Modular
Modular
devices
8/10/2019 Modular Automation Ctrl Devices
3/82352
The new range of indicator
lights and push buttons
replaces and expands upon
the whole SV range and is
composed of the following
three families
Indicator Lights in various
colours such as red,
green, orange, blue and
clear.
Push Buttons in various
contact types (NO, NC,
NO+NC in 1 or 2 poles)
and buttons (latching or
impulse) .
Indicator Lights and Push
Buttons, an association ofthe above two solutions.
Modular Devices -Indicators and Push Buttons
New LED technology provides longerlife.
Integrated label holder.Updated and modernisedappearance.
8/10/2019 Modular Automation Ctrl Devices
4/82353
Latching relays 354
Relays 356
Interface relays 356
Contactors& override contactors 357
Low noise contactors 358
Electromechanical anddigital timers selectionguide 359
Electromechanicaltime switches 360
Digital time switches 362
4 channel digitaltime switches 362
Light sensitive switch 364
Light sensitiveprogrammer 364
Presence Detectors 365
Delay timers 367
Time lag switches 368
Emergencylighting module 369
Switch disconnector 374
Trip Free Switches 375
2 way / centre-offchangeovermodular switches 376
Pushbuttons -Impulse 377
Pushbuttons -Latching 378
Indicator lights 381
Transformers,bells and buzzers 381
Analogue voltmeters,ammeters 382
Digital voltmeters 383
Current transformers 385
Selector switchesfor voltmetersand ammeters 386
kiloWatt hour meters 387
Hours counter 387
Control Relays 388
Modular
devices
8/10/2019 Modular Automation Ctrl Devices
5/82354
Latching relays
EPN510
EPN515
EPN525
EPN540
Latching relays 1NO 230 110 16A-250V 1 1 EPN510
48 24 16A-250V 1 1 EPN501
24 12 16A-250V 1 1 EPN513
12 - 16A-250V 1 1 EPN511
8 - 16A-250V 1 1 EPN512
1NC+1NO 230 110 16A-250V 1 1 EPN515
110 48 16A-250V 1 1 EPN516
48 24 16A-250V 1 1 EPN503
24 12 16A-250V 1 1 EPN518
12 - 16A-250V 1 1 EPN519
4NO 230 110 16A-400V 2 1 EPN540
48 24 16A-400V 2 1 EPN548
24 12 16A-400V 2 1 EPN541
2NC+2NO 230 110 16A-250V 2 1 EPN525
24 12 16A-250V 2 1 EPN528
2NO 230 110 16A-250V 1 1 EPN520
110 48 16A-250V 1 1 EPN523
48 24 16A-250V 1 1 EPN526
24 12 16A-250V 1 1 EPN524
12 - 16A-250V 1 1 EPN521
8 - 16A-250V 1 1 EPN522
Designation Type Coil Coil Power Width in I Pack Cat.
VAC VDC Circuit 17.5mm qty. ref.
50/60Hz AC1
3NO+1NC 230 110 16A-400V 2 1 EPN546
Description
For the control of lighting
circuits in private buildings,
small industry buildings and
administration buildings.
Latching relays - operate when
impulsed by a signal voltage.
The impulse can be provided via
a pushbutton or switch. The first
pulse operates the relay and
latches it into its set (opposite)
state, the next operation of the
pushbutton returns the relay into
its reset (original) state.
The latching relays are built to
add on optionally the following
auxiliaries :
- an auxiliary for centralised
ON/OFF control EPN050
- an auxiliary contact for
remote signalling EPN051
- an auxiliary for multi levelled
centralised control EPN052
- an auxiliary for control by
maintained contact EPN053.
Connection capacity
10 rigid cables
6 flexible cables
Conform to standard EN669-1
and EN669-2-2
For technical details
see page 390
A1
A2
1
2
A1
A2
1
2
3
4
A1
A2
1
2
3
4
A1
A2
1
2
3
4
5
6
7
8
A1
A2
1
2
3
4
5
6
7
8
A1
A2
1
2
3
4
5
6
7
8
8/10/2019 Modular Automation Ctrl Devices
6/82355
Latching relays auxiliaries
Designation Voltage supply Width in I Pack Cat.
17.5mm qty. ref.
Auxiliaries for centralised
control
The EPN050 allows the
centralised control of several
light sources which can be
turned on or off simultaneously
the separate switching by
pushing the pushbuttons, which
are connected with the latching
relay, remains possible.
The EPN052 allows a generic
central control of individual
central on/off EPN050
Auxiliary contact
A remote signalling can be
realised with the auxiliary
contact EPN051.
Auxiliary for control by
maintained contact
When control devices with
permanent impulse are
externally driven, e.g. time
switches or limit switches, an
impulse control directly to the
latching relays coil is possible
with the auxiliary contact EP 053.
Connection latching relay +
auxiliary
Several auxiliaries can be
combined with the latching relay.
Connection capacity
10 rigid cables
6 flexible cables
For technical details
see page 392
Auxiliary for 24 to 230V AC 1/2 1 EPN050
centralised control
Auxiliary for 24 to 230V AC 1/2 1 EPN052
multi levelled
centralised control
Auxiliary for 24 to 230V AC 1/2 1 EPN053
control by
maintained contact
Auxiliary contact 2A - 250 V AC 1/2 1 EPN051
EPN050
EPN051
EPN052
EPN053
12 14
11
21 23
22 24
31 33
32 34
12 14
11
Modular
devices
8/10/2019 Modular Automation Ctrl Devices
7/82356
Relays
Interface relays
DescriptionTo interface between low voltage
and very low voltage circuits to
ensure galvanic isolation
between LV and VLV to 4kV.
ApplicationInterface between fire alarm,
burglar alarm and other VLV
systems and main distribution
circuits.
Connection capacity6 rigid cables
4 flexible cables
For technical details
see page 394
Designation Characteristics Width in I Pack Cat.
17.5mm qty. ref.
Interface relays coil voltage : 1 1 EN145
VLV/LV 1 way 10 to 26V AC/DC
output : 1 changeover contact
max. 5A 230V~ -min. 10mA - 12V DC
VLV/LV 1 way coil voltage : 1 1 EN146
230V~ 50Hz
output : 1 changeover contact
max. 5A 230V~
min. 10mA - 12V DC
Relays 1NC+1NO 230V 50Hz 16A-250V 1 12 ER120
24V 50Hz 16A-250V 1 12 ER123
12V 50Hz 16A-250V 1 12 ER124
2NC+2NO 230V 50Hz 16A-250V 2 1 ER135
24V 50Hz 16A-250V 2 1 ER138
12V 50Hz 16A-250V 1 1 ER139
Auxiliary contact 2A-250V 1/2 1 EP071
Designation Type Coil Power Width in I Pack Cat.
Circuit 17.5mm qty. ref.
AC1
Description
To provide command of low
power circuits max 16A;
associated with pushbuttons
switches, time switches etc to
provide for remote control appli-
cations.
The relays will accept an
auxiliary contact for remote
signalling applications.(EP071)
For the command of VLV circuits
use interface relays EN145 and
EN146.
For the command of high power
circuits (25, 40, 63Amps) use
contactors as shown on
page 357.
For technical details
see page 393
ER120
ER138
EN145
A1 1
A2 2 4
A1 1
A2 2 4
8/10/2019 Modular Automation Ctrl Devices
8/82357
Contactors and override contactors
Contactors 1NO 230V 25A-250V 1 1 ES110 ES110A
1NO+1NC 230V 25A-250V 1 1 ES210
110V 25A-250V 1 1 ES216
24V 25A-250V 1 1 ES239
2NO 230V 25A-250V 1 12 ES220 ES220A
40A-400V 3 1 ES240
63A-400V 3 1 ES263
110V 25A-250V 1 1 ES226
24V 25A-250V 1 1 ES224 ES224A
40A-400V 3 1 ES252
63A-400V 3 1 ES262
2NC 230V 25A-250V 1 12 ES230 ES230A
110V 25A-250V 1 1 ES236
3NO 230V 25A-400V 2 6 ES320 ES320A
230V 40A-400V 3 1 ES340
3NO+1NC 230V 25A-400V 2 1 ES444
40A-400V 3 1 ES345
63A-400V 3 1 ES365
4NO 230V 25A-400V 2 6 ES420 ES420A
40A-400V 3 1 ES440
63A-400V 3 1 ES463
110V 25A-400V 2 1 ES426
40A-400V 3 1 ES44663A-400V 3 1 ES466
24V 25A-400V 2 1 ES424 ES424A
40A-400V 3 1 ES442
63A-400V 3 1 ES462
4NC 230V 25A-400V 2 6 ES430 ES430A
40A-400V 3 1 ES480
63A-400V 3 1 ES490
110V 25A-400V 2 1 ES426
40A-400V 3 1 ES436
63A-400V 3 1 ES496
24V 25A-400V 2 1 ES432
63A-400V 3 1 ES492
2NO+2NC 230V 25A-250V 2 1 ES450
63A-250V 3 1 ES470
24V 25A-250V 2 1 ES242
Designation Type Coil Power Width in I Pack Standard Override
AC Circuit 17.5mm qty. cat. ref. cat. ref.
50/60Hz 50/60Hz
Description
Contactors
For the remote switching and
control of power circuits
(25A-63A AC1)
Override contactorsallows : - permanent ON
- permanent OFF
Technical data
The choice of contactor
depends upon a number of
parameters, e.g.
- the nature of the supply.
- the power it is switching.
- the characteristics of the load.
- the control voltage required.
- number of operations
All contactors ratings are for
AC1 loads only if the load
differs from AC1 the contactormay need de-rating
The use of LZ 060
(heat dissipation inserts)
between all contactors
installed or between
contactors and adjacent
devices is recommended.
Options
Contact choice
- normally open (NO)
- normally closed (NC)
LZ 060 heat dissipation inserts.
Auxiliary
25A contactors will accept
auxiliary, EP 071 contact.
For technical details
see pages 393-395
Auxiliary 2A-250V 1/2 1 EP071
Heat dissipation insert 1/2 10 LZ060
ES230
ES320
ES463
1113
1214
1113
1214
Modular
devices
8/10/2019 Modular Automation Ctrl Devices
9/82358
Low Noise Contactors
2 NO 230V 50 Hz 25A - 250V 1 12 ESN220B
40A - 400V~ 3 4 ESN240B
63A - 400V~ 3 4 ESN263B
3 NO 230V 50 Hz 25A - 400V 2 6 ESN320B
40A - 400V~ 3 4 ESN340B
3 NO + 1 NC 230V 50 Hz 25A - 250V 2 6 ESN444B
4 NO 230V 50 Hz 25A - 400V 2 6 ESN420B
230V 50 Hz 40A - 400V~ 3 4 ESN440B
230V 50 Hz 63A - 400V~ 3 4 ESN463B
4 NC 230V 50 Hz 25A - 400V 2 6 ESN430B
Auxiliary Contact 1NO + 1NC 6 A - 250V 1/2 1 ESN071B
Cover for 2 module contactors 2 10 ESN002B
Cover for 3 module contactors 3 10 ESN003B
Designation Type Coil Power Width in I Pack cat. ref
AC voltage circuit AC1 17.5mm qty.
Description
For the remote switching and
control of power circuits
(20A-63A AC1)
Technical data
The choice of contactordepends
upon a number of parameters,
e.g.
The nature of the supply.
The power it is switching.
The characteristics of the load.
The control voltage required.
Number of operations
All contactors ratings are for
AC1
loads only if the load
differs from AC1 the contactor
may need de-rating.
The use of LZ060 (heatdissipation inserts) between all
contactors installed or
between contactors and
adjacent devices is
recommended.
Options
Contact choice
Normally open (NO)
Normally closed (NC)
ESN420B
ESN440B
8/10/2019 Modular Automation Ctrl Devices
10/82359
Time switches and twilight switches selection chart
Analogue time switches (din rail mounted) Analogue time switches (72 x 72mm)
Technical
characteristics EH 010 EH 011 EH 110 EH 111 EH 171 EH 191 EH 710 EH 711 EH 770 EH 771 EH 712 EH 715 EH 716
Width in 1 1 3 3 3 5 - - - - - - -
17.5mm
Voltage 230V 230V 230V 230V 230V 230V 230V 230V 230V 230V 230V 48V DC
supply 110-240VAC
Operating 24 hrs. 24 hrs. 24 hrs. 24 hrs. 7 days 24 hrs./ 24 hrs. 24 hrs. 7 days 7 days 24 hrs. 24 hrs. 24 hrs.
cycle 7 days
Minimum 15 min 15 min 15 min 15 min 2 hrs. 15 min/ 20 min 20 min 2 hrs. 2 hrs. 20 min 20 min 20 min
switching 2 hrs.
Supply failure - 200 hrs. - 200 hrs. 200 hrs. 200 hrs. - 200 hrs. - 200 hrs. - - 200 hrs.
reserve
Manual auto/ auto/ auto/ auto/ auto/ auto/ on/off on/off on/off on/off on/off on/off on/off
override on on on/off on/off on/off on/off
Digital time switches (din rail mounted) Twilight switches
Technical
characteristics EG010 EG071 EG110 EG170 EG103B/E EG171 EG210 EG270 EG203B/E EG470 EE100 EE101 EE110 EE170 EE171
Width in 17.5mm 1 1 3 3 2 3 3 3 2 5 3 3 5 3 3
Operating cycles 24hrs 7days 24hrs 7days 7 days 7days 24hrs 7days 7days 7days - - 24hrs 7days 7days
Program steps 5 20 20 20 56 20 20 20 56 84 - - 15min 1min 1min
Voltage supply 230V 230V 230V 230V 230V 230V 110/ 110/ 230V 230V 230V 230V 230V 230V 230V
& DC 230V 230V
N of channels 1 1 1 1 1 1 2 2 2 4 - - 1 1 1
(pulsed
output)
Analogue time switches
(din rail mounted) :
width in 1 :
EH 010, EH 011
width in 3 :
EH 110, EH 111,
EH 171
width in 5 :
EH 191
Analogue time switches
(72 x 72mm) :
EH 710, EH 711, EH 770
EH 771, EH 712, EH 715
EH 716
Digital time switches
(din rail mounted) :
width in 1 :
EG 010, EG 071
width in 3 :
EG 110, EG 170,
EG 171,
EG 210, EG 270
width in 5 :
EG 470
Twilight switches
(din rail mounted) :
EE 170
Modular
devices
8/10/2019 Modular Automation Ctrl Devices
11/82360
Analogue time switches modular
EH111
EH010
1 channel voltage supply : 230V
daily dial 50/60Hz
without battery reserve output :
1M devices = 1NO 1 1 EH010
16A - 250V AC1
3M devices = 1NO 3 1 EH110
changeover
16A - 250V AC1
Designation Characteristics Width in I Pack Cat.
17.5mm qty. ref.
1 channel voltage supply : 230V
daily dial 50/60Hzwith battery reserve output :
1M devices = 1NO 1 1 EH011
16A - 250V AC1
reserve : 3M devices = 1NO 3 1 EH111
200 hours after being changeover
connected for 120 hours 16A - 250V AC1
1 channel voltage supply : 230V
weekly dial 50/60Hz
with battery reserve output :
1 changeover = 1NO 3 1 EH171
reserve : 16A - 250V AC1200 hours after being
connected for 120 hours
1 channel voltage supply : 230V
daily + weekly dial 50/60Hz
with battery reserve output :
1 changeover = 1NO 6 1 EH191
reserve : 16A - 250V AC1
200 hours after being
connected for 120 hours
Sealable terminal cover kit EH901
for 3 modules time switches
Flush mounting kit for EH902
3 modules time switches
Description
Electromechanical time
switches 1 channel for daily or
weekly programming.
To control lighting, heating,
household appliances, shop
windows etc...
To improve comfort and save
energy.
Applications
Domestic and commercial
premises.
DIN rail mounting
Complies with EN60730
Technical data
- programming by captive
segments.
- manual override :
On 1 module devices :
- automatic
- permanent ON
On 3 and 5 module devices :
- automatic
- permanent ON
- permanent OFF
Minimum switching time:
- 15 min for daily versions
- 2 hours for weekly versions
- 15 min and 2 hours on the
daily+weekly version
Connection capacity :
1 to 4
For technical details
see page 396
8/10/2019 Modular Automation Ctrl Devices
12/82361
Analogue time switches 72 x 72 mm
1 channel daily cycle supply : 230V 50/60Hz
without battery reserve 1 EH710
with battery reserve 1 EH711
economy version 1 EH712
reserve : 200 hours after being
connected for 120 hours
1 channel weekly cycle supply : 230V 50/60Hz
without battery reserve 1 EH770
with battery reserve 1 EH771
reserve : 200 hours after being
connected for 120 hours
1 channel daily cycle supply : 48V
110 to 240V 50/60Hz
without battery reserve 1 EH715
with battery reserve 1 EH716
reserve : 200 hours after being
connected for 120 hours
Designation Characteristics Pack Cat.
qty. ref.
Flush mounting kit EH900
Description
For daily or weekly
programming.
1 channel for the control of
lighting, heating, household
appliances, shop windows etc..
To improve comfort and saveenergy.
Applications
Domestic and commercial
premises.
Complies with EN60730
Technical data
- suitable for surface, flush or
din rail mounting
- programming by captive
segments
- manual override with automatic
return to programme
- operating reserve : 200 hours
after being connected for 120
hours
- output : voltage freechangeover contact 16A/250V
Daily version :
Programming in steps of
10 minutes.
Minimum time between
2 switching intervals : 20 min
Weekly version :
Programming in steps of one
hour.
- minimum time between
2 switching intervals : 2 hours
- switching accuracy : 10 min
For technical details
see page 396
EH770
Modular
devices
8/10/2019 Modular Automation Ctrl Devices
13/82
8/10/2019 Modular Automation Ctrl Devices
14/82363
Astronomical time switches
Astronomical time switch 230V~ , 50Hz 2 1 EE180
1 channel changeover contact
(weekly cycle) 16A AC1
operating reserve
lithium
delivered with key EG005 battery 5 years
Astronomical time switch 230V~ , 50Hz 2 1 EE181
2 channels 2 changeover contacts
(weekly cycle) 16A AC1
operating reserve
lithium
delivered with key EG005 battery 5 years
Designation Characteristics Width in I Pack Cat.
17.5mm qty. ref.
Description
The hager range is composed of
two Astronomical time switches
EE180/EE181
That range offers the following
features :
- Programming of the lighting
interruption
- Automatic change of
winter / summer time
- Astro program and expert
program with individual Astro
program steps
- Programming for day or group
of days (same concept than
our existing clocks with key)
- Anticipation ON
- Maintained ON
- Temporary overrides
- Programming of holidays
period
- Programming via the PC
software and the associated
interface (EG003)
- Weekly program
For technical details
see page 403
EE180
Modular
devices
8/10/2019 Modular Automation Ctrl Devices
15/82364
Twilight switches
Flush cell IP54 for EE100, 101, 110 & 170 1 EE002
Compact light switch 230V~ 50 Hz - 1 EE701
basic 8A normally open contact
(without settings) (cutting phase)
8A AC1
Fix lux : 10...30lux IP55 / Integrated cellFix ON delay : 40s/OFF delay:120s 1000W incandescent
Compact light switch 230V~ 50 Hz - 1 EE702
enhanced 16A normally open contact
(with settings) (cutting phase)
16A AC1
Fix lux : 2 to 1000 lux IP55 / Integrated cell
Time settings : from 1s to 120s 2300W incandescent
Twilight switch 3 1 EE100
delivered with a separate
surface photo electric cell (EE003)
Twilight switch 3 1 EE101
delivered with a separate
flush photo eletric cell (EE002)
Programmable twilight daily cycle 5 1 EE110
switch with surface cell electromech. switch
Programmable twilight weekly cycle 3 1 EE170
switch with surface cell electronical program
8 presetted programs
Programmable twilight weekly cycle 3 1 EE171
switch with surface cell electronical program
free setting
Surface cell IP54 for EE100, 101, 110 & 170 1 EE003
Designation Characteristics Width in I Pack Cat.
17.5mm qty. ref.
Applications
Street lighting, display lighting,
illuminated signes etc....
Connection
protected cable clamps
capacity :rigid : 1.5 to 10mm2
flexible : 1 to 6mm2
on board LED shows status of
changeover contact.
Description
A photo-electric cell measures
the light level and in conjuction
with the relay provides ON / OFF
control of a circuit.
This device controls lighting cir-cuits in relation to ambient light,
based on user settings.
Front cover sealability
Technical data
4 position override switch allow-
ing :
- auto : normal operating mode
- on : permanently switched on
- off : permanently switched off
- test : setting mode for easyadjustement
output : 1 changeover AC1
contact 16A AC1 230V
8A AC1 (EE701)
Maximum distance : 50m
between photocell and controller
Must be used in conjunction
with a suitable rated contactor
For technical details
see page 403
EE110
EE702
EE170
EE002
EE003
8/10/2019 Modular Automation Ctrl Devices
16/82365
An exciting technique
The patented double lens tech-
nique ensures a very precise
detection on 360 of a person
moving on an area up to
13 x 7 m. The integrated
lux-meter makes it also possible
to differentiate the proportion of
natural and artificial light.
Rotating and adaptable
According to the architectural
constraints, the detection zone
can be adjusted with precision
thanks to the rotation of lens on
90.
Override
The command entry on the 2
channel presence detector
(EE811) and on the presence
regulator (EE812) allows the
commutation of a lighting circuit
(for example via a pushbutton).
This facility is ideal for presenta-
tions during which the room must
completely or partially darkened.
When not more presence is detec-
ted the module will return to the
automatic mode after the pre-
selected time delay. Manual dim-
ming is also possible via the same
command entry on the presence
regulator.
Regulation with constant ligh-
ting : nearly a must in all
open-plan offices. The presence
regulator (EE812) adapts the
artificial light depending on
natural light and presence. The
light intensity constantly remains
fixed according to the preselec-
ted set point. An
effective and pleasant lighting
can be carried out easily and
quickly with electronic regulators
or the Hager 1000W dimmer.
Settings : lighting, time delay
and manual dimming. Adjustable
from 5 to 1200 Lux, the ligh-
ting/variation can also be setted
manually via the command entry
on the presence regulator. The
time delay of the lighting and
presence channel can be selec-
ted individually from 30 seconds
to 1 hour.
Basic lighting mode : for safety
in hotels, homes, hospitals and
corridors. The detector will
switch on the lighting channel in
case of presence. The time delay
begins once no more presence
is detected. The light will then be
reduced to the selected value
between 0 and 50%, then
released after 15 minutes for
the EE812 model.
Master and slave : evolutionary
for wide control
The presence detectors can be
connected between them for
corridors or large premises. The
Slave module will for example
detect a presence, inform the
Master module which then com-
mands the light depending on
luminosity, override and duration
of lighting.
Comfortable energy saving with the presence detectors
Benefits :
Models with 1 or 2 channels
Regulators of presence /
light
Detection zone of 360
on 13 x 7 m
Override entry or manual
dimming
Natural and artificial light
measuring
Wide setting possibilities Basic lighting mode on
presence regulators EE812
Master/Slave function
For the control or the regulation of lighting depending on
presence and natural light
The new Hager presence detectors with double lens
technique are adapted to all architectural requirements.
Whether for the regulation of the light depending on occu-
pancy or simply to switch on the lights depending on pre-
sence and ambient luminosity, the Hager presence detectors
offer the necessary flexibility for each application.
Ventilation, ambient temperature or alarms can also be piloted
exclusively by the detection of a movement thanks to the
second channel. A pushbutton connected on the override entry
makes it for example possible to cut the light or reduce it to
the wished level during a presentation.
comprehensivesettings
rectangula r capturezone
natural and a rtificialligh t measure
rotat ing frontlens
Modular
dev
ices
8/10/2019 Modular Automation Ctrl Devices
17/82366
Conventional presence detectors
EE810
EE812
EE813
Presence detector 230V~ 50Hz
1 channel 16A AC1 - 1 EE810
relay output light channel
- lux level and on delay triac output 0.8A
(duration or pulse) defined via
potentiometers
Slave output for association
with EE811/EE812
Lux OFF
Designation Characteristics Width in I Pack Cat.
17.5mm qty. ref.
Presence detector 230V~ 50Hz
2 channels 16A AC1 - 1 EE811 Relay output light channel
- lux level and On delay 230V input 50Hz
define via potentiometers
- input slave / derogation
- 230V input used with push-
button to toggle the light channel
state or with slave in order to
enlarge the detection area
Relay output presence channel 2 A AC1
- on delay presence defined via
potentiometer
Accessory - 1 EE813
mounting accessory for surface mounting
can be used with EE810, EE811, EE812
Presence detector 1/10V 230V ~ 50Hz - 1 EE812 Relay output used to switch 10 A AC1
ON/OFF the electronic ballast
1/10V output used to control an 1/10V 50mA
electronic ballast or Hager
dimmers EV100/EV102
230V input used with push- 230V input 50Hz
button to toggle the channel
or change the setpoint or with
slave in order to enlarge the
detection area
3 functional modes defined via
potentiometers
mode 1 : no regulation
mode 2 : regulation with local setpointvia potentiometer
mode 3 : regulation with setpoint
defined via a remote push button
Description
EE810, EE811 and EE812
High performance presence
detector that will be used in
premises or in passage areas,
where they increase comfort and
reduce drastically the energycosts.
Combination of a presence
area and a motion area. The
presence area is especially inter-
esting in offices, where the
motion area may be used in long
corridors.
Head rotation for detection area
adjustment
Settings via potentiometers
Applications
EE810 - 1 channel detector
Direct control of a light load or
used as a slave for detection
area enlargement.
Lux level and ON delay setting
via potentiometers
Test mode in order to set lux
level and the detection patternEE811 - 2 channels detector
Light relay output for direct
control of a light load
Presence output potential free
relay.
Lux level, on delay setting for
light channel and presence
channel via potentiometers
Input for slave (EE810) and/or
derogation push button.
EE812 - Light regulator 1/10V
Light regulator with 1/10V output
in order to control electronic bal-
lasts and/or Hager dimmers
EV100/EV102. Detector espe-
cially dedicated for energy sav-
ing and comfort purpose.
Input for slave (EE810) and/or
derogation pushbutton in orderto modify the setpoints
Lux level, On delay for light
channel and min level via poten-
tiometers
3 functional modes :
no regulation, regulation with
local setpoint, regulation with
remote setpoint
EE813 : accessory to surface
mounting
For technical details
see page 405
8/10/2019 Modular Automation Ctrl Devices
18/82367
Delay timers
Eingang
Ausgang
T
Eingang
Ausgang
T
Eingang
Ausgang
T
Eingang
Ausgang
T
Eingang
Ausgang
T
EZ001
EZ006
Delay ON 1 c/o contact 1 1 EZ001
10A / 230V~ AC1
time delay T : 0.1s to 10hr
1 Delay OFF 1 c/o contact 1 1 EZ002
10A / 230V~ AC1
time delay T : 0.1s to 10hr
Adjustable time ON 1 c/o contact 1 1 EZ003
10A / 230V~ AC1time delay T : 0.1s to 10hr
Timer 1 c/o contact 1 1 EZ004
10A / 230V~ AC1
time delay T : 0.1s to 10hr
Symmetrical flasher 1 c/o contact 1 1 EZ00510A / 230V~ AC1
time delay T : 0.1s to 10hr
Multifunction 1 c/o contact 1 1 EZ006
6 individual functions 10A / 230V~ AC1
including : time delay T : 0.1s to 10hr
D - delay on
C - delay off
E - adjustable time ON
B - adjustalbe time OFF
A - timerF - symmetrical flasher
- ON
- OFF
Designation Characteristics Width in I Pack Cat.
17.5mm qty. ref.
Description
To provide all types of
automatic control i.e. lighting,
ventilation, watering, machine
pre-heating, automatic door and
visual audible indication, cycle
control etc.
Applications
For timing and automation in
domestic and commercial
premises. The input signal can
be via various switching devices
(pushbutton, latching switch,
timeclock etc.) and the timed
output used to control the
application.
Technical data
Voltage range :
12 & 24 to 48V DC
12 & 24 to 230V AC
Adjustable: time delay from 0.1s
to 10 hours.
LED indicator
complies with EN 60669-2-1
Connection capacity :
6mm2 max flexible
1.5 - 10mm2 rigid
For technical details
see pages 409
58
44
45
EZ003
Modular
dev
ices
8/10/2019 Modular Automation Ctrl Devices
19/82368
Time lag switches
EMN001
Basic staircase time lag switch voltage rating : 230V 50/60Hz 1 6 EMN001
adjustable time delay setting:
30 seconds until 10 minutes
retrigger
16A - 230V AC1
2300 W incandescent
1500 W halogen VLV
10A - 1000 W compact fluorescent
1000 W Fluo mono/duo
460 W Fluo compact
Description Characteristics Width in I Pack Cat.
17.5mm qty. ref.
Multifunction stair case voltage rating : 230V 50/60Hz 2 1 EMN005
time lag switch - basic stair case time lag switch
- pre-warning mode
- double delay mode
30 sec. to 10 min. or 1 hr.
- double delay with pre-warning mode16A - 230V AC1
2300 W incandescent
1500 W halogen VLV
1000 W Fluo mono/duo
460 W Fluo compact
Description
EMN001 and EMN005 time lag
switches to provide control of
lighting circuits with automatic
switch-off after a pre-set time.
(e.g. for staircase, corridors
lighting).The units are of compact with a
2 position switch for permanent/
timed lighting implementation
facility.
1 EMN 005 and EMS 005 incor-
porate a pre-warning of switch
OFF to improve the safety for
users and a double delay func-
tion : 30 sec. to 10 min. or 1
hour by pressing the push- but-
ton more than 3s
For technical details
see pages 411
8/10/2019 Modular Automation Ctrl Devices
20/82369
Emergency lighting module
Application :
for residential and commercial
premises.
Installed in a consumer unit or
distribution board, the lamp can
be configured to light
automatically in the event of
power failure.
It can also be withdrawn from its
base, thereby acting as a mini
torch with an operating duration
of 1 hour 30min.
For technical information
see page 412
Designation Width in I Pack Cat.
17.5mm qty. ref.
Emergency lighting module 3 1 EE960
Designation Characteristics Width in I Pack Cat.
17.5mm qty. ref.
EE960
EE910
power supply :
230 V 50/60 Hz
output supply : 8,4 V ...
time delay for power supply :
24 hours before activation of
remote control
Remote control
to control up to 60 self
contained,
with an average consumption of
0,1 mA / 6 V
4 1
1
EE905
power supply :
230 V 50/60 Hz
output supply : 12 V ...
time delay for power supply :
24 hours before activation of
remote control
Remote control
to control up to 120 self
contained,
with an average consumption of
0,1 mA / 6 V
4 EE910
Remote control for emergency light blocks
The remote control is
recommended in premises for
public and in industrial or
commercial premises.
The device is a 2 position chan-
geover switch, with automatic
recall for switching off or on, of
self contained emergency ligh-
ting, by delivering polarized cur-
rent impulses on the remote
control circuits (+ or -)
Connection capacity :
6 flexible wire
10 rigid wire
For technical information
see page 412
The remote control device
switches self contained emer-
gency lighting into neutral posi-
tion or into working position.
It permits each day after closing
down of premises, to switch off
self contained emergency ligh-
ting to avoid the discharge of
battery.
Modular
dev
ices
8/10/2019 Modular Automation Ctrl Devices
21/82370
Dimmersrange overview
Incandescent/halogen 230V
Halogen VLV (12 or 24V) via electronic
transformer
1/10V control (output only)
fluo with electroballast 1/10V
Input 1/10 V, 50 mA
Halogen VLV (12 or 24V) ferromagne-
tic transformer suitable
for dimming.
The transformer shouldnt be used
with less than 75% of nominal load
dimmers 300 W
EV 011 EV 012
universal dimmers 600 W
EV 002 EV 004
system dimmers
1-10 V pilots
EV 106 EV 108
functioning as a standalone product
0W 20W 60W 100W 300W 600W 1000W
functioning in system : association of dimmers
with 1/10V max 30 x 1kW
EV 011, EV 012EV 002, EV 004
EV 100, EV 102 switch to local position EV 102 + n x EV 100 or EV 102 (slave position)
EV 011
EV 002, EV 004
EV 100, EV 102 switch to local position
EV 012
EV 002, EV 004
EV 100, EV 102 switch to local position
EV 106
EV 102 pilot : switch to master position
EV 102 + n x EV 100 or EV 102 (slave position)
EV 102 pilot : switch to master position
EV 102 + n x EV 100 or EV 102 (slave position)
EV 102 pilot : switch to master position
300 W 600 W 1000 W Pilot 1/10 V
Technical features
EV 011
EV 012
EV 002
EV 004
EV 100 EV 102 EV 106 EV 108
Controls available
- on the product
- external with illuminated pushbutton
- input 1/10 V
- ambient lighting setting
-
yes
-
-
yes
yes
-
1 (EV 004)
yes
yes
yes (slave)
-
yes
yes
yes (slave)
2 levels
yes
yes
-
-
yes
yes
-
2 levels
Types of outputs :
- direct (capacitive/inductive load)
- input 1/10 V
yes
-
yes
-
yes
-
yes
yes (master)
-
yes
-
yes
Functions :
- protection overheating / overloads
- level indicator
- memorisation
- softstart
yes *
-
yes
yes
yes
EV 004
yes
yes
yes
-
yes
yes
yes
yes
yes
yes
yes
yes
yes
-
yes
yes
yes
-
Parameter setting :
- mini, max. level
- dimming speed
- speed at start / stop
- transition speed for level call
-
-
-
-
EV 004
EV 004
EV 004
-
yes
-
-
-
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
system dimmers
universal dimmers 1000 W
EV 100 EV 102
EV 108 with scene inputs
* EV 011 : protection via integrated fuse, electronic protection for other products
8/10/2019 Modular Automation Ctrl Devices
22/82371
Dimmers
EV011
EV004
Designation Characteristics Ref.
Dimmers 300 W
for :
- incandescent 230 V
- halogen 230 V
- VLV halogen lamps with :
ferromagnetic transformer
(inductive load EV 011 )
dimmable electronic transformer
(capacitive load (EV 012 )
20 ... 300 W / VA
230 V / 50 Hz
inductive load
capacitive load
1
1
1
1
1
1
EV011
EV012
Universal remote control dim-
mer 600 W
for :
- incandescent 230 V
- halogen 230 V
- VLV halogen lamps supplied by
ferromagnetic or dimmable elec-
tronic transformer
(cos 0,95)
20 ... 600 W / VA
230 V / 50 Hz
- products with automatic load
recognition
- dimming function
4 EV002
Enhanced universal dimmer
600 W
in addition to EV 002 features :
- min/max level setting- recall mode with pushbutton,
override mode with switch
- scene level setting
0 ... 99 %
4 EV004
Common characteristics :
- Softstart (progressive start) to
increase the working live of
lamps
- memorisation of last dimming
level
- protection against overheating
- control possible by illuminated
pushbutton until 5mA.
The Hager products are suitable
for all light sources : incandes-
cent, LV and VLV halogen, fluo-
rescent with electronic ballast.
Dimming controlled by
push button :
- start/stop by short press
- increasing/decreasing by main-
taining pressure
Dimmer
300 W :
- control by several pushbuttons
- can replace a latching relay
with dimming function
Dimmers 600 and 1000 W :
- universal products with
automatic recognition of the
load
type (inductive/capacitive)
- electronic protection against
overheating and overload
- Indicators :
230 V / overheating / overload
For technical details
see page 413
Width in
17,5 mm
Pack
qty
Modular
dev
ices
8/10/2019 Modular Automation Ctrl Devices
23/82372
For technical details see
pages 413-415
Dimmers
EV100
EV102
Designation Characteristics Ref.
Universal dimmer 1000 W for :
Functional mode selection via
local switch :
- control via pushbutton (local)
- remote control via 1/10V (slave)
Min/Max setting via potentio-
meter
LED indication :
- 230V power supply/load error
- overload / overheating
Load type :
- incandescent
- 230V halogen lamps
- VLV halogen lamps associated
to ferromagnetic transformer
(inductive)
- VLV halogen lamps associated
to electronic transformer (capa-
citive)
230 V/ 50 Hz
20 ...1 000W
1/10V-input
5 1
1
EV100
Universal dimmer 1000 W with
scene inputs
Functional mode selection via
local switch :
- control via pushbutton (local)
- remote control via 1/10V (slave)
- control of the other dimmers via1/10V (master)
Display to show the dim level
and to set the parameters:
- dimming rise time (4s ..99s)
- min dim level (0...49%)
- max dim level (51..99%)
- rise time when switching ON
(1s..99s)
- fall time when switching OFF
(1s..99s)
- scene level
- dimming rise time for each scene
- scene working mode :
recall or override mode
Output contact to display thedim state (load is OFF, contact is
opened, if load is dimmed the
contact is closed)
LED indication :
- 230V power supply / load error
- overload / overheating
Load type :
- incandescent
- 230V halogen lamps
- VLV halogen lamps associated to
ferromagnetic transformer (induc-
tive)
- VLV halogen lamps associated to
electronic transformer (capacitive)
230 V/ 50 Hz
20 ...1 000W
1/10V-input/output
(max. 50mA, 30 EV100 / EV102)
defined via the local switch
Contact output :
1 NO, 250V, 5A
5 EV102
Width in
17.5 mm
Pack
qty
8/10/2019 Modular Automation Ctrl Devices
24/82373
Dimmer system: 1/10V pilots
EV106
EV108
230 V / 50 Hz
1/10V - interface
Output /max 50mA
contact output :
1 NO, 250 V 10 A
Designation Characteristics
Min/max level setting
Contact output for state
information
Dimming rise time setting
Setting of rise time and fall
time
EV 106 and EV 108 pilot
dimmers
To control several dimmers or
electronic ballasts via the 1/10V
output
Display to show the dim level
and for parameter setting
Wiring of illuminated
pushbuttons possible up to
5mA
EV 108 pilot dimmer
Scene inputs used for override
(3 levels) or simple recall
(2 levels).
Use :
to control lighting in meeting and
conference rooms, or in restau-
rants
Dimmers conform to standards :
EN 50081-1, EN 50082-1,
CEI 669-1, CEI 669-2-1.
For technical details
see page 413
1/10V pilot dimmer
To control
EV 100 and EV 102 (max. 30)
To dim electronic ballasts
Wiring of illuminated
pushbuttons possible up to
5mA
Display to show the dim level
and to set the parameters:
- dimming rise time (4 s ..99s)
- min dim level (0..49%)
- max. dim level (51..99%)
Contact output to display the
dim state (load is OFF, contact is
opened, if load is dimmed the
contact is closed). It is used to
switch ON/OFF the electronic
ballast
Width in
17.5 mm
Pack
qty
4 1
1
Ref
EV106
1/10V pilot dimmer with scene
input
In addition to EV106 features :
Scene inputs used for override
(3 levels) or simple recall (2)
For each scene
- dimming rise time
- scene level
- and scene mode
(recall or- override)
4 EV108
Modular
devices
8/10/2019 Modular Automation Ctrl Devices
25/82374
Switch disconnectors
4 x 16A 400V~ 2 1 SB416F SB416
4 x 25A 400V~ 2 1 SB425F SB425
4 x 32A 400V~ 2 1 SB432F SB432
4 x 40A 400V~ 4 1 SB440F SB440
4 x 63A 400V~ 4 1 SB463F SB463
4 x 80A 400V~ 4 1 SB480F SB480
4 x 100A 400V~ 4 1 SB499F SB499
Four pole
Description
For use a switch as a
disconnector in all types of
circuit.
Complies with : EN 60 947-3 all
ratings
Technical data
utilisation category
AC 22B
In : 16, 25, 32A
shrouded cable clamps
connection capacity:
16mm2 rigid conductor
10mm2 flexible conductor
In : 40, 63, (1 pole)
cable clamps,
connection capacity:
25mm2 rigid conductor
16mm2 flexible conductor
In : 80A, 100A
cable clamps
connection capacity:
50mm2 rigid conductor
35mm2 flexible conductor
All switches have a green / red
indication on the handle giving
positive contact indication
use MZN175 as locking device
Designation Characteristics Width in I Pack Cat.
17.5mm qty. ref.
Single pole 1 x 16A 250V~ 1 12 SB116
1 x 16A 250V~ 1 1 SB116V
with pilot light
1 x 25A 250V~ 1 12 SB125
1 x 25A 250V~ 1 1 SB125V
with pilot light
1 x 32A 250V~ 1 1 SB132
1 x 32A 250V~ 1 1 SB132V
with pilot light
1 x 40A 250V~ 1 1 SB140
1 x 63A 250V~ 1 1 SB163
1 x 80A 250V~ 1 1 SB180
1 x 100A 250V~ 1 1 SB199
Double pole 2 x 16A 250V~ 1 12 SB216
2 x 16A 250V~ 1 1 SB216Vwith pilot light
2 x 25A 250V~ 1 12 SB225
2 x 25A 250V~ 1 1 SB225V
with pilot light
2 x 32A 250V~ 1 1 SB232
2 x 32A 250V~ 1 1 SB232V
with pilot light
2 x 40A 250V~ 1 1 SB240
2 x 63A 250V~ 1 6 SB263
2 x 80A 250V~ 1 1 SB280
2 x 100A 250V~ 1 1 SB299
Triple pole 3 x 16A 400V~ 2 1 SB3163 x 25A 400V~ 2 1 SB325
3 x 32A 400V~ 2 1 SB332
3 x 32A 400V~ 3 1 SB332Q
large terminals
3 x 40A 400V~ 3 1 SB340
3 x 63A 400V~ 3 1 SB363
3 x 80A 400V~ 3 1 SB380
3 x 100A 400V~ 3 1 SB399
Designation Characteristics Width in I Pack Cat. ref. Cat. ref.
17.5mm qty. neutral neutral
left right
45
68
44
SB140
SB232 SB240
SB363
8/10/2019 Modular Automation Ctrl Devices
26/82375
Trip free switchesType SA
Designation Characteristics Width in
17,5 mm
Pack
qty
associated auxiliary : auxiliary
contact (AC).
For the main protection in
general or sub-switchboard
* emergency stop
Free tripping disconnector
switch
Allows remote control* tripping
via voltmetric tripping relay to
associate on the left side of
product
Connection capacity for switch :
- 6 to 16 flexible
- 6 to 25 rigid
associated auxiliary :
- 0,5 to 6 flexible
- 1 to 10 rigid
Complies with :
IEC 947-1 and 947-3
AC 23 A
For technical details
see page 420
2 x 40 A 250 V
2 x 63 A 250 V
2 x 80 A 250 V
2 pole switches 2,5
2,5
2,5
1
1
1
Ref.
SA240
SA263
SA280
4 x 40 A 400 V
4 x 63 A 400 V
4 x 80 A 400 V
4 pole switches 4,5
4,5
4,5
1
1
1
SA440
SA463
SA480
Ui = 690 V
Ui = 690 V
SA263
MZ203
MZ206
Shunt trip allows remote tripping
of the trip free switch.
230 - 415V~ 1 1 MZ203
110 - 130V=
24 - 48V~ 1 1 MZ204
12 - 48V=
Under voltage release allows trip free switch to be
closed only when voltage is
above 70% of Un. trip free
switch will automatically trip
when voltage falls by 35% of Un
48V = 1 1 MZ205
230V ~ 1 1 MZ206
Modular
devices
8/10/2019 Modular Automation Ctrl Devices
27/82
8/10/2019 Modular Automation Ctrl Devices
28/82377
Pushbuttons
Pushbuttons without indicator light
impulse 16A - 250V~
contact : 1NO 1 12 SV021
contacts : 2NO 1 12 SV022
contacts : 3NO 1 12 SV025
contact : 1NC 1 12 SV023
contacts : 2NC 1 12 SV024
contacts : 1NO / 1NC 1 12 SV120
contacts : 1NO+1NC 1 12 SV031
contacts : 2 changeovers 1 12 SV026
Pushbuttons with indicator light
impulse
contact: 1NO green 1 12 SV124
contacts: 2 NO red 1 12 SV062
contact: 1 NC red 1 12 SV123
contacts: 2 NC green 1 12 SV064
Designation Characteristics Width in I Pack Cat.
17.5mm qty. ref.
Description
To actuate loads either directly
or via contactors etc.
Technical data
Modular pushbuttons :
- without light
with grey button, red/green
optional
- with light
with red, green button (amber,
blue, colourless, red, green lens-
es on option).
delivered with lamp 230V~, E10
cap.
Options
Pushbuttons can be fitted with
12, 24, 48, 60V lamps (see
below).
Connection capacity :
Shrouded cable clamp type
10 rigid conductor
6 flexible conductor
SV025
SV031
SV062
Modular
devices
8/10/2019 Modular Automation Ctrl Devices
29/82378
Pushbuttons (Latching)
Designation Characteristics Width in I Pack Cat.
17.5mm qty. ref.
Pushbuttons without indicator light
latching 16A - 250V~
contact : 1NO 1 12 SV041
contacts : 2NO 1 12 SV042
contacts : 3NO 1 12 SV047
contacts : 4NO 1 12 SV048
contacts : 1NO+1NC 1 12 SV045
contacts : 2 changeovers 1 12 SV046
Designation Characteristics Width in I Pack Cat.
17.5mm qty. ref.
Indicator green lens 1 12 SVN121
lights
with light 230V~ red lens 1 12 SVN122
orange lens 1 12 SVN123
clear lens 1 12 SVN124
blue lens 1 12 SVN125
red & green double indicator 1 12 SVN126
red triple indicator 1 12 SVN127
Pushbuttons with indicator light
latching
contact : 1NO green 1 12 SV071
contacts : 2NO green 1 12 SV072
Indicator lights
Description
Modular indicator lights
Available with red, green,
amber, blue, colourless lens
Delivered with lamp 230V~,
E10 cap.
62
38
45
Options
Indicator lights can be fitted with
12, 24, 48, 60V lamps (see
below).
shrouded cable clamp type
Connection capacity:
10 rigid conductor.
6 flexible conductor.
SV072
230 V~
8/10/2019 Modular Automation Ctrl Devices
30/82379
Auxiliaries for pushbuttons and indicator lights ...
Supports
for single pushbutton (impulse) 1 6 SW020
(latching) 1 6 SW040
for double pushbutton 1 6 SW030
1 6 SW050
1 6 SW090
for single pushbutton 1 6 SW060
and indicator1 6 SW070
for indicator lights 1 6 SW080
Electrical auxiliaries 16A - 250V~
for pushbuttons
contact : 1NO 12 SW007
contacts : 2NO 12 SW002
contact : 1NC 12 SW003
contacts : 2NC 12 SW004
contact : 1 changeover 12 SW006
contacts : 1NO+1NC 12 SW005
Designation Characteristics Width in I Pack Cat.
17.5mm qty. ref.
Description
This system makes it possible to
build a large range of
pushbuttons and indicator
lamps.
Pushbuttons are built using :
- a base
- the contents
- the lamps
A choice of 6 auxiliary contacts
are available.
The lamp can be selected as
needed.
Indicator lamps :
- the base
- a choice of 5
colours
- 12-230V
Auxiliaries with flashing or test
lamp facility.
Characteristics :
pushbuttons
- 16A AC21 230V~
lamps
12, 24, 48, 60V~ - 0.9W
230V~ neon 0.5W
230V~ fluorescent 0.6W
use fluorescent lamp with blue
and green lenses.
Connection capacity:
10 rigid conductor.
6 flexible conductor.
67
38
45
SW020 SW030
SW070 SW080
SW007 SW002
SW003 SW005
+
Modular
devices
8/10/2019 Modular Automation Ctrl Devices
31/82380
Auxiliaries for pushbuttons and indicator lights
Designation Characteristics Pack Cat.
qty. ref.
Electrical auxiliaries
for indicator lights
test lamp to test a serie of indicator lights 6 SW112
on the same phase
for signal application for one or several indicator lights 6 SW113
End plate 12 SW009
for pushbuttons
Lenses green 12 SW081
for pushbuttons and
indicator lights red 12 SW082
orange 12 SW083
clear 12 SW084
blue 12 SW085
Lamps E10 neon 230V~ 0.5W 20 SW104
for pushbuttons and
indicator lights fluorescent 230V~ 0.6W 20 SW103
incandescent 12V~ 0.9W 20 SW105
24V~ 0.9W 20 SW102
48 & 60V~ 0.9W 20 SW107
Interchangeable (impulse) grey 12 SW017
pushbuttons covers
(latching) grey 12 SW018
green 12 SW015
red 12 SW016
clear 12 SW019
SW112
SW009
SW081 SW082 SW083
SW084 SW085
SW015 SW016 SW019
SW017 SW018
SW104
SW113
8/10/2019 Modular Automation Ctrl Devices
32/82
8/10/2019 Modular Automation Ctrl Devices
33/82382
Analogue voltmeters, ammeters
Voltmeter accuracy : 2% 4 1 SM500
consumption : 2.5VA
0 - 500V
Designation Characteristics Width in I Pack Cat.
17.5mm qty. ref.
Analog ammeters 0 - 5A 4 1 SM005
direct
0 - 15A 4 1 SM015
0 - 30A 4 1 SM030
Ammeters accuracy : 2%
current transformer (CT)
operated
- reading via CT SR 051 scale : 0 - 50A 4 1 SM050
- reading via CT SR 101 scale : 0 - 100A 4 1 SM100
- reading via CT SR 150 scale : 0 - 150A 4 1 SM150
- reading via CT SR 250 scale : 0 - 250A 4 1 SM250
- reading via CT SR 400 scale : 0 - 400A 4 1 SM400
- reading via CT SR 600 scale : 0 - 600A 4 1 SM600
- reading via CT SR 800 scale : 0 - 800A 4 1 SM800
- reading via CT SR 850 scale : 0 - 1000A 4 1 SM850
- reading via CT SR 900 scale : 0 - 1500A 4 1 SM900
- reading via CT SR 910 scale : 0 - 2000A 4 1 SM910
Analogue voltmeters
For domestic and commercial
installations
single phase :
direct connection
three phase :use of a voltmeter selector
switch SK 602 - see page 38
Frequency : 50/60Hz
Connection capacity :
Rigid conductor 10
Flexible conductor 6
Analogue ammeters
For domestic and commercial
installations
Direct reading :
up to 30A
Indirect reading via current
transformers - see page 36
from 50 to 2000A
For technical details,
see page 422
SM500
SM030
8/10/2019 Modular Automation Ctrl Devices
34/82
8/10/2019 Modular Automation Ctrl Devices
35/82384
Digital multimeter
values at the same time, in type
instantaneous, average or
maximum (voltage and intensity
per phase in RMS value).
Multimeter
For monitoring the electrical
network : single, two or three
phases (with or without neutral).
Connection on current
transformer (not provided).
Enables to display 3 electrical
Multimeter - 3 voltmeters : 35 to 480 V
- 3 ammeters per
transformer 0-5 A : 5 to 600 A
- mesure of frequency :
40 to 80 Hz
- hourly metering
For monitoring of power
generator, it measures the
frequency and working time.
For technical details,
see page 423
Designation Width in
17.5 mm
Ref.
4
Pack
qty
1 SM001
Characteristics
SM001
8/10/2019 Modular Automation Ctrl Devices
36/82385
Current transformers (C.T.)
SR051
SR200
Description :
Current transformers are used to
feed analogue and digital
ammeters. As well as kWh
meters.
Their current on secondary
circuit (0-5A) is proportional to
the current on primary circuit
class : 1
can be mounted on copper bar
or on cable
can be mounted on DIN rail with
adaptors
For technical details,
see page 424
Designation Characteristics Width in I Pack Cat.
17.5mm qty. ref.
Current transformers (CT) ratio :
50/5 2,5 1 SR051
100/5 2,5 1 SR101
150/5 3,5 1 SR150
200/5 3,5 1 SR200
250/5 3,5 1 SR250
300/5 4,5 1 SR300
400/5 4,5 1 SR400
600/5 4,5 1 SR600
800/5 5,5 1 SR800
1000/5 6 1 SR850
1500/5 6 1 SR900
2000/5 6 1 SR910
Modular
devices
8/10/2019 Modular Automation Ctrl Devices
37/82386
Selector switches for voltmeters and ammeters
1 pole selector switch 20A 400V~ 3 1 SK600
non spring return
Designation Characteristics Width in I Pack Cat.
17.5mm qty. ref.
2 pole selector switch 20A 400V~ 3 1 SK601
non spring return
Voltmeter selector 20A 400Vac 3 1 SK602
3Ph&N
3 readings between phases
3 readings between phase & neutral
null position (no reading)
Ammeter selector 20A 400Vac 3 1 SK603
4 positions
use in 3Ph&N
reading by phase
null position (no reading)
should be used with current transformer (CT)
Step selector switch 20A 400V~ 3 1 SK604
Key selector switch 10A 400V~ 3 1 SK606
Description
To provide command signals or
program selection in electrical
control schemes
Application
For domestic and commercialinstallations
Connection capacity :
Rigid conductor : 1.5 to 10
Flexible conductor : 1 to 6
Conform to IEC947-3
BS EN 60947-3
Isolating voltage : 500Vac
Nominal current : 10-20A
SK602
SK600
SK603
SK606
2131
2
0
215 731
62
0
33 75
42
2
11
0
31
42
11
0
0
8/10/2019 Modular Automation Ctrl Devices
38/82387
Kilowatt hours meters and hours counter ...
Single phase 230V +/- 20% 50/60Hz
- direct reading 32A single tariff 3 1 EC110
without pulsed output
1 1 EC050
single tariff 3 1 EC111
with pulsed output
1 1 EC051
Single phase 230V 50Hz 3 1 EC120
CT operated 100/5A CT operatedsingle tariff
230V 50Hz 3 1 EC121
100/5A CT operated
dual tariff
Designation Characteristics Width in I Pack Cat.
17.5mm qty. ref.
Three phase 230V/400V 50Hz 7 1 EC310
CT operated 800mA to 80A
single tariff
230V/400V 50Hz 7 1 EC311
800mA to 80A
dual tariff
Three phase 230V/400V 50Hz 4 1 EC320CT operated 50-1500/5A CT operated
single tariff
230V/400V 50Hz 4 1 EC321
50-1500/5A CT operated
dual tariff
Description
Kilowatt hours meters measure
the active energy used in an
electric installation. The range
includes meters with pulsed
output for remote indication or
linking into an energymanagement system.
Kwh meters can be used for
local metering of installation or
monitoring of power
consumption in individual
machines.
Technical data
In accordance to IEC1036,
- with pulse output
100Wh/pulse (except EC110 and
EC050)
- all meters offer part (resettable)
counter and total (nonresettable) counter (except
EC110, EC050 and EC051)
- display with LCD
- accuracy : class II (EC050 and
EC051 class I)
- for CT (current transformers),
see page 385 For technical details,
see pages 426
45
5741
Sealing kit for single phase Kwh meters 1 EC001
direct reading only
(EC 110, EC 111)
EC111
EC051
EC121
Hours counter 230V 50Hz 2 1 EC100
EC100
Modular
devices
8/10/2019 Modular Automation Ctrl Devices
39/82388
Control relays ...
Control relays are used in instal-
lations where the current or the
voltage fluctuation may damage
equipments.
The range is composed of
modular devices :
Voltage control relays dedicated
to protect air conditioning equip-
ments :
EU 100, EU 101 single phase
EU 301 three phase
Voltage control relay used to
survey DC or AC voltage :
EU 102 single phase product to
monitor DC or AC
EU 302 three phase control relay
used to check AC voltage
Current control relay used to
survey DC or AC current :
EU 103 single phase product to
monitor DC or AC current direct
via current transformer
Phase control relay
EU 300 to verify phase parame-
ters (asymmetry, loss of phase,
undervoltage)
The two digital control relays
EU 102 and EU 103 are
equipped with an LCD indicator.
During normal operation, the
LCD displays the measured
voltage (EU 102) or current
(EU 103). The LCD and the local
pushbuttons are also used to
enter the parameter settings
(type of signal, monitored lev-
els,...)
In case of an error, the relay willclose a contact (changeover
contact 8A)
For technical information
see page 429
Designation characteristics Width in I Pack Cat.
17.5mm qty. ref.
Single phase compressor Power supply 230V AC 2 1 EU100
control relay Under/over voltage control
Umin : 0,75 Un - Umax : 1,2 Un
Restart duration (5 or 10 minutes)
selected via bridge
Output : changeover contact
8A AC1 250V~
Single phase compressor Power supply 230V AC 2 1 EU101
control relay Under/over voltage control
Umin/Umax : +/-5% to +/-20% Un
set via potentiometer
Restart duration (5 or 10 minutes)
selected via switchOutput : changeover contact
8A AC1 250V~
Three phase compressor Power supply 400V AC 2 1 EU301
control relay Under/over voltage control
Umin/Umax : +/-5% to +/-20% Un
set via potentiometer
Restart duration (5 or 10 minutes)
selected via switch
Output : changeover contact
8A AC1 250V~
Phase control relay Power supply 400V AC 2 1 EU300
Under / over voltage control
Loss of phase, phase order control
Asymetry control : +/-5% to +/-20%
set via potentiometer
Output : changeover contact
8A AC1 250V~
EU100
EU301
8/10/2019 Modular Automation Ctrl Devices
40/82389
... Control relays
Designation characteristics Width in I Pack Cat.
17.5mm qty. ref.
Voltage control relay Power supply 230V~ 2 1 EU102
with LCD Voltage monitored DC 15 to 700V
or AC 15 to 480V~Under / over voltage or both
control bands
Parameter setting via pushbutton
and LCD indicator
Output : changeover contact
8A AC1 250V~
Three phase voltage Power supply Un 400V~ 2 1 EU302
control relay Under/over voltage control
Umin/Umax : +/-5% to +/-20% Un
set via potentiometer
Output : changeover contact
8A AC1 250V~
Current control relay Power supply Un 230V~ 2 1 EU103
single phase with LCD Current control DC or AC,
direct 0,1A to 10A or via current
transformer
Under / over current or
both control bands
Parameter setting via pushbutton
and LCD indicator
Output : changeover contact
8A AC1 250V~
EU102
Modular
devices
8/10/2019 Modular Automation Ctrl Devices
41/82390
Latching relays
Auxiliaries for latching relays
EP 050 EP 051 EP 052 EP 053
voltage rating (a) - (a)
24 to 230V AC
12to 110V DC - -
nominal load - 2A/250V AC - -
lmin/230V AC - 15mA - -working temperature -5 to +40C
storage temperature -40 to 80C
Connections : flexible 6
rigid 10
Latching relay connected Auxiliaries
with auxiliaries EP 050 EP 051 EP 052 EP 053
centralised control x
centralised control with remote
monitoring x x
centralised control with
multilevel central control x x
centralised control with remotesignalling and multilevel
centralised control x x x
remote signalling x
control by maintained contact x
control by maintained contact
with remote signalling x x
Technical characteristics
EP 510 EP 514 EP 501N EP 513 EP 511N EP 512 EP 525 EP 548 EP 528 EP 529
EP 515 EP 516 EP 503 EP 518 EP 519 EP 517 EP 540 EP 541
EP 520 EP 523 EP 526 EP 524 EP 521 EP 522 EP 546 EP 547
Coil in AC
voltage rating 230V 110V 48V 24V 12V 8V 230V 48V 24V 12V
tolerance +10/-20%
frequency 50/60Hz
start consumption 25VA 55VA
Coil in DC
voltage rating 110V 48V 24V 12V - 110V 24V 12V -
tolerance +10/-20%
start consumption 12w - 25w
Contacts
max. perm. Current AC1 16A
voltage 250V AC 400V AC
electrical endurance 150 000 operations
mechanical endurance 500 000 operationsohmic loss per current path 1.2W
minimum duration of impulse 50 ms
maximum time under voltage 1 H
pushbutton with signal lamp
without condensator 6 (1mA / lamp)
pushbutton with signal lamp with
condensator = 1uF parrallel * 10 (1mA / lamp)
pushbutton with signal lamp with
condensator = 2.2uF parrallel * 44 (1mA / lamp)
ingress protection IP20
working temperature -5 to +40C
storage temperature -40 to 80C
Connection
flexible 6
rigid 10
* condensator parrallel with the coil
(a) : function of the latchingrelay connected with anauxiliary
8/10/2019 Modular Automation Ctrl Devices
42/82391
Latching relays
Modular
devices
Technical characteristics
The following table shows the number of lamps which can be connected per phase at 230V 50Hz.
Incandescent lamps
230V lamps with and
without halogen
load : 40W 60W 75W 100W 150W 200W 300W 500W 1000W
number : 45 30 24 15 12 9 5 3 2
Low voltage halogen
load : 20W 50W 75W 100W 150W 300W
number : 70 28 19 14 9 3
Fluorescent lamps
uncompensated
load : 15W 18W 30W 36W 58W
number : 29 25 25 24 14
Parrallel compensation
load : 15W 18W 30W 36W 58W
number : 27 27 25 25 16
C total max
(a)
: 121F 121F 112F 112F 112F
Two lamp circuit,
series compensation
load : 2x18W 2x20W 2x36W 2x40W 2x58W 2x65W
number : 40 40 22 22 12 12
C : 2.7F 2.7F 3.4F 3.4F 5.3F 5.3F
load : 18W 36W 58W
number : 30 28 15
Two lamp circuit with electronics
power supply units
load : 2x18W 2x36W 2x58W
number : 15 13 8
Fluo compact uncompensated
load : 7W 10W 18W 26W
number : 50 45 40 25Fluo compact electronic power
supply unit
load : 11W 15W 20W 23W
number : 80 60 50 40
High intensity discharge
metal halogen lamps,
uncompensated
load : 50W 80W 125W 250W 400W
number : 11 9 7 3 2
Metal halogen lamps,
parrallel compensation
load : 50W 80W 125W 250W 400W
number : 9 8 6 3 2C total max(a) : 63F 58F 60F 54F 50F
High pressure sodium vapour
lamps, uncompensated
load : 70W 150W 250W 400W
number : 9 5 3 2
High pressure sodium vapour
lamps, parrallel compensated
load : 70W 150W 250W 400W
number : 5 3 2 1
C total max(a) : 60F 54F 64F 50F
(a) : these values must not be exceeded
8/10/2019 Modular Automation Ctrl Devices
43/82392
Latching relays
Installation of the auxiliaries
Application diagram
Auxiliaries for centralised control (EP 050 - EP 052)
Auxiliary contact (EP 051) Auxiliary for control by (EP 053)
4
2
3
1
3
11
14
12
11
14
12
A1
A2
1
2
3
4
A1
A2
1
2
3
4
N
31
32
34
11
14
12
11
14
12
A1
A2
1
2
3
4
A1
A2
1
2
3
4
ONOFF
33
31
32
34
33EPN 052
EPN 052
OFFON OFFON
EPN 050EPN 050 EPN 050EPN 050
21
23
22
24
A1
A2
1
2
3
4
11
12
14
A1
A2
1
2
3
4
generalcentralisedcommand
groupcentralisedcommand
groupcentralisedcommand
localcommand
localcommand
localcommand
localcommand
8/10/2019 Modular Automation Ctrl Devices
44/82393
Contactors and relays
Modular
devices
Consumption EN 145
control start and maintained
voltage consumption
12V DC 0.5W
24V DC 1.5W
12V AC 1VA
24V AC 2VA
Technical characteristics
Contactors Relays Interface relays
ES 110 ES 320 ES 240 ES 263 ES 224 ES 424 ES 252 ES 262 ER 120 ER 123 ER 124 EN 146 EN 145
ES 210 ES 420 ES 340 ES 365 ES 224A ES 424A ES 442 ES 462 ER 135 ER 138 ER 139 (a) (a)
ES 220 ES 430 ES 345 ES 463 ES 239 ES 242 ES 492
ES 230 ES 320A ES 440 ES 470
ES 237 ES 420A ES 480 ES 490
ES 110A ES 430A
ES 220A ES 450
ES 230A
Command
voltage(V) 230 230 230 230 24 24 24 24 230 24 12 230 10 to 26
Frequency % +10/-15 for all products
Hz 50/60Hz
Starting
consumption (VA) 15 20 50 50 15 20 50 50 15/20 15/20 15/20 5 (a)
Maintained
consumption (VA) 5 5 7 7 5 5 7 7 5 5 5 5 (a)
Max perm.
current AC1 (A) 25 25 40 63 25 25 40 63 16 16 16 5 5
Insulation
voltage (V) 250 400 400 400 250 250 400 400 250 250 250 250 250
Mech. endur. (%) 1 000 000 for all products
Working temp. (C) -10/+50 for all products
Storage temp. (C) -40/+80 for all products
Connection
control flexible 0.5 to 4 1 to 2.5 0.5 to 4 1 to 2.5 0.5 to 4
rigid 1 to 6 1.5 to 4 1 to 6 1.5 to 4 1 to 6
power flexible 1 to 6 1 to 6 1 to 6
rigid 1.5 to 10 4 to 25 1.5 to 10 4 to 25 1.5 to 10
Note : (a) electrical endurance : 200 000 operations at 5A AC1
Auxiliary contactsauxiliary contacts are available forthe range of relays and25A contactors.
Relays and 25A contactors with manual override1. permanent ON2. automatic3. permanent OFF
I
Auto
0
1
2
3
8/10/2019 Modular Automation Ctrl Devices
45/82394
Choice of contactors
Choice of contactors :
The choice of the contactor depends on the type of load(lighting etc.) and on the requirements(number of operations, working temperature).
Lighting :
A contactor can control a maximum number of lights as per the tablebelow.
Incandescent lamps230V lamps with and withouthalogen
40 W60 W75 W100 W150 W200 W300 W500 W1000 W
45302418129531
503528211410642
100756545332516105
1201059065453523147
low voltage halogen 20 W50 W75 W100 W150 W
702819149
8040262013
16080524026
240120786039
Fluorescent lamps
uncompensated 15 W18 W30 W36 W58 W
2925252414
5042353020
11080706040
1501301109060
parallel compensation15 W18 W30 W36 W58 W
Cmax.25 11225 11220 9020 9015 67
Cmax.30 13530 13525 11225 11217 76
Cmax.45 20245 20240 18040 18022 99
Cmax.60 27060 27055 24755 24740 180
two lamps circuits, series compensation 2 x 18 W 2,7 F2 x 20 W 2,7 F2 x 36 W 3,4 F2 x 40 W 3,4 F2 x 58 W 5,3 F2 x 65 W 5,3 F
404022221212
454526261313
909050502323
1401401001005050
electronics power supply units 18 W36 W58 W
302615
353017
603225
804530
two lamps circuits with electronics powersupply units
2 x 18 W2 x 36 W2 x 58 W
15138
17159
301612
402215
fluo compact uncompensated 7 W10 W18 W26 W
50454025
55504227
100906550
1301159080
fluo compact electronic powersupply unit
11 W15 W20 W23 W
80605040
85635242
1101007060
150130110100
High intensity discharge
metal halogen lamps, uncompensated 50 W80 W125 W250 W400 W
119731
1210832
362719107
5038261410
metal halogen lamps, parrallelcompensation 50 W
80 W125 W250 W400 W
Cmax.9 63 F7 49 F5 50 F3 54 F1 25 F
Cmax.10 70 F8 56 F6 60 F3 54 F2 50 F
Cmax.25 175 F21 147 F14 140 F7 126 F4 100 F
C max.30 210 F25 175 F17 170 F9 162 F6 150 F
70W150W250W400W
9531
10642
201064
3015106
high pressure sodium vapour lamps,parrallel compensated
70 W150 W
250 W400 W
Cmax.5 60 F
3 54 F1 32 F1 /
Cmax.6 72 F
3 54 F2 64 F1 50 F
Cmax.15 180 F
9 162 F5 160 F3 150 F
Cmax.20 240 F
16 198 F7 224 F5 250 F
Lamp type 16 A 25 A 40 A 63 A
high pressure sodium vapour lamps,uncompensated
8/10/2019 Modular Automation Ctrl Devices
46/82395
Choice of contactors
Modular
devices
Single phase with Three phase Choice of contactor according
capacitor (AC3 cat.) to control diagram
230V 400V 2 wires 3 wires
Maximum load 1.1 ES 220
in kW 2.2 ES 240
4 ES 320 - ES 420
7.5 ES 340 - ES 345 - ES 440
15 ES 365 - ES 463
Number of operations 50 000 100 000 150 000 200 000 300 000 single phase 230V three phase*400V
Maximum load* 4,4 4,4 3,9 3,5 2,9 ES 220 - ES 230
in kW 7,8 5,9 5 4,4 3,7 ES 240
12 8,8 7,7 6,6 5,9 ES 263
12 10,5 8,5 6,5 5,8 ES 320 - ES 430
23,2 17,7 15 13,1 10,8 ES 340
35 26,3 23 19,7 5,8 ES 463
Requirements of use influence of working temperature:
derating factor between 40C and 50C : 0.9example: heating with convectorthe maximum load of ES 220 is 4.4kW for 50 000 operationsand for a temperature
8/10/2019 Modular Automation Ctrl Devices
47/82396
Technical dataAnalogue time switches modular
Technical specifications
EH 010 EH 011 EH 110 EH 111 EH 171 EH 191
Width in I 17.5mm 1 1 3 3 3 5
Version daily daily daily daily weekly daily + weekly
Electrical characteristics
voltage supply 230V +10/-10%
frequency 50/60Hz
consumption 0.5VA
output 1NO 1 changeover
Switching capacity
AC1 16A/250V
inductive load (cos phi = 0.6) 4A/250V
incandescent lamps 900W
Characteristics
technology Quartz
dial 24 hours 7 days 24 hours and 7 days
min. switching 15 min 2 hours 15 min and 2 hours
max. number of switching 96 84 96/84
accuracy +/- 1 sec per day
supply failure reserve 200 hours 200 hours 200 hours 200 hoursreached in 120 hours 120 hours 120 hours 120 hours
manual override auto/ON/OFF
Environment
ingress protection IP20
working temperature -10 to +45C
storage temperature -10 to +50C
connection 0.5 to 4
PhN
3 4 5 621
M
EH 110 Electrical connections Simple time setting and programming using dual direction dial
Ph
N
EH010EH011
1 3
2 4
EH 010, EH 011
electrical connections
Programming by captive segments
8/10/2019 Modular Automation Ctrl Devices
48/82397
Technical dataAnalogue time switches 72 x 72 mm
Modular
devices
M
PhN
3 4 521
3 4 5
3 4 5
EH 710 Electrical connection
Very easy programmingwith dual direction dial
Manual override
53
Technical specifications
EH 710 EH 711 EH 770 EH 771 EH 712 EH 715 EH 716
Dimensions (mm) 72x72x48 72x72x48 72x72x48 72x72x48 72x72x48 72x72x48 72x72x48
Electrical characteristics daily daily weekly weekly daily daily daily
voltage supply 230V +10/-15% 110V to 240V AC 50/60Hz
50/60Hz 48V DC +10/-15%
consumption 0.5VA
output 1 changeover 1 N/O 1 changeover
Switching capacity
AC1 16A/250V
inductive load (cos phi = 0.6) 3A/250V
incandescent lighting 1000W
Characteristics
technology Quartz
dial 24h 7 days 24h
switching dial 10min 1 hour 10 min
minimum switching 20min 2 hour 20 min
working accuracy +/- 1 sec per day
supply failure reserve - 200 hours - 200 hours - 200 hours
reached in 120 hours 120 hours 120 hoursmanual switch temporary ON or OFF
Environment
working temperature -10 to +50C
storage temperature -20 to +60C
connection capacity 1 to 6
8/10/2019 Modular Automation Ctrl Devices
49/82398
Technical dataDigital time switches
Technical specifications
EG 010 EG 110 EG 210 EG 071 EG 170 EG 171 EG 172 EG 270 EG 470
Width in I 17.5mm 1 3 3 1 3 3 (pulsed) 3 3 5
Version daily daily daily weekly weekly weekly weekly weekly weekly
Electrical characteristics
voltage supply 230V +15/-15% 110/230V 230V +15/-15% 12V AC 110/230V 230V
50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz +15/-15%
+15/-15% 12V DC +15/-15% 50/60Hz
+15/-15%
consumption 1VA 20VA
output changeover contact
Switching capacity
AC1 16A/250V
inductive load (cos phi = 0.6) 3A/250V
incandescent lamps 1000W
Characteristics
accuracy +/- 1 sec per day
supply fai lure reserve Lithium battery total of three years
manual override permanent permanent ON/OFF permanent permanent ON/OFF
ON/OFF temporary ON/OFF ON/OFF temporary ON/OFFEnvironment
ingress protection IP20
working temperature -10 to +50C
storage temperature -10 to +50C
connection 0.5 to 4
Technical specifications
EG 103B/E EG 203B/E EG 400
Width in I 17.5mm 2 2 4
Version weekly weekly weekly / annualElectrical characteristics
voltage supply 230V+15% 230V+10%
-15% -15%
50/60Hz 50/60Hz
consumption max 6VA 0,5VA
output changeover contact changeover contact
Switching capacity
AC1 16A/250V 10A/250V
inductive load (cos phi = 0.6) 10A/250V
incandescent lamps 2300W
Characteristics
accuracy
supply failure reserve lithium battery : 5 years lithium battery : 10 yearsmanual override
Environment
ingress protection IP20
working temperature -5 to 45C -5 to +55C
storage temperature -20 to +70C -20 to +70C
connection
flexible 1 to 6 1 to 4
rigid 1.5 to 10 1.5 to 10
8/10/2019 Modular Automation Ctrl Devices
50/82399
Technical dataDigital time switches
Modular
devices
LN
65
21
43
EG 010
1 2 3
EG 170
3 4 5 621
LN
3 4 5 621
LN
EG 470
1 4 15
7 8 9
18 1 9
A
A
,B,C,D
C
11 12 13
B
10
D
1 6 1 7
OFF
20
OFF
P
- +
6
7
4
3
1
5
2
Electrical connections
EG 010
EG 170
EG 470
1 2 3 4 5 6 7
4
5
1
6 7 8 9
3
2
enter
reseton
off
progautomanu
OFF
Display :
1. Time2. Ouput contact (ON or OFF)3. Program selected
Buttons :4. To select the program to
apply5. To scroll program steps6. Reset7. + and - : change time
settings
Display :
1. Time2. Circuit status (ON or OFF)3. Day of the week (1=Monday,
2= Tuesday,...)
Buttons :
4. Mode selector : to selectone of the following modes :- time setting- programming- running mode- manual override
5. 1 to 7 : selection of thedays
6. ON/OFF : chooses whetherthe circuits is ON or OFF.
7. + and - : changessettings8. enter : to confirm selection9. reset
8/10/2019 Modular Automation Ctrl Devices
51/82400
Electronic time switches
You can return in Auto mode at any time with the menu key. If no actionis made during 1 min, the switch returns into Auto mode.
Reset :
- of programme : it can be completely delated by simultaneous push onthe 3 following keys : menu, ok and . the hour and the date are main-tained- Total : by simultaneous push on menu and ok keys and , the wholecontent of the product is removed. After a total reset, it is necessary toredefine the hour and the date.
Technical specifications
Electrical characteristics
- supply : 230 V AC 15 %- frequency : 50/60 Hz- consumption : max. 6 VA at 50 Hz
- output :1 changeover contact voltage free (EG 103B and EG 103E)2 changeover contacts voltage free (EG 203B and EG 203E)- max. breaking capacity :AC1 : 16A 250 VDC1 : 4A 12 V ...Cos = 0,6 : 10A 250 V
incandescent lamps :2300 Whalogen lamps : 230 V : 2300 Wcompensated fluorescent lamps // (max. 45F) : 400 Wnon compensated fluorescent lamps, compensated in series : 1000 Wfluo compact lamps : 500 W- min. breaking capacity :AC1 : 100 mA 250 VDC1 : 100 mA 12 V ...
- galvanic insulation between supply and output
Functional characteristics
- programming capacity : 56 steps shared on the 2 ways for EG 203Band EG 203E- min. time between 2 steps : 1 minute- accuracy : 1,5 sec / 24h- supply failure reserve : lithium battery total of 5 years of supply
failure- the product switches to watching state (display lighted of) after 1min without power. It returns into Auto mode at return of power or bypush on a button- ingress protection : IP 20
Environment
- working temperature : -5 to +45 C- storage temperature : -20 to +70 C
Connection by cage terminals
- flexible : 1 to 6
- rigid : 1,5 to 10
Main characteristics
- product delivered and updated to current date- automatic change of time schedule summer:winter- programming key :
for temporary overridefor the copy or the saving of the programme
- programming per day or group of days- 56 programmes steps ON, OFF
or impulse : 1 sec to 30 mn. (EG 103E and EG 203E)- permanent priority ON or OF ( fixes),- temporary overrides ON or OFF ( blinking),- holidays mode : priority setting ON or OFF between two dates
(EG 103E and EG 203E) ,- presence simultation (EG 103E and EG 203E)- barregraphe of visualization of the daily profile- possibility of locking the keyboard- programmable power off- backlighted screen (EG 103E and EG 203E),- remote controled temporary overrides (EG 103E).
menu : selection of the operatingmode
auto : functioning according to theestablished program
prog : new for the programmingprog : modif to modify an existing
program: checking of the program: modification of the hour, the dateand the choice of the mode ofchange of the time schedulesummer/winter
: holidays (EG 103E and EG 203E)+ and -:navigation or adjustment of the
values in Auto mode, selection of priority set-tings, overrides or of random functioning(EG 103E and EG 203E)
: to validate the blinking info: return at the preceding step
1
2
3
4
/
Product presentation
ok menu
+
autoprog
modifnew
OnOff
24181260
1
2
34/
/ -
1 3 5 7
2 4 6 8
EG 103B
/ +
N / -
1 3 5 7
2 4 6 8
EG 103E
/ +
N
1 3 5 7
2 4 6 8
EG 203E
A
B
Electrical connection
EG 103B EG 103E EG 203E / EG 203B
Ph Ph Ph
ok
temporaryoverride
N
8/10/2019 Modular Automation Ctrl Devices
52/82401
EG 400 programmer
Modular
devices
EG 400 programmer
Electrical characteristics
- supply : 230 V +10 -15% 50/60 Hz- consumption : 0,5 VA- output : 3 changeover switches and 1 normally open contact
10 A - 250 VAC1
Functional characteristics
- weekly and annual cycle- programming capacity : 102 program steps- precision of programming : 1 minute- functioning precision : 1 sec / day- supply failure reserve :
lithium battery total of 10 yearsdisplay disappears at power supply cut (hour, date, programremain memorized)
Environment
- working temperature : -5 at +55 C- storage temperature : -20 at +70 C
Connection capacity :
- flexible: 1 to 4
- rigid : 1,5 to 6
Presentation
A B C D
CIA
B
C
D3 521 74 6
auto
1X
p rg d ate prgPg1...Pg15
date
1
65
3
4
2
7
liquid crystal display screen
selection button for thevarious modes
Auto : automaticPrg : programmingDate : priority setting ON or
OFF programmabledate by date
: visualization: setting of hour and
date: modification of the
dates of timechanging for winterand summer
Pg1..Pg15 : programweeklyoverride
partial deletingaccording to mode :
- button for incrementing- button for assignment of
days and ways- button for choice of the
state of the instructionpriority setting of the waysscroll buttonsconnector for key EG 002
C D
A B
1 3 5 11 13
2 4 6 8 10 12 14 16
EG 400
7 9
Main characteristics
Change of time schedule summer/winter :
switch to the winter or summer times is pre-programmed for thelast Sunday of March and of September.Possibility to modify or inhibit these dates if necessary.Programming of 15 weekly cycles :
of different overrides from the basic cycle; these subprogrammescan be assigned to the various ways.Possibility of priority settings ON or OFF :
permanent :- by maintaining push on the button corresponding to the way- by programmation of date by datetemporary :- by brief push on the button corresponding to the wayFunctioning by impulse :
programmable for a maximum duration of 59sGrouping of days and ways :
setting