+ All Categories
Home > Documents > GERDA meeting Dubna 27-29/06 /200 5

GERDA meeting Dubna 27-29/06 /200 5

Date post: 05-Jan-2016
Category:
Upload: damali
View: 54 times
Download: 1 times
Share this document with a friend
Description:
GERDA meeting Dubna 27-29/06 /200 5. Natural Ge crystal contamination measurement and Isotopic ratio determination by ICP-MS. LNGS Chemistry Service S. Nisi. Analysis method. Ge crystal dissolution HNO 3 +HF+H 2 O 1:1:1 - PowerPoint PPT Presentation
Popular Tags:
10
GERDA meeting Dubna 27-29/06/2005 LNGS Chemistry Service S. Nisi Natural Ge crystal contamination measurement and Isotopic ratio determination by ICP-MS
Transcript
Page 1: GERDA  meeting Dubna 27-29/06 /200 5

GERDA meeting Dubna 27-29/06/2005

LNGS Chemistry Service S. Nisi

Natural Ge crystal contamination measurement and Isotopic ratio

determination by ICP-MS

Page 2: GERDA  meeting Dubna 27-29/06 /200 5

Analysis method

• Ge crystal dissolution HNO3+HF+H2O 1:1:1

• Dilution of samples and spiked samples preparation to check the procedure

• Measurement of contamination and isotopic ratio by ICP-MS Agilent Technologies model 7500a (quadrupole mass analyzer)

Page 3: GERDA  meeting Dubna 27-29/06 /200 5

ICP-MS in the clean room at LNGS

Page 4: GERDA  meeting Dubna 27-29/06 /200 5

Interference on contamination measurement

ElementInterferenc

eElement

Interference

11B 10B1H, 22Ne++ N Air

27Al 31P15N16O, 30Si1H

69Ga71Ga 70Ge1H

75As 74Ge1H

113In115In

73Ge40Ar121Sb

205Tl 209Bi

232Th 238U

Page 5: GERDA  meeting Dubna 27-29/06 /200 5

Ge93 13196 contamination resultsGe93 13196 Spike

Element Ge93 13196ppm

Spike conc ppm

Meas. Conc ppm

11B <0,01   <0,0127Al 0,27 0,2 0,32

31P <2 16,5  39K <5 42 34

69Ga 0,034   0,032115In 0,014   0,1

121Sb 0,001 0,01 0,025205Tl <0,0021 0,01 0,0089209Bi <0,0019   <0,0018232Th <0,0016 0,01 0,0089238U <0,0015 0,01 0,0092

Page 6: GERDA  meeting Dubna 27-29/06 /200 5

Ge124 11888 contamination results

Ge124 11888 Spike

Element Ge124 11888ppm

Spike conc ppm

Meas. Conc ppm

11B <0,01   <0,0127Al 0,22 0,2 0,3531P <2 16,5  39K <5 42 33

69Ga 0,031   0,033115In 0,0038   0,13

121Sb 0,0013 0,01 0,009205Tl <0,0019 0,01 0,0093209Bi <0,0016   <0,0018232Th <0,0014 0,01 0,009238U <0,0013 0,01 0,0096

Page 7: GERDA  meeting Dubna 27-29/06 /200 5

Ge crystal contamination comparison

Element nat Ge X8ppm

Ge93 13196 ppm

Ge12411888

ppm11B <0,01 <0,01 <0,01

27Al 0,32 0,27 0,2231P <2 <2 <239K <5 <5 <5

69Ga 0,039 0,034 0,031115In 0,006 0,014 0,0038

121Sb 0,0036 0,001 0,0013205Tl <0,0021 <0,0021 <0,0019209Bi <0,0018 <0,0019 <0,0016232Th <0,0015 <0,0016 <0,0014238U <0,0014 <0,0015 <0,0013

Page 8: GERDA  meeting Dubna 27-29/06 /200 5

Ge isotopic measurement for GNO

Ge70%

Ge72%

Ge73%

Ge74%

Ge76%

Carrier 70Ge

96,47

96,784

1,14

1,090

0,35

0,320

1,46

1,316

0,57

0,490

Carrier 72Ge

0,36

0,355

98,54

98,609

0,23

0,223

0,73

0,683

0,14

0,129

Carrier 74Ge

0,42

0,444

0,64

0,639

0,23

0,230

98,5

98,486

0,21

0,201

BLUE VALUE=LNGS measure carried out by ICP-MS (quadrupole mass analyzer)RED VALUE=MC-ICP-MS (double focusing-multicollector) carried out from ITU of JRC Karlsrhue

Page 9: GERDA  meeting Dubna 27-29/06 /200 5

Ge crystal isotopic ratio measurement

GeX8%

Ge93 13196%

Ge124 11888

%

70Ge 19,08+/-0,10 19,14 +/-0,07 19,18 +/-0,09

72Ge 27,00 +/-0,13 26,95 +/-0,14 26,80 +/-0,09

73Ge 7,81 +/-0,04 7,76 +/-0,04 7,82 +/-0,07

74Ge 37,58 +/-0,21 37,63 +/-0,13 37,61 +/-0,24

76Ge 8,53 +/-0,10 8,52 +/-0,05 8,59 +/-0,05

Page 10: GERDA  meeting Dubna 27-29/06 /200 5

Conclusion

• Concerning the contamination measurement of Ge crystal could be possible a little improvement (2or3 factor) of the sensitivity for some elements but we are close to the DL

• About the isotopic composition will be possible measure the enriched crystal with the same accuracy and precision


Recommended