+ All Categories
Transcript
Page 1: SPOC Automation at DUG Rockies "Reducing Lifting Costs"

Energy Savings usingVariable Frequency Drives (VFDs)on Beam Pumps

Page 2: SPOC Automation at DUG Rockies "Reducing Lifting Costs"

2

SPOC Automation Who Are We?

• Oil and Gas •Leader in Oilfield Variable

Speed Drives• Specialists in Optimizing Pump

Control with 200+ years of experience• 15+ Years in business• Family Owned• Based in Trussville, AL

Page 3: SPOC Automation at DUG Rockies "Reducing Lifting Costs"

3

Energy Savings using a VFD

• VFD has Power Factor up to .97, eliminating penalties

Page 4: SPOC Automation at DUG Rockies "Reducing Lifting Costs"

4

Energy Savings using a VFD

• Power Factor up to .97 eliminates penalties

• Can use NEMA B motors to save 3-5% additional energy

Page 5: SPOC Automation at DUG Rockies "Reducing Lifting Costs"

5

Energy Savings using a VFD

• Power Factor up to .97 eliminates penalties

• Can use NEMA B motors to save 3-5% additional energy

• VFDs eliminate regeneration

Page 6: SPOC Automation at DUG Rockies "Reducing Lifting Costs"

6

Energy Savings using a VFD

• VFD can eliminate regeneration

• When the heavier side of an unbalanced beam is moving up, the motor uses power

• When the heavier side of an unbalanced beam is moving down, the motor becomes a generator

• The generator sends power back into the electric grid• The utility does not give credit for this generated “negative” power

Page 7: SPOC Automation at DUG Rockies "Reducing Lifting Costs"

7

Eliminating wasted energy in regeneration

• Most Beam Pump VFDs use Dynamic Braking to deal with regeneration.

• Brake Resistors increase energy consumption 15-30%

• Iron Horse drives do not require resistors

Page 8: SPOC Automation at DUG Rockies "Reducing Lifting Costs"

Eliminating Wasted Energy in Regeneration

• The area in the green is typical lost as heat in a VFD with a brake resistor

• The area in the green is given back to the utility with a starter panel

Wasted Energy

Page 9: SPOC Automation at DUG Rockies "Reducing Lifting Costs"

Eliminating Wasted Energy in Regeneration

• Recent Well Test by Laredo Energy in Odessa, 7.1 SPM, 50HP motor

• With starter: 9.7KW of energy • With VFD: 7.3KW of energy

25% reduction in energy cost$4000 per year savings

Page 10: SPOC Automation at DUG Rockies "Reducing Lifting Costs"

Top Related