+ All Categories
Home > Documents > Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD)...

Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD)...

Date post: 02-Jul-2018
Category:
Upload: lynga
View: 234 times
Download: 0 times
Share this document with a friend
26
Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) Version 4.7A November 2005 Release Notice Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved
Transcript
Page 1: Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) …manuals.ts.fujitsu.com/file/6634/sysfgm.spool.047.e.pdf · The Release Notice is supplied as a text file. ... SYSSSI.SPOOLSYS.022

Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) Version 4.7A November 2005 Release Notice Copyright (C) Fujitsu Siemens Computers GmbH 2005 All rights reserved

Page 2: Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) …manuals.ts.fujitsu.com/file/6634/sysfgm.spool.047.e.pdf · The Release Notice is supplied as a text file. ... SYSSSI.SPOOLSYS.022

1

Release Notice SPOOL V4.7A 1 General 2 1.1 Ordering 2 1.2 Delivery 2 1.3 Documentation 7

2 Software extensions 9 3 Technical information 9 3.1 Resource requirements 9 3.2 Software configuration 11 3.3 Product installation 13 3.4 Product use 21 3.5 Discontinued functions 22 3.6 Incompatibilities 22 3.7 Restrictions 22 3.8 Procedure in the event of errors 22

4 Hardware support 24

Page 3: Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) …manuals.ts.fujitsu.com/file/6634/sysfgm.spool.047.e.pdf · The Release Notice is supplied as a text file. ... SYSSSI.SPOOLSYS.022

2

1 General This Release Notice contains outline descriptions of the major expansions, interdependencies and application notes pertaining to SPOOL V4.7, SPOOLSYS V2.2, SPSERVE V2.8, SPSRVMAN V2.3, PRMMAN V1.3 and PRMPRES V1.2 under the ope- *1 rating system BS2000/OSD-BC >= V5.0 and OSD/XC >= V1.0 *).

The contents corresponds to release status : November 2005.

The Release Notice is supplied as a text file. The typogra- phical conventions for uppercase and lowercase are observed in the file. Updated versions of the file will be supplied as and when modifications to the product are registered.

This release notice is, like all other release notices con- cerning BS2000 products, available on the Internet under the URL

http://serviceportal.sbs.de/technics/technics/fgm_en/

fgm_index_en.htm

The command for printing this file (English version) is

/PRINT-DOCUMENT SYSFGM.SPOOL.047.E, - / DOCUMENT-FORMAT=*TEXT(LINE-SPACING=*BY-EBCDIC-CONTROL)

or

/PRINT-FILE SYSFGM.SPOOL.047.E,CONTROL-CHARACTER=EBCDIC

If the use of this product version means that one or more predecessor versions are skipped, the notes in the Release Notices (or README files) of the predecessor version or versions must also be taken into account.

1.1 Ordering

SPOOL V4.7, SPSERVE V2.8, SPSRVMAN V2.3, PRM V1.3, SPOOLSYS V2.2 are available through your local sales organization.

The general conditions of the Contract for the Use and Maintenance of Software Products apply for SPOOL V4.7, SPSERVE V2.8, SPSRVMAN V2.3, PRM V1.3 and SPOOLSYS V2.2.

1.2 Delivery

The files for SPOOL V4.7, SPOOLSYS V2.2, SPSERVE V2.8, SPSRVMAN V2.3, PRMMAN V1.3, and PRMPRES V1.2 are delivered through the SOLIS system.

*) BS2000/OSD (R) is a registered trademark of Fujitsu Sie- mens Computers Ltd.

Page 4: Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) …manuals.ts.fujitsu.com/file/6634/sysfgm.spool.047.e.pdf · The Release Notice is supplied as a text file. ... SYSSSI.SPOOLSYS.022

3

The valid file and volume attributes are listed in the SO- LIS2 delivery statement.

The distribution information is presented per subsystem.

1. SPOOL

The following release items are needed independent of the HSI:

Release Item Description ---------------------------------------------------

SIPLIB.SPOOL.047 Restricted macro libra-

ry

SYSFGM.SPOOL.047.D "Release notice" (Ger- man)

SYSFGM.SPOOL.047.E "Release notice" (En-

glish)

SYSLIB.SPOOL.047 User macro library

SYSMES.SPOOL.047 Complete message file

SYSSDF.SPOOL.047 SPOOL syntax file

SYSSSC.SPOOL.047 SSCM catalog declara- tion for SPOOL subsy- stem

SYSNRF.SPOOL.047 NO-reference symbol fi-

le

SYSPRC.SPOOL.047.NOTIF Spool registration pro- cedure for Notification Service

SYSRMS.SPOOL.047 RMS delivery set

SYSSII.SPOOL.047 IMON installation in-

formation

SYSSSI.SPOOL.047 SPOOL subsystem infor- mation file

SYSLIB SPOOL.047.BARC template library for

barcodes support (con- tent is HSI dependent)

The following release items are only needed on /390 hardware:

Release Item Description ---------------------------------------------------

SYSLNK.SPOOL.047 Load module library

SYSOML.SPOOL.047 Runtime for SPL API

Page 5: Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) …manuals.ts.fujitsu.com/file/6634/sysfgm.spool.047.e.pdf · The Release Notice is supplied as a text file. ... SYSSSI.SPOOLSYS.022

4

The following release items are only needed on SPARC64 hardware (SX product line):

Release Item Description ---------------------------------------------------

SPMLNK.SPOOL.047 Load module library

2. SPOOLSYS

Delivery includes the following files, from BS2000/OSD-BC V5.0 and OSD/XC >= V1.0:

The following release items are needed independent of the HSI:

Release Item Description ---------------------------------------------------

SIPLIB.SPOOLSYS.022 Restricted macro libra-

ry

SYSMES.SPOOLSYS.022 Complete message file

SYSRMS.SPOOLSYS.022 RMS delivery set

SYSSII.SPOOLSYS.022 IMON installation in- formation

SYSSSC.SPOOLSYS.022 SSCM catalog declara-

tion for SPOOLSYS sub- system

SYSSSI.SPOOLSYS.022 SPOOLSYS parameter file

SYSSDF.SPOOLSYS.022 SPOOLSYS syntax file

The following release items are only needed on /390 hardware:

Release Item Description ---------------------------------------------------

SYSLNK.SPOOLSYS.022 Load module library

The following release items are only needed on SPARC64 hardware (SX product line):

Release Item Description ---------------------------------------------------

SPMLNK.SPOOLSYS.022 Load module library

3. SPSERVE

The following release items are needed independent of the HSI:

Release Item Description ---------------------------------------------------

Page 6: Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) …manuals.ts.fujitsu.com/file/6634/sysfgm.spool.047.e.pdf · The Release Notice is supplied as a text file. ... SYSSSI.SPOOLSYS.022

5

SIPLIB.SPSERVE.028 Restricted macro libra-

ry

SPSERVE SPSERVE phase

SYSLIB.SPSERVE.028 User macro library

SYSLNK.SPSERVE.028 Load module library

SYSMES.SPSERVE.028 Complete message file

SYSRMS.SPSERVE.028 RMS delivery set

SYSSDF.SPSERVE.028 Syntax file

SYSSII.SPSERVE.028 IMON installation in- formation

4. SPSRVMAN

The following release items are needed independent of the HSI:

Release Item Description ---------------------------------------------------

SYSMES.SPSRVMAN.023 Complete message file

SYSSII.SPSRVMAN.023 IMON installation

SYSRMS.SPSRVMAN.023 RMS delivery set infor-

mation

SYSSSC.SPSRVMAN.023.130 SSCM catalog declara- tion

The following release items are only needed on /390 hardware:

Release Item Description ---------------------------------------------------

SYSLNK.SPSRVMAN.023 Load module library

The following release items are only needed on SPARC64 hardware (SX product line):

Release Item Description ---------------------------------------------------

SPMLNK.SPSRVMAN.023 Load module library

5. PRM

PRM V1.3 is composed of 2 parts :

(1) - a TPR subsystem PRMMAN V1.3 which manages

all resources collected in container.

(2) - a TU subsystem PRMPRES V1.2 which provides a

Page 7: Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) …manuals.ts.fujitsu.com/file/6634/sysfgm.spool.047.e.pdf · The Release Notice is supplied as a text file. ... SYSSSI.SPOOLSYS.022

6

command language and screen interface and is thus the visible part of the product.

PRMMAN

Delivery includes the following files :

The following release items are needed independent of the HSI:

Release Item Description ---------------------------------------------------

SYSMES.PRMMAN.013 Complete message file

SYSPRT.PRMMAN.013 Standard print resour-

ces library

SYSRMS.PRMMAN.013 RMS delivery set

SYSSII.PRMMAN.013 IMON installation in- formation

SYSSSC.PRMMAN.012.130 SSCM catalog declara-

tion

The following release items are only needed on /390 hardware:

Release Item Description ---------------------------------------------------

SYSLNK.PRMMAN.013 Load module library

The following release items are only needed on SPARC64 hardware (SX product line):

Release Item Description ---------------------------------------------------

SPMLNK.PRMMAN.013 Load module library

PRMPRES

The following release items are needed independent of the HSI:

Release Item Description ---------------------------------------------------

SYSFHS.PRMPRES.012 Screen library for al-

phascreen interface

SYSLNK.PRMPRES.012 Load module library

SYSMES.PRMPRES.012 Complete message file

SYSPRC.PRMPRES.012.LP-EMUL Procedure to add stan- dard preform objects

Page 8: Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) …manuals.ts.fujitsu.com/file/6634/sysfgm.spool.047.e.pdf · The Release Notice is supplied as a text file. ... SYSSSI.SPOOLSYS.022

7

SYSPRC.PRMPRES.012.EURO Procedure to add a EURO

glyph into a HP font object

SYSRMS.PRMPRES.012 RMS delivery set

SYSSDF.PRMPRES.012 Syntax file

SYSSII.PRMPRES.012 IMON installation in-

formation

SYSSSC.PRMPRES.012.120 SSCM catalogdeclaration

SYSPRC.PRMPRES.012.MIGRATE Procedure to migrate totally/partially HP resources from a PRFILE into PCL equivalent ones.

SYSPRG.PRMPRES.012.MIGRATE Executable for the mi-

gration of HP resources into PCL equivalent.

SYSSDF.PRMPRES.012.MIGRATE Syntax file associated

to the MIGRATE-PRINT- RESOURCES command.

SYSPRC.PRMPRES.012.EXTRACT Procedure to extract HP

& PCL resources from a PRFILE for refinement purposes on Windows.

SYSPRG.PRMPRES.012.EXTRACT Executable for the ex-

traction of HP & PCL resources.

SYSSDF.PRMPRES.012.EXTRACT Syntax file associated

to the EXTRACT-PRINT- RESOURCES command.

SPCDAT.PRMPRES.012.EXTRACT A self extractable com-

pressed file containing Windows programs for image conversion (BMP files to PCL macroes and PCL macroes to BMP files).

1.3 Documentation

The following documents are part of the scope of SPOOL V4.7.

Page 9: Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) …manuals.ts.fujitsu.com/file/6634/sysfgm.spool.047.e.pdf · The Release Notice is supplied as a text file. ... SYSSSI.SPOOLSYS.022

8

+----------------------------------+----------------------+ ! Title ! Order no. ! +----------------------------------+----------------------+ ! SPOOL V4.6(BS2000/OSD) German ! U3995-J-Z125-11 ! +----------------------------------+----------------------+ ! SPOOL V4.6(BS2000/OSD) English ! U3995-J-Z125-11-76 ! +----------------------------------+----------------------+ ! Spool & Print Kommandos German ! U25561-J-Z125-5 ! +----------------------------------+----------------------+ ! Spool & Print Commands English ! U25561-J-Z125-5-76 ! +----------------------------------+----------------------+ ! Spool & Print Makros German ! U41003-J-Z125-3 ! +----------------------------------+----------------------+ ! Spool & Print Macros English ! U41003-J-Z125-3-76 ! +----------------------------------+----------------------+ ! Spool & Print Meldungen German ! U22041-J-Z125-5 ! +----------------------------------+----------------------+ ! Spool & Print Messages English ! U22041-J-Z125-5-76 ! +----------------------------------+----------------------+ ! SPCONV V1.0 (BS2000/OSD) German ! U25563-J-Z125-1 ! +----------------------------------+----------------------+ ! SPCONV V1.0 (BS2000/OSD) English ! U25563-J-Z125-1-76 ! +----------------------------------+----------------------+ ! SPSERVE V2.6(BS2000/OSD) German ! U5011-J-Z125-13 ! +----------------------------------+----------------------+ ! SPSERVE V2.6(BS2000/OSD) English ! U5011-J-Z125-13-76 ! +----------------------------------+----------------------+ ! PRM V1.2 (BS2000/OSD) German ! U23163-J-Z125-3 ! +----------------------------------+----------------------+ ! PRM V1.2 (BS2000/OSD) English ! U23163-J-Z125-3-76 ! +----------------------------------+----------------------+

The documentation of the BS2000 standard configuration is also necessary for the use of SPOOL, SPSERVE, SPSRVMAN, SPOOLSYS, PRMMAN, PRMPRES. The appropriate hardware docu- mentation is required for use of the hardware peripherals. These manuals may be supplemented by README files. These files contain changes and additions to the product manual.

The names of these files are structured as follows: - SYSRME.SPOOL.047.E - SYSRME.SPOOL.047.D - SYSRME.SPSERVE.028.E - SYSRME.SPSERVE.028.D - SYSRME.SPCONV.011.E - SYSRME.SPCONV.011.D - SYSRME.PRMPRES.012.E - SYSRME.PRMPRES.012.D - SYSRME.SPOOLSYS.022.E - SYSRME.SPOOLSYS.022.D

For SPOOL&Print Explorer documentation, please refer to the SPOOL manual and/or to the SPOOL and Print readme file that is automatically installed in "Program Files/SPOOL and Print Explorer" PC's directory.

The documentation on current BS2000/OSD software products is also available under the following Internet address:

http://manuals.fujitsu-siemens.com/mainframes.html

Page 10: Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) …manuals.ts.fujitsu.com/file/6634/sysfgm.spool.047.e.pdf · The Release Notice is supplied as a text file. ... SYSSSI.SPOOLSYS.022

9

2 Software extensions 1. SPOOL

Only the expansions and improvements distinguishing this version from the predecessor version SPOOL V4.6 are described below: *1

*1 (1) Support of the new AFP-Router and HP2AFP. *1

*1 This new version of SPOOL allows the use of *1 the Router V2.0 and HP2AFP V2.0 (Oce - SPS *1 products). The old versions of those products *1 can still be used with SPOOL 4.7. *1

(2) SPSERVE

None

(3) PRM

None

(4) SPOOLSYS None

3 Technical information 3.1 Resource requirements

1. Virtual Address Space

(1) SPOOL

- 3,6 Mbyte Class 4 for subsystem loading (390), 6,0 Mbyte Class 4 for subsystem loading (SPARC64)

- Class 4 tables depending on number of wai- ting print-jobs, number of started printers, ...

(2) SPOOLSYS

- 250 Kbyte Class 4 for subsystem loading

(3) SPSERVE

- 1 Mbyte Class 6 for program loading

(4) SPSRVMAN

- 44 Kbyte Class 4 for subsystem loading

(5) PRM

- 600 Kbyte Class 4 for subsystem PRMMAN loa- ding

Page 11: Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) …manuals.ts.fujitsu.com/file/6634/sysfgm.spool.047.e.pdf · The Release Notice is supplied as a text file. ... SYSSSI.SPOOLSYS.022

10

- 1.6 Mbyte Class 4 for subsystem PRMPRES loa- ding

When using PRM via the FHS interface, an amount of 2 Mbyte class 6 is requested. This is needed to handle the print resource objects list onto the Desktop.

2. Static Disc Space

(1) SPOOL

- 13500 PamPages for the Release Items

- 2 PamPages per print job for EQUISAMQ file

(2) SPOOLSYS

- 720 PamPages for Release Items

(3) SPSERVE

- 1970 PamPages for Release Items

(4) SPSRVMAN

- 110 PamPages for Release Items

(5) PRM

- 2810 PamPages for PRMMAN Release Items

- 1110 PamPages for PRMPRES Release Items

3. Dynamic Disc Space

(1) SPOOL

- $SYSSPOOL.SPOOL.PARAMETERS : 600 PamPages as basic size, additional size depending on num- ber of defined SPSERVE objects (printers, forms, character-sets, ...)

- $SYSSPOOL.SPOOL.PARAMETERS.COPY : idem $SYS- SPOOL.SPOOL.PARAMETERS

- $TSOS.EQUISAMQ : size depending on the maxi- mum number of waiting print-jobs ever reached (more or less 1.5 to 2 PamPages per print-job)

(2) SPOOLSYS

- Not relevant

(3) SPSERVE

- Not relevant

(4) SPSRVMAN

Page 12: Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) …manuals.ts.fujitsu.com/file/6634/sysfgm.spool.047.e.pdf · The Release Notice is supplied as a text file. ... SYSSSI.SPOOLSYS.022

11

- Not relevant

(5) PRM

- The size of the PRFILE can considerably grow up when migrating HP resources into its PCL counterparts. Indeed, the conversion of forms overlay buffers can generate huge PCL macroes.

4. Special Hardware/Firmware/Processor/Real Memory

(1) SPOOL

SPOOL V4.7 also runs on SPARC64 machines.

(2) SPOOLSYS

SPOOLSYS V2.2 runs as well on /390 machines as on SPARC64 machines.

(3) SPSERVE

- Not applicable

(4) SPSRVMAN

SPSRVMAN V2.3 also runs on SPARC64 machines.

(5) PRM

PRMMAN V1.3 also runs on SPARC64 machines.

PRMPRES V1.2: not applicable

3.2 Software configuration

1. SPOOL

(1) Necessary environment From BS2000/OSD-BC V5.0 From OSD/XC >= V1.0

(2) Other necessary product(s)

If you use RSO you may use RSO from V3.1. (Recommended RSO V3.4A)

If you use DPRINT you need Dprint V1.0J or higher.

If you use SPS you need SPS V3.8A or higher.

If you use IDOM you need IDOM V01.2A or hig- her. (Recommended IDOM V01.3A)

(3) For special functions, necessary product(s)

If you use the SPOOL and Print Explorer V2.0A, you need: on the PC side:

Page 13: Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) …manuals.ts.fujitsu.com/file/6634/sysfgm.spool.047.e.pdf · The Release Notice is supplied as a text file. ... SYSSSI.SPOOLSYS.022

12

DESK2000 >= V04.0

on the BS2000 side: RSO from V3.4A (optional but requested for re- mote objects management) DPRINT from V1.0J(optional but requested for distributed objects management)

The spoolout on RSO IPP printers via URL ad- dressing is only available with RSO V03.4A.

4-bytes tape mnemonics are only available from BS2000/OSD-BC V6.0 and OSD/XC V2.0 .

2. SPOOLSYS

(1) Necessary environment

From BS2000/OSD-BC V5.0. From OSD/XC >= V1.0

(2) Other necessary product(s)

None

(3) For special functions, necessary product(s)

None.

3. SPSERVE

(1) Necessary environment

From BS2000/OSD-BC V5.0. From OSD/XC V1.0

(2) Other necessary product(s)

None

(3) For special functions, necessary product(s)

None.

4. SPSRVMAN

(1) Necessary environment

From BS2000/OSD-BC V5.0. From OSD/XC V1.0A

(2) Other necessary product(s)

None.

(3) For special functions, necessary product(s)

None.

5. PRM

Page 14: Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) …manuals.ts.fujitsu.com/file/6634/sysfgm.spool.047.e.pdf · The Release Notice is supplied as a text file. ... SYSSSI.SPOOLSYS.022

13

(1) Necessary environment

From BS2000/OSD-BC V5.0. From OSD/XC V1.0A

(2) Other necessary product(s)

For PRMPRES FHS-interface, VTSU V11.0 or greater is a prerequisite. The message file of VTSU must be activated before using PRM via the FHS interface. If OMNIS is used, it is ne- cessary to install OMNIS V6.3 (or up) and pay attention that VTSU V11.0 must be installed (message file activated before OMNIS is start- ed) also on the system where OMNIS is running.

(3) For special functions, necessary product(s)

Supported Oce tools : OFM as of V2.02, FGL as of V3.02

3.3 Product installation

In all versions (from BS2000/OSD-BC V5.0,OSD/XC V1.0) in- stallation of the product with the installation monitor IMON is mandatory, as the execution of the product requires a consistent Software Configuration Inventory (SCI).

The information concerning installation in the delivery co- ver letter and in the product documentation must be follo- wed as well as the information given below.

1. PRM

(1) Before IMON installation

Before IMON is started, the following actions have to be performed:

Name of the product files: PRM V1.3 is compli- ant to the IMON installation conventions.

Exchange of product: Only after stopping the preceding version.

Coexistence with other version of the product: Impossible.

Necessary privileges: Update of the standard print resources library (PRFILE) is only allo- wed for users with PRINT-SERVICE-ADMINISTRA- TION privilege.

The following files must be installed on the system:

A. The LLMs and Repfiles :

for PRMMAN:

Page 15: Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) …manuals.ts.fujitsu.com/file/6634/sysfgm.spool.047.e.pdf · The Release Notice is supplied as a text file. ... SYSSSI.SPOOLSYS.022

14

SYSLNK.PRMMAN.013 (390 platform),

SPMLNK.PRMMAN.013 (SPARC64 platform),

SYSREP.PRMMAN.013 (from SYSRMS.PRMMAN.013)

for PRMPRES:

SYSLNK.PRMPRES.012, SYSREP.PRMPRES.012 (from SYSRMS.PRMPRES.012)

B. The SSCM catalog files :

for PRMMAN :

SYSSSC.PRMMAN.013.130

for PRMPRES :

SYSSSC.PRMPRES.012.120

C. User interface files :

for PRMPRES only :

SYSSDF.PRMPRES.012. This syntax file must be attached as a sub-system syntax file with the command /MODIFY-SDF-PARAMETERS.

SYSFHS.PRMPRES.012 This screens library must be imperatively INSTALLED with the share attribute set to yes. (Default use- rid : SYSSPOOL)

D. Message files :

for PRMMAN :

SYSMES.PRMMAN.013

for PRMPRES :

SYSMES.PRMPRES.012

E. the IMON installation file : SYS-

SII.PRMMAN.013 (for PRMMAN), SYS- SII.PRMPRES.012 (for PRMPRES)

F. The system SSCM catalog has to be modi-

fied in order to include the PRMMAN and PRMPRES subsystem declarations.

G. The syntax file has to be merged in the

syntax file of the system.

H. The message files have to be activated.

(2) IMON installation

Page 16: Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) …manuals.ts.fujitsu.com/file/6634/sysfgm.spool.047.e.pdf · The Release Notice is supplied as a text file. ... SYSSSI.SPOOLSYS.022

15

After these actions have been executed, the product has to be installed with IMON. The ne- cessary inputs and the sequence of the instal- lation are described in the IMON documenta- tion.

Library of standard print resources :

The standard print resources library (PRFILE) must be installed and named according to IMON parameters. Make it share (/MODIFY-FILE-ATTRI- BUTES <prfile>,USER-ACCESS=*ALL-USERS). If this file is to be protected, catalogue it with a WRITE PASSWORD but ACCESS=WRITE in or- der to achieve time stamp update as well as to avoid start-stop, when printing out occurs. This PRFILE can be a copy of the delivered li- brary of standard print resources (SYSPRT.PRMMAN.013), a copy from the previous installation, or can be issued from the migra- tion of the HPFILE and SPOOLFILE.

(3) After IMON installation, the subsystems PRMMAN

and PRMPRES can be activated by issuing the START-SUBS PRMMAN (resp. PRMPRES) or PRMMAN can be automatically started at SPOOL activa- tion, or PRMPRES activation.

2. PRM Add-on functions

(1) Before IMON installation

Before IMON is started, the following actions have to be performed:

The following files must be installed on the system : SYSPRG.PRMPRES.012.MIGRATE, SYSPRG.PRMPRES.012.EXTRACT

(2) IMON installation

After these actions have been executed, the product has to be installed with IMON. The ne- cessary inputs and the sequence of the instal- lation are described in the IMON documenta- tion.

(3) After IMON installation

After successful installation, the following actions have to be performed:

for the Migration function: (SYSSDF.PRMPRES.012.MIGRATE) This syntax file must be activated as a subsy- stem syntax file with the command /MODIFY-SDF-PARAMETERS with subsystem pattern as PRMMIG. It provides the MIGRATE-PRINT-RE- SOURCES command that is implemented by the SYSPRC.PRMPRES.012.MIGRATE procedure file.

Page 17: Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) …manuals.ts.fujitsu.com/file/6634/sysfgm.spool.047.e.pdf · The Release Notice is supplied as a text file. ... SYSSSI.SPOOLSYS.022

16

for the Extraction function: (SYSSDF.PRMPRES.012.EXTRACT) This syntax file must be activated as a subsy- stem syntax file with the command /MODIFY-SDF-PARAMETERS with subsystem pattern as PRMEXT. It provides the EXTRACT-PRINT-RE- SOURCES command that is implemented using the procedure file SYSPRC.PRMPRES.012.EXTRACT.

Windows Utility (SPCDAT.PRMPRES.012.EXTRACT) This file must be transferred in binary on a Windows environment using FT-PCD. It must be renamed into a file with a .EXE extension. Run the .EXE file to extract the Windows applica- tion and DLL. As this utility has no setup program, it is recommended to create a dedica- ted directory where the extraction could oc- cur. This program is a 16-bit Windows applica- tion

3. SPOOLSYS

(1) Before IMON installation

Before IMON is started, the following actions have to be performed:

Name of the product files: SPOOLSYS V2.2 are compliant with the IMON installation conven- tions.

Exchange of product: Supported at DSSM level.

Coexistence with other version of the product: Impossible.

Necessary privileges: Use of the /MOVE-PRINT- JOBS command is only allowed for users with PRINT-SERVICES-ADMINISTRATION privilege.

The following files must be installed on the system:

A. the OML and REP-file :

SYSLNK.SPOOLSYS.022 (for 390 platform), SPMLNK.SPOOLSYS.022 (for SPARC64 plat- form), SYSREP.SPOOLSYS.022 (from SYSRMS.SPOOLSYS.022)

B. the SSCM catalog file :

As SPOOLSYS is loaded as a subsystem via DSSM, the DSSM catalog must be first up- dated with the product SSCM, using the catalog definition file: SYSSSC.SPOOL- SYS.022

C. the parameter file : SYSSSI.SPOOLSYS.022

Page 18: Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) …manuals.ts.fujitsu.com/file/6634/sysfgm.spool.047.e.pdf · The Release Notice is supplied as a text file. ... SYSSSI.SPOOLSYS.022

17

D. the message file : SYSMES.SPOOLSYS.022

E. the syntax file : SYSSDF.SPOOLSYS.022

F. the IMON installation file : SYS-

SII.SPOOLSYS.022

G. the system SSCM catalog has to be modi- fied in order to include the SPOOLSYS subsystem declarations. If several ver- sions have to be defined in the same ca- talog, the creation-date value of the ol- der ones has to be changed (for example into '*at-creation-request').

H. the message file and syntax files have to

be activated.

(2) IMON installation

After these actions have been executed, the product has to be installed with IMON. The ne- cessary inputs and the sequence of the instal- lation are described in the IMON documenta- tion.

(3) After IMON installation, the following actions

have to be performed:

SPOOLSYS is automatically started during the System Startup or by issuing the /START-SU SPOOLSYS,VERSION=... ,VERSION-PARALL=*EXCHANGE

4. SPOOL

(1) Before IMON installation

Before IMON is started, the following actions have to be performed:

Name of the product files: SPOOL V4.7 is com- pliant to the IMON installation conventions.

Exchange of product: Only after stopping the preceding version.

Coexistence with other version of the product: Impossible.

Necessary privileges: Spool & Print admini- stration functions are only allowed for the users with PRINT-SERVICE-ADMINISTRATION privi- lege.

The following files must be installed on the system:

A. the OML, NOREF-file and REP-file :

SYSLNK.SPOOL.047,(390 platform), SPMLNK.SPOOL.047,(for SPARC64 platform),

Page 19: Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) …manuals.ts.fujitsu.com/file/6634/sysfgm.spool.047.e.pdf · The Release Notice is supplied as a text file. ... SYSSSI.SPOOLSYS.022

18

SYSNRF.SPOOL.047, and SYSREP.SPOOL.047 (from SYSRMS.SPOOL.047)

B. the SSCM catalog file : SYSSSC.SPOOL.047

C. the syntax file : SYSSDF.SPOOL.047

D. the message file : SYSMES.SPOOL.047

E. the notification registration procedure :

SYSPRC.SPOOL.047.NOTIF

F. the IMON installation file : SYS- SII.SPOOL.047

G. the system SSCM catalog has to be modi-

fied in order to include the SPOOL subsy- stem declarations,

H. the syntax file has to be merged in the

syntax file of the system. Use BS2000 command /MODIFY-SDF-PARAMETER to activate dynamically the syntax file).

I. the message file has to be activated.

(2) IMON installation

After these actions have been executed, the product has to be installed with IMON. The ne- cessary inputs and the sequence of the instal- lation are described in the IMON documenta- tion.

(3) After IMON installation

After successful installation, the following actions should be done:

A. Support of notification

If the SNS product (>= 1.0) is present, you can be notified on the main events occurring during the print job life and the printer session. In order to make the notifications for print jobs and printers available, some notification resources must be defined, that are specific to SPOOL. At first, check if the subsystem SNRTP is ready. If not, start it. Then, run the procedure SYSPRC.SPOOL.047.NOTIF under TSOS in order to register the spool objects and events in the notification service.

After successful installation, the following actions have to be performed:

A. the PRMMAN subsystem has to be installed.

Page 20: Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) …manuals.ts.fujitsu.com/file/6634/sysfgm.spool.047.e.pdf · The Release Notice is supplied as a text file. ... SYSSSI.SPOOLSYS.022

19

B. the SPOOL subsystem can be created using

the command /START-SUBSYSTEM SPOOL,VER- SION='<spoolver>', [SUBSYSTEM-PARAME- TER='[START=<start>],[RSO=<rso- ver>],[SPS=<sps ver>]']

where :

<start> : warm (default value) or cold

<rsover> : none (default value) or std or the version defined in 4 or 7 characters

<spsver> : none (default value) or std or the version defined in 4 or 7 characters

Remarks :

Several other files are released on the SPOOL product tape : SYSLIB.SPOOL.047 (user macros), SYSOML.SPOOL.047 (IPEXE- C10)

The backward migration of the SPOOL PARA- METER file is not possible.

The dynamic update of the installation information (SYSSII definitions) is not allowed.

5. SPOOL Add-On : SPOOL and Print Explorer Spool&Print

Explorer is available through the DESK2000 CD re- lease. Please refer to the release letter for the installation issues.

6. SPSERVE

(1) Before IMON installation

Before IMON is started, the following actions have to be performed:

Name of the product files: SPSERVE V2.8 is compliant to the IMON installation conven- tions.

Exchange of product: Not applicable.

Coexistence with other version of the product: Possible, but SPSERVE version must be compati- ble with the running SPOOL version.

Necessary privileges: Spool & Print admini- stration functions are only allowed for the users with PRINT-SERVICE-ADMINISTRATION privi- lege.

The following files must be installed on the system:

Page 21: Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) …manuals.ts.fujitsu.com/file/6634/sysfgm.spool.047.e.pdf · The Release Notice is supplied as a text file. ... SYSSSI.SPOOLSYS.022

20

A. the OML and REP-file: SYSLNK.SPSERVE.028,

SYSREP.SPSERVE.028 (from SYSRMS.SPSER- VE.028)

B. the message file: SYSMES.SPSERVE.028

C. the syntax file : SYSSDF.SPSERVE.028

D. the IMON installation file : SYS-

SII.SPSERVE.028

E. the syntax file has to be activated

F. the message file has to be activated.

(2) IMON installation

After these actions have been executed, the product has to be installed with IMON. The ne- cessary inputs and the sequence of the instal- lation are described in the IMON documenta- tion.

(3) After IMON installation, the following must be

done:

the Spool Parameters must be migrated, under the Print Services Administrator:

/START-SPSERVE //OPEN-PARAMETER-FILE *SPOOL-PARAMETERS //END

The backward migration of the SPOOL PARAMETER file is not possible. The migrated SPOOL PARA- METER file cannot be used by a previous ver- sion of SPSERVE. The old SPOOL PARAMETER file must be saved before migration if you want to use it again with a previous SPSERVE version.

The dynamic update of the installation infor- mation (SYSSII definitions) is not allowed.

7. SPSRVMAN

(1) Before IMON installation

Before IMON is started, the following actions have to be performed:

Name of the product files: SPSRVMAN V2.3 is compliant to the IMON installation conven- tions.

Exchange of product: Only after stopping the preceding version.

Coexistence with other version of the product: Impossible.

Page 22: Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) …manuals.ts.fujitsu.com/file/6634/sysfgm.spool.047.e.pdf · The Release Notice is supplied as a text file. ... SYSSSI.SPOOLSYS.022

21

Necessary privileges: Not applicable.

The following files must be installed on the system:

A. the OML and REP-file :

SYSLNK.SPSRVMAN.023 (390 platform), SPMLNK.SPSRVMAN.023 (SPARC64 platform), SYSREP.SPSRVMAN.023 (from SYSRMS.SPSRVMAN.023)

B. the message file : SYSMES.SPSRVMAN.023

C. the IMON installation file : SYS-

SII.SPSRVMAN.023

D. the system SSCM catalog has to be modi- fied in order to include the SPSRVMAN subsystem declarations,

E. the message file has to be activated.

(2) IMON installation

After these actions have been executed, the product has to be installed with IMON. The ne- cessary inputs and the sequence of the instal- lation are described in the IMON documenta- tion.

(3) After IMON installation, SPSRVMAN is automati-

cally started by SPOOL.

3.4 Product use

SPSERVE V2.8 is started using the command /START-SPSERVE.

For PRM, once the product has been installed and the subsy- stem PRMPRES started, the PRM V1.3 product may be invoked by entering the following command :

for SDF with FHS /MODIFY-JOB-SWITCHES ON=1 /START-PRM [,MONJV=xxx] /START-PRM ... ...

SDF interface OR PRM desktop ... ... //END F3 key / /

For SPOOL and Print Explorer description, please refer to the README file installed on the PC.

Note: Printing DMS PAM files can produce undesired and un- controlled results.

Page 23: Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) …manuals.ts.fujitsu.com/file/6634/sysfgm.spool.047.e.pdf · The Release Notice is supplied as a text file. ... SYSSSI.SPOOLSYS.022

22

3.5 Discontinued functions

The following functions are no longer supported as of this version:

- None

The following functions are supported in this version for the last time:

- None

3.6 Incompatibilities

SPOOL V4.7 is fully compatible with SPOOL V4.6.

SPSERVE V2.8 is fully compatible with V2.7.

PRM V1.3 is fully compatible with V1.2.

3.7 Restrictions

1. SPOOL

None

2. SPSERVE

None

3. SPSRVMAN

None

4. PRM

Special restriction : The conversion of a HP forms overlay buffer into its PCL counterpart resource (macro) does not consider the sub-fob capabilities of the HP resource, since there exists no equiva- lence in the PCL language. Therefore, a sub-fob is considered as a forms overlay buffer and converted as one entity.

5. SPOOLSYS

None.

3.8 Procedure in the event of errors

1. SPOOL

If SPOOL V4.7 error occurs, the following error in- formation is required for diagnosis: - /SHOW-SUBSYSTEM-STATUS SPOOL

- /SHOW-SPOOL-PARAMETERS

Page 24: Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) …manuals.ts.fujitsu.com/file/6634/sysfgm.spool.047.e.pdf · The Release Notice is supplied as a text file. ... SYSSSI.SPOOLSYS.022

23

- SLED, system dump or user dump of the affected SPOOL task.

- Console log or CONSLOG file

- Listings of the PRINT and SHOW commands and the

device, form and character-set definitions

- /SHOW-PRINT-RESOURCES with INFORMATION=*ALL for errors related to loop, character-image, or translation table.

- For reproducible print error conditions, use the

TRACE function that is available from the /START-PRINTER-OUTPUT (SDVC) command interface.

- If PRINT-DOCUMENT is rejected or accepted on an

unexpected printer type, re-execute the same command with the operand TRIAL-MODE=*YES. A list of more explicit messages will be displayed.

- If customized system pages are to be used, provide the corresponding template file ($SYSSPOOL.*.HEADER.* or $SYSSPOOL.*.TRAILER.* files)

2. SPSERVE

If SPSERVE V2.8 error occurs, the following error information is required for diagnosis: - System dump or user dump of the affected task.

- Console log or CONSLOG file

- Corresponding SPOOL PARAMETER file or Dprint Configuration file

- SPOOL PARAMETER file History: creation mode (SPOOL or SPSERVE), migration mode (SPOOL or SPSERVE), if any

3. PRM

If during usage of PRM, (i.e. PRMPRES and PRMMAN subsystems) error conditions occur, please prepare the following documentation : - system dump or user dump of the affected task

- Console log or CONSLOG file

- if possible the concerned PRFILE

- in case of import or migration the involved spool control file (HPFILE, FGSFILE, PCLFILE, SPOOLFILE, or TRANSFILE)

- the entered SDF statements if possible

- error code returned by FHS if any, and implied

Page 25: Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) …manuals.ts.fujitsu.com/file/6634/sysfgm.spool.047.e.pdf · The Release Notice is supplied as a text file. ... SYSSSI.SPOOLSYS.022

24

panel name or FHS DM variable name.

- The VTSU version used.

- If usage of PRM is done via OMNIS, give the parameters and settings of OMNIS. (i sys,ty=pa and i sys,ty=set)

4. SPOOLSYS

If during usage of SPOOLSYS error conditions occur, please prepare the following documentation : - system dump or user dump of the affected task

- Console log or CONSLOG file

- the entered SDF statements if possible

- if possible the concerned EQUISAMQ file(s)

4 Hardware support 1. New Hardware support

None

2. Hardware supported for the last time

None

3. Hardware no longer supported

None

Page 26: Fujitsu Siemens Computers GmbH SPOOL (BS2000/OSD) …manuals.ts.fujitsu.com/file/6634/sysfgm.spool.047.e.pdf · The Release Notice is supplied as a text file. ... SYSSSI.SPOOLSYS.022

Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu-ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So-lutions.

This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.

Please note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions.

Contact and support addresses will now be offered by Fujitsu Technology So-lutions and have the format …@ts.fujitsu.com.

The Internet pages of Fujitsu Technology Solutions are available at http://ts.fujitsu.com/... and the user documentation at http://manuals.ts.fujitsu.com.

Copyright Fujitsu Technology Solutions, 2009

Hinweise zum vorliegenden Dokument Zum 1. April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen. Diese neue Tochtergesellschaft von Fujitsu trägt seit-dem den Namen Fujitsu Technology Solutions.

Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nicht mehr im Vertrieb befindliche Produktversion.

Bitte beachten Sie, dass alle Firmenbezüge und Copyrights im vorliegenden Dokument rechtlich auf Fujitsu Technology Solutions übergegangen sind.

Kontakt- und Supportadressen werden nun von Fujitsu Technology Solutions angeboten und haben die Form …@ts.fujitsu.com.

Die Internetseiten von Fujitsu Technology Solutions finden Sie unter http://de.ts.fujitsu.com/..., und unter http://manuals.ts.fujitsu.com finden Sie die Benutzerdokumentation.

Copyright Fujitsu Technology Solutions, 2009


Recommended