IECEx Certificateof Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSIONIEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com
Certificate No.:
Status:
Date of Issue:
Applicant:
Electrical Apparatus:
Opuonalaccessorv:
Type of Protection:
Marking:
IECEx BAS 12.0115X
Current
2015-06-09
Topworx Incorporated3300 Fern Valley Road
Louisville
Kentucky 40213
United states ofAmerica
series 80 GO Switch
Inbinsic Safety
Ex ia IIC T6IT41T3 Ga
Ex ia IIiC T85°C I T135°C I T200°C Da
Issue No: 2
Page 1 of 4
Certificate history:
Issue NO.2 (2015-06-09)
Issue NO.1 (2014-07-28)
Issue No. 0 (2013-02-19)
Approved for issue on behalf of the IECEx
Certification Body:
Position:
Signature:
(for printed version)
Date:
R. S. Sinclair
Technical Manager
10 =-r' . 20\ SLUI\JE:-
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the OfficiallECEx Website.
Certificate issued by:
SGS Baseefa Urnited
Rockhead Business ParkstadenLane
BuxtonDerbyshireSK179RZ
United Kingdom
T.l~.~.... ·..~.··~· ..~",~U
IECEx Certificateof Conformity
Certificate No:
Date of Issue:
Manufacturer:
Additional Manufacturing
location(s):
IECEx BAS 12.0115X
2015-06-09
Topworx Incorporated3300 Fern Valley Road
Louisville
Kentucky 40213
United States ofAmerica
Issue No: 2
Page 2 of 4
This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the
IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and
found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx
Scheme Rules, IECEx 02 and Operational Documents as amended.
STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was
found to comply with the following standards:
IEC 60079-0 : 2011Edition:6.0
IEC 60079-11 : 2011Edition:6.0
Explosive atmospheres - Part 0: General requirements
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the
Standards listed above.
TEST &ASSESSMENT REPORTS:
A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in
Test Report:
GB/BAS/ExTR12.0268/00
Quality Assessment Report:
GB/SIR/QAR07.0025/05
GB/BAS/ExTR15.0138/00
Certificate No:
Date of Issue:
IECEx BAS 12.0115X
2015-06-09
IECEx Certificateof Conformity
Issue No: 2
Page 3 of 4
SChedule
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
The Series 80 GO Switch are a range of magnetically operated switches which are actuated by the presence of an external ferrousbody. The range includes a number of different switch configurations with single pole, double throw or double pole, double throwswitches within a switch body.
The switches comprise a rectangular stainless steel or lacquered brass enclosure housing the switch mechanism sealed in the top ofthe enclosure with the sensing magnets located below. These, and the integral connections to the switch mechanism are potted in theenclosure with external connections to the switch made either by a threaded entry on the side or bottom of the switch enclosure. Theswitch is mounted in place using two mounting points that pass through the enclosure.
The switches are rated up to 30V peak a.c. or d.c., 0.25A and may be used to switch a circuit from a certified Ex ia IIC intrinsically safesource. All switch contacts within one limit switch assembly must form part of the same intrinsically safe circuit. The switched circuit iscapable of withstanding a 500V test to earth.
The Series 80 GO Switch are available with both single or double pole switch configurations, and either a side or bottom externalconnection outlet positions, all with either plug and socket or integral lead external connection options. When fitted with the integralleads, the external connections must be terminated within an enclosure provided with protection suitable for the zone of installation. Interms of intrinsic safety, all variants of the Series 80 GO Switch are identical with exception of the potting used on the 'H' hightemperature variants is suitable for the higher ambient temperature.
See Certificate Annex for details of the model range, temperature classification and input parameters.
CONDITIONS OF CERTIFICATION: YES as shown below:
1) All switch contacts within one limit switch assembly must form part of the same intrinsically safe circuit. .
2) The proximity switches do not require a connection to earth for safety purposes, but an earth connection is provided which isdirectly connected to the metallic enclosure. Normally an intrinsically safe circuit may be earthed at one point only. If the earthconnection is used, the implication of this must be fully considered in any installation, e.g. by use of a galvanically isolated interface.
3) The switch must be supplied from a certified Ex ia lie intrinsically safe source.
4) The flying leads must be terminated in a manner suitable for the zone of installation.
Certificate No:
Date of Issue:
IECEx BAS 12.0115X
2015-06-09
'IECEx Certificateof Conformity
Issue No: 2
Page 4 of 4
DETAILS OF CERTIFICATE CHANGES (for issues 1 and above):
Variation 2.1
To permit the Equipment name to be changed from 'Series 80 Leverless Limit Switches' to 'Series 80 GO Switch'. The EquipmentName on page 1 and the Equipment Description on Page 3 of the certificate were updated with the new name. This change does notaffect the original assessment.
Variation 2.2
To permit the addition of variants of the Series 80 GO Switch fitted with a silicone covered cable. The fitting of the silicone cable doesnot affect the input parameters or the original test and assessment of the equipment. The Certificate Annex (Issue 2) was updated tolist the new variants denoted by an'S' in the model number.
Variation 2.3
To permit the minimum ambient temperature of the 'F' marked models of the equipment to be changed from -20 to -40°C. This changedoes not affect the original assessment. The Certificate Annex (Issue 2) was updated to list the revised ambient temperature range.
ExTR: GBlBASlExTR15.0138/00
Annex:
IECEx BAS 12.0115X Annex Issue 2.pdf
File Reference: 1510189
SGS Baseefa LimitedRockhead Business Park
Staden lane, Buxton, DerbyshireSK179RZ
United Kingdom
ANNEX to IECEx BAS 12.0115X
Series 80 GO Switch'F' & 'G' Model Range
~-
Contact Form1 =Single Pole, Double Throw2 = Double Pole, Double Throw
Outlet Position1 = Side Outlet5 = Bottom Outlet
Enclosure Material1 = Brass coated with Lacquer2 = Stainless Steel3 =Brass with corrosive resistive coating4 = Stainless Steel with corrosive resistive coating
ATEX IIECEx Certification CodeF = Zone 0, Temp. Class. T6G =Zone 0, Temp. Class T4
Input Parameters:
Issue No.2 Date: 2015/06/09
*
Custom Build Idents5 letters or numbers
Termination Options
A2 =36" PVC Covered LeadsA3 =72" PVC Covered LeadsA4 =144" PVC Covered LeadsA--- =PVC Covered Lead Lengths greater than144"
B2 =36" Rubber Covered CableB3 =72" Rubber Covered CableB4 = 144" Rubber Covered CableB--- =Rubber Covered Cable greater than 144"
F2 =36" Teflon Covered LeadsF3 = 72" Teflon Covered LeadsF4 = 144" Teflon Covered LeadsF--- =Teflon Covered Leads greater than 144"
S2 =36" Silicone Covered LeadsS3 =72" Silicone Covered LeadsS4 =144" Silicone Covered LeadsS--- =Silicone Covered Leads greater than 144"
DCD = 4 Pin Mini-Change Male ConnectorDCG = 5 Pin Mini-Change Male ConnectorDCH = 7 Pin Mini-Change Male Connector
Switch Variants with Termination Options 'OCD', 'OCG' & lOCH'
30V0.25A
oo
Switch Variants with Wiring Options 'A*', '8*', 'F*' & 'S*'
30V0.25A
33nF200IJH
Page 1 of 2
SGS Baseefa LimitedRockhead Business Park
Staden lane, Buxton, DerbyshireSK179RZ
United Kingdom
ANNEX to IECEx BAS 12.0115X
'H' Model Range
[ill-
Contact Form1 =Single Pole, Double Throw2 = Double Pole, Double Throw
Outlet Position1 = Side Outlet5 = Bottom Outlet
Enclosure Material1 = Brass coated with Lacquer2 = Stainless Steel3 =Brass with corrosive resistive coating4 = Stainless Steel with corrosive resistive coating
ATEX IIECEx Certification CodeH = Zone 0, Temp. Class. T3
Input Parameters:
Issue No.2 Date: 2015/06/09
*
Custom Build Idents5 letters or numbers
Termination Options
F2 =36" Teflon Covered LeadsF3 =72" Teflon Covered LeadsF4 =144" Teflon Covered LeadsF--- = Teflon Covered Leads greater than 144"
S2 =36" Silicone Covered LeadsS3 =72" Silicone Covered LeadsS4 =144" Silicone Covered LeadsS--- = Silicone Covered Leads greater than 144"
30V0.25A
33nF200IJH
Model Temperature Classification
80 Series models with a 'F' as the Ex ia IIC T6 Ga (-40°C ~ Ta~ 50°C)seventh character in the model number Ex ia IIIC T85°C Da (-40°C ~ Ta~ 50°C)80 Series models with a 'G' as the ExiaIlCT4Ga(-40°C~ Ta~ 100°C)seventh character in the model number Ex ia IIIC T135°C Da (-40°C ~ Ta~ 100°C)80 Series models with a 'H' as the Ex ia IIC T3 Ga (-40°C ~ Ta~ 150°C)seventh character in the model number Ex ia IIIC T200°C Da (-40°C ~ Ta~ 150°C)
Page 2 of 2