+ All Categories
Transcript
Page 1: Inhalation Exposure to Nanoparticles

Toxics Use Reduction Institute

Inhalation Exposure to Nanoparticles

Michael J. Ellenbecker, Sc.D., CIH

Toxics Use Reduction Institute

University of Massachusetts Lowell

Page 2: Inhalation Exposure to Nanoparticles

Potential for Exposure

• Workers and the general public may be exposed to airborne nanoparticles– During their manufacture– During their incorporation into devices– During their use– After end-of-life disposal

• Very little is known about the potential for such exposures, and effective measures to control such exposures

Page 3: Inhalation Exposure to Nanoparticles

LOWELL

The NSF Nanoscale Science and Engineering Center for High-rate Nanomanufacturing

Page 4: Inhalation Exposure to Nanoparticles

So

cie

tal I

mp

ac

t a

nd

Ou

trea

ch

Create Nanotemplates:Design, Manufacture

And Functionalize

Use Templates in High Rate Nanomanufacturing

Testbeds: Memory DevicesAnd Biosensor

Re

liab

ility

& D

efe

cts

, an

d M

od

elin

g

Education and Outreach

SocietalImpact

Collaboration andInteraction

CHN Pathway to Nanomanufacturing

Page 5: Inhalation Exposure to Nanoparticles

Potential Exposures

• Nanoparticles– Manufacturing– Compounding– Adding powders to liquids– Particles in liquids

• Chemicals– Adding functionality to C60 and CNT requires

complex chemical reactions– Nanolithography & other techniques for

making templates

Page 6: Inhalation Exposure to Nanoparticles
Page 7: Inhalation Exposure to Nanoparticles
Page 8: Inhalation Exposure to Nanoparticles

Cross-section of alveoli

Shows a very thin (500 nm) separation between blood and air. An SEM image of the alveoli is shown in the inset

Hoet et al. J Nanobiotech 2004.

Page 9: Inhalation Exposure to Nanoparticles

Regional Lung Deposition

Page 10: Inhalation Exposure to Nanoparticles

Airborne Nanoparticle Monitoring

TSI Fast Mobility Particle Sizer (FMPS) Spectrometer Model 3091 (TSI)

• 5.6 to 560 nm, 32 channels

• 1 s cycle time

Page 11: Inhalation Exposure to Nanoparticles

Results: Aerosol Monitoring-Processing

(7) Twin Screw Extruder Layout of Aerosol Measuring Locations:

Background/Breathing zoneDetecting Locations22 inches distance

Source ConcentraionDetection Location3 inches distance- 1st port

Fugitive SourcesDetecting Locations8 inches distance - 3rd port

Fugitive Sources/ SourceDetecting Locations8 inches distance -2nd port

Page 12: Inhalation Exposure to Nanoparticles

Results: Aerosol Monitoring-Processing

(7) Twin Screw Extruder

Source Concentration during Feeding 5% Nanoalumina

2.52860

7.99656

0.41996

3.78688

0

1

2

3

4

5

6

7

8

9

1 10 100 1000Diameter [Dp/nm]

Pa

rtic

le n

um

be

r co

nce

ntr

atio

n

dN

/dlo

g D

p [1

05 pa

rtic

le/c

m3 ]

Separate feeder into 1st port-5%NA Separate feeders into 1st and 2nd ports-5%NA

Premix feeder into 1st port-5%NA [Control-ABS] Separate feeders into 1st and 2nd ports

Page 13: Inhalation Exposure to Nanoparticles

Results: Aerosol Monitoring-Processing

(5) CNT Furnace

Page 14: Inhalation Exposure to Nanoparticles

Results: Aerosol Monitoring-Processing

(5) CNT Furnace CNT Furnace Operation - Experimental and Control Data Comparison

0.0E+00

2.0E+06

4.0E+06

6.0E+06

8.0E+06

1.0E+07

1.2E+07

1 10 100 1000Diameter [Dp/nm]

No

rma

lize

d P

art

icle

Nu

mb

er

Co

nc

en

tra

tio

n

[pa

rtic

le/c

m3 ]

Source conc. during CNT grow- detect on hole [Control]- Source conc. during CNT grow- detect on hole

Breathing zone conc. during operation [Control]- Breathing zone conc. during operation

Page 15: Inhalation Exposure to Nanoparticles

Results: Aerosol Monitoring-Processing

(6) Fullerene Shaking Reaction

Page 16: Inhalation Exposure to Nanoparticles

Results: Aerosol Monitoring-Processing

(6) Fullerene Shaking Reaction Fullerene Vibration Device - Source and Breathing Zone Concentration

[Experimental and Control Data Comparison]

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

1 10 100 1000

Diameter [Dp/nm]

Par

ticle

Num

ber C

once

ntra

tion

dN/d

log

Dp

[10

5 p

artic

le/c

m3]

Source conc during operation [Control] Source conc during operation

Breathing zone conc during operation- 1 meter away [Control] Breathing zone conc during operation- 1 meter away

Page 17: Inhalation Exposure to Nanoparticles

Respirator Performance

• Recent research suggests that the proper respirator may be highly effective against nanoparticles– N100 cartridges – 100% efficient for

nanoparticles, as predicted– N95 cartridges – Pt > 5% for 40 nm particles

at high breathing rates

Page 18: Inhalation Exposure to Nanoparticles

Filtration Mechanisms

Page 19: Inhalation Exposure to Nanoparticles

Boltzman Equilibrium Charge Distribution

• Aerosol particles are charged by random interaction with air ions

• 1 μm particle – 90% charged at any instant

• 40 nm particle – 20% charged at any instant

Page 20: Inhalation Exposure to Nanoparticles

Air Pollution Control Equipment

• HEPA filters likely to be effective

• Cyclones will not work

• Unanswered questions on the efficacy of fabric filters, electrostatic precipitators, and Venturi scrubbers

Page 21: Inhalation Exposure to Nanoparticles

Precautionary Principle

• When there is uncertainty, err on the side of precaution

• For nanoparticles, this means we need to reduce exposure to the lowest possible level

• We are working with the various CHN laboratories to identify control strategies to accomplish this