LCL
Chapter 13Statistical Methods for Quality Control
Statistical Process Control Acceptance Sampling
2 2 Slide
Slide
Quality Terminology
Quality is “the totality of features and characteristics of a product or service that bears on its ability to satisfy given needs.”
Quality assurance refers to the entire system of policies, procedures, and guidelines established by an organization to achieve and maintain quality.
The objective of quality engineering is to include quality in the design of products and processes and to identify potential quality problems prior to production.
Quality control consists of making a series of inspections and measurements to determine whether quality standards are being met.
3 3 Slide
Slide
Statistical Process Control (SPC)
The goal of SPC is to determine whether the process can be continued or whether it should be adjusted to achieve a desired quality level.
If the variation in the quality of the production output is due to assignable causes (operator error, worn-out tooling, bad raw material, . . . ) the process should be adjusted or corrected as soon as possible.
If the variation in output is due to common causes (variation in materials, humidity, temperature, . . . ) which the manager cannot control, the process does not need to be adjusted.
4 4 Slide
Slide
SPC Hypotheses
SPC procedures are based on hypothesis-testing methodology.
The null hypothesis H0 is formulated in terms of the production process being in control.
The alternative hypothesis Ha is formulated in terms of the process being out of control.
As with other hypothesis-testing procedures, both a Type I error (adjusting an in-control process) and a Type II error (allowing an out-of-control process to continue) are possible.
5 5 Slide
Slide
The Outcomes of SPC
Type I and Type II Errors State of Production
Process
H0 True Ha True
Decision In Control Out of Control
Accept H0 Correct Type II
Continue Process DecisionError
Reject H0 Type I Correct
Adjust Process Error Decision
6 6 Slide
Slide
Control Charts
SPC uses graphical displays known as control charts to monitor a production process.
Control charts provide a basis for deciding whether the variation in the output is due to common causes (in control) or assignable causes (out of control).
Two important lines on a control chart are the upper control limit (UCL) and lower control limit (LCL).
These lines are chosen so that when the process is in control there will be a high probability that the sample finding will be between the two lines.
Values outside of the control limits provide strong evidence that the process is out of control.
7 7 Slide
Slide
Types of Control Charts
An x chart is used if the quality of the output is measured in terms of a variable such as length, weight, temperature, and so on.
x represents the mean value found in a sample of the output.
An R chart is used to monitor the range of the measurements in the sample.
A p chart is used to monitor the proportion defective in the sample.
An np chart is used to monitor the number of defective items in the sample.
8 8 Slide
Slide
Interpretation of Control Charts
The location and pattern of points in a control chart enable us to determine, with a small probability of error, whether a process is in statistical control.
A primary indication that a process may be out of control is a data point outside the control limits.
Certain patterns of points within the control limits can be warning signals of quality problems:• Large number of points on one side of
center line.• Six or seven points in a row that indicate
either an increasing or decreasing trend.• . . . and other patterns.
9 9 Slide
Slide
Control Limits for an x Chart
Process Mean and Standard Deviation Known
Process Mean and Standard Deviation Unknown
where:x = overall sample mean
R = average range A2 = a constant that depends on n; taken from
“Factors for Control Charts” table
UCL = 3 x
LCL = 3 x
UCL = x A R 2
LCL = x A R 2
=_
10 10 Slide
Slide
Control Limits for an R Chart
UCL = RD4
LCL = RD3
where:
R = average range D3, D4 = constants that depend on n; found in “Factors for Control Charts” table
_
_
_
11 11 Slide
Slide
Factors for x and R Control Charts
Factors Table (Partial)
n d2 A2 d3 D3 D4
. . . . . .6 2.534 0.483 0.848 0 2.0047 2.704 0.419 0.833 0.076 1.9248 2.847 0.373 0.820 0.136 1.8649 2.970 0.337 0.808 0.184 1.81610 3.078 0.308 0.797 0.223 1.777. . . . . .
12 12 Slide
Slide
Example: Granite Rock Co.
Control Limits for an x Chart: Process Meanand Standard Deviation Known
The weight of bags of cement filled by Granite’s packaging process is normally distributed with a mean of 50 pounds and a standard deviation of 1.5 pounds.
What should be the control limits for samples of 9 bags?
13 13 Slide
Slide
Example: Granite Rock Co.
Control Limits for an x Chart: Process Meanand Standard Deviation Known
= 50, = 1.5, n = 9
UCL = 50 + 3(.5) = 51.5 LCL = 50 - 3(.5) = 48.5
x n 15
9 05. .
14 14 Slide
Slide
Example: Granite Rock Co.
Control Limits for x and R Charts: Process Meanand Standard Deviation Unknown
Suppose Granite does not know the true mean and standard deviation for its bag filling process. It wants to develop x and R charts based on forty samples of 9 bags each. The average of the sample means is 50.1 pounds and the average of the sample ranges is 3.25 pounds.
15 15 Slide
Slide
Example: Granite Rock Co.
Control Limits for x and R Charts: Process Meanand Standard Deviation Unknown
x = 50.1, R = 3.25, n = 9• R Chart
UCL = RD4 = 3.25(1.816) = 5.9
LCL = RD3 = 3.25(0.184) = 0.6• x Chart
UCL = x + A2R = 50.1 + .337(3.25) = 51.2
LCL = x - A2R = 50.1 - .337(3.25) = 49.0
=
=
_
_
_
_
=
_
16 16 Slide
Slide
Control Limits for a p Chart
where:
assuming: np > 5 n(1-p) > 5
UCL = p p 3
LCL = p p 3
pp p
n
( )1
17 17 Slide
Slide
Control Limits for an np Chart
assuming: np > 5 n(1-p) > 5
Note: If computed LCL is negative, set LCL = 0
UCL = np np p 3 1( )
LCL = np np p 3 1( )
18 18 Slide
Slide
Acceptance Sampling
Acceptance sampling is a statistical method that enables us to base the accept-reject decision on the inspection of a sample of items from the lot.
Acceptance sampling has advantages over 100% inspection including: less expensive, less product damage, fewer people involved, . . . and more.
19 19 Slide
Slide
Acceptance Sampling Procedure
Lot received
Sample selected
Sampled itemsinspected for quality
Results compared withspecified quality characteristics
Accept the lot Reject the lot
Send to productionor customer
Decide on dispositionof the lot
Quality is not satisfactory
Quality issatisfactory
20 20 Slide
Slide
Acceptance Sampling
Acceptance sampling is based on hypothesis-testing methodology.
The hypothesis are: H0: Good-quality lot
Ha: Poor-quality lot
21 21 Slide
Slide
The Outcomes of Acceptance Sampling
Type I and Type II Errors State of the Lot
H0 True Ha True
Decision Good-Quality Lot Poor-Quality Lot
Accept H0 Correct Type II Error
Accept the Lot Decision Consumer’s Risk
Reject H0 Type I Error Correct
Reject the Lot Producer’s Risk Decision
22 22 Slide
Slide
Probability of Accepting a Lot
Binomial Probability Function for Acceptance Sampling
where:n = sample sizep = proportion of defective items in lotx = number of defective items in sample
f(x) = probability of x defective items in sample
f xn
x n xp px n x( )
!!( )!
( )( )
1
23 23 Slide
Slide
Example: Acceptance Sampling
An inspector takes a sample of 20 items from a lot.
Her policy is to accept a lot if no more than 2 defective
items are found in the sample.Assuming that 5 percent of a lot is defective, what is
the probability that she will accept a lot? Reject a lot?
n = 20, c = 2, and p = .05 P(Accept Lot) = f(0) + f(1) + f(2)
= .3585 + .3774 + .1887
= .9246 P(Reject Lot) = 1 - .9246 = .0754
24 24 Slide
Slide
Example: Acceptance Sampling
Using the Tables of Binomial Probabilities
pn x .05 .10 .15 .20 .25 .30 .35 .40 .45 .5020 0 .3585 .1216 .0388 .0115 .0032 .0008 .0002 .0000 .0000 .0000
1 .3774 .2702 .1368 .0576 .0211 .0068 .0020 .0005 .0001 .00002 .1887 .2852 .2293 .1369 .0669 .0278 .0100 .0031 .0008 .00023 .0596 .1901 .2428 .2054 .1339 .0716 .0323 .0123 .0040 .00114 .0133 .0898 .1821 .2182 .1897 .1304 .0738 .0350 .0139 .00465 .0022 .0319 .1028 .1746 .2023 .1789 .1272 .0746 .0365 .01486 .0003 .0089 .0454 .1091 .1686 .1916 .1712 .1244 .0746 .03707 .0000 .0020 .0160 .0545 .1124 .1643 .1844 .1659 .1221 .07398 .0000 .0004 .0046 .0222 .0609 .1144 .1614 .1797 .1623 .12019 .0000 .0001 .0011 .0074 .0271 .0654 .1158 .1597 .1771 .1602
25 25 Slide
Slide
Operating Characteristic Curve
.10.10
.20.20
.30.30
.40.40
.50.50
.60.60
.70.70
.80.80
.90.90
Pro
bab
ilit
y o
f A
ccep
tin
g t
he L
ot
Pro
bab
ilit
y o
f A
ccep
tin
g t
he L
ot
0 5 10 15 20 25 0 5 10 15 20 25
1.001.00
Percent Defective in the Lotp0
p1
b
(1 - a)
an = 15, c = 0
p0 = .03, p1 = .15
a = .3667, b = .0874
26 26 Slide
Slide
Multiple Sampling Plans
A multiple sampling plan uses two or more stages of sampling.
At each stage the decision possibilities are:• stop sampling and accept the lot,• stop sampling and reject the lot, or• continue sampling.
Multiple sampling plans often result in a smaller total sample size than single-sample plans with the same Type I error and Type II error probabilities.
27 27 Slide
Slide
A Two-Stage Acceptance Sampling Plan
Inspect n1 items
Find x1 defective items in this sample
Is x1 < c1 ?
Is x1 > c2 ?
Inspect n2 additional items
Acceptthe lot
Rejectthe lot
Is x1 + x2 < c3 ?
Find x2 defective items in this sample
Yes
YesNo
No
NoYes