April 14, 2007
Project Objectives
□To build a functioning circuit board with a microprocessor by soldering different components to the board.
□To construct a sensor board that will connect to the circuit board.
□Write a computer program that will display the temperature sensor reading onto the lcd display of the circuit board.
MSP430 Chip
□ Voltage supply of 1.8 to 3.6 V□ 16-bit design□ 12-bit A/D converter□ 5 power saving modes□ Serial onboard programming□ On-chip comparator□ 60 kB flash memory, 2048 B RAM□ Low power to active mode in less than 6
microseconds
Completed Circuit Board
AD590 Temperature Sensor
9 V ba t te ry
9 V ba t te ry
B
A
C
D P D T s w itc h
V o ltag eS up p lyfo r p ro tob o ard
C (+ 9 V )
B (g rd )
+
_
A D 5 9 0 s e n s o r
7 4 1
B
pin 7
pin 4
pin 6pin 2
pin 3
C
A
+
_+
_
V S
R FB
R IN
1 0 k
1 .8 k
1 k
+
_
V O
T o A /D c o n v e rte ro f th e m s p 4 3 0
• •a b
1 0 0 pot
1 k
•Sensor Output: 1μA/˚K
•Supply voltage: 4 to 30 V
•Temperature range: -55 to 150 ˚C
•2 terminals: voltage in, current out
•Calibration required
AD22103 Temperature Sensor
•Supply voltage: 2.7 to 3.6 V
•Temperature range: 0-100 ˚C
•Temperature coefficient: 28mV/ ˚C
•Transfer function:
V0=(Vs/3.3V)*[0.25V+(28mV/˚C)*TA]
•On-chip signal conditioning – no need to calibrate
Computer Programming
Program Modifications:□ Added 7th order filter□ Conversions from
Kelvin to Celsius and Fahrenheit
□ Change input from sensor to Celsius from Kelvin with new sensor
Filtering:□ 7th order filter allows
the output to be a better representation of the current temperature because the past seven data points have been averaged
□ This can also cause a delay when the sensor is first activated
Troubleshooting
□ Check all pin connections on the circuit board.□ Make sure all components of the sensor board are
wired and powered correctly.□ Test operational amplifier and MSP430 against
working standards.
Success!
Sensor Readings
Temperature vs. Time
0
5
10
15
20
25
30
35
0 50 100 150 200 250 300
Time (sec)
Te
mp
era
ture
(d
eg
ree
s C
)
AD590
22103
Why does the temperature increase quickly and decrease slowly upon placing and releasing a heat source?
Questions?