8” SUBMERSIBLEELECTRIC PUMPS
Z855 – Z875Z895 – Z8125 SERIES
EDIT
ION
03-
2006
50 Hz
INDEX
Z8 Series Specifications............................................................................ 3Table of Materials .................................................................................... 4Hydraulic Performance Range, Z8 Series 50 Hz ....................................... 5Pump Cross-Section and List of Main Components .................................. 26L6C Series Motors ................................................................................... 27MC8 Series Motors.................................................................................. 31MC10 Series Motors................................................................................ 33AISI 316 F6 Series Motors ....................................................................... 35FW8 Series Motors .................................................................................. 37FW10 Series Motors ................................................................................ 39Accessories.............................................................................................. 41Technical Appendix.................................................................................. 61
3
8”SubmersibleElectricPumps
Z855Z875Z895Z8125Series
3
MARKET SECTORSAGRICULTURAL, INDUSTRIAL
APPLICATIONS
• Water supply from deep wells.• Pressure boosting and water distribution in civil and
industrial systems.• Supply of surge tanks and reservoirs.• Firefighting and washing systems.• Water level control.• Irrigation.• Mining.
SPECIFICATIONSPUMP
• Delivery: up to 180 m3/h.• Head: up to 550 m.• Maximum pump overall diameter
(2 cable covers included): 198 mmfor all versions.
• Maximum electric pump immersiondepth:250 m with L6C motors,40 m with MC8 and MC10 motors,standard configuration (with lipseal); version with mechanical sealavailable on request (max.immersion depth 350 m).
• Maximum permissible quantity ofsuspended sand: 100 g/m3.
• Standard delivery outlet:Rp 5” for all versions.
• Motor power: from 5.5 to 150 kW
MOTOR
• L6C motor: three-phase water-filledasynchronous motors withhermetically sealed stator
• MC8 and MC10 rewindable three-phase asynchronous motors withwater-filled winding.
• Three-phase version:L6C: from 3 to 37 kW 380-415V, 50HzMC8: from 30 to 92 kW 380-415V,50HzMC10: from 92 to 150 kW 380-415V,50Hz
• Maximum supply voltage variations: L6C 400V ±10%,MC8, MC10 400V +6% -10%.
• PVC windings for MC8 and MC10motors.
• Horizontal operation:L6C up to 37 kW provided that theassociated pump can apply an axialthrust of at least 250 N on theentire operating field.
MC8 and MC10 available on requestfor all versions
• Maximum number of starts perhour: 25 (L6C), 15 (MC8) and 10(MC10).
• Maximum temperature of water incontact with motor: 35°C (L6C),25°C (MC8 and MC10).
CONSTRUCTIONFEATURESPUMP
• Robust and lightweight, easy tomaintain and corrosion resistant innon-aggressive environments.– Impellers and diffusers
made of stainless steel.– Delivery casing made of
stainless steel.– Non-return valve made of
stainless steel, withintegrated spring.
– Suction support made ofstainless steel.
– Shaft made of stainlesssteel.
• The guide bearings and wear ringsensure high resistance to wear andguarantee the constant andlong-lasting performance ofthe hydraulic characteristics.
• Coupling and flange mountingdimensions meet NEMA standards.
• ZR8 version in DUPLEXstainless steel is also available.
OPTIONAL FEATURESMOTOR
• Different voltages and frequencies.• High temperature versions.• MC8 and MC10 for horizontal
installation.
ACCESSORIES• Coupling flange.• Panels.• Cables.
4
TABLE OF MATERIALS Z8
IDENTIFICATION CODESZ R 8 9 5 1 0 / 3 A – MC8
Motor code
Reduction type
Number of reduced stages
Number of stages
Flow rate in m3/h
Type of pump (R = DUPLEX version)
Blank = 50 Hz6 = 60 Hz
MATERIAL
EUROPE USA
Stainless steel EN 10213-4-GX5CrNi19-10 (1.4308) A744-CF 8Stainless steel EN 10213-4-GX5CrNi19-10 (1.4308) A744-CF 8NBR 90Stainless steel EN 10088-1-X5CrNiMo17-12-2 (1.4401) AISI 316Stainless steel EN 10213-4-GX5CrNi19-10 (1.4308) A744-CF 8NBR 70Stainless steel EN 10213-4-GX5CrNi19-10 (1.4308) A744-CF 8Duplex stainless steel EN 10088-1-X2CrNiMoN22-5-3 (1.4462) A276/A790-S31803POM (DELRIN ®)Stainless steel EN 10213-4-GX5CrNi19-10 (1.4308) A744-CF 8Stainless steel DIN 17440-X6CrNiMoTi17-12-2 (1.4571) AISI 316TiStainless steel EN 10088-1-X17CrNi16-2 (1.4057) AISI 431Stainless steel EN 10088-1-X17CrNi16-2 (1.4057) AISI 431EPDM + LOXAMID ®
PTFE + 25% carbonStainless steel ISO 3506-1/2 A4-70 AISI 316Stainless steel EN 10088-1-X5CrNi18-10 (1.4301) AISI 304
z8-2p50_c_tm
DESIGNATION
Delivery head / Valve CasingValveValve seatValve springDiffuser / BowlDiffuser O-RingImpellerTaperlockWear ringLower support / Suction CasingSuction strainerPump shaftCouplingBearing bushThrust BearingScrew, stud, nutCable protection
COMPONENT
TABLE OF MATERIALS ZR8MATERIAL
EUROPE USA
Duplex stainless steel EN 10213-4-GX2CrNiMoCuN25-6-3-3 (1.4517)Duplex stainless steel EN 10213-4-GX2CrNiMoCuN25-6-3-3 (1.4517)NBR 90Hastelloy C4 DIN17744-NiMo16Cr16Ti (2.4610) N06455Duplex stainless steel EN 10213-4-GX2CrNiMoCuN25-6-3-3 (1.4517)NBR 70Duplex stainless steel EN 10213-4-GX2CrNiMoCuN25-6-3-3 (1.4517)Duplex stainless steel EN 10088-1-X2CrNiMoN22-5-3 (1.4462) A276/A790-S31803POM (DELRIN ®)Duplex stainless steel EN 10213-4-GX2CrNiMoCuN25-6-3-3 (1.4517)Stainless steel EN 10088-1X1NiCrMoCu25-20-5 (1.4539) AISI 904LDuplex stainless steel EN 10088-1-X2CrNiMoN22-5-3 (1.4462) A276/A790-S31803Duplex stainless steel EN 10088-1-X2CrNiMoN22-5-3 (1.4462) A276/A790-S31803EPDM + LOXAMID ®
PTFE + 25% carbonDuplex stainless steel EN 10088-1-X2CrNiMoN22-5-3 (1.4462) A276/A790-S31803Stainless steel EN 10088-1X1NiCrMoCu25-20-5 (1.4539) AISI 904L
zr8-2p50_a_tm
COMPONENT DESIGNATION
Delivery head / Valve CasingValveValve seatValve springDiffuser / BowlDiffuser O-RingImpellerTaperlockWear ringLower support / Suction CasingSuction strainerPump shaftCouplingBearing bushThrust BearingScrew, stud, nutCable protection
EXAMPLE: ZR8 9510/3A - MC88” electric pump, 50 Hz, made of DUPLEX, flow rate 95 m3/h, 10 stages including 3 reduced ones, coupled to an 8” MC8 motor.
5
Z8 SERIESOPERATING CHARACTERISTICS AT 50 Hz
6
Z855 SERIES, 1 TO 7 STAGESOPERATING CHARACTERISTICS AT 50 Hz
DIMENSIONS AND WEIGHTS
1) Max electric-pump diameter with 2 motor cables included.In case of 1 motor cable C = 198 mm with L6C motor.
2) T min valid only for max flow speed of 4,2 m/s.For higher speeds please contact our sales network.
3) Without cables.4) For pumps without non-return valve, reduce dimension A by 110 mm, and reduce weight by 4 kg.
PUMP RATED l/min 0 167 500 833 1217 1333
TYPE POWER m3/h 0 10 30 50 73 80
kW
Z855 01 5,5 28,7 28 27 23 14 10,2 Z855 02/2A 7,5 45,7 44,4 43 35 14,9 Z855 02/1A 7,5 51,3 49,9 48 40 20,5 Z855 02 9,3 57 55,6 53 45 27 19,7 Z855 03/2A 11 74,2 72,1 69 57 27,7 Z855 03 15 86,1 83,9 80 69 41 30,7 Z855 04/2A 15 102,7 99,9 96 79 41 Z855 04 18,5 114,6 111,7 107 91 55 40,7 Z855 05/3A 18,5 125,6 122,2 117 97 49 Z855 05/2A 22 132,3 128,8 124 104 56,7 Z855 05 22 143,5 139,8 134 114 68 50,5 Z855 06/2A 30 160,7 156,6 150 127 70,9 Z855 06 30 172 167,6 160 137 83 61,3 Z855 07/2A 30 188,6 183,6 176 148 82,3 Z855 07 30 199,7 194,5 186 158 93 68,8
z855-2p50_a_th
H = TOTAL HEAD METRES COLUMN OF WATER
Q = DELIVERY
ELECTRO- ELECTRO-
PUMP PUMP
TYPE WEIGHT
A(4)
C(1) M Tmin
(2)kg
(3)
Z855 01-L6C 1191 200 140 1631 70 Z855 02/2A-L6C 1355 200 140 1660 81 Z855 02/1A-L6C 1355 200 140 1660 81 Z855 02-L6C 1380 200 140 1685 84 Z855 03/2A-L6C 1560 200 140 1730 97 Z855 03-L6C 1615 200 140 1785 103 Z855 04/2A-L6C 1750 200 140 1785 112 Z855 04-L6C 1825 200 140 1860 119 Z855 05/3A-L6C 1960 200 140 1860 128 Z855 05/2A-L6C 2020 200 140 1920 134 Z855 05-L6C 2020 200 140 1920 134 Z855 06/2A-L6C 2285 200 140 2050 155 Z855 06-L6C 2285 200 140 2050 155 Z855 07/2A-L6C 2420 200 140 2050 164 Z855 07-L6C 2420 200 140 2050 164
z855-2p50_a_td
DIMENSIONS (mm)
7
Z855 SERIES, 1 TO 7 STAGESOPERATING CHARACTERISTICS AT 50 Hz
The flow resistance of the non-return valve has been considered.These performances are valid for liquids with density ρ = 1,0 kg/dm3 and kinematic viscosity υ = 1 mm2/sec.
8
Z855 SERIES, 8 TO 19 STAGESOPERATING CHARACTERISTICS AT 50 Hz
DIMENSIONS AND WEIGHTS
1) Max electric-pump diameter with 2 motor cables included.In case of 1 motor cable C = 198 mm with L6C motor.
C = 201,5 mm with MC8 motor.2) T min valid only for max flow speed of 4,2 m/s.
For higher speeds please contact our sales network.3) Without cables.4) For pumps without non-return valve, reduce dimension A by 110 mm, and reduce weight by 4 kg.
PUMP RATED l/min 0 167 500 833 1217 1333
TYPE POWER m3/h 0 10 30 50 73 80
kW
Z855 08/2A 37 217 211,5 202,8 171 96,1 Z855 08 37 228,3 222,5 212,7 181 107,3 79,4 Z855 09/2A 37 244,8 238,3 227,8 191,2 106,8 Z855 09 44 260,6 254,2 244,3 210,6 128,5 96,9 Z855 10/2A 44 277,5 270,5 260,1 221,5 128,4 Z855 10 44 288,8 281,7 270,3 231,9 140,2 105,2 Z855 11/2A 52 305,6 298 286,6 244,8 143,2 Z855 11 52 316,9 309,2 296,8 255,4 155,4 116,9 Z855 12 55 346,6 338,3 324,8 279,8 170,5 128,5 Z855 13 59 375,3 366,1 351,3 302,3 183,7 138,2 Z855 14 66 404,5 394,7 379,1 326,6 198,9 149,9 Z855 15 66 432,8 422,2 404,9 348 210,9 158,4 Z855 16 75 461,6 450,3 432,1 372,2 226,5 170,5 Z855 17 92 491,8 479,8 461,2 398,8 244,6 185 Z855 18 92 520 507,3 487,4 420,8 257 194 Z855 19 92 551,2 538 517 446,3 273,5 206,9
z855a-2p50_a_th
H = TOTAL HEAD METRES COLUMN OF WATER
Q = DELIVERY
ELECTRO- ELECTRO-
PUMP PUMP
TYPE WEIGHT
A(4)
C(1) M Tmin
(2)kg
(3)
Z855 08/2A-L6C 2685 200 140 2180 186 Z855 08-L6C 2685 200 140 2180 186 Z855 09/2A-L6C 2820 200 140 2180 194 Z855 09-MC8 2835 203,3 192 2195 276 Z855 10/2A-MC8 2970 203,3 192 2195 284 Z855 10-MC8 2970 203,3 192 2195 284 Z855 11/2A-MC8 3195 203,3 192 2285 313 Z855 11-MC8 3195 203,3 192 2285 313 Z855 12-MC8 3370 203,3 192 2325 328 Z855 13-MC8 3555 203,3 192 2375 347 Z855 14-MC8 3780 203,3 192 2465 374 Z855 15-MC8 3915 203,3 192 2465 382 Z855 16-MC8 4140 203,3 192 2555 408 Z855 17-MC8 4475 203,3 192 2755 455 Z855 18-MC8 4610 203,3 192 2755 463 Z855 19-MC8 4745 203,3 192 2755 472
z855a-2p50_a_td
DIMENSIONS (mm)
9
Z855 SERIES, 8 TO 19 STAGESOPERATING CHARACTERISTICS AT 50 Hz
The flow resistance of the non-return valve has been considered.These performances are valid for liquids with density ρ = 1,0 kg/dm3 and kinematic viscosity υ = 1 mm2/sec.
10
Z875 SERIES, 1 TO 6 STAGESOPERATING CHARACTERISTICS AT 50 Hz
DIMENSIONS AND WEIGHTS
1) Max electric-pump diameter with 2 motor cables included.In case of 1 motor cable C = 198 mm with L6C motor.
2) T min valid only for max flow speed of 4.2 m/s.For higher speeds please contact our sales network.
3) Without cables.4) For pumps without non-return valve, reduce dimension A by 110 mm, and reduce weight by 4 kg.
PUMP RATED l/min 0 250 700 1167 1700 1833
TYPE POWER m3/h 0 15 42 70 102 110
kW
Z875 01 5,5 28,9 26,9 24,2 20,1 11,8 9,2Z875 02/2A 7,5 44,1 42,1 38,2 29,3 11,3Z875 02/1A 9,3 50,8 48 43,3 34,7 17,6Z875 02 11 57,9 54,1 48,7 40,5 23,9 18,6Z875 03/3A 11 66,1 63,1 57,2 43,7 16,9Z875 03/2A 15 73,5 69,7 63,3 50,4 24Z875 03/1A 15 80,1 75,3 68 55,3 29,8Z875 03 18,5 87,5 81,7 73,9 61,8 37 29,1Z875 04/2A 18,5 102,3 96,5 87,4 70,3 35,6Z875 04 22 116,5 108,8 98,1 81,8 48,8 38,1Z875 05/3A 22 124,7 117,9 106,7 85,2 41,4Z875 05/2A 30 132,1 124,4 112,9 92,1 49,3Z875 05 30 145,3 135,8 122,5 102,3 61 47,7Z875 06/2A 30 160 150,4 135,9 110,6 59,7Z875 06/1A 30 166,5 156 140,6 115,5 65,8Z875 06 37 174,2 162,8 147,1 122,7 73,1 57,2
z875-2p50_a_th
H = TOTAL HEAD METRES COLUMN OF WATER
Q = DELIVERY
ELECTRO- ELECTRO-
PUMP PUMP
TYPE WEIGHT
A(4)
C(1) M Tmin
(2)kg
(3)
Z875 01-L6C 1208 200 140 1631 71Z875 02/2A-L6C 1389 200 140 1660 82Z875 02/1A-L6C 1414 200 140 1685 85Z875 02-L6C 1459 200 140 1730 89Z875 03/3A-L6C 1611 200 140 1730 99Z875 03/2A-L6C 1666 200 140 1785 105Z875 03/1A-L6C 1666 200 140 1785 105Z875 03-L6C 1741 200 140 1860 112Z875 04/2A-L6C 1893 200 140 1860 121Z875 04-L6C 1953 200 140 1920 127Z875 05/3A-L6C 2105 200 140 1920 137Z875 05/2A-L6C 2235 200 140 2050 149Z875 05-L6C 2235 200 140 2050
2050149
Z875 06/2A-L6C 2387 200 140 159Z875 06/1A-L6C 2387 200 140 2050 159Z875 06-L6C 2517 200 140 2180 172
z875-2p50_a_td
DIMENSIONS (mm)
11
Z875 SERIES, 1 TO 6 STAGESOPERATING CHARACTERISTICS AT 50 Hz
The flow resistance of the non-return valve has been considered.These performances are valid for liquids with density ρ = 1,0 Kg/dm3 and kinematic viscosity υ = 1 mm2/sec.
12
Z875 SERIES, 7 TO 18 STAGESOPERATING CHARACTERISTICS AT 50 Hz
DIMENSIONS AND WEIGHTS
1) Max electric-pump diameter with 2 motor cables included.In case of 1 motor cable C = 198 mm with L6C motor.
C = 201,5 mm with MC8 motor.2) T min valid only for max flow speed of 4.2 m/s.
For higher speeds please contact our sales network.3) Without cables.4) For pumps without non-return valve, reduce dimension A by 110 mm, and reduce weight by 4 kg.
PUMP RATED l/min 0 250 700 1167 1700 1833
TYPE POWER m3/h 0 15 42 70 102 110
kW
Z875 07/2A 37 189 177,5 160,4 131 71,8Z875 07 37 202 188,7 169,8 140,8 82,7 64,2Z875 08/3A 37 210,1 197,7 178,3 143,9 76,7Z875 08/2A 44 221,5 208 188,9 156,2 88,7Z875 08 44 234,9 219,6 198,8 166,5 100,6 79,3Z875 09/2A 44 249,9 234,6 212,4 175,1 99,1Z875 09 52 263,6 246,4 223 187,2 113,3 89,3Z875 10/2A 52 278,5 261,3 236,7 196 112,1Z875 10 52 291,8 272,7 246,5 206,5 124,1 97,5Z875 11/2A 55 308,6 298,4 262,1 217,4 125,1Z875 11 59 322,3 301,3 272,5 228,5 138 108,7Z875 12 66 352,1 329,1 297,9 249,9 151,1 119,2Z875 13 75 381,2 356,4 322,6 271 164,3 129,7Z875 14 75 409,5 382,8 346,2 290,3 175,1 137,9Z875 15 92 440,2 411,5 373 313,8 190,6 150,7Z875 16 92 471,8 441,2 399,6 336 204,6 162,1Z875 17 92 500,3 467,8 423,3 355,4 215,7 170,4Z875 18 92 530,1 495,7 449,6 378,8 231,2 183,3
z875a-2p50_a_th
H = TOTAL HEAD METRES COLUMN OF WATER
Q = DELIVERY
ELECTRO- ELECTRO-
PUMP PUMP
TYPE WEIGHT
A(4)
C(1) M Tmin
(2)kg
(3)
Z875 07/2A-L6C 2669 200 140 2180 181Z875 07-L6C 2669 200 140 2180 181Z875 08/3A-L6C 2821 200 140 2180 190Z875 08/2A-MC8 2836 203,3 192 2195 271Z875 08-MC8 2836 203,3 192 2195 271Z875 09/2A-MC8 2988 203,3 192 2195 281Z875 09-MC8 3078 203,3 192 2285 301Z875 10/2A-MC8 3230 203,3 192 2285 310Z875 10-MC8 3230 203,3 192 2285 310Z875 11/2A-MC8 3422 203,3 192 2325 325Z875 11-MC8 3472 203,3 192 2375 336Z875 12-MC8 3714 203,3 192 2465 363Z875 13-MC8 3956 203,3 192 2555 389Z875 14-MC8 4108 203,3 192 2555 399Z875 15-MC8 4460 203,3 192 2755 446Z875 16-MC8 4612 203,3 192 2755 455Z875 17-MC8 4764 203,3 192 2755 464Z875 18-MC8 4916 203,3 192 2755 474
z875a-2p50_a_td
DIMENSIONS (mm)
13
Z875 SERIES, 7 TO 18 STAGESOPERATING CHARACTERISTICS AT 50 Hz
The flow resistance of the non-return valve has been considered.These performances are valid for liquids with density ρ = 1,0 Kg/dm3 and kinematic viscosity υ = 1 mm2/sec.
14
Z895 SERIES, 1 TO 6 STAGESOPERATING CHARACTERISTICS AT 50 Hz
DIMENSIONS AND WEIGHTS
1) Max electric-pump diameter with 2 motor cables included.In case of 1 motor cable C = 198 mm with L6C motor.
C = 201,5 mm with MC8 motor.2) T min valid only for max flow speed of 4,2 m/s.
For higher speeds please contact our sales network.3) Without cables.4) For pumps without non-return valve, reduce dimension A by 110 mm, and reduce weight by 4 kg.
PUMP RATED l/min 0 367 1000 1500 2150 2300
TYPE POWER m3/h 0 22 60 90 129 138
kW
Z895 01 7,5 28,5 27,7 25,3 21,6 12,3 9,8Z895 02/2B 11 38,7 38,3 35,2 27,5Z895 02/2A 15 47,7 46,6 44 36,4 17,8Z895 02 15 57 55,4 50,7 43,2 24,6 19,5Z895 03/2B 18,5 67,2 66,1 60,8 49,4Z895 03/1A 22 81,1 79 73 61,8 34Z895 03 30 86 83,8 77,3 66,4 39 30,4Z895 04/2B 30 96 94,1 86,7 71,8Z895 04/2A 30 104,5 102 94,7 79,7 42,5Z895 04 30 113,8 110,7 101,4 86,5 49,3 39,2Z895 05/3A 37 128 125 116,4 97,5 50,8Z895 05 37 141,9 138 126,4 107,5 60,9 48,7Z895 06/3A 44 158,4 154,8 144,6 122,4 67,1Z895 06 44 172,6 168,1 154,9 132,8 77,7 60,5
z895-2p50_a_th
H = TOTAL HEAD METRES COLUMN OF WATER
Q = DELIVERY
ELECTRO- ELECTRO-
PUMP PUMP
TYPE WEIGHT
A(4)
C(1) M Tmin
(2)kg
(3)
Z895 01-L6C 1237 200 140 1660 73Z895 02/2B-L6C 1459 200 140 1730 89Z895 02/2A-L6C 1514 200 140 1785 96Z895 02-L6C 1514 200 140 1785 96Z895 03/2B-L6C 1741 200 140 1860 112Z895 03/1A-L6C 1801 200 140 1920 118Z895 03-L6C 1931 200 140 2050 131Z895 04/2B-L6C 2083 200 140 2050 140Z895 04/2A-L6C 2083 200 140 2050 140Z895 04-L6C 2083 200 140 2050 140Z895 05/3A-L6C 2365 200 140 2180 162Z895 05-L6C 2365 200 140 2180 162Z895 06/3A-MC8 2532 203,3 192 2195 254Z895 06-MC8 2532 203,3 192 2195 254
z895-2p50_a_td
DIMENSIONS (mm)
15
Z895 SERIES, 1 TO 6 STAGESOPERATING CHARACTERISTICS AT 50 Hz
The flow resistance of the ∆Hv non-return valve has not been considered.∆Hv = 0,0000533*Q2 Flow resistance = 0,2 / 0,45 / 0,75 m at 60 / 90 / 120 m3/hThese performances are valid for liquids with density ρ = 1,0 Kg/dm3 and kinematic viscosity υ = 1 mm2/sec.
16
Z895 SERIES, 7 TO 18 STAGESOPERATING CHARACTERISTICS AT 50 Hz
DIMENSIONS AND WEIGHTS
1) Max electric-pump diameter with 2 motor cables included.In case of 1 motor cable C = 201,5 mm with MC8 motor.
C = 236 mm with MC10 motor.2) T min valid only for max flow speed of 4,2 m/s.
For higher speeds please contact our sales network.3) Without cables.4) For pumps without non-return valve, reduce dimension A by 110 mm, and reduce weight by 4 kg.
PUMP RATED l/min 0 367 1000 1500 2150 2300
TYPE POWER m3/h 0 22 60 90 129 138
kW
Z895 07/3A 52 186,5 182,1 169,6 144 79,8Z895 07 55 201,5 196,4 181,3 156,2 92,4 72,4Z895 08/3A 59 215,7 210,6 196 166,7 93,3Z895 08 59 229,9 223,9 206,3 177,2 104 81,1Z895 09/3A 66 244,4 238,6 221,9 188,9 106,2Z895 09 75 258,9 252,4 233 200,8 119 93,2Z895 10/3A 75 272,9 266,3 247,3 210,9 119,3Z895 10 75 287 279,6 257,6 221,5 130 101,4Z895 11 92 316,3 308,2 284,6 245,2 145 113,4Z895 12 92 346,3 337,6 311,5 268,1 158,8 124,4Z895 13 110 374,9 365,6 338,1 291,9 174 137,5Z895 14 110 403,1 393 363 312,8 185,4 145,2Z895 15 129 434,2 423,5 391,4 337,7 201,8 159Z895 16 129 462,6 451 416,2 358,6 213,2 169Z895 17 129 490,9 478,4 440,9 379,4 224,2 175,5Z895 18 150 520,2 507,1 468,5 404,2 241 189,3
z895a-2p50_a_th
H = TOTAL HEAD METRES COLUMN OF WATER
Q = DELIVERY
ELECTRO- ELECTRO-
PUMP PUMP
TYPE WEIGHT
A(4)
C(1) M Tmin
(2)kg
(3)
Z895 07/3A-MC8 2774 203,3 192 2285 282Z895 07-MC8 2814 203,3 192 2325 288Z895 08/3A-MC8 3016 203,3 192 2375 308Z895 08-MC8 3016 203,3 192 2375 308Z895 09/3A-MC8 3258 203,3 192 2465 336Z895 09-MC8 3348 203,3 192 2555 353Z895 10/3A-MC8 3500 203,3 192 2555 362Z895 10-MC8 3500 203,3 192 2555 362Z895 11-MC8 3852 203,3 192 2755 409Z895 12-MC8 4004 203,3 192 2755 418Z895 13-MC10 4124 236 236 2702 538Z895 14-MC10 4276 236 236 2702 548Z895 15-MC10 4578 236 236 2852 604Z895 16-MC10 4730 236 236 2852 613Z895 17-MC10 4882 236 236 2852 622Z895 18-MC10 5164 236 236 2982 671
z895a-2p50_a_td
DIMENSIONS (mm)
1717
Z895 SERIES, 7 TO 18 STAGESOPERATING CHARACTERISTICS AT 50 Hz
The flow resistance of the ∆Hv non-return valve has not been considered.∆Hv = 0,0000533*Q2 Flow resistance = 0,2 / 0,45 / 0,75 m at 60 / 90 / 120 m3/hThese performances are valid for liquids with density ρ = 1,0 Kg/dm3 and kinematic viscosity υ = 1 mm2/sec.
18
Z8125 SERIES, 1 TO 6 STAGESOPERATING CHARACTERISTICS AT 50 Hz
DIMENSIONS AND WEIGHTS
1) Max electric-pump diameter with 2 motor cables included.In case of 1 motor cable C = 198 mm with L6C motor.
C = 201,5 mm with MC8 motor.2) T min valid only for max flow speed of 4,2 m/s.
For higher speeds please contact our sales network.3) Without cables.4) For pumps without non-return valve, reduce dimension A by 110 mm, and reduce weight by 4 kg.
PUMP RATED l/min 0 500 1333 2083 2800 3000
TYPE POWER m3/h 0 30 80 125 168 180
kW
Z8125 01 7,5 27,1 24,7 21 17,1 9,4 6,9Z8125 02/2B 11 41,9 38,8 31,8 22,3Z8125 02/2A 15 48,3 44,6 37,5 28,9 13Z8125 02 15 54,3 49,5 42 34,1 18,8 13,7Z8125 03/3A 18,5 71,9 66,2 55,5 42,6 19,3Z8125 03 22 81,7 74,6 63,4 51,5 28,7 20,7Z8125 04/2B 30 97 89,2 74,8 57,5Z8125 04/2A 30 102,6 94,1 79,5 63,1 32,9Z8125 04 30 108,5 99 84,1 68,3 37,8 27,5Z8125 05/3A 37 126,4 116 97,9 77,1 39,3Z8125 05 37 135,2 123,4 104,7 84,8 46,6 34,2Z8125 06/3A 44 156,4 143,5 121,7 97,1 50,2Z8125 06 44 165,5 151,1 128,8 105 60 41,9
z8125-2p50_a_th
H = TOTAL HEAD METRES COLUMN OF WATER
Q = DELIVERY
ELECTRO- ELECTRO-
PUMP PUMP
TYPE WEIGHT
A(4)
C(1) M Tmin
(2)kg
(3)
Z8125 01-L6C 1237 200 140 1660 73Z8125 02/2B-L6C 1459 200 140 1730 89Z8125 02/2A-L6C 1514 200 140 1785 96Z8125 02-L6C 1514 200 140 1785 96Z8125 03/3A-L6C 1741 200 140 1860 112Z8125 03-L6C 1801 200 140 1920 118Z8125 04/2B-L6C 2083 200 140 2050 140Z8125 04/2A-L6C 2083 200 140 2050 140Z8125 04-L6C 2083 200 140 2050 140Z8125 05/3A-L6C 2365 200 140 2180 162Z8125 05-L6C 2365 200 140 2180 162Z8125 06/3A-MC8 2532 203,3 192 2195 254Z8125 06-MC8 2532 203,3 192 2195 254
z8125-2p50_a_td
DIMENSIONS (mm)
19
Z8125 SERIES, 1 TO 6 STAGESOPERATING CHARACTERISTICS AT 50 Hz
The flow resistance of the ∆Hv non-return valve has not been considered.∆Hv = 0,0000533*Q2 Flow resistance = 0,35 / 0,75 / 1,35 m at 80 / 120 / 160 m3/hThese performances are valid for liquids with density ρ = 1,0 Kg/dm3 and kinematic viscosity υ = 1 mm2/sec.
20
Z8125 SERIES, 7 TO 18 STAGESOPERATING CHARACTERISTICS AT 50 Hz
DIMENSIONS AND WEIGHTS
1) Max electric-pump diameter with 2 motor cables included.In case of 1 motor cable C = 201,5 mm with MC8 motor.
C = 236 mm with MC10 motor.2) T min valid only for max flow speed of 4.2 m/s.
For higher speeds please contact our sales network.3) Without cables.4) For pumps without non-return valve, reduce dimension A by 110 mm, and reduce weight by 4 kg.
PUMP RATED l/min 0 500 1333 2083 2800 3000
TYPE POWER m3/h 0 30 80 125 168 180
kW
Z8125 07/3A 52 183,3 168 142,6 114,3 60,2Z8125 07 52 192,3 175,6 149,8 122,5 69,8 48,8Z8125 08/3A 55 210,9 193,2 164,1 131,8 70,3Z8125 08 59 220,5 201,3 171,8 140,4 80,3 55,9Z8125 09/3A 66 239 218,9 186 149,8 80,6Z8125 09 66 248,1 226,5 193,2 157,8 90,3 62,9Z8125 10/3A 75 266,2 243,7 207,3 167,4 90,7Z8125 10 75 275,3 251,4 214,6 175,4 100,3 69,9Z8125 11 92 304,2 277,8 237,4 194,4 112,2 76,8Z8125 12 92 332,7 303,9 259,6 212,5 123 84,5Z8125 13 110 361,2 329,9 282,3 231,6 134,9 93,1Z8125 14 110 387,9 354,2 302,8 248 143,5 98,5Z8125 15 110 414,3 378,3 323 264,2 151,9 104Z8125 16 129 444,5 406 347 284,4 165,3 113,9Z8125 17 129 470,9 430,1 367,3 300,6 173,7 119,5Z8125 18 150 500,4 457,1 391 320,8 186,8 128,9
z8125a-2p50_a_th
H = TOTAL HEAD METRES COLUMN OF WATER
Q = DELIVERY
ELECTRO- ELECTRO-
PUMP PUMP
TYPE WEIGHT
A(4)
C(1) M Tmin
(2)kg
(3)
Z8125 07/3A-MC8 2774 203,3 192 2285 282Z8125 07-MC8 2774 203,3 192 2285 282Z8125 08/3A-MC8 2966 203,3 192 2325 297Z8125 08-MC8 3016 203,3 192 2375 308Z8125 09/3A-MC8 3250 203,3 192 2465 336Z8125 09-MC8 3250 203,3 192 2465 336Z8125 10/3A-MC8 3500 203,3 192 2555 362Z8125 10-MC8 3500 203,3 192 2555 362Z8125 11-MC8 3852 203,3 192 2755 409Z8125 12-MC8 4004 203,3 192 2755 418Z8125 13-MC10 4124 236 236 2702 538Z8125 14-MC10 4276 236 236 2702 548Z8125 15-MC10 4428 236 236 2702 557Z8125 16-MC10 4730 236 236 2852 613Z8125 17-MC10 4882 236 236 2852 622Z8125 18-MC10 5164 236 236 2982 671
z8125a-2p50_a_td
DIMENSIONS (mm)
21
Z8125 SERIES, 7 TO 18 STAGESOPERATING CHARACTERISTICS AT 50 Hz
The flow resistance of the ∆Hv non-return valve has not been considered.∆Hv = 0,0000533*Q2 Flow resistance = 0,35 / 0,75 / 1,35 m at 80 / 120 / 160 m3/hThese performances are valid for liquids with density ρ = 1,0 Kg/dm3 and kinematic viscosity υ = 1 mm2/sec.
22
Z855 SERIESDIMENSIONS AND WEIGHTS
MOTOR COUPLING
1) Max pump diameter with 1 motor cable included.
2) U min valid only for max flow speed of 4.2 m/s.
For higher speeds please contact our sales network.
3) For pumps without non-return valve, reduce dimension L by 110 mm, and reduce weight by 4 kg.
MAX POWER
PUMP ABSORBED BY PUMP
TYPE at 2900 rpm kW L
(3) I Umin(2)
kg(3)
Z855 01 4,6 325 235 1000 26,6 Z855 02/2A 6,4 460 235 1000 35,2 Z855 02/1A 7,7 460 235 1000 35,2 Z855 02 9,0 460 235 1000 35,2 Z855 03/2A 10,8 595 235 1000 43,9 Z855 03 13,3 595 235 1000 43,9 Z855 04/2A 15,1 730 235 1000 52,5 Z855 04 17,6 730 235 1000 52,5 Z855 05/3A 18,3 865 235 1000 61,2 Z855 05/2A 20,8 865 235 1000 61,2 Z855 05 22,0 865 235 1000 61,2 Z855 06/2A 23,9 1000 235 1000 69,8 Z855 06 26,4 1000 235 1000 69,8 Z855 07/2A 28,3 1135 235 1000 78,5 Z855 07 30,8 1135 235 1000 78,5 Z855 08/2A 32,7 1270 235 1000 87,1 Z855 08 35,2 1270 235 1000 87,1 Z855 09/2A 37,1 1405 235 1000 95,8 Z855 09 39,6 1405 235 1000 95,1 Z855 10/2A 41,5 1540 235 1000 103,8 Z855 10 44,0 1540 235 1000 103,8 Z855 11/2A 45,9 1675 235 1000 112,4 Z855 11 48,4 1675 235 1000 112,4 Z855 12 52,8 1810 235 1000 121,1 Z855 13 57,2 1945 235 1000 129,7 Z855 14 61,6 2080 235 1000 138,4 Z855 15 66,0 2215 235 1000 147 Z855 16 70,4 2350 235 1000 155,7 Z855 17 74,8 2485 235 1000 164,3 Z855 18 79,2 2620 235 1000 173 Z855 19 83,6 2755 235 1000 181,6
z855p-2p50_a_td
DIMENSIONS (mm) WEIGHT
N k d z b EH7 R X
6" (NEMA) 182 111 13,5 4 17 76,16 73 248" (NEMA) 182 152,4 18 4 17 127 101,3 40
z8-mtcn-2p50_a_td
6" and 8" coupling according to NEMA standards
DIMENSIONS (mm)MOTOR
23
Z875 SERIESDIMENSIONS AND WEIGHTS
MOTOR COUPLING
1) Max pump diameter with 1 motor cable included.
2) U min valid only for max flow speed of 4.2 m/s.
For higher speeds please contact our sales network.
3) For pumps without non-return valve, reduce dimension L by 110 mm, and reduce weight by 4 kg.
kW L(3) I Umin
(2)kg
(3)
Z875 01 5,3 342 235 1000 26,9Z875 02/2A 7,6 494 235 1000 36,2Z875 02/1A 9,0 494 235 1000 36,2Z875 02 10,5 494 235 1000 36,2Z875 03/3A 11,3 646 235 1000 45,4Z875 03/2A 12,7 646 235 1000 45,4Z875 03/1A 14,2 646 235 1000 45,4Z875 03 15,6 646 235 1000 45,4Z875 04/2A 17,7 798 235 1000 54,6Z875 04 20,6 798 235 1000 54,6Z875 05/3A 21,5 950 235 1000 63,9Z875 05/2A 22,9 950 235 1000 63,9Z875 05 25,8 950 235 1000 63,9Z875 06/2A 28,0 1102 235 1000 73,1Z875 06/1A 29,5 1102 235 1000 73,1Z875 06 30,9 1102 235 1000 73,1Z875 07/2A 33,2 1254 235 1000 82,3Z875 07 36,1 1254 235 1000 82,3Z875 08/3A 36,9 1406 235 1000 91,5Z875 08/2A 38,3 1406 235 1000 90,9Z875 08 41,2 1406 235 1000 90,9Z875 09/2A 43,5 1558 235 1000 100,1Z875 9 46,4 1558 235 1000 100,1Z875 10/2A 48,6 1710 235 1000 109,4Z875 10 51,5 1710 235 1000 109,4Z875 11/2A 53,8 1862 235 1000 118,6Z875 11 56,7 1862 235 1000 118,6Z875 12 61,8 2014 235 1000 127,8Z875 13 67,0 2166 235 1000 137Z875 14 72,1 2318 235 1000 146,3Z875 15 77,3 2470 235 1000 155,5Z875 16 82,4 2622 235 1000 164,7Z875 17 87,6 2774 235 1000 174Z875 18 92,7 2926 256 1000 183,2
z875p-2p50_a_td
MAX POWER
PUMP ABSORBED BY PUMP
TYPE at 2900 rpm
DIMENSIONS (mm) WEIGHT
N k d z b E H7 R X6" (NEMA) 182 111 13,5 4 17 76,16 73 248" (NEMA) 182 152,4 18 4 17 127 101,3 40
10" 232 190,5 M16 4 21 127 101,3 84
z8a-mtcn-2p50_a_td
6" and 8" coupling according to NEMA standards
DIMENSIONS (mm)MOTOR
24
Z895 SERIESDIMENSIONS AND WEIGHTS
MOTOR COUPLING
1) Max pump diameter with 1 motor cable included.
2) U min valid only for max flow speed of 4.2 m/s.
For higher speeds please contact our sales network.
3) For pumps without non-return valve, reduce dimension L by 110 mm, and reduce weight by 4 kg.
kW L(3) I Umin
(2)kg
(3)
Z895 01 7,7 342 235 1000 26,9Z895 02/2B 10,0 494 235 1000 36,2Z895 02/2A 12,8 494 235 1000 36,2Z895 02 15,2 494 235 1000 36,2Z895 03/2B 17,4 646 235 1000 45,4Z895 03/1A 21,4 646 235 1000 45,4Z895 03 22,5 646 235 1000 45,4Z895 04/2B 24,6 798 235 1000 54,6Z895 04/2A 27,4 798 235 1000 54,6Z895 04 29,8 798 235 1000 54,6Z895 05/3A 33,7 950 235 1000 63,9Z895 05 37,2 950 235 1000 63,9Z895 06/3A 41,1 1102 235 1000 73,1Z895 06 44,6 1102 235 1000 73,1Z895 07/3A 48,6 1254 235 1000 81,7Z895 07 52,1 1254 235 1000 81,7Z895 08/3A 56,0 1406 235 1000 90,9Z895 08 59,5 1406 235 1000 90,9Z895 09/3A 63,5 1558 235 1000 100,1Z895 09 67,0 1558 235 1000 100,1Z895 10/3A 70,9 1710 235 1000 109,4Z895 10 74,4 1710 235 1000 109,4Z895 11 81,8 1862 235 1000 118,6Z895 12 89,3 2014 235 1000 127,8Z895 13 96,7 2166 256 1000 137Z895 14 104,2 2318 256 1000 146,3Z895 15 111,6 2470 256 1000 155,5Z895 16 119,0 2622 256 1000 164,7Z895 17 126,5 2774 256 1000 174Z895 18 133,9 2926 256 1000 183,2
z895p-2p50_a_td
MAX POWER
PUMP ABSORBED BY PUMP
TYPE at 2900 rpm DIMENSIONS (mm) WEIGHT
N k d z b E H7 R X6" (NEMA) 182 111 13,5 4 17 76,16 73 248" (NEMA) 182 152,4 18 4 17 127 101,3 40
10" 232 190,5 M16 4 21 127 101,3 84
z8a-mtcn-2p50_a_td
6" and 8" coupling according to NEMA standards
DIMENSIONS (mm)MOTOR
25
Z8125 SERIESDIMENSIONS AND WEIGHTS
MOTOR COUPLING
1) Max pump diameter with 1 motor cable included.
2) U min valid only for max flow speed of 4.2 m/s.
For higher speeds please contact our sales network.
3) For pumps without non-return valve, reduce dimension L by 110 mm, and reduce weight by 4 kg.
kW L(3) I Umin
(2)kg
(3)
Z8125 01 7,5 342 235 1000 26,9Z8125 02/2B 10,0 494 235 1000 36,2Z8125 02/2A 12,2 494 235 1000 36,2Z8125 02 14,8 494 235 1000 36,2Z8125 03/3A 18,1 646 235 1000 45,4Z8125 03 22,0 646 235 1000 45,4Z8125 04/2B 24,3 798 235 1000 54,6Z8125 04/2A 26,5 798 235 1000 54,6Z8125 04 29,0 798 235 1000 54,6Z8125 05/3A 32,5 950 235 1000 63,9Z8125 05 36,3 950 235 1000 63,9Z8125 06/3A 39,7 1102 235 1000 73,1Z8125 06 43,5 1102 235 1000 73,1Z8125 07/3A 47,0 1254 235 1000 81,7Z8125 07 50,8 1254 235 1000 81,7Z8125 08/3A 54,2 1406 235 1000 90,9Z8125 08 58,0 1406 235 1000 90,9Z8125 09/3A 61,5 1558 235 1000 100,1Z8125 09 65,3 1558 235 1000 100,1Z8125 10/3A 68,7 1710 235 1000 109,4Z8125 10 72,5 1710 235 1000 109,4Z8125 11 79,8 1862 235 1000 118,6Z8125 12 87,0 2014 235 1000 127,8Z8125 13 94,3 2166 256 1000 137Z8125 14 101,5 2318 256 1000 146,3Z8125 15 108,8 2470 256 1000 155,5Z8125 16 116,0 2622 256 1000 164,7Z8125 17 123,3 2774 256 1000 174Z8125 18 130,5 2926 256 1000 183,2
z8125p-2p50_a_td
MAX POWER
PUMP ABSORBED BY PUMP
TYPE at 2900 rpm
DIMENSIONS (mm) WEIGHT
N k d z b E H7 R X6" (NEMA) 182 111 13,5 4 17 76,16 73 248" (NEMA) 182 152,4 18 4 17 127 101,3 40
10" 232 190,5 M16 4 21 127 101,3 84
z8a-mtcn-2p50_a_td
6" and 8" coupling according to NEMA standards
DIMENSIONS (mm)MOTOR
26
Z8 SERIES PUMPSPUMP CROSS SECTION AND LIST OF COMPONENTS
1 Stage casingSuction casingDelivery casingValve bodyBearing bushImpellerWear ringShaftCouplingLocking sleeveThrust bearingWing valveValve seatValve springSuction strainerMotor cableCable guardO-ring10" Motor adapterClamping plate
234567891011121314151617181920
z8-2p50_a_tp
REF. N. DESCRIPTION
27
● Axial thrust:16000 N from 4 to 22 kW motors27000 N from 30 to 37 kW motors
● Extractable supply cablefitted with watertight connector.
● Versions:– Three-phase:
4 to 37 kW 380-415 V, 50 Hz● Motors with double cable outlet for
star/delta start can be supplied uponrequest.
● Can also operate in horizontalposition, provided that the associatedpump can apply an axial thrust of atleast 250 N on the entire operatingfield.
● Screws included.
OPTIONAL FEATURES● Silicon Carbide mechanical seal.● Special voltages.● Inverter applications.● PT 100 temperature sensor.
Submersiblemotors
L6CSeries
SPECIFICATIONS● Stainless steel outer sleeve.● Shaft extension and coupling
dimensions to NEMA standards.● Class F insulation.● Protection class: IP68● Compensating bellows for internal
liquid expansion.● Axial load supported by Kingsbury-
type thrust bearing.● Mechanical seal protected by
sand guard.● Maximum immersion depth: 250m● Maximum number of starts per
hour, at regular intervals:25 for direct start.
● Maximum supply voltage variationsallowed : ±10%
● Maximum water temperature: 35°C.Max. temperature applies to motorsworking in an installation capable ofdelivering a flow of water around themotor jacket of at least 0.2 m/s.
❏ HIGH STATICTORQUE
❏ POWER SUPPLYCABLE WITHEXTRACTABLECONNECTOR
Submersible liquid-cooled motors.The choice of component materials ensures optimumoperating performances, superior quality, reliability andease of installation.
IDENTIFICATION CODE
L6C 110 T 40 5
5 = 50 Hz6 = 60 Hz
RATED VOLTAGE
T = THREE-PHASE
RATED POWER IN kW x 10
L6C SERIES NAME
EXAMPLE: L6C110T405
L6C MOTOR:RATED POWER 11 kW; THREE-PHASE;RATED VOLTAGE 400 V; 50Hz
28
L6C SERIES MOTORSMOTOR CROSS SECTION AND TABLE OF MATERIALS
REF. NAME MATERIAL
N° EUROPE USA
1 Flange, inner and outer sleeve Stainless steel EN 10088-1-X5CrNi18-10 (1.4301) AISI304 Shaft extension (up to 18.5 kW) Stainless steel EN 10088-3-X5CrNiMo17-12-2 (1.4401) AISI316 Shaft extension (from 22 kW) Stainless steel (Duplex) EN 10095 X3CrNiMoN27-5-2 (1.4460) AISI329
3 Upper support Cast iron EN-GJL-200 Class 25 B4 Intermediate support Cast iron EN-GJL-200 Class 25 B5 Mechanical seal6 Elastomers7 Lower support Cast iron EN-GJL-200 Class 25 B8 Compensating bellows9 Bearings
10 Cable11 Fixed sand guard Stainless steel EN 10088-1-X5CrNi18-10 (1.4301) AISI30412 Removable sand guard13 Bolts and screws Stainless steel EN 10088-1-X5CrNi18-10 (1.4301) AISI30414 Lower cover Stainless steel EN 10088-1-X5CrNi18-10 (1.4301) AISI30415 Mechanical seal spacer16 Sand guard gasket
Cooling liquidl6c-2p50_c_tm
REFERENCE STANDARDS
Allumina - graphite NBR
NBR
Demineralized water + antifreeze
NBR
2
nickel plated A105 CR neoprene
EPDM Carbon-graphite
29
L6C SERIES MOTORSDIMENSIONS AND WEIGHTS AT 50 Hz
MOTOR DIMENSIONS mm WEIGHT
TYPE kW HP A kg
L6C40T 4 5,5 600 39,4L6C55T 5,5 7,5 631 43,2L6C75T 7,5 10 660 45,2L6C93T 9,3 12,5 685 48,8
L6C110T 11 15 730 52,8L6C150T 15 20 785 59L6C185T 18,5 25 860 66,4L6C220T 22 30 920 72,4L6C300T 30 40 1050 85L6C370T 37 50 1180 98
l6c-2p50_b_td
RATED POWER
30
L6C SERIES MOTORSTHREE-PHASE OPERATING CHARACTERISTICS AT 50 Hz
MOTOR RATED MAX WATER
TYPE VOLTAGE TEMPERATURE
RATED
THREE-PHASE CURRENT
kW HP V A rpm η % cosϕ Ca/Cn Ia °C Ncxsec.(mm2) L (m)
380 10,3 2825 75 0,8 1,7 40L6C40T405 4 5,5 400 10,6 2845 74 0,75 1,7 41
415 11 2860 74 0,7 1,7 42380 13,9 2820 77 0,8 1,8 53
L6C55T405 5,5 7,5 400 14 2845 76 0,75 1,8 53415 14,6 2860 76 0,71 1,8 53380 17,6 2820 78 0,82 2 69
L6C75T405 7,5 10 400 18 2840 77 0,78 2 70415 18,3 2850 77 0,73 2 73380 21,7 2820 78 0,82 2,1 83
L6C93T405 9,3 12,5 400 22 2840 79 0,8 2,1 85415 22,8 2850 78 0,79 2,15 88380 25 2815 77 0,87 2,1 113
L6C110T405 11 15 400 25,5 2840 78 0,82 2,1 115415 26 2845 77 0,79 2,15 118380 33,5 2810 80 0,84 2,2 137
L6C150T405 15 20 400 33,4 2840 81 0,8 2,2 137415 34,2 2850 81 0,76 2,25 140380 40,5 2820 81 0,83 2,3 176
L6C185T405 18,5 25 400 41 2845 82 0,8 2,3 177415 42 2855 82 0,73 2,35 180380 47,5 2810 81 0,88 2,3 191
L6C220T405 22 30 400 47 2825 82 0,84 2,3 195415 47,5 2835 82 0,8 2,35 198380 63 2810 82 0,89 2,4 250
L6C300T405 30 40 400 61,5 2830 82 0,85 2,4 250415 63,5 2840 81 0,8 2,45 250380 79,5 2820 82 0,87 2 296
L6C370T405 37 50 400 79,3 2830 81 0,84 2,2 310415 80 2840 81 0,8 2,3 320
l6c-2p50_c_te
4x4
4
4
4x8
4
4
4
4x6 4
4x8
4
4x4 4
4x4
CABLE TYPERATED
POWER
OPERATING CHARACTERISTICS
AT RATED POWER
DIRECT
START
4x4 4
4x4
35
35
35
35
4x4
4x4
4
35
35
35
35
35
35
31
Submersiblemotors
MC8Series
APPLICATIONThree-phase asynchronous submersible water filledmotor, with short-circuit rotor and special water-resistantwindings.The choice of component materials ensures optimumoperating performances, high reliability and ease ofinstallation.
SPECIFICATIONS• Shaft extension and coupling
dimensions to NEMA standardsRewindable stator PVCinsulationProtection class: IP58Fill liquidThe motors are filled with watercontaining non-toxic antifreeze(15%). This liquid, besidesprotecting the motor from lowtemperatures, helps to inhibitoxidation and improve lubrication.
• Large compensatingdiaphragm for internal liquidexpansion. The motor is alsoequipped with a relief valveenabling the escape of liquid in theevent of abnormal temperatureincreases.
• Axial load supported by oscillatingbearing.
• To prevent fluid exchange betweenthe external and internalenvironments, all the standardmotors are equipped with two lipseals.Motors with mechanical seal areavailable on request.
• Maximum immersion depth: – 40 m for standard motors
(lip seal)– 350 m for motors with
mechanical seal (on request).• Maximum number of evenly
distributed starts per hour: 10
• Maximum supply voltage (400 V)variations:+6%-10%.
• Maximum axial thrust: 50,000 N.• Available versions
MC8 three-phase 30 kW to 92 kW400VDifferent voltages available on request
• PVC winding• The motors are supplied with three 5-
metre lengths of H07BBF-type circularsingle-core cable.
• Ambient temperature: 25°C; themotors must operate in installationsensuring a minimum water velocityaround the motor sleeve of 0.20 m/s.
OPTIONALFEATURES• 4-pole motors.• Special voltages of up to 1000 V.• Horizontal installation.• Inverter applications.• High temperature windings.• Different materials.
ACCESSORIES • Panels.• Drop cables.
32
MC8 SERIES MOTORSDIMENSIONS AND WEIGHTS AT 50 Hz
MOTOR DIMENSIONS (mm) WEIGHT
TYPE
kW HP L kg
MC 8 - 40 30 40 1015 145MC 8 - 50 37 50 1105 162MC 8 - 60 44 60 1195 180MC 8 - 70 52 70 1285 200MC 8 - 75 55 75 1325 206MC 8 - 80 59 80 1375 217MC 8 - 90 66 90 1465 235MC 8 - 100 75 100 1555 252MC 8 - 125 92 125 1755 290
mc 8-2p50_a_td
INPUT
POWER
OPERATING CHARACTERISTICS AT 50 Hz
MOTOR RATED MAX
TYPE VOLTAGE WATER
RATED TEMPERATURE
THREE-PHASE CURRENT
kW HP V A rpm η % cosϕ Ca/Cn Ia/In °C Ncxsez.(mm2) L (m)
380 65 2905 83 0.85 1.2 4.67 3x10 5415 59 2900 83 0.84 1.09 4.7 3x10 5380 82.5 2860 82 0.85 1.16 4.62 3x10 5415 76 2860 82 0.85 1.17 4.64 3x10 5380 94 2870 84 0.86 0.95 4.10 3x16 5415 85 2870 85 0.86 0.99 4.23 3x16 5380 112 2865 82 0.85 1.14 5.83 3x16 5415 104 2865 82.5 0.85 1.16 5.8 3x16 5380 118 2850 82 0.86 1.26 4.90 3x16 5415 110 2850 82.5 0.86 1.27 4.84 3x16 5380 125 2875 84 0.86 1.21 4.55 3x16 5415 115 2870 83.5 0.85 1.20 4.51 3x16 5380 141 2870 84 0.86 1.08 4.60 3x16 5415 130 2870 84 0.85 1.16 4.74 3x16 5380 156 2875 83 0.86 1.03 4.61 3x25 5415 144 2880 83 0.85 1.10 4.71 3x25 5380 192 2885 85 0.86 0.93 4.24 3x35 5415 176 2885 84.5 0.85 0.97 4.32 3x35 5
mc8-2p50_a_te
MC8-40 30 40
25
25
25
25
MC8 -50
MC8-60
MC8-75
CABLE TYPERATED
OUTPUT
25
OPERATING CHARACTERISTICS
AT RATED OUTPUT
DIRECT
START
MC8-90
MC8-125
MC8-70
MC8-80
MC8-100
37 50
44 60
52 70
55 75
59 80
66 90
75 100
92 125
25
25
25
25
33
Submersiblemotors
MC10Series
SPECIFICATIONS• Rewindable stator PVC
insulationsProtection class: IP58Fill liquidThe motors are filled with watercontaining non-toxic antifreeze(15%). This liquid, besidesprotecting the motor from lowtemperatures, helps to inhibitoxidation and improve lubrication.
• Large compensatingdiaphragm for internal liquidexpansion. The motor is alsoequipped with a relief valveenabling the escape of liquid in theevent of abnormal temperatureincreases.
• Axial load supported by oscillatingbearing.
• To prevent fluid exchange betweenthe external and internalenvironments, all the standardmotors are equipped with two lipseals.Motors with mechanical seal areavailable on request.
• Maximum immersion depth: – 40 m for standard motors (lip
seal)– 350 m for motors with
mechanical seal (on request).• Maximum number of evenly
distributed starts per hour: 8
• Maximum supply voltage (400 V)variations:+6%-10%.
• Maximum axial thrust: 65,000 N.• Available versions
MC10 three-phase 92 kW to 150 kW400VDifferent voltages available on request
• PVC winding• The motors are supplied with three 5-
metre lengths of H07BBF-type circularsingle-core cable.
• Ambient temperature: 25°C; themotors must operate in installationsensuring a minimum water velocityaround the motor sleeve of 0.20 m/s.
OPTIONALFEATURES• 4-pole motors.• Special voltages of up to 1000 V.• Horizontal installation.• Inverter applications.• High temperature windings.• Different materials.
ACCESSORIES • Panels.• Drop cables.
APPLICATIONSThree-phase asynchronous submersible water filledmotor, with short-circuit rotor and special water-resistantwindings.The choice of component materials ensures optimumoperating performances, high reliability and ease ofinstallation.
34
MC10 SERIES MOTORSDIMENSIONS AND WEIGHTS AT 50 Hz
OPERATING CHARACTERISTICS AT 50 Hz
MOTOR DIMENSIONS (mm) WEIGHT
TYPE
kW HP L kg
MC 10-125 92 125 1562 360MC 10-150 110 150 1702 401MC 10-175 129 175 1852 448MC 10-200 150 200 1982 487
mc 10-2p50_a_td
INPUT
POWER
MOTOR RATED MAX
TYPE VOLTAGE WATER
RATED TEMPERATURE
THREE-PHASE CURRENT
kW HP V A rpm η % cosϕ Ca/Cn Ia/In °C Ncxsez.(mm2) L (m)
380 190 2910 85 0.85 1.02 5.30 3x35 5415 177 2910 85 0.85 1.06 5.31 3x35 5380 237 2905 86.5 0.84 1.41 5.63 3x50 5415 216 2905 85.5 0.84 1.44 5.7 3x50 5380 274 2915 86 0.83 1.57 5.80 3x70 5415 250 2915 86.5 0.83 1.54 5.78 3x50 5380 312 2930 85 0.84 1.64 5.82 3x70 5415 292 2925 84.5 0.85 1.59 5.6 3x70 5
mc10-2p50_a_te
MC10-125 92 125
25
25
25
MC10-150
MC10-175
MC10-200 150 200
CABLE TYPERATED
OUTPUT
25
OPERATING CHARACTERISTICS
AT RATED OUTPUT
DIRECT
START
110 150
129 175
35
Submersiblemotors
AISI 316F6 Series
SPECIFICATIONS• Stainless steel outer casing• Shaft extension and coupling
dimensions to NEMA standards.• Watertight stator• Insulation class: F.• Shaft supported by bearings
lubricated by fill liquid.• Mechanical seal.• Maximum immersion
depth:350 metres.
• Maximum number of evenlydistributed starts per hour:20 for direct start.
• Versions:– F6 three-phase from 4 to 45 kW,
380-415 V, 50 Hz.• Removable power supply
cable fitted with watertightconnector.
• F6 motors with dual cable outlet forstar-delta starting are available onrequest; three-phase 220 V and 500V motors are also available.
• The maximum temperature atwhich the motors operate in a 6”well or in any other installationshould ensure a minimum watervelocity over the motor of at least0.16 m/s.
● Operating position: vertical andhorizontal.
Water-filled submersible motors.The choice of component materials ensures optimumoperating performances, superior quality, reliability andease of installation.
F6 MOTORMATERIALS
PART NAME MATERIAL
Outer sleeve Stainless steel1.4571
Shaft extension Stainless steel1.4542
Upper and lower support 1.4408Mechanical seal SiC/SiCElastomers Nitrile rubber
and buna NLower protection Stainless steel
1.4401Compensating EPDMbellowsCooling liquid Distilled water +
antifreeze
36
OPERATING CHARACTERISTICS AT 50 Hz
F6../316 SERIES MOTORSDIMENSIONS AND WEIGHTS AT 50 Hz
MOTORS DIMENSIONS (mm) WEIGHT
TYPE
kW HP A kg
F605T534/316 4 5,5 571 37,5F607T534/316 5,5 7,5 604 41,1F610T534/316 7,5 10 636 45,2F612T534/316 9,3 12,5 669 47,5F615T534/316 11 15 701 50,9F620T534/316 15 20 766 56,7F625T534/316 18,5 25 831 63,3F630T534/316 22 30 896 69,3F640T534/316 30 40 1026 83,9F650T534/316 37 50 1395 135
f6-316-2p50_a_td
NOMINAL
POWER
MOTOR RATED MAX.
TYPE VOLTAGE WATER
RATED TEMPERATURE
THREE-PHASE CURRENT
kW HP V A rpm η % cosϕ Ca/Cn Ia °C Ncxsec.(mm2) L (m)
380 9,5 2840 77 0,85 1,43 42 4G4 4F605T534/316 4 5,5 400 9,3 2860 78 0,82 1,64 43 30 4G4 4
415 9,3 2880 78,5 0,78 1,69 46 4G4 4380 12,8 2850 78 0,85 1,62 60 4G4 4
F607T534/316 5,5 7,5 400 12,5 2870 79 0,82 1,88 64 30 4G4 4415 12,8 2880 78 0,78 1,93 66 4G4 4380 16,3 2850 79 0,87 1,72 83 4G4 4
F610T534/316 7,5 10 400 16 2860 79 0,86 1,9 83 30 4G4 4415 16,2 2880 79 0,81 2,07 91 4G4 4380 21 2870 81 0,86 1,98 106 4G4 4
F612T534/316 9,3 12,5 400 20,7 2870 81 0,8 2,19 112 30 4G4 4415 21 2890 80 0,78 2,40 116 4G4 4380 24 2860 81 0,87 1,94 126 4G4 4
F615T534/316 11 15 400 23,3 2860 81 0,85 2,09 129 30 4G4 4415 24,1 2870 79,5 0,81 2,27 136 4G4 4380 32 2850 82 0,86 2,08 164 4G4 4
F620T534/316 15 20 400 31,3 2860 81 0,85 2,15 169 30 4G4 4415 31 2870 81 0,83 2,35 179 4G4 4380 40 2850 82 0,87 2,23 220 4G4 4
F625T534/316 18,5 25 400 38,5 2850 82 0,85 2,47 231 30 4G4 4415 38,5 2850 82 0,83 2,68 240 4G4 4380 47 2840 82 0,88 2,12 255 4G4 4
F630T534/316 22 30 400 45,3 2860 83 0,86 2,37 268 30 4G4 4415 45 2870 82,5 0,84 2,54 278 4G4 4380 64,1 2860 82,5 0,85 2,38 373 3x8.4+1G8.4 4
F640T534/316 30 40 400 63,5 2860 83 0,84 2,64 393 30 3x8.4+1G8.4 4415 64,5 2880 82,5 0,81 2,86 407 3x8.4+1G8.4 4380 80 2840 83,5 0,86 2,02 390 3x8.4+1G8.4 4
F650T534/316 37 50 400 73 2880 84,5 0,87 2,27 410 30 3x8.4+1G8.4 4415 73,5 2890 84,7 0,85 2,45 426 3x8.4+1G8.4 4
F6-316-2p50_a_te
CABLE TYPERATED
POWER
OPERATING CHARACTERISTICS
AT RATED POWER
DIRECT
START
37
Submersiblemotors
FW8Series
SPECIFICATIONS• Shaft extension and coupling
dimensions to NEMA standards.Rewindable statorPVC insulationProtection class: IP68Fill liquidThe motors are filled with watercontaining non-toxic antifreeze. Thisliquid, besides protecting the motorfrom low temperatures, helps toinhibit oxidation and improvelubrication.
• Large compensatingdiaphragm for internal liquidexpansion. The motor is alsoequipped with a relief valveenabling the escape of liquid in theevent of abnormal temperatureincreases.
• Axial load supported by oscillatingbearing.
• To prevent fluid exchange betweenthe external and internalenvironments, all the standardmotors are equipped with a siliconcarbide mechanical seal.
• Maximum immersion depth:350 metres.
• Maximum number of evenlydistributed starts per hour: 10
• Maximum supply voltage variation(415 V +6%, 380 V –10%).
• Maximum axial thrust: 45,000 N.• Available versions:
FW8 three-phase: 45 kW to 93 kW380-415 V; different voltagesavailable on request.
• PVC winding• The motors are supplied with 6 m
cable.• Ambient temperature: 30°C. The
motors must operate in installationsensuring a minimum water velocityaround the motor sleeve of 0.20m/s for 30-52 kW, 0.5 m/s for 55-93 kW.
OPTIONALFEATURES• Special voltages.• Horizontal installation: all models
except for the 93 kW one.• Inverter applications.• High temperature windings.• Different materials.
ACCESSORIES• Panels.• Drop cables.
APPLICATIONSThree-phase asynchronous submersible water-filledmotor, with short-circuit rotor and special water resistantwindings.The choice of component materials ensures optimumoperating performances, superior quality, reliability andease of installation.
38
OPERATING CHARACTERISTICS AT 50 Hz
kW HP L kg
FW845T405 45 60 1230 156FW852T405 52 70 1340 179FW855T405 55 75 1340 179FW860T405 60 80 1470 198FW867T405 67 90 1470 198FW875T405 75 100 1560 215FW883T405 83 112 1560 247FW893T405 93 125 1740 247
fw8-2p50_b_td
MOTOR DIMENSIONS (mm) WEIGHT
TYPE
RATED
POWER
MAX WATER
TEMPERATURE
Ncxsez. L
kW HP V A rpm η % cosϕ Ca/Cn Ia °C mm2 m
380 93 2900 85,2 0,88 1,46 491 4G10 6400 90 2910 85,9 0,86 1,62 520 4G10 6415 89 2910 85,8 0,84 1,77 541 4G10 6380 107 2900 85,3 0,89 1,62 575 4G16 6400 103 2910 86,2 0,87 1,81 608 4G16 6415 101 2920 86,7 0,85 1,98 633 4G16 6380 114 2900 85,7 0,88 1,65 624 4G16 6400 110 2915 86,4 0,86 1,87 660 4G16 6415 109 2920 86,2 0,84 2,02 688 4G16 6380 122 2900 86,5 0,89 1,61 698 4G16 6400 116 2910 87,0 0,88 1,81 725 4G16 6415 115 2920 87,1 0,86 1,96 768 4G16 6380 137 2900 86,4 0,89 1,60 759 3x25 6400 133 2910 86,9 0,86 1,79 797 3x25 6415 131 2920 86,6 0,84 1,94 828 3x25 6380 154 2900 85,9 0,89 1,69 892 3x25 6400 148 2910 86,7 0,87 1,91 942 3x25 6415 147 2920 86,6 0,84 2,08 982 3x25 6380 166 2910 87,2 0,89 1,75 1019 3x25 6400 160 2920 87,6 0,88 1,99 1077 3x25 6415 156 2925 88,0 0,86 2,14 1120 3x25 6380 188 2910 87,5 0,88 1,82 1186 3x25 6400 183 2920 87,8 0,86 2,05 1276 3x25 6415 184 2930 87,7 0,83 2,21 1308 3x25 6
fw8-2p50_b_te
30
30
30
100
83 112
93 125
52
55
75
75
60 80
67 90
FW883T405
FW860T405
FW875T405
FW893T405
FW867T405
CABLE TYPE
30FW845T405 45 60
30
30
30
30
FW852T405
FW855T405
70
MOTOR RATED
TYPE VOLTAGE
RATED
THREE-PHASE CURRENT
RATED
POWER
OPERATING CHARACTERISTICS
AT RATED POWER
DIRECT
START
FW8 SERIES MOTORSDIMENSIONS AND WEIGHTS AT 50 Hz
39
Submersiblemotors
FW10Series
APPLICATIONSThree-phase asynchronous submersible water-filledmotor, with short-circuit rotor and special water resistantwindings.The choice of component materials ensures optimumoperating performances, superior quality, reliability andease of installation.
SPECIFICATIONS• Shaft extension and coupling
dimensions to NEMA standards.Rewindable statorPVC insulationProtection class: IP68Fill liquidThe motors are filled with watercontaining non-toxic antifreeze(15%). This liquid, besidesprotecting the motor from lowtemperatures, helps to inhibitoxidation and improve lubrication.
• Large compensatingdiaphragm for internal liquidexpansion. The motor is alsoequipped with a relief valveenabling the escape of liquid in theevent of abnormal temperatureincreases.
• Axial load supported by oscillatingbearing.
• To prevent fluid exchange betweenthe external and internalenvironments, all the standardmotors are equipped with a siliconcarbide mechanical seal.
• Maximum immersion depth:350 meters.
• Maximum number of evenlydistributed starts per hour: 8
• Maximum supply voltage variation(415 V +6%, 380 V –10%).
• Maximum axial thrust: 60,000 N.• Available versions:
FW10 three-phase: 110 kW to185 kW380-415 V; different voltages
available on request.• PVC winding• The motors are supplied with 6 m
cable.• Ambient temperature: 25°C. The
motors must operate in installationsensuring a minimum water velocityaround the motor sleeve of0.50 m/s.
OPTIONALFEATURES• Special voltages.• Horizontal installation: all models
except for the 185 kW one.• Inverter applications.• High temperature windings.• Different materials.
ACCESSORIES• Panels.• Drop cables.
40
FW10 SERIES MOTORSDIMENSIONS AND WEIGHTS AT 50 Hz
OPERATING CHARACTERISTICS AT 50 Hz
kW HP L kg
FW10110T405 110 150 1529 315FW10130T405 130 175 1659 362FW10150T405 150 200 1769 413FW10185T405 185 250 1919 449
fw10-2p50_b_td
MOTOR DIMENSIONS (mm) WEIGHT
TYPE
RATED
POWER
Ncxsez. L
kW HP V A rpm % cos Ca/Cn Ia °C mm2 m
380 235 2910 86 0,85 1,15 1095 3x50 6400 232 2920 86 0,82 1,29 1158 3x50 6415 233 2920 86 0,79 1,40 1206 3x50 6380 266 2900 87 0,87 1,13 1271 3x50 6400 256 2920 88 0,86 1,28 1344 3x50 6415 255 2920 87 0,83 1,39 1400 3x50 6380 307 2910 86 0,88 1,15 1502 3x50 6400 298 2920 87 0,85 1,29 1590 3x50 6415 296 2930 87 0,83 1,40 1655 3x50 6380 390 2900 87 0,85 1,49 2030 3x50 6400 384 2920 88 0,81 1,68 2148 3x50 6415 389 2920 86 0,79 1,83 2237 3x50 6
(*) Available with connection only Y∆ fw10-2p50_a_te
25
25
25
FW10130T405
(*)FW10150T405
175
(*)FW10185T405
185 250
25110 150FW10110T405
130
150 200
ϕη
MAX WATER
TEMPERATURE
CABLE TYPEMOTOR RATED
TYPE VOLTAGE
RATED
THREE-PHASE CURRENT
RATED
POWER
OPERATING CHARACTERISTICS
AT RATED POWER
DIRECT
START
41
ACCESSORIES
Serie SCUBAISO Threaded Flanges.................................................................. 42
Serie SCUBASupporting Collars....................................................................... 43
Serie SCUBAMotor-Control Panel Combination Table ...................................... 44
Serie SCUBAElectrical Panels ........................................................................... 46
Serie SCUBALevel control panels..................................................................... 52
Serie SCUBALevel probe module..................................................................... 53
Serie SCUBALightning protection.................................................................... 54
Serie SCUBACooling shrouds .......................................................................... 55
42
ISO-THREADED FLANGES
ISO 7-1G DN PN Ø D Ø d Ø K Z Ø L C L1 I2
125 10÷16 250 - 210 8 18 22 108 44 A125 25÷40 270 188 220 8 26 26 168 44 C125 63 295 188 240 8 30 34 188 44 C150 10÷16 285 - 240 8 22 22 248 44 B150 25÷40 300 218 250 8 26 28 315 44 D150 63 345 218 280 8 33 36 335 44 D
z8-flange_a_td
Z855Z875Z895
Z8125
R 5
PUMP THREADINGTYPE
TYPE
* Flanges according to ASME B16.5 are available on request.
Dimensions (mm)
* Flange according to EN 1092-1
ACCESSORIES
43
CARRYING CLAMPS
A B C E SCREW kg kg/m kg/m kg/m65 R 2 1/2" 50 15 600 130 M16x90 1300 6,7 8,0 3,380 R 3" 80 15 600 180 M20x70 3400 8,4 10,5 5,0
100 R 4" 80 15 600 180 M20x110 3400 20,5 15,0 7,9125 R 5" 100 20 600 260 M24x90 7250 27,5 18,5 12,3150 R 6" 100 20 600 260 M24x130 7250 33,0 22,0 17,6175 R 7" 120 25 800 360 M30x110 9750 27,0 25,5 24,0200 R 8" 120 25 800 360 M30x150 9750 33,0 34,0 31,5250 R 10" 120 25 800 360 M30x220 9750 48,0 48,0 49,0
1) Max admissible weight. clamp_a_td
NOTE. Two sets of supporting collars are necessary for installation.
THREADED WATER
PIPE WEIGHTCARRYING CLAMPS
Dimensions (mm) FLANGED
NOMINAL PIPE DIAMETERDN Pmax (1)
ACCESSORIES
44
MOTOR-CONTROL PANEL COMBINATION TABLE
MOTOR TYPE RATED CAPACITOR
L6C - 6" CURRENT
THREE-PHASE 380-415 V
kW HP A µF / 450 V QTD/… Q3D/… Q3I/… Q3A/… Q3Y/… Q3SF/…
4 5,5 11,0 - …55 …55 …55 …55 …55 …755,5 7,5 14,6 - …92 …92 …92 …92 …55 …757,5 10 18,3 - …92 …92 …92 …92 …92 …1509,3 12,5 22,8 - - …110 …110 …110 …92 …15011 15 26,0 - - …110 …110 …110 …110 …15015 20 34,2 - - …150 …150 …150 …150 …220
18,5 25 42,0 - - …220 …220 …220 …220 …22022 30 47,5 - - …300 …300 …300 …220 …30030 40 63,5 - - …370 …370 …370 …370 …37037 50 80,0 - - - …550 …550 …550 …550
For different voltages please contact our sales network. L6c-2p50_c_tc
POWER
RATED PANEL TYPE
MOTOR RATED CAPACITOR
TYPE CURRENT
380-415 V
kW HP A µF / 450 V Q3D/… Q3I/… Q3A/… Q3SF/…
30 40 65 - …370 …370 …370 …37037 50 82,5 - (1) …550 …550 …55044 60 94 - (1) …550 …550 …55052 70 112 - (1) …750 …750 …59055 75 118 - (1) …750 …750 …59059 80 125 - - …750 …750 …75066 90 141 - - …900 …900 …90075 100 156 - - …900 …900 …90092 125 192 - - …1100 …1100 …900
MC8-2p50_a_tc
MC8 - 8"
RATED PANEL TYPE
POWER
MOTOR RATED CAPACITOR
TYPE CURRENT
380-415 V
kW HP A µF / 450 V Q3I/… Q3A/… Q3SF/…
92 125 190 - …1100 …1100 …1100110 150 237 - …1100 …1100 …1100129 175 274 - (1) (1) (1)150 200 312 - (1) (1) (1)
(1) On request. MC10-2p50_a_tc
For different voltages please contact our sales network.
MC10 - 10"
RATED PANEL TYPE
POWER
ACCESSORIES
MOTOR TYPE RATED CAPACITOR
F6../316 CURRENT
THREE-PHASE 380-415 V
kW HP A µF / 450 V QTD/… Q3D/… Q3I/… Q3A/… Q3SF/…
4 5,5 9,5 - …30 …30 …55 …55 …755,5 7,5 12,8 - …55 …55 …55 …55 …757,5 10 16,3 - …92 …92 …92 …92 …15011 15 24,1 - - …110 …110 …110 …15015 20 32,0 - - …150 …150 …150 …220
18,5 25 40,0 - - …220 …220 …220 …22022 30 47,0 - - …220 …300 …300 …30030 40 64,5 - - …370 …370 …370 …37037 50 80,1 - - - …550 …550 …45045 60 95,5 - - - …750 …750 …550
For different voltages please contact our sales network. z6-f6-316-2p50_a_tc
RATED PANEL TYPE
POWER
45
MOTOR-CONTROL PANEL COMBINATION TABLE
ACCESSORIES
MOTOR RATED CAPACITOR
TYPE CURRENT
380-415 V
kW HP A µF / 450 V Q3D/… Q3I/… Q3A/… Q3SF/…
45 60 93 - (1) …550 …550 …55052 70 107 - (1) …750 …750 …59055 75 114 - (1) …750 …750 …59060 80 122 - (1) …750 …750 …75067 90 137 - (1) …900 …900 …90075 100 154 - (1) …900 …900 …90083 112 166 - - …900 …900 …90093 125 188 - - …1100 …1100 …1100
fw8-2p50_a_tc
FW8 - 8"
RATED PANEL TYPE
POWER
MOTOR RATED CAPACITOR
TYPE CURRENT
380-415 V
kW HP A µF / 450 V Q3I/… Q3A/… Q3SF/…
110 150 235 - …1100 …1100 …1100130 175 266 - (1) (1) (1)150 200 307 - (1) (1) (1)185 250 390 - (1) (1) (1)
fw10-2p50_a_tc
FW10 - 10"
RATED PANEL TYPE
POWER
46
ACCESSORIESThree-PhaseElectric Panel
QTD Series
APPLICATIONS• Protection and control of a three-phase submersible electric
pump.
SPECIFICATIONS•Control through an external enable
contact.
•Supply voltage: 3 x 400 V ±10 %.
•Frequency: 50/60 Hz
•Power: 0.37 to 9.2 kW.
•Direct motor start.
•Protection class: IP 54.
•Ambient temperature: -5 to +40 °C(limit specified by EN Standard60439-1).
•Maximum relative humidity: 50% at+40°C, provided that nocondensation occurs (limit specifiedby EN standard 60439-1).
•Wall mounted.
•Metal enclosure.
•Ready for installation of dryrunning control float or pressureswitch (to be ordered separately).
•Power and thermal overloadindicator lights.
OPTIONALACCESSORIES•VR3 three-phase module for
overvoltage protection (lightningprotector).
•SLD series 24V level kit.Probe module for protection againstdry running (set of three electrodesincluded in the supply).
QTD/03 0,37 0,5 0.9-1.5QTD/05 0,55 0,75 1.4-2.3QTD/11 1,1 1,5 2.0-3.3QTD/15 1,5 2 3.0-5.0QTD/22 2,2 3 4.5-7.5 235x265x150 5,8QTD/30 3 4 6.0-10.0QTD/40 4 5,5 9.0-12.0QTD/55 5,5 7,5 9.0-15.0QTD/92 9,2 12,5 14.0-23.0
PANEL RATED APPLICATION DIMENSIONS WEIGHTTYPE POWER RANGE A x B x C WITH
PACKING
kW HP A mm kg
Line protection to be provided by the user.
For proper selection, make sure that the ampere input of the electric motor matches the values specified in the table.
47
ACCESSORIESThree-PhaseElectricPanel
Q3D Series
APPLICATIONS
• Protection and control of a three-phase submersible electricpump.
SPECIFICATIONS•Manual control through an
Auto/Man selector switch.
•Automatic control through anexternal enable contact.
•Supply voltage: 3 x 400 V ±10 %.Frequency: 50/60 Hz.
•24 V AC low voltage auxiliary circuit.
•Power: 0.37 to 37 kW.
•Direct start.
•Protection class: IP 54.
•Ambient temperature: -5 to +40 °C(limit specified by EN Standard60439-1).
•Maximum relative humidity: 50% at+40°C, provided that nocondensation occurs (limit specifiedby EN standard 60439-1).
•Wall mounted.
•Metal enclosure.
•Power, pump running, thermaloverload and dry running indicatorlights.
•Manual-reset thermal relay foroverload protection, sensitive tophase failure.
•Ready for installation of dry running
control float or pressure switch (tobe ordered separately).Can be equipped with electronicprotection module with electrodes.
OPTIONALACCESSORIES•SLD series 24V level kit.
Probe module for protection againstdry running (set of three electrodesincluded in the supply).
•Float.
•Pressure switch.
•VR3 three-phase module forovervoltage protection (lightningprotector).
Q3D/03 0,37 0,5 0,9-1,5Q3D/05 0,5 0,75 1,4-2,3Q3D/11 1,1 1,5 2,0-3,3Q3D/15 1,5 2,0 3,0-5,0Q3D/22 2,2 3,0 4,5-7,5 300 x 400 x 200 15Q3D/30 3 4,0 6,0-10,0Q3D/40 4 5,5 9,0-12,0Q3D/55 5,5 7,5 9,0-15,0Q3D/92 9,2 12,5 14,0-23,0Q3D/110 11 15 20,0-32,0
400 x 500 x 200Q3D/150 15 20 28,0-38,0
20
Q3D/220 22 30 35,0-50,0Q3D/300 30 40 45,0-63,0 400 x 600 x 200 27Q3D/370 37 50 60,0-80,0
PANEL RATED APPLICATION DIMENSIONS WEIGHT TYPE POWER RANGE A x B x C WITH
PACKING
kW HP A mm kg
Line protection to be provided by the user.
For proper selection, make sure that the ampere input of the electric motor matches the values specified in the table.
48
Three Phaseelectricpanel
Q3Y Series
APPLICATIONS
• Protection and control of a three-phase borehole pump.
OPTIONALACCESSORIES•SLD series 24V level kit.
Probe module for protection againstdry running (set of three electrodesincluded in the supply).
•Float.
•Pressure switch.
•VR3 three-phase module forovervoltage protection (lightningprotector).
Q3Y/40 4 5,5 8,0-12,0Q3Y/55 5,5 7,5 11,0-16,0Q3Y/92 7,5 - 9,2 10 - 12,5 16,0-24,0 400 x 600 x 200 23Q3Y/110 11 15 24,0-32,0Q3Y/150 15 20 30,0-40,0Q3Y/220 18,5 - 22 25 - 30 35,0-50,0
500 x 700 x 200 32Q3Y/300 30 40 50,0-62,0Q3Y/370 37 50 60,0-80,0Q3Y/550 45 - 55 60 - 75 80,0-110,0 600 x 800 x 250 80Q3Y/750 75 100 90,0-140,0Q3Y/900 90 125 135,0-180,0 600 x 1300 x 300 floor
100-120Q3Y/1100 110 150 180,0-250,0 600 x 1500 x 300 floor
Line protection to be provided by user.
For proper selection, make sure that the ampere input of the electric motor falls within the application range shownin the table.
PANEL TYPE RATED APPLICATION DIMENSIONS WEIGHT POWER RANGE A x B x C WITH
PACKING
kW HP A mm kg
SPECIFICATIONS •Manual control through Auto/Man
selector switch.
•Automatic control through anexternal enable contact.
•Supply voltage: 3 x 400 V ±10 %.Frequency: 50/60 Hz.
•24 V AC low voltage auxiliary circuit.
•Power: 4 to 110 kW.
•Star-delta starting.
•Protection class: IP 54.
•Ambient temperature: -5 to +40 °C(limit specified by EN standard60439-1).
•Maximum relative humidity: 50% at+40°C, provided that nocondensation occurs (limit specifiedby EN standard 60439-1).
•Wall mounted.
•Metal enclosure.
•Power - pump running - thermaloverload - dry running indicatorlights.
•Manual-reset thermal relay foroverload protection, sensitive tophase failure.
•Ready for installation of dry runningcontrol float or pressure switch (tobe ordered separately).Can be fitted with electronicprotection module with electrodes.
ACCESSORIES
49
ACCESSORIESACCESSORIESThree-PhaseElectricPanel
Q3I Series
APPLICATIONS
• Protection and control of a three-phase submersible electricpump.
SPECIFICATIONS•Manual control through an
Auto/Man selector switch.
•Automatic control through externalenable contact.
•Supply voltage: 3 x 400 V ±10 %.Frequency: 50/60 Hz.
•Auxiliary low-voltage circuit:24 V AC.
•Power: 5.5 to 110 kW.
•Impedance start.
•Protection class: IP 54.
•Ambient temperature: -5 to +40 °C(limit specified by EN Standard60439-1).
•Maximum relative humidity: 50% at+40°C, provided that nocondensation occurs (limit specifiedby EN standard 60439-1).
•Wall mounted.
•Metal enclosure.
•Power - pump running - thermaloverload - dry running indicatorlights.
•Manual-reset thermal relay foroverload protection, sensitive tophase failure.
•Ready for installation of dry runningcontrol float or pressure switch (tobe ordered separately).Can be equipped with electronicprotection module with electrodes.
OPTIONALACCESSORIES•SLD series 24V level kit.
Probe module for protection againstdry running (set of three electrodesincluded in the supply).
•Float.
•Pressure switch.
•VR3 three-phase module forovervoltage protection (lightningprotector).
Q3I/55 5,5 7,5 9,0-15,0 400 x 600 x 250 35
Q3I/92 7,5 - 9,2 10 - 12,5 14,0-23,0 Q3I/110 11 15 20,0-32,0 Q3I/150 12,5 - 15 17 - 20 28,0-38,0 Q3I/220 18,5 - 22 25 - 30 35,0-47,0 500 x 700 x 250 50Q3I/300 30 40 46,0-62,0 Q3I/370 37 50 60,0-78,0 Q3I/550 45 - 55 60 - 75 75,0-110,0 600 x 1300 x 300Q3I/750 75 100 90,0-140,0 floor
100-150Q3I/900 90 125 120,0-180,0 600 x 1500 x 300Q3I/1100 110 150 180,0-250,0 floor
PANEL RATED APPLICATION DIMENSIONS WEIGHT TYPE POWER RANGE A x B x C WITH
PACKING
kW HP A mm kg
Line protection to be provided by the user.
For proper selection, make sure that the ampere input of the electric motor matches the values specified in the table.
50
ACCESSORIES
50
Three-PhaseElectricPanel
Q3A Series
APPLICATIONS• Protection and control of a three-phase submersible electric
pump.
SPECIFICATIONS•Manual control through an
Auto/Man selector switch.
•Automatic control through anexternal enable contact.
•Supply voltage: 3 x 400 V ±10 %.Frequency: 50/60 Hz.
•24 V AC low voltage auxiliary circuit.
•Power: 5.5 to 110 kW.
•Starting autotransformer
•Protection class: IP 54.
•Ambient temperature: -5 to +40 °C(limit specified by EN Standard60439-1).
•Maximum relative humidity: 50% at+40°C, provided that nocondensation occurs (limit specifiedby EN standard 60439-1).
•Wall mounted.
•Metal enclosure.
•Power - pump running - thermaloverload - dry running indicatorlights.
•Manual-reset thermal relay foroverload protection, sensitive tophase failure.
•Ready for installation of dry runningcontrol float or pressure switch (tobe ordered separately).Can be equipped with electronicprotection module with electrodes.
OPTIONALACCESSORIES•SLD series 24V level kit.
Probe module for protection againstdry running (set of three electrodesincluded in the supply).
•Float.
•Pressure switch.
•VR3 three-phase module forovervoltage protection (lightningprotector).
Q3A/55 5,5 7,5 9,0-15,0 Q3A/92 7,5 - 9,2 10 - 12,5 14,0-23,0Q3A/110 11 15 20,0-32,0 500 x 700 x 250 50Q3A/150 12,5 - 15 17 - 20 28,0-38,0 Q3A/220 18,5 - 22 25 - 30 35,0-47,0 Q3A/300 30 40 46,0-62,0
600 x 900 x 300 90Q3A/370 37 50 60,0-78,0 Q3A/550 45 - 55 60 - 75 75,0-110,0 600 x 1500 x 300 Q3A/750 75 100 90,0-140,0 floor
150-200Q3A/900 90 125 120,0-180,0 600 x 1700 x 400 Q3A/1100 110 150 180,0-250,0 floor
PANEL RATED APPLICATION DIMENSIONS WEIGHT TYPE POWER RANGE A x B x C WITH
PACKING
kW HP A mm kg
Line protection to be provided by the user.
For proper selection, make sure that the ampere input of the electric motor matches the values specified in the table.
51
ACCESSORIESThree-PhaseElectricPanel
Q3SF Series
APPLICATIONS
• Protection and control of a three-phase submersible electricpump.
SPECIFICATIONS•Manual control through an
Auto/Man selector switch.•Automatic control through an
external enable contact.•Supply voltage: 3 x 400 V ±10 %.
Frequency: 50/60 Hz.•24 V AC low voltage auxiliary circuit.•Power: 5.5 to 110 kW.•Softstart with torque control.•Protection class: IP 54.•Ambient temperature: -5 to +40 °C
(limit specified by EN Standard60439-1).
•Maximum relative humidity: 50% at+40°C, provided that nocondensation occurs (limit specifiedby EN standard 60439-1).
•Wall mounted.•Metal enclosure.•Dry running indicator light.•Power - pump running - malfunction
LEDs on starter keypanel.•ON/OFF selector switch for activation
of by-pass contactor.•Ready for installation of dry running
control float or pressure switch (tobe ordered separately).Can be equipped with electronicprotection module with electrodes.
STATIC STARTERCHARACTERISTICS•Static starter for gradual start-
up/shutdown, featuring:keypanel with liquid crystal displayshowing voltage, absorbed current,cos ϕ, operating hours, number ofstarts, last twenty messages onsystem status (events / alarms).Protections against phase failure /phase sequence / frequency out oflimits on power supply line.
Low-voltage protection on auxiliarycircuits.Protection against starterovertemperature / overload /malfunction.Protection against overload / lockedrotor / current asymmetry on motorside.Short-circuit protection on inputs andoutputs.RS232 interface for remote controland RS 485 for use of remotekeypanel.Incorporated by-pass contactor.
OPTIONALACCESSORIES•SLD series 24V level kit.
Probe module for protection againstdry running (set of three electrodesincluded in the supply).
•Float.•Pressure switch.•VR3 three-phase module for
overvoltage protection (lightningprotector).
Q3SF/75 5,5-7,5 7,5-10 8,5-17 400 x 600 x 250 35Q3SF/150 9,2-15 12,5-20 15-30
500 x 700 x 250 40Q3SF/220 18,5-22 25-30 28-45Q3SF/300 30 40 42-60Q3SF/370 37 50 55-75Q3SF/450 45 60 70-85 600 x 900 x 300 90Q3SF/550 55 75 80-110Q3SF/590 59 80 105-125Q3SF/750 75 100 120-142
600 x 1700 x 400Q3SF/900 90 122 135-190
floor120
Q3SF/1100 110 150 185-245
PANEL RATED APPLICATION DIMENSIONS WEIGHT TYPE POWER RANGE A x B x C WITH
PACKINGkW HP A mm kg
Line protection to be provided by the user.
For proper selection, make sure that the ampere input of the electric motor matches the values specified in the table.
52
ACCESSORIES
0 50 0,5050 100 0,75100 200 1,00200 400 2,50400 oltre 4,00
LENGHT CABLE CROSS SECTION
mt mm2
LevelControlPanel
QCL5 Series
APPLICATIONS
• Accessory for electric pump control panels, suitable for tankfilling or drainage applications or for activation of audible orvisual alarms.
SPECIFICATIONS •Automatic control through probes.•Supply voltage: 1 x 230 V ±10% or
1 x 24 V ±10%.•Frequency 50/60 Hz.•Voltage to probes: 15 V AC at 0.5
mA max.•Switch contact: 48 V AC at 3 A max
(250 W max).•Autotransformer start.•Protection class: IP 55.•Ambient temperature: -5 to +40 °C
(limit specified by EN standard60439-1).
•Maximum relative humidity: 50% at+40°C, provided that nocondensation occurs (limit specifiedby EN standard 60439-1).
•Wall mounted.•Electrodes suitable for water at a
maximum temperature of 40°C.•Plastic enclosure.•Set of three electrodes included in
the supply.
OPTIONALACCESSORIES•Drop cable with circular cross
section.
For connection of the electrodes to thepanel we recommend the followingcross sections:
Three-pole cables can be used for shortlengths.Otherwise we recommend the use ofunipolar cables placed at suitabledistances from each other to preventthe capacitive effect of the cable frominterfering with the proper operationof the electronic module.
QCL5/230 1x23050/60 Hz
NO-C-NC 48 V a 3 A 90x130x60 0,5QCL5/24 1x2450/60 Hz
PANEL VOLTAGE OUTPUT CONTACT DIMENSIONS WEIGHTTYPE CONTACTS CAPACITY A x B x C WITH
PACKINGV mm kg
Line protection to be provided by the user.
53
ACCESSORIESLevel ProbeModule
SLD Series
APPLICATIONS
• Accessory for electric panels.
SPECIFICATIONS•Electronic module for use of probes
as protection against dry running.•Supply voltage: 1 x 24 V ±10 % for
model SLD/24.•Frequency: 50/60 Hz.•Absorbed power: 2 VA.•Voltage to probes: 15 V AC at 0.5
mA max.•Switch contact: 24 V AC at 5 A max
(250 W max).•Designed for installation on Lowara
electric panels featuring DIN bar.•Electrodes suitable for water at a
maximum temperature of 40°C.
CONSTRUCTIONCHARACTERISTICS•Module made of plastic material
with DIN bar attachment•Cables with quick plug-in
connectors.•Set of three electrodes included in
the supply.•Electrodes with nylon 6 body,
stainless steel sensitive element,brass washer and nitrile rubber seal.
OPTIONALACCESSORIES•Drop cable with circular cross
section For connection of theelectrodes to the panel werecommend the following crosssections:
0 50 0,5050 100 0,75100 200 1,00200 400 2,50400 oltre 4,00
LENGHT CABLE CROSS SECTION
mt mm2
Three-pole cables can be used forshort lengths.Otherwise we recommend the use ofsingle-pole cables placed at suitabledistancesfrom each other to prevent thecapacitive effect of the cable frominterfering with the proper operationof the electronic module.
TYPE VOLTAGE CONTACT APPLICATIONS DIMENSIONSCAPACITYI A x B x C
V mm
Kit SLD/24 1 x 24 24 V a 5 A50/60 Hz
QMCS-QTDQ3D-Q3Y
90 x 35 x 60Q3A-Q3I
Q3SF
54
ACCESSORIESProtectionagainstlightning
APPLICATIONS
• Accessory for electric panels.
VR SERIESSPECIFICATIONS•Lightning arresters for protection of
three-phase lines.•To be connected between the
phases and earth conductor.•Operating voltage: 460 V AC.•Maximum varistor voltage: 750 V
with 100 A peak current.•Designed for installation on Lowara
electric panels featuring DIN bar.
KIT VR3 3 x 400 QTD - Q3D50/60 Hz
TYPE VOLTAGE APPLICATION
V
SCA3 SERIESSPECIFICATIONS•Lightning arresters for protection of
three-phase lines.To be connected between thephases and earth conductor.
•Operating voltage: 500 VAC.•Max varistor voltage: 2.5 kV with 40
kA peak current.•Designed for assembly on Lowara
electric panels featuring DIN bar.
KIT SCA3 3 x 400 Q3Y - Q3A - Q3I - Q3SF50/60 Hz Q3D
TYPE VOLTAGE APPLICATION
V
55
ACCESSORIES
COOLING SHROUDS
D x L D x L1 D
D225X800 D225X192 D225D225X900 D225X192 D225
D225X1000 D225X192 D225D225X1250 D225X192 D225D225X1500 D225X192 D225D225X1750 D225X192 D225D256X800 D256X325 D256D256X900 D256X325 D256
D256X1000 D256X325 D256D256X1250 D256X325 D256D256X1500 D256X325 D256D256X1750 D256X325 D256D256X1250 D256X325 D256D256X1500 D256X325 D256D256X1750 D256X325 D256D256X2000 D256X325 D256D256X2250 D256X325 D256D285X1250 D285X385 D285D285X1500 D285X385 D285D285X1750 D285X385 D285D285X2000 D285X385 D285D285X2500 D285X385 D285D285X1750 D285X385 D285D330X1750 D330X385 D330D330X2000 D330X385 D330D330X2250 D330X385 D330
som-8_kit-raff_a_td
10"
8"
6"
SLEEVE FILTER SUPPORT
COOLING COOLING COOLING
KIT KIT KITTYPE
56
L6C SERIES MOTORSMOTOR-COOLING SLEEVE COMBINATION TABLE
Z855 01-L6C 1 D225X800 D225X192 D225 2PZZ855 02/2A-L6C 2 D225X800 D225X192 D225 2PZZ855 02/1A-L6C 2 D225X800 D225X192 D225 2PZ
Z855 02-L6C 2 D225X1000 D225X192 D225 2PZZ855 03/2A-L6C 3 D225X1000 D225X192 D225 2PZ
Z855 03-L6C 3 D225X1000 D225X192 D225 2PZZ855 04/2A-L6C 4 D225X1000 D225X192 D225 2PZ
Z855 04-L6C 4 D225X1250 D225X192 D225 2PZZ855 05/3A-L6C 5 D225X1250 D225X192 D225 2PZZ855 05/2A-L6C 5 D225X1250 D225X192 D225 2PZ
Z855 05-L6C 5 D225X1250 D225X192 D225 2PZZ855 06/2A-L6C 6 D225X1750 D225X192 D225 3PZ
Z855 06-L6C 6 D225X1750 D225X192 D225 3PZZ855 07/2A-L6C 7 D225X1750 D225X192 D225 3PZ
Z855 07-L6C 7 D225X1750 D225X192 D225 3PZZ855 08/2A-L6C 8 D225X1750 D225X192 D225 3PZ
Z855 08-L6C 8 D225X1750 D225X192 D225 3PZZ855 09/2A-L6C 9 D225X1750 D225X192 D225 3PZ
Z875 01-L6C 1 D225X800 D225X192 D225 2PZZ875 02/2A-L6C 2 D225X800 D225X192 D225 2PZZ875 02/1A-L6C 2 D225X1000 D225X192 D225 2PZ
Z875 02-L6C 2 D225X1000 D225X192 D225 2PZZ875 03/3A-L6C 3 D225X1000 D225X192 D225 2PZZ875 03/2A-L6C 3 D225X1000 D225X192 D225 2PZZ875 03/1A-L6C 3 D225X1000 D225X192 D225 2PZ
Z875 03-L6C 3 D225X1250 D225X192 D225 2PZZ875 04/2A-L6C 4 D225X1250 D225X192 D225 2PZ
Z875 04-L6C 4 D225X1250 D225X192 D225 2PZZ875 05/3A-L6C 5 D225X1250 D225X192 D225 2PZZ875 05/2A-L6C 5 D225X1750 D225X192 D225 3PZ
Z875 05-L6C 5 D225X1750 D225X192 D225 3PZZ875 06/2A-L6C 6 D225X1750 D225X192 D225 3PZZ875 06/1A-L6C 6 D225X1750 D225X192 D225 3PZ
Z875 06-L6C 6 D225X1750 D225X192 D225 3PZZ875 07/2A-L6C 7 D225X1750 D225X192 D225 3PZ
Z875 07-L6C 7 D225X1750 D225X192 D225 3PZZ875 08/3A-L6C 8 D225X1750 D225X192 D225 3PZ
Z895 01-L6C 1 D256X800 D256X325 D256 2PZZ895 02/2B-L6C 2 D256X1000 D256X325 D256 2PZZ895 02/2A-L6C 2 D256X1000 D256X325 D256 2PZ
Z895 02-L6C 2 D256X1000 D256X325 D256 2PZZ895 03/2B-L6C 3 D256X1250 D256X325 D256 2PZZ895 03/1A-L6C 3 D256X1250 D256X325 D256 2PZ
Z895 03-L6C 3 D256X1750 D256X325 D256 3PZZ895 04/2B-L6C 4 D256X1750 D256X325 D256 3PZZ895 04/2A-L6C 4 D256X1750 D256X325 D256 3PZ
Z895 04-L6C 4 D256X1750 D256X325 D256 3PZZ895 05/3A-L6C 5 D256X1750 D256X325 D256 3PZ
Z895 05-L6C 5 D256X1750 D256X325 D256 3PZZ8125 01-L6C 1 D256X800 D256X325 D256 2PZ
Z8125 02/2B-L6C 2 D256X1000 D256X325 D256 2PZZ8125 02/2A-L6C 2 D256X1000 D256X325 D256 2PZ
Z8125 02-L6C 2 D256X1000 D256X325 D256 2PZZ8125 03/3A-L6C 3 D256X1250 D256X325 D256 2PZ
Z8125 03-L6C 3 D256X1250 D256X325 D256 2PZZ8125 04/2B-L6C 4 D256X1750 D256X325 D256 3PZZ8125 04/2A-L6C 4 D256X1750 D256X325 D256 3PZ
Z8125 04-L6C 4 D256X1750 D256X325 D256 3PZZ8125 05/3A-L6C 5 D256X1750 D256X325 D256 3PZ
Z8125 05-L6C 5 D256X1750 D256X325 D256 3PZZ8125 06/3A-L6C 6 D256X1750 D256X325 D256 3PZ
* Horizontal installation not allowed. The supports must be used for vertical electric pump locking. L6C_camicie-Z8-50_a_ta
L6C
SLEEVE COOLINGKIT
FILTER COOLINGKIT
SUPPORT COOLINGKIT
MOTOR TYPE PUMP TYPE N. OF STAGES
ACCESSORIES
57
F6../316 SERIES MOTORSMOTOR-COOLING SLEEVE COMBINATION TABLE
Z855 01-F6 1 D225X800 D225X192 D225 2PZZ855 02/2A-F6 2 D225X800 D225X192 D225 2PZZ855 02/1A-F6 2 D225X800 D225X192 D225 2PZ
Z855 02-F6 2 D225X800 D225X192 D225 2PZZ855 03/2A-F6 3 D225X1000 D225X192 D225 2PZ
Z855 03-F6 3 D225X1000 D225X192 D225 2PZZ855 04/2A-F6 4 D225X1000 D225X192 D225 2PZ
Z855 04-F6 4 D225X1000 D225X192 D225 2PZZ855 05/3A-F6 5 D225X1000 D225X192 D225 2PZZ855 05/2A-F6 5 D225X1250 D225X192 D225 2PZ
Z855 05-F6 5 D225X1250 D225X192 D225 2PZZ855 06/2A-F6 6 D225X1250 D225X192 D225 2PZ
Z855 06-F6 6 D225X1250 D225X192 D225 2PZZ855 07/2A-F6 7 D225X1250 D225X192 D225 2PZ
Z855 07-F6 7 D225X1250 D225X192 D225 2PZZ855 08/2A-F6 8 D225X1750 D225X192 D225 3PZ
Z855 08-F6 8 D225X1750 D225X192 D225 3PZZ855 09/2A-F6 9 D225X1750 D225X192 D225 3PZ
Z875 01-F6 1 D225X800 D225X192 D225 2PZZ875 02/2A-F6 2 D225X800 D225X192 D225 2PZZ875 02/1A-F6 2 D225X800 D225X192 D225 2PZ
Z875 02-F6 2 D225X1000 D225X192 D225 2PZZ875 03/3A-F6 3 D225X1000 D225X192 D225 2PZZ875 03/2A-F6 3 D225X1000 D225X192 D225 2PZZ875 03/1A-F6 3 D225X1000 D225X192 D225 2PZ
Z875 03-F6 3 D225X1000 D225X192 D225 2PZZ875 04/2A-F6 4 D225X1000 D225X192 D225 2PZ
Z875 04-F6 4 D225X1250 D225X192 D225 2PZZ875 05/3A-F6 5 D225X1250 D225X192 D225 2PZZ875 05/2A-F6 5 D225X1250 D225X192 D225 2PZ
Z875 05-F6 5 D225X1250 D225X192 D225 2PZZ875 06/2A-F6 6 D225X1250 D225X192 D225 2PZZ875 06/1A-F6 6 D225X1250 D225X192 D225 2PZ
Z875 06-F6 6 D225X1750 D225X192 D225 3PZZ875 07/2A-F6 7 D225X1750 D225X192 D225 3PZ
Z875 07-F6 7 D225X1750 D225X192 D225 3PZZ875 08/3A-F6 8 D225X1750 D225X192 D225 3PZ
Z895 01-F6 1 D256X800 D256X325 D256 2PZZ895 02/2B-F6 2 D256X800 D256X325 D256 2PZZ895 02/2A-F6 2 D256X1000 D256X325 D256 2PZ
Z895 02-F6 2 D256X1000 D256X325 D256 2PZZ895 03/2B-F6 3 D256X1000 D256X325 D256 2PZZ895 03/1A-F6 3 D256X1250 D256X325 D256 2PZ
Z895 03-F6 3 D256X1250 D256X325 D256 2PZZ895 04/2B-F6 4 D256X1250 D256X325 D256 2PZZ895 04/2A-F6 4 D256X1250 D256X325 D256 2PZ
Z895 04-F6 4 D256X1250 D256X325 D256 2PZZ895 05/3A-F6 5 D256X1750 D256X325 D256 3PZ
Z895 05-F6 5 D256X1750 D256X325 D256 3PZZ8125 01-F6 1 D256X800 D256X325 D256 2PZ
Z8125 02/2B-F6 2 D256X800 D256X325 D256 2PZZ8125 02/2A-F6 2 D256X1000 D256X325 D256 2PZ
Z8125 02-F6 2 D256X1000 D256X325 D256 2PZZ8125 03/3A-F6 3 D256X1000 D256X325 D256 2PZ
Z8125 03-F6 3 D256X1250 D256X325 D256 2PZZ8125 04/2B-F6 4 D256X1250 D256X325 D256 2PZZ8125 04/2A-F6 4 D256X1250 D256X325 D256 2PZ
Z8125 04-F6 4 D256X1250 D256X325 D256 2PZZ8125 05/3A-F6 5 D256X1750 D256X325 D256 3PZ
Z8125 05-F6 5 D256X1750 D256X325 D256 3PZ* Horizontal installation not allowed. The supports must be used for vertical electric pump locking. F6-316_camicie-Z8-50_a_ta
F6../316
SLEEVE COOLING
KITFILTER COOLING
KITSUPPORT COOLING
KITMOTOR TYPE PUMP TYPE N. OF STAGES
ACCESSORIES
58
MC8 SERIES MOTORSMOTOR-COOLING SLEEVE COMBINATION TABLE
Z855 09-MC8 9 D256X1500 D256X325 D256 3PZZ855 10/2A-MC8 10 D256X1500 D256X325 D256 3PZ
Z855 10-MC8 10 D256X1500 D256X325 D256 3PZZ855 11/2A-MC8 11 D256X1500 D256X325 D256 3PZ
Z855 11-MC8 11 D256X1500 D256X325 D256 3PZZ855 12-MC8 12 D256X1500 D256X325 D256 3PZZ855 13-MC8 13 D256X1750 D256X325 D256 3PZZ855 14-MC8 14 D256X1750 D256X325 D256 3PZZ855 15-MC8 15 D256X1750 D256X325 D256 3PZZ855 16-MC8 16 D256X1750 D256X325 D256 3PZZ855 17-MC8 17 D256X2000 D256X325 D256 3PZZ855 18-MC8 18 D256X2000 D256X325 D256 3PZZ855 19-MC8 19 D256X2000 D256X325 D256 3PZ
Z875 08/2A-MC8 8 D256X1500 D256X325 D256 3PZZ875 08-MC8 8 D256X1500 D256X325 D256 3PZ
Z875 09/2A-MC8 9 D256X1500 D256X325 D256 3PZZ875 09-MC8 9 D256X1500 D256X325 D256 3PZ
Z875 10/2A-MC8 10 D256X1500 D256X325 D256 3PZZ875 10-MC8 10 D256X1500 D256X325 D256 3PZ
Z875 11/2A-MC8 11 D256X1500 D256X325 D256 3PZZ875 11-MC8 11 D256X1750 D256X325 D256 3PZZ875 12-MC8 12 D256X1750 D256X325 D256 3PZZ875 13-MC8 13 D256X1750 D256X325 D256 3PZZ875 14-MC8 14 D256X1750 D256X325 D256 3PZZ875 15-MC8 15 D256X2000 D256X325 D256 3PZZ875 16-MC8 16 D256X2000 D256X325 D256 3PZZ875 17-MC8 17 D256X2000 D256X325 D256 3PZ
Z895 06/3A-MC8 6 D285X1500 D285X385 D285 3PZZ895 06-MC8 6 D285X1500 D285X385 D285 3PZ
Z895 07/3A-MC8 7 D285X1500 D285X385 D285 3PZZ895 07-MC8 7 D285X1500 D285X385 D285 3PZ
Z895 08/3A-MC8 8 D285X1750 D285X385 D285 3PZZ895 08-MC8 8 D285X1750 D285X385 D285 3PZ
Z895 09/3A-MC8 9 D285X1750 D285X385 D285 3PZZ895 09-FW8 9 D285X1750 D285X385 D285 3PZ
Z895 10/3A-MC8 10 D285X1750 D285X385 D285 3PZZ895 10-MC8 10 D285X1750 D285X385 D285 3PZZ895 11-MC8 11 D285X2000 D285X385 D285 3PZZ895 12-MC8 12 D285X2000 D285X385 D285 3PZ
Z8125 06/3A-MC8 6 D285X1500 D285X385 D285 3PZZ8125 06-MC8 6 D285X1500 D285X385 D285 3PZ
Z8125 07/3A-MC8 7 D285X1500 D285X385 D285 3PZZ8125 07-MC8 7 D285X1500 D285X385 D285 3PZ
Z8125 08/3A-MC8 8 D285X1500 D285X385 D285 3PZZ8125 08-MC8 8 D285X1750 D285X385 D285 3PZ
Z8125 09/3A-MC8 9 D285X1750 D285X385 D285 3PZZ8125 09-MC8 9 D285X1750 D285X385 D285 3PZ
Z8125 10/3A-MC8 10 D285X1750 D285X385 D285 3PZZ8125 10-MC8 10 D285X1750 D285X385 D285 3PZZ8125 11-MC8 11 D285X2000 D285X385 D285 3PZZ8125 12-MC8 12 D285X2000 D285X385 D285 3PZ
* Horizontal installation not allowed. The supports must be used for vertical electric pump locking. MC8_camicie-Z8-50_a_ta
MC8
SLEEVE COOLINGKIT
FILTER COOLINGKIT
SUPPORT COOLINGKIT
MOTOR TYPE PUMP TYPE N. OF STAGES
ACCESSORIES
Z855 09-FW8 9 D256X1500 D256X325 D256 3PZZ855 10/2A-FW8 10 D256X1500 D256X325 D256 3PZ
Z855 10-FW8 10 D256X1500 D256X325 D256 3PZZ855 11/2A-FW8 11 D256X1500 D256X325 D256 3PZ
Z855 11-FW8 11 D256X1500 D256X325 D256 3PZZ855 12-FW8 12 D256X1500 D256X325 D256 3PZZ855 13-FW8 13 D256X1750 D256X325 D256 3PZZ855 14-FW8 14 D256X1750 D256X325 D256 3PZZ855 15-FW8 15 D256X1750 D256X325 D256 3PZZ855 16-FW8 16 D256X1750 D256X325 D256 3PZZ855 17-FW8 17 D256X2000 D256X325 D256 3PZZ855 18-FW8 18 D256X2000 D256X325 D256 3PZZ855 19-FW8 19 D256X2000 D256X325 D256 3PZ
Z875 08/2A-FW8 8 D256X1500 D256X325 D256 3PZZ875 08-FW8 8 D256X1500 D256X325 D256 3PZ
Z875 09/2A-FW8 9 D256X1500 D256X325 D256 3PZZ875 09-FW8 9 D256X1500 D256X325 D256 3PZ
Z875 10/2A-FW8 10 D256X1500 D256X325 D256 3PZZ875 10-FW8 10 D256X1500 D256X325 D256 3PZ
Z875 11/2A-FW8 11 D256X1500 D256X325 D256 3PZZ875 11-FW8 11 D256X1750 D256X325 D256 3PZZ875 12-FW8 12 D256X1750 D256X325 D256 3PZZ875 13-FW8 13 D256X1750 D256X325 D256 3PZZ875 14-FW8 14 D256X1750 D256X325 D256 3PZZ875 15-FW8 15 D256X2000 D256X325 D256 3PZZ875 16-FW8 16 D256X2000 D256X325 D256 3PZZ875 17-FW8 17 D256X2000 D256X325 D256 3PZ
Z895 06/3A-FW8 6 D285X1500 D285X385 D285 3PZZ895 06-FW8 6 D285X1500 D285X385 D285 3PZ
Z895 07/3A-FW8 7 D285X1500 D285X385 D285 3PZZ895 07-FW8 7 D285X1500 D285X385 D285 3PZ
Z895 08/3A-FW8 8 D285X1750 D285X385 D285 3PZZ895 08-FW8 8 D285X1750 D285X385 D285 3PZ
Z895 09/3A-FW8 9 D285X1750 D285X385 D285 3PZZ895 09-FW8 9 D285X1750 D285X385 D285 3PZ
Z895 10/3A-FW8 10 D285X1750 D285X385 D285 3PZZ895 10-FW8 10 D285X1750 D285X385 D285 3PZZ895 11-FW8 11 D285X2000 D285X385 D285 3PZZ895 12-FW8 12 D285X2000 D285X385 D285 3PZ
Z8125 06/3A-FW8 6 D285X1500 D285X385 D285 3PZZ8125 06-FW8 6 D285X1500 D285X385 D285 3PZ
Z8125 07/3A-FW8 7 D285X1500 D285X385 D285 3PZZ8125 07-FW8 7 D285X1500 D285X385 D285 3PZ
Z8125 08/3A-FW8 8 D285X1500 D285X385 D285 3PZZ8125 08-FW8 8 D285X1750 D285X385 D285 3PZ
Z8125 09/3A-FW8 9 D285X1750 D285X385 D285 3PZZ8125 09-FW8 9 D285X1750 D285X385 D285 3PZ
Z8125 10/3A-FW8 10 D285X1750 D285X385 D285 3PZZ8125 10-FW8 10 D285X1750 D285X385 D285 3PZZ8125 11-FW8 11 D285X2000 D285X385 D285 3PZZ8125 12-FW8 12 D285X2000 D285X385 D285 3PZ
* Horizontal installation not allowed. The supports must be used for vertical electric pump locking. FW8_camicie-Z8-50_a_ta
FW8
SLEEVE COOLINGKIT
FILTER COOLINGKIT
SUPPORT COOLINGKIT
MOTOR TYPE PUMP TYPE N. OF STAGES
59
FW8 SERIES MOTORSMOTOR-COOLING SLEEVE COMBINATION TABLE
ACCESSORIES
60
MC10 SERIES MOTORSMOTOR-COOLING SLEEVE COMBINATION TABLE
FW10 SERIES MOTORSMOTOR-COOLING SLEEVE COMBINATION TABLE
Z875 18-MC10 18 D285X1750 D285X385 D285 3PZZ895 13-MC10 13 D330X2000 D330X385 D330 3PZZ895 14-MC10 14 D330X2000 D330X385 D330 3PZZ895 15-MC10 15 D330X2250 D330X385 D330 3PZZ895 16-MC10 16 D330X2250 D330X385 D330 3PZZ895 17-MC10 17 D330X2250 D330X385 D330 3PZZ895 18-MC10 18 D330X2250 D330X385 D330 3PZ
Z8125 13-MC10 13 D330X2000 D330X385 D330 3PZZ8125 14-MC10 14 D330X2000 D330X385 D330 3PZZ8125 15-MC10 15 D330X2000 D330X385 D330 3PZZ8125 16-MC10 16 D330X2250 D330X385 D330 3PZZ8125 17-MC10 17 D330X2250 D330X385 D330 3PZZ8125 18-MC10 18 D330X2250 D330X385 D330 3PZ
* Horizontal installation not allowed. The supports must be used for vertical electric pump locking. MC10_camicie-Z8-50_a_ta
MC10
SLEEVE COOLINGKIT
FILTER COOLINGKIT
SUPPORT COOLINGKIT
MOTOR TYPE PUMP TYPE N. OF STAGES
Z875 18-FW10 18 D285X1750 D285X385 D285 3PZZ895 13-FW10 13 D330X1750 D330X385 D330 3PZZ895 14-FW10 14 D330X1750 D330X385 D330 3PZZ895 15-FW10 15 D330X2000 D330X385 D330 3PZZ895 16-FW10 16 D330X2000 D330X385 D330 3PZZ895 17-FW10 17 D330X2000 D330X385 D330 3PZZ895 18-FW10 18 D330X2000 D330X385 D330 3PZ
Z8125 13-FW10 13 D330X1750 D330X385 D330 3PZZ8125 14-FW10 14 D330X1750 D330X385 D330 3PZZ8125 15-FW10 15 D330X1750 D330X385 D330 3PZZ8125 16-FW10 16 D330X2000 D330X385 D330 3PZZ8125 17-FW10 17 D330X2000 D330X385 D330 3PZZ8125 18-FW10 18 D330X2000 D330X385 D330 3PZ
* Horizontal installation not allowed. The supports must be used for vertical electric pump locking. FW10_camicie-Z8-50_a_ta
FW10
SLEEVE COOLINGKIT
FILTER COOLINGKIT
SUPPORT COOLINGKIT
MOTOR TYPE PUMP TYPE N. OF STAGES
ACCESSORIES
61
TECHNICALAPPENDIX
TECHNICAL APPENDIX
62
SUBMERSIBLE ELECTRIC PUMP INSTALLATION DIAGRAM
COMPONENTS REQUIRED FORCORRECT INSTALLATION• Control panel equipped with a main switch and thermal
relay for overload protection• Non-return valve at 10 meters’ distance from the
delivery port, plus an additional non-return valve every30÷50 meters of piping
• Gauge and gate valve at well mouth• Electronic probes or floats for protection against dry
running
RECOMMENDATIONS• Secure the drop cable to the pipe every 3÷6 meters of
piping• Make sure the electric pump is installed at a safe
distance from the bottom of the well• Make sure there is a minimum distance of 3 mm
between the diameter of the pump and the internaldiameter of the well
• During operation, make sure that the water circulationspeed around the motor is at least 8 cm/sec
• Make sure that the minimum dynamic level of the waterin the well is at least 1 m above the pump’s deliveryport
1 - Submersible electric pump2 - Delivery pipe3 - Drop cable4 - Control panel5 - Non-return valve6 - Gauge7 - On\off valve8 - Level sensors for protection
against dry running9 - Cable clamp
10 - Electric pumpbleed/priming cap
A - Distance between theclamps that secure the dropcable to the delivery pipe
B - Distance from the bottomof the well to the electricpump
TECHNICAL APPENDIX
63
EXAMPLE OF INSTALLATION OF A SUBMERSIBLE ELECTRICPUMP CONTROLLED BY AN INVERTER (HYDROVAR®)
1 - Submersible electric pump2 - Cable clamp3 - Motor supply electrical cable4 - Level sensors for protection against
dry running5 - Support bracket6 - Check valve7 - Gauge8 - Pressure transducer9 - Gate valve
10 - Diaphragm tank11 - QLC5 level probe control panel12 - QHI motor filter panel, required for
cable lengths exceeding 20 meters13 –Hydrovar® (inverter)14 - Thermal magnetic circuit breaker (QHV)15 - Delivery pipe16 - Electric pump bleed/priming cap
N.B. For correct Inverter-Motor coupling,contact our sales network
MC8 – MC10 – MC12 MOTORSTABLE OF POWER REDUCTION COEFFICIENTS WITH INCREASED WATER TEMPERATURE
MOTOR RATED TEMPERATURE
TYPE POWER °C
kW 25 30 35 40 45 50 55 60
MC8 (1) all models 1 0,85 0,74 - - - - -
MC8 (2) all models 1 1 1 1 1 0,85 0,75 0,67
MC10 (1) all models 1 0,85 0,74 - - - - -
MC10 (2) all models 1 1 1 1 1 0,85 0,75 0,67
MC12 (1) all models 1 0,85 0,74 - - - - -
MC12 (2) all models 1 1 1 1 1 0,85 0,75 0,67
(1) Standard windings for water temperature up to 35°C. MC-derating-50_a_te
(2) Special windings for water temperature up to 35 °C to 60 °C.
EXAMPLE:An MC8-75, 55 kW motor must work in water at a temperature of 35°C.Motor power at 35°C = 55 x 0.74 = 40.7 kW
64
TECHNICAL APPENDIX
F6 – F6../316 - F8 MOTORSTABLE OF POWER INCREASE COEFFICIENTS WITH INCREASED WATER TEMPERATURE
L6C MOTORSTABLE OF POWER INCREASE COEFFICIENTS WITH INCREASED WATER TEMPERATURE
(A) Multiply the pump power required bythe increase coefficient from the table.
(B) Select a motor on table whose power isequal or greater than the calculated value.
EXAMPLE:A Z855 06-F6 pump must pump water at a temperature of 50°C.The power input can be determined from the diagram relating to the pump.Pa = Power per stage x no. of stages = 4.6 x 6 = 27.6 kWThe pump requires a 30 kW motor.Power requirement at 50°C = 30 x 1.32 = 39.6 kW
MOTOR RATED TEMPERATURE
TYPE POWER °C
kW 25 30 35 40 45 50 55 60
F6 (1) da 5.5 a 22 1 1 1 1 1 1,14 1,32 1,62
F6, F8 (1) sopra a 22 1 1 1 1 1,14 1,32 1,62 2
(1) Vmin water = 0.91 m/s F6-F8-derating-50_a_te
MOTOR RATED TEMPERATURE
TYPE POWER °C
kW 35 40 45 50 55 60
L6C all models 1 0,95 0,8 0,75 0,7 0,6
L6c-derating-50_b_te
EXAMPLE:An L6C, 7.5 kW motor must work in water at a temperature of 45°C.Motor power at 50°C = 7.5 x 0.8 = 6 kW
TECHNICAL APPENDIX
65
MOTOR RATED TEMPERATURE
TYPE POWER °C
kW 25 30 35 40 45 50 55 60 65
FW8 (1) da 30 a 52 1 1 0,93 0,83 0,72 - - - -
FW8 (2) da 30 a 52 1 1 1 1 1 1 0,93 0,83 0,72
FW8 (3) da 55 a 93 1 1 0,92 0,82 0,68 - - - -
FW8 (4) da 55 a 93 1 1 1 1 1 1 0,92 0,82 0,68
FW10 (5) all models 1 0,93 0,83 0,71 - - - - -
FW10 (6) all models 1 1 1 1 1 0,93 0,83 0,71 -
FW8-FW10-derating-50_a_te
(1) Vmin water = 0.2 m/s. Standard windings for water temperature up to 45 °C.
(2) Vmin water = 0.2 m/s. Special windings for water temperature up to 65 °C.
(3) Vmin water = 0.5 m/s. Standard windings for water temperature up to 45 °C.
(4) Vmin water = 0.5 m/s. Special windings for water temperature up to 65 °C.
(5) Vmin water = 0.5 m/s. Standard windings for water temperature up to 40 °C.
(6) Vmin water = 0.5 m/s. Special windings for water temperature up to 60 °C.
FW8 – FW10 MOTORSTABLE OF POWER REDUCTION COEFFICIENTS WITH INCREASED WATER TEMPERATURE
EXAMPLE:An FW845T405, 45 kW motor must work in water at a temperature of 40°C.Motor power at 40°C = 45 x 0.83 = 37.4 kW
66
TECHNICAL APPENDIX
DETERMINING THE CABLE SECTION REQUIRED FORLOW-VOLTAGE SUBMERSIBLE MOTORS
The section required depends on the maximum admissible load current - which determines the heating factor - onthe ambient temperature and how the cable is laid.Voltage loss, and therefore loss of cable efficiency, constitutes the decisive selection criterium for long cables.
The required cable section is calculated based on the following formulas:
Direct start: q = Star – Delta start q =
q... cable section in mm2 l... Cable length in mm
l... rated motor current in A cos�... Power factor of submersible motorX... Electrical conductivity (53 for copper) U... Rated voltage∆u Voltage drop in %
When sizing the cable section, keep in mind that higher voltage drops mean increased power losses andconsequently higher operating costs.
The diagrams show how the required cable section is calculated based on a voltage rating of 400V and a power
factor cos�=0,85 and 3% voltage drop, , at an ambient temperature of 30°C. If the temperature is higher than30°C, the maximum admissible current carrying capacity of the cable at the actual ambient temperature must betaken into account (see table next to diagrams).The inductive voltage drop is negligible and has not been taken into account, therefore these diagrams can beadopted regardless of the frequency.The current carrying capacity can be established from the horizontal lines above the length of the cable (verticallines). The bend point indicates the limit length for 3% voltage drops.
Examples:
1.) Star-Delta start:Calculate the cable section Waterproof cableRated motor current: 85 A Length of cable: 35 m
On the horizontal axis, follow the 85 A rated current until you reach a conductivity section with which thelength of the cable is greater than or equal to 35m. In this case, 6 mm2. The maximum length for a 3% voltagedrop is 43 m. Therefore, in this case the voltage drop is 3x35/46=2.3%
2.) the same data, but with 50°C ambient temperature:The table next to the diagram shows that the maximum current carrying capacity of a 6 mm2 cable at 50°C is78 A, therefore a section of 10 mm2 must be selected. The maximum length for a 3% voltage drop is 76 m.Therefore, in this case the voltage drop is 3x35/76=1.4%
3.) the same data, but with 500V voltage:In order to use the diagrams, the rated current of the motor must be converted in proportion to the voltage:
Current reading = 400V x rated current Current reading = 400V x 85 = 68 Arated voltage 500V
The maximum length for a 3% voltage drop is 38 m. Therefore, the voltage drop is: 3x35/38=2.75%
√3·l·l·cos�·100 x·∆u·U
2·l·l·cos�·100 √3·x·∆u·U
67
SIZING OF CHLOROPRENE RUBBER (CR) H07RN-F CABLESDIRECT-ON-LINE START
Temperature 10°C 15°C 20°C 25°C 30°C 35°C 40°C 45°C 50°C 55°C 60°CSection (mm2)
1,5 21 20 19 18 17 16 15 13 12 - -2,5 29 28 26 25 24 22 20 19 17 - -4 39 37 35 34 32 29 27 25 22 - -6 50 48 46 43 41 38 35 32 29 - -
10 69 66 63 61 57 53 49 45 40 - -16 92 89 85 81 76 70 66 60 54 - -25 123 118 113 108 101 94 88 80 71 - -35 152 146 140 133 125 116 108 98 88 - -50 184 176 169 161 151 140 131 119 107 - -70 234 224 215 205 192 178 167 151 136 - -95 283 271 259 248 232 215 201 183 164 - -
120 328 314 301 287 269 250 234 212 191 - -400 V - 3 % voltage drop - 30 °C ambient temperature - cos ϕ = 0,85 dim-cavi_d-h07_b_te
Max current - (A)
Not suitable for permanent immersion in water.
TECHNICAL APPENDIX
68
TECHNICAL APPENDIX
SIZING OF CHLOROPRENE RUBBER (CR) H07RN-F CABLESSTAR-DELTA START
Temperature 10°C 15°C 20°C 25°C 30°C 35°C 40°C 45°C 50°C 55°C 60°CSection (mm2)
1,5 37 35 34 32 30 28 26 24 21 - -2,5 50 48 46 44 41 38 36 32 29 - -4 67 64 62 59 55 51 48 43 39 - -6 86 83 79 76 71 66 61 56 50 - -
10 120 115 110 105 98 91 86 78 70 - -16 160 154 147 140 131 122 114 104 93 - -25 213 204 195 187 175 162 152 138 124 - -35 264 253 242 231 216 201 188 171 153 - -50 319 306 293 279 261 243 227 206 185 - -70 405 389 372 355 332 309 289 262 263 - -95 490 470 450 429 401 373 349 317 285 - -
120 568 545 521 498 465 433 405 368 330 - -400 V - 3 % voltage drop - 30 °C ambient temperature - cos ϕ = 0,85 dim-cavi_sd-h07_b_te
Max current - (A)
Not suitable for permanent immersion in water.
69
TECHNICAL APPENDIX
SIZING OF ETHYLENE-PROPYLENE RUBBER (EPR) CABLESDIRECT-ON-LINE START
Temperature 10°C 15°C 20°C 25°C 30°C 35°C 40°C 45°C 50°C 55°C 60°CSection (mm2)
1,5 27 26 25 24 24 23 21 20 19 18 152,5 36 35 33 33 32 30 29 27 26 24 204 49 48 45 44 43 41 39 37 35 32 276 64 62 59 58 56 53 50 48 45 42 36
10 89 87 82 81 78 74 70 67 63 59 5016 119 116 110 108 104 99 94 90 85 79 6725 158 154 146 143 138 132 125 120 113 104 8935 196 191 181 177 171 164 155 148 140 129 11150 244 238 225 221 213 204 193 185 174 164 13870 302 294 278 273 263 252 239 228 215 199 17095 346 337 319 313 301 288 273 261 246 228 195
120 404 394 373 366 352 337 320 306 288 267 228400 V - 3 % voltage drop - 30 °C ambient temperature - cos ϕ = 0,85 dim-cavi_d-epr_b_te
Max current - (A)
70
SIZING OF ETHYLENE-PROPYLENE RUBBER (EPR) CABLESSTAR-DELTA START
Temperature 10°C 15°C 20°C 25°C 30°C 35°C 40°C 45°C 50°C 55°C 60°CSection (mm2)
1,5 47 45 43 42 41 39 37 35 33 31 362,5 63 61 58 57 55 52 50 47 45 41 354 85 82 78 76 74 71 67 64 60 56 486 110 107 101 99 96 92 87 83 78 72 62
10 155 151 143 140 135 129 122 117 110 102 8716 207 201 190 187 180 172 163 156 147 136 11725 274 267 253 248 239 229 217 207 195 181 15535 340 331 313 307 296 284 269 257 242 224 19250 423 412 390 382 368 353 334 320 301 279 23970 523 509 482 473 455 436 414 395 373 345 29595 599 583 522 541 521 500 474 453 427 395 338
120 700 682 645 633 609 584 554 529 499 462 395400 V - 3 % voltage drop - 30 °C ambient temperature - cos ϕ = 0,85 dim-cavi_sd-epr_b_te
Max current - (A)
TECHNICAL APPENDIX
TECHNICAL APPENDIX
71
CALCULATING THE SPEED OF THE FLUID THAT FLOWSAROUND A SUBMERGED MOTOR AND SIZING OF THECOOLING SLEEVE
The following formula is used to verify whether the speed of the fluid that flows around the motor of a submersible pump ishigh enough to guarantee the proper cooling of the motor:
Where: Q in [m3/s] is the operating flow rate of the electric pump; only half of this flow is taken into account, because the fluid,which is sucked into the area of the filter (2), comes from the motor side (3) as well as from the pump side (1);D in [m] corresponds to the diameter of the well;d in [m] corresponds to the diameter of the motor (3);v in [m/s] is the calculated speed of the fluid that flows around the motor.
Now, compare the speed thus calculated (v) with the minimum speed required for correct cooling of the motor (vm): if v > vmit means that the motor is properly cooled, if v < vm will be necessary to mount a cooling sleeve (4).
Example:An electric pump OZ630/12 (motor diameter d = 0.144m) operates in an 8” well (well diameter D = 0.203 m) with flow rateQ = 20 m3/h = 0.0055 m3/s.Speed of fluid v = (0.0055/2) / {π·[(0.203)2/4-(0.144)2/4]} = 0.17 m/s.The minimum speed required for proper motor cooling is vm=0.20 m/s.Because v < vm, it will be necessary to mount a cooling sleeve.
––––––––––The following formula is used to determine the maximum diameter of a cooling sleeve to be mounted on a submersiblemotor:
Where: Q in [m3/s] is the operating flow rate of the electric pump; the entire flow is taken into account because the fluid comesfrom the motor side (3) onlyD in [m] corresponds to the diameter of the cooling sleeve (4);d in [m] corresponds to the diameter of the motor (3)vm in [m/s] is the minimum speed of the fluid that flows around the motor.
If the electric pump operates at different flow rates, the minimum flow rate must be taken into account for calculating thediameter of the cooling sleeve
Example:A motor coupled to the electric pump OZ615/24 (motor diameter d = 0.144 m), which operates with flow rate Q=15 m3/h =0.0042m3/s, requires a minimum speed of the fluid of vm=0.20 m/s.Cooling sleeve diameter D = {4·[(0.0042/(0.2·π)+(0.144)2/4]}0.5=0.217 m.
72
DirectSuitable for low-power motors.The starting current (Ia) is much higher than the ratedcurrent (In).Starting current Ia = In x 4 - 8Starting torque Ca = Cn x 2 - 3
Indirect
• Star/DeltaThe starting current (Ia) is three times less than the directstarting current.Starting current Ia = In x 1.3 - 2.7Starting torque Ca = Cn x 0.7 - 1In the star to delta changeover phase (approx. 70 ms) themotor is not supplied and tends to reduce its rotationspeed. In the case of submersible electric pumps with powerabove 10 HP, the modest mass of the rotor causes aslowdown at changeover, so that the initial Star supplyphase is rendered partially useless.In such cases we recommend using impedance panels oran autotransformer.
• Impedances
The motor is started with a voltage which is lower thanthe rated one, and which is obtained by means ofimpedances.The Lowara panels use impedances which cut down to70% the starting voltage.The switch to the rated voltage takes place without anyinterruptions of the power supply.
Rated voltage Vn = 380 VStarting voltage Va = Vn x 0,7 = 266 V
VaIa = In x 4÷8 x = In x 3÷6
VnStarting voltageStarting torque
VaCa = Cn x 2÷3 x
2
= Cn x 1÷1,5Vn
DIAGRAM OF STARTING INPUTS
1 = Direct SPEED’2 = Star-Delta3 = Impedances4 = Autotransformer
Autotransformer
The pump is started with a voltage which is lower thanthe rated one.The Lowara panels use an autotransformer with a voltagethat is 70% the value of the line voltage.The switch to the rated voltage occurs without anyinterruptions of the power supply.Rated voltage Vn = 380 V
Starting currentVa
Ia = In x 4÷8 x = In x 3÷6Vn
Atarting torqueVa
Ca = Cn x 2÷3 x 2
= Cn x 1÷1,5Vn
(
(
)
)
((
))
ASYNCHRONOUS MOTOR STARTING SYSTEMS
Ia
TECHNICAL APPENDIX
73
TECHNICAL APPENDIX
WATER REQUIREMENTS IN CIVIL USERS
Determination of the water requirement depends on the type of users and contemporaneity factor. The calculationmay be subject to regulations, standards or customs that may vary from country to country. The calculation methodshown below is an example based on practical experience, designed to provide a reference value and not a substi-tute for detailed analytical calculation.
Water requirements in condominiums
The consumption table shows the maximum values for each delivery point, depending on the plumbing amenities.
MAXIMUM CONSUMPTION FOR EACH DELIVERY POINT
TYPE CONSUMPTION (l/min)
Sink 9Dishwasher 10Washing machine 12Shower 12Bathtub 15Washbasin 6Bidet 6Flush tank WC 6Controlled flushing system WC 90
G-at-cm_a_th
The sum of the water consumption values of each delivery point determines the maximum theoreticalrequirement, which must be reduced according to the contemporaneity coefficient, because in actual factthe delivery points are never used all together.
The table of water requirements in civil users shows the maximum contemporaneity flow-rate valuesbased on the number of apartments and the type of WC for apartments with one bathroom and two bath-rooms. As regards apartments with one bathroom, 7 drawing points have been taken into consideration, while 11points have been considered for apartments with two bathrooms. If the number of drawing points or apartments isdifferent, use the formulas to calculate the requirement.
( )NaNr857,0
1f
xx
=
( )NaNr857,0
1f
xx
=
( )NaNr545,0
03,1f
xx
=
( )NaNr727,0
8,0f
xx
=
Coefficient for apartments with one bathroom and flush tank WC
Coefficient for apartments with one bathroom and controlled flushing system WC
Coefficient for apartments with two bathrooms and flush tank WC
Coefficient for apartments with two bathrooms and controlled flushing system WC
f= coefficient; Nr= number of delivery points; Na= number of apartments
74
TECHNICAL APPENDIX
NUMBER OF
APARTMENTS 1 2 1 2
1 32 40 60 792 45 56 85 1113 55 68 105 1364 63 79 121 1575 71 88 135 1766 78 97 148 1937 84 105 160 2088 90 112 171 2239 95 119 181 236
10 100 125 191 24911 105 131 200 26112 110 137 209 27313 114 143 218 28414 119 148 226 29515 123 153 234 30516 127 158 242 31517 131 163 249 32518 134 168 256 33419 138 172 263 34320 142 177 270 35221 145 181 277 36122 149 185 283 36923 152 190 290 37824 155 194 296 38625 158 198 302 39426 162 202 308 40127 165 205 314 40928 168 209 320 41729 171 213 325 42430 174 217 331 43135 187 234 357 46640 200 250 382 49845 213 265 405 52850 224 280 427 55755 235 293 448 58460 245 306 468 61065 255 319 487 63570 265 331 506 65975 274 342 523 68280 283 354 540 70485 292 364 557 72690 301 375 573 74795 309 385 589 767
100 317 395 604 787120 347 433 662 863140 375 468 715 932160 401 500 764 996180 425 530 811 1056200 448 559 854 1114
For seaside resorts, a flow rate increased by at least 20% must be considered. G-at-fi_a_th
FLOW RATE (l/min)
WITH FLUSH TANK WC WITH CONTROLLED FLUSHING SYSTEM WC
TABLE OF WATER REQUIREMENTS IN CIVIL USERS
75
TECHNICAL APPENDIX
WATER REQUIREMENTS FOR COMMUNITY BUILDINGS
For seaside resorts, the flow rate must be increased by at least 20%.
1= Offices (N. of people)2= Department stores (N. of people)3= Nursing homes (N. of beds)4= Hotels, residences (N. of beds)
The requirements of buildings intended for specific uses, such as offices, residential units, hotels, depart-ment stores, nursing homes and so on, are different from those of condominiums, and both their globaldaily water consumption and the maximum contemporaneity flow rate are usually greater. The diagram ofwater requirements for community buildings shows the maximum contemporaneity flow rate of sometypes of communities, for guidance.These requirements must be determined case by case with the utmost accuracy, using analytical calculation methods,according to particular needs and local provisions.
76
TECHNICAL APPENDIX
NPSH
The minimum operating values that can be reached atthe pump suction end are limited by the onset ofcavitation.
Cavitation is the formation of vapour-filled cavitieswithin liquids where the pressure is locally reduced to acritical value, or where the local pressure is equal to, orjust below the vapour pressure of the liquid.
The vapour-filled cavities flow with the current andwhen they reach a higher pressure area the vapourcontained in the cavities condenses. The cavities collide,generating pressure waves that are transmitted to thewalls. These, being subjected to stress cycles, graduallybecome deformed and yield due to fatigue. Thisphenomenon, characterized by a metallic noiseproduced by the hammering on the pipe walls, is calledincipient cavitation.
The damage caused by cavitation may be magnified byelectrochemical corrosion and a local rise intemperature due to the plastic deformation of thewalls. The materials that offer the highest resistance toheat and corrosion are alloy steels, especially austeniticsteel. The conditions that trigger cavitation may beassessed by calculating the total net suction head,referred to in technical literature with the acronymNPSH (Net Positive Suction Head).
The NPSH represents the total energy (expressed in m.)of the liquid measured at suction under conditions ofincipient cavitation, excluding the vapour pressure(expressed in m.) that the liquid has at the pump inlet.
To find the static height hz at which to install themachine under safe conditions, the following formulamust be verified:
hp + hz ≥ (NPSHr + 0.5) + hf + hpv ➀
where:hp is the absolute pressure applied to the free liquid
surface in the suction tank, expressed in m. ofliquid; hp is the quotient between the barometricpressure and the specific weight of the liquid.
hz is the suction lift between the pump axis and thefree liquid surface in the suction tank, expressedin m.; hz is negative when the liquid level islower than the pump axis.
hf is the flow resistance in the suction line and itsaccessories, such as: fittings, foot valve, gatevalve, elbows, etc.
hpv is the vapour pressure of the liquid at theoperating temperature, expressed in m. of liquid. hpv is the quotient between the Pv vapourpressure and the liquid's specific weight.
0.5 is the safety factor.
The maximum possible suction head for installationdepends on the value of the atmospheric pressure(i.e. the elevation above sea level at which the pumpis installed) and the temperature of the liquid.
To help the user, with reference to water temperature(4°C) and to the elevation above sea level, thefollowing tables show the drop in hydraulic pressurehead in relation to the elevation above sea level, andthe suction loss in relation to temperature.
Water20 40 60 80 90 110 120temperature (°C)
Suction0,2 0,7 2,0 5,0 7,4 15,4 21,5loss (m)
Elevation above500 1000 1500 2000 25003000sea level (m)
Suction0,55 1,1 1,65 2,2 2,75 3,3loss (m)
Flow resistance is shown in the tables at pages 78-79of this catalogue. To reduce it to a minimum,especially in cases of high suction head (over 4-5 m.)or within the operating limits with high flow rates, werecommend using a suction line having a largerdiameter than that of the pump's suction port.It is always a good idea to position the pump as closeas possible to the liquid to be pumped.
Make the following calculation:
Liquid: water at ∼ 15°C y = 1 kg/dm3
Flow rate required: 30 m3/hHead for required delivery: 43 m.Suction lift: 3.5 m.The selection is an FHE 40-200/75 pump whose NPSHrequired value is, at 30 m3/h, 2.5 m.
For water at 15°C the hpv term is Pv = 0,174 m (0.01701 bar)γ
and hp = Pa = 10,33mγ
The Hf flow resistance in the suction line with footvalves is ∼1.2 m.By substituting the parameters in formula ➀ with thenumeric values above, we have:
10,33 + (-3,5) ≥ (2,5 + 0,5) + 1,2 + 0,17
from which we have: 6.8 > 4.4
The relation is therefore verified.
77
TECHNICAL APPENDIX
t T ps ρ ρ ρt T ps t T ps
°C K bar kg/dm3 °C K bar kg/dm3 °C K bar kg/dm3
0 273,15 0,00611 0,9998 55 328,15 0,15741 0,9857 120 393,15 1,9854 0,94291 274,15 0,00657 0,9999 56 329,15 0,16511 0,9852 122 395,15 2,1145 0,94122 275,15 0,00706 0,9999 57 330,15 0,17313 0,9846 124 397,15 2,2504 0,93963 276,15 0,00758 0,9999 58 331,15 0,18147 0,9842 126 399,15 2,3933 0,93794 277,15 0,00813 1,0000 59 332,15 0,19016 0,9837 128 401,15 2,5435 0,93625 278,15 0,00872 1,0000 60 333,15 0,1992 0,9832 130 403,15 2,7013 0,93466 279,15 0,00935 1,0000 61 334,15 0,2086 0,9826 132 405,15 2,867 0,93287 280,15 0,01001 0,9999 62 335,15 0,2184 0,9821 134 407,15 3,041 0,93118 281,15 0,01072 0,9999 63 336,15 0,2286 0,9816 136 409,15 3,223 0,92949 282,15 0,01147 0,9998 64 337,15 0,2391 0,9811 138 411,15 3,414 0,9276
10 283,15 0,01227 0,9997 65 338,15 0,2501 0,9805 140 413,15 3,614 0,925811 284,15 0,01312 0,9997 66 339,15 0,2615 0,9799 145 418,15 4,155 0,921412 285,15 0,01401 0,9996 67 340,15 0,2733 0,9793 155 428,15 5,433 0,912113 286,15 0,01497 0,9994 68 341,15 0,2856 0,9788 160 433,15 6,181 0,907314 287,15 0,01597 0,9993 69 342,15 0,2984 0,9782 165 438,15 7,008 0,902415 288,15 0,01704 0,9992 70 343,15 0,3116 0,9777 170 433,15 7,920 0,897316 289,15 0,01817 0,9990 71 344,15 0,3253 0,9770 175 448,15 8,924 0,892117 290,15 0,01936 0,9988 72 345,15 0,3396 0,9765 180 453,15 10,027 0,886918 291,15 0,02062 0,9987 73 346,15 0,3543 0,9760 185 458,15 11,233 0,881519 292,15 0,02196 0,9985 74 347,15 0,3696 0,9753 190 463,15 12,551 0,876020 293,15 0,02337 0,9983 75 348,15 0,3855 0,9748 195 468,15 13,987 0,870421 294,15 0,24850 0,9981 76 349,15 0,4019 0,9741 200 473,15 15,550 0,864722 295,15 0,02642 0,9978 77 350,15 0,4189 0,9735 205 478,15 17,243 0,858823 296,15 0,02808 0,9976 78 351,15 0,4365 0,9729 210 483,15 19,077 0,852824 297,15 0,02982 0,9974 79 352,15 0,4547 0,9723 215 488,15 21,060 0,846725 298,15 0,03166 0,9971 80 353,15 0,4736 0,9716 220 493,15 23,198 0,840326 299,15 0,03360 0,9968 81 354,15 0,4931 0,9710 225 498,15 25,501 0,833927 300,15 0,03564 0,9966 82 355,15 0,5133 0,9704 230 503,15 27,976 0,827328 301,15 0,03778 0,9963 83 356,15 0,5342 0,9697 235 508,15 30,632 0,820529 302,15 0,04004 0,9960 84 357,15 0,5557 0,9691 240 513,15 33,478 0,813630 303,15 0,04241 0,9957 85 358,15 0,5780 0,9684 245 518,15 36,523 0,806531 304,15 0,04491 0,9954 86 359,15 0,6011 0,9678 250 523,15 39,776 0,799232 305,15 0,04753 0,9951 87 360,15 0,6249 0,9671 255 528,15 43,246 0,791633 306,15 0,05029 0,9947 88 361,15 0,6495 0,9665 260 533,15 46,943 0,783934 307,15 0,05318 0,9944 89 362,15 0,6749 0,9658 265 538,15 50,877 0,775935 308,15 0,05622 0,9940 90 363,15 0,7011 0,9652 270 543,15 55,058 0,767836 309,15 0,05940 0,9937 91 364,15 0,7281 0,9644 275 548,15 59,496 0,759337 310,15 0,06274 0,9933 92 365,15 0,7561 0,9638 280 553,15 64,202 0,750538 311,15 0,06624 0,9930 93 366,15 0,7849 0,9630 285 558,15 69,186 0,741539 312,15 0,06991 0,9927 94 367,15 0,8146 0,9624 290 563,15 74,461 0,732140 313,15 0,07375 0,9923 95 368,15 0,8453 0,9616 295 568,15 80,037 0,722341 314,15 0,07777 0,9919 96 369,15 0,8769 0,9610 300 573,15 85,927 0,712242 315,15 0,08198 0,9915 97 370,15 0,9094 0,9602 305 578,15 92,144 0,701743 316,15 0,09639 0,9911 98 371,15 0,9430 0,9596 310 583,15 98,70 0,690644 317,15 0,09100 0,9907 99 372,15 0,9776 0,9586 315 588,15 105,61 0,679145 318,15 0,09582 0,9902 100 373,15 1,0133 0,9581 320 593,15 112,89 0,666946 319,15 0,10086 0,9898 102 375,15 1,0878 0,9567 325 598,15 120,56 0,654147 320,15 0,10612 0,9894 104 377,15 1,1668 0,9552 330 603,15 128,63 0,640448 321,15 0,11162 0,9889 106 379,15 1,2504 0,9537 340 613,15 146,05 0,610249 322,15 0,11736 0,9884 108 381,15 1,3390 0,9522 350 623,15 165,35 0,574350 323,15 0,12335 0,9880 110 383,15 1,4327 0,9507 360 633,15 186,75 0,527551 324,15 0,12961 0,9876 112 385,15 1,5316 0,9491 370 643,15 210,54 0,451852 325,15 0,13613 0,9871 114 387,15 1,6362 0,9476 374,15 647,30 221,20000 0,315453 326,15 0,14293 0,9862 116 389,15 1,7465 0,946054 327,15 0,15002 0,9862 118 391,15 1,8628 0,9445
G-at_npsh_a_sc
TECHNICAL APPENDIX VAPOUR PRESSURE PS VAPOURPRESSURE AND ρ DENSITY OF WATER TABLE
78
TECHNICAL APPENDIX
TABLE OF FLOW RESISTANCE IN 100 m OF STRAIGHT CASTIRON PIPELINE (HAZEN-WILLIAMS FORMULA C=100)
m3/h l/min 15 20 25 32 40 50 65 80 100 125 150 175 200 250 300 350 4001/2" 3/4" 1" 1 1/4" 1 1/2" 2 2 1/2" 3" 4" 5" 6" 7" 8" 10" 12" 14" 16"
v 0,94 0,53 0,34 0,21 0,13 hr 16 3,94 1,33 0,40 0,13 The hr values must be multiplied by:v 1,42 0,80 0,51 0,31 0,20 0.71 for galvanized or painted steel pipeshr 33,9 8,35 2,82 0,85 0,29 0.54 for stainless steel or copper pipesv 1,89 1,06 0,68 0,41 0,27 0,17 0.47 for PVC or PE pipeshr 57,7 14,21 4,79 1,44 0,49 0,16 v 2,36 1,33 0,85 0,52 0,33 0,21hr 87,2 21,5 7,24 2,18 0,73 0,25v 2,83 1,59 1,02 0,62 0,40 0,25hr 122 30,1 10,1 3,05 1,03 0,35v 3,30 1,86 1,19 0,73 0,46 0,30hr 162 40,0 13,5 4,06 1,37 0,46v 2,12 1,36 0,83 0,53 0,34 0,20hr 51,2 17,3 5,19 1,75 0,59 0,16v 2,65 1,70 1,04 0,66 0,42 0,25hr 77,4 26,1 7,85 2,65 0,89 0,25v 3,18 2,04 1,24 0,80 0,51 0,30hr 108 36,6 11,0 3,71 1,25 0,35v 3,72 2,38 1,45 0,93 0,59 0,35hr 144 48,7 14,6 4,93 1,66 0,46v 4,25 2,72 1,66 1,06 0,68 0,40hr 185 62,3 18,7 6,32 2,13 0,59v 3,06 1,87 1,19 0,76 0,45 0,30hr 77,5 23,3 7,85 2,65 0,74 0,27v 3,40 2,07 1,33 0,85 0,50 0,33hr 94,1 28,3 9,54 3,22 0,90 0,33v 4,25 2,59 1,66 1,06 0,63 0,41hr 142 42,8 14,4 4,86 1,36 0,49v 3,11 1,99 1,27 0,75 0,50 0,32hr 59,9 20,2 6,82 1,90 0,69 0,23v 3,63 2,32 1,49 0,88 0,58 0,37hr 79,7 26,9 9,07 2,53 0,92 0,31v 4,15 2,65 1,70 1,01 0,66 0,42hr 102 34,4 11,6 3,23 1,18 0,40v 5,18 3,32 2,12 1,26 0,83 0,53 0,34hr 154 52,0 17,5 4,89 1,78 0,60 0,20v 3,98 2,55 1,51 1,00 0,64 0,41hr 72,8 24,6 6,85 2,49 0,84 0,28v 5,31 3,40 2,01 1,33 0,85 0,54 0,38hr 124 41,8 11,66 4,24 1,43 0,48 0,20v 6,63 4,25 2,51 1,66 1,06 0,68 0,47hr 187 63,2 17,6 6,41 2,16 0,73 0,30v 5,10 3,02 1,99 1,27 0,82 0,57 0,42hr 88,6 24,7 8,98 3,03 1,02 0,42 0,20v 5,94 3,52 2,32 1,49 0,95 0,66 0,49hr 118 32,8 11,9 4,03 1,36 0,56 0,26v 6,79 4,02 2,65 1,70 1,09 0,75 0,55hr 151 42,0 15,3 5,16 1,74 0,72 0,34v 7,64 4,52 2,99 1,91 1,22 0,85 0,62hr 188 52,3 19,0 6,41 2,16 0,89 0,42v 5,03 3,32 2,12 1,36 0,94 0,69 0,53hr 63,5 23,1 7,79 2,63 1,08 0,51 0,27v 6,28 4,15 2,65 1,70 1,18 0,87 0,66hr 96,0 34,9 11,8 3,97 1,63 0,77 0,40v 7,54 4,98 3,18 2,04 1,42 1,04 0,80hr 134 48,9 16,5 5,57 2,29 1,08 0,56v 8,79 5,81 3,72 2,38 1,65 1,21 0,93hr 179 65,1 21,9 7,40 3,05 1,44 0,75v 6,63 4,25 2,72 1,89 1,39 1,06 0,68hr 83,3 28,1 9,48 3,90 1,84 0,96 0,32v 8,29 5,31 3,40 2,36 1,73 1,33 0,85hr 126 42,5 14,3 5,89 2,78 1,45 0,49v 6,37 4,08 2,83 2,08 1,59 1,02 0,71hr 59,5 20,1 8,26 3,90 2,03 0,69 0,28v 7,43 4,76 3,30 2,43 1,86 1,19 0,83hr 79,1 26,7 11,0 5,18 2,71 0,91 0,38v 8,49 5,44 3,77 2,77 2,12 1,36 0,94hr 101 34,2 14,1 6,64 3,46 1,17 0,48v 6,79 4,72 3,47 2,65 1,70 1,18hr 51,6 21,2 10,0 5,23 1,77 0,73v 8,15 5,66 4,16 3,18 2,04 1,42hr 72,3 29,8 14,1 7,33 2,47 1,02v 6,61 4,85 3,72 2,38 1,65 1,21hr 39,6 18,7 9,75 3,29 1,35 0,64v 7,55 5,55 4,25 2,72 1,89 1,39hr 50,7 23,9 12,49 4,21 1,73 0,82v 8,49 6,24 4,78 3,06 2,12 1,56 1,19hr 63,0 29,8 15,5 5,24 2,16 1,02 0,53v 6,93 5,31 3,40 2,36 1,73 1,33hr 36,2 18,9 6,36 2,62 1,24 0,65
G-at-pct_a_th
hr = flow resistance for 100m of straight pipeline (m)V = water speed (m/s)
420 7000
600 10000
8000480
540 9000
210 3500
360 6000
240 4000
300 5000
180 3000
2000120
150 2500
250
1500
100060
90
75 1250
500
800
600
400
90
175
48
36
24
15
10,5
18 300
30
4,2 70
3 50
150
12 200
4,8 80
0,9 15
0,6 10
5,4
1,2 20
1,8 30
2,1 35
1,5 25
2,4 40
3,6 60
6 100
7,5 125
FLOW RATE NOMINAL DIAMETER in mm and INCHES
105 1750
42 700
54 900
9
79
TECHNICAL APPENDIX
FLOW RESISTANCE
TABLE OF FLOW RESISTANCE IN BENDS, VALVES ANDGATES
The flow resistance is calculated using the equivalent pipeline length method according to the table below:
The table is valid for the Hazen Williams coefficient C = 100 (cast iron pipework). For steel pipework, multiply thevalues by 1.41. For stainless steel, copper and coated cast iron pipework, multiply the values by 1.85.When the equivalent pipeline length has been determined, the flow resistance is obtained from the tableof flow resistance.The values given are guideline values which are bound to vary slightly according to the model, especially for gatevalves and non-return valves, for which it is a good idea to check the values supplied by the manufacturers.
ACCESSORY
TYPE 25 32 40 50 65 80 100 125 150 200 250 300
45° bend 0,2 0,2 0,4 0,4 0,6 0,6 0,9 1,1 1,5 1,9 2,4 2,890° bend 0,4 0,6 0,9 1,1 1,3 1,5 2,1 2,6 3,0 3,9 4,7 5,890° smooth bend 0,4 0,4 0,4 0,6 0,9 1,1 1,3 1,7 1,9 2,8 3,4 3,9Union tee or cross 1,1 1,3 1,7 2,1 2,6 3,2 4,3 5,3 6,4 7,5 10,7 12,8Gate - - - 0,2 0,2 0,2 0,4 0,4 0,6 0,9 1,1 1,3Non return valve 1,1 1,5 1,9 2,4 3,0 3,4 4,7 5,9 7,4 9,6 11,8 13,9
G-a-pcv_a_th
DN
Equivalent pipeline length (m)
80
TECHNICAL APPENDIX
VOLUMETRIC CAPACITY
Litresper minute
Cubic metresper hour
Cubic feetper hour
Cubic feetper minute
Imp. gal.per minute
US gal.per minute
l/min m3/h ft3/h ft3/min Imp. gal/min Us gal./min1,0000 0,0600 2,1189 0,0353 0,2200 0,2640
16,6670 1,0000 35,3147 0,5886 3,6660 4,40300,4720 0,0283 1,0000 0,0167 0,1040 0,1250
28,3170 1,6990 60,0000 1,0000 6,2290 7,48004,5460 0,2728 9,6326 0,1605 1,0000 1,20103,7850 0,2271 8,0209 0,1337 0,8330 1,00000,1100 0,0066 0,2339 0,0039 0,0240 0,0290
PRESSURE AND HEAD
Newtons persquare metre
kilopascal bar Pound forceper square inch
metreof water
millimetreof mercury
N/m2 kPa bar psi m H2O mm Hg1,0000 0,0010 1 x 105 1,45 x 10-4 1,02 x 10-4 0,0075
1000,0000 1,0000 0,0100 0,1450 0,1020 7,5000100000,0000 100,0000 1,0000 14,5000 10,2000 750,1000
98067,0000 98,0700 0,9810 14,2200 10,0000 735,60006895,0000 6,8950 0,0690 1,0000 0,7030 51,72002984,0000 2,9840 0,0300 0,4330 0,3050 22,42009789,0000 9,7890 0,0980 1,4200 1,0000 73,4200133,3000 0,1330 0,0013 0,0190 0,0140 1,0000
3386,0000 3,3860 0,0338 0,4910 0,3450 25,4000
LENGTH
millimetre centimetre metre inch foot yardmm cm m in ft yd
1,0000 0,1000 0,0010 0,0394 0,0033 0,001110,0000 1,0000 0,0100 0,3937 0,0328 0,0109
1000,0000 100,0000 1,0000 39,3701 3,2808 1,093625,4000 2,5400 0,0254 1,0000 0,0833 0,0278
304,8000 30,4800 0,3048 12,0000 1,0000 0,3333914,4000 91,4400 0,9144 36,0000 3,0000 1,0000
VOLUME
cubic metre litre millilitre imp. galloon US gallon cubic footm3 litre ml imp. gal. US gal. ft3
1,0000 1000,0000 1 x 106 220,0000 264,2000 35,31470,0010 1,0000 1000,0000 0,2200 0,2642 0,0353
1 x 10-6 0,0010 1,0000 2,2 x 10-4 2,642 x 10-4 3,53 x 10-50,0045 4,5460 4546,0000 1,0000 1,2010 0,16050,0038 3,7850 3785,0000 0,8327 1,0000 0,13370,0283 28,3170 28317,0000 6,2288 7,4805 1,0000
G-at_pp_a_sc
81
82
RETE COMMERCIALE ITALIANA “WATER TECHNOLOGY GROUP - EMEA”“WATER TECHNOLOGY GROUP - EMEA” ITALIAN SALES NETWORK
RETE COMMERCIALE EUROPEA “WATER TECHNOLOGY GROUP - EMEA”“WATER TECHNOLOGY GROUP - EMEA” EUROPEAN SALES NETWORK
LOWARA S.r.l. - 36075 Montecchio Maggiore - Vicenza - Italy - Tel. +39 0444/707111 - Telefax +39 0444/492166 - e-mail: [email protected] - http://www.lowara.com
LOWARA si riserva il diritto di apportare modifiche senza obbligo di preavviso — LOWARA reserves the right to make modifications without prior notice
LOWARA PORTUGAL, LdaPraceta da Castanheira, 38 - 4475-019 Barca PortugalTel. 00351 22 9478550 - Fax: 00351 22 9478570e-mail: [email protected]://www.lowara.pt
LOWARA UK Ltd.Millwey Rise Industrial Estate - Axminster, Devon EX 13 5HU - GBTel. 01297 630200 - Fax: 01297 630270e-mail: [email protected] - http://www.lowara.co.uk
LOWARA IRELAND Ltd.59 Broomhill Drive - Tallaght Industrial EstateTallaght - DUBLIN 24 - EIRETel. (1) 4520266 - Fax: (1) 4520725e-mail: [email protected]://www.lowara.ie
LOWARA VOGEL POLSKA Sp. z o.o.UL. WORCELLA 16 - PL - 40-652 KATOWICEPh. 0048 32 202 8904 - Fax 0048 32 202 5452
PUMPENFABRIK ERNST VOGEL GmbHErnst Vogel-Strasse 2 - A-2000 STOCKERAUTel. 0043 2266 604 - Fax 0043 2266 65311e-mail: [email protected]://www.vogel-pumpen.com
LOWARA DEUTSCHLAND GmbHBiebigheimer Straße 1263762 Großostheim - (OT Wenigumstadt) - DTel. 0 60 26 9 43 - 0Fax: 0 60 26 9 43 - 2 10e-mail: [email protected]://www.lowara.de
LOWARA FRANCE S.A.S.BP 57311 - 37073 TOURS CEDEX 2Tel. (0033) 02 47 88 17 17Fax: (0033) 02 47 88 17 00e-mail: [email protected]://www.lowara.fr
LOWARA FRANCE SAS Agence SudZ.I. La SipièreBP 2313730 Saint Victoret - FTél. (0033) 04 42 10 02 30Fax (0033) 04 42 10 43 75
LOWARA NEDERLAND B.V.POSTBUS 544180 BB WaardenburgTel. 0031 - (0)418 - 65 50 60Fax: 0031 - (0)418 - 65 50 61e-mail: [email protected] http://www.lowara.nl
BARI70026 Modugno Bari Via X Marzo, 110 PTel. 080 5327453 - 5353808Fax: 080 5327926e-mail: [email protected]
BOLOGNA40132 Bologna - Via Panigale, 74/CTel. 051 6415666Fax: 051 6415527e-mail: [email protected]
BRESCIA25124 Brescia - Via Volta, 37Tel. 030 3531909Fax: 030 3534661e-mail: [email protected]
CAGLIARI09100 Cagliari - Via Dolcetta, 19Tel. 070 287762 - 292192Fax: 070 280946e-mail: [email protected]
CATANIA95027 S. Gregorio - CataniaVia XX Settembre, 75Tel. 095 7123226 - 7123987Fax: 095 498902e-mail: [email protected]
CHIETI66020 Sambuceto di S. GiovanniTeatino Via Aldo Moro, 125Tel. 085 4461360 - 4460231 - 4460449Fax 085 4460630e-mail: [email protected]
MILANO20090 Trezzano sul Naviglio MilanoVia Goldoni, 29Tel. 02 48464476 - Fax: 02 4451634e-mail: [email protected]
NAPOLI80017 Melito di Napoli - NapoliCorso Europa, 369 - Scala “A” int. 11-12Tel. 081 7113065 - 7113631Fax: 081 7115761e-mail: [email protected]
PADOVA35020 Albignasego - Via A. Volta, 56Zona MandriolaTel. 049 8801110 - 8801408Fax: 049 8801408e-mail: [email protected]
PERUGIA06100 PerugiaVia Settevalli, 133C, Torre 2 - 3° PianoCentro Direzionale Piazza SettevalliTel. 075 5057126 - Fax: 075 5051242e-mail: [email protected]
PISA56025 Località Gello di Pontedera - PisaVia di Gello, 55Tel. 0587 296264 - 296286Fax: 0587 296410e-mail: [email protected]
PORDENONE33082 Azzano Decimo PordenoneViale 1° Maggio, 65/1 Area 53Tel. 0434 633243Fax: 0434 632729e-mail: [email protected]
ROMA00173 Roma - Via Frascineto, 8Tel. 06 7235890 (2 linee)Fax: 06 7234617e-mail: [email protected]
TORINOVia Torre Pellice, 17 - 10156 TorinoTel. 011 2979022 - 2979046Fax: 011 2979001e-mail: [email protected]
VICENZA36061 Bassano del Grappa - VIVia Pigafetta, 6Tel. 0424 566776 (R.A. 3 Linee)Fax: 0424 566773e-mail: [email protected]
Lowara is a brand of ITT Water Technology - a subsidiary of ITT Industries
Numero Unico
848 787011
®
Do it 100%
RECYCLEDPAPER
cod. 191005961 03/06
For Italian Market only