+ All Categories
Home > Documents > Catalogo ADB

Catalogo ADB

Date post: 19-Oct-2015
Category:
Upload: tioino
View: 373 times
Download: 0 times
Share this document with a friend

of 92

Transcript
  • 1Lighting Technologies

    Summary

    Manual Desks SWING 6 / 12 channels 2BOLERO 12 / 24 channels 4

    Memory Desks TANGO 24 / 48 channels 5CANTOR 48 / 96 channels 6MENTOR 120 / 240 / 360 / 512 channels 8PHOENIX/XT 360 - 6144 channels 10Remote Control Wi-Fi / HF / Ethernet 14

    Networks Ethernet/ArNet/ADN 16S2MS Stage & Studio Management System 20

    Dimmer Packs/Racks MICROPACK 15 6 x 2.3 kW 22MICRORACK 25 12 x 2.3 kW 22MEMOPACK 15 XT 6 x 3 kW or 3 x 5 kW 24MEMOPACK 30 12 x 3 kW or 6 x 5 kW 24MEMORACK 15 6 x 3 kW or 3 x 5 kW 26MEMORACK 30 12 x 3 kW or 6 x 5 kW or 3 x 12 kW 26

    Dimmer Cabinets EURORACK 50 24 x 2.3 kW Wallrack 28EURORACK 60 24 x 3 kW or 12 x 5 kW Wallrack 30MEMORACK 180 72 x 3 kW or 36 x 5 kW or 96 x 2.3 kW 32EURODIM 3 225 kW with crate protection 34EURODIM 3 270 kW without crate protection 36

    Theatre Spotlights EUROSPOT 300 / 500 W 40"A" Range 300 / 500 / 650 W 42WARP 800 W Cool Beam Zoom Profile 44WARP 800 W Fully automated Zoom Profile 44EUROPE 1000 / 1200 W 46EUROPE 2000 W 50NIETHAMMER 1200 / 2000 / 2500 W Profiles 54NIETHAMMER 1200 / 2500 W HMI & Halogen Followspots 58

    Batten SVOBODA 9 x 250 W (24 V) 62

    Television Spotlights Studio 1000 / 2000 / 5000 W 64Compact 2000 / 5000 W 64MINOU 2 / 5 5000 W + 2000 W Metal-Halide HQI 66

    Softlights RAH / RAP 2502/5001 2500 / 5000 W 68

    Fill Lights LF 1000 - HF 1000 625 / 1000 / 1250 W 70

    Cyclights ACP / ACV Series 625 / 1000 / 1250 W 72

    Cool Lights SOFTLUX 110 / 220 / 330 / 440 W 74

    Accessories Stands 76Lamps 78Spotlight and promotional Accessories 80

    Rigging Systems Pantographs 84Hoists + Telescopes 86

    Projects Project Management Capabilities 87

    Look-up table Product reference - ADB code number - Product family 89

    Edition 2005/05

    All equipment listed in this catalogue complies with allapplicable European Directives and carries a CE mark.

  • 2Lighting Technologies

    Manual Control Desks

    SWING 6

    6 channel manual desk with DMX512/1990 output on XLR5-Fconnector

    Power Supply :

    VDE approved 9 VDC power supply unit, input 230 V+/- 10% - 50/60 Hz

    Supplied with : 1 external power supply unit, with 1.5 m cable 1 instruction manual

    Dimensions (mm) : 175 x 140 x 48Weight (kg) : 1.2

    SWING 12

    2 preset, 12 channel manual desk with DMX512/1990 outputon XLR5-F connector, with manual crossfade and generalmaster

    Power Supply :

    VDE approved 9 VDC power supply unit, input 230 V +/-10% - 50/60 Hz

    Supplied with : 1 external power supply unit, with 1.5 m cable 1 instruction manual

    Dimensions (mm) : 280 x 247 x 48Weight (kg) : 2.2

  • 3ReferenceDescription

    Lighting Technologies

    SWING 6SWING 12

    SWING 6 + Power Supply SWING 6

    SWING 12 + Power Supply SWING 12

    Accessory

    XLR5-M plug for DMX512/1990 data cable XLR5MX

    Spare Parts

    External power supply unit, with 1.5 m cable ALIM/SWING

  • 4Lighting Technologies

    Manual and MemoryControl Desks

    TANGO Memory Control Desk24 or 48 channels24 or 48 submasterswith DMX512/1990 Output

    Memory control desk configurable as 24 channels / 2 presets or48 channels / 1 preset (TANGO 48); or 12 channels / 2 presetsor 24 channels / 1 preset (TANGO 24) with patch up to 96dimmers, 999 memories, 24 or 48 special effects with flash,128 K memocard library storage (card not supplied).Galvanic isolation on DMX output.Power supply 230 V 10%, 50 / 60 HzSupplied with : 1 power supply cable (2 m)

    1 XLR5-M plug for data cable 1 instruction manual

    with ANALOGUE and DMX512/1990 Outputs

    Equipped with the analogue output kit (0/+10 V or 370 A).Galvanic isolation on DMX output.Power supply 230 V 10%, 50 / 60 HzSupplied with : 1 power supply cable (2 m)

    1 XLR5-M plug for data cable 1 DB25-P plug + cover

    for analogue data cable 1 instruction manual

    TANGO 24 620 x 315 x 118 7

    TANGO 48 815 x 315 x 118 9

    BOLERO 12 500 x 315 x 118 6

    BOLERO 24 730 x 315 x 118 8

    Dimensions (mm) Weight (kg)

    Dimensions (mm) Weight (kg)

    BOLERO Manual Control Desk12 or 24 channelswith DMX512/1990 Output

    2 presets of 12 or 24 channels with manual or timed diplesscrossfade, 12 or 24 special effects with flash.Galvanic isolation on DMX output.Power supply 230 V 10%, 50 / 60 HzSupplied with : 1 power supply cable (2 m)

    1 XLR5-M plug for data cable 1 instruction manual

    with ANALOGUE and DMX512/1990 Outputs

    Equipped with the analogue output kit (0/+10 V or 370 A).Galvanic isolation on DMX output.Power supply 230 V 10%, 50 / 60 HzSupplied with : 1 power supply cable (2 m)

    1 XLR5-M plug for data cable 1 DB25-P plug + cover

    for analogue data cable 1 instruction manual

  • 5ReferenceDescription

    Lighting Technologies

    BOLEROTANGO

    BOLEROBOLERO 12 with DMX512/1990 output BOLERO/12/DMXBOLERO 12 with analogue and DMX512/1990 outputs BOLERO/12/ANABOLERO 24 with DMX512/1990 output BOLERO/24/DMXBOLERO 24 with analogue and DMX512/1990 outputs BOLERO/24/ANA

    Option

    24 channel analogue output kit (non installed) CARTE/ANA/24370 A or 0/+10 V (for BOLERO 12 or BOLERO 24)

    Accessories

    Dust cover for BOLERO 12 HOUSSE/BOLERO 12Dust cover for BOLERO 24 HOUSSE/BOLERO 24Flight case for BOLERO 12 FLY 12/24Flight case for BOLERO 24 FLY 24/48

    TANGOTANGO 24 with DMX512/1990 output TANGO/24/DMXTANGO 24 with analogue and DMX512/1990 outputs TANGO/24/ANATANGO 48 with DMX512/1990 output TANGO/48/DMXTANGO 48 with analogue and DMX512/1990 outputs TANGO/48/ANA

    Options

    24 channel analogue output kit (non installed) 370 A or 0/+10 V for TANGO 24 CARTE/ANA/2448 channel analogue output kit (non installed) 370 A or 0/+10 V for TANGO 48 CARTE/ANA/48

    Accessories

    128 K long life memocard MEMO/CARD/128KDust cover for TANGO 24 HOUSSE/TANGO 24Dust cover for TANGO 48 HOUSSE/TANGO 48Flight case for TANGO 24 FLY 12/24Flight case for TANGO 48 FLY 24/48

  • 6Lighting Technologies

    Memory Control Desks

    CANTOR 48

    48 Channel Memory Control Desk with DMX512/1990 Output

    Memory control desk configurable as 48 channels / 1 preset or24 channels / 2 presets with patch up to 512 dimmers, 200memories, 20 banks of 12 submasters, 9 chasers, 9 specialeffects, 128 K memocard library storage (card not supplied).Galvanic isolation on DMX512 output, MIDI IN-OUT-THRU.Power supply 230 V 10%, 50 / 60 Hz

    Supplied with : 1 power supply cable (2 m) 1 XLR5-M plug for data cable 1 instruction manual

    Optional colour monitor

    with analogue and DMX512/1990 Outputs

    Equipped with the analogue output kit 370 A or 0 / +10V (onSOCAPEX 337 F) for up to 48 dimmers.Power supply 230 V 10%, 50 / 60 Hz

    Supplied with : 1 power supply cable (2 m) 1 XLR5-M plug for data cable 2 Socapex M plugs for analogue data cables 1 instruction manual

    Optional colour monitor

    Notes: If the output mode (current or voltage) is not specified in the

    order, the switch will be in the 0 / +10 V position. To control more than 48 analogue dimmers (maximum

    512), one should use the DMX512 output and adddemultiplexers.

    CANTOR 96

    96 Channel Memory Control Desk with DMX512/1990 Output

    Memory control desk configurable as 24 channels / 2 presets 48 channels / 1 preset 96 channels / 1 preset (2 pages)with patch up to 512 dimmers, 200 memories, 20 banks of12 submasters, 9 chasers, 9 special effects, 128 K memocardlibrary storage (card not supplied).Galvanic isolation on DMX512 output, MIDI IN-OUT-THRU.Power supply 230 V 10%, 50 / 60 Hz

    Supplied with : 1 power supply cable (2 m) 1 XLR5-M plug for data cable 1 instruction manual

    Optional colour monitor

    Note: To control more than 48 analogue dimmers (maximum

    512), one should use the DMX512 output and adddemultiplexers.

    Dimensions (mm) Weight (kg)

    CANTOR 48/96 610 x 685 x 113 11.8

    Colour monitor 356 x 380 x 348 11.3

  • 7ReferenceDescription

    Lighting Technologies

    CANTOR

    CANTOR 48 with DMX512/1990 output CANTOR 48/DMX

    CANTOR 48 with analogue and DMX512/1990 outputs CANTOR 48/ANA

    CANTOR 96 with DMX512/1990 output CANTOR 96/DMX

    Common Accessories

    128 K long life memocard MEMO/CARD/128KDesk lamp WORKLIGHTControl panel for external lines PUP/EXT/LINSet of 2 wooden side panels WOOD/CANTORDust cover HOUSSE/CANTORKit Monitor, RS232, colour, with cable including RS232/VGA converter KIT/MONC/CFlight case for CANTOR FLY/CANTOR

    Accessory for CANTOR 48 only

    Analogue output kit (non installed) 370 A or 0/+10 V PIL48/CANTORfor maximum 48 dimmers, SOCAPEX 337 F outputs

    Extension Kits (non installed)

    Kit 2 for upgrade from CANTOR (old version) to CANTOR 96/DMX KIT 2 / CKit 3 for upgrade from CANTOR 48/DMX to CANTOR 96/DMX KIT 3 / C

  • 8Lighting Technologies

    Memory Control Desks

    MENTOR

    High performance lighting control desk for 120, 240, 360 or512 channels, based on an elaborated version of the wellproven ISIS software, featuring Ethernet capability, motioncontrol, customised user profiles, optional Wi-Fi remote controland manual desk with up to 120 faders. Very compact,lightweight, all-in-one presentation.

    Major Features

    120 channels (instruments) for controlling luminaires, colourchangers and moving lights, expandable to 240, 360, 512channels (instruments)

    1024 DMX addresses OUT (2 universes) with proportionalpatch

    Up to 96 submasters with direct access Manual table with up to 120 faders for direct access Customised user profiles Definable access keys High-grade wheel Keypad for channel/memory selection On-board display for channel & memory selection Theatre/ TV playback with on-board display Grand Master fader Touch screen for easy and direct access to all main functions

    and display of Output, Working field, Patch, Unfold,Instruments, etc...

    Powerful motion control Ethernet networking capability 100 Mb Ethernet for synchronising / tracking DMX through Ethernet Optional Wi-Fi remote control via Pocket PC Audio, MIDI already installed High capacity hard disk for storage Compatible with removable USB flash memory device All in one, portable hardware Optional flight bag

    Technical Characteristics

    Power supply: 230 V +/- 15% - 50 Hz Dimensions (mm): 780 x 475 x 130 Weight (kg): 9

    MENTOR EXTENSION

    24 faders with buttons 6 macro buttons 24 flash buttons Dimensions :

    380 x 475 x 130 mm Weight : 4.7 kg Up to 4 wings

  • 9ReferenceDescription

    Lighting Technologies

    MENTOR

    MENTOR - 120 channels - 1024 DMX addresses - 1 SVGA output MENTOR/120MENTOR - 240 channels - 1024 DMX addresses - 1 SVGA output MENTOR/240MENTOR - 360 channels - 1024 DMX addresses - 1 SVGA output MENTOR/360MENTOR - 512 channels - 1024 DMX addresses - 1 SVGA output MENTOR/512

    Supplied with: Alphanumerical keyboard Supply cable Dust cover Instruction manual

    Options

    24-Submaster EXTENSION for MENTOR SUB24/EXT/M 120 (or 360 512) -Channel upgrade (retrofit) 120CH/UP/M Wi-Fi Remote Control System (Pocket PC +1 Access Point + Software) WIFI/FULL/M Additional Wireless Access Point WIFI/REC/M Wi-Fi Software for Pocket PC WIFI/SOFT/M

    Accessories

    SVGA 15" LCD/TFT monitor LCD/P Wireless Trackball TB/M Desk lamp WORKLITE/M MIDI cable C.MIDI/M External USB CD-RW CDRW/M Removable USB flash memory device FLASHMEM Flight case for MENTOR FLY/M Flight case for 15" LCD/TFT monitor FLY/LCD/P Flight case for MENTOR EXTENSION FLY/SUB24/M Flight bag for MENTOR BAG/M Video Node with power cable (see p. 16) VIDEONODE

    A major Innovation ! Four Desks in one....

  • 10Lighting Technologies

    Lighting Control Systems

    PHOENIX 2/XT

    High performance lighting control system intended for small to medium size stages, TV studios, touring, ... and as a designer'sdesk or a backup unit for larger PHOENIX systems.

    ISIS Software Platform

    PHOENIX 5/XT

    High performance lighting control system intended for medium to large size stages, TV studios, touring, ... and as a backup unitfor PHOENIX 10/XT.

    PHOENIX 10/XT

    The top end lighting control system intended for the most discerning users in major venues, meeting both TV and Theatre requirements.

    PHOENIX XT belongs to the second generation of the PHOENIX lighting control systems introduced in 1999 andfeatures a redesigned and much enhanced software platform

  • 11

    ReferenceDescription

    Lighting Technologies

    PHOENIX/XTGeneral Architecture3 Levels of Control Facilities with the same Software

    PHOENIX 5/XT

    Control Desk connected to the EPU and providing: 96 submasters over 4 pages of 24 faders for creating and running effects, chasers, timed playbacks, groups, memories, moving

    lights and more. 1 keypad for channel, memory, colour, group,... selection. High grade wheel for intensity, times, colour, submasters, etc. Two theatre/TV playbacks and a second virtual playback for crossfading or piling memories, manually or automatically, for

    holding, reversing or controlling the speed of a running crossfade, for jumping to next or previous memories, for browsing forwardand backward the sequence without any influence on the stage.

    One trackball and three digital wheels for motion control. On-board display for visualising stage and preset contents. Extended set of keys for high level operating efficiency. Interfaces for remote control, Ethernet, Audio, HF Remote, MIDI...

    PHOENIX 2/XT

    Control Desk connected to the EPU and providing: 96 submasters over 6 pages of 16 faders for creating and running effects, chasers, timed playbacks, groups, memories, moving

    lights and more. 1 keypad for channel, memory, colour, group,... selection. One theatre/TV playback and a second virtual playback for crossfading or piling memories, manually or automatically, for holding,

    reversing or controlling the speed of a running crossfade, for jumping to next or previous memories, for browsing forward andbackward the sequence without any influence on the stage.

    Easy to use digital belt with integrated bargraph for intensity, motion or time setting. Motion control trackball. Standard set of keys for optimum operating efficiency. Interfaces for remote control, Ethernet, Audio, HF Remote, MIDI...

    PHOENIX 10/XT

    Control Desk connected to the EPU and providing: 96 submasters over 4 pages of 24 faders for running effects, chasers, timed playbacks, groups, memories, moving lights and

    more ! 1 keypad for channel, colour, group, selection and 1 dedicated keypad for memory selection and editing. High grade wheel for intensity, times, colour, submasters, etc... Two theatre / TV playbacks for crossfading or piling memories, manually or automatically, for holding, reversing or controlling

    the speed of a running crossfade, for jumping to next or previous memories, for browsing forward and backward the sequencewithout any influence on the stage.

    Two digital endless belts with integrated bargraph for speed alteration of a running crossfade. One trackball and 4 digital wheels with associated displays for motion control. On-board touch sensitive LCD display (120 x 90 mm) for an easy and direct access to predefined motion control libraries,

    reducing dramatically the time needed to programme moving lights. On-board display for channel and memory selections & for intensity setting. On-board displays for visualising the Stage and Preset contents. Set of keys allowing direct access to high-level managing functions like Save, Load, Print, Synchro, Diagnostic,... Comprehensive set of keys for maximum operating efficiency. Interfaces for remote control, Ethernet, Audio, HF Remote, MIDI...

    Technical CharacteristicsPower Supply : 85 to 264 V - 10 W - 47/440 HzDimensions (mm): 727 x 525 x 128Weight (kg) : 12.3

    Technical CharacteristicsPower Supply : 85 to 264 V - 10 W - 47/440 HzDimensions (mm): 980 x 525 x 128Weight (kg) : 16.9

    Technical CharacteristicsPower Supply : 85 to 264 V - 10 W - 47/440 HzDimensions (mm): 1200 x 525 x 128Weight (kg) : 22

  • 12Lighting Technologies

    PHOENIX/XT

    PHOENIX/XT Main operating Features 512 channels (instruments) for controlling luminaires, colour

    changers and moving lights, expandable in blocks of 512channels (instruments) up to 12 blocks or 6144 channels(instruments).

    8192 DMX addresses OUT (16 universes) with proportionalpatch available through ADB Ethernet nodes.

    2048 DMX addresses IN (4 universes) with proportional patchfor injecting / merging values for allocation to luminaires,colour changers and moving lights.

    Unrestricted allocation of luminaires, colour changers andmoving lights to channels (instruments) and DMX outputs(a 20 parameter moving light requires 1 channel only but 20DMX addresses).

    Each channel (parameter) can be defined as HTP-FTP-LTP. 9999 lighting memories integrating values and times for

    luminaires, colour changers and moving lights. Possibility to allocate to any luminaire, or colour changer, or

    moving light parameter specific times for building complexcrossfades. All channels / parameters can run different waitand fade times simultaneously.

    Possibility to allocate to any memory an automatic orindividual "move in black" with a look ahead option.

    Possibility to load, record and copy specific parts of a lightingstate, of a moving light library or of an instrument.

    Advanced Unfold function for moving lights and colourchangers (Unfold -> Automatic function to link the parametersof a moving light to faders).

    Powerful Learn function. Intelligent Link function to create events for the playback. 16 pre-programmed editable dimmer curves. 999 groups. 99 chasers of 99 steps for luminaires, colour changers and

    moving lights. 99 chasers with individual step times (Cue-list chasers). Library of 20 pre-programmed effect patterns for building

    up to 99 special effects. Advanced Effect Engine for moving lights, colour changers

    and conventional luminaires with more than 30 pre-programmed patterns.

    99 banks of submasters. 999 libraries for colour changers and moving lights. Instrument library with more than 300 different fixtures;

    possibility to create from scratch new device definitions oredit existing definitions.

    Open screen lay-out to fit any requirement. Direct access with pop-up menus to lists of memories,

    groups, chasers, libraries, macros. Selective loading and downloading (network) specific parts

    of data from different existing shows, e.g. from networkeddesks.

    Multi-merge allows multi-desk programming. Data storage on hard disk and archiving on 3.5" floppy disks. ASCII text compatible Import / Export function. 999 Macros for direct use or linked to the sequence, to keys,

    external lines or MIDI events. State-of-the-art Ethernet functions allow full tracking

    back-up, multi-merge of data, DMX through Ethernet, remotemonitoring, file sharing, etc...

    Supports MIDI, MIDI Time Code. Date and Time stamp on any piece of data. Software and on-line Help with hypertext links in several

    languages.

    Based on an industrial PC for the ultimate in quality, reliabilityand world-wide service, with a high speed CPU.

    High capacity hard disk for storage + 3.5" floppy disk drivefor archiving.

    High speed CD-ROM reader for software updates. Compatible with removable USB flash memory device. LINUX operating system providing multi-user and

    pre-emptive multitasking capabilities. Very short boot-up time.

    Standard Ethernet functions Synchronizing / tracking. Up to 10 desk subnets on a network, up to 10 masters on a

    network, up to 10 slaves on a network, unlimited amount ofdesks on a network.

    ArtNet compatible. MSD / Wysiwyg / Sandnet compatible. File server with or without password protection. On/off-line editing. Remote monitors. Multi-user / Multi-merge. ADB nodes NETPORT, NETPORT/ XT, VIDEO Node. ArtNet Nodes. Point-to-point and broadcast. And many other Ethernet functions.

    Back-upA second EPU provides an economical solution for a back-upsystem (PHOENIX/RB/XT). It can be operated via the alphanumerickeyboard, the mouse or any PHOENIX/XT control desk.

    Technical Characteristics (tower version)Power Supply : 90 to 127 V / 200 to 240 V (switchable)

    60 W - 50 / 60 Hz - 15 C ... 35 CDimensions (mm) : 205 x 390 x 505Weight (kg) : 15.3

    Technical Characteristics (19" version)Power Supply : 100 to 120 V / 200 to 240 V (switchable)

    50 / 60 HzDimensions (mm) : 19" x 4U x 518Weight (kg) : 18.1

    New Generation with advanced Ethernet Functions

    External Processing Unit

    (tower version) (19" version)

  • 13

    ReferenceDescription

    Lighting Technologies

    PHOENIX /XT

    PHOENIX/XT Lighting Control System PHOENIX 2/XTBasic configuration consisting of : PHOENIX 5/XT

    PHOENIX 10/XT 1 control desk 1 External Processing Unit (tower) with keyboard + mouse & CD-ROM reader 1 printer output, 1 mouse input, USB input 1 SVGA output LINUX operating system and ISIS software for 512 channels (instruments) 2 physical DMX outputs / 8192 DMX addresses OUT (16 universes) 1 physical DMX input / 2048 DMX addresses IN (4 universes) Ethernet RJ45, IR and HF inputs, Audio, MIDI, external lines, EIA/RS-232 ports Supply and interconnection cables 1 dust cover + instruction manual

    PHOENIX RB/XT Back-up System PHOENIX/RB/XT Hardware configuration same as PHOENIX/XT, however without control desk, IR input, Audio, MIDI, and external lines Software configuration (channels, DMX universes) same as main desk Hardware options must be ordered as for main desk

    Options

    Additional block of 512 channels (instruments) up to 12 blocks or 6144 channels(installed on both PHOENIX/XT and PHOENIX/RB/XT when ordered together) 512CH/P

    4 physical DMX outputs 4DMX/OUT/P 2 SVGA outputs 2SVGA/P 4 SVGA outputs 4SVGA/P Channel / DMX upgrade (retrofit) service charge PHOENIX/UP/SC Software upgrade from PHOENIX to PHOENIX/XT - Main desk P/PXT/UP/1 Software upgrade from PHOENIX to PHOENIX/XT - Second desk or back-up P/PXT/UP/2 External Processing Unit in 19" rack (4U) instead of tower EPU/RACK/P Wi-Fi remote control system (Pocket PC + 1 Access Point + software) WIFI/FULL/M Additional Wireless Access Point WIFI/REC/M Wi-Fi software for Pocket PC WIFI/SOFT/M

    Accessories

    SVGA 17" monitor MON17/P SVGA 15" LCD TFT monitor LCD/P Flight case for PHOENIX 2/XT FLY/P2/P Flight case for PHOENIX 5/XT FLY/P5/P Flight case for PHOENIX 10/XT FLY/P10/P Flight case for Processing Unit FLY/EPU/P Flight case for 15" LCD TFT monitor FLY/LCD/P Wireless trackball TB/M External worklight + dimmer + power supply WORKLITE/P PHOENIX connector kit PLUGKIT/P SVGA video extension cable (4.5 m) VGA/EXT/P Ethernet synchro cable (6 m) C.SYNC/NET External USB CD-RW CDRW/M Removable USB flash memory device FLASHMEM Video Node with power cable (see p. 16) VIDEONODE

  • 14Lighting Technologies

    Remote Control

    for PHOENIX/XT and MENTOR

    Wi-Fi Wireless Remote Control

    ADB Wi-Fi softwareThe ADB Wi-Fi software introduces wireless Ethernet remotecontrol to all PHOENIX/XT and MENTOR desks running ISIS

    v2.10 and later. The software runs on a Pocket PC (MicrosoftWindows Mobile 2003).Functions include channel and memory management, macroexecution, direct access to dimmers and more!

    Simplest configurationThe simplest Wi-Fi configuration requires one Wireless AccessPoint wired to a MENTOR or a PHOENIX/XT lighting console, anda Pocket PC running ADB's Wi-Fi software.

    Network configurationMore elaborate installations will combine, over the venue'sEthernet-for-lighting network, several lighting consoles, severalWireless Access Points, and several Pocket PC's.For an introduction to the user benefits and capabilities ofnetworking over Ethernet, please refer to page 18.

    WarningThis equipment operates in the 2400-2483.5 MHz frequencyband. Users must check whether its use is allowed in theircountry.

    HF Wireless Remote Control

    Wireless Remote ControllerThe wireless remote controller is a sturdy multi-purpose tool, withall the flexibility and user benefits of a wireless system. Functionsinclude playback of channels, groups and memories, starting ofmacros, and direct access to dimmers.

    Simple configurationAn HF System includes a very compact handheld transmitter,and a receiver which is connected to the EIA/RS-232 serial portof the lighting desk.

    ISIS Light Tablet - Advanced GraphicalRemote Control

    The ISIS Light Tablet is a software providing on a Tablet PC ora laptop, a portable, user configurable, virtual console which canremotely activate all the functions of any ADB PHOENIX/XT orMENTOR lighting control system running on ISIS software,V 2.10 and following. Communication is via the Ethernet cable orwireless via Wi-Fi.

    The screen can accommodate the complete front panel of theselected console, or be configured by the user to suit specificrequirements, for ex. any of the ISIS screens in addition to somespecific keys.

    +

  • 15

    ReferenceDescription

    Lighting Technologies

    Remote Control

    Wi-Fi Wireless Remote Control Wi-Fi remote control system (Pocket PC + 1 Access Point + software) WIFI/FULL/M Additional Wireless Access Point WIFI/REC/M Wi-Fi software for Pocket PC WIFI/SOFT/M

    HF Wireless Remote Control HF remote control system (handheld transmitter + active receiver + 19" converter) HF/FULL

    Advanced Graphical Remote Control ISIS Light Tablet Software ISIS/REMOTE

    NEW: ISIS Advanced Graphical Remote Control

  • 16Lighting Technologies

    NETWORKSEthernet and Advanced Dimmer Network (ADN)

    Ethernet / ArtNetADB has adopted the 100 Mbit/s Fast Ethernet networkbased on the widely accepted TCP/IP standard and onArtNet, a protocol designed to allow the distribution of 256DMX512 Universes (over 32,000 channels) organised as 16Sub-Nets of 16 Universes each.ArtNet is in the public domain thus allowing the users tointerconnect nodes and programmes from any manufacturerwho has adopted it. Ethernet data transmission is via a 10BaseTor a 100BaseTX cable generally known as STP/CAT5.

    Video NodeThe Video Node is a portable unit which receives ISIS screensfrom any ISIS device on the ADB Network (ArtNet) or by USBfrom an ISIS console. It is also possible to have a wirelessconnection by the way of a Wi-Fi CF card (option).Video Node has 2 physical SVGA outputs; each output canproduce any ISIS screen.

    NETPORTSimple, low cost Ethernet/ArtNet node (9.5" x 1U) for theconversion of Ethernet into 2 independent DMX512 outputs.NETPORT connects to a 10BaseT network via a RJ45 connector.Supplied with external power supply.

    Ethernet SwitchIntelligent, Fast Ethernet switching hub (19" x 1U) with 10/100Mbit/s auto-sensing capability. Ideal for eliminating traffic jamproblems and network errors, for interconnecting networks ofdifferent speeds and for doubling the network bandwidth in afull-duplex mode. Available with 16 or 24 RJ45 ports andinternal power supply.

    NETPORT/XTSimple, low cost Ethernet/Art-Net node (9.5" x 1U) for theconversion of Ethernet into 2 independent DMX512+ADNoutputs. It is also the bridge between the Dimmer Manager PC(Ethernet) and ADN, the Advanced Dimmer Network. NETPORT/XT can be inserted anywhere in a DMX+ADN daisy chain.Supplied with external power supply. NETPORT/XT is an intrinsicpart of the Dimmer Manager Kit.

    Dimmer Manager KitThis kit consists of a NETPORT/XT converter and the DimmerManager Software (on CD-ROM) for the ADN managementfunctions. See also page 32.

    NETBUS Remote Dimmer ControllerNETBUS is a small portable Remote Dimmer Controller, to beinserted in the ADN daisy-chain: 23 direct access keys for memory management overview of dimmer status information when used as a

    master of the ADN network access to programming, test and diagnostics functions of

    any dimmer unit

    Advanced Dimmer Network (ADN)Dimmers of the MEMORACK / EURORACK 60 / EURODIM 3families can be networked over the DMX cable via a proprietarybidirectional protocol for the purpose of remote programming,monitoring, fault reporting and memory management from theNETBUS Dimmer Controller or a laptop PC with the DimmerManager kit, which also provides a gateway to an Ethernetnetwork.

    +

  • 17

    ReferenceDescription

    Lighting Technologies

    NETWORKS

    Video NodePortable unitVideo Node with power cable VIDEONODE

    Option

    Wi-Fi Compact Flash Card for wireless operation WIFI/CF

    Ethernet SwitchIntelligent Fast Ethernet Switching hub with 16 ports NET/SWITCH/16P with 24 ports NET/SWITCH/24P

    NETPORTEthernet/ArtNet node with 2 DMX512 outputs NETPORT

    Dimmer Manager Kit, NETPORT XTNETPORT/XT Ethernet/ArtNet node with 2 DMX512 + ADN outputs + DimmerManager Software on CD-ROM KIT/DIMSOFT/PC

    Accessories

    Brackets for 19" rack mounting of one NETPORT or NETPORT/XT (Kit of 2) KIT/FIX/NP/19 Bracket for wall mounting of NETPORT or NETPORT/XT KIT/FIX/NP/WALL

    NETBUS Remote Dimmer ControllerNETBUS Remote dimmer Controller (ADN protocol) NETBUS

    NEW: Video Node for Multiple Screen Monitoring

  • 18Lighting Technologies

    ADB ETHERNET NETWORK

    ADB Ethernet Network is a "plug-and-play" systemdesigned to be very flexible, expandable, easy to configure andinstall. Moreover, the choice of ArtNet, a protocol which is in thepublic domain, allows nodes and programmes from othermanufacturers to be connected to the ADB Ethernet Networkwithout any conversion box and extra costs. Typical examplesare Capture, Sand-Net and WYSIWYG.

    Main Features and User BenefitsADB Ethernet Network allows different parts of a lighting systemto be interconnected. This means that one control desk can beconnected to another one located in a remote location to enablebidirectional data transfer between the two. Both desks couldsend data to a printer. A remote visual display could be providedin the theatre auditorium or TV studio to allow designers andtechnicians to see what is going on.

    Although DMX512 has been remarkably successful in its wideacceptance, it is not always capable of carrying the quantity andvariety of data required in a large modern lighting system. DMXdata can be sent over the Ethernet network allowing a widevariety of lighting information to be distributed around a buildingand then picked off where and when required, this with athroughput typically 400 times higher than via a DMX network.

    Since the ArtNet protocol uses Ethernet as a transport medium,commercially available Ethernet accessories can be integratedin a lighting system.

    One example is the use of a Pocket PC with ADB Wi-Fi softwareto provide wireless bidirectional remote control. Other examplesinclude connecting the Ethernet Network with directional radiofor linking systems in different buildings. It is equally easy toconnect it to a telephone or ISDN for long distance remotecontrol.

    ADB Ethernet Network can also be interconnected with ADN,the Advanced Dimmer Network, via NETPORT/XT DMX nodeand the Dimmer Manager Software (see p. 16).

    Up to 16 independent DMX universes (a total of 8192 DMXaddresses) can be provided on the ADB Ethernet Network withISIS software. Any of these universes can be available on theDMX output of each Ethernet-to-DMX-node.

    Full tracking operation between lighting consoles is anotherfeature of the ADB Ethernet Network. Any action taken on oneconsole is automatically and immediately tracked by the otherones in real time, so that at all times any console can be fullysynchronised with another one. All data, configuration, screeninformation, etc. are transferred practically instantly. In amaster/slave system, should the master break down, theslave will automatically take over without the output stage beingaffected.

    ADB Ethernet Network allows fast data exchange betweendifferent parts of the lighting system. With the ADB multi-tasking concept, saving or loading of shows, sending data toa printer, etc. can be achieved simultaneously. In larger networks,consoles can be connected to dedicated file servers for centralstorage of shows and back-up files.

    With the ADB Ethernet Network, the multi-operatorprogramming capability allows two or more operators fromtwo or more consoles to program a show simultaneously, forexample one for the conventional and one for the intelligentfixtures.

    Subsequently, both parts of the show can be merged into asingle showfile and, more importantly, replayed from just oneconsole. The additional benefit in a system with two consoles isthat the second one can act as a backup during the show.

    Different parts of different shows can be merged into onenew show. This provides a very efficient and fast way to plotnew shows. For example one can load the house patch into ashow that has been plotted in another venue, or an operator canload his profiles into a show plotted by another operator(macros, screen configurations, etc).

    Each node with a video output and ISIS software can act as aremote screen. So the laptops, desktop PCs, and consoles onthe network can be used as remote screens. Up to four screenscan be connected to each network node.

    ISIS software is common to all PHOENIX, PHOENIX/XT andMENTOR lighting control systems. Therefore, all functionsprogrammed on one type of console can be run from any otherone.

    Wi-Fi Wireless Remote Control is added by connectingWireless Access Points to the Ethernet network. HandheldPocket PC's running ADB's Wi-Fi software give you access tochannel and memory management, macro execution, directaccess to dimmers and more! See page 14.

    Does Ethernet replace DMX?NO! Ethernet does not allow daisy-chaining, like DMX512 does,so Ethernets hub-and-spoke distribution involves moreelectronic boxes which could fail.Moreover a UTP/STP cable cannot be longer than 100 m (fromactive part to active part) which means that to cover say 250 mwith Ethernet, two line amplifiers are required, whereas oneDMX cable run could do the job. A good & reliable system willbe a well-thought combination of Ethernet (possibly with fullback-up) and DMX. It may be wise to have a number of DMXuniverses wired directly from the console to e.g. the maindimmers. In the event of a failure in one of the Ethernet buildingblocks, these dimmers will still be under control.

    Technical AssistanceAlthough the ADB Ethernet Network is easy to configure, theoptimum solution for a given application is not always obvious.Our project engineers are here to help you specify the systemwhich will ensure trouble free operation with the best perfor-mance-to-cost ratio.

    Detailed information available on our Website(www.adblighting.com -> ADB Products -> Interface ->Ethernet -> User manual)

  • 19

    ReferenceDescription

    Lighting Technologies

    To DMX console(optional)

    NETPORT/XT

    Dimmer Room

    StageADNDimmerManager

    MENTOR

    NETPORT

    ISIS

    SoftwareEditor

    PHOENIX 5/XT

    PHOENIX 10/XT

    to otherDMXdevices

    to otherDMXdevices

    ControlRoom

    EURODIM 3

    EURORACK 60MEMOFLY

    MEMOPACK 15XT

    Ethernet

    DMX + ADN

    DMX only

    Monitor

    4 x DMX OUT

    1 x DMX IN

    4 x DMX OUT1 x DMX IN

    ETHERNET SWITCH

    ETHERNET / DMX / ADNNETWORK

    Wireless AccessPoints

    POCKET PC TABLET PC

    Monitors

    VIDEO NODE

  • 20Lighting Technologies

    S2MSStage & Studio Management System

    S2MS Stage & Studio Management System - provides acentralised technical management and control solution for theatre,TV and architectural applications. S2MS is unique in its ability towork with DMX, EIB-bus, Ethernet and PLC protocols in additionto the standard analogue and RS232 formats. This allows S2MSto provide central control of existing systems, replacing all of thebespoke systems often used in earlier designs. With new designs,including S2MS at the outset allows the system to be expandedand reprogrammed quickly and easily by the user.

    In a theatre, S2MS centralises control of functions such asAuditorium Lighting, Work Lights whites and blues, CurtainControls, Electrical and Security Monitoring, Proximity and LightLevel Detection, Stage Management Controls, Power Contactors,Non-Dims and much more. Similar systems can be envisaged forTV and Film studios where a greater emphasis can be placedon centralised control of all the different electrical systemstogether with the general lighting.

    Architectural applications might include global lighting controlfor hotels, museums and presentation suites with facilities suchas partition control for multi-room banquet and exhibition cen-tres, security access, control of many separate lighting or audio/video systems allowing centralised master control with remoteslave operation from local control panels. S2MS provides flexibleand cost effective central control of sophisticated systems withintechnical buildings.

    The S2MS System

    S2MS is based around a totally modular concept housed in a 19"cabinet and providing a wide choice of plug-in modules, eachwith a specific functionality. In brief the system consists of acentral power supply and main system unit (MSU) housed in amodular frame where the modules can be inserted, for ex. toaccept DMX inputs (DID) or produce DMX outputs (DOD), toaccept or produce analogue outputs, as links to direct PLCcontrol, for switching audio and video signals, as relay drives forcontactors or other power devices, and more...

    The User Benefits of S2MS

    S2MS is fully user programmable, thus completely eliminatingthe fixed bespoke solution problems. Modules and programmingare "hot pluggable" enabling "live" system alterations andreprogramming. The system supports almost all types of moni-toring devices such as voltage and current transducers, cardreaders, proximity and occupancy detectors... Flexibility is akey feature of the S2MS system design, allowing a very widerange of applications in modern or refurbished buildings.

    A further major benefit of S2MS is the multiplicity of controlsurfaces which can be integrated, such as touch screens, desktop consoles, wall plates, or PC with dedicated software.

    S2MS provides central control of all the general technical facilitiesused in a modern building, thus allowing Stage, Studio Floor,Building and Technical Managers to control the various zones oftheir building, and set them up hourly to suit different show orcommercial requirements. S2MS resolves these issues withinone system whilst having the ability to control products fromother manufacturers.

  • 21

    ReferenceDescription

    Lighting Technologies

    S2MS

  • 22Lighting Technologies

    Low Cost Digital Dimmer PacksPortable and 19" Rackmount Versions

    MICRORACK's, like MEMORACK'scan be supplied in flight cases upon request.

    For an overview and photographs of the range of standardADB touring racks, please visit our website.

    MICROPACK 15 standard version

    Dimensions (mm) : 356 x 143 x 490

    Net weight (kg) : 13

    MICROPACK 15

    6 x 2.3 kW portable and very compact design, Available with all standard European outlets Power supply connection on 3-phase terminal strip Front panel DMX input on XLR5 Optional single phase supply terminal kit Supplied with instruction manual

    MICRORACK 25

    12 x 2.3 kW high density unit designed for insertion in touringracks and for fixed installations in MEMORACK 180 cabinets orstandard 19" racks. Available with AMP, SOCAPEX or twin Wieland outlets Power supply through steel pressure gland (PG) on the rear Front panel DMX input on XLR5 MICRORACK 25 with SOCAPEX or Wieland ST18/3 outputs

    provides P+N+PE per dimmer MICRORACK 25 with 1P+N wiring and AMP outputs provides

    P+N per dimmer; PE to the loads should be wired externally MICRORACK 25 with 1P wiring and AMP outputs provides

    P per dimmer; N and PE to the loads should be wiredexternally

    Supplied with instruction manual

    Dimensions (mm) : 484 x 133 x max. 540

    Net weight (kg) : 17

    MICRORACK 25 (fuse version)

    MICROPACK / MICRORACK

    All-digital dimmer packs/racks combining high quality with lowcost and above average performance, for general purposeapplications in stage and architectural lighting wheneverspace, cost and reliability are the prime considerations.

    Main Features

    3-key keypad, 4-character LED display and user-friendlymenu for easy access to all dimmer functions

    local test of a dimmer (steady or chaser) 10 dimmer laws selectable per dimmer fade smoothing (4000-step resolution) last lighting cue maintained in case of DMX signal interruption permanent storage of all programmed data protection circuitry against accidental 400 V wiring local status reporting: 400 V - overtemperature - fan failure

    - processor check - presence of DMX signal - DMX andanalogue control levels

    first dimmer address selection storage of a lighting cue low noise fan(s) for effective cooling with automatic fan-stop overtemperature protection through gradual dimmer fade

    out

    Technical Specifications

    power supply: 230 V / 400 V Star 3NPE (TN-S), 50/60 Hz individual protection by MCB / 1P (standard version); optional

    1P+N protection with MCB's or HRC fuses with "fuse OK"neon indicator and slot for spare fuse

    suitable for continuous duty at 6 or 12 x 10 A at 35C DMX512/1990 input (XLR5) with galvanic isolation and

    optional analogue inputs 0/+10 V (DB25-S)

  • ReferenceDescription

    23Lighting Technologies

    MICROPACK 15MICRORACK 25

    MICROPACK 156 x 2.3 kW - MCB / 1P - 6 x twin NF/CEBEC sockets MIP 15/62M/C

    6 x 2.3 kW - MCB / 1P - 6 x twin Schuko sockets MIP 15/62M/D

    6 x 2.3 kW - MCB / 1P - 6 x triple Swiss sockets MIP 15/62M/H3

    6 x 2.3 kW - MCB / 1P - 6 x CEE 16 A (P17) sockets MIP 15/62M/CEE

    6 x 2.3 kW - MCB / 1P - 6 x UK 15 A sockets MIP 15/62M/UK

    MICRORACK 2512 x 2.3 kW - MCB / 1P - PG - AMP out (12P - 15 A) - DMX front MIR25/122M/PG/AMP

    12 x 2.3 kW - MCB / 1P - PG - SOCAPEX 419 - DMX front MIR25/122M/PG/SOC

    12 x 2.3 kW - MCB / 1P - PG - twin Wieland 18/3 (parallel) - DMX front MIR25/122M/PG/WI3/P

    12 x 2.3 kW - MCB / 1P - PG - twin Wieland 18/3 (in-series) - DMX front MIR25/122M/PG/WI3/S

    For use in MEMORACK 180 cabinets:12 x 2.3 kW - MCB / 1P - HARTING in - AMP out - DMX rear (IEEE 488) MIR25/122M/HAR/AMP

    Notes

    standard versions supplied without supply cable and XLR5 for other protections, specify the relevant option

    Options and Accessories for MICROPACK 15

    Fuse / 1P+N instead of MCB / 1P protection, for 6 dimmers PROT/FUSE/1P+N/6

    MCB / 1P+N instead of MCB / 1P protection, for 6 dimmers PROT/MCB/1P+N/6

    analogue input 0/+10 V retrofit kit for 6 dimmers KIT/INPUT/ANA/6

    fitted with 2 m supply cable C.ALIM/2/MIC

    230 V single phase supply terminal kit KIT/ALIM/MONO

    brackets for 19" rack mounting (kit) KIT/FIX

    XLR5-M plug for data cable XLR5MX

    XLR5-F receptacle for data cable XLR5FX

    Options and Accessories for MICRORACK 25

    Fuse / 1P+N instead of MCB / 1P protection, for 12 dimmers PROT/FUSE/1P+N/12

    MCB / 1P+N instead of MCB / 1P protection, for 12 dimmers PROT/MCB/1P+N/12

    analogue input 0/+10V retrofit kit for 12 dimmers KIT/INPUT/ANA/12

    fitted with 2 m supply cable C.ALIM/2/MIR

    pair of telescopic guides - 1 required per MIR 25 RAIL/MR30

    XLR5-M plug for data cable XLR5MX

    XLR5-F receptacle for data cable XLR5FX

    AMP output kit: factory-crimped mating connector with

    2 m colour coded cable

    - AMP kit for 12 x 3 kW (1P+N) KIT/AMP/123

  • 24Lighting Technologies

    Intelligent Digital Dimmer PacksPortable Versions

    MEMOPACK

    Portable, intelligent, all-digital dimmer packs, designed forprofessional applications in stage, TV studio and architecturallighting, whenever high performance, quality and reliability arethe prime considerations.Ideal for touring, decentralised dimming or extension of existinginstallations.Available with all standard European outlets.

    Main Features

    5-key keypad, 12 character LED display and user friendlymenus for easy access to all dimmer functions

    set-up functions can be limited to "DMX start address" local controls for creation and storage of 20 lighting cues individual selection of dimmer address (patch), law,

    smoothing and reduction factor fade smoothing (4000-step resolution) 10 dimmer laws (one is user-programmable) Remote programming and monitoring capability

    - from any other dimmer rack (standard)- from the NETBUS Dimmer Controller or a PC with

    the Dimmer Manager kit (options) Extended diagnostics functions (option) professional grade filtering (200 s), for efficient attenuation

    of lamp filament noise protection circuitry against accidental 400 V wiring local status reporting: 400 V - overtemperature - fan failure

    - processor check - presence of DMX signal - DMX andanalogue control levels

    hard-fired thyristors for control of tungsten halogen lamps,resistive and inductive loads, transformer-fed low voltagelamps, fluorescent lighting with suitable ballasts

    local test of a dimmer (steady, flash or chaser) automatic self-test capability programmable response to a DMX failure low noise fan for effective cooling with automatic fan-stop overtemperature protection through gradual dimmer fade out

    Technical Specifications

    power supply: 230 V / 400 V Star 3NPE (TN-S), 50/60 Hz individual protection by MCB/1P (standard version); optional

    1P+N protection with MCB's or HRC fuses with "fuse ok"neon indicator and slot for spare fuse

    suitable for continuous duty (3 kW or 5 kW per dimmer)at 35 C

    DMX512/1990 input (XLR5) with galvanic isolation + ADNbidirectional serial port (EIA/RS-485)Optional analogue inputs 0/+10 V (DB25-S)

    Architectural Applications

    The KIT/INPUT/ANA/24 analogue input option allows remotecontrol by means of analogue control desk (0/+10V), or 3-position selector switch (up - down - steady), one switch

    can control one or several dimmers, or remote storage, playback and dimming of the

    20 memories; direct access, one switch per memory

    Dimensions (mm) : 432 x 143 x 490Net weight (kg) : 17

    MEMOPACK 15XT - 6 x 3 kW with RCD/MEMO option

    MEMOPACK 15 XT

    2 configurations : 6 x 3 kW or 3 x 5 kW power supply on CEE 32A ( P17) connector on the rear

    except when fitted with 6 twin UK 15A sockets front panel DMX input on XLR5 optional single phase supply terminal kit optional MCB+RCD protection per dimmer supplied with instruction manual.

    MEMOPACK 30

    2 configurations : 12 x 3 kW or 6 x 5 kW equipped with 2 m power supply cable front panel DMX input on XLR5 supplied with instruction manual

    MEMOPACK 30 - 12 x 3 kW

    Dimensions (mm) : 680 x 190 x 535Net weight (kg) : 27

    Advanced Dimmer Network (ADN)

    Dimmers of the MEMOPACK / MEMORACK / EURORACK 60/ EURODIM 3 families can be networked over the DMX cablevia a proprietary bidirectional protocol for the purpose ofremote programming, monitoring, fault reporting and memorymanagement from the NETBUS Dimmer Controller or a laptopPC with the Dimmer Manager kit, which also provides agateway to an Ethernet network (see p. 32).

  • ReferenceDescription

    25Lighting Technologies

    MEMOPACK 15 XT MEMOPACK 30

    MEMOPACK 15 XT6 x 3 kW - MCB / 1P - 6 x twin NF/CEBEC sockets MP15/XT/63M/C6 x 3 kW - MCB / 1P - 6 x twin Schuko sockets MP15/XT/63M/D6 x 3 kW - MCB / 1P - 6 x triple Swiss sockets MP15/XT/63M/H36 x 3 kW - MCB / 1P - 6 x CEE 16 A (P17) sockets MP15/XT/63M/CEE6 x 3 kW - MCB / 1P - 6 x twin UK 15 A sockets MP15/XT/63M/UK2

    (no CEE inlet, fitted with 2 m supply cable)3 x 5 kW - MCB / 1P - 3 x CEE 32 A MP15/XT/35M/CEE

    MEMOPACK 3012 x 3 kW - MCB / 1P - 12 x twin NF/CEBEC sockets MP30/123M/C12 x 3 kW - MCB / 1P - 12 x twin Schuko sockets MP30/123M/D12 x 3 kW - MCB / 1P - 12 x triple Swiss sockets MP30/123M/H312 x 3 kW - MCB / 1P - 12 x CEE 16 A (P17) sockets MP30/123M/CEE 6 x 5 kW - MCB / 1P - 6 x CEE 32 A MP30/65M/CEE

    Notes: for other protections, specify the relevant option true 2P protection upon request other output sockets upon request for 19'' rack mounting: use MEMORACK

    Options and Accessories

    Fuse/1P+N instead of MCB/1P protection, for 12 dimmers PROT/FUSE/1P+N/12 Fuse/1P+N instead of MCB/1P protection, for 6 dimmers PROT/FUSE/1P+N/6 Fuse/1P+N instead of MCB/1P protection, for 3 dimmers PROT/FUSE/1P+N/3 MCB/1P+N instead of MCB/1P protection, for 12 dimmers PROT/MCB/1P+N/12 MCB/1P+N instead of MCB/1P protection, for 6 dimmers PROT/MCB/1P+N/6 MCB/1P+N instead of MCB/1P protection, for 3 dimmers PROT/MCB/1P+N/3 analogue input 0/+10 V retrofit kit, for 6 dimmers KIT/INPUT/ANA/6 analogue input 0/+10 V retrofit kit, for 12 dimmers KIT/INPUT/ANA/12 for remote memory control:

    analogue input 0/+10 V retrofit kit with 24 inputs KIT/INPUT/ANA/24 NETBUS Remote Dimmer Controller NETBUS Dimmer Manager kit including NETPORT/XT converter and software for PC KIT/DIMSOFT/PC extended diagnostics functions for MEMOPACK 30 DIAG/MEMO 30 XLR5-M plug for data cable XLR5MX XLR5-F receptacle for data cable XLR5FX

    Options for MEMOPACK 15/XT only

    230 V single phase supply terminal kit KIT/ALIM/MONO fitted with 2 m supply cable instead of CEE 32 power inlet C.ALIM/2/MEMO supply RCD 4P - 30 mA, compulsory for IT/TT supply RCD/MEMO RCD+MCB/1P+N - 30 mA - 6kA per dimmer for 6 x 3 kW dimmers RCD+MCB/63 RCD+MCB/1P+N - 30 mA - 6kA per dimmer for 3 x 5 kW dimmers RCD+MCB/35 extended diagnostics functions DIAG/MEMO 15 Star/Delta power supply upon request

  • 26Lighting Technologies

    Intelligent Digital Dimmer Racksfor 19" Rack Mounting

    MEMORACK 15

    Modified construction of MEMOPACK 15 XT, for 19" rackmounting - 6 x 3 kW or 3 x 5 kW. available with all standard European outlets power supply on HARTING socket or CEE32A (P17)

    connector on the rear, except when fitted with twin UK 15A front panel DMX input on XLR5 optional MCB+RCD protection per dimmer instruction manual

    Dimensions (mm) : 484 x 133 x max. 540Net weight (kg) : 18

    MEMORACKIntelligent, all-digital dimmer racks designed for professionalapplications in stage, TV studio, architectural and locationlighting, whenever high performance, quality, endurance andreliability are the prime considerations. Specifically designed forheavy duty touring racks and for fixed installations inMEMORACK 180 cabinets or standard 19" racks.

    Main Features 5-key keypad, 12 character LED display and user friendly

    menus for easy access to all dimmer functions Set-up functions can be limited to "DMX start address" local controls for creation and storage of 20 lighting cues individual selection of dimmer address (patch), law,

    smoothing and multiplication factor fade smoothing (4000-step resolution) 10 dimmer laws (one is user-programmable) Remote programming and monitoring capability

    - from any other dimmer rack (standard)- from the NETBUS Dimmer Controller or a PC with the

    Dimmer Manager kit (options) Extended diagnostics functions (option) professional grade filtering (200 s), for efficient attenuation

    of lamp filament noise protection circuitry against accidental 400 V wiring local status reporting: 400 V - overtemperature - fan failure

    - processor check - presence of DMX signal - DMX andanalogue control levels

    hard-fired thyristors for control of tungsten halogen lamps,resistive and inductive loads, transformer-fed low voltagelamps, fluorescent lighting with suitable ballasts

    local test of a dimmer (steady, flash or chaser) automatic self-test capability programmable response to a DMX failure low noise fan(s) for effective cooling, with automatic fan-stop overtemperature protection through gradual dimmer fade out

    Technical Specifications

    power supply: 230 V / 400 V Star 3NPE (TN-S), 50/60 Hz individual protection by MCB/1P (standard version), optional

    1P+N protection with MCB's or HRC fuses with "fuse OK"neon indicator and slot for spare fuse

    suitable for continuous duty (3 kW or 5 kW per dimmer) at35 C; MEMORACK 30: max. total load 30 kW

    DMX512/1990 input (XLR5) with galvanic isolation + ADNbidirectional serial port (EIA/RS-485)Optional analogue inputs 0/+10 V (DB25-S)

    dual DMX input with patch upon request for standard MEMORACK, PE to the loads should be wired

    externally

    Architectural Applications

    The KIT/INPUT/ANA/24 analogue input option allows remotecontrol by means of analogue control desk (0/+10V), or 3-position selector switch (up - down - steady), one switch

    can control one or several dimmers, or remote storage, playback and dimming of the

    20 memories; direct access, one switch per memory

    MEMORACK 30

    For 19" rack mounting - 12 x 3 kW or 6 x 5 kW or 3 x 12 kW. power supply on HARTING socket 4 x 80 A + PE rear panel DMX input on XLR5

    optional: front panel DMX input on XLR5 rear panel power outlets on HARTING connectors instruction manual

    Note: For mounting in touring racks, specify MEMORACK 30/FLY.For an overview and photographs of the range ofstandard ADB touring racks, please visit our website.

    Dimensions (mm) : 484 x 133 x max. 540Net weight (kg) : 20

    MEMORACK 15 - 6 x 3 kW with RCD + MCB

    Advanced Dimmer Network (ADN)

    Dimmers of the MEMOPACK / MEMORACK / EURORACK 60/ EURODIM 3 families can be networked over the DMX cablevia a proprietary bidirectional protocol for the purpose ofremote programming, monitoring, fault reporting and memorymanagement from the NETBUS Dimmer Controller or a laptopPC with the Dimmer Manager kit, which also provides agateway to an Ethernet network (see p. 32).

  • ReferenceDescription

    27Lighting Technologies

    MEMORACK 15MEMORACK 30

    MEMORACK 156 x 3 kW - MCB/1P - 6 x twin NF/CEBEC sockets MR15/63M/C6 x 3 kW - MCB/1P - 6 x twin Schuko sockets MR15/63M/D6 x 3 kW - MCB/1P - 6 x triple Swiss sockets MR15/63M/H36 x 3 kW - MCB/1P - 6 x CEE 16 A (P17) sockets MR15/63M/CEE6 x 3 kW - MCB/1P - HARTING in - HARTING out MR15/63M/HAR6 x 3 kW - MCB/1P - 6 x twin UK 15 A sockets MR15/63M/UK2

    (no CEE inlet, fitted with 2 m supply cable)

    3 x 5 kW - MCB/1P - 3 x CEE 32 A MR15/35M/CEE3 x 5 kW - MCB/1P - HARTING in - HARTING out MR15/35M/HAR

    MEMORACK 3012 x 3 kW - MCB/1P - HARTING in - HARTING out MR30/123M/HAR 6 x 5 kW - MCB/1P - HARTING in - HARTING out MR30/65M/HAR 3 x 12 kW - MCB/2P - HARTING in - HARTING out MR30/312/HARNotes : specify DMX front or DMX rear

    for other protections specify the relevant option other output sockets upon request analogue inputs only possible with DMX front

    MEMORACK 30/FLY (Special for touring racks)Power supply on HARTING - DMX rear (XLR5) - Output voltage neon indicators12 x 3 kW - MCB/1P+N - HARTING in - 2 x SOCAPEX 419 out MR30/FLY/123/SOC 6 x 5 kW - MCB/1P+N - HARTING in and HARTING out MR30/FLY/65/HAR

    Common Options and Accessories Fuse/1P+N instead of MCB/1P protection, for 12 dimmers PROT/FUSE/1P+N/12 Fuse/1P+N instead of MCB/1P protection, for 6 dimmers PROT/FUSE/1P+N/6 Fuse/1P+N instead of MCB/1P protection, for 3 dimmers PROT/FUSE/1P+N/3 MCB/1P+N instead of MCB/1P protection, for 12 dimmers PROT/MCB/1P+N/12 MCB/1P+N instead of MCB/1P protection, for 6 dimmers PROT/MCB/1P+N/6 MCB/1P+N instead of MCB/1P protection, for 3 dimmers PROT/MCB/1P+N/3 analogue input 0/+10 V retrofit kit, for 6 dimmers KIT/INPUT/ANA/6 analogue input 0/+10 V retrofit kit, for 12 dimmers KIT/INPUT/ANA/12 for remote memory control:

    analogue input 0/+10 V retrofit kit with 24 inputs KIT/INPUT/ANA/24 NETBUS Remote Dimmer Controller NETBUS Dimmer Manager kit including NETPORT/XT converter and software for PC KIT/DIMSOFT/PC pair of telescopic guides - 1 required per MR30 or MR15 RAIL/MR30 XLR5-M plug for data cable XLR5MX XLR5-F receptacle for data cable XLR5FX

    Options for MEMORACK 15 only fitted with 2 m supply cable instead of CEE 32 A power inlet C.ALIM/2/MEMO supply RCD 4P - 30 mA, compulsory for IT/TT supply RCD / MEMO RCD+MCB/1P+N-30mA-6kA per dimmer for 6 x 3 kW dimmers RCD+MCB/63 RCD+MCB/1P+N-30mA-6kA per dimmer for 3 x 5 kW dimmers RCD+MCB/35 extended diagnostics functions DIAG /MEMO 15 Star/Delta power supply upon request

    Option for MEMORACK 30 only extended diagnostics functions DIAG /MEMO 30

    NEW: Outputs on HARTING Sockets

  • 28Lighting Technologies

    Low Cost Digital Dimmer Rackfor Wall Mounting

    EURORACK 50

    24 x 2.3 kW, very compact, all-digital dimmer rack for wallmounting, combining high quality with low cost and aboveaverage performance, for general purpose applications in stageand architectural lighting, whenever space, cost and reliabilityare the prime considerations.

    Main Features

    3-key keypad, 4-character LED display and user-friendlymenu for easy access to all dimmer functions

    local test of a dimmer (steady or chaser) 10 dimmer laws selectable per dimmer fade smoothing (4000-step resolution) last lighting cue maintained in case of DMX signal interruption permanent storage of all programmed data protection circuitry against accidental 400 V wiring local status reporting: 400 V - overtemperature - fan failure

    - processor check - presence of DMX signal - DMX andanalogue control levels

    first dimmer address selection storage of a lighting cue low noise fans for effective cooling with automatic fan-stop overtemperature protection through gradual dimmer fade

    out

    Dimensions (mm) : 1022 x 555 x 132

    Net weight (kg) : 34

    Technical Specifications

    power supply: 230 V / 400 V Star 3NPE (TN-S), 50/60 Hz individual protection by MCB / 1P (standard version); optional

    1P+N protection with MCB's or HRC fuses with "fuse OK"neon indicator and slot for spare fuse

    optional RCD supply protection per group of 4 or 8dimmers

    suitable for continuous duty at 24 x 10 A at 35 C DMX512/1990 input (XLR5) with galvanic isolation and

    optional analogue inputs 0/+10 V (DB25-S) bottom panel fitted with PG31 steel pressure gland for

    supply cable, XLR5 connectors for DMX signal, and 24holes for output cables.

    Supplied with: a kit of 24 universal seals for the output cables (version

    without patch only) instruction manual

    Installation

    EURORACK 50 is shipped as a complete unit, factory testedand ready for installation. No further assembling is required onsite.EURORACK 50 with Hard Patch

    The lower front panel provides a hard patch available with mostof the standard European power outlets.

  • ReferenceDescription

    29Lighting Technologies

    EURORACK 50

    EURORACK 50 without hard patch24 x 2.3 kW - MCB/1P ER 50/242M

    EURORACK 50 with hard patch24 x 2.3 kW - MCB/1P - 24 x twin NF/CEBEC sockets ER 50/242M/C24 x 2.3 kW - MCB/1P - 24 x twin Schuko sockets ER 50/242M/D24 x 2.3 kW - MCB/1P - 24 x triple Swiss sockets ER 50/242M/H324 x 2.3 kW - MCB/1P - 24 x CEE 16A (P17) sockets ER 50/242M/CEE24 x 2.3 kW - MCB/1P - 24 x dual IEC 10A sockets ER 50/242M/IEC

    Notes: for other protections specify the relevant option other output sockets upon request

    Options and Accessories

    MCB/1P+N instead of MCB/1P protection for 24 dimmers PROT/MCB/1P+N/24 Fuse/1P+N instead of MCB/1P protection for 24 dimmers PROT/FUSE/1P+N/24 RCD - 30 mA (1P+N) supply protection per group of 4 dimmers compulsory

    for IT/TT supply. Required quantity: 6 RCD10/ER50 RCD - 30 mA (1P+N) supply protection per group of 8 dimmers compulsory

    for IT/TT supply. Required quantity: 3 RCD20/ER50 analogue input 0/+10V retrofit kit with 24 inputs KIT/INPUT/ANA/24 stand-off brackets for 10 cm trunking space behind the rack ARC/ERACK

    The most cost effective Dimmer

  • 30Lighting Technologies

    Intelligent Digital Dimmer Rackfor Wall Mounting

    EURORACK 60

    Very compact, intelligent, all-digital dimmer rack for wallmounting, designed for professional applications in stage, TVstudio and architectural lighting, whenever high performance,space and cost are the prime considerations.

    Standard configurations: 24 x 3 kW 12 x 5 kW (12 x 3 kW) + (6 x 5 kW) 12 x 3 kVA industrial contactors

    Main Features

    5-key keypad, 12 character LED display and user friendlymenus for easy access to all dimmer functions

    set-up functions can be limited to "DMX start address" local controls for creation and storage of 20 lighting cues. individual selection of dimmer address (patch), law,

    smoothing and multiplication factor fade smoothing (4000-step resolution) 10 dimmer laws (one is user-programmable) Remote Programming and Monitoring capability

    - from any other dimmer rack (standard)- from the NETBUS Dimmer Controller or a PC with

    the Dimmer Manager kit (options) Extended diagnostics functions (option) professional grade filtering (200 s), for efficient attenuation

    of lamp filament noise protection circuitry against accidental 400 V wiring local status reporting: 400 V - overtemperature - fan failure

    - processor check - presence of DMX signal - DMX andanalogue control levels

    hard-fired thyristors for control of tungsten halogen lamps,resistive and inductive loads, transformer-fed low voltagelamps, fluorescent lighting with suitable ballasts

    heavy duty contactors for non-dimmable and special loads(HMI,)

    local test of a dimmer (steady, flash or chaser) automatic self-test capability programmable response to a DMX failure low noise fans for effective cooling with automatic fan-stop overtemperature protection through gradual dimmer fade out

    Technical Specifications

    power supply: 230 V / 400 V Star 3NPE (TN-S), 50/60 Hz individual protection by MCB/1P (standard version), optional

    1P+N protection with MCB's or HRC fuses with "fuse OK"neon indicator and slot for spare fuse

    optional MCB+RCD protection per dimmer optional main isolator switch 4P-100A suitable for continuous duty (3 kW or 5 kW per dimmer),

    with 60 kW max. load at 35 C DMX 512/1990 input on screw terminals + ADN bidirectional

    serial port (EIA/RS-485). Optional analogue inputs 0/+10 V(DB25S)

    optional dual DMX input, each with patch galvanic isolation on the DMX input

    Dimensions (mm) : 1022 x 555 x 132

    Net weight (kg) : 43

    Installation

    EURORACK 60 is shipped as a complete unit, factory testedand ready for installation. No further assembling is required onsite.

    The blank cable entry panel at the bottom is removable. Option:extra installation hardware and bottom panel fitted with 27universal seals for output and data cables, and a steel PG31supply cable gland.

    Architectural Applications

    The analogue input option allows remote control by means of analogue control desk (0/+10V), or 3-position selector switch (up - down - steady), one switch

    can control one or several dimmers, or remote storage, playback and dimming of the

    20 memories; direct access, one switch per memory

    Advanced Dimmer Network (ADN)

    Dimmers of the MEMOPACK / MEMORACK / EURORACK 60/ EURODIM 3 families can be networked over the DMX cablevia a proprietary bidirectional protocol for the purpose ofremote programming, monitoring, fault reporting and memorymanagement from the NETBUS Dimmer Controller or a laptopPC with the Dimmer Manager kit, which also provides agateway to an Ethernet network (see p. 32).

  • ReferenceDescription

    31Lighting Technologies

    EURORACK 60

    EURORACK 6024 x 3 kW - MCB/1P ERACK 60/243M12 x 5 kW - MCB/1P ERACK 60/125M(12 x 3 kW) + (6 x 5 kW) - MCB/1P ERACK 60/123+65M12 x 3 kW - MCB/1P ERACK 60/123M 6 x 5 kW - MCB/1P ERACK 60/65M12 x 3 kVA industrial contactors - MCB/1P ERACK 60/123M/SW

    Notes: for other protections specify the relevant option true 2P protection upon request

    Options and Accessories

    MCB/1P+N instead of MCB/1P protection-for 24 dimmers PROT/MCB/1P+N/24-for 18 dimmers PROT/MCB/1P+N/18-for 12 dimmers PROT/MCB/1P+N/12-for 6 dimmers PROT/MCB/1P+N/6

    Fuse/1P+N instead of MCB/1P protection-for 24 dimmers PROT/FUSE/1P+N/24-for 18 dimmers PROT/FUSE/1P+N/18-for 12 dimmers PROT/FUSE/1P+N/12-for 6 dimmers PROT/FUSE/1P+N/6

    RCD - 30 mA (1P+N) RCD10/ERACKsupply protection per group of 10 kW (4 x 3 kW or 2 x 5 kW)compulsory for IT/TT supply. Required quantity: 6 for 60 kW

    RCD - 30 mA (3P+N) RCD30/ERACKsupply protection per group of 30 kW (12 x 3 kW or 6 x 5 kW)Required quantity: 2 for 60 kW

    RCD+MCB/1P+N-30mA - 6kA per dimmer- for 24 x 3 kW dimmers RCD+MCB/243- for 12 x 5 kW dimmers RCD+MCB/125- for 12 x 3 kW dimmers RCD+MCB/123- for (12 x 3 kW) + (6 x 5 kW) dimmers RCD+MCB/123+65- for 6 x 5 kW dimmers RCD+MCB/65

    analogue input 0/+10V retrofit kit with 24 inputs KIT/INPUT/ANA/24 NETBUS Remote Dimmer Controller NETBUS Dimmer Manager kit including NETPORT/XT converter and software for PC KIT/DIMSOFT/PC extended diagnostics functions DIAG/ERACK 60 dual DMX input on screw terminals, installed 2 DMX/ERACK dual DMX input retrofit kit (CPU board with data cables) KIT/2DMX/ERACK stand-off brackets for 10 cm trunking space behind the rack ARC/ERACK cable entry panel with 27 universal entry seals and PANN.PG/ERACK

    a steel PG31 cable gland + additional cable support rails main isolator switch 4P - 100 A INP.SWITCH/ERACK Star/Delta power supply upon request

  • 32Lighting Technologies

    MEMORACK 180

    180/220kW, high performance, all-digital dimming systemconsisting of up to six independent MEMORACK 30 modules,mounted on telescopic guides and easily disconnectable.These modules are self-contained 19" x 3U units, configured as12 x 3 kW, 6 x 5 kW, or 3 x 12 kW.The MEMORACK 180 system is intended for professionalapplications in stage and studio lighting whenever individualplug-in modularity is not required. The dimmer modules caneasily be removed and installed in touring racks.

    Available in several configurations: 72 x 3 kW 36 x 5 kW combinations of 12 x 3 kW and 6 x 5 kW modules.

    Alternatively, MEMORACK 180 can be equipped with up to8 MICRORACK 25 or MEMORACK 15 modules for a totalof 96 x 2.3 kW or 48 x 3 kW dimmers.

    Main Dimmer Features & Technical Specifications

    See MEMORACK 30, or MEMORACK 15, or MICRORACK 25sections in this catalogue.

    Intelligent Digital Dimmer Rackin stand-alone Cabinet

    Electrical Cabinet Protection

    Each dimmer module has HRC fuse supply protection (3P or3P+N) located on the front panel. Optional: MCB or RCD+MCBsupply protection instead of HRC fuse

    To order a MEMORACK 180

    A MEMORACK 180 cabinet can be equipped with pre-wiredframes adapted to the selected dimmer modules.Blank panels (3U) are available for non-used frames.The complete description of a MEMORACK 180 will specify: the cabinet the pre-wired frames the optional power supply protections the dimmer modules, MEMORACK 30, MEMORACK 15,

    MICRORACK 25, and their individual protections andoptions.

    NETBUS

    Advanced Dimmer Network (ADN)Dimmers of the MEMOPACK / MEMORACK / EURORACK 60/ EURODIM 3 families can be networked over the DMX cablevia a proprietary bidirectional protocol for the purpose ofremote programming, monitoring, fault reporting and memorymanagement from the NETBUS Dimmer Controller or a laptopPC with the Dimmer Manager kit, which also provides agateway to an Ethernet network.

    NETBUS (option)NETBUS is a small (340 x 285 x 75 mm), portable, low costRemote Dimmer Controller which can be inserted anywherein the ADN network and provides: 23 direct access keys for storing and replaying the lighting

    cues in the dimming system remote access to all dimmer functions overview of centralised error messagesNETBUS is particularly useful for architectural lightingsequences.

    Dimmer Manager Kit (option)The kit consists of a NETPORT/XT Ethernet to DMX+ADNconverter (see p. 16) and Dimmer Manager, a remoteprogramming and reporting software for PC. Its graphicaluser interface gives an overview of, and remote access to allthe dimmers in the most complex installation. DimmerManager provides a system-wide overview of events such asabsent dimmer units, status of CPU and back-up CPU, errorand alarm messages (fan failure, temperature, missingphase...), start of Scan Load routine, reporting of actual loadper dimmer. Dimmer system management functions includedownloading/uploading of dimmer parameters, on-line andoff-line editing, graphical editing and library of custom dimmerlaws, and creating back-ups of system configurations e.g.per show or per venue.

    Dimensions (mm) :905 x 705 x 1895

    Net Weight (kg) :+/- 180 (without dimmer modules)

    MEMORACK 180 with 6 MR30 modules

  • ReferenceDescription

    33Lighting Technologies

    MEMORACK 180 Cabinet39 U cabinet for 19" pre-wired frames, a cabling compartment with front access,supply busbars, internal DMX distribution. for max. 6 frames (MR30) MR180/630 for max. 8 frames (MR15 or MIR25) MR180/825

    Each pre-wired frame includes power supply protection by HRC fuses internal supply and output wiring output terminals in the cabling compartment pair of telescopic guides

    3P protected frame for MR 30 - 12 x 3 kW - 1P or MIR 25 - 12 x 2.3 kW - 1P MR180/R12/3S for MR 30 - 6 x 5 kW - 1P MR180/R6/3S

    3P+N protected frame for MR 30 - 12 x 3 kW - 1P or MIR 25 - 12 x 2.3 kW - 1P MR180/R12/4S for MR 30 - 6 x 5 kW - 1P MR180/R6/4S

    3P+N protected frame for MR 30 - 12 x 3 kW - 1P+N or MIR 25 - 12 x 2.3 kW - 1P+N MR180/R12/4SN for MR 30 - 6 x 5 kW - 1P+N MR180/R6/4SN

    Blank panel (3 U) for non-used frame MR180/RACK0

    Options for power supply protection (one per frame) MCB (63 A; 10 kA) instead of HRC fuses MR180/MCB/R RCD + MCB (30 mA; 63 A; 10 kA) instead of HRC fuses MR180/RCD+MCB/R

    4P main isolator switch suitable for on-load disconnection INP.SWITCH/MR180of a MR180/630 cabinet

    Residual current monitoring and alarm module DD2 / LEAK.ALARM(1 module per cabinet) measures and transmits true r.m.s. value of residual(earth leakage) current with non-latched or latched alarm. Can also be integratedinto the main switching board for monitoring other equipment and dimmers(MEMOPACK, EURORACK)

    See MEMORACK 30, MEMORACK 15, or MICRORACK 25 for dimmer selection and dimmer protection options for diagnostic and remote control options

    Accessories

    The following accessories are available for integration of the dimmer modules intoother cabinets, touring racks or 19" racks;they are already included in the frames MR180/R pair of telecopic guides - 1 required per module RAIL/MR30 Harting (4P+PE; F) connector + locking screws - 1 required per module HART.80F

    MEMORACK 180

  • 34Lighting Technologies

    Intelligent Digital Dimming Systemwith individual plug-in Modules

    EURODIM 3

    Cabinets with Crate Protection

    High-density 270 kW cabinets with all digital, plug-in dimmermodules for professional theatre and televisioninstallations. For accurate, stable and reliable performance,combined with comprehensive remote programming anddiagnostics functions. Two cabinet sizes are proposed:DD3 180/270/P divided into max. 4 crates for up to 72 x 3or 5 kW dimmers, and DD3 225/270/P divided into max. 5crates for up to 90 x 3 or 5 kW dimmers.Individual crate protection (45 kW) for maximum safetyand operating comfort: 3P or 4P HRC fuses (100 kA), orMCB, or MCB+RCD. Optional MCD+RCD protection pergroup of 6 x 3 kW or 3 x 5 kW.

    Standard configurations 36 or 45 dual 3 kW modules 36 or 45 single 5 kW modules 36 or 45 dual 5 kW modules depending on cabinet size combinations of 3 kW, 5 kW and 10 kW dimmers

    Set-up functions 5-key keypad, 12-character LED display and user-

    friendly menu for easy access to all dimmer functions 10 selectable dimmer laws: linear r.m.s. voltage, linear

    r.m.s. to 120V, TV laws (BBC, TV1, TV2), non-dim withhysteresis, fluorescent, linear r.m.s. voltage withpreheating, square law, user-programmable law

    voltage reduction factor for extended lamp life orvariable load cable length compensation

    4000-step fade resolution, for very smooth fades global or individual programming of dimmer law,

    patching, voltage reduction factor and smoothing Restore House Patch function recalls a preferred DMX

    patch creation and storage of 20 lighting cues (19 + Priority)

    each with fade and wait times, for back-up cues,working lights, or stand-alone operation

    after loss of DMX: maintain last levels, or wait and fadeto one of the internal cues, or wait and fade to black

    all programmed data saved for unlimited time

    Filtering TV broadcast quality filtering (BBC, TDF) with large

    toroidal filter chokes, 400 s rise-time (10% to 90%) professional quality filtering (200 s) as an alternativeTypes of loads hard-fired thyristors for the control of 230 V tungsten

    halogen lamps, resistive and inductive loads,transformer-fed low voltage lamps, fluorescent lightingwith suitable ballasts

    cold tungsten lamps allowed without damage to thethyristors

    relay, bypass and feed-through modules are availablefor non-dimmable loads

    Extended diagnostics functions (see data sheet)

    Technical Specifications Power supply: star 3 NPE 400 (TN-S), 198 V to 264 V, 50/60 Hz

    Delta supply upon request Max. load: 45 kW per crate Rated load of dimmer modules (continuous duty at 35 C ambient)

    2 x 3 kW; 1 x 5 kW; 2 x 5 kW; 1 x 10 kW; 1 x 3 kW (Fluo) Control inputs: two DMX512/1990 digital inputs each with individual

    patch + ADN bidirectional serial port (EIA/RS-485)

    Individual dimmer protection by an MCB or an HRC fuse (100 kA), with fuse OK neon indicator;

    3 options: 1P, 1P+N or 2P optional RCD protection per dimmer

    Ventilation assisted ventilation by means of 6 low noise fans regulated airflow and automatic stop the performance of each fan is monitored individually

    Reliability & Safety modules designed for continuous duty at full rated load double control electronics provide instant back-up (option) a 3-phase power supply for the electronics and fans guarantees

    continuity of control and full ventilation should one supply phase fail opto-isolated DMX and ADN inputs

    Networking, remote controlSee MEMORACK 180, page 32.

    DD3 225/270 P cabinet with 90 x 3 kW dimmers& optional back-up electronics

  • ReferenceDescription

    35Lighting Technologies

    EURODIM 3

    EURODIM 3 with Crate Protection 180/270 kW cabinet with central control electronics and 2 DMX inputs,

    for max. 4 protected power crates DD3/180/270/P 225/270 kW cabinet with central control electronics and 2 DMX inputs,

    for max. 5 protected power crates DD3/225/270/P

    Double control electronics for instant back-up (Retrofit not possible) DD3/ER

    3P fuse protected power crate (empty) for 1P protected dimmers 18 x 3 kW 9 dual 3 kW modules DD3/R18 x 3/3S 18 x 5 kW 9 dual 5 kW modules DD3/R18 x 5/3S 9 x 5 kW single modules DD3/R9/3S (3 x 5 kW) + (3 x 10 kW) single modules DD3/R3/3S

    3P+N fuse protected power crate (empty) for 1P protected dimmers 18 x 3 kW 9 dual 3 kW modules DD3/R18 x 3/4S 18 x 5 kW 9 dual 5 kW modules DD3/R18 x 5/4S 9 x 5 kW single modules DD3/R9/4S (3 x 5 kW) + (3 x 10 kW) single modules DD3/R3/4S

    3P+N fuse protected power crate (empty) for 1P+N and 2P protected dimmers 18 x 3 kW 9 dual 3 kW modules DD3/R18 x 3/4B 18 x 5 kW 9 dual 5 kW modules DD3/R18 x 5/4B 9 x 5 kW single modules DD3/R9/4B (3 x 5 kW) + (3 x 10 kW) single modules DD3/R3/4B

    Note: Power crates with a mix of 3 kW and 5 kW modules upon request

    Blank panel for non-wired crate DD3/RACK 0

    Options

    Circuit breaker (MCB) crate protection instead of HRC fuses for /3S crate DD3/MCB.RACK/3S for /4S crate DD3/MCB.RACK/4S for /4B crate DD3/MCB.RACK/4B

    RCD protection per crate - 30 mA (requires MCB crate protection) DD3/RCD.RACK

    RCD protection per dimmer - 30 mA - 6 kA for 3 kW dimmers DD3/RCD/3KW for 5 kW dimmers DD3/RCD/5KW for 10 kW dimmers DD3/RCD/10KW

    MCB+RCD protection per group of 6 x 3 kW or 3 x 5 kW (upon request)

    Residual current monitoring and alarm module DD3/LEAK.ALARM(1 or 3 modules per cabinet) measures and transmits true r.m.s. value of residual(earth leakage) current, with non-latched or latched alarm.

    Advanced Dimmer Network (ADN) NETBUS Remote Dimmer Controller NETBUS Dimmer Manager kit including NETPORT/XT converter and software for PC KIT/DIMSOFT/PC

    Note: EURODIM 2 cabinets with full diagnostics are still available upon request.

  • 36Lighting Technologies

    Intelligent Digital Dimming Systemwith individual plug-in Modules

    10 kW Dimmer Module (400 s)

    5 kW Dimmer Module (400 s)

    2 x 3 kW Dimmer Module (400 s)

    Plug-in Digital Dimmer Modules

    2 x 5 kW Dimmer Module (400 s)

    EURODIM 3

    Cabinets without Crate Protection

    High-density 270 kW cabinets with all digital, plug-in dimmermodules for professional theatre and televisioninstallations. For accurate, stable and reliable performance,combined with comprehensive remote programming anddiagnostics functions.

    Two cabinet sizes are proposed:DD3 180/270/NP divided into max. 5 crates for up to90 x 3 or 5 kW dimmers, and DD3 225/270/NP divided intomax. 6 crates for up to 108 x 3 or 5 kW dimmers.

    Standard configurations 45 or 54 dual 3 kW modules 45 or 54 single 5 kW modules 45 or 54 dual 5 kW modules

    depending on cabinet size combinations of 3 kW, 5 kW and 10 kW dimmers

    General CharacteristicsSame as EURODIM 3 with crate protection (see page 34),except: Max. load: 400A/270 kW per cabinet. Cabinet input protection by HRC fuses (100 kA) with

    or without 4P mains isolator switch (options).

    Networking, remote controlSee MEMORACK 180, page 32.

    Proven Design and Reliability

    The generously sized heatsink provides efficientcooling, and its large thermal inertia has a stabilisingeffect on the temperature.Hot patching of modules is allowed, thanks to apower connector with sequenced mating of thecontacts.Three indicators provide a quick overview of thedimmer status: fuse OK/MCB on, output voltage,output current.

    DD3 225/270 NP cabinet with 108 x 5 kW dimmers& optional back-up electronics

  • ReferenceDescription

    37Lighting Technologies

    EURODIM 3

    EURODIM 3 without Crate Protection 180/270 kW cabinet with central control electronics and 2 DMX inputs,

    for max. 5 non-protected power crates DD3/180/270/NP 225/270 kW cabinet with central control electronics and 2 DMX inputs,

    for max. 6 non-protected power crates DD3/225/270/NP

    Double control electronics for instant back-up DD3/ER(Retrofit not possible)

    Non-protected power crate (empty) for 1P protected dimmers 18 x 3 kW 9 dual 3 kW modules DD3/R18 x 3/NS 18 x 5 kW 9 dual 5 kW modules DD3/R18 x 5/NS 9 x 5 kW single modules DD3/R9/NS (3 x 5 kW) + (3 x 10 kW) single modules DD3/R3/NS

    Non-protected power crate (empty) for 1P+N and 2P protected dimmers 18 x 3 kW 9 dual 3 kW modules DD3/R18 x 3/NB 18 x 5 kW 9 dual 5 kW modules DD3/R18 x 5/NB 9 x 5 kW single modules DD3/R9/NB (3 x 5 kW) + (3 x 10 kW) single modules DD3/R3/NB

    Note: Power crates with a mix of 3 kW and 5 kW modules upon request

    Blank panel for non-wired crate DD3/RACK 0

    Options4P main on-load isolator switch DD3/INP.SW

    Cabinet input protection by HRC fuses (100 kA) DD3/INP.FUSE

    RCD protection per dimmer - 30 mA - 6 kA For 3 kW dimmers DD3/RCD/3KW For 5 kW dimmers DD3/RCD/5KW For 10 kW dimmers DD3/RCD/10KW

    Residual current monitoring and alarm module DD3 / LEAK.ALARM(1 or 3 modules per cabinet) measures and transmits true r.m.s. value of residual(earth leakage) current, with non-latched or latched alarms.Can also be integrated into the main switching board for monitoring otherequipment and dimmers (MEMOPACK, EURORACK)

    Advanced Dimmer Network (ADN) NETBUS Remote Dimmer Controller NETBUS Dimmer Manager kit including NETPORT/XT converter and software for PC KIT/DIMSOFT/PC

  • 38Lighting Technologies

    Plug-in Digital Dimmer Modules

    ReferenceDescription

    Dimmer Modules with 400 S Rise Time2 x 3 kW dimmer module with 1P protection by fuse DD3/T2 x 3/F/S 1P+N protection by fuse DD3/T2 x 3/F/SN 2P protection by fuse DD3/T2 x 3/F/B 1P protection by MCB DD3/T2 x 3/M/S 1P+N protection by MCB DD3/T2 x 3/M/SN 2P protection by MCB DD3/T2 x 3/M/B

    1 x 5 kW dimmer module with 1P protection by fuse DD3/T1 x 5/F/S 1P+N protection by fuse DD3/T1 x 5/F/SN 2P protection by fuse DD3/T1 x 5/F/B 1P protection by MCB DD3/T1 x 5/M/S 1P+N protection by MCB DD3/T1 x 5/M/SN 2P protection by MCB DD3/T1 x 5/M/B

    2 x 5 kW dimmer module with 1P protection by fuse DD3/T2 x 5/F/S 1P+N protection by fuse DD3/T2 x 5/F/SN 1P protection by MCB DD3/T2 x 5/M/S 1P+N protection by MCB DD3/T2 x 5/M/SN

    1 x 10 kW dimmer module with 1P protection by fuse DD3/T1 x 10/F/S 1P+N protection by fuse DD3/T1 x 10/F/SN 2P protection by fuse DD3/T1 x 10/F/B 1P protection by MCB DD3/T1 x 10/M/S 2P protection by MCB DD3/T1 x 10/M/B

    Dimmer Modules with 200 s Rise Time2 x 3 kW dimmer module with 1P protection by fuse DD3/P2 x 3/F/S 1P+N protection by fuse DD3/P2 x 3/F/SN 2P protection by fuse DD3/P2 x 3/F/B 1P protection by MCB DD3/P2 x 3/M/S 1P+N protection by MCB DD3/P2 x 3/M/SN 2P protection by MCB DD3/P2 x 3/M/B

    1 x 5 kW dimmer module with 1P protection by fuse DD3/P1 x 5/F/S 1P+N protection by fuse DD3/P1 x 5/F0/SN 2P protection by fuse DD3/P1 x 5/F/B 1P protection by MCB DD3/P1 x 5/M/S 1P+N protection by MCB DD3/P1 x 5/M/SN 2P protection by MCB DD3/P1 x 5/M/B

    2 x 5 kW dimmer module with 1P protection by fuse DD3/P2 x 5/F/S 1P+N protection by fuse DD3/P2 x 5/F/SN 1P protection by MCB DD3/P2 x 5/M/S 1P+N protection by MCB DD3/P2 x 5/M/SN

    Notes: With 1P+N protection, N is cut but not protected. Modules with 800 s rise time upon request

  • ReferenceDescription

    39Lighting Technologies

    EURODIM 3

    200 s Dimmer Modules for Fluorescent Lamps1 x 3 kW dimmer + 1 direct output (same phase), with 1P protection by fuse DD3/FLUO/F/S 1P+N protection by fuse DD3/FLUO/F/SN 1P protection by MCB DD3/FLUO/M/S 1P+N protection by MCB DD3/FLUO/M/SN

    400 s Dimmer Module with By-Pass Switch1 x 5 kW dimmer + manually operated by-pass switch - Fuse 1P+N DD3/T1 x 5/BP/F/SN

    - MCB/1P DD3/T1 x 5/BP/M/S

    Note: closing the by-pass switch converts the dimmed output into a direct output

    Direct Feed-through (non-dim) Modules with noRemote Control2 x 3 kW dimmer module with 1P protection by fuse DD3/2 x 3/ND/F/S 1P+N protection by fuse DD3/2 x 3/ND/F/SN 1P protection by MCB DD3/2 x 3/ND/M/S 1P+N protection by MCB DD3/2 x 3/ND/M/SN

    1 x 5 kW dimmer module with 1P protection by fuse DD3/1 x 5/ND/F/S 1P+N protection by fuse DD3/1 x 5/ND/F/SN 1P protection by MCB DD3/1 x 5/ND/M/S 1P+N protection by MCB DD3/1 x 5/ND/M/SN

    Heavy Duty Contactor Modules2 x 3 kW dimmer module with 1P protection by fuse DD3/2 x 3/SW/F/S 1P+N protection by fuse DD3/2 x 3/SW/F/SN 1P protection by MCB DD3/2 x 3/SW/M/S 1P+N protection by MCB DD3/2 x 3/SW/M/SN

    1 x 5 kW dimmer module with 1P protection by fuse DD3/1 x 5/SW/F/S 1P+N protection by fuse DD3/1 x 5/SW/F/SN 1P protection by MCB DD3/1 x 5/SW/M/S 1P+N protection by MCB DD3/1 x 5/SW/M/SN

    Other Modules Dummy module for 3 or 5 kW slots DD3/TB Dummy module for 10 kW slots DD3/TB/10

    Note: Other module configurations upon request.

  • 40Lighting Technologies

    EUROSPOT300 / 500 W Spotlights

    F 51 18 - 65 Fresnelwith: 112 mm Fresnel lens GY 9.5 lampholder 1 m power supply cable (2 x 1.5 + 1.5 mm2) without plug 1 safety grid 1 metal filter frame

    Dimensions (A x B x C): 245 x 220 x 240 mmWeight : 2.2 kg

    DW 54 30 - 47 Zoom profile with condenserwith: 2 zoom lenses and 1 condenser lens GY 9.5 lampholder 4 beam shaping shutters with isolated handles 1 m power supply cable (2 x 1.5 + 1.5 mm2) without plug 1 safety grid 1 metal filter frame

    Dimensions (A x B x C): 370 x 220 x 260 mmWeight : 3.5 kg

    DS 54 18 - 38 Zoom profile with condenserwith: 2 zoom lenses and 1 condenser lens GY 9.5 lampholder 4 beam shaping shutters with isolated handles 1 m power supply cable (2 x 1.5 + 1.5 mm2) without plug 1 safety grid 1 metal filter frame

    Dimensions (A x B x C): 440 x 220 x 260 mmWeight : 3.7 kg

    C 51 9 - 60 Prism-convexwith : 112 mm prism convex lens GY 9.5 lampholder 1 m power supply cable (2 x 1.5 + 1.5 mm2) without plug 1 safety grid 1 metal filter frame

    Dimensions (A x B x C): 310 x 220 x 260 mmWeight : 2.7 kg

    DS 51 18 - 38 Zoom profilewith : 2 zoom lenses GY 9.5 lampholder 4 beam shaping shutters with isolated handles 1 m power supply cable (2 x 1.5 + 1.5 mm2) without plug 1 safety grid 1 metal filter frame

    Dimensions (A x B x C): 440 x 220 x 260 mmWeight : 3.7 kg

    AB

    C

    3D drawings available on AUTOCAD

  • ReferenceDescription

    41Lighting Technologies

    F 51 Fresnel spotlight F 51C 51 Prism-convex spotlight C 51DS 51 Zoom profile spotlight 18 - 38 DS 51DW 54 Zoom profile spotlight 30 - 47 DW 54DS 54 Zoom profile spotlight 18 - 38 DS 54

    Accessories

    Set of 4 cardboard filter frames PFC/EURO

    Metal filter frame PFM/EURO

    Rotatable 4-leaf barndoor for F51 and C51 CF/EURO

    Iris diaphragm for DS and DW profiles OR/EURO

    Gobo holder for DS and DW profiles SP/GO/EURO

    Hook clamp for 21 to 48 mm tubes A6

    Hook clamp for 35 to 50 mm tubes A20

    Hook clamp for 35 to 50 mm tubes A25

    Hook clamp for 45 to 60 mm tubes A30

    1.2 m spotlight safety cable CAS 120/N

    Lamps

    See page 79

    Spare Parts

    1 m cable (2 x 1.5 + 1.5 mm2) without plug C.EURO

    GY9.5 lampholder kit for C51 KIT/GY9,5/C5

    GY9.5 lampholder kit for F51 KIT/GY9,5/F5

    GY9.5 lampholder kit for EUROSPOT profiles KIT/GY9,5/D5

    112 Fresnel lens for F 51 F112

    112 Prism-convex lens for C 51 PC112/PEBBLE

    60 Condenser lens for DW 54 and DS 54 PYREX 60

    88.9zoom 1 PC lens for DW 54 and DS PC88/RC62

    or zoom 2 PC lens for DW 54

    100 zoom 1 PC lens for DS51 PC100/RC95

    or zoom 2 PC lens for DS 54

    Set of 4 beam shaping shutters for DS 51, DW 54 and DS 54 CM/EURO

    F51C51

    DS51 - DS54 - DW54

  • 42Lighting Technologies

    C

    B A

    A 57 F 14 - 59 Fresnel

    with: 120 mm Fresnel lens GY 9.5 lampholder 2 m power supply cable (2 x 1.5 + 1.5 mm2) without plug 1 safety grid 1 metal filter frame

    Dimensions (A x B x C): 290 x 225 x 330 mmWeight : 3.4 kg

    A 59 Z 16 - 35 Zoom Profile withCondenser Optics

    with: 2 zoom lenses and condenser optics GY 9.5 lampholder 4 beam shaping shutters with heat insulated handles 2 m power supply cable (2 x 1.5 + 1.5 mm2) without plug 1 metal filter frame

    Dimensions (A x B x C): 515 x 225 x 330 mmWeight : 5.8 kg

    A 56 C 9 - 66 Prism Convex

    with: 120 mm prism-convex lens GY 9.5 lampholder 2 m power supply cable (2 x 1.5 + 1.5 mm2) without plug 1 safety grid 1 metal filter frame

    Dimensions (A x B x C): 290 x 225 x 330 mmWeight : 3.5 kg

    "A" Range300 / 500 / 650 W Spotlights

    3D drawings available on AUTOCAD

  • ReferenceDescription

    43Lighting Technologies

    A 57 F Fresnel spotlight A 57 FA 56 C Prism convex spotlight A 56 CA 59 Z Zoom profile spotlight 16 - 35 A 59 Z

    Accessories

    Set of 4 cardboard filter frames PFC/A650

    Metal filter frame PFM/A650

    Rotatable 4-leaf barndoor for A 57 F CF/A650

    Iris diaphragm for A 59 Z OR/A650

    Double gobo holder for A 59 Z SP/A650

    Hook clamp for 21 to 48 mm tubes A6

    Hook clamp for 35 to 50 mm tubes A20

    Hook clamp for 35 to 50 mm tubes A25

    Hook clamp for 45 to 60 mm tubes A30

    1.2 m spotlight safety cable CAS 120/N

    Lamps

    See page 79

    Spare Parts

    2 m cable (2 x 1.5 + 1.5 mm2) without male plug C. EUROPE

    CEE 22 female receptacle CEE


Recommended