Quality... Strength.... Durability...
and
MAINTENANCE FREE!
The Complete Product Line ofPresents
A (Plants Nationwide)1-888-965-3227
(Plants Nationwide) 1-888-965-3227
5
(Plants Nationwide) 1-888-965-3227
5
INDEX
Benefits of StarTrack . . . . . . . . . . . . . . . . . . . . . 4
StarTrack II x 5’-0”. . . . . . . . . . . . . . . . . . . . . . . . . . . 5, 6
StarTrack II-HD . . . . . . . . . . . . . . . . . . . . . . . . 7, 8
StarTrack II x 7’-6” . . . . . . . . . . . . . . . . . . . . 9, 10
StarTrack II x 17’-6” . . . . . . . . . . . . . . . . . . 11,12
Star Track Inspection Pit . . . . . . . . . . . . . . 13,14
Startrack Base Options. . . . . . . . . . . . . .15,16
Industry, Intermodal . . . . . . . . . . . . . . . . . . .17
Curved Crossings,Heavy Loads. . .18
Improved Rail Groove Inserts. . . . . . .19
Suggested Installation . . . . . . . . . . 20
Benefits of StarTrack............................... 4
StarTrack II x 5’-0”................................... 5
StarTrack II-HD........................................7
StarTrack II x 7’-6”................................... 9
StarTrack II x17’-6”..................................11
StarTrack Inspection Pit.................... ......13
StarTrack Base Options.................... ......15
Industry, Intermodal.................................17
Curved Crossings, Heavy Loads.............18
Improved Rail Groove Inserts..................19
Suggested Installation............................. 20
Insert Assemblies.................................... 21
Rubber Inserts Installation.......................22
Joint Gap Filler Strip Installation..............24
(Plants Nationwide) 1-888-965-3227
5
A (Plants Nationwide)1-888-965-3227
(Plants Nationwide) 1-888-965-3227
5
(Plants Nationwide) 1-888-965-3227
5
(Plants Nationwide) 1-888-965-3227
5
(Plants Nationwide) 1-888-965-3227
5
A (Plants Nationwide)1-888-965-3227
MATERIALS: CONCRETE: THE MINIMUM 28 DAY STRENGTH SHALL BE 6000 PSI. Optional: Special design mix utilizing Micro-Silica. Optional: Corrosion inhibitor additive in lieu of epoxy reinforcing.
REBAR: ASTM A615, GRADE 60. Optional: Epoxy-coated
SHOULDERS: “PANDROL” #6575 CAST SHOULDER DUCTILE - IRON GRADE #65-45-12
RUNNING STRIPS: 3/16” UHMW POLYETHYLENE
CLIPS: “PANDROL” #E2055 CLIPS - SPRING STEEL
INSULATORS: “PANDROL” #7400 THERMOPLASTIC / NYLON
EXPOSED SURFACE: FORM CAST CONCRETE. Optional: Hydrozo “Enviroseal” Surface Treatment
DESIGN LOADING: COOPER E-80 WITH 60% IMPACT
(Plants Nationwide) 1-888-965-3227
5
(Plants Nationwide) 1-888-965-3227
5
(Plants Nationwide) 1-888-965-3227
5
(Plants Nationwide) 1-888-965-3227
5
(Plants Nationwide) 1-888-965-3227
5
A (Plants Nationwide)1-888-965-3227
(Plants Nationwide) 1-888-965-3227
5
4” PVC PERF. WRAPPED W/ FILTER FABRIC TO DRAINAGE STRUCTURE
FILTER FABRIC
3/8” MINUS FINE AGGREGATE
(Plants Nationwide) 1-888-965-3227
5
A (Plants Nationwide)1-888-965-3227
MATERIALS: CONCRETE: THE MINIMUM 28 DAY STRENGTH SHALL BE 6000 PSI. Optional: Special design mix utilizing Micro-Silica. Optional: Corrosion inhibitor additive in lieu of epoxy reinforcing.
REBAR: ASTM A615, GRADE 60. Optional: Epoxy-coated
SHOULDERS: “PANDROL” #6575 CAST SHOULDER DUCTILE - IRON GRADE #65-45-12
RUNNING STRIPS: 3/16” UHMW POLYETHYLENE
CLIPS: “PANDROL” #E2055 CLIPS - SPRING STEEL
INSULATORS: “PANDROL” #7400 THERMOPLASTIC / NYLON
EXPOSED SURFACE: FORM CAST CONCRETE. Optional: Hydrozo “Enviroseal” Surface Treatment
DESIGN LOADING: COOPER E-80 WITH 60% IMPACT
(Plants Nationwide) 1-888-965-3227
5
(Plants Nationwide) 1-888-965-3227
5
(Plants Nationwide) 1-888-965-3227
57
NON-SKID3/16" DIAMOND
PLATE PATTERNRAIL BLOCK-OUT HEIGHT
EQUALS RAIL HEIGHT GROUT PLUGS(3 TYPICAL)
1:40 RAIL CANTTO CENTER
3/16" UHMWPOLYETHYLENE
NYLON INSULATORTYPE P10
“PANDROL” BRAND RAILCLIP TYPE “E 2055’
RAIL DETAIL
MATERIALS:CONCRETE: THE MINIMUM 28 DAY STRENGTH SHALL
BE 6000 PSI. Optional: Special design mix utilizing Micro-Silica.Optional: W. R. Grace’s “D.C.I.” additive
in lieu of epoxy reinforcing
REBAR: ASTM A615 GRADE 60.Optional: Epoxy-coated
SHOULDERS: “PANDROL” #5274 CAST SHOULDERDUCTILE - IRON GRADE #65-45-12
RUNNING STRIPS: 3/16" UHMW POLYETHYLENE
CLIPS: “PANDROL” #E2055 CLIPS - SPRING STEEL
INSULATORS: “PANDROL” #4263THERMOPLASTIC / NYLON
EXPOSED SURFACE: FORM CAST CONCRETE.Optional: Hydrozo “Enviroseal” #40 Surface Treatment
DESIGN LOADING:COOPER E-80 WITH 60% IMPACT
“PANDROL”RAG STEM
SHOULDER
T M
STARTRACK II - HDWEIGHT = 10,400 lbs.
(Plants Nationwide)1-800-316-1660
5’-- 0”
2’-- 5 1/4”
2’-- 5 1/4”
1’-- 1 1/2”
1’-- 1 1/2”
11’-- 0”
3’-- 10 1/2”1’-- 4”
4/96
7
NON-SKID3/16" DIAMOND
PLATE PATTERNRAIL BLOCK-OUT HEIGHT
EQUALS RAIL HEIGHT GROUT PLUGS(3 TYPICAL)
1:40 RAIL CANTTO CENTER
3/16" UHMWPOLYETHYLENE
NYLON INSULATORTYPE P10
“PANDROL” BRAND RAILCLIP TYPE “E 2055’
RAIL DETAIL
MATERIALS:CONCRETE: THE MINIMUM 28 DAY STRENGTH SHALL
BE 6000 PSI. Optional: Special design mix utilizing Micro-Silica.Optional: W. R. Grace’s “D.C.I.” additive
in lieu of epoxy reinforcing
REBAR: ASTM A615 GRADE 60.Optional: Epoxy-coated
SHOULDERS: “PANDROL” #5274 CAST SHOULDERDUCTILE - IRON GRADE #65-45-12
RUNNING STRIPS: 3/16" UHMW POLYETHYLENE
CLIPS: “PANDROL” #E2055 CLIPS - SPRING STEEL
INSULATORS: “PANDROL” #4263THERMOPLASTIC / NYLON
EXPOSED SURFACE: FORM CAST CONCRETE.Optional: Hydrozo “Enviroseal” #40 Surface Treatment
DESIGN LOADING:COOPER E-80 WITH 60% IMPACT
“PANDROL”RAG STEM
SHOULDER
T M
STARTRACK II - HDWEIGHT = 10,400 lbs.
(Plants Nationwide)1-800-316-1660
5’-- 0”
2’-- 5 1/4”
2’-- 5 1/4”
1’-- 1 1/2”
1’-- 1 1/2”
11’-- 0”
3’-- 10 1/2”1’-- 4”
4/96
7
NON-SKID3/16" DIAMOND
PLATE PATTERNRAIL BLOCK-OUT HEIGHT
EQUALS RAIL HEIGHT GROUT PLUGS(3 TYPICAL)
1:40 RAIL CANTTO CENTER
3/16" UHMWPOLYETHYLENE
NYLON INSULATORTYPE P10
“PANDROL” BRAND RAILCLIP TYPE “E 2055’
RAIL DETAIL
MATERIALS:CONCRETE: THE MINIMUM 28 DAY STRENGTH SHALL
BE 6000 PSI. Optional: Special design mix utilizing Micro-Silica.Optional: W. R. Grace’s “D.C.I.” additive
in lieu of epoxy reinforcing
REBAR: ASTM A615 GRADE 60.Optional: Epoxy-coated
SHOULDERS: “PANDROL” #5274 CAST SHOULDERDUCTILE - IRON GRADE #65-45-12
RUNNING STRIPS: 3/16" UHMW POLYETHYLENE
CLIPS: “PANDROL” #E2055 CLIPS - SPRING STEEL
INSULATORS: “PANDROL” #4263THERMOPLASTIC / NYLON
EXPOSED SURFACE: FORM CAST CONCRETE.Optional: Hydrozo “Enviroseal” #40 Surface Treatment
DESIGN LOADING:COOPER E-80 WITH 60% IMPACT
“PANDROL”RAG STEM
SHOULDER
T M
STARTRACK II - HDWEIGHT = 10,400 lbs.
(Plants Nationwide)1-800-316-1660
5’-- 0”
2’-- 5 1/4”
2’-- 5 1/4”
1’-- 1 1/2”
1’-- 1 1/2”
11’-- 0”
3’-- 10 1/2”1’-- 4”
4/96
7
NON-SKID3/16" DIAMOND
PLATE PATTERNRAIL BLOCK-OUT HEIGHT
EQUALS RAIL HEIGHT GROUT PLUGS(3 TYPICAL)
1:40 RAIL CANTTO CENTER
3/16" UHMWPOLYETHYLENE
NYLON INSULATORTYPE P10
“PANDROL” BRAND RAILCLIP TYPE “E 2055’
RAIL DETAIL
MATERIALS:CONCRETE: THE MINIMUM 28 DAY STRENGTH SHALL
BE 6000 PSI. Optional: Special design mix utilizing Micro-Silica.Optional: W. R. Grace’s “D.C.I.” additive
in lieu of epoxy reinforcing
REBAR: ASTM A615 GRADE 60.Optional: Epoxy-coated
SHOULDERS: “PANDROL” #5274 CAST SHOULDERDUCTILE - IRON GRADE #65-45-12
RUNNING STRIPS: 3/16" UHMW POLYETHYLENE
CLIPS: “PANDROL” #E2055 CLIPS - SPRING STEEL
INSULATORS: “PANDROL” #4263THERMOPLASTIC / NYLON
EXPOSED SURFACE: FORM CAST CONCRETE.Optional: Hydrozo “Enviroseal” #40 Surface Treatment
DESIGN LOADING:COOPER E-80 WITH 60% IMPACT
“PANDROL”RAG STEM
SHOULDER
T M
STARTRACK II - HDWEIGHT = 10,400 lbs.
(Plants Nationwide)1-800-316-1660
5’-- 0”
2’-- 5 1/4”
2’-- 5 1/4”
1’-- 1 1/2”
1’-- 1 1/2”
11’-- 0”
3’-- 10 1/2”1’-- 4”
4/96
A (Plants Nationwide)1-888-965-3227
(Plants Nationwide) 1-888-965-3227
5
4” PVC PERF. WRAPPED W/ FILTER FABRIC TO DRAINAGE STRUCTURE
FILTER FABRIC
3/8” MINUS FINE AGGREGATE
(Plants Nationwide) 1-888-965-3227
5
A (Plants Nationwide)1-888-965-3227
(Plants Nationwide) 1-888-965-3227
5
(Plants Nationwide) 1-888-965-3227
5
(Plants Nationwide) 1-888-965-3227
5
MATERIALS: CONCRETE: THE MINIMUM 28 DAY STRENGTH SHALL BE 6000 PSI. Optional: Special design mix utilizing Micro-Silica. Optional: Corrosion inhibitor additive in lieu of epoxy reinforcing.
REBAR: ASTM A615, GRADE 60. Optional: Epoxy-coated
SHOULDERS: “PANDROL” #6575 CAST SHOULDER DUCTILE - IRON GRADE #65-45-12
RUNNING STRIPS: 3/16” UHMW POLYETHYLENE
CLIPS: “PANDROL” #E2055 CLIPS - SPRING STEEL
INSULATORS: “PANDROL” #7400 THERMOPLASTIC / NYLON
EXPOSED SURFACE: FORM CAST CONCRETE. Optional: Hydrozo “Enviroseal” Surface Treatment
DESIGN LOADING: COOPER E-80 WITH 60% IMPACT
NON-SKID3/16" DIAMOND
PLATE PATTERN
RAIL BLOCK-OUT HEIGHTEQUALS RAIL HEIGHT
GROUT PLUGS(3 TYPICAL)
1:40 RAIL CANTTO CENTER
3/16" UHMWPOLYETHYLENE
NYLON INSULATORTYPE P10
“PANDROL” BRAND RAILCLIP TYPE “E 2055’
RAIL DETAIL
MATERIALS:CONCRETE: THE MINIMUM 28 DAY STRENGTH SHALL
BE 6000 PSI. Optional: Special design mix utilizing Micro-Silica.Optional: W. R. Grace’s “D.C.I.” additive
in lieu of epoxy reinforcing
REBAR: ASTM A615 GRADE 60.Optional: Epoxy-coated
SHOULDERS: “PANDROL” #5274 CAST SHOULDERDUCTILE - IRON GRADE #65-45-12
RUNNING STRIPS: 3/16" UHMW POLYETHYLENE
CLIPS: “PANDROL” #E2055 CLIPS - SPRING STEEL
INSULATORS: “PANDROL” #4263THERMOPLASTIC / NYLON
EXPOSED SURFACE: FORM CAST CONCRETE.Optional: Hydrozo “Enviroseal” #40 Surface Treatment
DESIGN LOADING:COOPER E-80 WITH 60% IMPACT
“PANDROL”RAG STEM
SHOULDER
T M
STARTRACK II x 7'6"WEIGHT = 9,550 lbs.
(Plants Nationwide) 1-800-316-1660
8’-0”
3’-10 1/2”
1’-1 1/2”
11 1/4”
7’ -6”
1’ -2” 11 1/4”
1’-1 1/2”
(5’0” versionalso available)
9
NON-SKID3/16" DIAMOND
PLATE PATTERN
RAIL BLOCK-OUT HEIGHTEQUALS RAIL HEIGHT
GROUT PLUGS(3 TYPICAL)
1:40 RAIL CANTTO CENTER
3/16" UHMWPOLYETHYLENE
NYLON INSULATORTYPE P10
“PANDROL” BRAND RAILCLIP TYPE “E 2055’
RAIL DETAIL
MATERIALS:CONCRETE: THE MINIMUM 28 DAY STRENGTH SHALL
BE 6000 PSI. Optional: Special design mix utilizing Micro-Silica.Optional: W. R. Grace’s “D.C.I.” additive
in lieu of epoxy reinforcing
REBAR: ASTM A615 GRADE 60.Optional: Epoxy-coated
SHOULDERS: “PANDROL” #5274 CAST SHOULDERDUCTILE - IRON GRADE #65-45-12
RUNNING STRIPS: 3/16" UHMW POLYETHYLENE
CLIPS: “PANDROL” #E2055 CLIPS - SPRING STEEL
INSULATORS: “PANDROL” #4263THERMOPLASTIC / NYLON
EXPOSED SURFACE: FORM CAST CONCRETE.Optional: Hydrozo “Enviroseal” #40 Surface Treatment
DESIGN LOADING:COOPER E-80 WITH 60% IMPACT
“PANDROL”RAG STEM
SHOULDER
T M
STARTRACK II x 7'6"WEIGHT = 9,550 lbs.
(Plants Nationwide) 1-800-316-1660
8’-0”
3’-10 1/2”
1’-1 1/2”
11 1/4”
7’ -6”
1’ -2” 11 1/4”
1’-1 1/2”
(5’0” versionalso available)
9
NON-SKID3/16" DIAMOND
PLATE PATTERN
RAIL BLOCK-OUT HEIGHTEQUALS RAIL HEIGHT
GROUT PLUGS(3 TYPICAL)
1:40 RAIL CANTTO CENTER
3/16" UHMWPOLYETHYLENE
NYLON INSULATORTYPE P10
“PANDROL” BRAND RAILCLIP TYPE “E 2055’
RAIL DETAIL
MATERIALS:CONCRETE: THE MINIMUM 28 DAY STRENGTH SHALL
BE 6000 PSI. Optional: Special design mix utilizing Micro-Silica.Optional: W. R. Grace’s “D.C.I.” additive
in lieu of epoxy reinforcing
REBAR: ASTM A615 GRADE 60.Optional: Epoxy-coated
SHOULDERS: “PANDROL” #5274 CAST SHOULDERDUCTILE - IRON GRADE #65-45-12
RUNNING STRIPS: 3/16" UHMW POLYETHYLENE
CLIPS: “PANDROL” #E2055 CLIPS - SPRING STEEL
INSULATORS: “PANDROL” #4263THERMOPLASTIC / NYLON
EXPOSED SURFACE: FORM CAST CONCRETE.Optional: Hydrozo “Enviroseal” #40 Surface Treatment
DESIGN LOADING:COOPER E-80 WITH 60% IMPACT
“PANDROL”RAG STEM
SHOULDER
T M
STARTRACK II x 7'6"WEIGHT = 9,550 lbs.
(Plants Nationwide) 1-800-316-1660
8’-0”
3’-10 1/2”
1’-1 1/2”
11 1/4”
7’ -6”
1’ -2” 11 1/4”
1’-1 1/2”
(5’0” versionalso available)
9
NON-SKID3/16" DIAMOND
PLATE PATTERN
RAIL BLOCK-OUT HEIGHTEQUALS RAIL HEIGHT
GROUT PLUGS(3 TYPICAL)
1:40 RAIL CANTTO CENTER
3/16" UHMWPOLYETHYLENE
NYLON INSULATORTYPE P10
“PANDROL” BRAND RAILCLIP TYPE “E 2055’
RAIL DETAIL
MATERIALS:CONCRETE: THE MINIMUM 28 DAY STRENGTH SHALL
BE 6000 PSI. Optional: Special design mix utilizing Micro-Silica.Optional: W. R. Grace’s “D.C.I.” additive
in lieu of epoxy reinforcing
REBAR: ASTM A615 GRADE 60.Optional: Epoxy-coated
SHOULDERS: “PANDROL” #5274 CAST SHOULDERDUCTILE - IRON GRADE #65-45-12
RUNNING STRIPS: 3/16" UHMW POLYETHYLENE
CLIPS: “PANDROL” #E2055 CLIPS - SPRING STEEL
INSULATORS: “PANDROL” #4263THERMOPLASTIC / NYLON
EXPOSED SURFACE: FORM CAST CONCRETE.Optional: Hydrozo “Enviroseal” #40 Surface Treatment
DESIGN LOADING:COOPER E-80 WITH 60% IMPACT
“PANDROL”RAG STEM
SHOULDER
T M
STARTRACK II x 7'6"WEIGHT = 9,550 lbs.
(Plants Nationwide) 1-800-316-1660
8’-0”
3’-10 1/2”
1’-1 1/2”
11 1/4”
7’ -6”
1’ -2” 11 1/4”
1’-1 1/2”
(5’0” versionalso available)
9
A (Plants Nationwide)1-888-965-3227
(Plants Nationwide) 1-888-965-3227
5
4” PVC PERF. WRAPPED W/ FILTER FABRIC TO DRAINAGE STRUCTURE
FILTER FABRIC
3/8” MINUS FINE AGGREGATE
(Plants Nationwide) 1-888-965-3227
5
A (Plants Nationwide)1-888-965-3227
(Plants Nationwide) 1-888-965-3227
5
(Plants Nationwide) 1-888-965-3227
5
(Plants Nationwide) 1-888-965-3227
5
MATERIALS: CONCRETE: THE MINIMUM 28 DAY STRENGTH SHALL BE 6000 PSI. Optional: Special design mix utilizing Micro-Silica. Optional: Corrosion inhibitor additive in lieu of epoxy reinforcing.
REBAR: ASTM A615, GRADE 60. Optional: Epoxy-coated
SHOULDERS: “PANDROL” #6575 CAST SHOULDER DUCTILE - IRON GRADE #65-45-12
RUNNING STRIPS: 3/16” UHMW POLYETHYLENE
CLIPS: “PANDROL” #E2055 CLIPS - SPRING STEEL
INSULATORS: “PANDROL” #7400 THERMOPLASTIC / NYLON
EXPOSED SURFACE: FORM CAST CONCRETE. Optional: Hydrozo “Enviroseal” Surface Treatment
DESIGN LOADING: COOPER E-80 WITH 60% IMPACT
RAIL BLOCK-OUTHEIGHT EQUALS
RAIL HEIGHT
GROUT PLUGS(5 TYPICAL)
3/16" UHMWPOLYETHYLENE
NYLON INSULATORTYPE P10
“PANDROL” BRAND RAILCLIP TYPE “E 2055’
RAIL DETAIL
MATERIALS:CONCRETE: THE MINIMUM 28 DAY STRENGTH SHALL
BE 6000 PSI. Optional: Special design mix utilizing Micro-Silica.Optional: W. R. Grace’s “D.C.I.” additive
in lieu of epoxy reinforcing
REBAR: ASTM A615 GRADE 60 AND POST-TENSIONING TENDONS
Optional: Epoxy-coated Rebar
SHOULDERS: “PANDROL” #5274 CAST SHOULDERDUCTILE - IRON GRADE #65-45-12
RUNNING STRIPS: 3/16" UHMW POLYETHYLENE
CLIPS: “PANDROL” #E2055 CLIPS - SPRING STEEL
INSULATORS: “PANDROL” #4263THERMOPLASTIC / NYLON
EXPOSED SURFACE: FORM CAST CONCRETE.Optional: Hydrozo “Enviroseal” #40 Surface Treatment
DESIGN LOADING:COOPER E-80 WITH 60% IMPACT
“PANDROL”RAG STEM
SHOULDER
T M
STARTRACK II x 17'6"WEIGHT = 22,000 lbs.
(Plants Nationwide)1-800-316-1660
8’-0”
3’-10 1/2”
1’-1 1/2
”
1’-1 1/2
”
11 1/4
”
11 1/4
”
17’ -6”
1’ -2”
1:40 RAIL CANTTO CENTER
NON-SKID3/16" DIAMOND
PLATE PATTERN
11
RAIL BLOCK-OUTHEIGHT EQUALS
RAIL HEIGHT
GROUT PLUGS(5 TYPICAL)
3/16" UHMWPOLYETHYLENE
NYLON INSULATORTYPE P10
“PANDROL” BRAND RAILCLIP TYPE “E 2055’
RAIL DETAIL
MATERIALS:CONCRETE: THE MINIMUM 28 DAY STRENGTH SHALL
BE 6000 PSI. Optional: Special design mix utilizing Micro-Silica.Optional: W. R. Grace’s “D.C.I.” additive
in lieu of epoxy reinforcing
REBAR: ASTM A615 GRADE 60 AND POST-TENSIONING TENDONS
Optional: Epoxy-coated Rebar
SHOULDERS: “PANDROL” #5274 CAST SHOULDERDUCTILE - IRON GRADE #65-45-12
RUNNING STRIPS: 3/16" UHMW POLYETHYLENE
CLIPS: “PANDROL” #E2055 CLIPS - SPRING STEEL
INSULATORS: “PANDROL” #4263THERMOPLASTIC / NYLON
EXPOSED SURFACE: FORM CAST CONCRETE.Optional: Hydrozo “Enviroseal” #40 Surface Treatment
DESIGN LOADING:COOPER E-80 WITH 60% IMPACT
“PANDROL”RAG STEM
SHOULDER
T M
STARTRACK II x 17'6"WEIGHT = 22,000 lbs.
(Plants Nationwide)1-800-316-1660
8’-0”
3’-10 1/2”
1’-1 1/2
”
1’-1 1/2
”
11 1/4
”
11 1/4
”
17’ -6”
1’ -2”
1:40 RAIL CANTTO CENTER
NON-SKID3/16" DIAMOND
PLATE PATTERN
11
RAIL BLOCK-OUTHEIGHT EQUALS
RAIL HEIGHT
GROUT PLUGS(5 TYPICAL)
3/16" UHMWPOLYETHYLENE
NYLON INSULATORTYPE P10
“PANDROL” BRAND RAILCLIP TYPE “E 2055’
RAIL DETAIL
MATERIALS:CONCRETE: THE MINIMUM 28 DAY STRENGTH SHALL
BE 6000 PSI. Optional: Special design mix utilizing Micro-Silica.Optional: W. R. Grace’s “D.C.I.” additive
in lieu of epoxy reinforcing
REBAR: ASTM A615 GRADE 60 AND POST-TENSIONING TENDONS
Optional: Epoxy-coated Rebar
SHOULDERS: “PANDROL” #5274 CAST SHOULDERDUCTILE - IRON GRADE #65-45-12
RUNNING STRIPS: 3/16" UHMW POLYETHYLENE
CLIPS: “PANDROL” #E2055 CLIPS - SPRING STEEL
INSULATORS: “PANDROL” #4263THERMOPLASTIC / NYLON
EXPOSED SURFACE: FORM CAST CONCRETE.Optional: Hydrozo “Enviroseal” #40 Surface Treatment
DESIGN LOADING:COOPER E-80 WITH 60% IMPACT
“PANDROL”RAG STEM
SHOULDER
T M
STARTRACK II x 17'6"WEIGHT = 22,000 lbs.
(Plants Nationwide)1-800-316-1660
8’-0”
3’-10 1/2”
1’-1 1/2
”
1’-1 1/2
”
11 1/4
”
11 1/4
”
17’ -6”
1’ -2”
1:40 RAIL CANTTO CENTER
NON-SKID3/16" DIAMOND
PLATE PATTERN
11
RAIL BLOCK-OUTHEIGHT EQUALS
RAIL HEIGHT
GROUT PLUGS(5 TYPICAL)
3/16" UHMWPOLYETHYLENE
NYLON INSULATORTYPE P10
“PANDROL” BRAND RAILCLIP TYPE “E 2055’
RAIL DETAIL
MATERIALS:CONCRETE: THE MINIMUM 28 DAY STRENGTH SHALL
BE 6000 PSI. Optional: Special design mix utilizing Micro-Silica.Optional: W. R. Grace’s “D.C.I.” additive
in lieu of epoxy reinforcing
REBAR: ASTM A615 GRADE 60 AND POST-TENSIONING TENDONS
Optional: Epoxy-coated Rebar
SHOULDERS: “PANDROL” #5274 CAST SHOULDERDUCTILE - IRON GRADE #65-45-12
RUNNING STRIPS: 3/16" UHMW POLYETHYLENE
CLIPS: “PANDROL” #E2055 CLIPS - SPRING STEEL
INSULATORS: “PANDROL” #4263THERMOPLASTIC / NYLON
EXPOSED SURFACE: FORM CAST CONCRETE.Optional: Hydrozo “Enviroseal” #40 Surface Treatment
DESIGN LOADING:COOPER E-80 WITH 60% IMPACT
“PANDROL”RAG STEM
SHOULDER
T M
STARTRACK II x 17'6"WEIGHT = 22,000 lbs.
(Plants Nationwide)1-800-316-1660
8’-0”
3’-10 1/2”
1’-1 1/2
”
1’-1 1/2
”
11 1/4
”
11 1/4
”
17’ -6”
1’ -2”
1:40 RAIL CANTTO CENTER
NON-SKID3/16" DIAMOND
PLATE PATTERN
11
RAIL BLOCK-OUTHEIGHT EQUALS
RAIL HEIGHT
GROUT PLUGS(5 TYPICAL)
3/16" UHMWPOLYETHYLENE
NYLON INSULATORTYPE P10
“PANDROL” BRAND RAILCLIP TYPE “E 2055’
RAIL DETAIL
MATERIALS:CONCRETE: THE MINIMUM 28 DAY STRENGTH SHALL
BE 6000 PSI. Optional: Special design mix utilizing Micro-Silica.Optional: W. R. Grace’s “D.C.I.” additive
in lieu of epoxy reinforcing
REBAR: ASTM A615 GRADE 60 AND POST-TENSIONING TENDONS
Optional: Epoxy-coated Rebar
SHOULDERS: “PANDROL” #5274 CAST SHOULDERDUCTILE - IRON GRADE #65-45-12
RUNNING STRIPS: 3/16" UHMW POLYETHYLENE
CLIPS: “PANDROL” #E2055 CLIPS - SPRING STEEL
INSULATORS: “PANDROL” #4263THERMOPLASTIC / NYLON
EXPOSED SURFACE: FORM CAST CONCRETE.Optional: Hydrozo “Enviroseal” #40 Surface Treatment
DESIGN LOADING:COOPER E-80 WITH 60% IMPACT
“PANDROL”RAG STEM
SHOULDER
T M
STARTRACK II x 17'6"WEIGHT = 22,000 lbs.
(Plants Nationwide)1-800-316-1660
8’-0”
3’-10 1/2”
1’-1 1/2
”
1’-1 1/2
”
11 1/4
”
11 1/4
”
17’ -6”
1’ -2”
1:40 RAIL CANTTO CENTER
NON-SKID3/16" DIAMOND
PLATE PATTERN
11
A (Plants Nationwide)1-888-965-3227
(Plants Nationwide) 1-888-965-3227
5
4” PVC PERF. WRAPPED W/ FILTER FABRIC TO DRAINAGE STRUCTURE
FILTER FABRIC
3/8” MINUS FINE AGGREGATE
(Plants Nationwide) 1-888-965-3227
5
A (Plants Nationwide)1-888-965-3227
(Plants Nationwide) 1-888-965-3227
5
(Plants Nationwide) 1-888-965-3227
5
(Plants Nationwide) 1-888-965-3227
5
MATERIALS: CONCRETE: THE MINIMUM 28 DAY STRENGTH SHALL BE 6000 PSI. Optional: Special design mix utilizing Micro-Silica. Optional: Corrosion inhibitor additive in lieu of epoxy reinforcing.
REBAR: ASTM A615, GRADE 60. Optional: Epoxy-coated
SHOULDERS: “PANDROL” #6575 CAST SHOULDER DUCTILE - IRON GRADE #65-45-12
RUNNING STRIPS: 3/16” UHMW POLYETHYLENE
CLIPS: “PANDROL” #E2055 CLIPS - SPRING STEEL
INSULATORS: “PANDROL” #7400 THERMOPLASTIC / NYLON
EXPOSED SURFACE: FORM CAST CONCRETE. Optional: Hydrozo “Enviroseal” Surface Treatment
DESIGN LOADING: COOPER E-80 WITH 60% IMPACT
3/16" UHMWPOLYETHYLENE
NYLON INSULATORTYPE P10
“PANDROL” BRAND RAILCLIP TYPE “E 2055’
RAIL DETAIL
MATERIALS:CONCRETE: THE MINIMUM 28 DAY STRENGTH SHALL
BE 5000 PSI.
REBAR: ASTM A615 GRADE 60.Optional: Epoxy-coated
GASKET: 3/4" x 1" NEOPRENE
SHOULDERS: “PANDROL” #5274 CAST SHOULDERDUCTILE - IRON GRADE #65-45-12
RUNNING STRIPS: 3/16" UHMW POLYETHYLENE
CLIPS: “PANDROL” #E2055 CLIPS - SPRING STEEL
INSULATORS: “PANDROL” #4263THERMOPLASTIC / NYLON
ACCESSORIES: (Optional)LADDERS: (PVC MANHOLE STEPS)ROUGH ELECTRICAL, PNEUMATIC, OR HYDRAULIC PIPINGROLLING GRATING SAFETY COVERSNON-SLIP FLOOR SURFACE
DESIGN LOADING:COOPER E-80[Designed in accordance with A.R.E.A. Specifications]
“PANDROL”RAG STEM
SHOULDER
T M
INSPECTION PITWEIGHT = 51,000 lbs. (20’)
(Plants Nationwide)1-800-316-1660
RAIL BYOTHERS
13
3/16" UHMWPOLYETHYLENE
NYLON INSULATORTYPE P10
“PANDROL” BRAND RAILCLIP TYPE “E 2055’
RAIL DETAIL
MATERIALS:CONCRETE: THE MINIMUM 28 DAY STRENGTH SHALL
BE 5000 PSI.
REBAR: ASTM A615 GRADE 60.Optional: Epoxy-coated
GASKET: 3/4" x 1" NEOPRENE
SHOULDERS: “PANDROL” #5274 CAST SHOULDERDUCTILE - IRON GRADE #65-45-12
RUNNING STRIPS: 3/16" UHMW POLYETHYLENE
CLIPS: “PANDROL” #E2055 CLIPS - SPRING STEEL
INSULATORS: “PANDROL” #4263THERMOPLASTIC / NYLON
ACCESSORIES: (Optional)LADDERS: (PVC MANHOLE STEPS)ROUGH ELECTRICAL, PNEUMATIC, OR HYDRAULIC PIPINGROLLING GRATING SAFETY COVERSNON-SLIP FLOOR SURFACE
DESIGN LOADING:COOPER E-80[Designed in accordance with A.R.E.A. Specifications]
“PANDROL”RAG STEM
SHOULDER
T M
INSPECTION PITWEIGHT = 51,000 lbs. (20’)
(Plants Nationwide)1-800-316-1660
RAIL BYOTHERS
13
3/16" UHMWPOLYETHYLENE
NYLON INSULATORTYPE P10
“PANDROL” BRAND RAILCLIP TYPE “E 2055’
RAIL DETAIL
MATERIALS:CONCRETE: THE MINIMUM 28 DAY STRENGTH SHALL
BE 5000 PSI.
REBAR: ASTM A615 GRADE 60.Optional: Epoxy-coated
GASKET: 3/4" x 1" NEOPRENE
SHOULDERS: “PANDROL” #5274 CAST SHOULDERDUCTILE - IRON GRADE #65-45-12
RUNNING STRIPS: 3/16" UHMW POLYETHYLENE
CLIPS: “PANDROL” #E2055 CLIPS - SPRING STEEL
INSULATORS: “PANDROL” #4263THERMOPLASTIC / NYLON
ACCESSORIES: (Optional)LADDERS: (PVC MANHOLE STEPS)ROUGH ELECTRICAL, PNEUMATIC, OR HYDRAULIC PIPINGROLLING GRATING SAFETY COVERSNON-SLIP FLOOR SURFACE
DESIGN LOADING:COOPER E-80[Designed in accordance with A.R.E.A. Specifications]
“PANDROL”RAG STEM
SHOULDER
T M
INSPECTION PITWEIGHT = 51,000 lbs. (20’)
(Plants Nationwide)1-800-316-1660
RAIL BYOTHERS
13
3/16" UHMWPOLYETHYLENE
NYLON INSULATORTYPE P10
“PANDROL” BRAND RAILCLIP TYPE “E 2055’
RAIL DETAIL
MATERIALS:CONCRETE: THE MINIMUM 28 DAY STRENGTH SHALL
BE 5000 PSI.
REBAR: ASTM A615 GRADE 60.Optional: Epoxy-coated
GASKET: 3/4" x 1" NEOPRENE
SHOULDERS: “PANDROL” #5274 CAST SHOULDERDUCTILE - IRON GRADE #65-45-12
RUNNING STRIPS: 3/16" UHMW POLYETHYLENE
CLIPS: “PANDROL” #E2055 CLIPS - SPRING STEEL
INSULATORS: “PANDROL” #4263THERMOPLASTIC / NYLON
ACCESSORIES: (Optional)LADDERS: (PVC MANHOLE STEPS)ROUGH ELECTRICAL, PNEUMATIC, OR HYDRAULIC PIPINGROLLING GRATING SAFETY COVERSNON-SLIP FLOOR SURFACE
DESIGN LOADING:COOPER E-80[Designed in accordance with A.R.E.A. Specifications]
“PANDROL”RAG STEM
SHOULDER
T M
INSPECTION PITWEIGHT = 51,000 lbs. (20’)
(Plants Nationwide)1-800-316-1660
RAIL BYOTHERS
13
A (Plants Nationwide)1-888-965-3227
DETAIL DRAWING FOR
STARTRACK INSPECTION PIT
TYPICAL JOINT DETAILSIDE VIEW
(Plants Nationwide)1-800-316-1660
SECTION A - A
PLAN VIEW AT ENDPLAN VIEW
[OPTIONAL: 5'-0", 10'-0", 15'-0"]
14
6’-4
”
(Plants Nationwide) 1-888-965-3227
5
(Plants Nationwide) 1-888-965-3227
5
(Plants Nationwide) 1-888-965-3227
5
(Plants Nationwide) 1-888-965-3227
5
1-0”MIN.
1-0”MIN.
8” MIN.
9” MIN.
8” MIN.
3” MIN.
6” MIN.
1-1/2”MAX.
1-1/2”MAX.
1-0”MIN.
1-0”MIN.
1-0”MIN.
vARIeSFROST DePTH
4” PvC PeRF. PIPe WRAPPeD W/FILTeR FABRIC TO DRAINAGe STRUCTURe
(aLL OPTIONS)SUITABLe SUBGRADe
(2500 PSF MIN. BeARING)COMPACTeD TO 95% SECTION vIEW
AGGReGATe BASe
SECTION vIEWASPHALT UNDeRLAYMeNT BASe
OPTION 1
SECTION vIEWASPHALT UNDeRLAYMeNT BASe
OPTION 2
GeOTeXT MeMBRANe(BOTTOM & SIDeS)
GeOTeXT MeMBRANe(BOTTOM & SIDeS)
ASPHALT CONCReTe
ASPHALT CONCReTe
STONe (98% COMPACT)
STONe (98% COMPACT)
4” PvC PeRF. PIPe WRAPPeD W/FILTeR FABRIC TO DRAINAGe STRUCTURe
4” PvC PeRF. PIPe WRAPPeD W/FILTeR FABRIC TO DRAINAGe STRUCTURe
FINe AGGReGATe 3/8” MINUS
FINe AGGReGATe 3/8” MINUS
3/8” OPeN GRADeD CRUSHeD STONe
DeNSe GRADeD AGGReGATe(98% COMPACT)
vARIeSFROST DePTH
vARIeSFROST DePTH
1-0”MIN.
1-0”MIN.
A (Plants Nationwide)1-888-965-3227
(Plants Nationwide) 1-888-965-3227
5
1-0”MIN.
vARIeSFROST DePTH
1-0”MIN.
8” MIN.
1-1/2”MAX.
4” PvC PeRF. PIPe WRAPPeD W/FILTeR FABRIC TO DRAINAGe STRUCTURe
FINe AGGReGATe 3/8” MINUS(aLL OPTIONS)SUITABLe SUBGRADe
(2500 PSF MIN. BeARING)COMPACTeD TO 95%
CONTROLLeD LOW-STReNGTH MATeRIAL (PeR ACI 229 R-99)
FLOW FILL(MIN Fc = 100 PSI)
SECTION vIEWCONTROLLeD DeNSITY FILL BASe
B1-
888-
965-
3227
Sta
rTra
ck II
per
form
s fo
r th
e lo
ads
at m
any
ind
ustr
y cr
oss
ing
s.
Sta
rTra
ck II
, HD
is t
he r
ight
p
rod
uct
for
heav
y lo
ads
at
Inte
rmo
dal
Fac
ilitie
s.
1-88
8-96
5-32
27
Sta
rTra
ck II
per
form
s fo
r th
e lo
ads
at m
any
ind
ustr
y cr
oss
ing
s.
Sta
rTra
ck II
, HD
is t
he r
ight
p
rod
uct
for
heav
y lo
ads
at
Inte
rmo
dal
Fac
ilitie
s.
1-88
8-96
5-32
27
Sta
rTra
ck II
per
form
s fo
r th
e lo
ads
at m
any
ind
ustr
y cr
oss
ing
s.
Sta
rTra
ck II
, HD
is t
he r
ight
p
rod
uct
for
heav
y lo
ads
at
Inte
rmo
dal
Fac
ilitie
s.
1-88
8-96
5-32
27
B1-
888-
965-
3227
Sta
rTra
ck II
can
be
cust
om
m
ade
to c
onf
orm
to
rad
ius
trac
k...N
o P
rob
lem
!
Sta
rTra
ck II
, HD
is t
he
per
fect
so
lutio
n fo
r he
avy
cro
ss t
raffi
c.
1-88
8-96
5-32
27
Sta
rTra
ck II
can
be
cust
om
m
ade
to c
onf
orm
to
rad
ius
trac
k...N
o P
rob
lem
!
Sta
rTra
ck II
, HD
is t
he
per
fect
so
lutio
n fo
r he
avy
cro
ss t
raffi
c.
1-88
8-96
5-32
27
Sta
rTra
ck II
can
be
cust
om
m
ade
to c
onf
orm
to
rad
ius
trac
k...N
o P
rob
lem
!
Sta
rTra
ck II
, HD
is t
he
per
fect
so
lutio
n fo
r he
avy
cro
ss t
raffi
c.
1-88
8-96
5-32
27
1-88
8-96
5-32
27A
We
use
cont
inuo
us v
irgin
rubb
er ra
il gr
oove
inse
rts!
(Plants Nationwide) 1-888-965-3227
5
(Plants Nationwide) 1-888-965-3227
5
(Plants Nationwide) 1-888-965-3227
5
(Plants Nationwide) 1-888-965-3227
5
Preliminary Subsurface Investigation(Optional)
Prior to removal of ties and ballast, soil samples shallbe taken by a recognized soil testing laboratory andthrough laboratory analysis, sufficient data is collectedto evaluate the depth of excavation and thickness ofbase required.
STARTRACK Suggested Installation
Procedure
Subgrade Preparation
The resulting subgrade shall be scarified and com-pacted to 95% of its peak dry density. Drainage tileshall then be installed in a trench area, surrounded byopen graded stone or filter fabric. The entire excavated area and sides shall be lined with an approved fabric equal in performance charac-teristics to “TYPAR” style 3401. The base course material shall be applied in 4" lifts compacted to 98% of peak dry intensity. The leveling course (1-1/2" maximum thickness) shall be carefully screeded to the grade shown. Screeded surface to be within +/- 1/4" of grade. Fill and compact entire exca-vation. See Startrack’s “Startrack Base Options” for other acceptable subgrade procedures.
Module Placement
Modules shall be placed on the resulting base as snugas possible to one another and to within +/- 1/4" in alignment, utilizing lifting hardware provided. Butylrubber sealant shall be applied as shown on thedrawing details. Should any screeded surface irregularity becomeevident during placement of modules, the module shallbe removed and the surface corrected.
Rails, ties, asphalt, ballast, and sub ballast will beremoved from an area comprising the length of thecrossing plus 15' on each end and 10' wide (13' widefor HD) to a minimum depth of 12" below precastmodules, or as determined above. If any areas ofpumping or other indications of instability are encoun-tered, they shall be undercut as required and backfilledwith compacted base course material.
Final Completion
Surface the adjacent track construction with new 10'switch ties in the transition area. Install signal wiring inconduit if required. Apply foam backer rod and sealantto all module joints if required. Clean all debris from excavation and apply asphaltpaving alongside, up to and flush with module. Protectall exposed concrete from asphalt roller. Apply asphaltat ends of crossing to provide a 5' transition from tiesurface to module surface (optional). If asphalt is used for rail groove filler, run locomotive across to cut flangeway.
Remove all construction debris from site and leavecompleted crossing in a clean condition. Package andship loaned lifting hardware to plant (freight prepaid.)
Placing and Fastening of Rail
Rail shall then be placed along StarTrack modules on both sides and all rail splicing completed, making sure all polyethylene pads are in place. After laying rail into blockout groove, start rail installation by centering rail between a set of shoul-ders, inserting nylon insulators, and then pull the clips into place over the insulators with the puller provided. Repeat this process throughout the crossing, then connect rail to track rail by normal methods. If neces-sary, adjust final alignment by moving modules with rail jacks or backhoe.
1-888-965-3227
Preliminary Subsurface Investigation(Optional)
Prior to removal of ties and ballast, soil samples shallbe taken by a recognized soil testing laboratory andthrough laboratory analysis, sufficient data is collectedto evaluate the depth of excavation and thickness ofbase required.
STARTRACK Suggested Installation
Procedure
Subgrade Preparation
The resulting subgrade shall be scarified and com-pacted to 95% of its peak dry density. Drainage tileshall then be installed in a trench area, surrounded byopen graded stone or filter fabric. The entire excavated area and sides shall be lined with an approved fabric equal in performance charac-teristics to “TYPAR” style 3401. The base course material shall be applied in 4" lifts compacted to 98% of peak dry intensity. The leveling course (1-1/2" maximum thickness) shall be carefully screeded to the grade shown. Screeded surface to be within +/- 1/4" of grade. Fill and compact entire exca-vation. See Startrack’s “Startrack Base Options” for other acceptable subgrade procedures.
Module Placement
Modules shall be placed on the resulting base as snugas possible to one another and to within +/- 1/4" in alignment, utilizing lifting hardware provided. Butylrubber sealant shall be applied as shown on thedrawing details. Should any screeded surface irregularity becomeevident during placement of modules, the module shallbe removed and the surface corrected.
Rails, ties, asphalt, ballast, and sub ballast will beremoved from an area comprising the length of thecrossing plus 15' on each end and 10' wide (13' widefor HD) to a minimum depth of 12" below precastmodules, or as determined above. If any areas ofpumping or other indications of instability are encoun-tered, they shall be undercut as required and backfilledwith compacted base course material.
Final Completion
Surface the adjacent track construction with new 10'switch ties in the transition area. Install signal wiring inconduit if required. Apply foam backer rod and sealantto all module joints if required. Clean all debris from excavation and apply asphaltpaving alongside, up to and flush with module. Protectall exposed concrete from asphalt roller. Apply asphaltat ends of crossing to provide a 5' transition from tiesurface to module surface (optional). If asphalt is used for rail groove filler, run locomotive across to cut flangeway.
Remove all construction debris from site and leavecompleted crossing in a clean condition. Package andship loaned lifting hardware to plant (freight prepaid.)
Placing and Fastening of Rail
Rail shall then be placed along StarTrack modules on both sides and all rail splicing completed, making sure all polyethylene pads are in place. After laying rail into blockout groove, start rail installation by centering rail between a set of shoul-ders, inserting nylon insulators, and then pull the clips into place over the insulators with the puller provided. Repeat this process throughout the crossing, then connect rail to track rail by normal methods. If neces-sary, adjust final alignment by moving modules with rail jacks or backhoe.
1-888-965-3227
Preliminary Subsurface Investigaton(Optional)
Prior to removal of ties and ballast, soil samples shall be taken by a recognized soil testing laboratory and through laboratory analysis, sufficient data is collected to evaluate the depth of excavation and thickness of base required.
Subgrade Preparation
Rails, ties, asphalt, ballast, and sub ballast will be removed from an area comprising the length of the crossing plus 15’ on each end and 10’ wide (13’ wide for HD) to a minimum depth of 12” below precast modules, or as determined above. If any areas of pumping or other indications of instability are encountered, they shall be undercut as required and backfilled with compacted base course material.
The resulting subgrade shall be scarified and compacted to 95% of its peak dry density. Drainage tile shall then be installed in a trench area, surrounded by open graded stone or filter fabric.
The entire excavated area and sides shall be lined with an approved fabric equal in performance characteristics to “TYPAR” style 3401.
The base course material shall be applied in 4” lifts compacted to 98% of peak dry intensity. The leveling course (1-1/2” maximum thickness) shall be carefully screeded to the grade shown. Screeded surface to be within +/- 1/4” of grade. Fill and compact entire excavation. See Startrack’s “Startrack Base Options” for other acceptable subgrade procedures.
Module Placement
Modules shall be placed on the resulting base as snug as possible to one another and to within +/- 1/4” in alignment, utilizing lifting hardware provided. Butyl rubber sealant shall be applied as shown on the drawing details.
Should any screeded surface irregularity become evident during placement of modules, the module shall be removed and the surface corrected.
Placing and Fastening of Rail
Rail shall then be placed along StarTrack modules on both sides and all rail splicing completed, making sure all polyethylene pads are in place.
After laying rail into blockout groove, start rail installation by centering rail between a set of shoulders, inserting nylon insulators, and then pull the clips into place over the insulators with the puller provided. Repeat this process throughout the crossing, then connect rail to track rail by normal methods. If necessary, adjust final alignment by moving modules with rail jacks or backhoe.
Placing of Rail Groove Filler
Install rubber rail groove filler according to Startrack’s “rail Groove Filler Installation Instructions for Startrack Rubber Inserts.”
Final Completion
Surface the adjacent track construction with new 10’ switch ties in the transition area. Install signal wiring in conduit if required. Apply foam backer rod and sealant to all module joints if required.
Clean all debris from excavation and apply asphalt paving alongside, up to and flush with module. Protect all exposed concrete from asphalt roller. Apply asphalt at ends of crossing to provide a 5’ transition from tie surface to module surface (optional). If asphalt is used for rail groove filler, run locomotive across to cut flangeway.
Remove all construction debris from site and leave completed crossing in a clean condition. Package and ship loaned lifting hardware to plant (freight prepaid.)
Thank YouBenefits of StartrackStartrack IIStartrack II HDStartrack II x 7'-6"Startrack II x 17'-6"Inspection PitStartrack Base OptionsIndustry, IntermodalCurved Crossings, Heavy LoadsImproved Rail Groove InsertsSuggested InstallationInsert AssembliesRubber Inserts InstallationJoint Gap Filler Strip Installation