Page 1: Deterioration of CMP: Abrasion and Erosion caused by years of water and debris flowing through the pipe Deterioration of CMP: Abrasion and Erosion caused.
Page 2: Deterioration of CMP: Abrasion and Erosion caused by years of water and debris flowing through the pipe Deterioration of CMP: Abrasion and Erosion caused.

Do you have culverts that look like this?

Page 3: Deterioration of CMP: Abrasion and Erosion caused by years of water and debris flowing through the pipe Deterioration of CMP: Abrasion and Erosion caused.

•Deterioration of CMP:• Abrasion and Erosion

caused by years of water and debris flowing through the pipe

•Flow Line Corrosion Effects:• Structural deterioration

of ..flow line• Structural

backfill ..displaced• Side support is lost• Sink holes develop

at ..surface• Catastrophic failure

Page 4: Deterioration of CMP: Abrasion and Erosion caused by years of water and debris flowing through the pipe Deterioration of CMP: Abrasion and Erosion caused.

CMP Repair can rehab and stabilize your culverts to look

like this.

Page 5: Deterioration of CMP: Abrasion and Erosion caused by years of water and debris flowing through the pipe Deterioration of CMP: Abrasion and Erosion caused.

The CMP Repair Solution

Page 6: Deterioration of CMP: Abrasion and Erosion caused by years of water and debris flowing through the pipe Deterioration of CMP: Abrasion and Erosion caused.

An invert with a corroded bottom, causing loss of flow and soil stability.

Page 7: Deterioration of CMP: Abrasion and Erosion caused by years of water and debris flowing through the pipe Deterioration of CMP: Abrasion and Erosion caused.

We reline the invert with coated galvanized metal plates.

Page 8: Deterioration of CMP: Abrasion and Erosion caused by years of water and debris flowing through the pipe Deterioration of CMP: Abrasion and Erosion caused.

Overlapping the sheets of metal upstream.

Page 9: Deterioration of CMP: Abrasion and Erosion caused by years of water and debris flowing through the pipe Deterioration of CMP: Abrasion and Erosion caused.

*Filling voids created by

erosion……………. *Stabilizing soil *Bonds existing pipe …to new corrosion …free insert *Displaces water *Forces flow to return .. to host pipe.

High Density Poly-urethane is

Injected

Page 10: Deterioration of CMP: Abrasion and Erosion caused by years of water and debris flowing through the pipe Deterioration of CMP: Abrasion and Erosion caused.

Using a high pressured fastener tool to adhere the new lining to the host pipe.

Page 11: Deterioration of CMP: Abrasion and Erosion caused by years of water and debris flowing through the pipe Deterioration of CMP: Abrasion and Erosion caused.

At the

inlet and

outflow of

the pipe,

the ends

are cut

and bent

over the

invert to

seal and

protect

the

openings.

Page 12: Deterioration of CMP: Abrasion and Erosion caused by years of water and debris flowing through the pipe Deterioration of CMP: Abrasion and Erosion caused.

BEFORE AFTER

Harris County Flood Control Katy, TX

Page 13: Deterioration of CMP: Abrasion and Erosion caused by years of water and debris flowing through the pipe Deterioration of CMP: Abrasion and Erosion caused.

Before After

Lovell, WY

Page 14: Deterioration of CMP: Abrasion and Erosion caused by years of water and debris flowing through the pipe Deterioration of CMP: Abrasion and Erosion caused.

BNSF near Sapulpa, OK

BEFORE AFTER

Page 15: Deterioration of CMP: Abrasion and Erosion caused by years of water and debris flowing through the pipe Deterioration of CMP: Abrasion and Erosion caused.

BEFORE AFTER

BNSF Oklahoma

Page 16: Deterioration of CMP: Abrasion and Erosion caused by years of water and debris flowing through the pipe Deterioration of CMP: Abrasion and Erosion caused.

Union Pacific, Fayetteville TX

AfterBefore

Page 17: Deterioration of CMP: Abrasion and Erosion caused by years of water and debris flowing through the pipe Deterioration of CMP: Abrasion and Erosion caused.

Benefits to using CMP Repair

* Patented Process*Continually building working relationships ..with companies and cities such as BNSF, ..Union Pacific, City of Ft. Worth TX, Harris ..Co. Flood Control, W.T Byler, Rj Corman* Affiliated with URETEK USA*When working with railroad companies: No ..interruption to track time* When working for cities: No road closures ..or interruptions to traffic

Page 18: Deterioration of CMP: Abrasion and Erosion caused by years of water and debris flowing through the pipe Deterioration of CMP: Abrasion and Erosion caused.

We have built a removable skid with a complete operating system that can be

sent down the track

Page 19: Deterioration of CMP: Abrasion and Erosion caused by years of water and debris flowing through the pipe Deterioration of CMP: Abrasion and Erosion caused.

Off loading the skid in a remote location.

Page 20: Deterioration of CMP: Abrasion and Erosion caused by years of water and debris flowing through the pipe Deterioration of CMP: Abrasion and Erosion caused.

CMP Repair15525 Coe Loop

Magnolia, TX 77355(281)356-2084

www.cmprepair.com