Emitter Selection
Emitter typesLong path emitters,Short orifice emitters,Vortex emitters,Pressure compensating emitters,Porous pipe or tube emitters.
Further classificationPoint sourceLine source Sprays
Microsprinkler/SpraysOrifice control emitters Flow rate at any given pressure is governed primarily by the
orifice diameter Turbulent flow devices - flow rate is regulated by dissipating
energy. Flow velocities are greater and the potential for clogging is less
than for laminar flow devices. Flow rates are less sensitive to pressure (emitter exponent is
about 0.5) and less sensitive to water temperature than are laminar flow devices.
Vortex Control Emitters• Less sensitive to pressure variations than laminar or turbulent flow
emitters (emitter exponent is about 0.4). • Low pressure area formed in the center where the orifice is located
caused by vortex – reducing energy of water at the discharge point & a controlled flow rate.
• Emitter flow rate is controlled by vortex design and orifice diameter.Pressure Compensating Emitters
• Excess inlet pressure used to deform a diaphragm to control the flow rate.
• As the pressure increases, the diaphragm restricts the passage diameter.
• Pressure compensating emitters are designed to discharge at a fairly constant rate over a wide range of pressures (emitter exponent is normally less than 0.1).
• Drawbacks - the elasticity of the diaphragm may change over time.
• Diaphragms often retain some moisture when the pressure is off and bacteria growth ants seeking food source may result in clogging or destruction of diaphragm.
Stake Assemblies Stake assemblies raise emitter 8
inches above the ground. o larger wetting patterno water dispersed over weeds and grass.
4 mm ID tubing made of vinyl or polyethylene (PE).
Spaghetti tubing length depends on grower preference, but typically is 2 to 4 ft long
Wetting Patterns spinner
spray
• Important consideration in sandy soils or where root zones are shallow.
• Larger wetting patterns are often preferred for tree crops. o Emitters flow needs to correspond
with diameter to manage them effectively.
o When discharge is ≤0.08 in/hr, it requires very long run times to move the water into the mid and lower root zone.
o Potential for more wind drift, evaporation, and wetting of non-productive areas as the diameter increases.
• High density plantingso Most effective to provide each tree
with a smaller pattern emitter than to install larger pattern emitters on every other tree.
o Wetting pattern from larger diameter emitters is often distorted by interference from tree trunks and low branches
o However, small wetting patterns associated with low flow rates can lead to more plugging problems, particularly with the orifice control emitters.
Catch distribution patterns
(a) spinner
(b) spray
• Spinners have much higher application uniformities than the spray-type emitters.
• Both types have higher uniformity with high pressure 20 psi or higher compared 15 psi.
• Spinners - most of the wetted area receiving near-average application depths, with nearly continuous wetting throughout the pattern.
• Spray- wetted spokes radiating from the emitter with 50-75% of the area within the coverage diameter receiving little or no wetting.
• Lateral movement of water in the soil may help compensate for this in the root zone to varying degrees depending on the soil type
Class Activity
Emitter Selection Criteria1. Inexpensive2. Closeness of discharge-pressure
relationship to design specifications. 3. Easy to Install4. Susceptibility to clogging5. Pressure compensating 6. Not affected by temperature and
solar radiation7. Reliablity of discharge-pressure
relationship over a long period of time
Manufacturing variationThe variations in emitter passage
size, shape, and surface finish that do occur are small in absolute magnitude but represent a relatively large percent variation.
Emitter manufacturing variability
Coefficient of manufacturing variation (CV)is a statistical description of how uniformly the flow rate of each manufactured emitter is in relation to one another
meandeviation Standard
CV
Example
DRIP AND SPRAY EMITTERS CV’s CLASSIFICATION
CV < 0.05 Excellent
0.05 < CV < 0.07 Average
0.07 < CV < 0.11 Marginal
0.11 < CV < 0.15 poor
0.15 < CV unacceptable
LINE-SOURCE TUBING CV’s CLASSIFICATION
CV < 0.10 Good
0.10 < CV < 0.20 Average
0.20 < CV Poor to unacceptable
Flow rateFlow is characterized by the following equation
Where:q = flow rate (gph)P = pressure (psi)x = emitter exponetK = flow constant
xq KP
Emitter Exponentis important and critical to the
design, management and uniformity of the Micro system
The exponent (x) measures the flatness of the discharge-pressure curve.
Flow rate/pressure relationship for a laminar flow emitter (X=1.00)
Flow rate/pressure relationship for a turbulent flow emitter (X=0.50)
Flow rate/pressure relationship for a pressure compensated flow emitter (X=0.0)
PC emittersEven the best PC emitters only have a
certain range of pressures over which they provide good pressure compensation.
A PC emitter may retain its compensating abilities at very high pressures. But when pressures exceed 35 psi or so, emitters tend to pop off the hose, or hoses tend to pop out of their fittings
System EU for a PC emittersThe EU for a PC emitter is still
dependent on the manufacturing variation CV
They do not have a discharge exponent of exactly 0.0, even though that is what is claimed
How to get x and KK and x may be obtained from manufacture or
calculated
For sprinkler x is nearly always 0.5For pressure compensating x ~ 0.0
xPqK
PPqq
x
log
log
2
1
2
1
ExampleGiven: q1 = 1.5 gph, q2 = 2.0 gph,
P1 = 12 psi, P2 = 20 psi
Find: x and K
Solution
37.020
2 56.0
2012log
25.1log
56.0
xPqKx
Practice problem
Emitter Flow rate qa
( / / )
T = set time (hrs)
q
( / )
a
Where:
emitter flow rate (ave) number of emitters
F gallons per day per plant
a
g d plant
gp da
a
e
Fq
T e
Determine average emitter pressure head (Pa)
1x
aa
qPK
Where:
qa= average emitter flow rate (gph)Pa = average pressure (psi)x = emitter exponentK = flow constant
Average depth applied
Where:Fn = Average applied (in)e = number of emittersqa=average emitter flow rate (gph)Ta = set time (hrs)Sp = Plant spacing (ft)Sr = Row spacing (ft)
1.604 a an
p r
eq TF
S S
Determine total system flow rate
Where:A = field area, ac.e = number of emitters per plant.N = number of operating stations.qa = average or design emission rate, gph.Sp = plant spacing in the row, ft.Sr = distance between plant rows, ft
rp
as SS
qeNAQ 726