+ All Categories

fm21

Date post: 01-Nov-2014
Category:
Upload: fatima-chelihi
View: 77 times
Download: 12 times
Share this document with a friend
2
FM21 SERIES AND PARALLEL PUMPS DEMONSTRATION UNIT Centrifugal pumps are often used together to enhance either the flow rate or the delivery pressure beyond that available from a single pump. The unit is designed to demonstrate the operational advantages of parallel or series operation, depending on the required duty. TECHNICAL DESCRIPTION This bench-top unit is self-contained and includes a reservoir and pipework for continuous water circulation. Ball valves at the pump inlets and outlets allow the configuration to be selected. A manually operated valve controls the flow, which is monitored by a single orifice plate. The two single-stage pumps are driven by close-coupled 180W ac induction motors. Maximum head (each pump) is 10mWG, and maximum flow (each pump) is 1 litre/s (at 50Hz). Measurement sensors are included in the supply. They monitor: pressure head across each of the pumps P across the orifice plates (hence flow-rate) water temperature at the inlet rotational speed of the impellers A CD-ROM with data logging educational software is included in the supply of this unit. Optional power measurement sensors are available, to measure the consumption of each pump. Note: If at least one power measurement sensor is ordered, all the practical exercise capabilities of the Single Centrifugal Pump Demonstration Unit FM20 can be performed.
Transcript
Page 1: fm21

FM21SERIES ANDPARALLEL PUMPSDEMONSTRATION UNITCentrifugal pumps are often usedtogether to enhance either theflow rate or the deliverypressure beyond that availablefrom a single pump.

The unit is designed todemonstrate the operationaladvantages of parallel or seriesoperation, depending on therequired duty.

TECHNICAL DESCRIPTIONThis bench-top unit is self-contained and includes areservoir and pipework for continuous water circulation.Ball valves at the pump inlets and outlets allow theconfiguration to be selected. A manually operated valvecontrols the flow, which is monitored by a single orificeplate.The two single-stage pumps are driven by close-coupled180W ac induction motors. Maximum head (each pump)is 10mWG, and maximum flow (each pump) is 1 litre/s(at 50Hz).Measurement sensors are included in the supply.They monitor:➤ pressure head across each of the pumps

➤ ∆ P across the orifice plates (hence flow-rate)

➤ water temperature at the inlet

➤ rotational speed of the impellers

A CD-ROM with data logging educational software isincluded in the supply of this unit.Optional power measurement sensors are available, tomeasure the consumption of each pump.Note: If at least one power measurement sensor isordered, all the practical exercise capabilities of theSingle Centrifugal Pump Demonstration Unit FM20 can beperformed.

Page 2: fm21

INSTRUCTIONAL CAPABILITIES➤ Demonstration of either series, parallel or single

pump operation➤ Comparison of head-flow characteristics with

single pump operation, at inherent speed➤ Comparative measurement of power and overall

efficiency at different speeds (with 2 SWA1)➤ Comparison of student calculations with

computer results

ORDERING SPECIFICATION• A small-scale series/parallel pump

demonstration unit.• Equipped with electronic measurement

sensors for pump differential pressure, orifice differential pressure (flow-rate), temperature and rotational speed.

• Capable of being linked to a PC (not supplied) via the IFD6 interface console (available as an essential accessory).

• Powered via the SWA1 power measurement unit (available as an essential accessory).

• Self-contained, bench-top machine.• Supplied with software providing full

instructions for setting up, operating, calibrating and performing the teaching exercises. Facilities are provided for logging, processing and displaying data graphically. Full theoretical back-up is included together with a student questions and answers session.

ESSENTIAL ARMFIELD ACCESSORIESIFD6 Interface Device (page 35)Two SWA1 Integrating Wattmeters (page 35)

ORDERING INFORMATIONFM21-50 for 50Hz mains supplyFM21-60 for 60Hz mains supply(Note: Voltage compensation takes place in theIFD6, see page 35).

OVERALL DIMENSIONSHeight: 780mmLength: 850mmWidth: 450mm

SHIPPING SPECIFICATIONSGross Weight: 50KgVolume: 0.50m3


Recommended