© 2020 Electric Power Research Institute, Inc. All rights reserved. www.epri.com Software Vendors: J. J. Sanchez-Gasca, Jay Senthil, Jamie Weber, Pouya Zadkhast EPRI: Deepak Ramasubramanian, Anish Gaikwad PEACE®: Pouyan Pourbeik WECC MVS Virtual Meeting August 24 th – 27 th , 2020 Benchmarking of REGC_B + REEC_D models Status update
Transcript
Page 1: Benchmarking of REGC and REEC models · Preliminary model benchmarking of REGC_B + REEC_D beta models has been progressing. Beta models developed in the software. In Test 1 and Test

© 2020 Electric Power Research Institute, Inc. All rights reserved.w w w . e p r i . c o m

Software Vendors: J. J. Sanchez-Gasca, Jay Senthil, Jamie Weber, Pouya Zadkhast

EPRI: Deepak Ramasubramanian, Anish Gaikwad

PEACE®: Pouyan Pourbeik

WECC MVS Virtual MeetingAugust 24th – 27th, 2020

Benchmarking of REGC_B +

REEC_D modelsStatus update

Page 2: Benchmarking of REGC and REEC models · Preliminary model benchmarking of REGC_B + REEC_D beta models has been progressing. Beta models developed in the software. In Test 1 and Test

© 2020 Electric Power Research Institute, Inc. All rights reserved.w w w . e p r i . c o m2

Test Protocol…Test number Description

Test 1

A-a/b

To test the voltage source interface, apply an X=0.005pu fault on

Bus 2 for 8 cycles

X10004-20004 = 0.106pu

B-a/b X10004-20004 = 0.206pu

C-a/b X10004-20004 = 0.406pu

D-a/b X10004-20004 = 0.706pu

Test 2 A-a/b X10004-20004 = 0.706pu, GENMVA = 100.0, H=2.5

▪ Preliminary model benchmarking of REGC_B + REEC_D beta models has been progressing.▪ Beta models developed in the software.▪ In Test 1 and Test 2, a represents use of REGC_A model while b represents use of REGC_B

Test Number Flag Setting DescriptionTest 3 PfFlag=1; VFlag = 0; QFlag=0;

Vcmpflag=1; PFlag=0Step change of 0.1pu in Vref0,

X10004-20004 = 0.106pu, GENMVA = 10000.0, H=5.0

Test 4Ai PfFlag=0; VFlag = 1; QFlag=1; Vcmpflag=0; PFlag=0

Step change of 0.2pu in QextX10004-20004 = 0.106pu, GENMVA =

10000.0, H=5.0

Test 4Aii PfFlag=0; VFlag = 1; QFlag=1; Vcmpflag=0; PFlag=0

Step change of 0.2pu in QextX10004-20004 = 0.706pu, GENMVA =

100.0, H=2.5

Test 4Bi PfFlag=0; VFlag = 1; QFlag=1; Vcmpflag=1; PFlag=0

Step change of 0.2pu in QextX10004-20004 = 0.106pu, GENMVA =

10000.0, H=5.0

Test 4Bii PfFlag=0; VFlag = 1; QFlag=1; Vcmpflag=1; PFlag=0

Step change of 0.2pu in QextX10004-20004 = 0.706pu, GENMVA =

100.0, H=2.5

Test 5i PfFlag=0; VFlag = 1; QFlag=1; Vcmpflag=1; PFlag=0

Step change of 0.2pu in Paux, X10004-20004 = 0.106pu, GENMVA =

10000.0, H=5.0Test 5ii PfFlag=0; VFlag = 1; QFlag=1;

Vcmpflag=1; PFlag=0Step change of 0.2pu in Paux,

X10004-20004 = 0.706pu, GENMVA = 100.0, H=2.5

Page 3: Benchmarking of REGC and REEC models · Preliminary model benchmarking of REGC_B + REEC_D beta models has been progressing. Beta models developed in the software. In Test 1 and Test

© 2020 Electric Power Research Institute, Inc. All rights reserved.w w w . e p r i . c o m3

Summary of results and outcome…

▪ Overall, performance of both REGC_B and REEC_D across all four software platforms is consistent for all tests.

▪ Few points to be noted regarding these tests:

– The values of parameters chosen for the models are not necessarily representative of a realistic set. They were chosen to stress the models

– Due to various timers and voltage thresholds involved, numerical precision of the solvers can play a huge role in the dynamic behavior

– The behavior of the REGC_B model is dependent on the behavior of the network solution solver (which is slightly different in each software)

Page 4: Benchmarking of REGC and REEC models · Preliminary model benchmarking of REGC_B + REEC_D beta models has been progressing. Beta models developed in the software. In Test 1 and Test

© 2020 Electric Power Research Institute, Inc. All rights reserved.w w w . e p r i . c o m4

Results of all tests

Page 5: Benchmarking of REGC and REEC models · Preliminary model benchmarking of REGC_B + REEC_D beta models has been progressing. Beta models developed in the software. In Test 1 and Test

© 2020 Electric Power Research Institute, Inc. All rights reserved.w w w . e p r i . c o m5

Test1Aa

Page 6: Benchmarking of REGC and REEC models · Preliminary model benchmarking of REGC_B + REEC_D beta models has been progressing. Beta models developed in the software. In Test 1 and Test

© 2020 Electric Power Research Institute, Inc. All rights reserved.w w w . e p r i . c o m6

Test1Ab

Page 7: Benchmarking of REGC and REEC models · Preliminary model benchmarking of REGC_B + REEC_D beta models has been progressing. Beta models developed in the software. In Test 1 and Test

© 2020 Electric Power Research Institute, Inc. All rights reserved.w w w . e p r i . c o m7

Test1Ba

Page 8: Benchmarking of REGC and REEC models · Preliminary model benchmarking of REGC_B + REEC_D beta models has been progressing. Beta models developed in the software. In Test 1 and Test

© 2020 Electric Power Research Institute, Inc. All rights reserved.w w w . e p r i . c o m8

Test1Bb

Page 9: Benchmarking of REGC and REEC models · Preliminary model benchmarking of REGC_B + REEC_D beta models has been progressing. Beta models developed in the software. In Test 1 and Test

© 2020 Electric Power Research Institute, Inc. All rights reserved.w w w . e p r i . c o m9

Test1Ca

Page 10: Benchmarking of REGC and REEC models · Preliminary model benchmarking of REGC_B + REEC_D beta models has been progressing. Beta models developed in the software. In Test 1 and Test

© 2020 Electric Power Research Institute, Inc. All rights reserved.w w w . e p r i . c o m10

Test1Cb

Page 11: Benchmarking of REGC and REEC models · Preliminary model benchmarking of REGC_B + REEC_D beta models has been progressing. Beta models developed in the software. In Test 1 and Test

© 2020 Electric Power Research Institute, Inc. All rights reserved.w w w . e p r i . c o m11

Test1Da

Page 12: Benchmarking of REGC and REEC models · Preliminary model benchmarking of REGC_B + REEC_D beta models has been progressing. Beta models developed in the software. In Test 1 and Test

© 2020 Electric Power Research Institute, Inc. All rights reserved.w w w . e p r i . c o m12

Test1Db

*Few minor modifications are still being carried out in PowerWorld’s representation of the model

Page 13: Benchmarking of REGC and REEC models · Preliminary model benchmarking of REGC_B + REEC_D beta models has been progressing. Beta models developed in the software. In Test 1 and Test

© 2020 Electric Power Research Institute, Inc. All rights reserved.w w w . e p r i . c o m13

Test2Aa

Page 14: Benchmarking of REGC and REEC models · Preliminary model benchmarking of REGC_B + REEC_D beta models has been progressing. Beta models developed in the software. In Test 1 and Test

© 2020 Electric Power Research Institute, Inc. All rights reserved.w w w . e p r i . c o m14

Test2Ab

*Few minor modifications are still being carried out in PowerWorld’s representation of the model

Page 15: Benchmarking of REGC and REEC models · Preliminary model benchmarking of REGC_B + REEC_D beta models has been progressing. Beta models developed in the software. In Test 1 and Test

© 2020 Electric Power Research Institute, Inc. All rights reserved.w w w . e p r i . c o m15

Test3

*PowerWorld does not provide an option to introduce step change in Vref0

Page 16: Benchmarking of REGC and REEC models · Preliminary model benchmarking of REGC_B + REEC_D beta models has been progressing. Beta models developed in the software. In Test 1 and Test

© 2020 Electric Power Research Institute, Inc. All rights reserved.w w w . e p r i . c o m16

Test4Ai

Page 17: Benchmarking of REGC and REEC models · Preliminary model benchmarking of REGC_B + REEC_D beta models has been progressing. Beta models developed in the software. In Test 1 and Test

© 2020 Electric Power Research Institute, Inc. All rights reserved.w w w . e p r i . c o m17

Test4Aii

Page 18: Benchmarking of REGC and REEC models · Preliminary model benchmarking of REGC_B + REEC_D beta models has been progressing. Beta models developed in the software. In Test 1 and Test

© 2020 Electric Power Research Institute, Inc. All rights reserved.w w w . e p r i . c o m18

Test4Bi

Page 19: Benchmarking of REGC and REEC models · Preliminary model benchmarking of REGC_B + REEC_D beta models has been progressing. Beta models developed in the software. In Test 1 and Test

© 2020 Electric Power Research Institute, Inc. All rights reserved.w w w . e p r i . c o m19

Test4Bii

Page 20: Benchmarking of REGC and REEC models · Preliminary model benchmarking of REGC_B + REEC_D beta models has been progressing. Beta models developed in the software. In Test 1 and Test

© 2020 Electric Power Research Institute, Inc. All rights reserved.w w w . e p r i . c o m20

Test5i

Page 21: Benchmarking of REGC and REEC models · Preliminary model benchmarking of REGC_B + REEC_D beta models has been progressing. Beta models developed in the software. In Test 1 and Test

© 2020 Electric Power Research Institute, Inc. All rights reserved.w w w . e p r i . c o m21

Test5ii

Page 22: Benchmarking of REGC and REEC models · Preliminary model benchmarking of REGC_B + REEC_D beta models has been progressing. Beta models developed in the software. In Test 1 and Test

© 2020 Electric Power Research Institute, Inc. All rights reserved.w w w . e p r i . c o m22

Together…Shaping the Future of Electricity


Recommended