+ All Categories
Home > Documents > Final set of measurement for the irradiation quality assurance.

Final set of measurement for the irradiation quality assurance.

Date post: 31-Dec-2015
Category:
Upload: willoughby-roland
View: 32 times
Download: 0 times
Share this document with a friend
Description:
Final set of measurement for the irradiation quality assurance. What test do we need?. Not too extensive, to show difficult statistical fluctuactions. EFFICIENT. Sensitive to problems. Thorough to check all important parameters!. NON-AMBIGUOUS. - PowerPoint PPT Presentation
Popular Tags:
9
Workshop on CMS irradiati on sensor Qualification&A ssurance 1 Final set of measurement for the irradiation quality assurance. What test do we need? EFFICIEN T NON-AMBIGUOUS Sensitive to problems Not too extensive, to show difficult statistic fluctuactions Thorough to check all important parameters!
Transcript
Page 1: Final set of measurement for the irradiation quality assurance.

Workshop on CMS irradiation sensor Qualification&Assurance

1

Final set of measurement for the irradiation quality assurance.

What test do we need?

EFFICIENT

NON-AMBIGUOUS

Sensitive to problems

Not too extensive, to show difficult statistical fluctuactions

Thorough to check all important parameters!

Page 2: Final set of measurement for the irradiation quality assurance.

Thorough to check all important parameters! EFFICIENT

• All paramaters: V_dep, I_TOT, Strip Parameter

• But only on a subsample of strips

• All measurements in one measurement run (if possible)

• Strip measurement only on 2 DC pads!

10 20 30 40 50 60 705,00E-013

6,00E-013

7,00E-013

8,00E-013

9,00E-013

1,00E-012

normal measurement of Cint at DC-Pads with LCR at 1MHzAC-shorts between red strips

Inte

rstr

ip C

apac

itanc

e

strip number10 20 30 40 50 60 70

5,00E-013

6,00E-013

7,00E-013

8,00E-013

9,00E-013

1,00E-012normal measurement of Cint at AC-Pads with LCR at 1MHz

AC-shorts between red strips

Inte

rstr

ip C

apac

itanc

e

strip number

Page 3: Final set of measurement for the irradiation quality assurance.

Not too extensive, to show difficult statistical fluctuactions or setup problems

• Problems with bonding or residuals of conductive rubber OR... could interfere with the measurement one strange result, even explainable by feature of the setup could possibly dis-qualify a complete batch of sensors

• e.g. CC @ conductive rubber remains:

0 20 40 60 80 100 120 140

20

40

60

80

100

120

Coupling Capacitance on TS H39

Before After irrad. and annealing

Co

ulp

ling

Ca

pa

cita

nce

[pF

]

ONLY sample of 10 strips! = FAST

Page 4: Final set of measurement for the irradiation quality assurance.

Sensitive to problems RAMPSmore information of the strip paramter (here after irrad)

0 200 400 600 8001x106

2x106

3x106

4x106

5x106

6x106

7x106

Rpoly =U/INot corrected for leakage current

Rpoly

(O

hm

)

Voltage (V)

0 200 400 600 800

0,0

1,0x10-7

2,0x10-7

3,0x10-7

4,0x10-7

5,0x10-7

6,0x10-7

single strip leakage current

Leaka

ge c

urr

ent (A

)

Voltage (V)

0 200 400 600 800 10006,30E-013

6,32E-013

6,34E-013

6,36E-013

6,38E-013

6,40E-013

6,42E-013

6,44E-013

6,46E-013

6,48E-013

6,50E-013

Interstrip capacitanceOne neighbour

Cin

t (F

)

Voltage (V)

0 200 400 600 800 10001,00E-013

2,00E-013

3,00E-013

4,00E-013

5,00E-013

6,00E-013

7,00E-013

8,00E-013

9,00E-013

1,00E-012

1,10E-012

1,20E-012

1,30E-012

Before irrad (1MHz) Before irrad (100kHz) After irrad (1MHZ) After irrad (100kHZ)

Inte

rstr

ip C

ap

acita

nce

(F

)

Voltage (V)

Page 5: Final set of measurement for the irradiation quality assurance.

Sensitive to problems RAMPSinterstrip resistance

0 100 200 300 400 500 600

1E-5

1E-4

1E-3

0,01

1E7

1E8

1E9

Interstrip resistance C5 MSE C6

Rin

t (O

hm)

// M

SE

Voltage (V) 0 10

1E-5

1E-4

1E-3

0,01

1E7

1E8

1E9

Interstrip resistance C5 MSE C6

Rin

t (O

hm)

// M

SE

Voltage (V)

Ke ith le y 6517 A

Sp a nnung sq ue lle

Ele ktro m e te r

+ -

Se nso rrüc kse ite

HP 661 4C

+

-

Page 6: Final set of measurement for the irradiation quality assurance.

Calibration KA-LouvainIV & CV

-50 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 8500,00E+000

2,00E-010

4,00E-010

6,00E-010

8,00E-010

CV Karlsruhe CV Louvain

C_

TO

T (

F)

Voltage

0 100 200 300 400 500 6000,00E+000

2,00E-009

4,00E-009

6,00E-009

8,00E-009

1,00E-008

1,20E-008

1,40E-008

1,60E-008

1,80E-008

2,00E-008

IV Karlsruhe IV Louvain

To

tal l

ea

kag

e c

urr

en

t (A

)

Voltage (V)

KA: Offset due toAdd. 50pF (Iso-box)

Page 7: Final set of measurement for the irradiation quality assurance.

Strip parameter ST teststructure calibration KA-Louvain

0 20 40 60 80 100 120 140100000

1000000

1E7

1E8

1E9

1E10

1E11

1E12

Interstrip Resistance ST teststructure

Inte

rstr

ip R

esis

tan

ce

Stripnumber

0 20 40 60 80 100 120 140

2,0x105

4,0x105

6,0x105

8,0x105

1,0x106

1,2x106

1,4x106

1,6x106

1,8x106

2,0x106

Rpoly Karlsruhe Rpoly Louvain

Rp

oly

(O

hm

)

Stripnumber

20 40 60 80 100 1208,00E-011

1,00E-010

Coupling capacity k595 Karlsruhe Coupling capacity LCR Karlsruhe Coupling capacity LCR Louvain

Co

up

ling

ca

pa

city (

F)

stripdata

Interstrip capacitance: KA 0.64pF (1 neighbour)Louvain 1.05pF (2 neighbours)

0 20 40 60 80 100 120 1404,00E-011

6,00E-011

8,00E-011

1,00E-010

1,20E-010

1,40E-010

1,60E-010

1,80E-010

2,00E-010

2,20E-010

2,40E-010

2,60E-010

2,80E-010

3,00E-010

Leakage current

Le

aka

ge

cu

rre

nt (A

)

Stripnumber

Page 8: Final set of measurement for the irradiation quality assurance.

Future calibration

• Second calibration run

• Calibration with an irradiated teststructure

• Anealing curve as proposed by Alexander and and agreed with Louvain

Page 9: Final set of measurement for the irradiation quality assurance.

FINAL SET proposal (to freeze)• All measurements after 80 min @ 60°C and > 6h in the fridge• All measurements @-10°C• DIODE:

– IV, CV (1MHz with guard on GND)

I_TOT, V_dep, C_TOT, • Minisensor or full sensor

IV, CV on diode (1kHz)

Strip measurements: all on 2 DC pads• Rpoly, Cint, Rint, leakage current

» for 10 strips » With a voltage ramp 1V/s [1-30V] 10V/s [40-600V]

For the beginning: full check for pinholes


Recommended