DATE: 27 May 2020DESIGNER: Kimberly BartlettPROJECT No: 70067793-WSP-XX-BR-CA-E-1301PROJECT NAME: Brill Place
Existing Lighting Installation. Lighting Calculation deemed to be inaccordance with the requirements of BS 5489-1:2013 & BS EN13201-2:2015 Class P2.
Required Levels: Achieved Levels:Eav = 10.0 to 15.00 Eav = 13.39Emin = 2.0 Emin = 2.69
MF: 0.84 x 0.93 = 0.78 0.84 x 0.86 = 0.72
Existing equipment: 6m & 8m columns complete with bracket armsand functional luminaires. Equipment optics assumed based on LBCamden online inventory.(opendata.camden.gov.uk/ Environment/Camden-Street-Lighting/dfq3-8wzu)
Outdoor Lighting Report
Designer: ................................................................................
Checked: ................................................................................
Approved: ...............................................................................
PREPARED BY: WSPUnit 9 The ChaseJohn Tate RoadFoxholes Business ParkHertfordSG13 7NN
\\uk.wspgroup.com\central data\projects\700677xx\70067793 - brill place\02 wip\li lighting\01 model\70067793-wsp-xx-br-ca-e-1301.rtma
DATE: 27 May 2020 DESIGNER:PROJECT No: 70067793-WSP-XX-BR-CA-E-1301PROJECT NAME:
Kimberly Bartlett Brill Place
7462328218
Layout ReportGeneral DataDimensions in Metres Angles in DegreesGrid Origin 529774.4m x 183043.7mArea 204.5m x 125.8mSample Spacing 1.49m x 1.50m
Luminaires
Luminaire X Data Supplier
Type
Lamp(s)
LampFlux(klm)/Colour
File Name
Maintenance Factor
Imax70,80,90(cd/klm)
No. in Project
Philips
2685 CNN-E#
1 MT 90 10450 2800 PGZ12
10.45 2800 / 70
Arc 2685 CNN E# 1 MT 90 10450 2800 PGZ12.ldt
0.78
447.0, 68.0, 1.0
6
Luminaire Y Data Supplier
Type
Lamp(s)
LampFlux(klm)/Colour
File Name
Maintenance Factor
Imax70,80,90(cd/klm)
No. in Project
Philips
2685 CNN-G#
1 MT 60 6800 2800 PGZ12
6.80 2800 / 70
Arc 2685 CNN G# 1 MT 60 6800 2800 PGZ12.ldt
0.72
509.0, 83.0, 1.0
2
Layout
ID Type X Y Height Angle Tilt Cant Out-
reach
Target
X
Target
Y
Target
Z
7 X 529818.29 183076.74 8.00 303.00 0.00 0.00 1.50
6 X 529835.51 183088.11 8.00 303.00 0.00 0.00 1.50
5 X 529849.25 183098.46 8.00 302.00 0.00 0.00 1.50
4 X 529869.62 183111.91 8.00 303.00 0.00 0.00 1.50
3 X 529892.38 183126.94 8.00 303.00 0.00 0.00 1.50
2 X 529917.63 183143.37 8.00 303.00 0.00 0.00 1.50
7 Y 529827.55 183106.14 6.00 32.00 0.00 0.00 0.50
8 Y 529821.27 183136.10 6.00 210.00 0.00 0.00 0.50
2
DATE: 27 May 2020 DESIGNER:PROJECT No: 70067793-WSP-XX-BR-CA-E-1301PROJECT NAME:
Kimberly Bartlett Brill Place
7462328218
Horizontal Illuminance (lux)Grid 1
6.56.46.39.49.79.39.08.7
12 1313 1312 12129.913 15 1717 1817 1715 13
8.91215 18 2022 2322 2017 145.67.310 1417 21 2427 2624 2016 13 9.4
4.96.38.411 1520 24 2728 2622 1814 11 8.14.14.75.67.09.413 1722 25 2624 2117 1411 8.66.64.8
4.44.85.56.57.91114 1821 23 2219 1512 9.27.36.04.83.75.25.35.55.96.67.69.11114 1718 18 1714 107.86.14.94.1
6.86.96.96.97.38.09.010 1113 1414 14 129.67.05.34.23.59.69.89.69.49.39.29.39.810 11 1111 1111 10 8.96.75.03.9
10 12 1314 1313 13 1312 1111 11 109.58.57.87.46.44.93.81114 16 1718 1818 17 1614 1211 10 9.38.06.85.85.24.5
7.410 1316 19 2122 2322 20 1714 119.68.67.66.55.34.43.86.48.511 1519 22 2527 2624 20 1613 9.97.96.96.05.04.1
4.95.77.29.613 1722 26 2828 2522 18 1411 8.46.45.34.53.85.15.76.58.11114 1924 26 2725 2117 14 119.17.05.14.13.42.9
5.75.86.16.77.79.31216 2023 24 2319 1512 9.67.76.55.24.13.32.77.67.67.57.78.29.311 1317 1920 19 1814 118.16.55.44.53.83.2
10 11 1110 1010 1011 12 1315 1616 15 1310 7.55.84.73.93.32.91314 15 1514 1414 1313 13 1313 1312 12 9.67.35.54.33.52.9
1214 1718 19 1919 1918 1614 13 1211 9.58.88.47.15.54.33.42.710 12 1517 2022 24 2525 2320 1714 12 108.87.56.45.85.14.23.4
1111 13 1720 2327 29 2928 2420 1613 9.98.26.95.84.94.23.73.21011 1213 15 1923 2730 31 2926 2218 1411 8.26.55.44.53.83.2
9.711 1212 1315 17 2126 2930 29 2622 1815 129.36.75.24.23.53.01012 13 1415 1517 20 2326 2827 24 2016 1311 9.27.35.54.23.41315 17 1818 1921 23 2424 2422 18 1512 9.78.16.85.64.41619 21 2223 2424 24 2321 1917 14 118.77.26.15.14.3
15 1922 25 2729 2826 23 2017 1513 9.98.06.55.44.69.51317 2126 29 3232 3025 20 1613 108.87.25.94.84.011 1419 2429 32 3330 2722 17 139.77.46.25.24.4
9.812 1621 2630 31 2925 2117 13 107.75.64.53.814 1822 2627 26 2319 1512 9.47.55.84.416 1921 2222 21 1714 118.56.75.44.3
1718 1817 16 1310.07.96.15.01414 1413 11 9.07.35.94.7
10 9.48.97.96.55.46.55.95.44.74.74.1
252525
25
2525
25
25
25
20
20
20
2020
20
2020
20
2020
1515
15
15
15
15
15
15
15
15
15
15
15
15
15
15
1010
10
10
10
10
10
10
10
1010
10
10
10
10
1010
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
SC
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
SIGN
BIN
BIN
BIN
BIN
PIPE
POST
POST
POST
POST
POST
POST
POST
POST
POST
POST
POST
POST
POST
POST
POSTPOST
POST
POST
POST
POST
POST
POST
POST
POSTPOSTPOST
IC
IC
IC
STUMP
STUMP
BUSH
DP
DP
G 0 .6 m
G 0 .6 m
G 0 .6 m
S 12 .0m
G 0 .9 m
S 12 .0m
G 0 .9 m
G 0 .9 m
G 0 .9 m
S 12 .0m
G 0 .9 m
G 0 .9 m
S 12 .0m G 0 .9 m
G 0 .9 m
G 0 .9 mG 0 .9 m
S 12 .0m
S 14 .0m
G 1 .3 m
G 1 .3 m
S 12 .0m
G 1 .3 m
G 1 .3 m
G 1 .3 m
G 1 .6 m
G 1 .6 m
S 10 .0m
S 16 .0m
S 20 .0m
S 14 .0m
G 1 .6 m
G 1 .9 m
G 1 .9 m
G 1 .9 m
G 1 .9 m
S 12 .0m
G 2 .2 m
MH
MH
MH
MH
MH MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
GU
GU
GU
GU
GU
GU
GU
GU
GU
GU
GU
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
FH
FH
IC
IC
IC
IC
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
SIGN
SIGN
SIGN
BOLBOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
WM
IC
IC
IC
IC
IC
IC
IC
CATV
CATVCATVCATV
CATV
CATV
CATV
WO
WOWO
WO
WO
GU
GU
GU
GU
TELTEL
TELTEL
TEL
TEL
TEL
TELTEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
DP
DP
G 0 .3 m
S 3.0 m
S 4.0 m
G 0 .3 m
G 0 .3 m
G 0 .3 m
G 0 .3 m
G 0 .6 m
G 0 .6 m
G 1 .3 m
G 1 .3 m
G 1 .6 m
BOL
S 4.0 m
S 4.0 m
S 3.0 m
S 4.0 m
S 3.0 m
G 0 .3 m
G 0 .3 m
S 4.0 m
S 14 .0m
S 12 .0m
G 1 .3 m
G 1 .6 mS 14 .0m
S 14 .0m
S 16 .0m
S 12 .0m
S 12 .0m
S 16 .0m
S 8.0 m
S 8.0 mG 0 .6 m
S 5.0 mS 20 .0m
S 6.0 m
S 6.0 m
G 0 .9 m
S 12 .0m
S 12 .0m
S 16 .0m
S 12 .0m
S 12 .0m
G 0 .9 m
G 0 .9 m
S 12 .0m
S 8.0 m
G 1 .3 m
S 12 .0mS 12 .0m
G 0 .9 m
G 0 .6 m
S 20 .0m
S 14 .0m
G 1 .6 m
G 1 .6 m
G 1 .6 m
S 14 .0m
S 15 .0m
G 1 .6 m
S 12 .0m
S 12 .0m
G 1 .9 m
S 12 .0m
S 12 .0m
S 2.0 m
MH
MHMH
GU
IC
SIGN
SIGN
SIGN
BOL
BOL
BOL
BOL
BOL
BOLBOL
BOL
BOL
BOL
BOLBOL
BOL
BOL
BOL
BOL
BOLBOL
BOL
IC
IC
IC
IC
IC
IC
IC
ICIC
IC
SV
GU
GU
GU
GU
GU
GU
GU
GU
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
Cycle Way
Sculpture
19.4m
7X
6X
5X
4X
3X
2X
7Y
8Y
183169.49m
183043.73m
529774.41m 529978.88m
Results Eav
Emin
Emax
Emin/Emax
Emin/Eav
13.39
2.69
32.59
0.08
0.20
3
DATE: 27 May 2020DESIGNER: Kimberly BartlettPROJECT No: 70067793-WSP-XX-BR-CA-E-1302PROJECT NAME: Brill Place
Proposed Lighting Design. Lighting Calculation in accordance withthe requirements of BS 5489-1:2013 & BS EN 13201-2:2015 ClassP2.
Required Levels: Achieved Levels:Eav = 10.0 to 15.00 Eav = 13.83Emin = 2.0 Emin = 2.77
MF: L0.90 x F0.1 x 0.92 = 0.83 0.84 x 0.86 = 0.72
Proposed equipment: 8m column in NAL temporary 750mm surfaceconcrete foundation complete with 1.25m bracket arm and ASDHighway Diamond MAXI 92LED 600mA M2 optic luminaire. Re-heading of existing column 3 withASD Highway Diamond MAXI92LED 600mA M2 optic luminaire.
Outdoor Lighting Report
Designer: ................................................................................
Checked: ................................................................................
Approved: ...............................................................................
PREPARED BY: WSPUnit 9 The ChaseJohn Tate RoadFoxholes Business ParkHertfordSG13 7NN
\\uk.wspgroup.com\central data\projects\700677xx\70067793 - brill place\02 wip\li lighting\01 model\70067793-wsp-xx-br-ca-e-1302.rtma
DATE: 27 May 2020 DESIGNER:PROJECT No: 70067793-WSP-XX-BR-CA-E-1302PROJECT NAME:
Kimberly Bartlett Brill Place
7462328218
Layout ReportGeneral DataDimensions in Metres Angles in DegreesGrid Origin 529774.4m x 183043.7mArea 204.5m x 125.8mSample Spacing 1.49m x 1.50m
Luminaires
Luminaire A Data Supplier
Type
Lamp(s)
LampFlux(klm)/Colour
File Name
Maintenance Factor
Lum. Int. Class
No. in Project
ASD Lighting
HWD6-#4LED09260-M2 Osram Rev 1
4000K Osram LED
16.72 4000/72
HWD6-#4K09260-M2 (167w).ldt
0.83
None
2
Luminaire X Data Supplier
Type
Lamp(s)
LampFlux(klm)/Colour
File Name
Maintenance Factor
Lum. Int. Class
No. in Project
Philips
2685 CNN-E#
1 MT 90 10450 2800 PGZ12
10.45 2800 / 70
Arc 2685 CNN E# 1 MT 90 10450 2800 PGZ12.ldt
0.78
G3
3
Luminaire Y Data Supplier
Type
Lamp(s)
LampFlux(klm)/Colour
File Name
Maintenance Factor
Lum. Int. Class
No. in Project
Philips
2685 CNN-G#
1 MT 60 6800 2800 PGZ12
6.80 2800 / 70
Arc 2685 CNN G# 1 MT 60 6800 2800 PGZ12.ldt
0.72
G3
2
Layout
ID Type X Y Height Angle Tilt Cant Out-
reach
Target
X
Target
Y
Target
Z
7 X 529818.29 183076.74 8.00 303.00 0.00 0.00 1.50
6 X 529835.51 183088.11 8.00 303.00 0.00 0.00 1.50
5 A 529854.45 183107.54 8.75 302.00 0.00 0.00 1.50
3 A 529892.38 183126.94 8.00 303.00 0.00 0.00 1.50
2 X 529917.63 183143.37 8.00 303.00 0.00 0.00 1.50
7 Y 529827.55 183106.14 6.00 32.00 0.00 0.00 0.50
8 Y 529821.27 183136.10 6.00 210.00 0.00 0.00 0.50
2
DATE: 27 May 2020 DESIGNER:PROJECT No: 70067793-WSP-XX-BR-CA-E-1302PROJECT NAME:
Kimberly Bartlett Brill Place
7462328218
Horizontal Illuminance (lux)Grid 1
1212 121516 1616 15
18 2022 2220 18161619 23 2729 2925 2117 16
14 1924 29 3335 3227 2218 169.81217 2229 34 3737 3227 2118 15 12
9.411 1418 2430 34 3533 2924 2017 14 128.19.110 12 1418 2326 30 3028 2420 1815 13 1213
9.510 1111 12 1417 1922 23 2322 1918 1715 14 12138.18.79.810 1111 12 1415 1618 19 1918 1817 1614 12
7.57.98.08.28.89.510 11 1214 1516 16 1616 1615 13117.67.27.17.07.17.37.88.79.49.91011 1212 12 1314 1412
9.18.27.56.96.76.56.56.87.28.08.79.19.49.59.910 12 1212 119.69.08.27.56.86.46.36.46.67.17.88.48.89.310 1213 13 12
1211 9.78.88.27.56.86.46.46.77.07.48.08.79.71113 1616 1416 1312 108.98.07.36.96.77.07.37.88.38.99.811 1316 18
2421 17 1412 118.77.87.37.37.88.28.69.09.49.811 12 141529 2622 18 1413 118.47.67.88.79.710 10 1010 1111 12 1212
30 3130 2621 17 1513 9.88.18.19.711 1312 11 1110 9.910.09.89.42730 2927 2420 16 1411 9.28.510 1314 1413 11 9.99.38.58.0
19 22 2526 2523 2017 15 1311 9.610.012 1414 1311 9.78.37.36.51517 19 2121 2119 1615 14 1311 1011 12 1211 108.67.26.0
1213 1315 16 1717 1616 1515 13 1211 9.89.89.78.87.76.55.24.612 11 1112 1414 15 1516 1514 1414 12 119.38.48.17.05.74.73.7
1211 11 1111 1213 13 1313 1314 1312 10 8.57.16.55.84.63.52.81111 1111 11 1111 1111 11 1212 1312 119.57.76.15.44.94.03.1
10 11 1212 1212 12 1211 1212 12 1212 1211 9.27.35.85.04.33.62.81112 13 1414 1413 13 1313 1415 16 1513 129.97.86.25.04.03.31315 16 1717 1717 17 1616 1719 18 1613 118.46.34.83.81618 20 2121 2221 20 1918 1919 17 1411 8.05.94.53.5
15 1821 24 2627 2624 22 2118 1716 14 117.55.24.09.71317 2125 28 3030 2825 21 1916 1412 9.77.04.83.511 1419 2428 31 3129 2623 19 1613 108.46.44.5
10.013 1621 2629 30 2825 2118 15 1310 7.55.54.114 1822 2527 26 2219 1513 11 8.97.05.216 1921 2222 20 1714 119.07.46.04.6
1718 1817 15 139.98.06.45.31514 1413 11 8.97.25.94.7
10 9.49.07.96.45.36.66.05.44.64.84.2
15
15
1515
15
15
15
15 1515
1515
15
15
1515
15
15
10
10
1010
10
1010
10
10
10
10
10
2.0
2.02.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
SC
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
SIGN
BIN
BIN
BIN
BIN
PIPE
POST
POST
POST
POST
POST
POST
POST
POST
POST
POST
POST
POST
POST
POST
POSTPOST
POST
POST
POST
POST
POST
POST
POST
POSTPOSTPOST
IC
IC
IC
STUMP
STUMP
BUSH
DP
DP
G 0 .6 m
G 0 .6 m
G 0 .6 m
S 12 .0m
G 0 .9 m
S 12 .0m
G 0 .9 m
G 0 .9 m
G 0 .9 m
S 12 .0m
G 0 .9 m
G 0 .9 m
S 12 .0m G 0 .9 m
G 0 .9 m
G 0 .9 mG 0 .9 m
S 12 .0m
S 14 .0m
G 1 .3 m
G 1 .3 m
S 12 .0m
G 1 .3 m
G 1 .3 m
G 1 .3 m
G 1 .6 m
G 1 .6 m
S 10 .0m
S 16 .0m
S 20 .0m
S 14 .0m
G 1 .6 m
G 1 .9 m
G 1 .9 m
G 1 .9 m
G 1 .9 m
S 12 .0m
G 2 .2 m
MH
MH
MH
MH
MH MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
GU
GU
GU
GU
GU
GU
GU
GU
GU
GU
GU
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
SC
FH
FH
IC
IC
IC
IC
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
SIGN
SIGN
SIGN
BOLBOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
WM
IC
IC
IC
IC
IC
IC
IC
CATV
CATVCATVCATV
CATV
CATV
CATV
WO
WOWO
WO
WO
GU
GU
GU
GU
TELTEL
TELTEL
TEL
TEL
TEL
TELTEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
DP
DP
G 0 .3 m
S 3.0 m
S 4.0 m
G 0 .3 m
G 0 .3 m
G 0 .3 m
G 0 .3 m
G 0 .6 m
G 0 .6 m
G 1 .3 m
G 1 .3 m
G 1 .6 m
BOL
S 4.0 m
S 4.0 m
S 3.0 m
S 4.0 m
S 3.0 m
G 0 .3 m
G 0 .3 m
S 4.0 m
S 14 .0m
S 12 .0m
G 1 .3 m
G 1 .6 mS 14 .0m
S 14 .0m
S 16 .0m
S 12 .0m
S 12 .0m
S 16 .0m
S 8.0 m
S 8.0 mG 0 .6 m
S 5.0 mS 20 .0m
S 6.0 m
S 6.0 m
G 0 .9 m
S 12 .0m
S 12 .0m
S 16 .0m
S 12 .0m
S 12 .0m
G 0 .9 m
G 0 .9 m
S 12 .0m
S 8.0 m
G 1 .3 m
S 12 .0mS 12 .0m
G 0 .9 m
G 0 .6 m
S 20 .0m
S 14 .0m
G 1 .6 m
G 1 .6 m
G 1 .6 m
S 14 .0m
S 15 .0m
G 1 .6 m
S 12 .0m
S 12 .0m
G 1 .9 m
S 12 .0m
S 12 .0m
S 2.0 m
MH
MHMH
GU
IC
SIGN
SIGN
SIGN
BOL
BOL
BOL
BOL
BOL
BOLBOL
BOL
BOL
BOL
BOLBOL
BOL
BOL
BOL
BOL
BOLBOL
BOL
IC
IC
IC
IC
IC
IC
IC
ICIC
IC
SV
GU
GU
GU
GU
GU
GU
GU
GU
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
Cycle Way
Sculpture
19.4m
7X
6X
5A
3A
2X
7Y
8Y
183169.49m
183043.73m
529774.41m 529978.88m
Results Eav
Emin
Emax
Emin/Emax
Emin/Eav
13.83
2.77
37.05
0.07
0.20
3
SC
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
LP
SIGN
BIN
BIN
BIN
BIN
PIPE
POST
POST
POST
POST
POST
POST
POST
POST
P
O
S
T
POST
POST
POST
POST
POST
POST
POST
POST
POST
POST
POST
POST
POST
POST
POST
POST
POST
POST
ELEC
IC
IC
IC
IC
STUMP
STUMP
STUMP
BUSH
DP
DP
G 0.3m
G 0.6m
G 0.6m
G 0.6m
S 12.0m
G 0.9m
G 0.9m
G 0.9m
G 0.9m
S 12.0m
G 0.9m
G 0.9m
G 0.9m
S 10.0m
G 0.9m
G 0.9m
S 12.0m
G 0.9m
G 0.9m
S 12.0m
G 0.9m
G 0.9m
G 0.9m
G 0.9m
S 12.0m
S 14.0m
S 14.0m
G 1.3m
G 1.3m
S 12.0m
G 1.3m
G 1.3m
G 1.3m
G 1.6m
G 1.6m
G 1.6m
G 1.6m
S 10.0m
S 16.0m
S 20.0m
S 14.0m
G 1.6m
G 1.9m
G 1.9m
G 1.9m
G 1.9m
S 12.0m
G 2.2m
MH
MH
MH
MH
MHMH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
GU
GU
GU
GU
GU
GU
GU
GU
GU
GU
SC
SC
SC
SC
SC
SC
SC
SC
FH
FH
IC
IC
IC
LP
LP
LP
LP
LP
LP
LP
LP
LP
SIGN
SIGN
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
WM
IC
IC
IC
IC
IC
IC
IC
CATV
CATV
CATV
CATV
CATV
CATV
WO
WO
WO
WO
WO
GU
GU
GU
GU
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
DP
DP
G 0.3m
S 3.0m
S 4.0m
G 0.3m
G 0.6m
G 1.6m
S 3.0m
G 0.3m
G 0.3m
S 4.0m
S 15.0m
S 15.0m
G 1.3m
S 14.0m
S 12.0m
G 1.3m
G 1.6m
S 14.0m
S 14.0m
S 16.0m
S 12.0m
S 12.0m
S 16.0m
S 8.0m
S 8.0m
G 0.6m
S 5.0m
S 20.0m
S 6.0m
S 6.0m
G 0.9m
S 12.0m
S 12.0m
S 16.0m
S 4.0m
S 15.0m
S 14.0m
S 14.0m
S 12.0m
G 1.3m
S 12.0m
G 0.9m
S 12.0m
S 12.0m
G 0.9m
S 10.0m
G 0.9m
S 12.0m
S 8.0m
G 1.3m
S 12.0m
S 12.0m
G 0.9m
G 0.6m
S 20.0m
S 14.0m
G 1.6m
G 1.6m
G 1.6m
S 14.0m
S 15.0m
G 1.6m
S 12.0m
S 12.0m
G 1.9m
S 2.0m
MH
MH
MH
GU
SIGN
SIGN
SIGN
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
BOL
IC
IC
IC
IC
IC
IC
IC
SV
GU
GU
GU
GU
GU
GU
GU
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
PFL
Sculpture
N
E
V
I
L
L
E
C
L
O
S
E
M
I
D
L
A
N
D
R
O
A
D
EC03
DNOX/T12
COLUMN
NC05
PRIV/T8
COLUMN
EC04
DNOD
COLUMN
EC05
DNOD
COLUMN
S3 - FOR REVIEW
wsp.com
WSP House, 70 Chancery Lane, London, WC2A 1AF, UK
T+ 44 (0) 207 314 5000, F+ 44 (0) 207 314 5111
DO NOT SCALE
APPROVED:
DRAWING No:
PROJECT No:
SCALE @ A3:
TITLE:
PROJECT:
DESIGNED:
CHECKED:
DATE:
REV:
ARCHITECT:
CLIENT:
DRAWING STATUS:
File
n
am
e \\U
K.W
SP
GR
OU
P.C
OM
\C
EN
TR
AL
D
AT
A\P
RO
JE
CT
S\7
00
67
7X
X\7
00
67
79
3 - B
RIL
L P
LA
CE
\0
2 W
IP
\L
I L
IG
HT
IN
G\0
2 D
RA
WIN
G\7
00
67
79
3-W
SP
-X
X-B
R-D
R-E
-1
30
1.D
WG
, p
rin
te
d o
n 2
9 M
ay 2
02
0 1
3:1
1:2
6, b
y B
artle
tt, K
im
be
rly
DRAWN:
WSP UK Ltd
c
70067793
70067793-WSP-XX-BR-DR-E-1301 P01
BRILL PLACE
LBS PROPERTIES LTD
1:500 PT PJB
KB May 20KB
TEMPORARY HIGHWAY LIGHTING WORKS
DURING BASEMENT WORKS PHASE
Reproduced from the Ordnance Survey map
with the permission of the Controller of Her
Majesty's Stationery Office. Licence no.
100048755. Crown copyright reserved.
RHINO BARRIERS FOR PIT LANE
2.4m SOLID HOARDING
TREE PROTECTION (FENCING)
EXISTING 8m COLUMN AND LUMINAIRE TO BE
REMOVED TO CONTRACTORS OFF SITE RECYCLING
FACILITY.
EXISTING COLUMN TO REMAIN. EXISTING
LUMINAIRE TO BE REMOVED TO CONTRACTORS OFF
SITE RECYCLING FACILITY AND REPLACED WITH
TYPE A LANTERN.
PROPOSED 8m TEMPORARY ROAD LIGHTING
COLUMN WITH TYPE A ASD HIGHWAY DIAMOND MIDI
LUMINAIRE COMPLETE WITH 7 PIN NEMA SOCKET.
OUTREACH BRACKET ARM: 1.25m
LAMP: 92LED 600mA 4000K 16.72klm
OPTIC SETTING: M2
CONTROL GEAR: INTEGRAL ELECTRONIC
ISOLATION: SECONDARY ISOLATOR FITTED WITH
BS88 FUSE
SWITCHING: LB CAMDEN SPECIFICATION
FOUNDATIONS: NAL 750mm TEMPORARY
CONCRETE FOUNDATION.
KEY:
EXISTING COLUMN TO REMAIN IN SITU.
ELECTRICAL SUPPLY ABBREVIATIONS.
NC - NEW COLUMN
EC - EXISTING COLUMN
DNO - DISTRIBUTION NETWORK OPERATOR
DNOD - PERMANENT DISCONNECTION
DNOX - NO DNO WORKS REQUIRED
PRIV - PRIVATE SUPPLY
NOTES:
1. CONTRACTOR TO LIAISE WITH DISTRIBUTION
NETWORK OPERATOR PRIOR TO
COMMENCEMENT OF WORKS.
2. CURRENT STATS DRAWING TO BE OBTAINED BY
CONTRACTOR PRIOR TO COMMENCEMENT OF
WORKS.
3. ALL EXISTING EQUIPMENT TO BE MADE
ELECTRICALLY SAFE PRIOR TO
COMMENCEMENT OF WORKS.
4. ALL ELECTRICAL WORKS TO BE CARRIED OUT IN
ACCORDANCE WITH BS7671 IET WIRING
REGULATIONS.
5. RE-USE OF EXISTING COLUMN 3 IS SUBJECT TO
SATISFACTORY STRUCTURAL TESTING
RESULTS. SHOULD THESE RESULTS NOT BE
SATISFACTORY, APPROVAL SHOULD BE
SOUGHT FROM LB CAMDEN FOR A REDUCTION
IN LIGHTING LEVELS THROUGH USE OF THE
EXISTING LUMINAIRE.
6. ELECTRICAL SUPPLY DESIGN TO BE
UNDERTAKEN BY OTHERS.
7. INSTALLATION AND MAINTENANCE DETAILS FOR
THE TEMPORARY CONCRETE BLOCK
FOUNDATION ARE TO BE SOUGHT FROM THE
MANUFACTURER PRIOR TO COMMENCEMENT
OF WORKS:
BEN PARSONS - NAL LTD
WEIR LANE, WORCESTER, WR2 4AY.
PHONE: 01905 427 100. FAX: 01905 427 030
EMAIL: [email protected]
- EQUIPMENT TYPE
- MAINTENANCE NUMBER
- CONNECTION TYPE, ACTION REQUIRED/
TERMINATION TYPE
PROPOSED EQUIPMENT ATTRIBUTE BOX:
COLUMN
NC00
DNOC/T12
INDICATES A RESIDUAL RISK REQUIRING A
COMPULSORY ACTION
INDICATES A RESIDUAL RISK FOR INFORMATION
INDICATES A RESIDUAL RISK REQUIRING A
PROHIBITIVE ACTION
INDICATES A RESIDUAL RISK AS A WARNING
HEALTH AND SAFETY SYMBOLS LEGEND
STATUTORY UNDERTAKERS PLANS NOT AVAILABLE AT
TIME OF DESIGN. CONTRACTOR TO ENSURE AVAILABILITY
OF CURRENT STATS PRIOR TO COMMENCEMENT OF
WORKS
PRIVATE CABLE NETWORK TO BE DESIGNED BY OTHERS.
ELECTRICAL DESIGN REQUIRES EARLY CONTRACTOR
INVOLVEMENT PRIOR TO COMMENCEMENT OF WORKS, TO
CONFIRM ORIGIN AND ROUTE OF ELECTRICAL SUPPLIES.
LANTERN & BRACKET LOCATION SCHEDULE
GENERAL BRACKET LANTERN LAMP
SWITCHING SUPPLY
CO-ORDINATES
MISCELLANEOUS
SCHEME
REF
MANUFACTURER
/REF
MATERIAL
MOUNTING
HEIGHT
COLUMN
SECTION /
TYPE
FOUNDATION DETAIL TYPE COLOUR PROJECTION INCLINATION MANUFACTURER
CATEGORY NO /
NAME
OPTIC SETTING CONTROL GEAR TILT TYPE
WATTAGE/
klm
EASTING NORTHING
EC03 EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING ASD
HIGHWAY
DIAMOND MIDI
M2
INTEGRAL
ELECTRONIC DALI
0°
92 LED
600mA
4000K CCT
167W
(16.72klm)
SWITCHED TO LB
CAMDEN
SPECIFICATION
DNOX/T12 EXISTING EXISTING
TO BE INSTALLED AS PER
CONTRACT DRAWINGS
NC05 TBC
TUBULAR
STEEL
8m
TUBULAR
STEEL
NAL TEMPORARY 750mm
CONCRETE BLOCK
FOUNDATION
SINGLE N/A 1.25m N/A ASD
HIGHWAY
DIAMOND MIDI
M2
INTEGRAL
ELECTRONIC DALI
0°
92 LED
600mA
4000K CCT
167W
(16.72klm)
SWITCHED TO LB
CAMDEN
SPECIFICATION
PRIV/T8 529854.416 183107.560
TO BE INSTALLED AS PER
CONTRACT DRAWINGS
S3 - FOR REVIEW
wsp.com
WSP House, 70 Chancery Lane, London, WC2A 1AF, UK
T+ 44 (0) 207 314 5000, F+ 44 (0) 207 314 5111
DO NOT SCALE
APPROVED:
DRAWING No:
PROJECT No:
SCALE @ A3:
TITLE:
PROJECT:
DESIGNED:
CHECKED:
DATE:
REV:
ARCHITECT:
CLIENT:
DRAWING STATUS:
File
n
am
e C
:\U
SE
RS
\U
KK
CB
00
2\O
NE
DR
IV
E - W
SP
O
36
5\B
RIL
L P
LA
CE
\7
00
67
79
3-W
SP
-X
X-B
R-D
R-E
-1
40
1.D
WG
, p
rin
te
d o
n 2
8 M
ay 2
02
0 1
3:0
5:1
3, b
y B
artle
tt, K
im
be
rly
DRAWN:
WSP UK Ltd
c
70067793
70067793-WSP-XX-BR-DR-E-1401 P01
BRILL PLACE
LBS PROPERTIES LTD
Custom PT PJB
KB May 20KB
TEMPORARY HIGHWAY LIGHTING WORKS
COLUMN SCHEDULE & TERMINATION DETAILS
DURING BASEMENT WORKS PHASE
Reproduced from the Ordnance Survey map
with the permission of the Controller of Her
Majesty's Stationery Office. Licence no.
100048755. Crown copyright reserved.
ELECTRICAL SUPPLY ABBREVIATIONS.
NC - NEW COLUMN
EC - EXISTING COLUMN
DNO - DISTRIBUTION NETWORK OPERATOR
DNOD - PERMANENT DISCONNECTION
DNOX - NO DNO WORKS REQUIRED
PRIV - PRIVATE SUPPLY
NOTES:
1. CONTRACTOR TO LIAISE WITH DISTRIBUTION NETWORK
OPERATOR PRIOR TO COMMENCEMENT OF WORKS.
2. ALL EXISTING EQUIPMENT TO BE MADE ELECTRICALLY
SAFE PRIOR TO COMMENCEMENT OF WORKS.
3. ALL ELECTRICAL WORKS TO BE CARRIED OUT IN
ACCORDANCE WITH BS7671 IET WIRING REGULATIONS.
4. ELECTRICAL SUPPLY DESIGN TO BE UNDERTAKEN BY
OTHERS.
5. INSTALLATION AND MAINTENANCE DETAILS FOR THE
TEMPORARY CONCRETE BLOCK FOUNDATION ARE TO BE
SOUGHT FROM THE MANUFACTURER PRIOR TO
COMMENCEMENT OF WORKS.
Project No 70067793 Project Name
Ref Risk Category*
& Phase where appropriate,
e.g. location/environment,
construction, operation, maintenance,
alteration/demolition
Work Element/Location
(where appropriate)
Hazard or Risk Issue Identified Risk Management
Owner
Design ERIc Action Required
(e.g. hazard elimination/risk mitigation action, information to
be provided to others)
Significant Temporary Works
Requirements/Management Arrangements and/or
any Special Erection/Installation Sequences or
Requirements
Design Action Status/Final Resolution Notes
(e.g. traceability of ERIc action, communication of
significant residual risk, critical design criteria, etc. )
Significant
Residual Risk§
Date Logged/
Reviewed
Raised By
001 Construction, maintenance,
demolition
Lantern installation Working at height - 'topping out' columns with
lanterns
Contractor removal of columns not possible, raise and lower columns
not appropriate for temporary installation. Standard
columns and MEWP access only reasonable solution for
scheme.
none Closed. Working at height for this type of work is
standard procedure for contractors working on street
lighting columns. Risk is mitigated through trained
and competent MEWP operators, clipping on, use of
lanyards and torqued helmets.
No 28/05/2020 K Bartlett
002 Location All Potential disruption/nuisance affecting the genetic
research facility, The Crick Institute on adjacent site
Lead Designer Reduce construction activities likely to disrupt operation of
facility, designing positions on the oppostie side othe road
only.
Initial design review carried out with design team.
Further regular design reviews planned to review
issues. No outstanding issues currently to be
addressed
No 28/05/2020 K Bartlett
003 Working adjacent to live traffic location works are on public highway, adjacent to live traffic
and construction vehicles at all times.
Contractor road closure ideal scenario however not possible due to
emergency routes, proximity to St Pancras International
station and live construction site.
Pit Lane in use and full site hoarding. Closed. Risk already mitigated in contractors design
and highway pit lane design by others.
No 28/05/2020 K Bartlett
004 Construction, maintenance,
demolition
Column installation risk of electrocution whilst connecting temporary
supply to temporary column.
Electrical Engineer Electrical design undertaken by others and managed by the
contractor. Reasonable risk mitigration provided on dwgs
stating design to be to BS7671 and liaison with DNO required
prior to commnecmenet of works.
Early contractor involvement required by electrical
designer to verify source of supply for temporary
lighting. Earthing electrodes may be required for
the temporary installation.
Closed. Notes provided on dwgs. No 28/05/2020 K Bartlett
005 Construction, maintenance,
demolition
Temporary foundation Risk of damage to foundation, crushing injuries during
install and removal
Contractor contractor to work with the foundation supplier and meet all
requiredment laid down by same. Note and contact details
for foundation manufacturer provided on 1301 dwg.
none Closed. Notes provided on dwgs. No 28/05/2020 K Bartlett
Issue 3.0Copy rows then insert above this line to ensure formula are copied
BMS: Project Delivery
T446: Design Risk Management Schedule Brill Place
Guidance Notes (see guidance notes page for more details)Design risk management should be an integral part of the overall design development and designers should think of it in terms of considering constructability, maintainability, etc. Designers only need to document their consideration of risks in this simple risk register format. There is no requirement for quantative design risk assessments to be carried out/documented and these should be avoided
* Risks should be considered in a logical sequence relating to the location/operational environment, constructability/installability, operability (normal/emergency), maintainability (inc routine cleaning, replacement, etc.), and alteration/decommissioning/dismantling/demolition, and should be categorised against those headings,
CIRIA guidance documents C755, C756, C686, C607 etc. provide a useful checklist and detailed guidance on the identification of risks to be considered during design and how those risks might be addressed - see detailed guidance notes for more details§ Significant residual risks are those which are unusual, not obvious, difficult to manage, or where critical design assumptions apply. The documentation by designers of residual risks that cover well-known and understood hazards should be avoided.
T446 Design Risk Management Schedule Page 1 of 1
2020-05-29T11:08:46+0100Bartlett, KimberlyDESIGNER
2020-05-29T14:20:57+0100Tearse, PeterChecker
2020-06-01T12:13:50+0100Batchelor, Paul (UKPJB004)Approved
2020-05-29T11:18:04+0100Bartlett, KimberlyDESIGNER
2020-05-29T14:19:48+0100Tearse, PeterChecker
2020-06-01T12:15:43+0100Batchelor, Paul (UKPJB004)Approved
2020-05-29T13:14:52+0100Bartlett, KimberlyDESIGNER
2020-05-29T14:23:55+0100Tearse, PeterChecker
2020-06-01T12:36:36+0100Batchelor, Paul (UKPJB004)Approved
2020-05-28T13:06:26+0100Bartlett, KimberlyDESIGNER
2020-05-29T14:24:37+0100Tearse, PeterChecker
2020-06-01T12:38:39+0100Batchelor, Paul (UKPJB004)Approved