Page 1: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

Catalog

Page 2: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

2

P-I product line was developed by the Osseointegration pioneer, Professor Per-Ingvar Brånemark, jointly with experienced scientists in world recognized entities to meet modern Implant Dentistry demands.

To further complement the P-I portfolio the company Ospol AB was acquired. Founded in 2002 – Sweden, Ospol AB primarily commercialized its products in Europe, delivering outsanding technologies.

With knowledge and based on scientific evidences the main objective of the P-I brand is to offer professionals and patients competitive solutions represented by:

. Simplification

. High Performance

. Safety and Longevity

The fundamental goal is to restore the quality of life of patients.

P-I brand belongs to Zimmer Holdings, a global orthopedic leader that researches, develops, manufactures and commercializes solutions for reconstructive orthopedics, spine, trauma and surgery devices and, via Zimmer Dental, offers a broad portfolio of dental implants, components, biomaterials and digital dentistry.

Founded in 1927 and incorporated in the United States in 2001, Zimmer is an independent public company present in more than 100 countries worldwide.

Page 3: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

3

Content

Prosthetic Interface - 4

Surfaces - 5

External Hexagon | HEX–S and HEX - 6

Amplified® | AMP - 13

Morse Taper | MT - 20

Kits - 28

Instruments - 32

Accessories - 34

Surgical Sequence - 36

Torques - 38

Implant Packaging - 39

Zimmer, Zimmer Dental, ZFx™, P-I, Ospol, Amplified and www.pibranemark.com are Zimmer Group’s properties.Other trademarks are used for reference purposes only and belong to other companies.

(!) Some products may not be available in your region. Please check availability.

Page 4: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

4

Prosthetic Interface

ProsthesisSinglePartialTotalCementedScrew-retained

SeatingConical Hexagonal Indexation

HEX-S HEX AMP MT

RegionAnteriorPosterior

Platform Switching

Bone Level Installation

Micro Threads

Morse Sealing

Macrogeometry

Cortical BonePreservation

Soft Tissue Maintenance

High Esthetic Demand

Ø 5.1(Ø3.95 Components on Ø4.1 Platform)

Ø 5.1(Ø3.95 Components on Ø4.1 Platform)

(or 0.5 - 1.0 mm below) (or 0.5 - 1.5 mm below)

Parallel Emergence Profile

Parallel Emergence Profile

Parallel Emergence Profile

Parallel Emergence Profile

External Hexagon Morse TaperAmplified®

Page 5: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

5

Surfaces

Surfaces and Risk FactorsThere are several risk factors in Osseointegration widely described in literature. The schedule above only demonstrates suggested use for the P-I Surfaces.

* Lekholm U, Zarb GA

Bone Density* Type IType IIType IIIType IV

Bone Healing Potential (!)

NormalSlightly ChangedHeavily Changed

Advanced TechniqueBone AugmentationGrafts | Biomaterials

Loading Immediate EarlyDelayed

Surface StructureMethodMicro TopographyNano TopographyChemical Composition

Low Roughness Minimally Rough

Micro Blasting + PIIIOxidized + Ca+2

TiO2 + Calcium

+ +++++

TiO2

The Life Time product guarantee is limited to product replacement in case of loss.Please refer to www.pibranemark.com/guarantee for applicable terms and conditions.

(!) As described in the literature | Smart Guide.

Page 6: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

6

External Hexagon | Hybrid Implants

HEX | Functional

HEX-S | Solid

3.3

3.5

3.5

3.75

4.1

4.1

h10

11.5

13

15

Ø Platform

Ø Platform

Ø Implant

102935

102936

102937

102938

102903

102904

102905

102906

102943

102944

102945

102946

102911

102912

102913

102914

102959

102960

102961

102927

102928

102929

4.8

5.1

5.1

3.3

3.5

3.5

3.75

4.1

4.1

4.8

5.1

5.1

h6

7

8.5

10

11.5

13

15

18

3.3 3.33.75 4.0 (!) 3.75 4.0 (!)5.0 5.0Ø Implant

102803

102804

102805

102806

102445

102446

102447

102448

102808

102809

102810

102811

102812

102813

102814

102815

102451

102452

102453

102454

102455

102456

102457

102458

102824

102825

102826

102827

102828

102829

102469

102470

102471

102472

102473

102474

102816

102817

102818

102819

102820

102821

102822

102823

102460

102461

102462

102463

102464

102465

102466

102467

HEX

-S | HEX

Surfaces

(!) Ø4.0 External Hexagon Implants are primarily utilized for rescue (When insertion stability is not reached with Ø3.75).Platform Ø5.1 has the same Hexagon for Platform, allowing use of 4.1 Components (Platform Switching).

Page 7: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

7

35

345

Soft Tissue Healing

Healing Abutment Divergent

Healing Abutment Parallel

Cover Screw

102773102774

101072101073101074

101064

102775 102776

101068 101069 101070

101065

102771102772

101589

101591

101612

Ø Platform

3.5h 5.14.1

Possible use of Ø4.1 Components.

HEX

-S | HEX

Page 8: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

8

Conical AbutmentIndicated for multiple, screw retained prosthesis

Ø Platform

Cylinders

Healing Cap

Conical Abutment - 30º

Conical Abutment - 17º

Conical Abutment - StraightParallel

Analog

Impression Copings

3.5 5.14.1

Non-Engaging (NEng)Titanium | Provisional

CastableCobalt Chromium Molybdenum

Open Tray (OT) | Multiple Closed Tray (CT) | Multiple

Divergent

101142101143101141

101142101143101141

101142101143101141

171247

102385101113

101155

102389102390

101770101771101772

101045

102391102392102708102709

101155

101155

101658

101659101660

171247

102385101113

171247

102385101113

45

h

234

1

2345

Ø5.1 Platform uses 4.1 Components only.(!) Conical Abutment prosthetic Platform is the same in all diameters.(!) Maximum occlusal angulation between two Abutments is 40º

HEX

-S | HEX

Page 9: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

9

h

Abutment Cemented CylinderIndicated for single or multiple, cement retained prosthesis

Ø Platform

Castable Cylinders

Analogs

Impression Copings

Healing Caps

Abutment Cemented Cylinder 4 mm Cone

Abutment Cemented Cylinder 6 mm (L) Cone

3.5 5.14.1

Non–Engaging (NEng)6 mm (L)

4 mm

Engaging (Eng)6 mm (L)

4 mm

6 mm (L)4 mm

Closed Tray (CT) - 6 mm (L)Closed Tray (CT) - 4 mm

6 mm (L)4 mm

123

1234

161418101747

161419101746

161415101745

161417101744

161416101743

101152101153101154

102669102670102671102673

101977

101976

101975

101974

101973

101967 101968 101969

Possible use of Ø4.1 Components. Ø5.1 Platform uses 4.1 Components only.

HEX

-S | HEX

Page 10: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

10

Esthetic AbutmentIndicated for single or multiple, cement retained prosthesis

Ø Platform

Esthetic Abutment - 15º

Esthetic Abutment – Straight

3.5 5.14.1

123

123

101058101059101060

101055101099101057

102710101680102711

102712101677102713

Possible use of Ø4.1 Components. Ø5.1 Platform uses 4.1 Components only.

h

Open Tray (OT) Closed Tray (CT)

Implant Analogs

Implant Impression Copings

101114

101106101109

101957

101952 101955

101687

101682102427

HEX

-S | HEX

Page 11: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

11

Possible use of Ø4.1 Components.

Non-Engaging (NEng) Titanium | Provisional

Castable Cobalt Chromium Molybdenum

Engaging (Eng) Titanium Castable

Cobalt Chromium Molybdenum

Open Tray (OT)Closed Tray (CT)

Implant Analogs

Cylinders over Implant

Implant Impression Copings

101150101151101149

101147101148101146

101114

101106101109

101965 101966 101963

101961 101962 101959

101957

101952 101955

101695101696101693

101691101692101689

101687

101682102427

Cylinders over ImplantIndicated for single or mutiple, cemented or screw retained prosthesis

Ø Platform

3.5 5.14.1

HEX

-S | HEX

Page 12: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

12

CAD / CAM Solution

Overdenture Solutions

Ø Platform

Ball Abutment Ø2.5*

3.5 5.14.1

12345

101978101979101980101981101982

h

HEX

-S | HEX

Ø Platform

Scan Body Conical Abutment (!)

3.5 5.1 4.1

161471 161471161471

(!) P-I Interfaces, Links and Scan Bodies are listed in the libraries of Zimmer® Zfx™ and other systems. Please check availability in your region.Zimmer® Zfx™ supplies Scan Bodies and Matchholders for the P-I product line.

* Ball Abutments, Components and Instruments are universal and not listed in this Catalog. Please check availability in your region. Ø5.1 Platform uses 4.1 Components only.

Page 13: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

13

AMP

3.3

3.5

4.0

4.3

4.8

5.1

h7

8.5

10

11.5

13

15

Ø Platform

Ø Implant

161440

161441

161442

161444

161445

161393

161394

161211

161212

161213

161446

161447

161448

161449

161450

161451

161240

161241

161242

161425

161243

161244

161456

161457

161452

161453

161454

161455

161252

161253

161254

161255

161256

161257

3.3

3.5

4.0

4.3

4.8

5.1

Amplified® | Functional Hybrid Implants

AM

P

(!) Ø4.3 and 5.1 Platform have identical cone and index dimensions allowing interchange of Components.

Surfaces

Page 14: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

14

34.5

1.53

4.5

Soft Tissue Healing

161431161432

161105161042161043

161041 161041

161429161430

161104161027161028

161026

Ø Platform

3.5 5.1 4.3

Healing Abutment Divergent

Healing Abutment Parallel

Cover Screw

h

AM

P

Ø5.1 Platform uses 4.3 Components only.

Page 15: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

15

Conical AbutmentIndicated for multiple and single screw retained prosthesis

Ø Platform

Cylinders

Healing Cap

Conical Abutment - 30º

Conical Abutment - 17º

Conical Abutment - Straight

Analog

Impression Copings

3.5 5.1 4.3

Non-Engaging (NEng)Titanium | Provisional

CastableCobalt Chromium Molybdenum

Engaging (Eng)TitaniumCastable

Cobalt Chromium Molybdenum

Multiple and Single

Non-Engaging (NEng)Open Tray (OT) | Multiple

Closed Tray (CT) | Multiple

Engaging (Eng) Open Tray (OT) | Single

Closed Tray (CT) | Single

Multiple

Multiple

Multiple and Single

101142101143 101141

171248171250171249

101142101143 101141

171248171250171249

101142101143 101141

171248171250171249

171247

102385101113

171245171246

101155

161119

161116161117

161433161434

161361161049161051161362

101155101155

161102161103

171247

102385101113

171245171246

171247

102385101113

171245171246

3

1.53

0.81.5

34.5

h

AM

P

Ø5.1 platform uses 4.3 Components only.(!) Conical Abutment prosthetic Platform is the same in all diameters.(!) Maximum occlusal angulation between two Abutments is 40º

Page 16: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

16

Abutment Cemented CylinderIndicated for single or multiple cement retained prosthesis

Ø Platform

Castable Cylinders

Analogs

Impression Copings

Healing Caps

Abutment Cemented Cylinder 4 mm Cone

Abutment Cemented Cylinder6 mm (L) Cone

Abutment Cemented Cylinder“0” (!)

3.5 5.1 4.3

Non-Engaging (NEng)6 mm (L)

4 mm

Engaging (Eng)6 mm (L)

4 mm

6 mm (L)4 mm

Closed Tray (CT) - 6 mm (L)Closed Tray (CT) - 4 mm

6 mm (L)4 mm

0.81.5

34.5

0.81.5

34.5

0

161418101747

161419101746

161415101745

161417101744

161416101743

161107 161108 161109

161406

161303 161037 161038

161304

161114

161423101977

161424101976

161420101975

161422101974

161421101973

161111 161112

161058 161059

161115

161413161463

161414161464

161410161462

161412161461

161411161460

161401161402161403

161301161032161033161302

161113

Possible use of Ø4.3 and 5.1 Components. Ø5.1 Platform uses 4.3 Components only.

(!) Not compatible with Healing, Impression and Cylinders system.

h

AM

P

Page 17: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

17

Esthetic AbutmentIndicated for single or multiple cement retained prosthesis

Ø Platform

Esthetic Abutment - 15º

Esthetic Abutment - Straight

3.5 5.1 4.3

1.53

4.5

0.81.5

34.5

161046161047161369

161380161381161382161383

161034161035161366

161376161377161378

Possible use of Ø4.3 Components. Ø5.1 Platform uses 4.3 Components only.

h

AM

P

Open Tray (OT)Closed Tray (CT)

Implant Analogs

Implant Impression Copings

161040

161044161120

161055 161025

161029161200

Page 18: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

18

Engaging (Eng) Titanium | Provisional

Cobalt Chromium Molybdenum

Open Tray (OT)Closed Tray (CT)

Implant Analogs

Cylinders over Implant

Implant Impression Copings

161054 161053

161040

161044161120

161061 161060

161055

161039161036

161025

161029161200

Cylinders over ImplantIndicated for single or mutiple, cemented or screw retained prosthesis

Ø Platform

3.5 5.1 4.3

Possible use of Ø4.3 and 5.1 Components. Ø5.1 Platform uses 4.3 Components only.

AM

P

Page 19: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

19

CAD / CAM Solutions

Ø Platform

Ø Platform

Overdenture Solution

Links

Locator® Abutment*

3.5

3.5

5.1

5.1

4.3

4.3

0.81.5

34.5

0.81.5

34.5

161471

161470

161427161281161282161283

161465161466161467161468

161471

161470

161471

161469

161426161277161278161279

h

h

AM

P

(!) P-I Interfaces, Links and Scan Bodies are listed in the libraries of Zimmer® Zfx™ and other systems. Please check availability in your region.Zimmer® Zfx™ supplies Scan Bodies and Matchholders for P-I product line.The Implant Scan Bodies for AMP and MT are recommended for single units and use with intraoral and desk scanners. For a multiple prosthesis please consider P-I Conical Abutment Scan Bodies with universal Platform.

*Locator® Abutment Components and Instruments are universal and not listed in this Catalog. Please check availability in your region. Ø5.1 Platform uses 4.3 Components only.

Scan Body Conical Abutment (!)

Scan Body Implant (!)

Page 20: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

20

MT

3.3

3.5

3.75

4.1

4.8

5.1

h6

7

8.5

10

11.5

13

15

Ø Platform

Ø Implant

171032

171033

171034

171035

171036

171003

171004

171005

171006

171007

171038

171039

171040

171041

171042

171043

171044

171010

171011

171012

171013

171014

171015

171016

171046

171047

171048

171049

171050

171051

171020

171021

171022

171023

171024

171025

3.3

3.5

3.75

4.1

4.8

5.1

Morse Taper | Solid Hybrid Implants

Surfaces

(!) Platform Ø3.5, 4.1 and 5.1 have identical cone and index dimensions allowing interchange of Components.

MT

Page 21: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

21

1.53

4.5

1.53

4.5

Soft Tissue Healing

171200 171201 171202

171191 171192 171193

171104

171203 171204 171205

171194 171195 171196

171104

171197 171198 171199

171188 171189 171190

171104

Ø Platform

3.5 5.14.1

Healing Abutment Divergent

Healing Abutment Parallel

Cover Screw

h

Possible use of Ø3.5, 4.1 and 5.1 Components.

MT

Page 22: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

22

Conical AbutmentIndicated for multiple and single screw retained prosthesis

Ø Platform

Cylinders

Healing Cap

Conical Abutment - 30º

Conical Abutment - 17º

Conical Abutment - Straight

Analog

Impression Copings

3.5 5.14.1

Non-Engaging (NEng) Titanium Castable

Cobalt Chromium Molybdenum

Engaging (Eng) Titanium

CalcinávelCobalt Chromium Molybdenum

Multiple and Single

Non-Engaging (NEng)Open Tray (OT)

Closed Tray (CT)

Engaging (Eng) Open Tray (OT)

Closed Tray (CT)

Multiple

Multiple

Multiple and Single

101142101143101141

171248171250171249

101142101143101141

171248171250171249

101142101143101141

171247

102385101113

171245171246

101155

171129

171127171128

171123171124171125171126

101155101155

171247

102385101113

171245171246

171247

102385101113

171245171246

3

1.53

0.81.5

34.5

h

Ø3.5 and 5.1 Platform uses 4.1 Components only.(!) Conical Abutment prosthetic Platform is the same in all diameters.(!) Maximum occlusal angulation between two Abutments is 40º

171248171250 171249

MT

Page 23: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

23

h

Abutment Cemented CylinderIndicated for single or multiple cement retained prosthesis

Ø Platform

Castable Cylinders

Analogs

Impression Copings

Healing Caps

Abutment Cemented Cylinder 4 mm Cone

Abutment Cemented Cylinder 6 mm (L) Cone

3.5 5.14.1

6 mm (L)4 mm

Closed Tray (CT) - 6 mm (L)Closed Tray (CT) - 4 mm

6 mm (L)4 mm

0.81.5

34.5

0.81.5

34.5

161415101745

161417101744

161416101743

171159 171160 171161 171162

171144 171145 171146 171147

161420101975

161422101974

161421101973

171164 171165 171166 171167

171149 171150 171151 171152

161410161462

161412161461

161411161460

171154 171155 171156 171157

171139 171140 171141 171142

Possible use of Components with Ø3.5, 4.1 and 5.1(!) Not compatible with Healing, Impression and Cylinders system.

Non-Engaging (NEng)6 mm (L)

4 mm

Engaging (Eng)6 mm (L)

4 mm

161418101747

161419101746

161423101977

161424101976

161413161463

161414161464

Abutment Cemented Cylinder“0” (!)

0 171143 171148 171138

MT

Page 24: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

24

Esthetic AbutmentIndicated for single or multiple cement retained prosthesis

Ø Platform

Esthetic Abutment - 15º

Esthetic Abutment - Straight

3.5 5.14.1

1.53

4.5

0.81.5

34.5

171179 171180 171181

171172 171173 171174 171175

171176 171177 171178

171168 171169 171170 171171

h

Possible use of Ø3.5 and 4.1 Components. Ø5.1 Platform uses 3.5 or 4.1 Components.

Open Tray (OT)Closed Tray (CT)

Implant Analog

Implant Impression Copings

171212

171206171209

171212

171206171209

171212

171206171209

MT

Page 25: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

25

(!) A Interface MT é a mesma em todos os diâmetros de Platformas, possibilitando o intercâmbio de quaisquer Componentes sobre os Implantes.

Ø Platform

Cylinders

Analogs

Impression Copings

Healing Caps

Contour Abutment - 17°

Contour Abutment - Straight

3.5 5.14.1

ProvisionalStraight

17º

Castable Straight

17º

Straight 17º

Straight 17º

Straight 17º

1.53

4.5

1.53

4.5

171222171234

171221171233

171220171232

171219171231

171262171265

171117 171118 171119

171108 171109 171110

171226171238

171225171237

171224171236

171223171235

171263171266

171120 171121 171122

171111 171112 171113

171218171230

171217171229

171216171228

171215171227

171261171264

171114 171115 171116

171105 171106 171107

Contour Abutment Indicated for single or multiple cement retained prosthesis

h

Possible use of 3.5, 4.1 and 5.1 Components.Contour Abutment prosthethic Platform is the same as Zimmer® Dental Contour Abutment.

MT

Page 26: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

26

Engaging (Eng) Titanium | Provisional

Cobalt Chromium Molybdenum

Open Tray (OT) Closed Tray (CT)

Implant Analog

Cylinders overImplant

Implants Impression Copings

171184 171185

171212

171206171209

171186 171187

171212

171206171209

171182 171183

171212

171206171209

Cylinders over ImplantIndicated for single or mutiple, cemented or screw retained prosthesis

Ø Platform

3.5 5.14.1h

Possible use of 3.5, 4.1 and 5.1 Components.

MT

Page 27: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

27

MT

CAD / CAM Solutions

Ø Platform

Ø Platform

Overdenture Solution

Links

Locator® Abutment*

3.5

3.5

5.1

5.1

4.1

4.1

0.81.5

34.5

0.81.5

34.5

161471

161470

171134171135171136171137

172223172224172225172226

161471

161470

171134171135171136171137

161471

161469

171134171135171136171137

h

h

Scan Body Conical Abutment (!)

Scan Body Implant (!)

(!) P-I Interfaces, Links and Scan Bodies are listed in the libraries of Zimmer® Zfx™ and other systems. Please check availability in your region.Zimmer® Zfx™ supplies Scan Bodies and Matchholders for the P-I product line.The Implant Scan Bodies for AMP and MT are recommended for single units and use with intraoral and desk scanners. For a multiple prosthesis please consider P-I Conical Abutment Scan Bodies with universal Platform.

*Locator® Abutment Components and Instruments are universal and not listed in this Catalog. Please check availability in your region. Ø5.1 Platform uses 4.1 Components only.

Page 28: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

28

Kits

Kits

Stainless Steel

L 254 mmH 40 mmW 130 mm

L

HW

Polymer181022

181024

Compact181023

181025

Stainless Steel 181014

181012

Code 181014

Advanced All Implants and Interfaces | Surgical + ProstheticStart-upAll Implants and Interfaces Ø4.1 and 4.3 Platform | Surgical + Prosthetic

Page 29: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

Code181022

29

Kits

Kits

Polymer

L 202 mmH 67 mmW 158 mm

L

W

H

Page 30: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

30

Kits

Compact

L 120 mmH 40 mmW 80 mm

L

W

H

Kits

Code181023

Page 31: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

31

Soft Kits

Prosthetic Kit

External Hexagon | HEX*

Amplified® | AMP*

Morse Taper | MT*

All Interfaces and Components

181026

181027

181028

181029

Kits

* Placement of Implant according to selected Interface in Ø4.1 or 4.3 Platform. * Does not include Torque Wrench. * Includes a handpiece and squared finishing 4x4 Implant Insert Driver (Medium). (!) Ball Attachment and Locator® Instruments are universal and not listed in this catalog (Their Universal instrumentation and tooling are not included in the kits). Please check availability in your region.

Page 32: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

32

Instruments

Implant Insertion

Drills

Interface

AMP | MT

HEX

HEX

HEX | AMP | MT

HEX

All

Drivers (With Rings)

Drivers

Adapter Implant Insert Driver (Manual and

Torque Wrench)

Conical

Dense Drills

Guide Pin (Direction and Depth)

Code

131106131104

131110131112

131108131109

Code

141138

141146

141148

141314

141152

141315

141213

141316

141215

141317

131114

131115

131139131140

131141131142

131130

MediumLong

MediumLong

MediumLong

Ø Implant

Initial

3.3

3.75

4.0

4.8

5.0

MediumLong

MediumLong

Ø Platform

All

4.1 | 5.1

3.5

Ø Drill

2.2

2.8

3.4

3.8

4.6

4.8

Ø Drill | Implant

3.3

3.75

4.0

4.8 | 5.0

2.2 | 2.8

2.8 | 3.8

All (except HEX 3.5)

3.5

Instruments

Page 33: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

33

Code

131128

Code

131131

Code

131129

131010

131011

131012

131016

131017

Short

Medium

Long

Short

Medium

Driver Adapter - Square (4x4)*

Hexagonal Driver Ø1.2

Hexagonal Driver Ø1.2

Hexagonal Driver Ø1.2

Conical Abutment Driver Ø2.0

Conical Abutment Driver Ø2.0

Retriever MT

Torque Wrench | Surgical + Prosthetic

Prosthetic Drivers

Abutment Retriever

Use with Implant Insertion Driver Adapter and Square Adapter (4x4)

* Use with Hexagonal, Conical Abutment and Manual (Squared) Drivers.* Optionally supplied with permanent Hexagonal and Conical Abutment Drivers (Single piece). Please check availability in your region.

Instruments

Instruments

Page 34: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

34

MT

3.5 5.14.1 | 4.3

4.5 171193 171196171190

hA

ccessories

Accessories

Spade

Round Burr

Drill Extension

Stainless Steel - Tray

Polymer - Tray

Compact - Tray

Healing Abutment MT (Selection)

Code

141319Ø1.5

Ø1.8 141001

131028

131117

131134

131138

Osstell® SmartPegs are available for all P-I Interfaces. Please check availability in your region. Visit: www.osstell.com

Selection Abutment | MT

Page 35: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

35

Ø Platform

MTAMPHEX

Replacement | Laboratory Screws

3.53.53.5 5.15.15.1 4.14.14.1

Screw – Imp. Coping - Implant - OT

Screw – Imp. Coping - Implant – CT

Screw – Imp. Coping - Conical Abutment – OT

Screw – Imp. Coping - Conical Abutment CT | Engaging (Eng)

Screw – Cylinders (and Abutments)

Screw – Cylinder - over Implant

171207

102499

171239

101683

102499

101688

101107

101156

101121

171207

102499

101737

171260

101120

171239

101683

102499

101737

171260

101120

101688

101107

101156

101737

101120

101121

171207

102499

101737

171239

101683

102499

101737

101688

101683

102499

101737

101688

Accessories

Page 36: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

36

Surgical Sequence

Caution: Instruments necessary for surgical procedures, performed by qualified and trained professional, must be maintained in ideal mechanical, clean and

sterile conditions.

Internal Grip Drivers must be completely attached to Implants during all surgical installation. Movements to correct

the direction of Implant insertion should not be applied as the surgical site was determined by drill direction. Torques

in excess of the maximum recommended torque (50Ncm) and improperly attached drivers may cause undesired lock

of Drivers inside Implants.

In these possible cases a slight “counter-torque” should be applied to remove the driver.

Removal of Drivers from Implants must be done vertically.

Read Instruction For Use before installing products.

15

18

13

11.5

10

8.5

76

~ 1 mm

During all surgical preparation, coordinated in- and –out movement of drills should be executed

Irrigation must be constant and directed to the insertion margin of drills in the surgical site

Only use the Torque Wrench when at least 3/4 of the Implant is inserted in surgical site

When the Torque Wrench is used by the torque handle the maximum torque should not exceed 50 Ncm

50 Ncm Installation of Hybrid Implants should not exceed 50 Ncm in all clinical cases

Surgical Sequence

Drill Marks

Page 37: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

37

= Soft = Normal = DenseS N D

Surgical Sequence

Ø 2.2 (!) 3.8Drill 4.83.42.8 4.6

r.p.m. 600 - 1,200

S N-D

S

S

S

S-N-D

* Optional

3.3

3.75

4.0

4.8

5.0

N-D

N-D

N-D

Implant

(!) Use of Round Burr and Spade Drill are optional.

Important: During all surgical preparation, the use of Dense Drills should be considered regardless of Implant type

and bone density with the objective of not exceeding 50Ncm of torque. Dense cortical bone removal with Dense

Drills must be always performed in low rotation (15 – 50 r.p.m | Maximum). Dense Drills can be also used to gradually

prepare surgical sites (i.e. widening of the cortical region and post extraction regions).

Hybrid Implants

Surgical Sequence

15

18

13

11.5

10

8.5

76

Page 38: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

38

Recommended Torques (Ncm) and Drivers

Hybrids Implants ≤ 50 ≤ 50 ≤ 50 Internal Grip

Cover Screw Manual 1.2Manual Manual

Healing Abutment

Manual 1.2Manual Manual

HEX AMP MT

Driver

Straight Conical Abutment

25 35 2.025 25

Angled Conical Abutment

25 1.225 25

Abutment Cemented Cylinder

25 35 1.225 25

3.5 5.14.13.5 5.14.33.5 5.14.1

Prosthetic Cylinder(Conical Abutment)

Impression Coping

15

Manual

1.2

1.2

15 15

Manual Manual

Contour Abutment 1.225

Cylinder over Implant

25 35 1.225 25

Link 1.225 25

Scan Body 1.2Manual Manual

Esthetic Abutment 25 35 1.225 25

(!) Caution with cementation procedures must be adopted. A x-ray verification should be used to evaluate and confirm the complete seating of the Components into the Implants Platform (Engaging).All P-I prosthetic Components include Screws.

Ball Abutment 35 1.2

Locator®

Abutment1.235 35

Torques

Page 39: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

39

Implant Packaging

• TitaniumCapsule|Preservesphysical-chemicalSurfaceproperties

• Easyidentification|ColorCodedPlatform

• Datamatrixsystemcontainingkeyproductinformation

• 3traceabilitytags

• Preservationofsterilization

Platform Color

Coding

Dimensions

Product Description

Surface

Item Number

Lot

Datamatrix

(Key Product Information )

Expiry Date

Manufacturing Date

Packaging

Page 40: Catalog - Zimmer Biomet · 4 Prosthetic Interface Prosthesis Single Partial Total Cemented Screw-retained Seating Conical Hexagonal Indexation HEX-S HEX AMP MT Region Anterior Posterior

40

Cata

log-

001-

ENG

-201

5-02

-13

www.pibranemark.com


Recommended