+ All Categories
Home > Engineering > implementation of statcom and reactive power compensation

implementation of statcom and reactive power compensation

Date post: 15-Apr-2017
Category:
Upload: prashant-shekhar
View: 487 times
Download: 15 times
Share this document with a friend
37
IMPLEMENTATION OF STATCOM PROJECTEES- NISHANT SINGH KAMAL KANT YADAV PRASHANT SHEKHAR SHAILESH SINGH Project Guide :Manish Pathak
Transcript
Page 1: implementation of statcom and reactive power compensation

IMPLEMENTATION OF STATCOM

PROJECTEES- NISHANT SINGH KAMAL KANT YADAVPRASHANT SHEKHAR SHAILESH SINGHProject Guide :Manish

Pathak

Page 2: implementation of statcom and reactive power compensation

Today · changing electric power systems create a growing need for Reliability, flexibility, fast response and accuracy.

Flexible Alternating Current Transmission Systems are new devices emanating from recent innovative technologies that are maintain altering voltage phase angle

Objective

Page 3: implementation of statcom and reactive power compensation

Electrical Power

In this we are compensating the Reactive power

A. Active Power

B. Reactive Power

C. Apparent Power

Page 4: implementation of statcom and reactive power compensation

Reactive power

What is Reactive power.

Need

Importance

Purpose

Sources

Page 5: implementation of statcom and reactive power compensation

In power system, real power and reactive power is controlled by the voltage and phase angle difference between the sending end and receiving end respectively. Impedance of the transmission line can also be used to control real and reactive power. Flexible AC Transmission Systems (FACTS) are used to improve the power transfer capability of transmission line.

EXISTING SYSTEM

Page 6: implementation of statcom and reactive power compensation

THYRISTOR CONTROL REACTOR THYRISTOR SWITCHED CAPACITOR STATIC VAR COMPENSATOR THYRISTOR SWITCHED

SERIESCOMPENSATOR STATIC COMPENSATOR SELF COMMUTATED COMPENSATOR UNIFIED POWER FLOW CONTROLLER

Different fact devices

Page 7: implementation of statcom and reactive power compensation

INCREASE THE CAPABILITY OF LOADING OF LINES TO THEIR THERMAL CAPABILITES

INCREASE THE SYSTEM SECURITY THROUGH RISING THEIR TRANSIENT STABILITY LIMIT CONTROL OF POWER FLOW AS ORDERED REDUCE REACTIVE POWER FLOW

Benefits of devices

Page 8: implementation of statcom and reactive power compensation

Static synchronous compensator, is a regulating device used on ac current electricity transmission networks. It is based on a power electronics voltage-source converter and can act as either a source or sink of reactive AC power  to an electricity network. If connected to a source of power it can also provide active AC power It is a member of the FACTS family of devices.

Static Synchronous CompensatorStatcom

Page 9: implementation of statcom and reactive power compensation

Structure of Statcom

STATCOM (Static Synchronous Compensator)

Page 10: implementation of statcom and reactive power compensation

Single line diagram ofreactive power comp. using statcom

Components mainly used are :

Coupling Transformer

Voltage source converter

Capacitor bank

STATCOM controller

Page 11: implementation of statcom and reactive power compensation

OPERATING PRINCIPLE

Page 12: implementation of statcom and reactive power compensation

SIMULATION CIRCUIT

Page 13: implementation of statcom and reactive power compensation

Statcom waveform

Page 14: implementation of statcom and reactive power compensation

Svc waveform

Page 15: implementation of statcom and reactive power compensation
Page 16: implementation of statcom and reactive power compensation
Page 17: implementation of statcom and reactive power compensation
Page 18: implementation of statcom and reactive power compensation

14-Bus System without statcom

Page 19: implementation of statcom and reactive power compensation

Current and voltage Waveform(without statcom)

Page 20: implementation of statcom and reactive power compensation

14 –Bus System with statcom

Page 21: implementation of statcom and reactive power compensation

Current and voltage waveform(with statcom)

Page 22: implementation of statcom and reactive power compensation

Summary of reactive power in various buses

Page 23: implementation of statcom and reactive power compensation

Statcom in Wind Power Plant

Page 24: implementation of statcom and reactive power compensation

Statcom with PI Controller

Page 25: implementation of statcom and reactive power compensation
Page 26: implementation of statcom and reactive power compensation

Statcom with Fuzzy Logic

Page 27: implementation of statcom and reactive power compensation
Page 28: implementation of statcom and reactive power compensation

DRAWBACK OF THE PROPOSED CONTROL STRATEGY HARMONIC COMPENSATION IS NOT

ACHIEVED

PRESENCE OF FOUR PI CONTROLLERS MAKES THE SYSTEM SLOW IN RESPONSE

IT ALSO REDUSES THE STABILITY

Page 29: implementation of statcom and reactive power compensation

CONTINUOUS AND DYNAMIC VOLTAGECONTROL HIGH EFFICIENCY HIGH DYNAMIC VERY FAST RESPONSE TIME SINGLE PHASE CONTROL FOR UNBALANCED

LOADS REACTIVE POWER COMPENSATION

Main Advantages

Page 30: implementation of statcom and reactive power compensation

The static synchronous compensator (STATCOM) is increasingly popular in power system application. In general, power factor and stability of the utility system can be improved by STATCOM.

Statcom is able to provide rated current under reduced voltage condition

Why this device is used

Page 31: implementation of statcom and reactive power compensation

Voltage support and control Voltage fluctuation and flicker mitigation Unsymmetrical load balancing Power factor correction Active harmonics cancellation Improve transient stability of the power

system

Continue….!

Page 32: implementation of statcom and reactive power compensation

The STATCOM has the ability to provide more capacitive reactive power during faults, or when the system voltage drops abnormally, compared to ordinary static var compensator. This is because the maximum capacitive reactive power generated by a STATCOM decreases linearly with system voltage, while that of the SVC is proportional to the square of the voltage. Also, the STATCOM has a faster response as it has no time delay associated with thyristor firing.

Statcom vs. SVC

Page 33: implementation of statcom and reactive power compensation

33

comparison

Page 34: implementation of statcom and reactive power compensation

www.8051.in

COMPARISON OF VI CHARACTERISTICS OF SVC AND

STATCOM

Page 35: implementation of statcom and reactive power compensation

Ultra dynamic response (<10ms) No steps Ind. + cap. Capabilities Low harmonics no filters required Cheaper than SVC below §50MVAR

Characteristics of Statcom

Page 36: implementation of statcom and reactive power compensation

Future work can involve multilevel STATACOM to reduce harmonics in the system.Also more practical sophisticated method may be proposed to adress the minimization of STATCOM capacity.

STATCOM can be implemented with Predictive Controller.

Future Work

Page 37: implementation of statcom and reactive power compensation

37

25


Recommended