Pega 367 with 04PC Control Layout Drawings ©Amada America, Inc.
Print Date 03/12/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 1 of 9
Pega 367 with 04PC Control Layout Drawings
Amada America Inc.7025 Firestone Blvd.
Buena Park CA. 90621Phone: (714) 739 2111
Fax: (714) 739 4099Email [email protected]
Pega 367 with 04PC Control Layout Drawings ©Amada America, Inc.
Print Date 03/12/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 2 of 9
Warning
! Qualified personnel must complete all work.
! Do not apply power to the Pega 367 until an A.E.S.I. (Amada Engineering andService Incorporated) Engineer is present and has instructed you to do so.
! Not all information required for proper installation, of the Pega 367 is included withthis document. Specific details for proper installation are found in the documentPega 367 with 04PC User Pre-installation Guide available at the Amada AmericaInternet web site at http://www.amada.com.
! Considerable effort has been made to ensure that this manual is free ofinaccuracies and omissions. However, as we are constantly improving ourproduct, some of the data contained herein may be out of date. Please check ourInternet site, http://www.amada.com, for the latest release of this document.
Pega 367 with 04PC Control Layout Drawings ©Amada America, Inc.
Print Date 03/12/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 3 of 9
Table Of Contents
Planning the Location of the Machine ..............................................................................................................................................4
Plan View - Pega 367.......................................................................................................................................................................5
Plan View - Pega 367 with V367hs Conveyor..................................................................................................................................6
Plan View - Pega 367 with V367hs Conveyor and MP1530 Loader ................................................................................................7
End View - Pega 367 .......................................................................................................................................................................8
Elevation View - Pega 367 ...............................................................................................................................................................9
Pega 367 with 04PC Control Layout Drawings ©Amada America, Inc.
Print Date 03/12/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 4 of 9
Planning the Location of the MachineThe following diagrams provide the details for positioning your new machine.
! Not all information required for proper installation, of the Pega 367 is included with this document. Specific details forproper installation are found in the document Pega 367 with 04PC User Pre-installation Guide available at the AmadaAmerica World Wide Web site at http://www.amada.com.
! No obstacles are allowed in the worksheet travel area and the ceiling must be at least 40" above the Pega 367.
! All of the Recommended Safety / Maintenance areas should be used, but you must at least ensure that the doors of the04PC control unit can be opened. Any reduction of the Recommended Safety / Maintenance areas may increase thepossibility of personnel injury and increase the time and cost of installation or maintenance.
! The Pega 367 and 04PC control must be protected from direct sunlight or other heat sources. Exposure to direct heatingsources such as infrared heaters have been shown to affect punch and die alignment.
Pega 367 with 04PC Control Layout Drawings ©Amada America, Inc.
Print Date 03/12/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 5 of 9
Plan View - Pega 367
60.0
0" w
orki
ng r
ange
368.00" Recommended Safety / Maintenance Area 40" from all components
Optional Material Support Tables Required
Optional Material Support Tables Required
120"
Max
imum
Tra
vel A
rea
60"
Mat
eria
l
288.00" Maximum Material Travel Area 144" Material
Electrical Requirements
Pega 367230 / 460 / 3 / 60 ±10% 18 kVA46 amps @ 230 / 3 / 60 VAC23 amps @ 460 / 3 / 60 VAC
Pega 367
Compressed Air Requirements
80 psi @ 8.8 ft/³min.
Operator Control Station
12" 12" 12"Scale
E1
E1
A1
A1
118.
03"
81.1
7"
199.
20"
Peg
a 36
7 Le
ngth
27.56"
49.2
1"
63.1
5"50
" min
. to
90" m
ax.
32.4
5"
74.25" 76.69"
150.94" Pega 367 Width
361.
98"
Rec
omm
ende
d S
afet
y / M
aint
enan
ce A
rea
40"
from
all
com
pone
nts
8"
04PCControl
Y-axis zero position
Center Track 200
Peg
a 36
7 C
ente
rline
Pega 367
Pega 367 with 04PC Control Layout Drawings ©Amada America, Inc.
Print Date 03/12/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 6 of 9
Plan View - Pega 367 with V367hs Conveyor
60.0
0" w
orki
ng r
ange
368.00" Recommended Safety / Maintenance Area 40" from all components
Optional Material Support Tables Required
Optional Material Support Tables Required
120"
Max
imum
Tra
vel A
rea
60"
Mat
eria
l
288.00" Maximum Material Travel Area 144" Material
Electrical Requirements
Pega 367230 / 460 / 3 / 60 ±10% 18 kVA46 amps @ 230 / 3 / 60 VAC23 amps @ 460 / 3 / 60 VAC
Pega 367
Compressed Air Requirements
80 psi @ 8.8 ft/³min.
P367hs Conveyor208 - 230 / 460 / 3 / 60 ±10% .8 kVA2.1 amps @ 208 / 3/ 60 VAC2.0 amps @ 230 / 3 / 60 VAC1.0 amps @ 460 / 3 / 60 VAC
Operator Control Station
12" 12" 12"Scale
E2
E2
E1
E1A1
A1
Access requiredthis area forslug removal
P36
7hs
118.
03"
81.1
7"
199.
20"
Peg
a 36
7 Le
ngth
420.
41"
Rec
omm
ende
d S
afet
y / M
aint
enan
ce A
rea
40"
from
all
com
pone
nts
27.56"
49.2
1"
63.1
5"50
" min
. to
90" m
ax.
32.4
5"
74.25" 76.69"
150.94" Pega 367 Width
44.85"
59.5
5"
04PCControl
Y-axis zero position
Center Track 200
Peg
a 36
7 C
ente
rline
Pega 367
8"
Pega 367 with 04PC Control Layout Drawings ©Amada America, Inc.
Print Date 03/12/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 7 of 9
Plan View - Pega 367 with V367hs Conveyor and MP1530 Loader
463.14" Recommended Safety / Maintenance Area 40" from all components
60.0
0" w
orki
ng r
ange
Optional Material Support Tables Required
Optional Material Support Tables Required
120"
Max
imum
Tra
vel A
rea
60"
Mat
eria
l
288.00" Maximum Material Travel Area 144" Material
MP1530Xformer
Forklift access required this area
MP1530
162.66" MP1530 Width
Electrical Requirements
Pega 367230 / 460 / 3 / 60 ±10% 18 kVA46 amps @ 230 / 3 / 60 VAC23 amps @ 460 / 3 / 60 VAC
Pega 367
Compressed Air Requirements
80 psi @ 8.8 ft/³min.
P367hs Conveyor208 - 230 / 460 / 3 / 60 ±10% .8 kVA2.1 amps @ 208 / 3/ 60 VAC2.0 amps @ 230 / 3 / 60 VAC1.0 amps @ 460 / 3 / 60 VAC
MP1530 Loader
29 amps @ 200 / 3 / 60 VAC
200 / 3 / 60 ±10%, 10 KvaTo operate at 230 / 460 VAC a step up transformer with the following service is required
26 amps @ 230 / 3 / 60 VAC13 amps @ 460 / 3 / 60 VAC
MP1530 Loader 75 psi @ 31.8 ft³/min.
Operator Control Station
12" 12" 12"Scale
E3
E2
E1
A1
A2
E1
A1
A2
E2
E3
Access requiredthis area for slug removal
P36
7hs
118.
03"
81.1
7"
199.
20"
Peg
a 36
7 Le
ngth
420.
41"
Rec
omm
ende
d S
afet
y / M
aint
enan
ce A
rea
40"
from
all
com
pone
nts
27.56"
49.2
1"
63.1
5"50
" min
. to
90" m
ax.
32.4
5"
74.25" 76.69"
150.94" Pega 367 Width
77.69" to edge of MP1530
44.85"
59.5
5"
223.
80"
MP
1530
leng
th
139.
00"
84.8
0"
8"
04PCControl
Y-axis zero position
Center Track 200
Peg
a 36
7 C
ente
rline
Pega 367
Pega 367 with 04PC Control Layout Drawings ©Amada America, Inc.
Print Date 03/12/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 8 of 9
End View - Pega 367
18.70"37.40"
43.31"
42.05"*Material
PassLine
93.50"*
131.10"*
12" 12" 12"Scale
Floor Line
*Dimension varies with installed options
76.69" 72.05"
Pega 367 with 04PC Control Layout Drawings ©Amada America, Inc.
Print Date 03/12/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 9 of 9
Elevation View - Pega 367
39.37" 36.61"9.84" 6.50"
11.02" 39.37"7.87"
199.21"112.59"
61.81"Throat Depth 60.00" Working Range
Track 200 Centerline
43.31"*Material Pass Line
27.56"
62.99"
94.76"*
*Dimension will change with installed options
Floor Line