Airtronic M Order no. Airtronic D3, 12 V 25 2317 05 00 00 Airtronic B4, 12 V 20 1812 05 00 00 Airtronic D4, 12 V 25 2113 05 00 00 Airtronic D4, 24 V 25 2114 05 00 00 Airtronic D4 Plus, 12 V 25 2484 05 00 00 Airtronic D4 Plus, 24 V 25 2498 05 00 00 Airtronic D4S, 12 V 25 2144 05 00 00 Airtronic D4S, 24 V 25 2145 05 00 00 Airtronic D3 Camper, 12 V (see Airtronic D3) Airtronic D4 Camper, 12 V 25 2318 05 00 00 Airtronic D4 Camper plus, 12 V 25 2327 05 00 00 AIRTRONIC / AIRTRONIC M Troubleshooting and Repair Instructions 25 2115 95 19 01 12.2011 Airtronic Order no. Airtronic D2, 12 V 25 2069 05 00 00 Airtronic D2, 24 V 25 2070 05 00 00 Airtronic D2 Camper, 12 V 25 2326 05 00 00 Complete package Airtronic D2, 12 V 25 2115 05 00 00 Airtronic D2, 24 V 25 2116 05 00 00 Air heater for diesel and petrol operating independently of the engine. https://eberspacher-russia.ru
Transcript
Page 1: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

Airtronic M Orderno.

AirtronicD3,12V 252317050000

AirtronicB4,12V 201812050000

AirtronicD4,12V 252113050000AirtronicD4,24V 252114050000

AirtronicD4Plus,12V 252484050000AirtronicD4Plus,24V 252498050000

AirtronicD4S,12V 252144050000AirtronicD4S,24V 252145050000

AirtronicD3Camper,12V(seeAirtronicD3)

AirtronicD4Camper,12V 252318050000

AirtronicD4Camperplus,12V 252327050000

AIRTRONIC / AIRTRONIC M Troubleshooting and Repair Instructions

25211595190112.2011

Airtronic Orderno.

AirtronicD2,12V 252069050000AirtronicD2,24V 252070050000AirtronicD2Camper,12V 252326050000

Completepackage

AirtronicD2,12V 252115050000AirtronicD2,24V 252116050000

Air heater for diesel and petrol operating independently of the engine.

https://eberspacher-russia.ru

Page 2: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

2

4

3

1

2

1Contents

ThislistofcontentsgivesyoupreciseinformationaboutthecontentsoftheTroubleshootingandRepairInstructions.

Introduction

Usetheindex,listofabbreviations,etc,tolookforaterm,technicalwordoranexplanationforanabbreviation.

Chapter Title Contents Page

Introduction • Foreword.................................................................................................................. 4 • Accidentprevention.................................................................................................. 4 • Specialtextstructure,presentationandpicturesymbols........................................... 4 • Importantinformationbeforestartingwork................................................................ 4

Function and use Cutawayview............................................................................................................ 5 • Descriptionoffunctions – Switchingon.......................................................................................................... 6 – StartingtheAirtronic.............................................................................................. 6 – StartingtheAirtronicM.......................................................................................... 6 – Temperatureselectionwiththecontrolelement...................................................... 6 – Controlinheatingmode......................................................................................... 6 – Ventilatingmode.................................................................................................... 6 – Switchingoff.......................................................................................................... 6 • Controlandsafetydevices........................................................................................ 7 – Forcedshut-downforADRoperation..................................................................... 7 – Emergencyshutdown–EMERGENCYOFF........................................................... 7

Technical data • Airtronic(fordiesel)................................................................................................... 8 • AirtronicM(forpetrol)................................................................................................ 9 • AirtronicM(fordiesel)........................................................................................ 10,11 • Checkvalues – Testspeedfortheblower..................................................................................... 12 – Resistan\cevalues............................................................................................... 12 – Switchingvalue.................................................................................................... 12 – Exhaustemissionspecification............................................................................. 12 – Check“externaltemperaturesensor”................................................................... 12 – Tableofvalues:“Externaltemperaturesensor”..................................................... 12

Troubleshooting • Whattocheckfirstincaseoffaults – Check.................................................................................................................. 13 – Electricalcomponents.......................................................................................... 13 – Measurebatteryvoltage....................................................................................... 13 – Measuresvoltagesupply..................................................................................... 13 – Checkswitch-onsignal........................................................................................ 13 – Checkcontrolunit................................................................................................ 13 • Overviewoftheindividualtestequipmentandcontrolunits..................................... 14 • Lockingthecontrolbox........................................................................................... 14 • Cancelthecontrolboxlock..................................................................................... 14 • Importantnotes(diagnosisofheaterswithmini-controller)....................................... 14 • Testingdeviceforthecontroldevice........................................................................ 15 • Faultdiagnosisusingthediagnosticunit........................................................... 15,16 • FaultdiagnosisusingtheEDiTHdiagnosticstoolwithISOadapter.......................... 17 • AirpressuresensordiagnosisusingEDiTHdiagnosticstoolandISOadapter.......... 18 • FaultdiagnosisusingtheEDiTHdiagnosticstoolwithbasicadapter....................... 19 • Faultdiagnosisusingthemoduletimer.................................................................... 20 • FaultdiagnosisusingtheradioremotecontrolTP5................................................. 21 • FaultdiagnosisusingtheEasyStartR+radioremotecontrolor theEasyStartTtimer............................................................................................... 22 • Faultcodetable...............................................................................................23–27

https://eberspacher-russia.ru

Page 3: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

3

Introduction

7

6

5

1

Chapter Title Contents Page

Repair instructions • Repairinstructions.................................................................................................. 28 • Alwaysobservethefollowingsafetyinstructionsbeforeworkingontheheater........ 28 • Specialtool,AMPreleasetool................................................................................. 28 • AssemblydrawingAirtronic/AirtronicM................................................................. 29 • Repairstep1,removetheheatercover................................................................... 30 • Repairstep2,dismantlecontrolbox,checkcontrolbox......................................... 30 • Repairstep3,dismantleglowplug.......................................................................... 31 • Repairstep4,renewlining...................................................................................... 31 • Repairstep5,dismantlecombinationsensor(overheating/flamesensor............... 32 • Repairstep6,installcombinationsensor(overheating/flamesensor)..................... 33 • Repairstep7,dismantleheatexchanger/ dismantlecombustionairfan................................................................................... 34 • Repairstep8,dismantlecombustionchamber........................................................ 35 • Checkfuelsupply.................................................................................................... 36 • Measuringthefuelquantity...................................................................................... 36

Circuit diagrams Overviewofthepartslistsandcircuitdiagrams........................................................... 37 • PartslistcircuitdiagramsAirtronic/AirtronicM....................................................... 38 • CircuitdiagramAirtronic/AirtronicM..................................................................... 39 Thiscircuitdiagramisvalidforheaterswithonediagnosiscable andacontrolboxcableloomwichisfirmlyencapsulated. • CircuitdiagramAirtronic/AirtronicM..................................................................... 40 Thiscircuitdiagramisforheaterswith2diagnosticscableandwhose controlboxcableloomiswoundwithcabletape. • Partslistcircuitdiagrams,controlunits.................................................................... 41 • Circuitdiagramcontrolunits–part1....................................................................... 42 • Circuitdiagramcontrolunits–part2....................................................................... 43 • Circuitdiagramcontrolunits–part3....................................................................... 44 • Circuitdiagramcontrolunits–part4....................................................................... 45 • Circuitdiagramcontrolunits–part5....................................................................... 46 • Circuitdiagramcontrolunits–part6....................................................................... 47 • Circuitdiagramcontrolunits–part7....................................................................... 48 • PartslistcircuitdiagramcontrolunitEasyStartR+/R/T........................................ 49 • CircuitdiagramcontrolunitEasyStartR+(controlboxwith1diagnosticscable)...... 50 • CircuitdiagramcontrolunitEasyStartR+(controlboxwith1diagnosticscable)...... 51 • CircuitdiagramcontrolunitEasyStartR+(controlboxwith2diagnosticscable)...... 52 • CircuitdiagramcontrolunitEasyStartR(controlboxwith1/2diagnosticscables). 53 • CircuitdiagramcontrolunitEasyStartR(controlboxwith2diagnosticscables)...... 54 • CircuitdiagramcontrolunitEasyStartR(controlboxwith1diagnosticscables)...... 55 • CircuitdiagramcontrolunitEasyStartT(controlboxwith1diagnosticscable)........ 56 • CircuitdiagramcontrolunitEasyStartT(controlboxwith2diagnosticscable)........ 57 • PartslistcircuitdiagramsAirtronic/AirtronicM–ADR............................................ 58 • CircuitdiagramAirtronic/AirtronicM–ADR.......................................................... 59 1encapsulateddiagnosticscableandcontrolboxcableloomfirmlyencapsulated • CircuitdiagramAirtronic/AirtronicM–ADR.......................................................... 60 2diagnosticscablesandcontrolboxcableloomwithcabletape • Partslistcircuitdiagrams,controlunits–ADR......................................................... 61 • Partslistcircuitdiagrams,controlunits–EasyStartT–ADR................................... 61 • Circuitdiagramcontrolunits–ADR......................................................................... 62 • CircuitdiagramcontrolunitEasyStartT–ADR(controlboxwith1diag.cable)....... 63 • CircuitdiagramcontrolunitEasyStartT–ADR(controlboxwith2diag.cable)....... 64

Service • Certification............................................................................................................. 65 • Disposal.................................................................................................................. 65 • ECDeclarationofConformity.................................................................................. 65 • Listofkeywords..................................................................................................... 66 • Listofabbreviations................................................................................................ 67

https://eberspacher-russia.ru

Page 4: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

4

Special text structure, presentation and picture symbols

Specialtextformatsandpicturesymbolsareusedintheseinstructionstoemphasisedifferentsituationsandsubjects.Pleaserefertothefollowingexamplesfortheirmeaningsandappropriateaction.

Special text formats and presentations• Adot(•)indicatesalist,whichisstartedbyaheading.

– Ifanindenteddash(–)followsa“dot”,thislistisasub-sectionoftheblackdot.

Picture symbols

Danger!Thisinformationpointsoutadangeroussituationforapersonand/ortheproduct.Failuretocomplywiththeseinstructionscanresultininjuriestopeopleand/ordamagetomachinery.

Caution!Thisinformationpointsoutadangeroussituationforapersonand/ortheproduct.Failuretocomplywiththeseinstructionscanresultininjuriestopeopleand/ordamagetomachinery.

Important information before starting work

Initial commissioning of the heater or functional test after a repair

• Afterinstallingtheheater,thewholefuelsupplysystemmustbecarefullyvented:pleaserefertoandfollowthevehiclemanufacturer’sinstructions.

• Duringtheheatertrialrun,allfuelconnectionsmustbecheckedforleaksandsecure,tightfit.

• Iffaultsoccurwhiletheheaterisrunning,useadiagnosticunittodetermineandcorrectthecauseofthefault.

1 IntroductionForeword

TheseTroubleshootingandRepairInstructionsareapplicabletotheheaterslistedonthetitlePage,totheexclusionofallliabilityclaims.Dependingontheversionorrevisedstatusoftheheater,theremaybedifferencesbetweenitandthesetroubleshootingandrepairinstructions.Theusermustcheckthisbeforecarryingouttherepairworkand,ifnecessary,takethedifferencesintoaccount.

Caution!Safety instructions for installation and repair!

ImproperinstallationorrepairofEberspächerheaterscancauseafireorresultpoisonousexhaustenteringtheinsideofthevehicle.Thiscancauseseriousandevenfatalrisks.

Theheatermayonlybeinstalledaccordingtothespecifica-tionsinthetechnicaldocumentsorrepairedusingoriginalsparepartsbyauthorisedandtrainedpersons.Installationandrepairsbyunauthorisedanduntrainedper-sons,repairsusingnon-originalsparepartsandwithoutthetechnicaldocumentsrequiredforinstallationandrepairaredangerousandthereforearenotpermitted.

Arepairmayonlybecarriedoutinconnectionwiththere-spectiveunit-relatedtechnicaldescription,installationinstruc-tions,operatinginstructionsandmaintenanceinstructions.Thisdocumentmustbecarefullyreadthroughbefore/duringinstallationandrepairandfollowedthroughout.Particularattentionistobepaidtotheofficialregulations,thesafetyinstructionsandthegeneralinformation.

Please note!

Therelevantrulesofsoundengineeringpracticeandanyinformationprovidedbythevehiclemanufactureraretobeobservedduringtheinstallationandrepair.Eberspächerdoesnotacceptanyliabilityfordefectsanddamage,whichareduetoinstallationorrepairbyunauthor-isedanduntrainedpersons.Compliancewiththeofficialregulationsandthesafetyinstruc-tionsisprerequisiteforliabilityclaims.Failuretocomplywiththeofficialregulationsandsafetyinstructionsleadstoexclu-sionofanyliabilityoftheheatermanufacturer.

Accident prevention

Generalaccidentpreventionregulationsandthecorrespond-ingworkshopandoperatingsafetyinstructionsaretobeobserved.

https://eberspacher-russia.ru

Page 5: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

5

Cutaway view

1 Heaterimpeller 2 Controlbox 3 Combustionairfanimpeller 4 Glowplug 5 Cover 6 Heatexchanger 7 Combinationsensor(overheating/flamesensor) 8 Radioremotecontrol(mobileunit) 9 Radioremotecontrol(stationaryunit)10 Button11 Temperaturesensor(roomtemperature)12 Fusebracketwithmainfuseand“actuation”fuse13 Electricalmotor14 Fuelconnection15 Flangeseal

16 Combustionchamber17 Outlethood18 Combustionairhose19 Meteringpump20 Pot-typestrainer,installedinthedosingpump21 Outflow22 FlexibleexhaustpipeF= FreshairW= HotairA= ExhaustB= FuelV= Combustionair

Functionanduse2

https://eberspacher-russia.ru

Page 6: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

6

Description of functions

Switching on

Whentheheaterisswitchedon,thecontrollampinthecon-trolunitlightsup.Theglowplugisswitchedonandthefanstartsatlowspeed.

fthereisstilltoomuchresidualheatintheheatexchangerfromwhentheheaterwaslastused,firstlyonlythefanstartsup(coldblowing).Oncetheresidualheathasbeencleared,theheaterstarts.

Starting Airtronic

Afterapprox.65secondsthefuelsupplystartsandthefuel/airmixtureinthecombustionchamberignites.Oncethecombinedsensor(flamesensor)hasdetectedtheflame,theglowplugisswitchedoffafter60seconds.Theheaterisnowinstandardoperation.

Starting Airtronic M

Afterapprox.60secondsthefuelsupplystartsandthefuel/airmixtureinthecombustionchamberignites.Aftertheflamesensorhasdetectedtheflame,theglowplugisswitchedoffafterapprox.90sec.Theheaterisnowinstandardoperation.Afteranother120seconds,theheaterhasreachedthe“POWER”stage(maximumfuelquantity,maximumfanspeed).

Temperature selection with the control element

Thecontrolcanbeusedtopreselectaninteriortemperature.Theresultingtemperaturecanbewithintherangeof+10°Cto+30°Canddependsontheselectedheater,onthesizeofthespacetobeheatedandontheprevailingoutdoortem-perature.Thesettingtobeselectedatthecontrolisanempiricalvalue.

Control in the heating mode

Duringtheheatingmode,theroomtemperatureorthetem-peratureofthesuckedinheatingairisconstantlymeasured.Ifthetemperatureishigherthanthetemperatureselectedonthecontrolelement,theheaterstartstoregulateitsoutput.Thereare4controlstagessothattheoutflowofheatpro-ducedbytheheatercanbeadjustedfinelytotheheatingrequirements.Fanspeedandfuelquantitycorrespondtotheparticularcontrolstage.Ifthesettemperatureisstillexceededinthesmallestcontrolstage,theheatergoestothe“OFF”stagewiththefanrunningonforapprox.4minutestocooloff.Thefanthencontinuesrunningatminimumspeed(circulationmode)untiltherestartorisswitchedoff(freshairmodewithexternaltemperaturesensor).

Ventilating mode

TheEasyStartR+andEasyStartTcontrolunitsandthemini-controllercanbeusedtoactivatethe„Ventilate“function.The„Heat/Ventilate“switchisalsorequiredforthemodulartimerandcontroldevicewhereby,forfanmode,the„Heat/Ventilate“switchmustbepressedfirstandthentheheaterswitchedon.Theblowerrunsatmaximumspeedinfanmode.

Switching off

Whentheheaterisswitchedoff,thecontrollampgoesoffandthefuelsupplyisswitchedoff.Thefanrunsonforapprox.4minutestocooldown.Whilethefanisrunningon,theglowplugisswitchedonforapprox.40secondstoclean.Specialcase:Ifnofuelhasbeensuppliedoriftheheaterisinthe“OFF”stageuntilitisswitchedoff,theheaterisstoppedwithoutanyafterrunning.

Functionanduse2

Please note!

https://eberspacher-russia.ru

Page 7: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

7

Forced shut-down for ADR operation

Invehiclesforthetransportofdangerousgoods(e.g.tankertrucks),theheatermustbeswitchedoffbeforethetruckdrivesintoadangerarea(refinery,petrolstation,etc.).Failuretocomplyresultsintheheaterautomaticallyswitchingoffif:• thevehicleengineisswitchedoff,• anadditionalunitisstartedup(auxiliarydriveforunloading

pump,etc.),• avehicledoorisopened(ADR99regulation,onlyinFrance).Thefanthenrunsonformax.40seconds.

Functionanduse2

Emergency shutdown – EMERGENCY OFFIfanemergencyshutdown–EMERGENCYOFF–isre-quiredduringoperation,executethefollowing:• Switchtheheateroffatthecontrolelementor• removethefuseor• disconnecttheheaterfromthebattery.

Control and safety devices

• Iftheheaterdoesnotignitewithin90secondsafterstartingthefuelpump,thestartisrepeated.Iftheheaterstilldoesnotigniteafteranother90secondsofpumpingfuel,theheaterisswitchedoff,i.e.thefuelsupplyisoffandthefanrunsonforapprox.4minutes.

• Iftheflamegoesoffbyitselfduringoperation,theheaterisrestarted.Iftheheaterdoesnotignitewithin90secondsafterthefuelpumphasstarted,orignitesandgoesoffagainwithin15minutes,theheaterisswitchedoff,i.e.thefuelsupplyisoffandthefanrunsonforapprox.4minutes.Thisstatuscanberemediedbybrieflyswitchingoffandonagain.Donotrepeattheswitchingoff/onroutinemorethantwice.

• Inthecaseofoverheating,thecombinedsensor(flamesensor/overheatingsensor)triggers,thefuelsupplyisinterruptedandtheheaterswitchedoff.Oncethecauseoftheoverheatinghasbeeneliminated,theheatercanbere-startedbyswitchingoffandonagain.

• Iftheloweroruppervoltagelimitisreached,theheaterisswitchedoffafter20seconds.

• Theheaterdoesnotstartupiftheglowplugorblowermo-torisdefectiveoriftheelectricleadtothemeteringpumpisinterrupted.

• Ifthecombinedsensor(flamesensor/overheatingsensor)isdefectortheelectricleadinterrupted,theheaterstartsupandisthenswitchedoffagainduringthestartphase.

• Thespeedofthefanmotorismonitoredcontinuously.Ifthefanmotordoesnotstartuporifthespeeddeviatesbymorethan10%,theheaterisswitchedoffafter30sec.

• Whentheheaterisswitchedoff,theglowplugis switchedonfor40seconds(after-glowing)whilethe fanrunsontocleanoffanycombustionresidues.

Please note!

Donotrepeattheswitchingoff/onroutinemorethantwice.

https://eberspacher-russia.ru

Page 8: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

8

Technichaldata3

Providednolimitvaluesaregiven,thetechnicaldatalistedissubjecttothetolerancesusuallyapplicabletoheatersof±10%fornominalvoltage,ambienttemperature20°CandreferencealtitudeEsslingen.

Caution!Safety instructions for technical data!Failuretocomplywiththetechnicaldatacanresultinmalfunc-tions.

Technichal data

Heatertype

Heater

Version

Heatingmedium

Controloftheheatflow

Heatflow(watt)

Heaterairflowratewithoutcounterpressure(kg/h) withhoodØ60mm

Fuelconsumption(l/h)

Elektr.powerconsumption(watt)

inoperation(12and24volt)

atstart(12and24volt)

Ratedvoltage

Operatingrange Lowervoltagelimit:Anundervoltageprotectioninthe

controllerswitchesofftheheaterwhenthevoltagelimitisreached.

Uppervoltagelimit: Anuppervoltageprotectioninthecontrollerswitchesoffthe

heaterwhenthevoltagelimitisreached.

Fuel

Tolarableambienttemperature

Heater

Dosingpump

Maximumairintaketemperature

Interferencesuppression

Weight

Ventilationmode

Airtronic

AirtronicD2/AirtronicD2Camper

D2/D2Camper

Air

Stage

Power Large Medium Small Off

2200 1800 1200 850 –

105 90 60 40 13

0.28 0.23 0.15 0.10 –

34 22 12 8 5

#100

12or24volt

approx.10.5voltresp.21voltUndervoltageprotectiontriggertime:20seconds

approx.16voltresp.32voltOvervoltageprotectiontriggertime:20seconds

DieselDINEN590(commerciallyavailable)

inoperation nooperation

–40°Cto+70°C –40°Cto+85°C

–40°Cto+50°C –40°Cto+125°C

max.+40°C

Interferencesuppressionclass5toDINEN55025

approx.2.7kg

possible

Please note!

https://eberspacher-russia.ru

Page 9: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

9

Technichaldata3Technichal data

Heatertype

Heater

Version

Heatingmedium

Controloftheheatflow

Heatflow(watt)

Heaterairflowratewithoutcounterpressure(kg/h) withhoodØ90mm

Fuelconsumption(l/h)

Elektr.powerconsumption(watt)

inoperation(12and24volt)

atstart(12and24volt)

Ratedvoltage

Operatingrange Lowervoltagelimit:Anundervoltageprotectioninthe

controllerswitchesofftheheaterwhenthevoltagelimitisreached.

Uppervoltagelimit: Anuppervoltageprotectioninthecontrollerswitchesoffthe

heaterwhenthevoltagelimitisreached.

Fuel

Tolarableambienttemperature

Heater

Dosingpump

Maximumairintaketemperature

Interferencesuppression

Weight

Ventilationmode

Airtronic M

AirtronicB4

B4

Air

Stage

Power Large Medium Small Off

3800 3200 2100 1300 –

185 160 120 85 24

0.54 0.46 0.29 0.18 –

40 29 15 9 5

#100

12volt

approx.10.5voltUndervoltageprotectiontriggertime:20seconds

16voltOvervoltageprotectiontriggertime:20seconds

PetrolDINEN228(commerciallyavailable)

inoperation nooperation

–40°Cto+50°C –40°Cto+85°C

–40°Cto+20°C –40°Cto+125°C

max.+40°C

Interferencesuppressionclass5toDINEN55025

ca.4.5kg

possible

Providednolimitvaluesaregiven,thetechnicaldatalistedissubjecttothetolerancesusuallyapplicabletoheatersof±10%fornominalvoltage,ambienttemperature20°CandreferencealtitudeEsslingen.

Caution!Safety instructions for technical data!Failuretocomplywiththetechnicaldatacanresultinmalfunc-tions.

Please note!

https://eberspacher-russia.ru

Page 10: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

10

Technichaldata3Technichal data

Heatertype

Heater

Version

Heatingmedium

Controloftheheatflow

Heatflow(watt) D3

D4

D4Plus

Heaterairflowratewithoutcounterpressure(kg/h) D3withhoodØ90mm

D4withhoodØ90mm

D4PluswithhoodØ75mm

Fuelconsumption(l/h) D3

D4

D4Plus

Elektr.powerconsumption(watt) D3

inoperation(12and24volt) D4

D4Plus

atstart(12and24volt)

Ratedvoltage

Operatingrange Lowervoltagelimit:Anundervoltageprotectioninthe

controllerswitchesofftheheaterwhenthevoltagelimitisreached.

Uppervoltagelimit: Anuppervoltageprotectioninthecontrollerswitchesoffthe

heaterwhenthevoltagelimitisreached.

Fuel

Tolarableambienttemperature

Heater

Dosingpump

Maximumairintaketemperature

Interferencesuppression

Weight

Ventilationmode

Airtronic M

AirtronicD3/AirtronicD4/AirtronicD4Plus

D3/D4/D4Plus

Air

Stage

Power Large Medium Small Off

3000 2200 1600 900 –

4000 3000 2000 900 –

4000 3000 2000 900 –

150 120 90 60 24

185 150 110 60 24

175 140 100 55 22

0.38 0.28 0.2 0.11 –

0.51 0.38 0.25 0.11 –

0.51 0.38 0.25 0.11 –

24 16 10 7 5

40 24 13 7 5

55 30 16 7 5

#100

12or24volt

approx.10.5voltresp.21voltUndervoltageprotectiontriggertime:20seconds

approx.16voltresp.32voltOvervoltageprotectiontriggertime:20seconds

DieselDINEN590(commerciallyavailable)

inoperation nooperation

–40°Cto+70°C –40°Cto+85°C

–40°Cto+50°C –40°Cto+125°C

max.+40°C

Interferencesuppressionclass5toDINEN55025

approx.4.5kg

possible

Providednolimitvaluesaregiven,thetechnicaldatalistedissubjecttothetolerancesusuallyapplicabletoheatersof±10%fornominalvoltage,ambienttemperature20°CandreferencealtitudeEsslingen.

Caution!Safety instructions for technical data!Failuretocomplywiththetechnicaldatacanresultinmalfunc-tions.

Please note!

https://eberspacher-russia.ru

Page 11: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

11

Technichaldata3Technichal data

Heatertype

Heater

Version

Heatingmedium

Controloftheheatflow

Heatflow(watt) D4S

D4Camper/D4CamperPlus

Heaterairflowratewithoutcounterpressure(kg/h) D4S

D4Camper/D4CamperPlus

Fuelconsumption(l/h)) D4S

D4Camper/D4CamperPlus

Elektr.powerconsumption(watt) D4S

inoperation(12and24v) D4Camper/D4CamperPlus

atstart(12and24v)

Ratedvoltage

Operatingrange Lowervoltagelimit:Anundervoltageprotectioninthe

controllerswitchesofftheheaterwhenthevoltagelimitisreached.

Uppervoltagelimit: Anuppervoltageprotectioninthecontrollerswitchesoffthe

heaterwhenthevoltagelimitisreached.

Fuel

Tolarableambienttemperature

Heater

Dosingpump

Maximumairintaketemperature

Interferencesuppression

Weight

Ventilationmode

Airtronic M

AirtronicD4S/Airtronic D4Camper/AirtronicD4CamperPlus

D4S/D4Camper/D4CamperPlus

Air

Stage

Power Large Medium Small Off

3500 3000 2000 1000 –

4000/3500 3000 2000 900 –

160 140 100 60 22

185/160 150/140 110/100 60/55 24/22

0.44 0.38 0.25 0.13 –

0.51/0.44 0.38 0.25 0.11 –

40 30 16 8 5

40 24/30 13/16 7/8 5

#100

12or24volt

approx.10.5voltresp.21voltUndervoltageprotectiontriggertime:20seconds

approx.16voltresp.32voltOvervoltageprotectiontriggertime:20seconds

DieselDINEN590(commerciallyavailable)

inoperation nooperation

–40°Cto+70°C –40°Cto+85°C

–40°Cto+50°C –40°Cto+125°C

max.+40°C

Interferencesuppressionclass5toDINEN55025

approx.4.5kg

possible

Providednolimitvaluesaregiven,thetechnicaldatalistedissubjecttothetolerancesusuallyapplicabletoheatersof±10%fornominalvoltage,ambienttemperature20°CandreferencealtitudeEsslingen.

Caution!Safety instructions for technical data!Failuretocomplywiththetechnicaldatacanresultinmalfunc-tions.

Please note!

https://eberspacher-russia.ru

Page 12: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

12

Check values

Test speed for the blower

Airtronic D2 / D2 Camper(12volt/24volt)• 12volt 5000rpm±25% atU=10,0volt• 24volt 5000rpm±25% atU=18,0volt

AirtronicB4 (12volt)AirtronicD3 / D3 Camper(12volt)AirtronicD4(12volt/24volt)AirtronicD4 Camper(12volt)• 12volt 4400rpm±25% atU=10,0volt• 24volt 4400rpm±25% atU=18,5volt

AirtronicD4S/Airtronic D4 Plus (12volt/24volt)AirtronicD4 Camper Plus (12volt)• 12volt 4400rpm±25% atU=10,5volt• 24volt 4400rpm±25% atU=19,0volt

Resistance values at 20 °C

12 volt 24 volt

Glowplug 0.42 –0.70 1.2 –2.0Dosingpump 9.5±0.50 36.0±1.8

Control unit resistance values

Switch position, left limit stop

Switch position, right limit stop

Controldevice12volt/24volt

min.1720max.1760

min.2096max.2216

Modulartimerandmini-controller12volt/24volt

min.1730max.1780

min.2120max.2240

Switching value Overheatingsensor 140°C–170°C measuredinthe“High”controlstage andatadistanceof300mmdownstream fromthehotairoutletExhaust emission specificationCO2 in exhaustincontrolstage“high” 7,5–12,5Vol.%SmokespotnumberaccordingtoBacharach <4

Temperature (°C)

Res

ista

nce

(ohm

)

2200

2000

1800

1600

1400

1200

1000±40 ±20 0 20 40±10±30 10 30

2400

50

Technicaldata3

Check “external” temperature sensor(OrderNo.:251774890300)The“external”temperaturesensortestmustbecarriedoutusingadigitalmultimeter.Iftheresistancevalueisnotthesameasthecurveinthediagramorthetableofvalues,re-placethetemperaturesensor.

Table of values – “external” temperature sensor

Temperature°C Resistance

min. max.0 1600 16605 1670 1730

10 1745 180015 1820 187020 1895 195025 1970 203030 2050 211035 2130 219040 2210 228045 2295 2370

https://eberspacher-russia.ru

Page 13: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

13

Troubleshooting4What to check first in case of faults

• Check– Fuelinthetank?– Fuelpipesleaking?(visualcheck)– Summerdieselinthefuelpipe?– Combustionairsystemorexhaustsystemdamagedor

blocked?– Hotairsystemblocked?– Airpressuresensorinstalled?Ifyes,referto„Whattodo

if…?“chapterofthe„AltitudeKit“installationinstructions.– Newgenerationcontrolboxinstalled? Features: >Cableloomofcontrolboxwoundwithcabletie >Temperaturesensormountedonthesideofthecontrol

box(visiblewhencoverremoved)

• Electrical components– Cables,connectionsdamaged?– Contactscorroded?– Fusesdefective?– Incorrectwiring?(shortcircuits,interrupted/broken)

• Measure battery voltage– Batteryvoltage<10.5volt,theundervoltageprotectionof

the12voltheaterhastriggered.– Batteryvoltage<21volt,theun

• Measure voltage supply (Cl 30) Disconnectthe16-pinconnectorS1/B1andmeasurethe

voltageappliedatconnectorB1betweenchamber1(cable2.52rt)andchamber10(cable2.52br).

Ifitdiffersfromthebatteryvoltage,checkthefuses,thesupplycables,thenegativeconnectionandthepositivesupportpointonthebatteryforvoltagedrop(corrosion/interruption).

• Check switch-on signal Disconnectthe16-pinconnectorS1/B1andthenswitch

ontheheateratthecontrolunit. CheckwhethervoltageisappliedintheconnectorB1

betweenchamber4(cable0.52ge)andchamber10(cable2.52br).

Ifnovoltageismeasured,thencheckthesupplycable(ca-ble0.52ge),the5Afuse(item2.7.1inthecircuitdiagram)andthecontrolunit.

• Check control unit

Control device, mini-timer, mini-controller and modular timer

Disconnecttheconnectoratthecontrolunit;installajumperbetweenthered0.5²rtcableandtheyellow0.5²gecable.

IfavoltageismeasuredinconnectorB1betweencham-ber4(cable0.5²ge)andchamber10(cable2.5²br),thenreplacethecontrolunit.

EasyStart R+ / EasyStart R / EasyStart T Disconnecttheconnectoratthecontrolunit;installajumper

betweentheyellow0.5²gecableandthered0.5²rtcable. IfavoltageismeasuredinconnectorB1betweencham-

ber8(cable0.5²ge)andchamber10(cable2.5²br),thenreplacethecontrolunit.

https://eberspacher-russia.ru

Page 14: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

14

Troubleshooting4Overview of the test equipment and control units suitable for diagnosis

Theelectroniccontrolboxcanstoreupto5faults,whichcanbereadoutanddisplayed.Thefollowingtestequipmentand/orcontrolunitscanbeusedtoquerythefaultmemoryinthecontrolboxandifnecessarytodeletethelockingofthecontrolbox:

Test equipment Order No.:

• Testingdevice forthecontroldevice 221509890000

• Diagnosticunit 221529890000 additionallyrequired: Adaptercable 221000318600

• EDiTHdiagnostictool – Basicadapterwithsoftware 221542890000 additionallyrequired: Airtronicextension 221537890000

– ISO-adapter 221541890000 additionallyrequired: Adaptercable 221000318600

– „Airpressuresensor“adaptercable221000333100 Onlyforheaterswithconnectedairpressuresensorfor

readingoutthe„airpressuresensor“faultmemory.

Ifadiagnosticscableisconnected,thefollowingcontrolunitscanalsobeused:

Control units Order No.:

• Moduletimer 221000303400

• TP5radioremotecontrol 221000320100

• EasyStartT 221000328800

• EasyStartR+ 221000328000

Please note!

Ifthefaultmemorycannotbereadout,checkthediagnosticscableforcorrectlayingandpossibledamage.

Important notes on diagnosis of heaters with mini-controller control unit

Caution!WhencheckingtheheaterwiththediagnosticsunitortheEDiTHdiagnosticstooltheordergiveninthefollowingnotesmustalwaysbefollowedasotherwisetheheaterdetectsError62(controlunit–interruption)andswitchestoemergencyoperation.

Mini-controller in stand-alone operation

• Connectadaptercable221000318600asdescribedintheoperatinginstruction.

• Selectoperatingmode(Heat/Ventilate)atthemini-control-ler

• PerformdiagnosisusingthediagnosticsunitortheEDiTHdiagnosticstool.

• Switchoffthemini-controllerafterfinishingthediagnosis• Removetheadaptercable

Mini-controller in combination with mini-timer

• Connectadaptercable221000318600asdescribedintheoperatinginstruction.

• Pressthembuttonofthemini-timer• Selectoperatingmode(seemini-timeroperatinginstruc-

tions)• PerformdiagnosisusingthediagnosticsunitortheEDiTH

diagnosticstool.• Switchoffthemini-timerafterfinishingthediagnosis• Removetheadaptercable

Mini-controller in combination with TP5

• Connectadaptercable221000318600asdescribedintheoperatinginstruction.

• Pressthe buttonoftheTP5radioremotecontrol• Selectoperatingmode(seeTP5radioremotecontroloper-

atinginstruction)• Performdiagnosis.• SwitchoffTP5radioremotecontrolafterfinishingthediag-

nosis• Removetheadaptercable

Please note!

IftheoperatingmodeistobechangedduringthetesttheheatermustbeswitchedofffirstusingthediagnosticsunitortheEDiTHdiagnosticstool,otherwisetheheaterdetectsError62(controlunit–interruption)andswitchestoemergencyoperation.

Test mini controller

Themini-controllermustbeconnectedtotheheaterfortest-ing.ThesetpointvaluecanbedisplayedusingtheEDiTHdiagnosticstool.Iftherotaryknobisattheleftlimitstopthesetpointvalueis8°C,attherightlimitstopitis34°C.

Please note!

Theresistanceofthesetpointvaluepotentiometercannotbemeasureddirectly.Themeasuredvaluesarenotmeaningful.

https://eberspacher-russia.ru

Page 15: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

15

Troubleshooting4Testing device for the control device(OrderNo.:221509890000)

Prepare for testConnectthecorrectoperatingvoltage(12or24volt)tothete-stingdevice,withplusattheredconnectorsocketandminusattheblueconnectorsocket.

• Disconnectsocketfromthecontrolunit.• Connectcableloomfromtestingdevicewiththecontrol

unit.• Settherotaryknobofthecontrolunitto“Heat”,thecorre-

spondingredLEDinthetestingdevicemustlightup.• Setcontrolunitto“0”,thenpressthe“LED–red”button,

theredcontrollampinthecontrolunitmustlightup.• Setcontrolunitto“Heat”,thenpressthe“LED–green”

button,correspondingredcontrollampinthetestingdeviceandthegreencontrollampinthecontrolunitmustlightup.

Caution!Safety instructions for checking the control unit!Ensureyouusethecorrectoperatingvoltage,otherwisetheconnectedcomponentscanbeseverelydamaged.

Check the setpoint potentiometer of the control unitSetthe“Temperaturesensor/Potentiometer”switchinthetestingdevicetothe“Potentiometer”settingandslowlyturntherotaryknobofthecontrolunit.ThegreenLED–temperaturesensor/potentiometermustlightupcontinuously.Incaseofafault,replacethecontrolunit.

1 Testingdevice2 Controldevice

Diagnostic unit(OrderNo.:221529890000)

Anadditionaladaptercableisrequiredtoconnectthediag-nosticunit(OrderNo.:221000318600).

Thecurrentfaultisdisplayedas“AF”anda2-digitnumberandisalwayswritteninthememorypositionF1.PrecedingfaultsaremovedtothememorylocationsF2–F5,ifnecessarythecontentsofmemorypositionF5isoverwrit-ten.

• Notonlythedefectivecomponent,butalsoadefectivecur-rentcircuitresultsinafaultbeingdisplayed.

• Inheaterswithconnectedairpressuresensorthediagnos-ticsunitcanbeusedtoreadoutthefaultmemoryoftheheateronly.

Thefaultmemoryofthe„airpressuresensor“canbereadoutusingtheEDiTHdiagnosticstoolonly.

• Faultcode,faultdescription,cause/remedialactionaredescribedonPages23–27.

l–Deletefaultmemoryl–Deletefaultmemoryd–Switchheateron/off,requestdiagnosise–Reverse,F5–F1f–Forward,F1–F5,currentfault(AF)

Connectdiagnosticsunit,seepage16.

Please note!

https://eberspacher-russia.ru

Page 16: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

16

Connect diagnostic unit• Disconnectthe8-pinconnectoroftheheater’scablehar-

nessandconnecttheadaptercable.• Connectthediagnosticunittotheadaptercable. Displayisasfollows:

Query fault memory• UsetheDkeytoswitchontheheater. Displayisasfollows:

• After8secthefollowingisdisplayed: Displayisasfollows:

Heaterhasnomalfunction or

e.g.currenterror/faultcode64

or

Faultdiagnosisnotpossible

Possiblecauses: – Adaptercableisnotproperlyconnected. – Controlboxisdefectiveorisnotcapableofdiagnosing

(notauniversalcontrolbox).

Display of the fault memory F1 – F5 or F5 – F1• Presstheeorfbutton,orpressseveraltimes,todisplay

thefaultmemory. Displayisasfollows:

e.g.faultmemory2/faultcode10

Onlythefaultmemorypositionswithanerrorassignedtothemaredisplayed.

Delete fault memory• PressbothLbuttonssimultaneouslyuntilthefollowingap-

pearsinthedisplay: Displayisasfollows:

• Ifthefaultmemoryhasbeendeletedthemostrecentcur-rentfaultisdisplayed.Thecurrentfaultisnotresetto00untiltheheaterisrestarted–providedthereisnonew,morerecentfault.

Displayisasfollows:

Heaterhasnomalfunction

Cancel the control box lock• Deletethefaultmemoryasdescribedandswitchoffthe

heaterusingthedkey.• Thecontrolboxlockiscancelledandthediagnosisclosed. Displayisasfollows:

Troubleshooting4

1 Heater2 Adaptercable3 Diagnosticunit

1

2

3

Please note!

https://eberspacher-russia.ru

Page 17: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

17

Troubleshooting4EDiTH diagnostic tool with ISO adapter(OrderNo.:221541890000)

AnadditionaladaptercableisrequiredtoconnecttheISOadapter(OrderNo.:221000318600).

• Itisveryimportanttoalwaysinstallinthegivenorder.• Notonlythedefectivecomponent,butalsoadefectivecur-

rentcircuitresultsinafaultbeingdisplayed.• Faultcode,faultdescription,cause/remedialactionare

describedonPages23–27.• TheEDiTHdiagnosticstoolscopeofsupplydoesnot

includethesoftware;thismustbedownloadedfromtheServicePortal.

Connect ISO adapter

• Disconnecttheheater’scableharness.• Connecttheadaptercabletothecableharness–asshown

inthesketch.• ConnecttheadaptercabletotheISOadapter.• ConnecttheSUB-DconnectioncablewiththePCandthe ISOadapter.

Installing the software on your PC• Doubleclickthe“setup.exe”filetostarttheinstallationand

followingtheSETUPprograminstructions.

Query / delete fault memory F1 – F5 or cancel the control box lock• StartthesoftwareonyourPC: – onthedesktop—>doubleclickthe“EDiTH”icon – Selectheatertype – Pressthe“GO”button.

• Deletefaultmemoryorcancelthecontrolboxlock: – pressthe“Deletefaultmemory”button —>thestoredfaultsF1–F5aredeletedandthecontrol

boxisunlocked.

Quit diagnosis• Pressthe“STOP”button—>faultmemoryqueryisended.

1 Heater2 Adaptercable3 ISOadapter

4 SUB-Dconnectioncable5 USBtoSerialRS-232adapter

Please note!

https://eberspacher-russia.ru

Page 18: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

18

Troubleshooting4Air pressure sensor diagnosis using EDiTH diagnostics tool and ISO adapter(OrderNo.221524890000)

AnadditionaladaptercableisrequiredtoconnecttheISOadapter(OrderNo.:221000333100).

Theairpressuresensorconnectedtotheheatercanbediag-nosed.Iffaultsoccurduringthealtitudeadjustmenttheyarestoredintheairpressuresensor.Ifnecessary,faultscanbereadoutusingtheISOadapterinconjunctionwiththeEDiTHdiagnosticstool–fromVersionS3V7-F–andtheadditionallynecessaryadaptercable.

Please note!

• Itisveryimportanttoalwaysinstallinthegivenorder.• Notonlythedefectivecomponent,butalsoadefectivecur-

rentcircuitresultsinafaultbeingdisplayed.• Faultcode,faultdescription,cause/remedialactionare

describedonpages27.• TheEDiTHdiagnosticstoolscopeofsupplydoesnot

includethesoftware;thismustbedownloadedfromtheServicePortal.

Perform diagnosis of the air pressure sensor

Disconnecttheconnectorbetweentheairpressuresensor/heater,controlunit,connecttheISOadapterwiththeadaptercable(seesketch).Startthediagnosisoftheairpressuresensor.

• Double-clickthe>>EDiTH<<icononthedesktop.• Selecttheairpressuresensorinthe»HeaterandTestSe-

lection«. Thefollowingactionsarepossible:

– Readoutthecurrentfaultandthefaultmemory.– Deletethefaultmemory.– Querythecurrentmeasuredairpressure.– Querytheoperatingstate.– Querythegeneraldata.– Printoutthefaultmemoryand/orthegeneraldata

• Exitthediagnosiswiththe»Stop«buttonorbyclosingallwindows.– Selection:Saveanalysis/Donotsaveanalysis

• RemoveISOadapterandadaptercablefromtheleadhar-nessandreconnecttheairpressuresensor/heater,controlunitconnector.

1 Airpressuresensor2 Adaptercable3 Cableloomfromheater4 Cableloomtocontrolunit

5 ISOadapter6 SUB-Dconnectioncable7 USBtoSerialRS-232adapter

https://eberspacher-russia.ru

Page 19: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

19

Caution! Magnetic field!Duringthetestoperationamagneticfielddevelopsattheadapter.Therefore,donotplaceanyobjectssuchasdatamedia,creditcards,etc.ontheadapterorinitsimmediatevicinity.

Troubleshooting4

(A) Basicadapter(B) SUB-Dconnectioncable(C) Mainsconnection(D) Mainsswitch(E) USBtoSerialRS-232adapter(F) Adapter(G) Controlbox

Cable colourssw = blackgn = greenbl = blue

EDiTH diagnostic tool with basic adapterEDiTHbasicadapter(OrderNo.:221542890000)

Anadditionalextensionisrequiredtocheckthecontrolbox(OrderNo.:221537890000).

• Itisimportanttoalwaysfollowthepreciseconnectionorderasgivenbelow!

• TheHallsensorintegratedinthecontrolboxcanonlybeproperlytestedinthecontrolboxiscorrectlyplacedontheextension.

• Onlypushorpullontheconnectors,notonthecables!• OnlyusethenetworkcableandRS232cablewithsnap

ferritesincludedinthescopeofsupply.Useoriginalacces-sorieswithsnapferritesonlytoconnectthetestequipment.

• Notonlythedefectivecomponent,butalsoadefectivecurrentcircuitresultsinafaultbeingdisplayed.

• Faultcode,faultdescription,cause/remedialactionaredescribedonPages23–27.

Connect basic adapter• Startcomputerandwaituntilthesystemhassuccessfully

booted.• StartPCsoftware.• Inserttheunitconnectorofthemainscableinthebasic

adapter(A)andconnectthemainsconnection(C)tothemains.

• ConnecttheSUB-Dconnectioncable(B)withthePCandbasicadapter(A).

Connect extension and test control box• Connecttheextensiontothebasicadapter(A).• Connectthecontrolbox(E)totheextensionandtheadap-

ter(F).• Switchonthebasicadapter(A)atthemainsswitch(D).• Selectthecontrolboxversionandoperatingvoltage

(12V/24V)inthePCsoftware.• StartthecontrolboxtestwiththePCsoftware.Amorede-

taileddescriptionofhowtooperatethebasicadapters(A)isgivenintheEDiTHonlinehelp.

Please note!

https://eberspacher-russia.ru

Page 20: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

20

Troubleshooting4Module timer(OrderNo.:221000303400)

Thecurrentfaultisdisplayedas“AF”andisalwayswritteninmemorypositionF1.PrecedingfaultsaremovedtothememorylocationsF2–F5,ifnecessarythecontentsofmemorypositionF5isoverwrit-ten.

• Notonlythedefectivecomponent,butalsoadefectivecur-rentcircuitresultsinafaultbeingdisplayed.

• Inheaterswithconnectedairpressuresensorthemodulartimercannotbeusedtoperformdiagnoses.Thediagnos-ticsunitortheEDiTHdiagnosticstoolmustbeusedtoperformthediagnosis.

Thefaultmemoryofthe„airpressuresensor“canbereadoutusingtheEDiTHdiagnosticstoolonly.

• Faultcode,faultdescription,cause/remedialactionaredescribedonPages23–27.

Query fault memory F1 – F5 Condition:Theheaterisswitchedoff.

• Pressckey–>theheaterisswitchedon.

• Pressakeyandkeeppressed, thenpresspkeywithin2seconds. Displayisasfollows: AF=currentfault 3digitnumber=faultcode cflashes.

• Pressfkeyonceorseveraltimes,faultmemorypositionsF1–F5aredisplayed.

Cancel the control box lock and simultaneously delete the fault memoryCondition:Anelectricalconnectionexistsfromterminal15(ignition)tothemoduletimer,12-pinconnector,chamber10.

• Pressckey Displayisasfollows: thecurrentfaultF15orF50.

• Pressbuttona,keepitdepressedandthenpressbuttonpwithin2seconds.

Themoduletimerisnowinthe“Queryfaultmemory”pro-gram.

• Switchoffignition(terminal15).

• Simultaneouslypressbuttonaandbuttonp,inaddition,switchontheignition(terminal15)andwaituntilthefollow-ingappearsinthedisplay.

Afterignition“ON”thefollowingappearsinthedisplay:

Displayflashes, Heatersymboldoesnotflash

• Switchtheheateroffandon–>thecontrolboxisunlocked,theheaterrestarts.

Afterswitchingtheheateroffandonandrenewedqueryofthefaultmemory,thefollowingappearsinthedisplay:

Displayflashes, Heatersymboldoesnotflash

a–Timep–Presetc–Heate–Reversef–Forward

Please note!

https://eberspacher-russia.ru

Page 21: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

21

Troubleshooting4TP5 radio remote control(OrderNo:221000320100)

Iffaultsoccurwhiletheheaterisrunning,theyaredisplayedwith“Err”afterthemobileunitisactivated.

Afterthediagnosticscable(bl/ws)hasbeenconnectedandthefirstlogshavearrivedatthestationaryunit,thediagnosecanbecarriedoutusingthemobileunitoftheTP5radioremotecontrol.Thecurrentfault“F0”isdisplayed.Thestoredfaults“F1”to“F5”canbequeried.

• Inordertocarryoutthediagnosis,thediagnosticscable(bl/ws)mustbeconnectedtothestationaryunitandtheheatercableharness.Tothisend,pleaserefertoandfollowthecircuitdiagramfortheTP5radioremotecontrolandtheheater.

• Ifthediagnosticscable(bl/ws)isnotconnected,the“Diag-nosis”menuisblocked.

• Notonlythedefectivecomponent,butalsoadefectivecur-rentcircuitresultsinafaultbeingdisplayed.

• InheaterswithconnectedairpressuresensortheTP5radioremotecontrolcannotbeusedtoperformdiagnoses.ThediagnosticsunitortheEDiTHdiagnosticstoolmustbeusedtoperformthediagnosis.

Thefaultmemoryofthe„airpressuresensor“canbereadoutusingtheEDiTHdiagnosticstoolonly.

• Faultcode,faultdescription,cause/remedialactionaredescribedonPages23–27.

Buttontoactivate/deactivatethemobileunit

Buttonforforwardtimesetting

Buttonforbackwardtimesetting

Buttonforactivatingthepossiblesettings

Buttonforswitchingheat/ventilateON/OFF; Activate/deactivatepreselectedtime

Enquire / delete fault memoryUsethe keytoactivatethemobileunit.Switchontheheaterwiththe key.Pressthe keytwicetoopentheTimesettingmenu–thetimeflashesinthedisplay.

Pressthe keyforapprox2sec–untilthefollowingap-pearsinthedisplay:

Press key.Press key.Press keytwice.Press key.

Malfunctioninheater: Heaterhasnomalfunction:

Usethe and buttonstocallupthefaultmemoryposi-tions1to5.

Delete fault memory / Cancel the control box lockUsethe keytodeletethefaultmemory.

Toconfirm,pressthe keyforapprox2secuntil lightsupinthedisplay–faultmemoryisdeleted.

Please note!

https://eberspacher-russia.ru

Page 22: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

22

The following actions are possible• Callupfaultmemory. CallupthefaultmemorypositionsF1–F5with or .

• Callupfaultmemoryagain. Brieflypress and simultaneously.

• Deletefaultmemory (displaydEL) Press .

Press again.

The diagnosis is completed.

Switch off heater.

Enquire / delete fault memoryActivatemobilepart/timer(seeEasyStartR+/EasyStartToperatinginstructions)

Confirmsymbol with .

Heater is switched on.

Confirmoperatingtimewith .

Brieflypress and simultaneously.

Troubleshooting4EasyStart R+ radio remote control(Order-No.:221000328000)

EasyStart T timer(Order-No.:221000328800)

Iffaultsoccurwhiletheheaterisrunning,theyaredisplayedwith“Err”afterthemobileunitortimerisactivated.

Thecurrentfaultisdisplayed.Thestoredfaults“F1”to“F5”canbequeried.

• Inordertocarryoutthediagnosis,thediagnosticscable(bl/geatheaterconnector,bl/wsatcableharnessconnector)mustbeconnectedtothestationaryunitandtheheatercableharness.Tothisend,pleaserefertoandfollowthecircuitdiagramfortheradioremotecontrolandtheheater.

• Ifthediagnosticscableisnotconnected,the“Diagnosis”menuisblocked.

• Notonlythedefectivecomponent,butalsoadefectivecur-rentcircuitresultsinafaultbeingdisplayed.

• Theheaterdiagnosiscanalsobeperformediftheairpres-suresensorisconnected.

Thefaultmemoryofthe„airpressuresensor“canbereadoutusingtheEDiTHdiagnosticstoolonly.

• Faultcode,faultdescription,cause/remedialactionaredescribedonPages23–27.

Backcontrolkey

Nextcontrolkey

ON/OFFactivationkeymobileunit/timer

OKkey(symbolselection/confirminput)

Please note!

https://eberspacher-russia.ru

Page 23: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

23

Troubleshooting4Fault codeDisplay

Fault description Comments• Remedial action

000 Nofaults ——

004 Warning:Shortcircuitincontrolbox,freshairoutput

• DisconnectconnectorS1/B1attheheaterandattheconnectorB1,PIN16checkthecableuptothefreshairfanrelayforshortcircuittonegative,ifok—>replacecontrolbox.

005 Warning:Shortcircuitincontrolbox,caralarmoutput

• DisconnectconnectorS1/B1attheheaterandattheconnectorB1,PIN15checkthecableuptotherelayisolatingswitchorburglaralarmsysteminputforshortcircuittonegative,ifok—>replacecontrolbox.

006 Warning:Inexplicableatmosphericaltitudeinformation(Displayonlyifheaterslabelled“H-Kit”onthenameplate.)

Controlboxhasnotreceivedanyexplicablealtitudeinformation.• ReadoutfaultmemoryintheairpressuresensorusingtheEDiTHdiagnos-

ticstoolandcorrectfault.

009 Cut-offADR ADRshutdownduetosignalchangefrom(+)to(–)atconnectorS1,PIN13(D+)orplussignalatconnectorS1,PIN14(HA+).

010 Overvoltage–cut-off Overvoltageappliedtocontrolboxforatleast20secondswithoutinterruption–heaternotworking.• DisconnectconnectorS1/B1attheheater,startthevehicle’sengine,

measurethevoltageatconnectorB1betweenPIN1(cable2.52rt)andPIN10(cable2.52br).

Airtronic12volt–voltage>16volt—>checkgeneratorregulator Airtronic24volt–voltage>32volt—>checkgeneratorregulator

011 Undervoltage–cut-off Undervoltageappliedtocontrolboxforatleast20secondswithoutinterrup-tion–heaternotworking.• DisconnectconnectorS1/B1attheheater,thevehicle’sengineisswitched

off,measurethevoltageatconnectorB1betweenPIN1(cable2.52rt)andPIN10(cable2.52br).

Themeasuredvalueandthevoltageatthebatteryshouldbethesame. Incaseofavoltagedrop,checkthefuses,thesupplycables,thenegative

connectionsandthepositivesupportpointonthebatteryforcorrosionandcorrectcontact.

012 Overheatingattheoverheatingsensor Temperatureoftheoverheatingsensortoohigh.• Checkhotairpipesforblockage—>removeblockage.• Sumofthecomponentratingsofair-conductingpartsistoolarge—>

Checkairsystem,ifnecessaryre-lay–forcomponentratings,pleaserefertoadditionalpartscatalogue.

• Checkoverheatingsensor,fordiagramandtableofvaluespleaserefertoPage32,ifok—>measurefuelquantity,seePage36.

013 Overheatingattheflamesensor Flamesensorsignalstemperatureatheatexchangeristoohigh.• Checkhotairpipesforblockage—>removeblockage.• Sumofthecomponentratingsofair-conductingpartsistoolarge—>

Checkairsystem,ifnecessaryre-lay–forcomponentratings,pleaserefertoadditionalpartscatalogue.

• Checkflamesensor,ifok—>checkoverheatingsensor,ifoverheatingsensordefective—>replacecombinationsensor,ifoverheatingsensorok—>measurefuelquantity,seePage36,fordiagramandtableofvaluesforflamesensorandoverheatingsensorpleaserefertoPage32.

014 Temperaturedifferencebetweenflamesensorandoverheatingsensortoolarge

Temperaturedifferencebetweenflamesensorandoverheatingsensortoolarge• Checkhotairpipesforblockage—>removeblockage.• Sumofthecomponentratingsofair-conductingpartsistoolarge—>

Checkairsystem,ifnecessaryre-lay–forcomponentratings,pleaserefertoadditionalpartscatalogue.

• Checkflamesensor,ifok—>checkoverheatingsensor,ifoverheatingsen-sordefective—>replacecombinationsensor,ifoverheatingsensorok—>measurefuelquantity,seePage36,iffuelquantityok—>replacecontrolbox.Fordiagramandtableofvaluesforflamesensorandoverheatingsen-sor,seePage32.

https://eberspacher-russia.ru

Page 24: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

24

Troubleshooting4Fault codeDisplay

Fault description Comments• Remedial action

015 Operatinglock-out Thefaultcode015isdisplayed,iftheheaterwasswitchedbackonafterthefaultcodedisplay017.

Thehardwarethresholdvaluefortheoverheatingsensorhasbeenexceeded—>thecontrolboxislocked.

• Replacecontrolbox.

017 Overheating Thehardwarethresholdvaluefortheoverheatingsensorhasbeenexceeded,becausethecontrolboxfailedtorecognisethefaultcode012or013–>thecontrolboxislocked.Iftheheaterisswitchedonagain,thefaultcode015isdisplayed.• Replacecontrolbox.

018 Startingenergyoftheglowplugistoolow(Displayonlyifheaterslabelled“H-Kit”onthenameplate.)

• Checkglowplug(seefaultcode020and021),ifok• Checkglowplugcableharnessforcorrectlayinganddamage,ifok—>

checkcableharnessforcontinuity,ifok—>replacecontrolbox.

019 Ignitionenergytoolow • Checkglowplug(seefaultcode020and021),ifok• Checkglowplugcableharnessforcorrectlayinganddamage,ifok—>

checkcableharnessforcontinuity,ifok—>replacecontrolbox.

020

021

Glowplug–interruption

Glowplug–shortcircuit,overloadorshortcircuitafternegative

• Checkglowplugforfunctionandcontinuityatambienttemperature20°C. 12voltheater–0.42upto±0.7 24voltheater–1.2upto±2.0

• Ifthevaluesareok—>checkglowplugleadharnessfordamageandcon-tinuity,ifok—>replacecontrolbox.

022 * Glowplug,output(+)–shortcircuitafterUB(batteryvoltage)

• Checkglowplugleadharnessforcorrectlayinganddamage,ifok—>checkleadharnessforcontinuity,ifok—>replacecontrolbox.

025 * Diagnosticscablebl/ws–shortcircuit–afterUB(batteryvoltage)

Faultcodedisplayisnotpossible.Thisfaultcodecannotbereadoutfromthefaultmemoryuntilthefaulthasbeencorrected.• Checkdiagnosticscableforcorrectlayingandpossibledamage.

031 Blower–interruption • Checkthattheleadharnessoftheblowermotorhasbeencorrectlylaidandcheckfordamage,ifok—>removeleadharnessatcontrolboxandcheckforcontinuity,ifok—>replacecontrolbox.

032 Blowermotor–shortcircuitafternegative

Please note!

Ensurecompliancewiththetestvolt-age(seepage12).Thecomponentisdestroyedifthevoltagevalueisexceeded.Ensure the power pack has ad-equate short-circuit resistance – min 20 A.

• Carryoutfunctionaltestontheblowermotor,todothisremovethecon-nectorfromthecontrolbox.Applyatestvoltage(seepage12)totheblow-ermotorandmeasurethecurrentintensityafter40sec.

Currentintensity<6.5A–blowermotorok–>replacecontrolbox. Currentintensity>6.5A—>replaceblower.• Checkwiringforshortcircuit.

033 Blowermotorwon’trotateorshortcircuitafternegative

Please note!

Ensurecompliancewiththetestvolt-age(seepage12).Thecomponentisdestroyedifthevoltagevalueisexceeded.Ensure the power pack has ad-equate short-circuit resistance – min 20 A.

Speeddeviation>10%fromsetpointvalueforlongerthan30seconds.Useanon-contactr.p.m.countertomeasurethespeedofthecombustionair

fan(seepage12fortestspeedandtestvoltage).• Speedtoolow: Blowerblocks–checkblowerforfreerunning,ifnecessaryremoveforeign

body,ifok—>checkblower(seefaultcode032).• Speedtoohigh: – Magnetmissingfromblowerimpeller—>replaceblower. – Speedsensorincontrolboxisdefective—>replacecontrolbox.• Checkwiringforshortcircuit.

* Thisfaultcodeorohmicvalueisvalidforanewgenerationcontrolboxonly.Thisdiffersfromthecontrolboxtodatebyitscableloomwrappedincabletapeandbyatemperaturesensormountedontheside,whichbecomesvisiblewhenthecoverisremoved.

https://eberspacher-russia.ru

Page 25: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

25

Troubleshooting4Fault codeDisplay

Fault description Comments• Remedial action

034 * Blowermotor,outlet(+)shortcircuitafterUB(batteryvoltage)

• Checkthattheleadharnessoftheblowermotorhasbeencorrectlylaidandcheckfordamage,ifok—>removeleadharnessatcontrolboxandcheckforcontinuity,ifok—>replacecontrolbox.

047 Meteringpump–shortcircuitoroverload

• Removeconnectorfromthemeteringpump,ifthefaultcode048(inter-ruption)isdisplayedthemeteringpumpisdefective—>replacemeteringpump.

• Ifthefaultcode047continuestobedisplayed,disconnectconnectorS1/B1attheheater,andattheconnectorB1,PIN5checkthecable12gn/rtuptothemeteringpumpforshortcircuittonegative(PIN10),ifok–>replacecontrolbox.

048 Meteringpump–interruption • Disconnectconnectorfrommeteringpumpandmeasuretheresistancevalueofthemeteringpump(seePage12forvalues),ifresistancevalueok,re-connectthecableloomtothemeteringpump.

• DisconnectconnectorS1/B1attheheaterandmeasuretheresistancevalue(seePage12)betweenPIN5andPIN10,ifok—>replacecontrolbox.

049 * Meteringpumpoutlet(+)Shortcircuit–afterUB(batteryvoltage)

• Checkthattheleadharnessofthemeteringpumphasbeencorrectlylaidandcheckfordamage,ifok—>removeleadharnessandcheckforconti-nuity,ifok—>replacecontrolbox.

050 Toomanyfailedstartattempts(opera-tinglock-out)

Thecontrolboxlocksaftertoomanyfailedstartattempts(max.255startat-tempts).• Unlockthecontrolboxbydeletingthefaultmemorywiththetimer,thedi-

agnosticunit,EDiTHdiagnostictool,theTP5radioremotecontrol/EasyS-tartR+andtheEasyStartTtimer.

051 Flamedetectedwhenswitchingon If,afterbeingswitchedon,theresistancevalueoftheflamesensoris1274(>70°C)theheater’sfanrunsforapprox15mintocooldown,iftheresist-ancedoesnotfallbelowtheaforementionedvaluewithin15mintheheaterisswitchedoff.

• Checkflamesensor,seePage32fordiagramandtableofvalues,ifok—>replacecontrolbox.

052 Safetytimeexceeded Noflamedetectedwithinthestartphase.• Checkexhaustandcombustionairsystem.• Checkfuelsupply/measurefuelquantity,seePage36.• Checksparkplug(seefaultcode020and021)• Checkflamesensor,diagramandtableofvalues,seePage32,

ifok—>replacecontrolbox.

053

054

055

056

Flamecutoutinthe

“POWER”controlstage

“HIGH”controlstage

“MEDIUM”controlstage

“LOW”controlstage

Theheaterhasignited(flamedetected)andsignalsflamecutoutduringapowerstage.

• Checkexhaustandcombustionairsystem.• Checkfuelsupply/measurefuelquantity,seePage36.• Checkflamesensor,diagramandtableofvalues,seePage32,

ifok—>replacecontrolbox.

057 Flamecutoutfromstartphase(Displayonlyifheaterslabelled“H-Kit”onthenameplate.)

Aflamecutoutwasdetectedduringthestartphase..• Checkexhaustandcombustionairsystem.• Checkfuelsupply/measurefuelquantity,seePage36.• Checkglowplug(seefaultcode020and021).• Checkflamesensor,diagramandvaluestable,seepage32,

ifok—>replacecontrolbox.

060 Externaltemperaturesensor–interruption

• DisconnecttheconnectorS4/B4oftheexternaltemperaturesensorandmeasuretheresistancevalueatconnectorB2,fordiagramandtableofva-luesseePage12,iftemperaturesensorok,reassembleconnectorS4/B4.

• DisconnectconnectorS1/B1attheheaterandmeasuretheresistancevalueinconnectorhousingB1betweenPIN6andPIN12.Ifinterruptedtheohmicvalueis>7175/3k*.Ifresistancevalueok—>replacecontrolbox.

* Thisfaultcodeorohmicvalueisvalidforanewgenerationcontrolboxonly.Thisdiffersfromthecontrolboxtodatebyitscableloomwrappedincabletapeandbyatemperaturesensormountedontheside,whichbecomesvisiblewhenthecoverisremoved.

https://eberspacher-russia.ru

Page 26: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

26

Troubleshooting4Fault codeDisplay

Fault description Comments• Remedial action

061 Externaltemperaturesensor–shortcircuit

• DisconnectconnectorS4/B4oftheexternaltemperaturesensor,iffaultcode060isdisplayed—>checkexternaltemperaturesensor,diagramandtableofvalues,seePage32.Iftemperaturesensorok—>checkconnec-tioncables0.5grand0.5br/wsforshortcircuit,ifok,reassemblethecon-nectorS2/B2.

• DisconnectconnectorS1/B1attheheaterandmeasuretheresistancevalueinconnectorhousingB1betweenPIN6andPIN12.Incaseofshortcircuittheohmicvalueis<486/<800*.

Iferror061continuestobedisplayed—>replacecontrolbox.

062 Controlunit–interruption

Please note!

Refertonotesondiagnosiswithmini-controlleronpage14.

Heaterrunsin„High“controlstageonly• Removeconnectoratthecontrolunitandmeasuretheresistancevalueof

thesetpointpotentiometer,forconnectorpinsseePage42onwards.Iftheresistancevalueisok,reconnectconnectoratthecontrolunit.

• DisconnectconnectorS1/B1attheheater,measuretheresistancevaluebetweenPIN6andPIN7inconnectorhousingB1,ifresistancevalueok—>replacecontrolbox.Resistancevalueincaseofinterruption>7175 />3k *.Normalvalues:seepage12.

063 Controlunit–shortcircuit

Faultrecognitiononlyworksinhea-tingmode.If,ontheotherhand,theshortcircuithasalreadyoccurredandthentheheaterisswitchedon,„Venti-lation“isactive(notafaultcode).

• Ifthe“Ventilate”switchisinstalled,disconnectitandcheckitworks.Ifnotok—>replaceswitch.

• Disconnectconnectoratcontrolunit,iferrorcode062isdisplayed,replacethecontrolunit.Ifcontrolunitok,checkconnectioncables0.5gr/rtand0.5br/wsforshortcircuit,ifok—>reconnectconnectoratcontrolunit.

• DisconnectconnectorS1/B1attheheater,iftheerror063continuestobedisplayed—>replacecontrolbox.Resistancevalueincaseofshort-circuit<486 / <800 *.Normalvalues:seepage12.

064 Flamesensor–interruption • Dismantlecontrolboxanddisconnectgreenconnectorfromcontrolbox.Checkflamesensor,diagramandtableofvalues,seePage32,ifflamesen-sorok—>replacecontrolbox.Resistancevalueincaseofinterruption>7175 />3k *.

065 Flamesensor–shortcircuit Dismantlecontrolbox,removegreenconnectorfromcontrolbox,iferror064isdisplayed—>replacecombinationsensor.

Iferror065continuestobedisplayed—>replacecontrolbox. Resistancevalueincaseofshortcircuit<486 /<500*,seealsodia-

gramonPage32.

071 Overheatingsensor–interruption • Dismantlecontrolbox,disconnectblueandgreenconnectorsfromcontrolbox.MeasureresistancevalueatblueconnectorPIN1(cable0.52bl)andatgreenconnectorPIN2(cable0.52br/ws),ifok,—>replacecontrolbox.

Resistancevalueincaseofinterruption>223k />1600k *,seealsodiagramonPage32.

072 Overheatingsensor–shortcircuit • Dismantlecontrolbox,removeblueconnectorfromcontrolbox,iferror071isdisplayed—>replacecombinationsensor.

Iferror072continuestobedisplayed—>replacecontrolbox. Resistancevalueincaseofshortcircuit<183 /<95*,seealsodia-

gramonPage32.

074 * Controlboxdefective • Overheatingthresholdvalueisnotdetectedbycontrolbox—>replacecon-trolbox.

090 Controlboxdefective(internalfault) • Replacecontrolbox.

091 Externalinterferencevoltage • Controlboxfaultduetointerferencevoltagesfromthevehicle’selectricalsystem.Possiblecauses:

Poorbattery,charger—>removeinterferencevoltage.

092 Controlboxisdefective(ROMerror) • Replacecontrolbox.

093 * Controlboxdefective • Replacecontrolbox.

* Thisfaultcodeorohmicvalueisvalidforanewgenerationcontrolboxonly.Thisdiffersfromthecontrolboxtodatebyitscableloomwrappedincabletapeandbyatemperaturesensormountedontheside,whichbecomesvisiblewhenthecoverisremoved.

https://eberspacher-russia.ru

Page 27: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

27

Troubleshooting4Fault codeDisplay

Fault description Comments• Remedial action

094 Controlboxdefective(EEPROM-Fehler)

• Replacecontrolbox.

095 * Controlboxdefective • Replacecontrolbox.

096 Internaltemperaturesensordefective • Replacecontrolboxoruseanexternalroomtemperaturesensor..

097 Controlboxdefective • SReplacecontrolbox.

098 * Controlboxdefective • Replacecontrolbox.

099 * Toomanyresetsinsequence

Transistorerrorincontrolbox

• Voltageshort-term<5–6volt(for12volt)or<7–8volt(for24volt). Incaseofavoltagedrop,checkthefuses,thesupplycables,thenegative

connectionsandthepositivesupportpointonthebatteryforcorrosionandcorrectcontact.

Testcontrolboxwithtestingdevice,ifok—>checkleadharnessoftheex-ternalcomponentshasbeencorrectlylaidandcheckfordamage,ifok—>checkleadharnessforcontinuity,ifok—>replacecontrolbox.

Air pressure sensor fault code displayFault code display

Fault description Comments• Remedial action

0 Nofaults —

11 Communicationloss Interruptionofthediagnosticscablebetweenthecontrolbox(heater)andtheairpressuresensor• Checkwiringandplug-inconnections

12 Noaltitudeadjustment Controlbox(heater)doesnotsupportaltitudeoperationwiththeairpressuresensor• Useacontrolbox(heater)whichsupportsaltitudeadjustment

13 Airpressuresensorfault Theairpressuresensorisdefective• Replacetheairpressuresensor

* Thisfaultcodeorohmicvalueisvalidforanewgenerationcontrolboxonly.Thisdiffersfromthecontrolboxtodatebyitscableloomwrappedincabletapeandbyatemperaturesensormountedontheside,whichbecomesvisiblewhenthecoverisremoved.

https://eberspacher-russia.ru

Page 28: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

28

Repair instructions

Thepermittedrepairworktotheheaterisdescribedinthe“RepairInstructions”chapter.Ifextensiverepairsarenecessary,itmakessensetodismantletheheater.

Theheaterisassembledinthereverseorder,ifapplicablenotadditionalinstructions.

Aftercompletingalltheworkontheheater,youmustcarryoutafunctionalcheck(seePage4).

Always observe the following safety instructions before working on the heater:

Danger!Risk of injury, burns and poisoning!• Alwaysswitchofftheheaterbeforehandandleaveittocool.• Disconnectthebattery.• Theheatermustnotbeoperatedinclosedroomssuchas

garagesorworkshops. Exception: Exhaustsuctionavailabledirectlyattheentrytotheexhaust

pipe.

Caution!• Thesealsofdismantledcomponentsmustberenewed.• Duringrepairwork,checkallcomponentsfordamageandif

necessaryreplace.• Checkconnectorcontacts,plug-inconnectionsandcables

forcorrosionanddamageandifnecessaryrepair.• OnlyeveruseEberspächersparepartsifreplacementsare

necessary.• Operationortheafterrunningoftheheatermayonlybe

stoppedinanemergency(see“EMERGENCYOFF”Page8)byinterruptingthebatterycurrent(riskofheateroverheat-ing).

Repairinstructions5Special tool

AMP release tool

TheAMPreleasetoolisusedtoreleaseplug-incontactsinaconnectorhousing.

ThisreleasetoolcanbeordereddirectlyfromAMP.

• ForMicroTimer: AMPOrderNo.0-0539960-1

• ForJunior-Power-Timer: AMP-Bestell-Nr.1-1579007-6

Please note!

https://eberspacher-russia.ru

Page 29: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

29

Assembly drawing Airtronic / Airtronic M

Partslist

1 Combustionairfan 2 Seal–combustionairfan/heatexchanger 3 Combustionchamber 4 Seal–combustionchamber/heatexchanger 5 Heatexchanger 6 Controlbox 7 Combinationsensor(overheating/flamesensor)with

assemblytool

8 Bracket 9 Glowplug,withspecialtool(SW12)10 Lining–glowplugsocket,withassemblytool11 Cover12 Outershell(bottomsection)13 Flangeseal14 Sleeve(forpetrolonly)

Repairinstructions5

https://eberspacher-russia.ru

Page 30: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

30

Repair step 1Remove the heater’s cover (seeFigure1)

Unlockbothfasteningclips,liftthecoverandremovefromthefront.

Theheater’scovermustberemovedforallrepairsteps.Ifnecessary,waituntiltheunithascooleddown.

Cableharnessoutletfromthehousingoptionallyonleftorright-handside.

1. 2.

Figure1

Cover Fasteningclips

Repair step 2Dismantle control box (seeFigure2)

• Repairstep1.• Unscrewfixingscrew,• Presstogethertheretainingclamps.• Removethecontrolboxfromabove.• Unclipcablesfromholderoncontrolbox (Notethepositionofthecables).• Pullgrommetoutoftheoutershell(bottomsection).• Pullconnectoroutofcontrolbox,thecontrolboxcannow

beremoved.

Whenassemblingthecontrolbox,ensurethecablesareclip-pedintotheholderonthecontrolboxandtheconnectorsarepluggedintothecontrolbox(unmistakeable).TighteningtorqueofthefixingscrewItem:2+0.2Nm

Figure2

Fixingscrew Retainingclamp Controlbox Grommet

Check control box

TheEDiTHdiagnostictoolisrequiredtocheckthecontrolboxwhenitisdismantled.Forconnection,useandOrderNo.,seePage19.

5 Repairinstructions

Please note!

Please note!

https://eberspacher-russia.ru

Page 31: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

31

Repair step 3Dismantle glow plug (seeFigure3)

Important!Safety instruction for installation of the rubber grommetTopreventleaks,inserttherubbergrommetpreciselyintheglowplugholeintheheatexchanger.Failuretocomplywiththisinstructioncanresultinpersonalinjuriesaswellasmalfunctioningordamagetotheheater.

• Repairstep2.• Disconnectconnectorfrom“glowplug”cableloomoncon-

trolbox.• Removerubbergrommetandunscrewtheglowplugusing

thespecialtool(SW12). (Thespecialtoolisincludedwiththeglowplug).

Tighteningtorqueforglowplug:6+0.5Nm

Specialglowplugtool

Please note!

Withtheglowplugdismantled,visuallycheckthesocketliningoftheinstalledglowplugfordirt.Iftheliningishighlysoiledanditssurfaceclosed,renewthelining.

Figure3

Glowplug Connectorfromglowplugcableloom Rubbergrommet

Removing the lining (see Figure 4)

Uselongnoseplierstopulltheliningoutofthesocketfromabove.Blowoutthesocketwithcompressedairandifnecessarycleanthesideventhole.

Usethespecialtooltoinstallthenewlining.Thespecialtoolisincludedwiththelining.Pushtheliningonthetool.Pushinthetooltogetherwiththelininguptothelimitstop.

Figure4

Specialtool Lining

5

Repairinstructions

https://eberspacher-russia.ru

Page 32: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

32

Repair step 5 Dismantle combination sensor (overheating / flame sen-sor) (seeFigure5)

• Repairstep2.• Removebothconnectorsfromthe“combinationsensor”

cableloomatthecontrolbox.• Unlockbracketfromcombinationsensor.• Removethecombinationsensor.

Figure5

“Combinationsensor”cableloom Bracket,unlocked

Check combination sensor

Theexternaltemperaturesensormustbecheckedwithadigi-talmultimeter.Replacetheoverheatingorflamesensoriftheresistancevalueisnotthesameasthecurveinthediagramorthetableofvalues.

Table of overheating sensor values

Temperature °C Resistance k min. max. – 40 1597.00 1913.00 – 20 458.80 533.40 0 154.70 175.50 20 59.30 65.84 40 25.02 28.04 60 11.56 13.16 80 5.782 6.678 100 3.095 3.623 120 1.757 2.081 140 1.050 1.256 160 0.6554 0.792 180 0.4253 0.5187 200 0.2857 0.3513

Table of flame sensor values

Temperature °C Resistance min. max.– 40 842.7 825.9 859.6– 20 921.6 803.2 940.0 0 1000.0 980.0 1020.0 20 1077.9 1056.4 1099.5 40 1155.4 1132.3 1178.5 60 1232.4 1207.8 1257.1 80 1308.9 1282.8 1335.1 100 1385.1 1357.4 1412.8 120 1460.7 1431.5 1489.9 140 1535.8 1505.1 1566.6 160 1610.5 1578.3 1642.8

Res

ista

nce

(kO

hm)

Temperature(°C)

5

Notethemax.temperatureof320°Cforthetest.

Temperature(°C)

Res

ista

nce

(Ohm

)

Overheating sensor Flame sensor

Repairinstructions

Please note!

https://eberspacher-russia.ru

Page 33: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

33

Sketch2

Specialtool–onlyrequiredforAirtronic Combinationsensor

Figure6

Specialtool–onlyrequiredforAirtronic Combinationsensor

Repair step 6 Install combination sensor (overheating / flame sensor)(seeFigure6,7andSketch2–4)

•Repairstep2.• ForAirtronic(assemblywithspecialtool,seeSketch2) Pushthespecialtoolaontothecombinationsensorb.Use

thespecialtooltopositionthecombinationsensorontheheatexchanger,thespecialtoolslidesontheheatexchang-eruntilthecombinationsensorhitsthecollar(installationpositionofthecombinationsensor).

Lockthecombinationsensor’sbracketandremovethespecialtool.Thenalwayscheckthatthecombinationsen-sorsitsflatontheheatexchanger.Ifnecessary,useaidssuchasamirrorandlamp.

Laythe“combinationsensor”cableloomalongthebracket,throughthebracketeyeletuptothecontrolboxandcon-nect.

• ForAirtronicM(assemblywithoutspecialtool) Placethecombinationsensorontheheatexchanger;itis

importanttoensurethecombinationsensorsitsflatontheheatexchanger.

Lockthecombinationsensor’sbracketandcheckagainthatthecombinationsensorissittingflatontheheatex-changer.

Laythe“combinationsensor”cableloomalongthebracket,throughthebracketeyeletuptothecontrolboxandcon-nect.

Sketch4

Bracket Combinationsensor

Figure7

Bracket,locked “Combinationsensor”cableloom Specialtool–onlyrequiredforAirtronic

Circuit diagram for combination sensor (overheating sensor / flame sensor)

Sketch3

NTC50KΩ=overheatingsensorPT1000=flamesensor

Connectorblue

Connectorgreen

5 Repairinstructions

https://eberspacher-russia.ru

Page 34: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

34

Repair step 7 Dismantle heat exchanger (seeFigure8andSketch5)Dismantle combustion air fan (seeFigure8andSketch5)

• Repairstep2.• Removeflangeseal.Removeheaterfromtheoutershell

(bottomsection). Unscrewthe4fixingscrewsfromthecombustionairfan. Removethecombustionairfanandthesealfromtheheat

exchanger.

Caution!Wheninstallingthecombustionairfanthesealmustalwaysberenewed.

Tightenthe4fixingscrewsofthecombustionairfan–intheordershowninSketche–withatighteningtorqueof4+0.5Nm. Figure8

Combustionairfan Heatexchanger Fixingscrew

Sketch5

1–4 Tightenthefixingscrewsinthisorderwithatightening

torqueof4+0.5Nm

5

5 Alwaysrenewthesealbetweenthecombustionairfanandtheheatexchanger.

5

2

4

3

1

Repairinstructions

https://eberspacher-russia.ru

Page 35: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

35

Repair step 8Dismantle combustion chamber (seeFigure9andSketch6)

• Repairstep3.• Repairstep7.• Unscrewthefixingscrews. IntheAirtronic=3fixingscrews, intheAirtronicM=4fixingscrews.• Pulloutthecombustionchamberfromthefrontandremove

theheatexchanger’sseal.

Caution!Whenassemblingthecombustionchamber,alwaysrenewtheseal,whichisincludedwiththesparepart.

Tightenthefixingscrewsofthecombustionchamberwithatighteningtorqueof5+0.5Nm

Iftheheatexchangerisreplacedthecombinationsensor(overheatingsensor/flamesensor)mustbedismantledandfittedonthenewheatexchanger(seeRepairstep6,Page33).

Sketch6

1Combustionchamber2Alwaysrenewthesealbetweenthecombustionchamber

andtheheatexchanger.3Heatexchanger

4Fixingscrew Airtronic=3fixingscrews AirtronicM=4fixingscrews

Figure9

Combustionchamber Heatexchanger Fixingscrew Airtronic=3fixingscrews AirtronicM=4fixingscrews

5

4

1

2

3

Repairinstructions

Please note!

https://eberspacher-russia.ru

Page 36: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

36

Measuring the fuel quantity

1. Preparation

Removethefuelpipeattheheaterandinsertameasuringcylinder(size10ml).Switchontheheater,ifthefuelisuniformlypumped(beginsapprox.60secafterbeingswitchedon),thefuelpipeisfullandvented.Switchoffheaterandemptymeasuringcylinder.

Forprecisefuelmeasurementatleast11volt/22voltormaximum13volt/26voltshouldbeappliedtothecontrolboxduringthemeasurement.

2. Measurement

Thefuelbeginstobepumpedapprox.60secafterswitchingontheheater.Holdthemeasuringcylinderatglowpluglevelduringthemeasurement.

Airtronic Afterapprox.90secofthefuelbeingpumpeditisautomati-callyswitchedoff.

Caution!Switch off heater,asotherwiseitwillstartupagain.

Readoffthequantityoffuelinthemeasuringcylinder.

Airtronic MAfterapprox.105secofthefuelbeingpumpeditisautomati-callyswitchedoff.

Caution!Switch off heater,asotherwiseitwillstartupagain.

Readoffthequantityoffuelinthemeasuringcylinder..

Ifthemeasuredfuelquantityliesoutsidethevaluesgivenbelow,themeteringpumpmustbereplaced.

1 Heater2 Meteringpump

Check fuel supply

Beforemeasuringthefuelquantity,checkthefollowingpointsinthefuelsupply.

• Checkthescreeninthemeteringpump.• Checkthelayingofthefuelpipes.• Checkfuelpipesforleaks.• Checkandtightenthehoseconnections.• Isthefuelremovalinstalledaccordingtothedetailsinthe

technicaldescription?

5

3 Measuringcylinder(size10ml)4 Disconnectfuelpipeatheaterandinsertinameasuringcylinder.

1

2

3

4

Table of values – fuel quantity

Heater Fuel Fuel quantity

Minimal Maximal

Airtronic diesel 3,5ml/90sec 4,3ml/90sec

AirtronicM petrol 6,8ml/105sec 7,6ml/105sec

AirtronicM diesel 5,0ml/105sec 6,0ml/105sec

Bitte beachten!

Repairinstructions

https://eberspacher-russia.ru

Page 37: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

37

Circuitdiagram6Overview of the parts lists and circuit diagrams

PartslistcircuitdiagramAirtronic/AirtronicM................................................................................................................................ 38CircuitdiagramAirtronic/AirtronicM.............................................................................................................................................. 39 Thiscircuitdiagramisforheaterswithonediagnosticscableandacontrolboxcableloomwhichisfirmlyencapsulated.CircuitdiagramAirtronic/AirtronicM.............................................................................................................................................. 40 Thiscircuitdiagramisforheaterswith2diagnosticscableandwhosecontrolboxcableloomiswoundwithcabletape.

Partslistcontrolunits..................................................................................................................................................................... 41Circuitdiagramscontrolunits...................................................................................................................................................42–48

PartslistEasyStartR+/R/Tcontrolunits..................................................................................................................................... 49EasyStartR+circuitdiagram...................................................................................................................................................50–52EasyStartRcircuitdiagram......................................................................................................................................................53–55EasyStartTcircuitdiagram....................................................................................................................................................... 56,57

PartslistcircuitdiagramAirtronic/AirtronicM–ADR..................................................................................................................... 58CircuitdiagramAirtronic/AirtronicM–ADR................................................................................................................................... 59 Thiscircuitdiagramisforheaterswithonediagnosiscableandacontrolboxcableloomwhichisfirmlyencapsulated.CircuitdiagramAirtronic/AirtronicM–ADR................................................................................................................................... 60 Thiscircuitdiagramisforheaterswith2diagnosticscableandwhosecontrolboxcableloomiswoundwithcabletape.

Partslistcontrolunits–ADR.......................................................................................................................................................... 61Circuitdiagramcontrolunits–ADR............................................................................................................................................... 62EasyStartT–ADRcircuitdiagram............................................................................................................................................ 63,64

https://eberspacher-russia.ru

Page 38: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

38

Parts list circuit diagrams Airtronic / Airtronic M

1.1 Burnerengine1.2 Glowplug1.5 Overheatingandflamesensor2.1 Controlbox2.2 Meteringpump2.7 Mainfuse 12volt=20A 24volt=10A2.7.1Fuse,actuation5A5.1 Battery

a) Connectionofcontrolunitandexternalsensoraccord-ingto“controlunits”circuitdiagram

•rt Powersupply,plus–terminal30 •ge Switch-onsignal–S+ •gr Temperature–actualvalue •wsrt Switchofftheanti-theftalarmsystem (ADR–feedbacksignalfortimer) •br Powersupply,minus–terminal31 •blws Diagnosis •grrt Temperature–setpoint •brws Groundconnectionforexternaltempera-

turesensorandtemperaturesetpoint b) Option •Vehiclefancontrol and/or •separatefreshairfan

Thecircuitdiagramsareassignedviatheinstalledcontrolbox:• Controlboxwithonediagnosticscable: Atthe16pinconnectorthediagnosticscablebl/wsiscon-

nectedtochamber8.• Controlboxwith2diagnosticscablesandJEdiagnosis: Atthe16pinconnectorthediagnosticscablebl/wsis

connectedtochamber3,thediagnosticscablebl/geisconnectedtochamber8.

• Insulateunusedcableends.• Connectorsandbushhousingsareshownfromthecable

inletside.

Circuitdiagram6

Cable colours circuit diagramssw = blackws = whitert = redge = yellowgn = greenvi = violetbr = browngr = greybl = blueli = purple

Please note!

https://eberspacher-russia.ru

Page 39: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

39

Circuit diagram – Airtronic / Airtronic M

252069009801APartslistPage38

Circuitdiagram6

Thiscircuitdiagramisforheaterswithadiagnosticscableandwhosecontrolboxcableloomwhichisfirmlyencapsulated.

Please note!

https://eberspacher-russia.ru

Page 40: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

40

Circuit diagram – Airtronic / Airtronic M

Circuitdiagram6

Thiscircuitdiagramisforheaterswith2diagnosticscableandwhosecontrolunitcableloomiswoundwithcabletape.

252069009801BPartslistPage38

Bitte beachten!

https://eberspacher-russia.ru

Page 41: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

41

Circuitdiagram6Parts list circuit diagrams, control units

2.15.1 Temperaturesensor,external(roomtemperature)2.15.9 Temperaturesensor(externaltemperature)3.1.9 Changeoverswitch“heat/ventilate”3.1.11 Controlunit,round3.1.16 Radioremotecontrolbutton3.1.17 MinicontrollerAirtronic3.1.18 ButtonCalltronic3.2.8 Moduletimer(ADR–potentiometer)3.2.12 Timer,mini–12/24volt3.2.14 Lighting,timer,mini–12voltonly3.3.6 RadioremotecontrolstationarypartTP41i3.3.7 RadioremotecontrolstationarypartTP53.3.8 RemotecontrolCalltronic3.8.3 Antenna3.9.1 Diagnosis,JEdiagnosis

a)ConnectioncontrolelementstotheAirtronic •rt Powersupply,plus–terminal30 •ge Switch-onsignal–S+ •gr Temperature–actualvalue •wsrt Switchoffburglaralarm (ADR–feedbackfortimer) •br Powersupply,minus–terminal31 •blws Diagnosis •grrt Temperature–setpoint •brws Groundconnectionforexternaltempera-

turesensorandtemperaturesetpoint b) Terminal15–necessaryforconnectionTP4i c) Lighting,terminal58d) Connection,diagnosticunit e) Connection,externaltemperaturesensor g) Connection,externalheatingbutton h) Connection,radioremotecontrolTP4i j) Connection,temperaturesensor(outsidetemperature) k) Ifconnectingtimerorradioreceiver– Disconnectcablehere l) Connection,change-overswitch“heat/ventilate” option) Initialoperation:Activatechangeoverswitch “heat/ventilate”,thenswitchontheheater. z) Lighting,terminal58

• Insulateunusedcableends.• Connectorsandbushhousingsareshownfromthecable

inletside.

Cable colours circuit diagramssw = blackws = whitert = redge = yellowgn = greenvi = violetbr = browngr = greybl = blueli = purple

Please note!

https://eberspacher-russia.ru

Page 42: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

42

Circuit diagram, control units – part 1

252069009701CPartslistPage41

Circuitdiagram6

https://eberspacher-russia.ru

Page 43: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

43

Circuitdiagram6

252069009701CPartslistPage41

Circuit diagram, control units – part 2

https://eberspacher-russia.ru

Page 44: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

44

Circuit diagram, control units – part 3

252069009702APartslistPage41

Circuitdiagram6

https://eberspacher-russia.ru

Page 45: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

45

Circuit diagram, control units – part 4

252069009702APartslistPage41

Circuitdiagram6

https://eberspacher-russia.ru

Page 46: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

46

Circuit diagram, control units – part 5

252069009704APartslistPage41

Circuitdiagram6

https://eberspacher-russia.ru

Page 47: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

47

Circuit diagram, control units – part 6

252069009704APartslistPage41

Circuitdiagram6

https://eberspacher-russia.ru

Page 48: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

48

Circuit diagram, control units – part 7

PartslistPage41

Circuitdiagram6

252069009703B

https://eberspacher-russia.ru

Page 49: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

49

Circuitdiagram6Parts list circuit diagram control units – EasyStart R+ / R / T

2.15.1 Temperaturesensor(roomtemperature) (includedinscopeofsupplyforEasyStartR+, optionalforEasyStartR/T)2.15.9 Outsidetemperaturesensor(optional)

3.1.7 “OFF”button3.1.9 “Heat/ventilate”switch3.1.11 “Round”controlunit3.1.16 Radioremotecontrolbutton3.1.17 “Minicontroller”controlunit

3.2.15 EasyStartTtimer

3.3.9 RadioremotecontrolEasyStartR(stationaryunit)3.3.10 RadioremotecontrolEasyStartR+(stationaryunit)

3.6.1 Leadharness

3.8.3 Antenna

a) Connectionofcontrolunitsattheheaterc) Terminal58(lighting)d) Parkingventilationwithvehiclefan(optional)e) ConnectionofEasyStartTtimertimerg) Connection“ON/OFF”key (optionale.g.OrderNo.:221000328400)h) Connectionof“Ventilate”viaEasyStartR+x) ADRjumpery) Connectandinsulatecables

•Note heater type!•Thejumperlabelledwithy)inthecircuitdiagrammustalways

beconnected.•Insulateunusedcableends.•Connectorsandbushhousingsareshownfromthecable

inletside.

Assignment of the circuit diagrams for Airtronic heatersThecircuitdiagramsareassignedviatheinstalledcontrolbox:• Controlboxwithonediagnosticscable: Atthe16pinconnectorthediagnosticscablebl/wsiscon-

nectedtochamber8.• Controlboxwith2diagnosticscablesandJEdiagnosis: Atthe16pinconnectorthediagnosticscablebl/wsis

connectedtochamber3,thediagnosticscablebl/geisconnectedtochamber8.

Cable colours circuit diagramssw = blackws = whitert = redge = yellowgn = greenvi = violetbr = browngr = greybl = blueli = purple

Please note!

EasyStart TPinassignmentEasyStartT-connectorS1

1 Terminal 30 (positive) rt 2 S+(switchingonsignal) ge 3 Terminal 31 (negative) br 4 DATcable vi 5 Diagnosis cable (K line) bl/ws 6 Terminal58 gr/sw 7 Temperaturesensor(positive)) gr 8 Temperaturesensor(negative) br/ws 9 –– ––

EasyStart R Pinassignmentatthestationaryunitconnector

1 Terminal31(negative) 2 –– 3 –– 4 DATcable 5 Pushbutton/LED(negative) 6 –– 7 Terminal30(positive) 8 S+(switching on signal) 9 LED(positive)10 Diagnosiscable(Kline))11 Pushbutton(negative)12 ––

EasyStart R+ Pinassignmentatthestationaryunitconnector

1 Terminal31(negative) 2 –– 3 Ventilate(switchingsignal–) 4 DATcable 5 Pushbutton/LED(negative) 6 Temperaturesensor(negative) 7 Terminal30(positive) 8 S+(switchingonsignal) 9 LED(positive)10 Diagnosiscable(Kline)11 Pushbutton(negative)12 Temperaturesensor(positive)

Pin assignments

https://eberspacher-russia.ru

Page 50: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

50

Circuitdiagram6EasyStart R+ control unit circuit diagram(Controlboxwithonediagnosticscable)

PartslistPage49 252069009706B

https://eberspacher-russia.ru

Page 51: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

51

Circuitdiagram6

PartslistPage49 252069009706B

EasyStart R+ control unit circuit diagram(Controlboxwithonediagnosticscable)

https://eberspacher-russia.ru

Page 52: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

52

Circuitdiagram6EasyStart R+ control unit circuit diagram(Controlboxwithtwodiagnosticscables)

PartslistPage49 252361009701B

https://eberspacher-russia.ru

Page 53: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

53

Circuitdiagram6EasyStart R control unit circuit diagram(Controlboxwithoneortwodiagnosticscables)

PartslistPage49 252361009705B

https://eberspacher-russia.ru

Page 54: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

54

Circuitdiagram6EasyStart R control unit circuit diagram(Controlboxwithtwodiagnosticscables)

PartslistPage49 252361009702B

https://eberspacher-russia.ru

Page 55: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

55

Circuitdiagram6EasyStart R control unit circuit diagram(Controlboxwithonediagnosticscable)

PartslistPage49 252069009707B

https://eberspacher-russia.ru

Page 56: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

56

Circuitdiagram6EasyStart T control unit circuit diagram(Controlboxwithonediagnosticscable)

PartslistPage49 252069009708

https://eberspacher-russia.ru

Page 57: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

57

Circuitdiagram6EasyStart T control unit circuit diagram(Controlboxwithtwodiagnosticscables)

PartslistPage49 252361009703

https://eberspacher-russia.ru

Page 58: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

58

Circuitdiagram6Parts list circuit diagrams Airtronic / Airtronic M – ADR

1.1 Burnerengine1.2 Glowplug1.5 Overheatingandflamesensor2.1 Controlbox2.2 Meteringpump2.7 Mainfuse 12volt=20A 24volt=10A2.7.1Fuse,actuation5A5.1 Battery5.2.1Operatingswitchbatteryd) (operationcontrollede.g.viaignitionlock) EmergencyofffunctionforADR–Item5.2.2–5.55.2.2Isolatingswitchbatteryd)5.3 AuxiliarydriveHA+5.3.1Switch,auxiliarydrive5.5 GeneratorD+

a) Connectionofcontrolunitandexternalsensor correspondingto“controlunits”circuitdiagram •rt Powersupply,plus-terminal30 •ge Switch-onsignal-S+ •gr Temperature-actualvalue •wsrt Switchofftheanti-theftalarmsystem (ADR–feedbacksignalfortimer) •br Powersupply,minus-terminal31 •blws Diagnosis •grrt Temperaturesetpointvalue •brws Groundconnectionforexternal

temperaturesensorandtemperature setpoint

b) Option •Vehiclefancontrol and/or •separatefreshairfan c) WiringforoperationwithADR(hazardousgoodstrans-

portinutilityvehiclesegment,e.g.tanker)

d) Ifonlyoneswitchingelementisusedforitems5.2.1and5.2.2,itisimportanttoensurethatonactivatingthe“openthebatteryisolatingswitch”function(EMERGEN-CYOFFfunctioninADR,etc.),theswitchalwaysbreakscontactimmediately(regardlessoftheheatercondition)andalltheheater’scircuitsaredisconnectedfromthebattery.

• Note heater type! • Thejumperlabelledwithy)inthecircuitdiagrammust

alwaysbeconnected.• Insulateunusedcableends.• Connectorsandbushhousingsareshownfromthecable

inletside.

Assignment of the circuit diagrams for Airtronic heatersThecircuitdiagramsareassignedviatheinstalledcontrolbox:• Controlboxwithonediagnosticscable: Atthe16pinconnectorthediagnosticscablebl/wsiscon-

nectedtochamber8.• Controlboxwith2diagnosticscablesandJEdiagnosis: Atthe16pinconnectorthediagnosticscablebl/wsis

connectedtochamber3,thediagnosticscablebl/geisconnectedtochamber8.

Cable colours circuit diagramssw = blackws = whitert = redge = yellowgn = greenvi = violetbr = browngr = greybl = blueli = purple

Please note!

https://eberspacher-russia.ru

Page 59: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

59

Circuit diagram – Airtronic / Airtronic M – ADR

252069009601BPartslistPage58

Circuitdiagram6

Thiscircuitdiagramisforheaterswithonediagnosticscableandwhosecontrolboxcableloomisfirmlyencapsulated.

Bitte beachten!

https://eberspacher-russia.ru

Page 60: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

60

Circuit diagram – Airtronic / Airtronic M – ADR

Circuitdiagram6

PartslistPage58 252069009601C

Thiscircuitdiagramisforheaterswith2diagnosticscableandwhosecontrolboxcableloomiswoundwithcabletape.

Bitte beachten!

https://eberspacher-russia.ru

Page 61: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

61

Circuitdiagram6Parts list circuit diagrams control unit EasyStart T – ADR

3.1.7 “OFF”button3.1.17 “Minicontroller”controlunit

3.2.15 TimerEasyStartT

a) Connectionofcontrolunitsattheheaterg) Connection“ON/OFF”key (optionale.g.OrderNo.:221000328400)x) ADRjumpery) Connectandinsulatecables

• Thejumperlabelledwithy)inthecircuitdiagrammustalwaysbeconnected.

• Insulateunusedcableends.• Connectorsandbushhousingsareshownfromthecable

inletside.

Assignment of the circuit diagrams for Airtronic heatersThecircuitdiagramsareassignedviatheinstalledcontrolbox:• Controlboxwith2diagnosticscablesandJEdiagnosis: Atthe16pinconnectorthediagnosticscablebl/wsis

connectedtochamber3,thediagnosticscablebl/geisconnectedtochamber8.

• Controlboxwithonediagnosticscable: Atthe16pinconnectorthediagnosticscablebl/wsiscon-

nectedtochamber8.

Parts list circuit diagram control units – ADR

2.15.1 Temperaturesensor,external(roomtemperature)

3.1.11 Controlunit,round3.1.17 MinicontrollerAirtronic

3.2.8 Moduletimer(ADR–potentiometer)

3.9.1 Diagnosis,JEdiagnosis

a) ConnectioncontrolelementstotheAirtronic •rt Powersupply,plus–terminal30 •ge Switch-onsignal–S+ •gr Temperature–actualvalue •wsrt Switchoffburglaralarm (ADR–feedbackfortimer) •br Powersupply,minus–terminal31 •blws Diagnosis •grrt Temperature–setpoint •brws Groundconnectionforexternal

temperaturesensorandtemperature setpoint

b) Terminal15 c) Lighting,terminal58d) Connection,diagnosticunit e) Connection,externaltemperaturesensor

• Insulateunusedcableends.• Connectorsandbushhousingsareshownfromthecable

inletside.

Cable colours circuit diagramssw = blackws = whitert = redge = yellowgn = greenvi = violetbr = browngr = greybl = blueli = purple

Please note!

Please note!

Cable colours circuit diagramssw = blackws = whitert = redge = yellowgn = greenvi = violetbr = browngr = greybl = blueli = purple

https://eberspacher-russia.ru

Page 62: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

62

252069009901B

Circuit diagram, control units – ADR

PartslistPage61

Circuitdiagram6

https://eberspacher-russia.ru

Page 63: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

63

Circuitdiagram6Circuit diagram, control unit EasyStart T – ADR(Controlboxwithonediagnosticscable)

252069009709PartslistPage61

https://eberspacher-russia.ru

Page 64: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

64

Circuitdiagram6Circuit diagram, control unit EasyStart T – ADR(Controlboxwithtwodiagnosticscables)

252361009704PartslistPage61

https://eberspacher-russia.ru

Page 65: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

65

Certification

ThehighqualityofEberspächer’sproductsisthekeytooursuccess.Toguaranteethisquality,wehaveorganisedallworkpro-cessesinthecompanyalongthelinesofqualitymanagement(QM).Evenso,westillpursuealargenumberofactivitiesforcon-tinuousimprovementofproductqualityinordertokeeppacewiththesimilarlyconstantlygrowingrequirementsmadebyourcustomers.Allthestepsnecessaryforqualityassurancearestipulatedininternationalstandards.Thisqualityistobeconsideredinatotalsense.Itaffectsproducts,proceduresandcustomer/supplierrela-tions.Officiallyapprovedpublicexpertsassessthesystemandthecorrespondingcertificationcompanyawardsacertificate.

Eberspächerhasalreadyqualifiedforthefollowingstandards:

Quality management in accordance with DIN EN ISO 9001:2000 and ISO/TS 16949:1999

Environmental management system in accordance withDIN EN ISO 14001:1996

Disposal

Disposal of materialsOlddevices,defectcomponentsandpackagingmaterialcanallbeseparatedandsortedintopure-gradefactionssothatallpartscanbedisposedofasrequiredinanenvironment-friendlymannerrecycledwhereapplicable.Electricmotors,controlboxesandsensors(e.g.temperaturesensors)aredeemedtobe“electronicscrap”.

Dismantling the heaterTheheaterisdismantledaccordingtotherepairstagesinthecurrenttroubleshooting/repairinstructions.

PackagingThepackagingoftheheatercanbekeptincaseithastobesentback.

EC Declaration of Conformity

Withregardtothefollowingproducts

Heater type Airtronic / Airtronic M

weherewithconfirmthatitconformswiththeprimesafetyrequirementsstipulatedinthedirectivesoftheEUCouncilforharmonisationofthelegalregulationsofthememberstateswithregardtoelectromagneticcompatibility(89/336/EEC).ThisdeclarationappliestoallheatersproducedaccordingtotheproductiondrawingsAirtronic/AirtronicM–whichareanintegralpartofthisdeclaration.Thefollowingstandards/directiveshavebeenusedtoassesstheproductwithregardtoelectromagneticcompatibility:• EN50081–1Basicforminterferenceemission• EN50082–1Basicformofinterferenceimmunity• 72/245/EEC–Modificationstatus2006/28/EC. Interferencesuppressioninmotorvehicles.

Service7

https://eberspacher-russia.ru

Page 66: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

66

Service7List of key words / A – Z index

AAccidentprevention...............................................................4ADR..........................................................................7,59,69Alwaysobservethefollowingsafetyinstructionsbeforework-ingontheheater.................................................................28AMPreleasetool.................................................................28Assemblydrawing...............................................................29Assignmentofthecircuitdiagrams......................................49

Bbasicadapter......................................................................19

CCancelthecontrolboxlock...........................................16,20cancelthecontrolboxlock..................................................17Certification.........................................................................65Checkcombinationsensor..................................................32Checkfuelsupply................................................................36Checkvalues.......................................................................12Circuitdiagram....................................................................37Circuitdiagram,controlunits...............................................42Controlandsafetydevices.....................................................7Controlintheheatingmode...................................................6Cutawayview........................................................................5

DDescriptionoffunctions.........................................................6Diagnosticunit.....................................................................15Disposal..............................................................................65

EEasyStartR+radioremotecontrol.......................................22EasyStartTtimer.................................................................22ECDeclarationofConformity...............................................65ECtype-approval.................................................................69EDiTHdiagnostictool....................................................17,19EMCdirective......................................................................69EMERGENCYOFF................................................................7Emergencyshutdown............................................................7

FFAME..................................................................................69Faultcode...........................................................................23Faultdescription..................................................................23Forcedshut-down.................................................................7Foreword...............................................................................4

IImportantinformation............................................................4ISOadapter.........................................................................17

LListofabbreviations.............................................................69

MMeasuringthefuelquantity..................................................36Moduletimer.......................................................................20

OOverviewofthepartslistsandcircuitdiagrams....................37

PPartslistcircuitdiagramcontrolunits...................................49Partslistcircuitdiagramcontrolunits–ADR........................61Partslistcircuitdiagrams...............................................38,58Partslistcircuitdiagrams,controlunits................................41

RRepairinstructions.........................................................28,30Representativesabroad.................................................66,67

SService................................................................................65Specialtool..........................................................................28StartingAirtronic...................................................................6StartingAirtronicM................................................................6Switchingoff..........................................................................6Switchingon..........................................................................6

TTableofflamesensorvalues................................................32Tableofoverheatingsensorvalues......................................32Tableofvalues–fuelquantity..............................................36Technichaldata.....................................................8,9,10,11Temperatureselection............................................................6Testingdeviceforthecontroldevice....................................15TP5radioremotecontrol.....................................................21Troubleshooting...................................................................13

VVentilatingmode....................................................................6

WWhattocheckfirst..............................................................13

Keyword Page Keyword Page

https://eberspacher-russia.ru

Page 67: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

67

Service7List of abbreviations

ADREuropeanagreementabouttheinternationaltransportofdan-gerousgoodsontheroad.

EC type-approvalPermitawardedbytheFederalVehicleOfficefortheproduc-tionofaheaterforinstallationinmotorisedvehicles.

EMC directiveElectromagneticcompatibility.

JE-PartnersJ.Eberspächerpartner.

FAME (biodiesel)FAMEfordieselenginesaccordingtoDINEN14214.

https://eberspacher-russia.ru

Page 68: AIRTRONIC / AIRTRONIC M...V = Combustion air Function2 and use 6 Description of functions Switching on When the heater is switched on, the control lamp in the con-trol unit lights

Sub

ject

toc

hang

es

Prin

ted

inG

erm

any

©

J.E

bers

päch

erG

mbH

&C

o.K

G

J.EberspächerGmbH&Co.KG Eberspächerstraße24 D-73730Esslingen Telephone0711939-00 Facsimile0711939-0643

https://eberspacher-russia.ru


Recommended