H a zardous A r e a L i g h t i n g
Transcript
Page 1: Hazardous Area Lighting

8/8/2019 Hazardous Area Lighting

http://slidepdf.com/reader/full/hazardous-area-lighting 1/16

Hazardous Area Lighting

Page 2: Hazardous Area Lighting

8/8/2019 Hazardous Area Lighting

http://slidepdf.com/reader/full/hazardous-area-lighting 2/16HAZARDOUS A

INTRODUCTION

Flam eproof Bulkhead Lum inaire

Flam eproof Lum inaire For Fluorescent

Tubular Lam p

Flam eproof Non-integral W ellglass

Lum inaire

Flam eproof Aviation Obstruction Light

Flam eproof Control Gear Box

Increased Safety Non Integral W ellglass

Lum inaire

Increased Safety Integral W ellglass Lum inaire

Control Gear Box for Increased Safety Lum inaire

Flam eproof Integral W ellglass Lum inaire

Flam e Proof Non-integral Flood Light

Page 3: Hazardous Area Lighting

8/8/2019 Hazardous Area Lighting

http://slidepdf.com/reader/full/hazardous-area-lighting 3/16EA LIGHTING

Hazardous Area Lighting

In the areas where flam m able m aterials are m anufactured, produced, processed or stored, m ixing of flam m able gases with air

is likely to happen in the atm osphere. If due to the electrical equipm ent installed in such areas, ignition takes place due to a

spark or fire, it can lead to a hazardous situation. Although the prim e requirem ent is to avoid the occurrence of such conditions

where this is not practical, special m ethods of safeguarding electrical apparatus m ust be em ployed.

Care should be taken to avoid flam m able or explosive atm ospheres, inorder to have an ignition, both a flam m able atm osphereand m eans of ignition m ust exist sim ultaneously.

Types of Hazardous situations :

Depending on the presence of flam m able m aterial the hazardous areas are classified in to Hazardous Zones.

Typical illustration of Zone 0, Zone 1, Zone 2 areas

with source of ignition

ZONE 2

ZONE 1

ZONE 0

(SOURCE)

ZONE 0

ZONE 1

ZONE 2

THE EXPLOSIVE ATM OSPH ERE IS CONTINUOUSLY PRESENT

THE EXPLOSIVE ATM OSPH ERE IS OFTEN PRESENT

THE EXPLOSIVE ATMOSPHERE IS ACCIDENTALLY PRESENT

 A Zone in w hich an explosive m ixture is continuously present (in the gaseous phase) inside a receptacle or a

closed cham ber constitute Zone 'O’

 A Zone in w hich an explosive m ixture of Gas, Vapour or Dust is likely to occur in normal operations. In these areas

flam eproof lum inaires and accessories are used.

Flam eproof Enclosure - is one which will withstand w hen all the covers and accessories are properly secured, an

internal explosion of the flam m able gas or vapour through the joint gaps and flam e paths provided in the enclosure.

Note: The term 'Flam eproof' is synonym ous with the term 'Explosion-proof' as used in USA or 'Explosion-Proof' type

'd' protection used in Germ any and other Continental countries.

 A Zone in which an explosive m ixture is not likely to occur in normal operations and if it occurs will only exist for a

short tim e (Leaks or negligent use). In these areas, Increased Safety Lum inaires are used and are generally

provided with gaskets and special lam p holders in case of fittings. These equipm ents are m anufactured as per IS

8224/1976 and IS 6381/1972.

Page 4: Hazardous Area Lighting

8/8/2019 Hazardous Area Lighting

http://slidepdf.com/reader/full/hazardous-area-lighting 4/16HAZARDOUS A

It should be noted that fittings com plying with the requirem ents as specified in IS 8224/1976 are not suitable for gases oro

vapour having ignition tem perature below 200 C. The follow ing is the list of gases or vapours know n to have self/auto ignitiono

tem perature below 200 C.

1. Ethyl nitrate 2. Isopropyl nitrate

3. Carbon disulphide 4. Acetaldehyde

5. Diethyl ether 6. Diproplyl ether7. Dibutyl ether 8. Diam yl ether9. Dihexyl ether 10. Benxaldyhyde11. Ethyl M ethyl ether 12. Diethyl peroxide

Tem perature Classes

Ignition tem perature is the lowest tem perature at which a flam m able gas m ixture ignites. Flam m able vapours and gases can be

classified into tem perature classes according to their ignition tem perature. Surface tem perature of the lum inaire is likely to be

higher than am bient tem perature due to heat generated during fire or explosion inside the enclosure. The m axim um surface

tem perature of the lum inaire m ust always be low er than the ignition tem perature of the gas m ixture present in the air.

Lum inaire of appropriate specified tem perature class should be selected based on the ignition tem perature of the gas.

Dust proof / Dust-tight

Lum inaires are m anufactured as per IS 4012 / IS 4013-1967 and are recom m ended to be installed in industries where in

addition to the recognized explosives, m any other dusts including practically all organic and inorganic dust, (dust of m etals are

flam m able to som e extent depending on the particle size), specific gravity of dust etc. are present.

Dusts have been broadly classified into the follow ing groups.

Class 1 Dust which ignite and propagate flam e readily, the source of heat required for ignition being sm all.

Class 2 Dust which ignite readily with flam e but require a larger source of ignition.

Class 3 Dust which do not ignite.

Dust-tight lum inaires are recom m ended for locations laden with Class 1 Dust. For other class of dust, dustproof lighting fittings

m ay be used.

Temperature Class Maximum Surface Temperatureof Luminaires ( C)

T1 450

T2 300

T3 200

T4 135

T5 100

T6 85

z

Page 5: Hazardous Area Lighting

8/8/2019 Hazardous Area Lighting

http://slidepdf.com/reader/full/hazardous-area-lighting 5/16EA LIGHTING

Group of

Enclosures

I

II A

Gas or Vapour

M ethane (fire dam p)

 Am m onia, Industrial m athane*, Blast furnace gas, Carbon m onoxide, Propane, Butane, Pentane, Hexane, Heptane,

Iso-Octane, Decane, Benzene, Xylene, Cyclohexane, Acetone, Ethyl m ethyl Ketone, M ethyl acetate, Ethyl acetate,

N-propyl acetate, N-butyl acetate, Am yl acetate, Chlorothylene, M ethanol, Ethanol, ISO-butanol, N-Butanol, Am yl alcohol,

Ethyl nitrate.

Hydrogen

II B

II C

1, 3-Butadine, Ethylene, Diethyl ether, Ethylene oxide, Town gas, Coke-oven gas.

Drip proof IP 22Rain proof IP 23

Splash proof IP 34

Dustproof / Splashproof IP 54

Dustproof / Jetproof IP 55

Dust-tight / Jetproof IP 65

Ingress Protection System for Enclosures (IP)

This system outlined in IS 2147 is designed to indicate the standard degree of protection: (a) from ingress of solids and (b) from

ingress of liquids which enclosures m ay exhibit and m ust not be confused with explosion protection techniques.

For lum inaires the following IP num bers com m only apply :

Higher the num erical of the first and second characteristic, the greater degree of protection the enclosure offers. E.g. Jetproof

IP 55 m eets all the less onerous degrees such as IP 22, IP 23, IP 34 and IP 54.

Testing Authorities

 All our Flam eproof and Increased safety lum inaires are tested and Certified by Central Institure of M ining and Fuel Research(CIM FR), Dhanbad.

Standards

(a)Flam eproof Construction : IS:2148-2004 (IEC 60079-1/2001)

(b)General design, rating, perform ance & T-class : IS:13346-2004 (IEC 60079-0/2000)

(c ) W eatherproof construction IP-65 : IS:12063-1987 (IEC 60529/1989)

Table 3 of IS 2148/1981

G roup of Enclosures Suitable for Particular Flam m able G as or Vapour (Clauses 1.4 and 3.1.2)

*Industrial M ethane includes m ethane m ixed with not m ore than 10% by volum e of hydrogen.Town gas m ay contain not m ore

than 57% by volum e of hydrogen and not m ore than 16% by volum e of carbon m onoxide, the rem ainder being a m ixture of

paraffin hydrocarbons and inert gas.

---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Note :

Due to our continuous efforts in developing products, im provem ent - Bajaj Electricals Lim ited reserves the right to m ake changes in the

design and data without any prior notice.

Page 6: Hazardous Area Lighting

8/8/2019 Hazardous Area Lighting

http://slidepdf.com/reader/full/hazardous-area-lighting 6/16

BJFB 150/200 BC/ES (LM 6)

Lum inaire Body

Lam p

Temperature Range

CIM FR Certificate

Epoxy finish Cast Alum inium LM 6 housing.

Toughened Type A flat glass.

Two cable entries of 3/4” BS conduit are provided.

Lam p holder suitable for lam p type w ill be provided (2 pin BC / 3 pin BC / E 27)

Suitable for 100W /150W /200W GLS, 80W /125W HPM V,

70W SV/M H/150W M H (E27) 160W M LL, 26W CFL - Retrofit.

80W M V/70W SV/ 70W M H/100W GLS - T4

125M V/150W M H/150W GLS/200W GLS /160W M LL T3

26W CFL - Retrofit - T6

Suitable for Zone 1 & 2 areas where explosive gasses specified under gasgroups IIA & IIB are present. This is a non integral lum inaire suitable for indoor

application. Separate control gear to be used in case of HID lam ps.

CIM FR/TC/SR/H909 DATED 08.02.2008

Flam eproofBulkhead Lum inaire

Lum inaire Body

Lam p

Temperature Range

Ingress Protection

CIM FR Certificate No

Note

Cast Alum inium LM 6 housing w ith Epoxy finish. Heat resistant borosilicate

tubular glass held in two alum inium cups. Two cable entries of 3/4” BSconduit are provided.

Single or Twin 36W /40 W Fluorescent Tubular lam p/28W T5 lam p. Special

variant for 18W /20 W FTL also available.

T6

IP 65

Suitable for Zone 1 & 2 areas where explosive gasses specified under gasgroups IIA & IIB are present.

CIM FR/TC/SR/H798 DTD 11.01.2008

External Stove Enam eled Reflector can be provided as an additional feature

Flam eproof Lum inaire

For Fluorescent Tubular Lam p

BJFFTL 136/236, 140/240, 128/228

228 135

380

BJFFTL-140 BJFFTL-240

235

170

267

170

125

235

BJFFTL-140/240

1590

235

Page 7: Hazardous Area Lighting

8/8/2019 Hazardous Area Lighting

http://slidepdf.com/reader/full/hazardous-area-lighting 7/16

Lum inaire Body

Lam p

Temperature Range

Ingress Protection

CIM FR Certificate No

Cast Alum inium LM 6 housing w ith Epoxy finish. Heat resistant and

toughened glass enclosure type A with BC/E27 lam p holder Painted M S

wire guard. Two cable entries of 3/4” BS conduit are provided. Separateflam eproof control gear box of suitable rating to be used for HID lam ps.

Suitable for 80/125W M V, 70W SV/M H, 150W M H (E27), 200W GLS,

160W M LL, 23W /26W Retrofit CFL lam p.

150W M H (E27), 200W GLS, 160W M LL - T3125W M V - T4

80W M V/ 70W SV/ 70W M H - T523W /26W Retrofit CFL - T6

Ideal for use in Zone 1 & 2 areas where explosive gasses specified under gasgroups IIA & IIB are present.

IP 65

CIM FR/ TC/ SR/ H 1136 DATED 19.03.2008

Flam eproof Non-integral W ellglass Lum inaire

BJFW 80/125 M V NI BC/ES LM 6

247

402

Lum inaire Body

Lam p

Temperature Range

Ingress Protection

CM RI Certificate N o

Cast Alum inium LM 6 housing w ith Epoxy finish. Heat resistant and

toughened glass enclosure type A. Painted M S wire guard. Two cable entriesof 3/4” BS conduit are provided. Available in cast iron version for special

application areas also. This is a non-integral lum inaire. Separate flam eproofcontrol gear box to be used as per the lam p rating.

250 W HPM V, 400W HPM V, 250W HPSV, 400W HPSV, 400W M H lam p.

250W /400W HPM V - T3, 250W HPSV - T5, 400W HPSV/M H - T4

Suitable for use in Zone 1 & 2 areas where explosive gasses specified under

gas groups IIA & IIB are present.

IP 65

CM RI/TC/P/H/382 DTD 18.08.2006

BJFW 400 M V CA (NI)

BJFW 400 SV/M H CA (NI) / BJFW 250 SV (NI)

Flam eproof Non-integral W ellglass Lum inaire

      5      3      0

Ø335

100100

 A = 3 Nos.,Ø12.5 HOLE

 A A A

Page 8: Hazardous Area Lighting

8/8/2019 Hazardous Area Lighting

http://slidepdf.com/reader/full/hazardous-area-lighting 8/16

BJFW 250 M V I CA

BJFW 150 SV/M H I

Lum inaire Body

Lam p

Temperature Range

Ingress Protection

CIM FR Certificate No

Cast Alum inium LM 6 housing w ith Epoxy finish. Heat resistant andtoughened glass enclosure type A. Painted M S wire guard. Two cable entries

of 3/4” BS conduit are provided. This is an integral lum inaire HID Ballast &

accessories fitted inside the housing.

Suitable for 150W HPSV/M H lam p, 250 HPM V lam p.

T 4

Ideal for use in Zone 1& 2 areas where explosive gasses specified under gas

groups IIA & IIB are present.

IP 65

CM RI/TC/P/H 378 DATED 18.08.2006

Flam eproofIntegralW ellglass Lum inaire

ForH PM V/H PSV And M etalHalide Lam p

Lum inaire Body

Lam p

Temperature Range

Ingress Protection

CIM FR Certificate No

Note

Cast Alum inium LM 6 housing with Epoxy finish. Heat resistant and

toughened glass enclosure-type A. Painted M S wire guard. Two cable entries

of 3/4” BS conduit are provided. This is an integral lum inaire. HID ballastand accessories fitted inside the housing.

Suitable for 80W /125 W HPM V, 70W HPSV/M H lamp.

T 4

Ideal for use in Zone 1& 2 areas where explosive gasses specified under gas

groups IIA & IIB are present.

IP 65

CIM FR/TC/SR/H840 DATED 24.01.2008

This lum inaire can also be used as non integral for 250W M V/150SV/150 M H BJFW 250 W M V (NI),

BJFW 150 W SV (NI), BJFW 150 W M H (NI)

Flam eproof Integral W ellglass Lum inaire

For HPM V/HPSV and M etal Halide Lamp

BJFW 80/125 M V I CA BC/ES

BJFW 70 SV/M H I

245

480

BJFW 250 M V I

      5      3      0

Ø247

Page 9: Hazardous Area Lighting

8/8/2019 Hazardous Area Lighting

http://slidepdf.com/reader/full/hazardous-area-lighting 9/16

Lum inaire Body

Lam p

Temperature Range

Ingress Protection

CM RI CERTIFICATE NO

Cast Alum inium LM 6 Epoxy finish lam p housing. Heat resistant and

toughened flat glass Type A. One Cable entry through 3/4” BS conduit. This

is a non integral lum inaire and suitable flam eproof control gearbox shouldbe separately used.

Ideal for use in zone 1 & 2 areas where explosive gasses specified under gas

groups IIA & IIB are present.

Suitable for 250 HPM V/250W HPSV/400W HPSV/400W M H.

250W M V - T5 , 400W SV/M H - T4, 250W SV T6.

IP 65

CM RI/TC/P/H 387 DTD. 21.08.2006

Flam eproof Non-integral Flood Light

BJFFL 250/400 NI

Lum inaire Body

Lam p

Tem perature Class

Ingress Protection

CM RI CERT.NO

Cast alum inum LM 6 yellow epoxy pow der coated housing. Heat resistant

and toughened type A glass enclosure. Two cable entries of 3/4” BS conduit

are provided.Ideal for use in zone 1 & 2 areas where explosive gasses specified under gasgroups IIA & IIB are present.

Suitable for Neon spiral lam p 75VA

T6

IP 65

CM RI /TC/P/H354 dt. 10th Aug 2006.

Flam eproof Aviation Obstruction Light

BJFAOL 01

      7      0      0

      Ø

      3      7      5

100 100

500

BJFFL 250/400 MV N I

      4      9      5

Ø38

Ø245

BJFAOL-01

Page 10: Hazardous Area Lighting

8/8/2019 Hazardous Area Lighting

http://slidepdf.com/reader/full/hazardous-area-lighting 10/16

BJFC 80W /125W /250W M V CA

BJFC 70W /150W SV/M HBJFC 400 M V/SV/M H

Housing

Lam p

Temperature Range

Ingress Protection

CIM FR Certificate No

Die-cast alum inium LM 6 housing. Com pletely wired w ith control gearaccessories. Three cable entries of 3/4” BS conduit are provided. Ideal for

use in ZONE 1 & 2 areas where explosive gasses specified under gas groups

IIA & IIB are present.

Versions available for 80W /125W /250W HPM V lam p, 70W /150WHPSV/M etal Halide lam p and 3 X 26W CFL. Also available for 400W

HPM V/400W HPSV/M H lam p.

T6

IP65

CIM FR/TC/SR/H800 DTD. 15/01/2008 for 80W /125W /250 HPM V,70/150SV/M H

CIM FR/TC/SR/H837 DTD. 23/01/2008 for 400W HPM V/HPSV/M H lamps.

Flam eproofControlGearBox

Lum inaire Body

Lam p

Ingress Protection

Tem perature Class

CM RI Certification

 Applicable standards and certification

Cast Alum inium LM 6 housing with Epoxy finish. Heat resistant well glass

cover. Painted M S w ire guard. Two cable entries of 3/4” BS conduit areprovided. This is a dustproof, dust tight, totally enclosed, increased safety

non-integral lum inaire. Separate increased safety control gear box to beused as per Zone 2 the lam p rating.

Suitable for 150/200W GLS, 160W M LL , 80W /125W HPM V, 70W HPSV

- Elliptical, 23 W Retrofit CFL.

IP 65

CM RI/TC/P/H1335 DTD 10.11.1998

lS : 2147-1962 Specification for Degree of protectionlS : 8224-1976 Specification for Electric Lighting Fittings for Divn. 2 areas

lS: 6381/1972 Specification of Electrical Apparatus w ith type of

protection 'e'lS: 6381/1972 Specification of construction of Electrical Apparatus with

type of protection 'e'lS : 13947 (part 1) 1993 for lP 65

Increased Safety Non-Integral

W ellglass Lum inaire

BJDP/DT/TE/ISW -200 LM 6 NI

Volts 250 Max. GLS HPMV MLL SV CFL

150W 200W 80W 125W 160W 70W 23W

Temperature Classification T5 T5 T6 T5 T5 T6 T6

320

210

      3      3      5 2

      0      5

235

238

      1      1      1

Page 11: Hazardous Area Lighting

8/8/2019 Hazardous Area Lighting

http://slidepdf.com/reader/full/hazardous-area-lighting 11/16

Lum inaire Body

Lam p

CM RI Certification

 Applicable standards and certification

Cast Alum inium LM 6 housing w ith Epoxy finish. Heat resistant and

toughened glass cover-type A. Painted M S wire guard. Two cable entries of

3/4” BS conduit are provided.

Ideal for use in areas where explosive or ignitable gases are present (Division

2 areas).

Ingress protection: IP 65

Suitable for 80/125W M V lam p, 70W HPSV lam p. HID ballasts andaccessories wired inside the housing. It can also be used for 250W HPM V as

non integral lum inaire. Separate control gear box to be used for 250W

HPM V version - BJISW 250 M V N I.

This lum inaire has been tested and certified by CM RI, Dhanbad vide theirletter Ref. No.

CM RI/TC/P/H1260 DATED 14-10-1999CM RI/TC/ADDEN/H193 DATED 16-02-2000

CCE No. R1(1) 136/ALPINE/418 dated 15-02-2000

IS :2147-1962 Specification for Degree of protection

lS :8224/1976 Specification for Electric Lighting Fittings for Divn.2 areaslS:6381/1972 Specification of construction of Electrical Apparatus w ith

type of protection 'e'lS :13947 (part 1) 1993 for IP 65.

Lum inaire Body

Lam p

Ingress Protection

CM RI Certification

 Applicable standards and certification

Cast Alum inium LM 6 housing with Epoxy finish. Heat resistant well glass

cover, Ideal for use in Zone 2. Painted M S wire guard. Two cable entries of

3/4” BS conduit are provided. This is a dustproof, dust tight, totallyenclosed, increased safety non-integral lum inaire. Separate increased

safetycontrolgearboxtobeusedasperthelam prating.

Suitable for 150/200W GLS, 160W M LL , 80W /125W HPM V, 70W HPSV- Elliptical, 23 W Retrofit lam p.

IP 65

CM RI/TC/P/H1455 Dated 26.11.98 for BJISW

lS :2147-1962 Specification for Degree of protection

lS :8224-1976 Specification for Electric Lighting Fittings for Zone 2 areas

lS:6381/1972 Specification of Electrical Apparatus with type ofprotection 'e'

lS:6381/1972 Specification of construction of Electrical Apparatus withtype of protection 'e'

lS : 13947 (part 1) 1993 for lP 65

Increased Safety Non-Integral

W ellglass Lum inaire

BJISW 80/125 M V NI/70 SV NI BJISW 80/125 M V (I)

BJISW 70SV (I)

210

320

Volts 250 Max. GLS HPMV BLL SV CFL

150W 200W 80W 125W 160W 70W 23W

Temperature Classification T5 T5 T6 T5 T5 T6 T6225

390

Increased Safety Integral W ellglass Lum inaire

Page 12: Hazardous Area Lighting

8/8/2019 Hazardous Area Lighting

http://slidepdf.com/reader/full/hazardous-area-lighting 12/16

BJISCG 80/125/250 M V

BJISCG 70/150 SV

HOUSING

Lam p

Ingress Protection

CM RI Certificate No

Die-cast alum inium LM 6 housing. Com pletely wired w ith control gearaccessories. Three cable entries of 3/4” BS conduit are provided.

Ideal for use in Zone 1 & 2 areas where explosive or ignitable gas m ixturesare present for a short period.

Suitable for 80/125W HPM V, 70W HPSV, 150W HPSV, 250M V lamp.Prewired with open construction ballast and accessories suitable for lam p

rating.

IP 65

CM RI /TC/P/SL/H1454 DTD 26/11/1998 for 80W /125W HPM V, 70W

HPSVCM RI/TC/P/H1361 DTD 12.01.1999 for 250W HPM V, 150W HPSV

210

103

215

200 C/C

102 C/C210

Control Gear Box

for Increased Safety Lum inaire

Page 13: Hazardous Area Lighting

8/8/2019 Hazardous Area Lighting

http://slidepdf.com/reader/full/hazardous-area-lighting 13/16

FLAM EPROOF LUM INAIRES PRODUCT RANGE DETAILS

SR. NO. CIM FR REVALIDATION CIM FR SUPPLIM ENTARY ITEM CAT NOS. LAM P RATING TEM P. IP ZONE GASCERTIFICATE CERTIFICATE TO RANGE GROUPNO. & DATE REVALIDATION

CERTIFICATE NO. & DATE

1 CIM FR/TC/SR/H840 CIM FR/TC/S/693 BJFW - 250 BJFW - 250 M V (NI) 250 W HPM V T 3 IP 65 1 & 2 IIA & IIB

DTD. 24.01.2008 DTD.19.11.2008 FLAM EPROOF/W P BJFW - 80 M V (I) 80 W HPM V IP 65 1 & 2 IIA & IIB

W ELLGLASS BJFW - 125 M V (I) 125 W HPM V T 4 IP 65 1 & 2 IIA & IIB

LUM INAIRES BJFW - 70 SV (I) 70 W HPSV IP 65 1 & 2 IIA & IIB

BJFW - 70 M H (I) 70 W M H IP 65 1 & 2 IIA & IIB

BJFW - 150 SV (NI) 150 W HPSV T 4 IP 65 1 & 2 IIA & IIB

BJFW - 150 M H (NI) 150 W M H T 4 IP 65 1 & 2 IIA & IIB

BJFW - 150 MH (E27) (I) 150 W MH (E27) T 3 IP 65 1 & 2 IIA & IIB

BJFW - 3X26 CFL (I) 3X26 W CFL T 6 IP 65 1 & 2 IIA & IIB

BJFW - 300 GLS 300 W GLS IP 65 1 & 2 IIA & IIB

2 CIM FR/TC/SR/H1136 CIM FR/TC/S/694 BJFW - 80/125 BJFW - 80 M V (NI) 80 W HPM V T 5 IP 65 1 & 2 IIA & IIB

DTD. 19.03.2008 DTD.19.11.2008 FLAM EPROOF/W P BJFW - 125 M V (NI) 125 W HPM V T 4 IP 65 1 & 2 IIA & IIB

NON-INTEGRAL BJFW - 70 SV (NI) 70 W HPSV T 5 IP 65 1 & 2 IIA & IIB

W ELLGLASS BJFW - 70 M H (NI) 70 W M H T 5 IP 65 1 & 2 IIA & IIB

LUMINAIRES BJFW - 150 SV (E27)(NI) 150 W MH (E27) T 3 IP 65 1 & 2 IIA & IIBBJFW - 1X23 CFL (NI) 23 W CFL T 6 IP 65 1 & 2 IIA & IIB

BJFW - 3X26 CFL (NI) 3X26 W CFL T 6 IP 65 1 & 2 IIA & IIB

BJFW - 200 GLS (NI) 200 W GLS T 3 IP 65 1 & 2 IIA & IIB

BJFW - 160 M LL (NI) 160 W M LL T 3 IP 65 1 & 2 IIA & IIB

3 CIM FR/TC/SR/H800 CIM FR/TC/S/696 BJFC - 80/125/250 BJFC - 80 M V 80 W HPM V IP 65 1 & 2 IIA & IIB

DTD.15.01.2008 DTD.19.11.2008 FLAM EPROOF/W P BJFC - 125 M V 125 W HPM V IP 65 1 & 2 IIA & IIB

CONTROL BJFC - 250 M V 250 W HPM V T 6 IP 65 1 & 2 IIA & IIB

GEAR BOX BJFC - 70 SV 70 W HPSV T 6 IP 65 1 & 2 IIA & IIB

BJFC - 70 M H 70 W M H T 6 IP 65 1 & 2 IIA & IIB

BJFC - 150 SV 150 W HPSV T 6 IP 65 1 & 2 IIA & IIB

BJFC - 150 M H 150 W M H T 6 IP 65 1 & 2 IIA & IIB

BJFC - 3X26 CFL 3X26 W CFL T 6 IP 65 1 & 2 IIA & IIB

4 CIM FR/TC/SR/H837 CIM FR/TC/S/697 BJFC - 400 M V BJFC - 400 M V 400 W HPM V T 6 IP 65 1 & 2 IIA & IIB

DTD.23.01.2008 DTD.19.11.2008 FLAM EPRROF/W P BJFC - 400 SV 400 W HPSV T 6 IP 65 1 & 2 IIA & IIB

CONTROL BJFC - 400 M H 400 W M H T 6 IP 65 1 & 2 IIA & IIBGEAR BOX

5 CIM FR/TC/SR/H909 CIM FR/TC/S/695 BJFB - 150/200 BJFB - 80 M V 80 W HPM V T 4 - 1 & 2 IIA & IIB

DTD.08.02.2008 DTD.19.11.2008 FLAM EPROOF BJFB - 125 M V 125 W HPM V T 3 - 1 & 2 IIA & IIB

BULK HEAD BJFB - 70 SV 70 W HPSV T 4 - 1 & 2 IIA & IIB

LUM INAIRE BJFB - 70 M H 70 W M H T 4 - 1 & 2 IIA & IIB

BJFB - 150 SV 150 W HPSV T 3 - 1 & 2 IIA & IIB

BJFB - 150 M H 150 W M H T 3 - 1 & 2 IIA & IIB

BJFB - 160 M LL 160 W M LL T 3 - 1 & 2 IIA & IIBBJFB - 1X26 CFL 26 W CFL T 6 - 1 & 2 IIA & IIBBJFB - 100 GLS 100 W GLS T 4 - 1 & 2 IIA & IIBBJFB - 150 GLS 150 W GLS T 3 - 1 & 2 IIA & IIBBJFB - 200 GLS 200 W GLS T 3 - 1 & 2 IIA & IIB

6 CIM FR/TC/SR/H798 CIM FR/TC/S/H438 BJFFTL - 140 BJFFTL - 140 1X40 W FTL T 6 IP 65 1 & 2 IIA & IIBDTD.11.01.2008 DTD.03.09.2008 FLAM EPROOF/W P BJFFTL - 240 2X40 W FTL IP 65 1 & 2 IIA & IIB

FLUORESCENT BJFFTL - 136 1X36 W FTL T 6 IP 65 1 & 2 IIA & IIB

CIM FR/Amend/FLP/Oct./588 TUBE LIGHT BJFFTL - 236 2X36 W FTL IP 65 1 & 2 IIA & IIBDTD.17.10.2008 LUM INAIRE BJFFTL - 120 1X20 W FTL T 6 IP 65 1 & 2 IIA & IIBBJFFTL - 220 2X20 W FTL IP 65 1 & 2 IIA & IIBBJFFTL - 118 1X18 W FTL T 6 IP 65 1 & 2 IIA & IIBBJFFTL - 218 2X18 W FTL IP 65 1 & 2 IIA & IIBBJFFTL - 128 1X28 W (T5) IP 65 1 & 2 IIA & IIBBJFFTL - 228 2X28 W (T5) IP 65 1 & 2 IIA & IIBBJFFTL - 114 1X14 W (T5) IP 65 1 & 2 IIA & IIBBJFFTL - 214 2X14 W (T5) IP 65 1 & 2 IIA & IIBBJFFTL - 1X20 CFL 1X20 W CFL T 6 IP 65 1 & 2 IIA & IIB

7 CIM FR/TC/SR/H808 BJFJB - 100 BJFJB - 100 - - IP 65 1 & 2 IIA & IIBDTD.16.01.2008 FLAM EPROOF/W P

JUNCTION BOX

Page 14: Hazardous Area Lighting

8/8/2019 Hazardous Area Lighting

http://slidepdf.com/reader/full/hazardous-area-lighting 14/16

FLAM EPROOF LUM INAIRES PRODUCT RANGE DETAILS

SR. NO. CIM FR REVALIDATION CIM FR SUPPLIM ENTARY ITEM CAT NOS. LAM P RATING TEM P. IP ZONE GASCERTIFICATE CERTIFICATE TO RANGE GROUPNO. & DATE REVALIDATION

CERTIFICATE NO. & DATE

8 CM RI/TC/P/H382 BJFW - 400 M V (NI) BJFW - 400 M V (NI) 400 W HPM V T 3 IP 65 1 & 2 IIA & IIBDTD.18.08.2006 FLP/W P BJFW - 400 SV (NI) 400 W HPSV T 4 IP 65 1 & 2 IIA & IIB

W ELLGLASS BJFW - 400 M H (NI) 400 W M H T 4 IP 65 1 & 2 IIA & IIBREVALIDATION NOT LUM INAIRE BJFW - 250 SV (NI) 250 W HPSV T 5 IP 65 1 & 2 IIA & IIBREQUIRED AS TESTEDBYCM RI AS PER REVISEDBIS STANDARDS

9 CM RI/TC/P/H387 BJFFL-250/400 M V BJFFL - 250 M V (NI) 250 W HPM V T 5 IP 65 1 & 2 IIA & IIBDTD.21.08.2006 NON-INTEGRAL BJFFL - 250 SV (NI) 250 W HPSV T 6 IP 65 1 & 2 IIA & IIB

FLAM EPROOF/W P BJFFL - 400 SV (NI) 400 W HPSV T 4 IP 65 1 & 2 IIA & IIBREVALIDATION NOT FLOOD LIGHT BJFFL - 400 M H (NI) 400 W M H T 4 IP 65 1 & 2 IIA & IIBREQUIRED AS TESTED LUM INIAREBYCM RI AS PER REVISEDBIS STANDARDS

10 CM RI/TC/P/H378 BJFW - 250 M V (I) BJFW - 250 M V (I) 250 W HPM V T 4 IP 65 1 & 2 IIA & IIBDTD.18.08.2006 FLAM EPROOF/W P BJFW - 150 SV (I) 150 W HPSV T 4 IP 65 1 & 2 IIA & IIB

W ELLGLASS BJFW - 150 M H (I) 150 W M H T 4 IP 65 1 & 2 IIA & IIB

REVALIDATION NOT LUM INIAREREQUIRED AS TESTEDBYCM RI AS PER REVISEDBIS STANDARDS

11 CM RI/TC/P/H354 BJFAOL - 01 BJFAOL - 01 NEON SPIRAL T 6 IP 65 1 & 2 IIA & IIBDTD.10.08.2006 FLP/W P LAM P 75 VA

 AVIATIONREVALIDATION NOT OBSTRUCTIONREQUIRED AS TESTED LIGHTBYCM RI AS PER REVISEDBIS STANDARDS

INCREASED SAFETY LUM INAIRES

SR. ITEM CAT CM RI CERTIFICATE CM RI ADDENDUM S & SUPPLIM ENTARY

NO. NO. & DATE NOS. DATE CERTIFICATES

NOS. DATE ADDITIONS

1 BJDP/DT/TE/ISW -200 INCREASED SAFETY BJDP/DT/TE/ISW -200 CMRI/TC/P/H1335 CMRI/TC/P/H1259 23 W CFL LAM P 70 W HPSV LAMP W ITH

W ELLGLASS FITTING SUITABLE FOR INCREASED SAFETY DTD.10.11.1998 DTD.14.10.1999 BUILT IN IGNITOR LAMP HOLDER 2 PIN / 3 PIN / E 27

150 / 200 W GLS LAM P 80 / 125 W HPM V LAM P NON INTEGRAL BAKELITE / GFP / PORCELAIN CONNECTOR

160 W M LL LAM P IP 65 W ELLGLASS FITTING

2 BJISW - 80/125 INCREASED SAFETY BJISW - 80/125 CMRI/TC/P/H1455 CMRI/TC/S/H1365 23 W CFL LAMP 70 W HPSV LAMP

W ELLGLASS FITTING SUITABLE FOR INCREASED SAFETY DTD.26.11.1998 DTD.15.11.1999 W ITH OR W ITHOUT BUILT IN ADOPTOR

150 / 200 W GLS LAM P 80 / 125 W HPM V LAM P NON INTEGRAL LAM P HOLDER 2 PIN/ 3 PIN / E 27

160 W M LL LAM P IP 65 W ELLGLASS FITTING

3 BJISW - 80/125 (I) & BJISW - 250 M V (NI) BJISW - 80/125 (I) CMRI/TC/P/H1260 CMRI/TC/ADDEN/H193 BJISW - 80/125 (I) INTEGRAL & BJISW - 250 M V (NI)

INCREASED SAFETY W ELLGLASS FITTING INCREASED SAFETY DTD.14.10.1999 DTD.16.02.2000 NON INTEGRAL INCREASED SAFETYSUITABLE FOR 80/125 W /250 W HPM V LAM P INTEGRAL W ELLGLASS FITTING

70 W HPSV LAMP W ITH BUILT IN IGNITOR W ELLGLASS FITTING

70 W /150 W HPSV LAM P W ITHOUT IGNITOR IP 65

4 BJISCG - 80/125 MV INCREASED SAFETY/ W P BJISCG - 80/125 CMRI/TC/P/SL/H1454 CMRI/TC/S/H1310 (A) 70 W (B) CONNECTOR AS PORCELAIN / GFP / ELM EX

CONTROL GEAR BOX IP 65 INCREASED SAFETY DTD.26.11.1998 DTD.29.10.1999

CONTROL GEAR BOX

5 BJISCG - 250 HPM V INCREASED SAFETY BJISCG - 250 CMRI/TC/P/H1361

CONTROL GEAR BOX SUITABLE FOR INCREASED SAFETY DTD.12.11.1999

250 W HPMV / 150 W HPSV LAMP IP 65 CONTROL GEAR BOX

Page 15: Hazardous Area Lighting

8/8/2019 Hazardous Area Lighting

http://slidepdf.com/reader/full/hazardous-area-lighting 15/16

BRANCH PHONE FAX E-mail

 AHMEDABAD

106, Sakar III, Off Ashram RoadNavrangpura, Ahmedabad 380 014. 079-27543964, 27543967, 27540397 079-27543950 lum_am_ahm@ bajajelectricals.com

BANGALORE

Bajaj Bhavan, No. 16, Residency Road,

Bangalore 560 025. 080-22235486, 22238984, 22275505 080-22214878, 22275505 lum_am_ban@ bajajelectricals.com

BHUBANESW AR

Kharavela Nagar, Janpath, Bhubaneswar 751 001. 0674-2390697, 2396980, 2394052 0674-2390294 lum_am_bhu@ bajajelectricals.com

CHANDIGARH

SCO 52, Sector-26, Madhya Marg,

Chandigarh 160 026. 0172-4303211 0172-2792932 lum_am_chd@ bajajelectricals.com

CHENNAI

Navin's Presidium, 8th Floor,

 A- Block, Old No.103-A, Nelson Manickam Road,

 Aminjikarai, Chennai 600 029 044-42162200 044-42163300 lum_am_che@ bajajelectricals.com

COCHIN

CRL House, 42/1107, Tata Oil Mills Road,Cochin 682 018. 0484-2391119, 2396128, 2392039 0484-2391744 lum_am_ccn@ bajajelectricals.com

DELHI

1/10, Asaf Ali Road, New Delhi 110 002 011-23236055, 23233056, 23235057 011-23230214 lum_am_del@ bajajelectricals.com

GUW AHATI

 Agarwal House, Christian Basti,

G. S. Road, Guwahati 787 005. 0361-2346497, 2346498, 2346499 0361-2346496 lum_am_guw@ bajajelectricals.com

HARYANA

1/10, Asaf Ali Road, New Delhi 110 002 011-43725500 011-23230214 lum_am_hyr@ bajajelectricals.com

HYDERABAD

H. No. 6-3-1090/2, 3rd Floor, Vithal Das Cham bers,

Rajbhavan Road, Somaji Guda, Hyderabad 500 082. 040-23442932, 23442933, 2344293 040-23302745 lum_am_hyd@ bajajelectricals.com

INDORE

Commerce House, 3 rd Floor, 7 Race Course Road,

Indore 452 003, M P. 0731-2548909/10/18 0731-2548911 lum _am _ind@ bajajelectricals.com

JAIPURRaghukamal Niwas, M. I. Road, Jaipur 302 001. 0141-2377364, 2369541, 2369542 0141-2374261 lum_am_jai@ bajajelectricals.com

KOLKATA

10, Ganesh Chandra Avenue, Kolkata 700 013. 033-22379270, 22377657, 22216638 033-22259111 lum_am_cal@ bajajelectricals.com

LUCKNOW

Bajaj Bhavan, 21/32 A, Tilak Marg,

Lucknow 226 001. 0522-2620595, 2613549 0522-2626513 lum _am _luc@ bajajelectricals.com

MUMBAI

Harchandrai House, 3rd Floor, 81, Queens Road,

M arine Lines, M um bai 400 002. 022-22089091 022-22089193 lum _am _m um @ bajajelectricals.com

NAGPUR

2nd Floor, Saraf Court, Opp. Yashwant Stadium ,

Dhantoli, Nagpur. 0712-2440318, 2440319 0712-2420102 lum _am _war@ bajajelectricals.com

NOIDA

Flat No. 505-507, 5th Floor, Vikrant Tower,

4, Rajendra Place, Pusa Road, New Delhi 110 008. 011-25711961, 25861963, 25861964 011-25861962 lum_am_del2@ bajajelectricals.com

PATNA

Kashi Place, Dak Bunglow Road, Patna 800 001. 0612-2231427, 2220155, 2225911 0612-2231978, 2231427 lum_am_pat@ bajajelectricals.com

PUNE

Maneck Hall, 2, General Thimmayya Road,

Pune 411 001. 020-26360801, 26361321, 26360703 020-26360698 lum_am_pun@ bajajelectricals.com

RAIPUR

Bajaj Bhavan, G. E. Road,

Near Mahaveer Garden, Raipur 492 001. 0771-2263986, 2263976, 2660166 0771-2263310 lum_am_rai@ bajajelectricals.com

LUM INAIRES HEAD OFFICE and R&D OFFICE

15/17, Sant Savta m arg, Reay Road,

Mumbai 400 010. 022-2376 5000 Fax: 022-2373 0504

HEAD OFFICE

51, Mahatma Gandhi Road, Mumbai 400 001. 022-22043780, 22851462, 22875135 Fax: 022-22828250