Hz – 15 kHzWeight: 61 g
Headphones 89760 B
Patient’s room
Order No.
38
F
Wall interface electronicsfor use with patient handset and patient terminal*.
Functions:– selection of radio and TV channels – transmission of conversations, data, telephone conversations
and TV channels to and from patient handset/room terminal
Dimensions of the surface housing: H = 182 mm, W = 110 mm, D = 33 mm
Colour: white RAL 9016Material: insulating materials
Equipped with:– 1 call push-button with LED reassurance lamp – red –– 1 7-pole socket for connection of a pear push-button
or multiple push-button– 1 6-pole socket for connection of diagnostic equipment– 1 auto-release plug system for auto-release plug
Type:– for surface mounting without coaxial socket 74190 F5– for installation into bedhead trunking units 74191 F5
Additional equipment:Basesuitable for surface type wall interface electronics type 74190 C
Type:– for surface mounting 88950 A– for cavity wall mounting 88950 B
Frame for flush or cavity wall mounting 88956 BMaterial: insulating materialsColour: white RAL 9016
* The pear push-button ref.-No. 74140 A3 can also be used.
Telecommunication connection socketfor connecting a telephone to bedhead trunking units.
Type:– TAE 6 F 74192 A– WE 8 74193 A
6 = La4 = E3 = Lb
Patient’s room
Order No.
39
TV control unitis the interface between the patient terminal / wall interface and theTV. The signals of the patient terminal for the TV-function on/off andprogramme +/- will be set via contacts in the wall interface. Thecontrol unit changes the signals into special data bits for the TV,which is connected via a SCART-plug.
TV control unit 79813 B
Swivel armwith turning knuckle for patient terminal on the bedside table, adju-stable inclination, adjustable height, swivelling in each direction.
Colour: anodized silverCarrying power: 2.6 kgMaterial: aluminium and polyamid
Type: 2-legs 250/250 mm, with 4 cable clamps 74040 B1
Additional equipment:Fixing device suitable for swivel arm 88988 DAwithout mounting set
Patient’s room
Order No.
40
Handsetwith hook, connection plug – 24-pole – or auto-release plug* and 2 mconnection cable.
Dimensions: W = 50 mm, L = 180 mm, D = 40 mmColour: white/gray beigeMaterial: Insulating materials
Equipped with:– 1 nurse call push-button with nurse symbol– 1 reassurance lamp– 1 light push-button– 1 programme selection switch for 5 radio channels– 1 loudspeaker control unit– 1 socket for connection of a headphones**
Type:– for use in normally open circuit with:
24-pole plug 74022 D7auto-release plug 74022 D6
– for use in normally closed circuit with: 24-pole plug 74023 D7
Additional equipement:Wall bracket for handset 89761 BMaterial: Insulating materials Colour: pearl white RAL 1013
* In combination with auto-release plug system page 46.** Page 37.
Plug system – 24-pole –for connection to handsets with a central plate according to DIN 49075.
Dimensions: 71 x 71 mmInstallation: in flush box DIN 49073Colour: pearl white RAL 1013Protection: IP 20
Type:for normally open and closed circuit 18785 D
Additional equipment:– suitable mounting frame and cover plate (page 54 and 55)
Patient’s room
Order No.
41
Interface unitfor microphone* and loudspeaker.
Dimensions: 71 mm x 71 mmInstallation: in flush box DIN 49073
Interface unit 71049 A
Additional equipment:Cover plate inclusive microphone 88880 F3with auto-latching snap-on mounting,suitable for cover plate frame
Colour: white RAL 9016
* due to acoustical reasons, loudspeaker and microphone are to be mounted withat least a spacer box distance - in the case of combinations use a spacer unit -.
Loudspeaker*with central plate.
Impedance: 50 ΩPower: 0.15 WDimensions: 71 mm x 71 mmInstallation: in flush box DIN 49073Colour: white RAL 9016Protection: IP 20
Loudspeaker 71008 C3
Additional equipment:– suitable mounting frame and cover plate (page 54 and 55)
* due to acoustical reasons, loudspeaker and microphone are to be mounted withat least a spacer box distance - in the case of combinations use a spacer unit -.
Spacer unitto prevent feedback from communication units.
Dimensions: 71 mm x 71 mmInstallation: in back-box DIN 49073
Spacer unit 71197 A
Additional equipement:Cover plate – blind – 88910 A3with auto-latching snap-on mounting,suitable for cover plate frames
Colour: white RAL 9016
Patient’s room
Order No.
42
Call push-buttonDimensions: 71 mm x 71 mmInstallation: in flush box, DIN 49073Protection: IP 40Equipped with: 1 LED reassurance lamp – red –
Type:– suitable for normally open and closed circuit 73022 A
Additional equipment:– cover plate white RAL 9016 with1 call push-button – red – 88881 G3– suitable mounting frame (page 52)
Call push-button: for cover plate design clino opt 90 (not illustrated) 73020 A
Call push-button for doctor callDimensions: 71 mm x 71 mmInstallation: in flush box, DIN 49073Protection: IP 40Equipped with: 1 LED reassurance lamp – red –
Type:– suitable for normally open and closed circuit 73022 A
Additional equipment:– cover plate white RAL 9016 with
1 doctor call push-button – blue – 88881 D3– suitable mounting frame (page 52)
Call push-button: for cover plate design clino opt 90 (not illustrated) 73020 K
Call push-button with socketDimensions: 71 mm x 71 mmInstallation: in flush box, DIN 49073Protection: IP 40
Equipped with: 1 LED reassurance lamp – red –1 7*-pole auxiliary socket
Type:– suitable for normally open circuits 73022 B– suitable for normally closed circuits 73023 B
Additional equipment:– cover plate white RAL 9016 with 1 call push-button – red – 88881 A3– suitable mounting frame (page 52)
Call push-button: for cover plate design clino opt 90 (not illustrated):– normally open circuit 73020 B– normally closed circuit 73021 B
* Independent ground cable is required for connection of noise level sensor
Patient’s room
Order No.
43
Pull cordDimensions: 71 mm x 71 mmInstallation: in flush box, DIN 49073Protection: IP x4Equipped with: 2 m perlon cord with red handle
1 LED reassurance lamp – red –
Type:– suitable for normally open and closed circuit 70046 A3
Additional equipment:– cover plate white RAL 9016 88880 A3– suitable mounting frame (page 52)
Pneumatic call push-buttonDimensions: 71 mm x 71 mmInstallation: in flush box, DIN 49073Protection: IP x4Equipped with: 2 m insulating plastic tube and rubber ball
1 reassurance lamp – red –
Type:– suitable for normally open and closed circuit 70006 A
Additional equipment:– cover plate white RAL 9016 88880 C3– suitable mounting frame (page 52)
Call unit as socketDimensions: 71 mm x 71 mmInstallation: in flush box, DIN 49073Protection: IP 40Equipped with: 1 7-pole socket
Type:– suitable for normally open and closed circuit 73020 C
Additional equipment:– cover plate white RAL 9016 88911 B3– suitable mounting frame (page 52)
Patient’s room
Order No.
44
Call unit as diagnostic socketDimensions: 71 mm x 71 mmInstallation: in flush box, DIN 49073Protection: IP 40
Equipped with:– 1 6-pole socket suitable for diagnostic equipment
for normally open and normally closed circuits 73020 F
– 2 6-pole sockets suitable for diagnostic equipment suitable for normally open circuit 73020 Gsuitable for normally closed circuit 73021 G
Additional equipment:– cover plates white RAL 9016 1 socket 88912 A3
2 sockets 88912 D3– suitable mounting frame (page 52)
Call unit as socketDimensions: 71 mm x 71 mmInstallation: in flush box, DIN 49073Protection: IP 40Equipped with: 2 7-pole sockets
Type:– suitable for normally open circuit 73020 D– suitable for normally closed circuit 73021 D
Additional equipment:– cover plate white RAL 9016 88911 C3– suitable mounting frame (page 52)
Call unit as diagnostic socket/plug contactDimensions: 71 mm x 71 mmInstallation: in flush box, DIN 49073Protection: IP 40Equipped with: 1 7-pole socket
1 6-pole socket suitable for diagnosticequipment
Type:– suitable for normally open and closed circuit 73020 E
Additional equipment:– cover plate white RAL 9016 88912 E3– suitable mounting frame (page 52)
Patient’s room
Order No.
45
Pear push-buttonwith 7-pole connection plug or auto-release plug*, 2 m connectioncable and drop wire for variable looping and strain relief.
Dimensions: W 40 mm, L 110 mm, D 18 mmColour: white RAL 9016
Equipped with: 1 call push-button – red – with nursing staff symbol
1 LED reassurance lamp – red –
Type: – suitable for normally open circuit with: 7-pole plug 74140 A1
auto-release plug 74140 A3
– suitable for normally closed circuit with: 7-pole plug 74141 A1auto-release plug 74141 A3
* In combination with auto-release plug system, page 46.
Multiple push-buttonwith 7-pole connection plug or auto-release plug*, 2 m connectioncable and drop wire for variable looping and strain relief.
Dimensions: W 40 mm, L 110 mm, D 18 mmColour: white RAL 9016Equipped with: 1 call push-button – red –
with nursing staff symbol1 LED reassurance lamp – red –1 light push-button – yellow –
Type: 1 light push-button – yellow –– suitable for normally open circuit with:
7-pole plug 74150 A1auto-release plug 74150 A3
– suitable for normally closed circuit with:7-pole plug 74151 A1auto-release plug 74151 A3
2 light push-buttons – yellow –– suitable for normally open circuit with:
7-pole plug 74152 A1auto-release plug 74152 A3
– suitable for normally closed circuit with:7-pole plug 74153 A1auto-release plug 74153 A3
vielleicht Reihenfolge ändern wie im DEUTSCHEN???
* In combination with auto-release plug system, page 46.
Patient’s room
RUFZEIT PEGELRUF
TEST
ACKERMANNTEST
Order No.
46
Auto-release plug systemfor connection of pear push-button or multiple push-button withauto-release plug, suitable for flush mounting in combination withboxes* and backboxes** with 60 mm screw fixing centre.
Dimensions: 71 mm x 71 mmInstallation: in flush box, DIN 49073Protection: IP 40
Type:– suitable for normally open and normally closed circuit 74199 A
Additional equipment:– cover plate white RAL 9016 88880 D3– suitable mounting frame (page 52)
* Page 54 telephone connecting relay, accessories.** Page 55
Noise level sensorwith adjustable noise detection and time delay facility.
Dimensions: 155 mm x 95 mm, D 38 mmColour: black RAL 9011Equipped with: 1 microphone
1 call push-button – red – 1 push-button for call interlock in order
to test the noise wave2 LED control lights2 m connection cable with 7-pole diode plug
Type:– suitable for normally open and normally closed circuit 73300 B7
Pneumatic pear push-buttonwith 7-pole connection plug.
Colour: whiteEquipped with: 2 m insulating plastic tubes with rubber ball
and retaining clip
Type:– suitable for normally open circuit 70005 A
Patient’s room
Order No.
47
Cancel push-buttonDimensions: 71 mm x 71 mmInstallation: in flush box, DIN 49073Protection: IP 40Equipped with: 1 LED remind lamp – yellow –
1 buzzer for call transfer
Type:– suitable for normally open and normally closed circuit 73642 D
Additional equipment:– cover plate white RAL 9016 with
1 cancel push-button – yellow – 88881 M3– suitable mounting frame (page 52)
Call/cancel push-buttonDimensions: 71 mm x 71 mmInstallation: in flush box, DIN 49073Protection: IP 40Equipped with: 1 LED remind lamp – green –
1 buzzer for call transfer1 LED reassurance lamp – red –
Type:suitable for normally open and normally closed circuit 73642 B
Additional equipment:– cover plate pearl RAL 9016 with 88882 A3
1 call push-button – red –, 1 cancel push-button – green –– suitable mounting frame (page 52)
Call/cancel push-button: for cover plate design clino opt 90 (not illustrated) 73640 B
Cancel push-buttonDimensions: 71 mm x 71 mmInstallation: in flush box, DIN 49073Protection: IP 40Equipped with: 1 LED remind lamp – green –
1 buzzer for call transfer
Type:– suitable for normally open and normally closed circuit 73642 C
Additional equipment:– cover plate white RAL 9016 with 1 cancel push-button – green – 88881 H3– suitable mounting frame (page 52)
Call/cancel push-button: for cover plate design clino opt 90 (not illustrated) 73640 C
Patient’s room
Order No.
48
Touch sensitive push-button
With 4 mm VA cover plate, Ø 70 mm.
Equipped with:– 1 touch sensitive call push-button – 1 LED reassurance lamp – red –
Type:– suitable for normally open and normally closed circuit 71185 D1
Equipped with:– 1 touch sensitive cancel sensor– 1 LED remind lamp – green –
Type:– suitable for normally open and normally closed circuit 71185 D2
Backbox for touch sensitive push-buttonFor flush mounting of touch sensitive call push-button, with backand side entry.
Equipped with:– 1 metal spacer for plaster tolerance– 1 dust cover– 1 gasket– 1 anchor plate
Material: steel, galvanized and chromatized steel
Backbox for touch sensitive push-button 89450 B
Cancel push-buttonDimensions: 71 mm x 71 mmInstallation: in flush box, DIN 49073Protection: IP 40Equipped with: 2 LED remind lamps – green and yellow –
1 buzzer for call transfer
Type:– suitable for normally open and normally closed circuit 73642 E
Additional equipment:– cover plate white RAL 9016 with 88882 B3
2 cancel push-buttons – green and yellow –– suitable mounting frame (page 52)
Cancel push-button: for cover plate design clino opt 90 (not illustrated) 73640 E
Duty room
ACKERMANN clino phon
ZONELINKING
SELECTPATIENT
ASSIST.HNO 312 : A
BATHROOMSTA.BATHROOM
CALLHNO 355 : B
PRES.1DUTY ROOM
Order No.
49
Master station* – KSA –as centralised answering and display unit in the duty room, alterna-tively with or without telephone, including all components foraddress coded time multiplex transmission, the required logic forselection and data transfer, speech amplifier with volume controland 5 W power amplifier, handset for private two-way conversationor telephone calls, short circuit protected lamp outputs for corridornurse call.
Dimensions: W = 345 mm, L = 228 mm, H = 65 mm + 20 mm for receiver
Colour: white RAL 9016Material: moulding material ABS, base of anodized aluminium
Installation: desktop housing including handset (receiver) and 2 m connection cable with 16-pole plug
Functions:– call and status identification with following indications:
zone, patient room, bed, normal call (nurse call), bathroom/WC call, emergency call, bathroom/WC-emergency call, priority call (enhanced call) enhanced bathroom/WC call, diagnostic call, doctor call, answered call in remind function, presence 1, presence 2, failure, following calls, conversation
– call activation– doctor call activation (type 74415 B and type 74416 B)– call reminder position and call cancellation– free selection of zone linking– patient room or individual bed answering– call to room or individual bed– nurse to nurse communication– private conversation staff/patient– simultaneous display of several calls and presences– general address call to all rooms and presences– general address call to presence 1 and/or presence 2– activating functions (e.g. start/end of conversation,
call cancellation, room or bed answering, etc.) only by touching the display screen
– menu index and free allocation of function push-buttons(e.g. general address, night transfer, etc.)
– entering and activation function push-button by touching the monitor
– telephone without mute push-button (type 74416 A and type 74416 B)
Equipped with:– 1 handset (receiver) with loudspeaker, microphone and
microphone “OFF“ push-button– 1 loudspeaker – 1 microphone – 1 nurse call push-button – red – with LED reassurance lamp – 1 doctor call push-button – blue – with LED reassurance lamp
(type 74415 B und type 74416 B)– 2 presence push-buttons – green and yellow – with
LED remind lamps – 1 push-button “answer/remind“ – white – with conversation
display lamp– 1 cancel push-button – brown –– 1 noise level sensor for call transfer– 1 telephone signal lamp– 1 telephone keypad (type 74416 A and type 74416 B) with
telephone activation push-button, digit block, redial push-button and mute push-button
– 1 illuminated graphic LCD display with touch sensitive surface (touch screen)
* for use with Ackermann nurse call systems with speech facility.
Duty room
Order No.
50
16-pole socketfor connection of master station with central plate according to DIN49075.
Dimensions: 71 x 71 mmInstallation: in flush box DIN 49073Colour: pearl white RAL 1013Protection: IP 20
Type:suitable for normally open and closed circuit 18785 C
Additional equipment:– suitable mounting frame and cover plate (page 54 and 55)
Master station – KSA –
Type:– desk top unit without telephone keypad:
without doctor call push-button 74415 Awith doctor call push-button 74415 B
– desk top unit with telephone keypad:without doctor call push-button 74416 Awith doctor call push-button 74416 B
Telefon-Anschalterelais
Typ 71186 F1
Z A200105U
ACKERMANN
Additional equipment
Order No.
52
System cablefor power supply, time multiplex and communication transmission, 6-core cable specification: LIY 2 x 1.5 + I2YV 2 x (2 x 0,6 ST) YFire load: 1200 kJ/m.
Colour: cable sheath – green –
Type halogenfree:– cable drum 100 m 89734 AJ– cable drum 500 m 89734 AH
Standard plateaccording to DIN 49075, suitable for all mounting frame (see above).
Colour: white RAL 9016
Standard plate 88910 B3
Mounting frames for cover platesDesign clino opt 99
Single (Dimensions: 81 mm x 81 mm) 88914 A3Double (Dimensions: 81 mm x 152 mm) 88914 B3Triple (Dimensions: 81 mm x 223 mm) 88914 C3
Colour: white RAL 9016
Additional equipment
Order No.
53
1 2
54
30
Circuit breaker unitfor the use of 4 fuses (maximum 4 A) 20 mm x 5 mm with 4 input-and 8 output terminals
Dimensions: 71 mm x 71 mmInstallation: combination box in flush mounting
order No. 18970 AVColour: white RAL 9016Protection: IP 40
Circuit breaker unit 71188 B
Additional equipment:– cover plate white RAL 9016 88911 L3– suitable mounting frame (page 52)
Radio unitwith volume control and connection for headphones.
Dimensions: 71 mm x 71 mmInstallation: in flush box, DIN 49073Protection: IP 20Equipped with: 1 volume control
1 jack plus socket for the connection of dynamic headphones
Radio unit 73120 H
Additional equipment:– cover plate white RAL 9016 88912 K3– suitable mounting frame (page 52)
Programme selection switchwith mounting plate and expanding retaining clamps suitable forflush mounting in backboxes.
Dimensions: 71 mm x 71 mmInstallation: in flush box, DIN 49073Protection: IP 40Equipped with: 1 programme selection switch for 5 radio
programmes
Programme selection switch 73120 A
Additional equipment:– cover plate white RAL 9016 88912 H3– suitable mounting frame (page 52)
Additional equipment
Telefon-Anschalterelais
Typ 71186 F1
Z A200105U
ACKERMANN
Order No.
54
N
N F N
Telephone interface unitwith time delay for continuous output on receipt of incoming call,cable cap, complete with 0.5 m connecting cable, for pluggableconnection to telephone network.
Dimensions: 71 mm x 71 mmInstallation: in flush boxes, DIN 49073Colour: pearl white RAL 1013Protection: IP 40
Type:– with TAE 6N - plug 71186 F1– with ADo S8 - plug 71186 F2
Additional equipment:– combination box for flush mounting: screw fixing centre 60 mm 18970 AV– combination box for cavity wall mounting: screw fixing
centre 60 mm 18976 A– suitable mounting frame and cover plate (below and page 55)
Mounting frame for cover platesDesign clino opt 90
for telephone interface unit, telecommunication connection box ADo.
Single (Dimensions: 81 mm x 81 mm) 89849 F1Double (Dimensions: 81 mm x 152 mm) 18984 DTriple (Dimensions: 81 mm x 223 mm) 89849 H1
Colour: pearl white RAL 1013
Telecommunication connection boxwith central plate DIN 49075.
Dimensions: 71 mm x 71 mmInstallation: in flush boxes, DIN 49073Colour: pearl white RAL 1013Protection: IP 20
Type:– TAE 6 N KB (upper illustration) 25381 D0– TAE 2x6 NF KB 25382 H0– TAE 2x6/6 NF/F KB 25383 E0– TAE 3x6 NFN KB (central illustration) 25383 F0
Additional equipment:– suitable mounting frame and cover plate (see below and page 55)
Additional equipment
Order No.
55
Cover plateDesign clino opt 90
according to DIN 49075, suitable for mounting frames (page 54).
Colour: pearl white RAL 1013 no clino opt 99 Design
Cover plate 89850 K1
Backbox
according to DIN 49073, for retaining clamps and screw fastening.
Dimensions: Ø 58 mm, D 40 mm
Backbox 18971 A
Cavity wall backboxfor wood, plaster and other cavity walls.
Dimensions: Ø 71 mm, D 65 mmMaterial: thermo plastic, high-flame resistanceFixing centre: 60 mm
Cavity wall backbox 18971 B
Additional equipment
Order No.
56
Surface mounting socketfor the surface mounting of flush mounting units, if required stackable.
Dimensions: 81 mm x 81 mm, D 20,2 mmColour: white RAL 9016
Surface mounting socket 88915 A3
Light bulbfor electronic module, zone indicator lamps and direction lamps.
Colour:clear 88894 Ared 88894 Bgreen 88894 Cyellow 88894 D
Order numbers
57
18785 C 18, 5018785 D 40
18970 AV 5418971 A 5518971 B 5518976 A 5418984 D 54
25381 D0 5425382 H0 5425383 E0 5425383 F0 54
70005 A 4670006 A 4370046 A3 43
71008 C3 4171049 A 41
71185 D1 4871185 D2 4871186 F1 5471186 F2 5471188 B 2071197 A 41
72515 A1 2772515 A2 2772515 A3 2772515 B1 2772515 B2 2772515 B3 2772515 C1 2772515 C2 2772515 C3 2772515 D1 2772515 D2 2772515 D3 2772515 E1 2772515 E2 2772515 E3 2772515 F1 2772515 F2 2772515 F3 2772515 G1 2772515 G2 2772515 G3 2772515 H1 2772515 H2 2772515 H3 27
72569 C 2572569 D 2572569 Z1 2572569 Z2 2572569 Z3 2572569 Z4 25
7259300 2472593 C 2472593 Z1 2472593 Z2 2472594 A 2572594 B 2572594 C 25
72634 A2 2872634 A4 2872635 B 2872635 D 28
73020 A 4273020 B 4273020 C 4373020 D 4473020 E 4473020 F 4473020 G 4473020 K 42
73021 B 4273021 D 4473021 G 44
73022 A 4273022 B 4273023 B 42
73120 A 5373120 H 53
73300 B7 46
73640 B 4773640 C 4773640 E 48
73642 B 4773642 C 4773642 D 4773642 E 48
74002 D2 3774002 F3 3774002 F5 3774002 G3 3774002 G5 3774002 H 37
74022 D6 4074022 D7 4074023 D7 40
74040 B1 39
74092 A6 3574092 A7 3574092 H3 3574096 C 35
74140 A1 4574140 A3 4574141 A1 4574141 A3 45
74150 A1 4574150 A3 4574151 A1 4574151 A3 4574152 A1 4574152 A3 4574153 A1 4574153 A3 45
74190 F5 3874191 F5 3874192 A 3874193 A 3874199 A 46
74415 A 5074415 B 50
74416 A 5074416 B 50
74650 B 2674651 B 26
74945 B 21
74949 A 1374949 A1 1374949 A2 1374949 A3 1374949 A4 1374949 A5 1374949 A6 1374949 A7 1374949 A8 1374949 B1 1374949 B2 1374949 B3 1374949 B4 1374949 B5 1374949 B6 1374949 B7 1374949 B8 13
76934 B 3276934 D 3276934 L 3476934 N 34
76941 B 3176941 D 3176941 H 1876941 L 3476941 N 34
76W0A00 1676W1A00 16
79813 A 39
88880 A3 4388880 C3 4388880 D3 4688880 F3 41
88881 A3 4288881 D3 4288881 G3 4288881 H3 4788881 M3 47
88882 A3 4788882 B3 4888894 A 5688894 B 5688894 C 5688894 D 56
88910 A3 4188910 B3 5288911 B3 4388911 C3 4488911 L3 20
88912 A3 4488912 D3 4488912 E3 4488912 H3 5388912 K3 53
88914 A3 5288914 B3 5288914 C3 52
88915 A3 56
88950 A 3888950 B 3888956 B 38
88988 DA 39
89150 E2 32, 3489150 F2 32, 3489150 G2 32, 3489150 EB 3489150 FB 3489150 GB 34
89153 B 32
89450 B 48
89603 B1 2689603 B2 26
89734 AH 5289734 AJ 52
89760 B 37, 5389761 B 40
89849 F1 5489849 H1 5489850 K1 55
89954 C5 2089954 M1 1989954 M2 1989954 M4 1989954 MA 1989954 MB 1989954 MC 19
89957 E 2089957 F 2089957 G 2089957 H 2089957 I 2089957J 20
Order No. Order No. Order No. Order No.Page Page Page Page
Ackermann Spain
2000 Ackermann Ibérica S.L.C/ Sierra de Guadarrama, 32 A + BE-28850 San Fernando de Henares(Madrid)Telephone: (+34 91) 6 77 82 03Fax: (+34 91) 6 77 86 25
Office BarcelonaTelephone: (+34 93) 4 90 63 88Fax: (+34 93) 4 91 51 06
Office BilbaoTelephone: (+34 94) 4 33 18 00Fax: (+34 94) 4 33 79 26
OfficeSevillaTelephone: (+34 95) 4 23 41 18Fax: (+34 95) 4 23 41 52
Ackermann France
Systèmes de Distribution Electriqueet de CommunicationZone Industrielle F-68190 Ensisheim (Haut Rhin) Telephone: (+33 3) 89 83 47 00Fax: (+33 3) 89 81 09 98
Office Paris15, rue du Premier MaiF-92752 Nanterre CedexTelephone: (+33 1) 47 85 51 00Fax: (+33 1) 47 85 97 10
Ackermann Great Britain
Ackermann Ltd.Michigan Drive, Tongwell, Milton KeynesGB-MK15 8HQTelephone: (+44 19 08) 61 17 80Fax: (+44 19 08) 61 80 66
Ackermann Sweden
Albert Ackermann ABStora Pukevägen 12S-43370 SävedalenTelephone: (+46 31) 3 40 80 85Fax: (+46 31) 3 40 80 89
Office StockholmTelephone: (+46 8) 7 49 61 02Fax: (+46 8) 7 49 61 07
Ackermann Poland
ul. Al Krakowska 104PL-05-090 Raszyn Sekocin StaryTelephone: (+48 22) 7 57 96 93
Ackermann Far East
Ackermann Pacific Ltd.Suite 604, Lyndhurst Tower1 Lyndhurst TerraceCentral, Hong KongTelephone: (+852) 28 77-16 18Fax: (+852) 28 77-17 38
Albert Ackermann (S.E.A) Pte Ltd75 Kaki Bukit Industrial TerraceSingapore 416155Telephone: (+65) 8 42 83 60Fax: (+65) 8 42 83 61
Ackermann Middle East FZE
P.O.Box 18100Jebel Ali, Dubai, U.A.E.Telephone: (+971) 4 81 87 89
(+971) 5 06 58 17 52Fax: (+971) 4 81 21 82
Ackermann of North America
Frank J. Stiene100 Winston Drive, P.O.Box 689USA-Cliffside Park, New Jersey 07010Telephone: (+1 2 01) 224-3398Fax: (+1 2 01) 224-8171
Berlin
Albert Ackermann GmbH + Co. KG Halemweg 1913627 Berlin Telephone: (0 30) 38 38 04-0Fax: (0 30) 3 82 89 10
Dresden
Albert Ackermann GmbH + Co. KGKönigsbrücker Straße 6901099 DresdenTelephone: (03 51) 8 29 16-0 Fax: (03 51) 8 29 16-89
Duesseldorf
Albert Ackermann GmbH + Co. KGPostfach 15 01 0340078 DüsseldorfGumbertstraße 18940229 DüsseldorfTelephone: (02 11) 9 21 00-0Fax: (02 11) 9 21 00-11
Essen
Albert Ackermann GmbH + Co. KGNatorpstraße 2745139 EssenTelephone: (02 01) 8 20 96-0Fax: (02 01) 8 20 96-20
Frankfurt/Main
Albert Ackermann GmbH + Co. KG Seelenberger Straße 2 60489 Frankfurt Telephone: (0 69) 24 78 18-0Fax: (0 69) 7 89 58 50
Hamburg
Albert Ackermann GmbH + Co. KG Alsterdorfer Straße 262 22297 Hamburg Telephone: (0 40) 51 48 43-0Fax: (0 40) 51 49 33 30
Office RostockAlbert Ackermann GmbH + Co. KG Warnowallee 2818107 Rostock Telephone: (03 81) 7 61 14 30Fax: (03 81) 7 61 14 32
Hanover
Albert Ackermann GmbH + Co. KGMecklenheidestraße 3430419 HannoverTelephone: (05 11) 9 79 90-0Fax: (05 11) 9 79 90-90
Leipzig
Albert Ackermann GmbH + Co. KGBraunstraße 2204347 LeipzigTelephone: (03 41) 2 45 19-0Fax: (03 41) 2 45 19-19
Office ErfurtAlbert Ackermann GmbH + Co. KG Eugen-Richter-Straße 4599085 ErfurtTelephone: (03 61) 5 66 13 16Fax: (03 61) 5 66 13 27
Ackermann-Group of Companies
Offices and Agenciesin Germany
International Competencein Electrical Installationsand Communications Technology
58
Ackermann-Head Office Gummersbach
Albert Ackermann GmbH + Co. KGPostfach 100151, D-51601 GummersbachAlbertstraße 4–8, D-51643 GummersbachTelephone: (+49 22 61) 83-0Fax: (+49 22 61) 8 33 58Internet http://www.ackermann.com
ORGUM clino serv ® GmbH
Gesellschaft zur Montage und Wartungvon KommunikationsanlagenAlbertstraße, D-51643 GummersbachTelephone: (+49 22 61) 2 10 52Fax: (+49 22 61) 6 59 13
Argentina
ATQ S.R.L.Mitre 337 Piso 6 Dpto. A – B1832 Lomas de ZamoraRA-Pcia. Buenos AiresTelephone: (+54 11) 42 92 56 67/
(+54 11) 42 44 31 53Fax: (+54 11) 42 44 46 12
Australia
Cable Management Systems15 Harker StreetBurwoodAU-Victoria 3125Telephone: (+61 3) 98 89 88 33Fax: (+61 3) 98 89 88 44
Austria
Burisch Elektro-SystemtechnikGes. m. b. H.Percostraße 16A-1220 WienTelephone: (+43 1) 2 50 01-0Fax: (+43 1) 2 59 97 02
Belgium
Components Telecommunication andData Technology, Electrical lnstallationSystems:Rogelec, Constructions ElectriquesNieuwevaart 101B-9000 GentTelephone: (+32 9) 2 25 54 06Fax: (+32 9) 2 23 44 10
Bulgaria
Electrical lnstallation Systems:City Design Centre16, Praskova Str.BG-1680 SofiaTelephone: (+3 59) 2 59 02 53Fax: (+3 59) 29 58 15 14
Czech Republic
Ty-net spol.sr.o.Tratová 1CZ-65843 BrnoTelephone: (+42) 05 47 42 23 11Fax: (+42) 05 47 42 23 40
Denmark
Electrical lnstallation Systems:Ib Baastrup APSDronning Olgas Vej 30DK-2000 København FTelephone: (+45 38) 10 21 29Fax: (+45 38) 10 29 69
Egypt
Components Telecommunication andData Technology, Electrical lnstallationSystems:IECInternational Co. for Eng. Works449 Al-Ahram StreetEG-Giza Sq., CairoTelephone: (+20 2) 5 72 55 71Fax: (+20 2) 5 72 53 03
Luxembourg
Jean WagnerEquipement ElectriqueRue de la ForêtL-8065 Helfent-BertrangeTelephone: (+352) 44 15 44Fax: (+352) 45 57 73
Netherlands
Isolectra B.V.Postfach 3 71 00 NL-3005 LC Rotterdam Telephone: (+31 10) 2 85 52 85Fax: (+31 10) 2 85 54 00
NorwaySivilingeniør J.F. Knudtzen A/SBillingstadsletta 97P.O. Box 160N-1360 NesbruTelephone: (+47) 66 98 33 50Fax: (+47) 66 98 09 55
Portugal
Sotécnica Sociedade Electrotécnica SAP.O. Box 2947P-1123-803 LisboaTelephone: (+351) 19 73 70 00Fax: (+351) 19 73 70 05
Slovakia
Ty-net SLOVAKIA spol.sr.o.Nova 134SK-01701 Povazská BystricaTelephone: (+42) 1 82 22 58 02Fax: (+42) 18 22 32 10 84
Slovenia
PRELOG d.o.o.Cesta XIV. divizije 4SLO-2000 MariborTelephone: (+3 86) 62 30 48 10Fax: (+3 86) 62 30 47 60
Switzerland
Components Telecommunication andData Technology:ZidaTech AGFabrikstraße 9CH-4614 HägendorfTelephone: (+41) 6 22 09 60 30Fax: (+41) 6 22 09 60 33
Communication Systems: ESAG Kommunikations-Systeme AGWalchestraße 20CH-8035 ZürichTelephone: (+41 1) 3 60 39 39Fax: (+41 1) 3 60 39 49
Electrical lnstallation Systems:EHB Brüstungstechnik AGAlte Straße 11CH-4665 OftingenTelephone: (+41) 6 27 89 51 10Fax: (+41) 6 27 89 51 19
Thailand
Kommunikations-Systeme: N.P. International (Thailand) Co. Ltd.90/40-43 Premsombat, Phachasongkoch RoadDindang, Bangkok 10320Telefon: (+66 2) 274 5070Telefax: (+66 2) 274 5073
ForeignOffices and Agencies
Greece
Components Telecommunication:P.A. Georgiadis & Co.61 Solomou St.GR-Athens 10432Telephone: (+30 1) 5 22 54 39Fax: (+30 1) 5 23 42 39
Communication Systems:ELETE Ltd.Hellenic Communications Co.53-55, Aghiou Konstantinou Str.GR-Athens 10437Telephone: (+30 1) 5 24 03 56Fax: (+30 1) 5 24 20 67
Hungary
Burisch VillanyszerelesiRendszerek Kereskedelmi KFTSchweidel U 2H-1047 BudapestTelephone: (+36 1) 3 69 06 40Fax: (+36 1) 3 69 57 31
IcelandS. Gudjonsson HF.Audbrekka 9IS-202 KopavogurTelephone: (+354) 5 20 45 00Fax: (+354) 5 20 45 01
IrelandCommunication Systems:Cable and Wireless Ltd.Airton RoadIR-Tallaght, Dublin 24Telephone: (+353 1) 4 59 83 33Fax: (+353 1) 4 59 83 39
Israel
Communication Systems: Barkai Systems 1988 Ltd.5 Krinizi StreetIL-Ramat Gan 52453Telephone: (+972 3) 6 73 62 62Fax: (+972 3) 6 72 27 23
Electrical lnstallation Systems:M.D.E. Import & Marketing Ltd.P.O.B. 5123K. Sharet IL-Holon 58151Telephone: (+972 3) 9 52 12 32/3Fax: (+972 3) 9 52 12 36
Italy
Communication Systems: ABB Elettrocondutture S. p. A.Viale dell’lndustria 18 I-20010 Vittuone (Milano) Telephone: (+39 02) 9 03 41Fax: (+39 02) 90 34 76 13
Jugoslavia
pbe – Inter ContactPozeska 65/A YU-11030 Beograd – SerbienTelephone: (+38) 11 13 54 81 23Fax: (+38) 1 113 54 81 10
Munich
Albert Ackermann GmbH + Co. KGFraunhoferstraße 2282152 Planegg-MartinsriedTelephone: (0 89) 89 56 57-0Fax: (0 89) 8 56 16 36
Nueremberg
Albert Ackermann GmbH + Co. KGPostfach 82 01 2890252 NürnbergSigmundstraße 151/OG.90431 NürnbergTelephone: (09 11) 9 61 12-0Fax: (09 11) 6 58 97 23
Saarbruecken
Albert Ackermann GmbH + Co. KGVorderster Berg 1066333 VölklingenTelephone: (0 68 98) 9 14 71-0Fax: (0 68 98) 9 14 71 29
Subdivision KoblenzTelephone: (02 61) 80 10 27
Stuttgart
Albert Ackermann GmbH + Co. KGPostfach 32 5173752 Ostfildern-KemnatZeppelinstraße 44/173760 Ostfildern-KemnatTelephone: (07 11) 1 67 19-0Fax: (07 11) 1 67 19 29
59
Overview of all edited Catalogues
te li flurCable Management SystemsFloor and Wall Trunking Systems and Accessories
3078
Nurse Call Systemsclino opt 99
Computerised Nurse Call Systemsclino opt and clino phon
24.1
25
Telecommunicationand LAN Components
0410-11
Telecommunication and Data Products
Communication Systems
Installation Systems
Further catalogues specific to British Standards are available on request.
comprising:
30 – EÜK – In-screed underfloor trunking systems
35 – OKA – Open flushfloor trunking systems
35.1 – OKU – Open flushfloor trunking systems
53 – HB – Flushfloor service outlets and underfloor distributors for hollow, cavity flooring
54 – DB – Flushfloor service outlets and underfloor distributors for raised access floors
55 – AIK – Surface mounted cable trunking systems
56 – te li tank – Pedestal service outlets
57 – GES – Flushfloor, depth adjustableservice outlets for trunking systems
63 – VH – Hanging service modules
66 – ISS – Service poles
70 – WIK – Trunking system for wall, parapet and ceiling
78 Accessories
05 EURACOM Euro-ISDNTelecommunications Equipment
60
All rights are reserved. Reproduction in whole or inpart is prohibited without the written consent of thecopyright owner. Our literature is purely advisory and,therefore, we bear no legal responsibility for the infor-mation provided. We reserve the right to make chan-ges and modifications without prior notification in theinterest of continual improvement of the systems.
Albert Ackermann GmbH + Co. KGAlbertstraße 4–8 · D-51643 Gummersbach
Telefon (0 22 61) 83-0 · Fax (0 22 61) 8 35 39www.ackermann.com
A member of Novar plc
07.9
9/
25 G
B /
2.0
00 /
dD
P
rinte
d in
Ger
man
y©
Ack
erm
ann,
Gum
mer
sbac
h 20
01Pr
inte
d on
env
ironm
enta
lly fr
iend
ly p
aper
usi
ng c
hlor
ine
free
pulp
s.