1
0.15 Sobrecimiento fc:175 kg/cm2 Junta e=2.50cm 1.40 0.23 0.60 0.50 0.15 0.15 ZC-03 VEREDA AFIRMADO COMPACTADO 1.50 PISO FALSO PISO NPT+1237.50 CORTE 3-3 RELLENO MATERIAL PROPIO 0.20 0.65 0.30 AFIRMADO COMPACTADO RELLENO MATERIAL PROPIO 1.80 CORTE 1-1 0.10 0.15 Sobrecimiento fc:175 kg/cm2 Junta e=2.50cm 2.40 VER EN PLANTA 0.50 0.15 0.15 ZC-02 VEREDA AFIRMADO COMPACTADO PISO FALSO PISO NPT+1237.50 CORTE 2-2 RELLENO MATERIAL PROPIO 0.20 0.65 1.50 0.30 AFIRMADO COMPACTADO RELLENO MATERIAL PROPIO 0.13 3/8''@0.25 CUADRO DE COLUMNAS TIPO 1er NIVEL C1 C2 DE PORTICO DE PORTICO C-A C3 0.25 DE PORTICO 0.25 0.25 0.50 0.50 CT: 0.80 x 0.50 16 Ø5/8 CONFINAMIENTO 0.10 DISTORSION ABSOLUTO DESPLAZAMIENTO 1er PISO DESPLAZAMIENTOS (cm) X ANGULAR DESPLAZAMIENTOS (cm) Y DISTORSION ABSOLUTO DESPLAZAMIENTO ANGULAR 0.0002 0.09 0.0058 2.34 TABIQUERIA CONFINADA MUROS PORTANTES CL: 0.50 x 0.50 8 Ø5/8+4 Ø3/4 0.25 x 0.40 6 Ø5/8 C-A: 0.25 x 0.13 4 Ø3/8 0.45 0.15 0.40 0.15 2 Ø 6mm CADA 3HILADAS VC (0.30x0.70) SOBRECIMIENTO C-B V-S JUNTA E=1'' (colocar espuma plastica 2'' y sellar con jebe microporoso de 1'' espesor) Ø1/4'' [email protected] [email protected] [email protected] C-B(0.13x0.25) ESC. 1:25 .25 .13 V-S(0.13x0.10) .13 .10 ESCALA 1:25 ZAPATA CONTINUA 0.25 ESC. 1:25 2Ø3/8'' 4Ø3/8'' 1/4'' [email protected], [email protected], Rto @0.20 1/4'' @0.20 CONFINAMIENTO DE ALFEIZAR 0.95 0.20 0.50 0.15 Sobrecimiento fc:175 kg/cm2 Junta e=2.50cm 1.40 0.23 0.50 0.15 0.15 ZC-04 PISO FALSO PISO NPT+1237.50 CORTE 5-5 RELLENO MATERIAL PROPIO 0.20 0.65 0.30 AFIRMADO COMPACTADO 0.15 Sobrecimiento fc:175 kg/cm2 0.80 0.13 0.60 0.15 0.15 1.50 PISO FALSO PISO NPT+1237.50 CORTE 4-4 RELLENO MATERIAL PROPIO 0.75 0.30 AFIRMADO COMPACTADO RELLENO MATERIAL PROPIO PISO FALSO PISO AFIRMADO COMPACTADO 3/8''@0.25 NIVEL +1235.85 NFC-1.50m NIVEL +1236.55 NVC-0.80m NIVEL +1237.35 NTN+0.00m Concreto Ciclopeo C:H 1:8+30%PM Modulo - Laboratorio CUADRO VIGAS DE CIMENTACION TIPO DIMENSIONES ZC-1 8.75x1.80 x 0.50 REFUERZO ZC-2 8.75x 2.50 x 0.50 ZC-3 8.75 x1.60x 0.50 1Ø1/2'' @0.15m 1Ø1/2'' @0.15m ZC-4 8.75 x1.60x 0.50 EJE X-X EJE Y-Y SE COLOCARA SOLADO DE 10cm 0.15 Sobrecimiento fc:175 kg/cm2 Junta e=2.50cm VER EN PLANTA 0.50 0.15 0.15 ZC-01 VEREDA AFIRMADO COMPACTADO PISO FALSO PISO NPT+1237.50 RELLENO MATERIAL PROPIO 0.20 0.65 1.50 0.30 AFIRMADO COMPACTADO RELLENO MATERIAL PROPIO 0.13 3/8''@0.25 0.10 1Ø1/2'' @0.15m 1Ø1/2'' @0.15m EJE X-X EJE Y-Y 1Ø1/2'' @0.15m 1Ø1/2'' @0.15m EJE X-X EJE Y-Y 0.25 0.25 0.25 0.25 1Ø1/2'' @0.15m 1Ø1/2'' @0.15m EJE X-X EJE Y-Y 0.40 1.50 solado 1:10 solado 1:10 CORTE 2"-2" ESC 1:25 CORTE 1"-1" ESC 1:25 0.13 0.25 C-2 C-2 C-2 C-1 C-2 C3 C3 A .58 1.40 .58 1.08 2.40 1.08 1 ZAPATA CONTINUA ZC-02 VC(0.30x0.70) VC(0.30x0.70) VC(0.30x0.70) VC(0.30x0.70) VC(0.30x0.70) VC(0.30x0.70) VC(0.30x0.70) VC(0.30x0.70) VC(0.30x0.70) VC(0.30x0.70) 2 3 B C D E F G .50 2.80 .40 2.80 .50 .78 4.65 1.80 3.50 3.50 .78 .50 3.08 .80 .80 3.05 .80 .50 6.60 .80 6.90 .80 6.05 1.40 3.98 3.85 3.85 3.85 3.85 4.00 A .58 1.40 .58 B C D E F G .50 3.08 .80 3.05 .80 3.05 .80 3.05 .80 3.05 .80 3.08 .50 6.60 .80 6.90 .80 6.05 1.40 3.98 3.85 3.85 3.85 3.85 3.98 1.08 2.40 1.08 1 2 3 .50 2.80 .40 2.80 .50 .58 4.85 1.40 3.50 3.50 .58 ZAPATA CONTINUA ZC-01 ZAPATA CONTINUA ZC-03 ZAPATA CONTINUA ZC-04 2 2 3 3 4 4 5 5 5 5 AULA 01 NPT+0.15 AULA 02 NPT+0.15 AULA 03 NPT+0.15 PLANTA DE CIMENTACION ESC 1:50 4 4 4 4 4 4 2 2 2 2 2 2 2 2 2 2 CA .80 .80 1 1 1 1 1 1 1 1 VC(0.30x0.70) VC(0.30x0.70) VC(0.30x0.70) VC(0.30x0.70) VC(0.30x0.70) VC(0.30x0.70) 2" 2" CA CA CA CA CA CA CA CA CA CA CA CA Adjuntar concimentacion de aulas. CA CA CA CA CA CA CA CA CA CA CA 0.80 0.25 0.25 0.25 0.50 3.05 .80 3.05 .80 3.05 .80 3.05 .80 3.08 3/8'' [email protected], [email protected], [email protected], Rto @0.25 a/e 3/8'' [email protected], [email protected], [email protected], Rto @0.25 a/e 3/8'' [email protected], [email protected], [email protected], Rto @0.25 a/e 1/4'' [email protected], [email protected], Rto @0.20 CA CA CA CA CA CA C-B 0.15 0.13 1/4'' [email protected], [email protected], Rto @0.20 Acero de 5/8'' Acero de 3/4'' Acero de 5/8'' Acero de 3/4'' CONFINAMIENTO L PARA VIGAS Y ALIGERADOS ESPECIFICACIONES TECNICAS í í A- MATERIALES: B- RECUBRIMIENTOS: D- NORMAS Y REGLAMENTOS: Ñ Ñ E- PARAMETROS SISMICOS: F- DETALLE DE ESTRIBOS: G- GANCHOS ESTANDAR: H- TRASLAPES Y EMPALMES: »» »» »» »» »» »» »» VIGA VIGA PARA COLUMNAS 2L/3 L/6 L/6 L m L/3 L/3 L/3 m m L/4 L/4 L/4 L/4 H C- CONDICIONES DE CIMENTACION: R L 3/8'' [email protected], [email protected], [email protected] Rto @0.25 3/8'' [email protected], [email protected], [email protected] Rto @0.25 3/8'' [email protected], [email protected], [email protected] Rto @0.25 3/8'' [email protected], [email protected], [email protected] Rto @0.25 1" 1" 3/8'' [email protected], [email protected], [email protected] Rto @0.25 3/8'' [email protected], [email protected], [email protected] Rto @0.25 1.50 1.80 CORTE 1´-1´ 0.70 SUB CIMIENTO fc' 100kg/cm2 +30% P.M 0.15 Sobrecimiento fc:175 kg/cm2 Junta e=2.50cm VER EN PLANTA 0.50 0.15 0.15 ZC-01 VEREDA AFIRMADO COMPACTADO PISO FALSO PISO NPT+1237.50 RELLENO MATERIAL PROPIO 0.20 0.65 1.50 0.30 AFIRMADO COMPACTADO RELLENO MATERIAL PROPIO 0.13 3/8''@0.25 0.10 0.25 3/8'' [email protected], [email protected], [email protected] Rto @0.25 solado 1:10 0.15 Sobrecimiento fc:175 kg/cm2 Junta e=2.50cm 1.40 0.23 0.60 0.50 0.15 0.15 ZC-03 VEREDA AFIRMADO COMPACTADO 1.50 PISO FALSO PISO NPT+1237.50 CORTE 3´-3´ RELLENO MATERIAL PROPIO 0.20 0.65 0.70 SUB CIMIENTO fc' 100kg/cm2 +30% P.M 0.30 AFIRMADO COMPACTADO RELLENO MATERIAL PROPIO 0.70 0.25 3/8'' [email protected], [email protected], [email protected] Rto @0.25 solado 1:10 C-1 C-1 C-1 C-1 C-1 C-1 C-1 C-1 C-1 0.30 NPT+1237.50 1.50 C-A: 0.15 x 0.13 4 Ø3/8 0.09 0.03 0.25 23.40 5.9500 CIMIENTO CORRIDO fc' 100kg/cm2 +30% P.M NIVEL +1235.85 NFC-1.50m NIVEL +1236.55 NVC-0.80m NIVEL +1237.35 NTN+0.00m 0.40 ALCALDE: JULIO - 2019 FECHA : Dpto : Distrito : Provincia : Escala : LAMBAYEQUE CHICLAYO CHONGOYAPE LAMINA: PROYECTO: PLANO: 2019 - 2022 Region : LAMBAYEQUE ELABORADO POR: IND. ESPECIALIDAD: '5647%674#5 MUNICIPALIDAD DISTRITAL DE CHONGOYAPE ROGER WILLIAM SANTACRUZ FLORES "RECUPERACIÓN DEL SERVICIO EDUCATIVO EN LA I.E. N° 11537 WADINGTON BAJO DEL DISTRITO DE CHONGOYAPE - PROVINCIA DE CHICLAYO - DEPARTAMENTO DE LAMBAYEQUE" GERENCIA DE DESARROLLO URBANO Y RURAL JEFE DE PROYECTO: ARQ./ING. ESPECIALISTA: ARQ./ING. COMPONENTE: E-13 PLANTA DE CIMENTACIÓN Y DETALLES - LABORATORIO OBRAS EXTERIORES
Transcript

0.15

Sobrecimiento

fc:175 kg/cm2

Junta e=2.50cm

1.40

0.23

0.60

0.50

0.15

0.15

ZC-03

VEREDA

AFIRMADOCOMPACTADO

1.50

PISOFALSO PISO

NPT+1237.50

CORTE 3-3

RELLENO MATERIALPROPIO

0.20

0.65

0.30

AFIRMADOCOMPACTADO

RELLENO MATERIALPROPIO

1.80

CORTE 1-1

0.10

0.15

Sobrecimiento

fc:175 kg/cm2

Junta e=2.50cm

2.40

VER EN PLANTA

0.50

0.15

0.15

ZC-02

VEREDA

AFIRMADOCOMPACTADO

PISOFALSO PISO

NPT+1237.50

CORTE 2-2

RELLENO MATERIALPROPIO

0.20

0.65

1.50

0.30

AFIRMADOCOMPACTADO

RELLENO MATERIALPROPIO

0.13

3/8''@0.25

CUADRO DE COLUMNAS

TIPO 1er NIVEL

C1

C2

DE P

ORT

ICO

DE P

ORT

ICO

C-A

C30.25

DE P

ORT

ICO

0.25

0.25

0.50

0.50

CT: 0.80 x 0.5016 Ø5/8

CONF

INAM

IENT

O

0.10

DISTORSION ABSOLUTO

DESPLAZAMIENTO

1er PISO

DESPLAZAMIENTOS (cm) X

ANGULAR

DESPLAZAMIENTOS (cm) YDISTORSION

ABSOLUTO DESPLAZAMIENTO

ANGULAR

0.00020.090.00582.34

TABIQUERIA CONFINADA

MUROS PORTANTES

CL: 0.50 x 0.508 Ø5/8+4 Ø3/4

0.25 x 0.406 Ø5/8

C-A: 0.25 x 0.134 Ø3/8

0.45

0.15

0.40

0.15

2 Ø 6mm

CADA 3HILADAS

VC

(0.30x0.70)

SOBRECIMIENTO

C-B

V-S

JUNTA E=1'' (colocar espuma plastica 2'' y

sellar con jebe microporoso de 1'' espesor)

Ø1/

4'' 1

@0.

05 5

@0.

10 R

to@

0.20

C-B(0.13x0.25)ESC. 1:25

.25

.13

V-S(0.13x0.10).13

.10

ESCALA 1:25

ZAPATA

CONTINUA

0.25

ESC. 1:25

2Ø3/8''

4Ø3/8''

1/4'' [email protected], [email protected], Rto @0.20

1/4'' @0.20

CONFINAMIENTO DE ALFEIZAR

0.95

0.20

0.50

0.15

Sobrecimiento

fc:175 kg/cm2

Junta e=2.50cm

1.40

0.23

0.50

0.15

0.15

ZC-04

PISOFALSO PISO

NPT+1237.50

CORTE 5-5

RELLENO MATERIALPROPIO

0.20

0.65

0.30

AFIRMADOCOMPACTADO

0.15

Sobrecimiento

fc:175 kg/cm2

0.80

0.13

0.60

0.15

0.15

1.50

PISOFALSO PISO

NPT+1237.50

CORTE 4-4

RELLENO MATERIALPROPIO

0.75

0.30

AFIRMADOCOMPACTADO

RELLENO MATERIALPROPIO

PISOFALSO PISO

AFIRMADOCOMPACTADO

3/8''@0.25

NIVEL +1235.85

NFC-1.50m

NIVEL +1236.55

NVC-0.80m

NIVEL +1237.35

NTN+0.00m

Concreto Ciclopeo

C:H 1:8+30%PM

Modulo - Laboratorio

CUADRO VIGAS DE CIMENTACION

TIPO DIMENSIONESZC-1 8.75x1.80 x 0.50

REFUERZO

ZC-2 8.75x 2.50 x 0.50

ZC-3 8.75 x1.60x 0.50

1Ø1/2'' @0.15m1Ø1/2'' @0.15m

ZC-4 8.75 x1.60x 0.50

EJE X-XEJE Y-Y

SE COLOCARA SOLADO DE 10cm

0.15

Sobrecimiento

fc:175 kg/cm2

Junta e=2.50cm

VER EN PLANTA

0.50

0.15

0.15

ZC-01

VEREDA

AFIRMADOCOMPACTADO

PISOFALSO PISO

NPT+1237.50

RELLENO MATERIALPROPIO

0.20

0.65

1.50

0.30

AFIRMADOCOMPACTADO

RELLENO MATERIALPROPIO

0.13

3/8''@0.25

0.10

1Ø1/2'' @0.15m1Ø1/2'' @0.15m

EJE X-XEJE Y-Y

1Ø1/2'' @0.15m1Ø1/2'' @0.15m

EJE X-XEJE Y-Y

0.25 0.25

0.25 0.25

1Ø1/2'' @0.15m1Ø1/2'' @0.15m

EJE X-XEJE Y-Y

0.40

1.50

solado 1:10

solado 1:10

CORTE 2"-2"ESC 1:25

CORTE 1"-1"ESC 1:25

0.13

0.25

C-2 C-2

C-2 C-1 C-2

C3C3

A

.58

1.40

.58

1.08

2.40

1.08

1

ZAPATA CONTINUA ZC-02

VC(0.30x0.70) VC(0.30x0.70) VC(0.30x0.70) VC(0.30x0.70) VC(0.30x0.70) VC(0.30x0.70)

VC

(0.30x0.70)

VC

(0.30x0.70)

VC

(0.30x0.70)

VC

(0.30x0.70)

2

3

B C D E F G

.50

2.80

.40

2.80

.50

.78

4.65

1.80

3.50

3.50

.78

.50 3.08 .80 .80 3.05 .80 .50

6.60 .80 6.90 .80 6.05 1.40

3.98 3.85 3.85 3.85 3.85 4.00

A

.58

1.40

.58

B C D E F G

.50 3.08 .80 3.05 .80 3.05 .80 3.05 .80 3.05 .80 3.08 .50

6.60 .80 6.90 .80 6.05 1.40

3.98 3.85 3.85 3.85 3.85 3.98

1.08

2.40

1.08

1

2

3

.50

2.80

.40

2.80

.50

.58

4.85

1.40

3.50

3.50

.58

ZAPATA CONTINUA ZC-01ZA

PATA

CONT

INUA

ZC-0

3

ZAPA

TA CO

NTIN

UA ZC

-04

2

2

3´ 3´

3 3

4 4 5 5

5 5

AULA 01NPT+0.15

AULA 02NPT+0.15

AULA 03NPT+0.15

PLANTA DE CIMENTACIONESC 1:50

4 4

4 4

4 4

2

2

2

2

2

2

2

2

2

2

CA

.80 .80

1

1

1

1

1

1

1

1

VC(0.30x0.70) VC(0.30x0.70) VC(0.30x0.70) VC(0.30x0.70) VC(0.30x0.70) VC(0.30x0.70)

2"2"

CA CA CA CA

CA CA

CA CA CA CA CA CA

Adju

ntar

con

cim

enta

cion

de

aula

s.

CA CA

CA CACA CA

CA

CA

CA

CA

CA

0.80

0.25

0.25

0.25

0.50

3.05 .80 3.05 .80 3.05 .80 3.05 .80 3.08

3/8'' [email protected], [email protected], [email protected],

Rto @0.25 a/e

3/8'' [email protected], [email protected], [email protected],

Rto @0.25 a/e

3/8'' [email protected], [email protected], [email protected],

Rto @0.25 a/e

1/4'' [email protected], [email protected],

Rto @0.20

CA CA CA CA CA CA

C-B 0.15

0.13

1/4'' [email protected], [email protected],

Rto @0.20

Acero de 5/8''

Acero de 3/4''

Acero de 5/8''

Acero de 3/4''

CONF

INAM

IENT

O

L

PARA VIGAS Y ALIGERADOS

ESPECIFICACIONES TECNICAS

í

í

A- MATERIALES:

B- RECUBRIMIENTOS:

D- NORMAS Y REGLAMENTOS:

Ñ

Ñ

E- PARAMETROS SISMICOS:

F- DETALLE DE ESTRIBOS:

G- GANCHOS ESTANDAR:

H- TRASLAPES Y EMPALMES:

»»

»»

»»

»»

»»

»»

»»

VIGA

VIGA

PARA COLUMNAS

2L/3

L/6

L/6

Lm

L/3 L/3 L/3

m

m

L/4 L/4 L/4 L/4

H

C- CONDICIONES DE CIMENTACION:

R

L

3/8'' [email protected], [email protected], [email protected] Rto @0.253/8'' [email protected], [email protected], [email protected] Rto @0.25

3/8'' [email protected], [email protected], [email protected] Rto @0.25

3/8'' [email protected], [email protected], [email protected] Rto @0.25

1"1"

3/8'' [email protected], [email protected], [email protected] Rto @0.253/8'' [email protected], [email protected], [email protected] Rto @0.25

1.50

1.80

CORTE 1´-1´

0.70

SUB CIMIENTOfc' 100kg/cm2+30% P.M

0.15

Sobrecimiento

fc:175 kg/cm2

Junta e=2.50cm

VER EN PLANTA

0.50

0.15

0.15

ZC-01

VEREDA

AFIRMADOCOMPACTADO

PISOFALSO PISO

NPT+1237.50

RELLENO MATERIALPROPIO

0.20

0.65

1.50

0.30

AFIRMADOCOMPACTADO

RELLENO MATERIALPROPIO

0.13

3/8''@0.25

0.10

0.25

3/8'' [email protected], [email protected], [email protected] Rto @0.25

solado 1:10

0.15

Sobrecimiento

fc:175 kg/cm2

Junta e=2.50cm

1.40

0.23

0.60

0.50

0.15

0.15

ZC-03

VEREDA

AFIRMADOCOMPACTADO

1.50

PISOFALSO PISO

NPT+1237.50

CORTE 3´-3´

RELLENO MATERIALPROPIO

0.20

0.65

0.70

SUB CIMIENTOfc' 100kg/cm2+30% P.M

0.30

AFIRMADOCOMPACTADO

RELLENO MATERIALPROPIO

0.70

0.25

3/8'' [email protected], [email protected], [email protected] Rto @0.25

solado 1:10

C-1C-1C-1C-1

C-1C-1C-1C-1 C-1

0.30

NPT+1237.50

1.50

C-A: 0.15 x 0.134 Ø3/8

0.09

0.03

0.25

23.40

5.9500

CIMIENTO CORRIDOfc' 100kg/cm2 +30% P.M

NIVEL +1235.85

NFC-1.50m

NIVEL +1236.55

NVC-0.80m

NIVEL +1237.35

NTN+0.00m

0.40

ALCALDE:

JULIO - 2019FECHA :

Dpto :

Distrito :

Provincia :

Escala :

LAMBAYEQUE

CHICLAYO

CHONGOYAPE

LAMINA:

PROYECTO:

PLANO:

2019 - 2022

Region :LAMBAYEQUE

ELABORADO POR:

IND.

ESPECIALIDAD:

MUNICIPALIDAD DISTRITAL DE CHONGOYAPE

ROGERWILLIAM

SANTACRUZFLORES

"RECUPERACIÓN DEL SERVICIO EDUCATIVO EN LA I.E. N° 11537 WADINGTONBAJO DEL DISTRITO DE CHONGOYAPE - PROVINCIA DE CHICLAYO -

DEPARTAMENTO DE LAMBAYEQUE"

GERENCIA DE DESARROLLO URBANO Y RURAL

JEFE DE PROYECTO:

ARQ./ING.ESPECIALISTA:

ARQ./ING.

COMPONENTE:

E-13

PLANTA DE CIMENTACIÓN Y DETALLES - LABORATORIOOBRAS EXTERIORES

AutoCAD SHX Text
ESC 1:25
AutoCAD SHX Text
1/2''@0.15
AutoCAD SHX Text
ESC 1:25
AutoCAD SHX Text
ESC 1:25
AutoCAD SHX Text
1/2''@0.15
AutoCAD SHX Text
ESC 1:25
AutoCAD SHX Text
1/2''@0.15
AutoCAD SHX Text
ESC 1:25
AutoCAD SHX Text
1/2''@0.15
AutoCAD SHX Text
1/2''@0.15
AutoCAD SHX Text
5/8''@0.15
AutoCAD SHX Text
1/2''@0.15
AutoCAD SHX Text
1/2''@0.15
AutoCAD SHX Text
2 5/8''+2 1/2''
AutoCAD SHX Text
2 5/8''+2 1/2''
AutoCAD SHX Text
2 5/8''+2 1/2''
AutoCAD SHX Text
2 5/8''+2 1/2''
AutoCAD SHX Text
1 1/2'' de eje de columna 1.5m A/E.
AutoCAD SHX Text
1 3/4'' de eje de columna 1.5m A/E.
AutoCAD SHX Text
L
AutoCAD SHX Text
10cm
AutoCAD SHX Text
R
AutoCAD SHX Text
min
AutoCAD SHX Text
2.0cm.
AutoCAD SHX Text
%%C
AutoCAD SHX Text
1/4"
AutoCAD SHX Text
15cm
AutoCAD SHX Text
2.0cm.
AutoCAD SHX Text
3/8"
AutoCAD SHX Text
10cm
AutoCAD SHX Text
6mm.
AutoCAD SHX Text
2.0cm.
AutoCAD SHX Text
CONCRETO: SOLADOS DE 4'' :f'c 100 Kg/cm² f'c 100 Kg/cm² SUBCIMIENTO :f'c 100 Kg/cm²+30%PM SUBCIMIENTO :f'c 100 Kg/cm²+30%PM :f'c 100 Kg/cm²+30%PM f'c 100 Kg/cm²+30%PM CIMIENTOS CORRIDOS :f'c 100 Kg/cm²+30%PM f'c 100 Kg/cm²+30%PM SOBRECIMIENTOS :f'c 175 Kg/cm² f'c 175 Kg/cm² ZAPATAS CONTINUAS :f'c 210 Kg/cm² f'c 210 Kg/cm² VIGAS DE CIMENTACION :f'c 210 Kg/cm² f'c 210 Kg/cm² COLUMNAS Y VIGAS :f'c 210 Kg/cm² f'c 210 Kg/cm² ESCALERAS :f'c 210 Kg/cm² f'c 210 Kg/cm² LOSAS ALIGERADAS : f'c 210 Kg/cm² f'c 210 Kg/cm² ACERO DE REFUERZO :fy 4200 Kg/cm² fy 4200 Kg/cm² ALBAÑILERIA: ÑILERIA: ILERIA: MURO DE ARRIOSTRE :Ladrillo TIPO IVLadrillo TIPO IVf'b=130 Kg/cm², f'm=65 Kg/cm² - 30% de vacíos os TABIQUES:Ladrillo TIPO III Ladrillo TIPO III f'b=95 Kg/cm², f'm=45 Kg/cm² - 30% de vacíos os
AutoCAD SHX Text
LOSAS Y ESCALERAS : 2.5 cm 2.5 cm VIGAS Y COLUMNAS ESTRUCTURALES : 4.0 cm 4.0 cm VIGAS Y COLUMNAS DE ALBAÑILERIA : 2.5 cm ÑILERIA : 2.5 cm ILERIA : 2.5 cm 2.5 cm FONDOS DE VIGA Y ZAPATA SOBRE SOLADOS : 5.0 cm 5.0 cm COSTADOS DE ZAPATAS NO ENCOFRADOS: 7.5 cm 7.5 cm COSTADO DE CIMENTACIONES ENCOFRADOS: 5.0 cm. 5.0 cm. »» Los recubrimientos se lograran mediante el Los recubrimientos se lograran mediante el empleo de dados de concreto o mortero «« ««
AutoCAD SHX Text
II. ESTRATO DE APOYO DE CIMENTACION: SUELO LIMO ARENOSO DE BAJA PLASTICIDAD (ML) III. PARAMETROS DE DISEÑO DE LA CIMENTACION: ÑO DE LA CIMENTACION: O DE LA CIMENTACION: PROFUNDIDAD DE CIMENTACION Df=1.50m. PRESION ADMISIBLE Qa = 0.92 Kg/cm² ASENTAMIENTO ESPERADO = 2.00cm. find IV. find IV. find IV. AGRESIVIDAD DEL SUELO A LA CIMENTACION: GRADO DE AGRESIVIDAD : MODERARO, SE USARA CEMENTO TIPO MS
AutoCAD SHX Text
NORMA E-020 "CARGAS" NORMA E-030 "DISEÑO SISMO-RESISTENTE" O SISMO-RESISTENTE" NORMA E-050 "SUELOS Y CIMENTACIONES" NORMA E-060 "CONCRETO ARMADO" NORMA E-070 "ALBAÑILERIA" ILERIA" REGLAMENTO NACIONAL DE EDIFICACIONES
AutoCAD SHX Text
FACTOR DE ZONA (ZONA 3) :Z=0.35 Z=0.35 FACTOR DE SUELO (TIPO S3) :S=1.20 Tp(s)=1.00 S=1.20 Tp(s)=1.00 TL(s)=1.60 FACTOR DE USO E IMPORTANCIA :U=1.5 U=1.5 FACTOR DE REDUCCION: AULAS +LABORATORIOSEJE X-X :Rx=8EJE X-X :Rx=8Rx=8 EJE Y-Y :Ry=3Ry=3
AutoCAD SHX Text
Acero 3/8" :0.15 m. 0.15 m. Acero 1/2" :0.20 m. 0.20 m. Acero 5/8" :0.25 m. 0.25 m. Acero 3/4" :0.30 m. 0.30 m. Acero 1" :0.40 m. 0.40 m.
AutoCAD SHX Text
PARA BARRAS HORIZONTALES QUE TENGAN POR DEBAJO MAS DE 30cm. DE CONCRETO FRESCO: MULTIPLICAR POR 1.4 LA MULTIPLICAR POR 1.4 LA MULTIPLICAR POR 1.4 LA LONGITUD DE EMPALME. NO SE EMPALMARA MAS DEL 50% DE LA ARMADURA EN ARMADURA EN ARMADURA EN UNA MISMA SECCION NO SE EMPALMARA LA ARMADURA SUPERIOR DE ELEMENTOS ELEMENTOS ELEMENTOS EN VOLADIZO NO SE EMPALMARA LA ARMADURA INFERIOR EN EL TERCIO TERCIO TERCIO CENTRAL EN ELEMENTOS HORIZONTALES, AISLADOS O AISLADOS O AISLADOS O CONTINUOS NO SE EMPALMARA LA ARMADURA SUPERIOR EN APOYOS APOYOS APOYOS CONTINUOS EN ELEMENTOS VERTICALES, LOS EMPALMES SE UBICARAN UBICARAN UBICARAN EN DIFERENTES PARTES FUERA DE LA ZONA DE ZONA DE ZONA DE CONFINAMIENTO. EN CASO DE NO EMPALMARSE EN LAS ZONAS INDICADAS O INDICADAS O INDICADAS O CON LOS PORCENTAJES ESPECIFICADOS, AUMENTAR LA ESPECIFICADOS, AUMENTAR LA ESPECIFICADOS, AUMENTAR LA LONGITUD DE EMPALME UN 70%. EMPALME UN 70%. EMPALME UN 70%.
AutoCAD SHX Text
EMPALMES TRASLAPADOS: TIPO B: 45 Acero 3/8" :m= 0.45 m.Acero 1/2" :m= 0.60 m. m= 0.45 m.Acero 1/2" :m= 0.60 m. Acero 1/2" :m= 0.60 m. m= 0.60 m. 0.60 m. 0.60 m. Acero 5/8" :m= 0.70 m. Acero 3/4" :m= 0.85 m. m= 0.70 m. Acero 3/4" :m= 0.85 m. Acero 3/4" :m= 0.85 m. m= 0.85 m. 0.85 m. 0.85 m. Acero 1" :m= 1.15 m. m= 1.15 m.
AutoCAD SHX Text
I. TIPO DE CIMENTACION: CIMIENTO CORRIDO CON VIGAS DE CONEXION
AutoCAD SHX Text
2 5/8''+2 1/2''
AutoCAD SHX Text
2 3/8''
AutoCAD SHX Text
2 5/8''+2 1/2''
AutoCAD SHX Text
2 5/8''+2 1/2''
AutoCAD SHX Text
2 3/8''
AutoCAD SHX Text
2 5/8''+2 1/2''
AutoCAD SHX Text
2 5/8''+2 1/2''
AutoCAD SHX Text
2 3/8''
AutoCAD SHX Text
2 5/8''+2 1/2''
AutoCAD SHX Text
2 5/8''+2 1/2''
AutoCAD SHX Text
2 3/8''
AutoCAD SHX Text
2 5/8''+2 1/2''
AutoCAD SHX Text
ESC 1:25
AutoCAD SHX Text
1/2''@0.15
AutoCAD SHX Text
1/2''@0.15
AutoCAD SHX Text
2 5/8''+2 1/2''
AutoCAD SHX Text
2 3/8''
AutoCAD SHX Text
2 5/8''+2 1/2''
AutoCAD SHX Text
ESC 1:25
AutoCAD SHX Text
1/2''@0.15
AutoCAD SHX Text
5/8''@0.15
AutoCAD SHX Text
2 5/8''+2 1/2''
AutoCAD SHX Text
2 3/8''
AutoCAD SHX Text
2 5/8''+2 1/2''
OSCAR
Texto tecleado
000042