IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Status: Date of Issue: Applicant: Electrical Apparatus: Opuonalaccessorv: Type of Protection: Marking: IECEx BAS 12.0115X Current 2015-06-09 Topworx Incorporated 3300 Fern Valley Road Louisville Kentucky 40213 United states of America series 80 GO Switch Inbinsic Safety Ex ia IIC T6IT41T3 Ga Ex ia IIiC T85°C I T135°C I T200°C Da Issue No: 2 Page 1 of 4 Certificate history: Issue NO.2 (2015-06-09) Issue NO.1 (2014-07-28) Issue No. 0 (2013-02-19) Approved for issue on behalf of the IECEx Certification Body: Position: Signature: (for printed version) Date: R. S. Sinclair Technical Manager 10 =-r' . 20\ S LUI\JE:- 1. This certificate and schedule may only be reproduced in full. 2. This certificate is not transferable and remains the property of the issuing body. 3. The Status and authenticity of this certificate may be verified by visiting the OfficiallECEx Website. Certificate issued by: SGS Baseefa Urnited Rockhead Business Park stadenLane Buxton Derbyshire SK179RZ United Kingdom
Transcript
Page 1: IECEx Certificate of Conformity - Emerson Electric...Certificate No: Date ofIssue: IECEx BAS 12.0115X 2015-06-09 'IECEx Certificate of Conformity Issue No: 2 Page 4 DETAILS OF CERTIFICATE

IECEx Certificateof Conformity

INTERNATIONAL ELECTROTECHNICAL COMMISSIONIEC Certification Scheme for Explosive Atmospheres

for rules and details of the IECEx Scheme visit www.iecex.com

Certificate No.:

Status:

Date of Issue:

Applicant:

Electrical Apparatus:

Opuonalaccessorv:

Type of Protection:

Marking:

IECEx BAS 12.0115X

Current

2015-06-09

Topworx Incorporated3300 Fern Valley Road

Louisville

Kentucky 40213

United states ofAmerica

series 80 GO Switch

Inbinsic Safety

Ex ia IIC T6IT41T3 Ga

Ex ia IIiC T85°C I T135°C I T200°C Da

Issue No: 2

Page 1 of 4

Certificate history:

Issue NO.2 (2015-06-09)

Issue NO.1 (2014-07-28)

Issue No. 0 (2013-02-19)

Approved for issue on behalf of the IECEx

Certification Body:

Position:

Signature:

(for printed version)

Date:

R. S. Sinclair

Technical Manager

10 =-r' . 20\ SLUI\JE:-

1. This certificate and schedule may only be reproduced in full.

2. This certificate is not transferable and remains the property of the issuing body.

3. The Status and authenticity of this certificate may be verified by visiting the OfficiallECEx Website.

Certificate issued by:

SGS Baseefa Urnited

Rockhead Business ParkstadenLane

BuxtonDerbyshireSK179RZ

United Kingdom

Page 2: IECEx Certificate of Conformity - Emerson Electric...Certificate No: Date ofIssue: IECEx BAS 12.0115X 2015-06-09 'IECEx Certificate of Conformity Issue No: 2 Page 4 DETAILS OF CERTIFICATE

T.l~.~.... ·..~.··~· ..~",~U

IECEx Certificateof Conformity

Certificate No:

Date of Issue:

Manufacturer:

Additional Manufacturing

location(s):

IECEx BAS 12.0115X

2015-06-09

Topworx Incorporated3300 Fern Valley Road

Louisville

Kentucky 40213

United States ofAmerica

Issue No: 2

Page 2 of 4

This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the

IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and

found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx

Scheme Rules, IECEx 02 and Operational Documents as amended.

STANDARDS:

The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was

found to comply with the following standards:

IEC 60079-0 : 2011Edition:6.0

IEC 60079-11 : 2011Edition:6.0

Explosive atmospheres - Part 0: General requirements

Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"

This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the

Standards listed above.

TEST &ASSESSMENT REPORTS:

A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in

Test Report:

GB/BAS/ExTR12.0268/00

Quality Assessment Report:

GB/SIR/QAR07.0025/05

GB/BAS/ExTR15.0138/00

Page 3: IECEx Certificate of Conformity - Emerson Electric...Certificate No: Date ofIssue: IECEx BAS 12.0115X 2015-06-09 'IECEx Certificate of Conformity Issue No: 2 Page 4 DETAILS OF CERTIFICATE

Certificate No:

Date of Issue:

IECEx BAS 12.0115X

2015-06-09

IECEx Certificateof Conformity

Issue No: 2

Page 3 of 4

SChedule

EQUIPMENT:

Equipment and systems covered by this certificate are as follows:

The Series 80 GO Switch are a range of magnetically operated switches which are actuated by the presence of an external ferrousbody. The range includes a number of different switch configurations with single pole, double throw or double pole, double throwswitches within a switch body.

The switches comprise a rectangular stainless steel or lacquered brass enclosure housing the switch mechanism sealed in the top ofthe enclosure with the sensing magnets located below. These, and the integral connections to the switch mechanism are potted in theenclosure with external connections to the switch made either by a threaded entry on the side or bottom of the switch enclosure. Theswitch is mounted in place using two mounting points that pass through the enclosure.

The switches are rated up to 30V peak a.c. or d.c., 0.25A and may be used to switch a circuit from a certified Ex ia IIC intrinsically safesource. All switch contacts within one limit switch assembly must form part of the same intrinsically safe circuit. The switched circuit iscapable of withstanding a 500V test to earth.

The Series 80 GO Switch are available with both single or double pole switch configurations, and either a side or bottom externalconnection outlet positions, all with either plug and socket or integral lead external connection options. When fitted with the integralleads, the external connections must be terminated within an enclosure provided with protection suitable for the zone of installation. Interms of intrinsic safety, all variants of the Series 80 GO Switch are identical with exception of the potting used on the 'H' hightemperature variants is suitable for the higher ambient temperature.

See Certificate Annex for details of the model range, temperature classification and input parameters.

CONDITIONS OF CERTIFICATION: YES as shown below:

1) All switch contacts within one limit switch assembly must form part of the same intrinsically safe circuit. .

2) The proximity switches do not require a connection to earth for safety purposes, but an earth connection is provided which isdirectly connected to the metallic enclosure. Normally an intrinsically safe circuit may be earthed at one point only. If the earthconnection is used, the implication of this must be fully considered in any installation, e.g. by use of a galvanically isolated interface.

3) The switch must be supplied from a certified Ex ia lie intrinsically safe source.

4) The flying leads must be terminated in a manner suitable for the zone of installation.

Page 4: IECEx Certificate of Conformity - Emerson Electric...Certificate No: Date ofIssue: IECEx BAS 12.0115X 2015-06-09 'IECEx Certificate of Conformity Issue No: 2 Page 4 DETAILS OF CERTIFICATE

Certificate No:

Date of Issue:

IECEx BAS 12.0115X

2015-06-09

'IECEx Certificateof Conformity

Issue No: 2

Page 4 of 4

DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):

Variation 2.1

To permit the Equipment name to be changed from 'Series 80 Leverless Limit Switches' to 'Series 80 GO Switch'. The EquipmentName on page 1 and the Equipment Description on Page 3 of the certificate were updated with the new name. This change does notaffect the original assessment.

Variation 2.2

To permit the addition of variants of the Series 80 GO Switch fitted with a silicone covered cable. The fitting of the silicone cable doesnot affect the input parameters or the original test and assessment of the equipment. The Certificate Annex (Issue 2) was updated tolist the new variants denoted by an'S' in the model number.

Variation 2.3

To permit the minimum ambient temperature of the 'F' marked models of the equipment to be changed from -20 to -40°C. This changedoes not affect the original assessment. The Certificate Annex (Issue 2) was updated to list the revised ambient temperature range.

ExTR: GBlBASlExTR15.0138/00

Annex:

IECEx BAS 12.0115X Annex Issue 2.pdf

File Reference: 1510189

Page 5: IECEx Certificate of Conformity - Emerson Electric...Certificate No: Date ofIssue: IECEx BAS 12.0115X 2015-06-09 'IECEx Certificate of Conformity Issue No: 2 Page 4 DETAILS OF CERTIFICATE

SGS Baseefa LimitedRockhead Business Park

Staden lane, Buxton, DerbyshireSK179RZ

United Kingdom

ANNEX to IECEx BAS 12.0115X

Series 80 GO Switch'F' & 'G' Model Range

~-

Contact Form1 =Single Pole, Double Throw2 = Double Pole, Double Throw

Outlet Position1 = Side Outlet5 = Bottom Outlet

Enclosure Material1 = Brass coated with Lacquer2 = Stainless Steel3 =Brass with corrosive resistive coating4 = Stainless Steel with corrosive resistive coating

ATEX IIECEx Certification CodeF = Zone 0, Temp. Class. T6G =Zone 0, Temp. Class T4

Input Parameters:

Issue No.2 Date: 2015/06/09

*

Custom Build Idents5 letters or numbers

Termination Options

A2 =36" PVC Covered LeadsA3 =72" PVC Covered LeadsA4 =144" PVC Covered LeadsA--- =PVC Covered Lead Lengths greater than144"

B2 =36" Rubber Covered CableB3 =72" Rubber Covered CableB4 = 144" Rubber Covered CableB--- =Rubber Covered Cable greater than 144"

F2 =36" Teflon Covered LeadsF3 = 72" Teflon Covered LeadsF4 = 144" Teflon Covered LeadsF--- =Teflon Covered Leads greater than 144"

S2 =36" Silicone Covered LeadsS3 =72" Silicone Covered LeadsS4 =144" Silicone Covered LeadsS--- =Silicone Covered Leads greater than 144"

DCD = 4 Pin Mini-Change Male ConnectorDCG = 5 Pin Mini-Change Male ConnectorDCH = 7 Pin Mini-Change Male Connector

Switch Variants with Termination Options 'OCD', 'OCG' & lOCH'

30V0.25A

oo

Switch Variants with Wiring Options 'A*', '8*', 'F*' & 'S*'

30V0.25A

33nF200IJH

Page 1 of 2

Page 6: IECEx Certificate of Conformity - Emerson Electric...Certificate No: Date ofIssue: IECEx BAS 12.0115X 2015-06-09 'IECEx Certificate of Conformity Issue No: 2 Page 4 DETAILS OF CERTIFICATE

SGS Baseefa LimitedRockhead Business Park

Staden lane, Buxton, DerbyshireSK179RZ

United Kingdom

ANNEX to IECEx BAS 12.0115X

'H' Model Range

[ill-

Contact Form1 =Single Pole, Double Throw2 = Double Pole, Double Throw

Outlet Position1 = Side Outlet5 = Bottom Outlet

Enclosure Material1 = Brass coated with Lacquer2 = Stainless Steel3 =Brass with corrosive resistive coating4 = Stainless Steel with corrosive resistive coating

ATEX IIECEx Certification CodeH = Zone 0, Temp. Class. T3

Input Parameters:

Issue No.2 Date: 2015/06/09

*

Custom Build Idents5 letters or numbers

Termination Options

F2 =36" Teflon Covered LeadsF3 =72" Teflon Covered LeadsF4 =144" Teflon Covered LeadsF--- = Teflon Covered Leads greater than 144"

S2 =36" Silicone Covered LeadsS3 =72" Silicone Covered LeadsS4 =144" Silicone Covered LeadsS--- = Silicone Covered Leads greater than 144"

30V0.25A

33nF200IJH

Model Temperature Classification

80 Series models with a 'F' as the Ex ia IIC T6 Ga (-40°C ~ Ta~ 50°C)seventh character in the model number Ex ia IIIC T85°C Da (-40°C ~ Ta~ 50°C)80 Series models with a 'G' as the ExiaIlCT4Ga(-40°C~ Ta~ 100°C)seventh character in the model number Ex ia IIIC T135°C Da (-40°C ~ Ta~ 100°C)80 Series models with a 'H' as the Ex ia IIC T3 Ga (-40°C ~ Ta~ 150°C)seventh character in the model number Ex ia IIIC T200°C Da (-40°C ~ Ta~ 150°C)

Page 2 of 2


Recommended