Whale Instant Match® Pumped ShowerDrainage System
Model Whale Instant Match® Kit
Flow Sensor Kit SDS223T
Mira Advance Extra 9.0 kW 1.1643.009
Mira Advance Flex Extra 9.0 kW 1.1643.010
Installation guidelines for
These kits may be used with the following Mira Advance showers:
To use the Instant Match with other Electric Showers an additional flowsensor is required. For installation and settings please see the separateinstructions enclosed
This booklet should be given to the customer after installation and demonstration
For i
llust
ratio
n pu
rpos
es o
nly
For i
llust
ratio
n pu
rpos
es o
nly
Typical Instant Match tray gulley installation Typical Instant Match wet floor gulley installation
Now with
2
This kit has been designed for the pumping of showerwaste water.
• When the shower is turned on the internal Mira flowsensor or external Venturi sensor signals thetransformer to supply dc voltage to the pump.
• Whilst showering, information about any variation offlow through the shower is sent to the Whale InstantMatch® transformer. This modifies the dc voltage tothe pump, maintaining optimum pump speed.
• When the shower is turned off the transformer stops the supply of dc voltage to the pump after apre-set delay.
• After a further 15 minutes the pump will switch onautomatically for a short time at a reduced pumpingspeed removing any water pooled in the showerarea.
• The pump has the ability to run dry without causingdamage to the pump.
• Before installation read the instructions.
• Plumbing installation must comply with the plumbingregulation as specified in the latest WRAS leaflet forplumbing systems.
• The electrical wiring must conform to BS7671: 2008Part 7 (17th Edition).
• Contact the Technical Helpline
(0845 0694 253) if you need further assistance.
The front cover illustrates the product in a typicalHealthcare installation.
Assess your installation prior to fitting so as to ensurethat the pump and transformer will be situated in anaccessible position.
Typical installations would have these components in anadjacent cupboard i.e. airing cupboard or in a false wallwith an access panel.
Incorrect installation may invalidate the warranty.
Principles of Operation
1.1 90mm Gulley 3
1.2 Venturi Sensor 3
1.3 Pump Mounting Instructions 3
1.4 Plumbing Layout 4
1.5 Pump Orientation 4
1.6 Rotation of Pump Head 4
1.7 Clamping Ring Fixing 4
1.8 Tray Gulley Installation 5
1.9 Wet Floor Gulley Installation 5
2.0 Plumbing 'Waste Fittings' 5
2.1 Macerator Connections 5
2.2 Transformer Mounting 6
2.3 Sensor Wire Connections 6
2.4 Transformer Settings 7
Illustrations Page
Principles of Operation 2
List of Parts included in the kit 3
Additional Parts 3
Plumbing Specification 4
Plumbing Gulley 5
Plumbing of Waste Pipe 5
Transformer Installation 6
Electrical Connections 6
Transformer Settings 6
Specification 7
Aftercare 7
EU Declaration of Conformity 7
Contents Page
3
Item Part No. Qty
Shower Drain Pump SDS021T 1
Pump Cover Base 755.178 1
Pump Cover 755.177 1
Transformer, Instant Match 755.449 1
Wet Floor Gulley 755.274 1
Tray Gulley Kit 755.108 1
Tricuspid Valve Holder 755.59 1
Tricuspid Valve 755.57 1
Rubber Waste Adaptor 2 part, 22 mm-11/2” fitting 1
22 mm-22 mm fitting 1
22 mm-15 mm fittings 2
Electrical connector block, two core 1
Cable ties 2
Fitting kit:
Female crimp spade connectors 2Mounting screws 8Washers 8
These parts are not supplied with the kit and may beordered from your distributor or stockist:
• 90 mm Gulley (O/A dimensions 64 mm h x 111 mm dia) Part No. AK1695 See Fig 1.1
• Flow Sensor Part Number SDS223T See Fig 1.2
Service Kit
• Diaphragm and Valves Service Kit Part No. AK1550
List of Parts included in kit Additional Parts
1.1
1.2
Use the backplate asa template to markthe position of themounting holes.
Use a 7mm bit to drillholes at markedpoints and insert No 8 wall plugs.
Use pliers to open up desired cable entrypoint on backplate.
Fix pump to wall using No 8 screws. Use crimpssupplied to terminate 24v cable from transformer,connect to pump and feed cable through entry point.Hold cable in place using adjacent cable bracket.
To fit cover, first locatebottom lug into backplateand pivot cover forward untiltop clips click into place.
To remove cover use two hands to push backplate clipstogether. As clips disengage, the cover will fall forwardand may be lifted away.
Note• The front cover may not fit properly if uneven
walls or tiling distorts the flexible back-plate.Loosen the pump fixing point causing thedistortion so that back-plate is flat and cover fits.Fill any gap between wall and back-plate withmastic or similar.
• If the pump is misaligned on the back-plate orpump head not parallel with back-plate thepush-fit connectors may prevent the front coverfrom fitting properly. Adjust pump, pump heador connecting pipework to achieve a good fit.
Pump Mounting Instructions Quick Guide1.3
• Rotate the pump head if necessary to connect thegulley to the pump by the most direct route. Loosenclamping ring screw, rotate and retighten as shown.See Fig 1.7 and 1.8
• Do not combine pump discharge with otherappliances as there is a risk of induced syphoning.Use an antisyphon trap where necessary.
• Before running water through the system ensure thatthe shower area and gulley are completely free ofbuilding debris, especially tile grout, screed materialand laytex.
4Plumbing Specification - Do Not Exceed This Specification
1.7
1.4
1.6
Horizontal to waste pipe - To increase pump life ensurethat 11/4” or 11/2” pipe is usedwith a gravity fall where thepipe length is greater than 1 m. If less than 1 m use 22 mm pipe.
With Instant Match systems do not use topsuction or side exit trays. Do not use insertsin plastic pipe.
Maximum pipe length for typical installation - extra elbows will reduce performance
Pipe from gulley to pump must be 15 mm. (Do not use 22 mm pipework. This will increase gulley noise).
Use only 22 mm pipe on pump outlet
Use only 15 mm pipefrom gulley to pump
Formed Bend
3m (max)3 m (max)
0.5 m (max)
1 m (max)lift on
discharge
0.2 m (min)0.4 m (max)
Formed Bend
• Whale pump is IP45 compliant and may be installedin zones 1, 2 or 3. Locate pump in accordance withBS7671: 2008 Part 7 (17th Edition).
• Max flow rate 8 ltrs/min in 15 mm inlet pipework.
• Use slow radius bends where possible.
• Ensure pipe edges are burr-free.
• Pipework must be secured. Inserts should not beused with plastic waste pipe. Do not use stemelbows. See page 3, Fig 1.3 pump mountinginstructions.
• Push home pipe into push-fit fittings and ‘Twist Lock’.
• Mount pump, head down, as shown.
• Mount the pump on a solid wall to prevent vibration.Use a back board if this is not possible. See Fig 1.6
• The shower floor must have a fall of at least 1 in 40 or 25 mm in 1m.
• Pump and transformer must be accessible after installation.
• Use one vertical lift to the pump and one vertical liftfrom the pump. See Fig 1.5
1.5
V33
1.5
5Plumbing Gulley
• The outlet of the pump may be connected into thewaste pipe, e.g. former bath waste. Black rubberfittings are provided for this.
• In confined bathrooms pump discharge may go intothe sink waste pipe using suitable adaptors. See Fig 2.1 for McAlpine examples.
Use with a Macerator Pump
• Discharge from the pump must go into the top of the macerator box, not into lower side entries.
Do not use the bottom entries. See Fig 2.2
• It is preferable to have two separate discharge linesto waste as any failure of the macerator will not bedetected by the Whale pump.
Plumbing of Waste Pipe
1.8
1.9
2.0
Top Tip: Leave the tray gulley hand tool in place or dustseal on wet floor gulley to keep out building debris, grout,etc. Only remove tool or seal after installation is finishedand shower area has been thoroughly cleaned.
2.1
C10
Orientate gulley so that it exits towards the pump inletto avoid unnecessary bends.
• When fitting in solid floors if copper pipe is used, itmust be sheathed to prevent corrosion.
Tray Gulley
• The tray gulley has a 35 mm profile to enable theshower drain to fit into a screed floor withoutpenetrating the damp-proof membrane. See Fig 1.9
• Use silicone on top of the seal to ensure propersealing beneath tray.
• Use the hand tool provided to tighten the lockingflange. See Fig 1.9
• Fit the gulley cover into the sockets and push downto secure. See Fig 1.9
Wetfloor Gulley
• The wet floor gulley has a 40 mm profile to enable itto fit into a screed floor without penetrating thedamp-proof membrane. See Fig 2.0
• Where a tray former is not used the gulley has twolugs either side of the discharge pipe to enable thegulley to be fixed to the floor whilst screed is laidaround the gulley.
• Where a tray former is used these lugs can bebroken off easily and the gulley mounted into the 160 mm gulley opening.
• The gulley has a conventional clamping ring toaccommodate vinyl flooring.
• The gulley cover clicks into place and may be easilyremoved for cleaning if required.
From pump
6Transformer Installation
Electrical Connections
Transformer Settings
• The transformer is IP45 compliant with the base platefitted and screwed to a flat surface.
• If mounted vertically wires must exit from the base ofthe transformer. See Fig 2.3
• Locate the transformer in accordance with BS7671: 2008 Part 7 (17th Edition). Transformer maybe installed in zone 2 or 3.
• Use only the brown and black sensor wires from thetransformer to connect to the two core sensor wire onthe Mira Advance Extra. The 3rd transformer sensor
wire (red wire) is not connected.
• The Mira signal wire connections to the transformersensor-wire are not polarity sensitive. Connection canbe made using the electrical connector block supplied.
10 Seconds: (Default Setting)
Suitable for most Electric Shower installations.
30 Seconds: Suitable for slow draining areas.
90 & 180 Seconds: Should not be used
Purge Cycle - After 15 minutes the transformer will reactivatethe pump for 30 seconds to remove any run-off orcondensation that has collected in the gulley to leave theshower area dry.
Test Button - The Test Button provides a quick andconvenient way to test the transformer and pump operation.Press, hold and release to energise pump. Green LED willilluminate on Test button.
• Mains supply to the transformer should be madeusing an unswitched, 5 amp fused spur.
• The transformer 24v RED and BLACK cable supply tothe pump should be terminated using the crimpconnectors supplied. Connect to the pump RED andBLACK male crimps. The polarity of the connectionmust be correct for the pump to operate.
2.2
2.3
Mark screw location Drill holes Insert plugs
Fix to WallTest Button
Mira Advance ExtraShower
Transformer
Transformer
Red
Brown
Mira Advance ExtraConnections to the Instant Match Transformer
For a largerimage seeenclosedQuick Guideif required
Red wire - Not for usewith MiraAdvance Extra
TransformerPu
mp
To M
ains
o
White
Brown
Black
The transformer is factory set for use with Mira Advance Extra.No adjustment should be necessary. The jumpers on the baseof the transformer may be moved to suit other makes ofelectric shower. See Fig 2.5 and enclosed Quick Guide.
Setting 1: Sensor type
Select the type of sensor used: Mira Advance Extra
(Default Setting) for Mira Shower internal sensor.
Gem Sensor (Do not use)
Venturi Sensor (see enclosed instructions if appropriate)
Setting 2: Off Delay (90 & 180 seconds: Should not be used) Adjust the time that the pump will over-run.
7
Pump
Model: SDS021TDry running current: 1.2 ampMaximum Head: 1.0 mMaximum Lift: 500 mmMaximum Head & Lift: 1.5 m
Whale’s policy is one of continuousimprovement and we reserve the right to change specifications withoutprior notice.
Transformer
Model: 755.44992 Watts intermittent ratingDouble insulatedThermal protectedMains cable 1.8 m (2 core, 0.5 mm2)Low voltage cables 5 m (10 amp rating)Pump control cable (3 core 5 m)Shower type selectorOff Delay of 10, 30, 90, 180 seconds5 amp Slow blow fuse
Specification
The Whale Instant Match® Transformer includes Active Linkdiagnostics to aid installation.
The green LED on the transformer will provide an illuminatedsignal as follows:
1 Having connected the transformer to the power sourcepress the Test Button, if power is present the green LEDwill illuminate.
Aftercare
The pump is maintenance free and does not normally require any attention. If the pumping performance reduces over time the following action may be taken:
• Clear inlet pipe of any debris or restriction caused by soap or other matter adhering to the internal bore by blowing, rodding or purging the pipe from the pump end toward the gulley.
• Replace the tricuspid valve if it has become inflexible or damaged using the service kit AK1550 or Tricuspid Valve (x10) Kit SDS 221T.
• Remove, rinse out and replace pump head.
• The diaphragm and internal valves do not normally require replacement.However, if they become damaged they may be replaced using the service kit AK1550.
Please see the enclosed insert for details of our warranty policy.
EU Declaration of Conformity
Description of Equipment: Shower Drain System
Manufacturer’s Declaration
We hereby declare, under our sole responsibility, that the above equipmentcomplies with the provisions of the following EC Directives.
Electromagnetic Compatibility Directive 2004/108/EC, on the approximation ofthe laws of the Member States relating to electromagnetic compatibility.
Low Voltage Directive 2006/95/EC on the harmonization of the laws of theMember States relating to electrical equipment designed for use within certainvoltage limits.
CE mark first affixed: 01/03/08
Basis on which conformity is declared
The above equipment complies with the protection requirements of the EMCDirective and the principal elements of the safety objectives of the Low VoltageDirective.
Standards applied
EN 60335-1:2001/A2:2006 Safety of household and similar electrical appliances
EN 60335-2-41:2003/A1:2004 Particular requirements for pumps
EN 55014-1:2000/A2:2002 Electromagnetic compatibility. Requirements forhousehold appliances, electric tools and similar apparatus. Emission
EN 55014-2:1997/A1:2001 Electromagnetic compatibility. Requirements forhousehold appliances, electric tools and similar apparatus. Immunity.
Signed
Stanley McFarlandEngineering Director
Whale 277-279 Old Belfast Road Bangor, Co. Down, BT19 1LTUK Technical Helpline: 0845 0694 253whalepumps.com [email protected]: +44 (0)28 9127 0531 fax: +44 (0)28 9146 6421
2.4
Off Delay(Seconds)
180
90
30
10
Mira A
dvance E
xtr
a
Gem
Sensor
Ventu
ri S
ensor
Not
Used
For a largerimage seeenclosedQuick Guideif required
2 Having connected the Instant Match transformer sensorcable to a Mira Advance Extra with Active Linkcompatibility the green LED will flash slowly to indicatecorrect connection.
3 When the shower is turned on and water passesthrough the flow sensor (internal shower/external) thegreen LED will flash rapidly to indicate correct operation.
©2011 Copyright Munster Simms Engineering Ltd (also trading as Whale)
all rights reserved. Whale® and Gulper® are registered trade names of
Munster Simms Engineering Ltd (also trading as Whale).
8Pum
p will not start
Pum
p will not stop
No f
urt
her
action
Check t
he M
ira
Advance E
xtr
a.
Call
Mira o
n:
0870 2
41 0
888.
Check s
ensor
wire is u
ndam
aged.
Sw
itch o
ff t
he p
um
pat
the m
ain
s a
nd
allo
w t
he
transfo
rmer
to c
ool
and r
eset.
If t
his
does n
ot
solv
e t
he
pro
ble
m r
epla
ce t
he
transfo
rmer
(755.4
49).
The t
ransfo
rmer
has a
n o
verr
un t
o a
llow
the
pum
p t
o c
ontinue t
o r
un a
fter
the s
how
er
has
been t
urn
ed o
ff.
The o
verr
un is f
acto
ry s
et
to 1
0seconds a
nd a
dju
sta
ble
to 3
0,
90 o
r 180 s
econds.
Does p
um
p c
ontinue t
o r
un e
ven a
fter
the s
et
over
run t
ime?
With t
he p
ow
er
supply
sw
itched o
n,
dis
connect
the s
ensor
wire b
etw
een t
he t
ransfo
rmer
& s
how
er. D
o n
ot
allo
w t
he t
wo d
isconnecte
dw
ires t
o t
ouch e
ach o
ther. T
his
will
sim
ula
te
the s
how
er, s
witchin
g o
ff.
Does p
um
p s
top a
fter
overr
un t
ime h
as p
assed?
Ensure
pow
er
is c
onnecte
d,
turn
ed o
n
and t
hat
the c
orr
ect
fuse h
as b
een f
itte
d.
Pre
ss a
nd r
ele
ase T
ES
T b
utton a
bove
transfo
rmer
cable
entr
y.
Does A
ctive-L
ink G
RE
EN
lig
ht
illum
inate
?
Check s
ignal cable
betw
een M
ira a
nd
transfo
rmer
is less
then 5
m long,
undam
aged a
nd t
hat
the c
onnection is g
ood
with R
ED
wire N
OT
connecte
d.
If
all
corr
ect
call
Mira o
n0870 2
410888.
Repla
ce t
ransfo
rmer
(755.4
49)
Repla
ce p
um
p(S
DS
021T
)
Does p
um
p s
tart
?
What is the fault?
Pum
p does not pum
p properly
Check flow rate
of shower
. T
he
pum
p is c
apable
of
8 l/m
in w
ith
Mira A
dvance
Extr
a S
how
er
on
15 m
m p
ipe.
Strong
suction is f
elt
Low
or Interm
ittent
suction is f
elt
Check suctio
n at pum
p inlet.
Low
/ n
osuction f
elt
Inlet pipe obstructed
,blocked
with deb
ris or
leaking air at joints.
- B
low
back o
r ro
d
inle
t pip
e f
rom
pum
p
to g
ulle
y a
nd c
heck
gulle
y a
rea f
or
debris.
Ensure
insert
s o
r ste
m(M
/F)
elb
ow
s a
re n
ot
used
and join
ts a
re a
irtight.
If p
roble
m p
ers
ists
,assem
ble
exte
rnal
pip
ew
ork
fro
m p
um
p t
ogulle
y. U
se t
op s
uction a
tgulle
y. T
urn
show
er
on.
Ifw
ate
r is
rem
oved p
roble
mm
ust
be in inle
t pip
ew
ork
.In
vestigate
furt
her.
Ensure fittings are
locked
and
airtig
ht.
Check t
he t
ricuspid
valv
e o
n p
um
pdis
charg
e is c
losed
and u
ndam
aged.
Spare
tricuspid
valv
es
in K
it N
o S
DS
221T
Ensure
outlet
pip
ew
ork
is n
ot
blo
cked.
Rem
edy a
ny
pro
ble
ms.
Str
ong
suction f
elt
Rem
ove b
lue c
lam
pin
g r
ing t
o r
ele
ase p
um
p h
ead.
C
heck v
alv
es f
or
debris a
nd t
hat
they s
eat
pro
perly.
Rin
se h
ead a
nd r
epla
ce.
Ensure
dia
phra
gm
is in low
est
positio
n a
nd b
ead f
its into
gro
ove o
n p
um
p b
ody
and p
um
p h
ead.
Do n
ot
pin
ch it.
Rubber
part
s a
reconta
ined in t
he S
erv
ice K
it (
AK
1550)
No f
urt
her
action
Ensure
that
no h
air o
r debris b
locks t
he g
ulle
y.
Pre
ss t
he TEST
button o
n t
he t
ransfo
rmer
to s
tart
the p
um
p.
Assess t
he s
uction a
t th
e g
ulle
y.
Whale In
stant Match
®Mira Fault Diagno
sis Chart
Does t
his
solv
e t
he
pro
ble
m?
No
No
No
Yes
Yes
Yes
No
Yes
No
Yes
No
Yes
No
Yes
Yes
Yes
No
No
Technical Helpline: 0845 0694 253 Ref No: 182.79_v4_0111
Check t
ransfo
rmer
connections
at
pum
p a
re c
orr
ect; R
ed t
oR
ed,
Bla
ck t
o B
lack.
If c
orr
ect
rem
ake c
onnections w
ith a
connecto
r blo
ck.
Pre
ss a
nd
rele
ase t
est
button.
Does p
um
pS
tart
?
Connect
transfo
rmer
usin
g a
plu
gto
a k
now
ngood s
ocket;
sw
itch o
n;
pre
ss T
ES
Tbutton.
Does
GR
EE
N lig
ht
illum
inate
?
Measure
voltage a
t tr
ansfo
rmer
dc c
onnection w
hen T
ES
Tbutton is p
ressed.
Is 1
0 -
20
volts d
c p
resent?
Turn
show
er
on.
Does p
um
p s
tart
?
No f
urt
her
action
Gems Flow Sensor Connections to the Instant Match Transformer
Transformer
Transformer
Transformer
Transformer
Internal Shower Gems Flow Sensor Connections to the Instant Match Transformer
Gems Flow Sensor
Internal Shower
Gems Flow Sensor
Transformer
Venturi Flow Sensor
Red
Red
Brown
Red
Red
Red
Black
Black
Black
Brown
Black
BlueGreen
Brown
White Green
Brown
Brown
Venturi Flow Sensor Connections to the Instant Match
Transformer
Mira Advance
Extra ShowerTransformer
Transformer
Brown
Red
Black
Brown
White
Mira Advance Extra Connections to the Instant Match Transformer
Red wire �
Not for use
with Mira
Advance Extra
Transformer
Earthing of IM Transformer
The pump running when no water is flowing through the
Venturi sensor indicates an earthing issue.
To resolve this add a supplementary earth lead from the
spur connected to the Instant Match transformer to the
nearest earth point, e.g. water pipe.
Pu
mp
To
Ma
ins
Transformer
Transformer
Transformer
Transformer
Pu
mp
Pu
mp
Pu
mp
To
Ma
ins
To
Ma
ins
To
Ma
ins
Flow Sensor Connections to the
Instant Match Transformer
oo
oo
These settings are only designed as a guide - adjust settings to suit the specific installation.
Setting 1: Sensor TypeSelect the type of sensor used.• Mira Advance Extra WIRED (Default Setting - Foruse with sensor wire. See overleaf for sensor connec-tions).• Venturi Sensor (For use with a Venturi sensor - PartNo. SDP223T. See overleaf for sensor connections andwhen required read instructions enclosed with VenturiSensor).• Gems Sensor (For use with Gems Sensor and TritonSafeguard Digilink. See overleaf for sensor connection /connections to Triton Safeguard Digilink).
Setting 2: Off Delay (10, 30 seconds)Adjust the time that the pump will over-run to clear theshower tray/area to suit the installation.10 Seconds: (Default Setting) Suitable for most ElectricShower installations.
30 Seconds: Suitable for slow draining areas.
Purge Cycle - After 15 minutes the transformerwill reactivate the pump for 30 seconds to removeany run-off or condensation that has collected inthe gulley to leave the shower area dry.Test Button - The Test Button provides a quick and convenient way to test thetransformer and pump operation.Press, hold and release to energise pump.
The Whale Instantmatch Transformer includesActive Link diagnostics to aid installation.The greenLED on the transformer will provide an illuminatedsignal as follows:1. Having connected the transformer to the powersource press the Test Button, if power is presentthe green LED will illuminate.2. Having connected the Instantmatch transformer sensor cable to a Mira Advanced Extra with ActiveLink compatibility the green LED will flash slowly toindicate correct connection.3. When the shower is turned on and water passesthrough the flow sensor (internal shower/external)the green LED will flash rapidly to indicate correctoperation.
(755.499 replacement for transformers - 755.299, 755.349, 755.399 and 755.449)To make adjustments move the jumpers on the base of the transformer to connect pairs of contacts to suit the particular installation asfollows:
Quick Guide for Instant Match Transformer for Connection to the Mira Advance Extra, Venturi Flow Sensor, Gems Flow Sensor and Internal Shower Gems Flow Sensor
Part No. 180.145_v2_0111 interim
Whale’s policy is one of continuous improvement and we reserve the right to change specifications without prior notice.
Technical Helpline 0845 0694 253
Unused
Whale, 277-279 Old Belfast Road, Bangor Co Down, N Ireland whalepumps.com [email protected]
Unused
STATEMENT OF LIMITED WARRANTY
The products manufactured and supplied by the Company (“Products”), are warranted to be free from material defects in
design, workmanship and material under normal use (“Defects”) for (unless otherwise extended in advance in writing by
the Company) a period of 3 years from date of purchase, save that this warranty shall not apply where the Defect is
attributable to defective materials supplied by third parties. In such event, the only remedy of the buyer of the Products
(“Buyer”) will be against that third party.
This warranty applies only to Products that are properly installed and used in accordance with all oral and written
maintenance and operation instructions provided by the Company. The Company shall not be liable for a breach of any of
the warranties in this Statement of Limited Warranty if the Buyer makes any further use of the Products after giving the
Company notice of any Defect or the Buyer alters or repairs such Products without the written consent of the Company.
Products that have been disassembled or modified (without prior written approval of the Company), are not covered by
this warranty.
All Products are covered by a 3 year limited warranty (detailed below) from (unless otherwise extended in advance in
writing by the Company) date of purchase (“Standard Warranty”). In addition to the Standard Warranty, these Products
will be covered by a further warranty of 2 years but only when the registration form is completed and returned
(“Additional Warranty”). The period of such Additional Warranty shall commence automatically the date the Standard
Warranty expires.
In the event that any of the warranties offered by the Company are breached, the Company shall (at its discretion) repair,
replace or issue a spares kit for the defective Product subject to prior examination at Company premises. If the Company
complies with this paragraph, it shall have no further liability for a breach of the warranties in respect of such Products.
Adjustment or replacement of defective parts made under this warranty will not extend the warranty period applicable
either under the Standard Warranty and/or the Additional Warranty.
The Company shall not bear any costs of removal, installation, transportation, or other charges that may arise in
connection with a warranty claim by the Buyer. Such costs shall be the Buyer’s sole responsibility.
No claim in respect of defective Products will be valid unless the alleged defective Products are returned at the Buyer’s
expense to the Company for inspection, together with proof of purchase.
Non-stock/ special order items are non-returnable by the Buyer in any circumstances, and this warranty does not apply to
prototype models.
EXCLUSIONS:
The Company shall not be liable for any indirect loss or for any special, incidental, punitive or consequential damages
suffered by the Buyer and/or any third party, whether this loss arises from breach of a duty in contract or tort or breach of
a statutory duty or in any other way, including, without limitation, loss arising from the negligence, default, breach of duty,
non-delivery, delay in delivery or defects or errors in the work undertaken by the Company pursuant to the terms of this
Statement of Limited Warranty or in connection with any other claim arising in connection with manufacture and/or supply
of the Products.
In particular, the Company shall not be liable (without limitation) for:
• Loss of profits, increased production costs or other economic injury or loss;
• Loss of contracts or opportunity; and/or
• (insofar as is permitted by applicable law) damage to property of the Buyer or any third party.
The Company shall under no circumstances be liable for any breach of its obligations hereunder and/or under any
contract governing sale and purchase of the Products (“Contract”) resulting from causes beyond its control including but
not limited to fires, strikes, lockouts, insurrection or riots, terrorism or civil disorder, embargoes, wrecks or delays in
transportation, requirements or regulations of any governmental authority, tempest, earthquake or other natural disaster,
flood, bursting or overflowing of water tanks, failure or shortage of power, fuel or other utilities, or loss of data and/or
communications due to causes such as those referred to in this paragraph.
Munster Simms Engineering Limited and Whale Water Systems Inc
(a subsidiary of Munster Simms Engineering Limited) (“Company”)
This statement sets out the Company's entire liability in respect of the Products and the Company's liability under this
statement shall be in lieu of all other warranties, conditions, terms and liabilities, express or implied, statutory or
otherwise howsoever except any implied by law which cannot be excluded.
All warranties, conditions and other terms implied by statute or common law (save for the conditions implied by section
12 of the Sale of Goods Act 1979) are, to the fullest extent permitted by law, excluded from the Contract.
Subject to the remaining provisions of this Statement of Limited Warranty, the Company’s total liability in contract, tort
(including negligence or breach of statutory duty), misrepresentation, restitution or otherwise, arising in connection with
the performance or contemplated performance of the Contract and supply of the Products shall be limited to the
Contract price.
Nothing in this Statement of Limited Warranty shall operate so as to exclude or restrict the Company’s liability for death
or personal injury caused by its negligence.
The Company shall NOT be liable for any condition, warranty or representation made by a distributor or other person
acting on behalf of the Company unless expressly confirmed by the Company in writing.
This Statement of Limited Warranty shall be governed and construed in accordance with Northern Irish law and all
disputes arising in connection hereto shall be submitted to the exclusive jurisdiction of the Northern Irish Courts.
DISCLAIMERAll Products are rated and appropriate for use with water unless otherwise specified by the Company. Compatibility and suitability for
other liquids should be verified in writing by the Company prior to such use. All specification information on Products included in
Product literature is based on tests using clean cold water unless otherwise specified. Any performance / specification figures shown
have been calculated using standard testing procedures. Where maximum output is stated, such maximum output refers to pumps
acting at zero lift and zero head. Actual performance may vary depending on the application, installation and environmental factors.
Neither the accuracy nor completeness of the information contained in any Product brochure is guaranteed by the Company and may
be subject to change at its sole discretion. The Company may, at its sole discretion, change the technical performance, dimensions or
appearance of any of its Products without prior notification to purchasers. The Company shall not be liable to a purchaser for any
indirect or consequential loss or damage (whether for loss of profit, loss of business, depletion of goodwill or otherwise), costs,
expenses or other claims for consequential compensation whatsoever (howsoever caused) which arise out of or in connection with
the use of a Product. Where dimensions are stated, such dimensions are for guidance only. Inch measurements are conversions from
millimetre dimensions and are shown to the nearest 1/16". US gallons volumes are conversions from litres and are also shown for
guidance purposes only to the nearest 1/16. Please contact the Company directly if precise measurements are required.
Ref: 181.148_v1_0309_QCF223_v3