+ All Categories
Home > Documents > Implementing Subsea Surveillance in an Integrity … · Avocet!,PipeSim, THERMA, etc ......

Implementing Subsea Surveillance in an Integrity … · Avocet!,PipeSim, THERMA, etc ......

Date post: 17-Aug-2018
Category:
Upload: vuquynh
View: 241 times
Download: 4 times
Share this document with a friend
25
SUT Subsea UK– London - December 1st 2011 Vincent Alliot Implementing Subsea Surveillance in an Integrity Management Plan
Transcript
Page 1: Implementing Subsea Surveillance in an Integrity … · Avocet!,PipeSim, THERMA, etc ... Schlumberger valliot@slb.com. Attachments and callout slides 1. Flow meter 2. Bragg Grating

SUT Subsea UK– London - December 1st 2011Vincent Alliot

Implementing Subsea Surveillance in an Integrity Management Plan

Page 2: Implementing Subsea Surveillance in an Integrity … · Avocet!,PipeSim, THERMA, etc ... Schlumberger valliot@slb.com. Attachments and callout slides 1. Flow meter 2. Bragg Grating

Content Schlumberger subsea surveillance overview

Customer motivation towards subsea surveillance

Applications: Green and Brown fields

Technology overview: sensors, power distribution, data collection, processing, delivery and interpretation.

Value: direct and indirect

Page 3: Implementing Subsea Surveillance in an Integrity … · Avocet!,PipeSim, THERMA, etc ... Schlumberger valliot@slb.com. Attachments and callout slides 1. Flow meter 2. Bragg Grating

Distributed Fibre Optic Measurements (Temp, Vibration, Pressure, Strain)

Discrete- Multipoint Fibre Optic Measurements (Strain, Vibration, Pressure, Temp)

Integrated “data to desk” - Interpretation & Analysis DecisionSurveillance Organisation

Schlumberger Subsea Surveillance

Subsurface and Subsea monitoring data transfer & control (DH gauge, Flow Control, Pressure, Temp, Erosion, Corrosion, Production control, SSSV, +sensors, process)

Presenter
Presentation Notes
SLB Subsea Surveillance has a number of core areas including discrete and distributed Fibre optic measurement. Gauge retrofit solution is based on SMC – Subsea Monitoring and Control platform
Page 4: Implementing Subsea Surveillance in an Integrity … · Avocet!,PipeSim, THERMA, etc ... Schlumberger valliot@slb.com. Attachments and callout slides 1. Flow meter 2. Bragg Grating

Schlumberger Sensor to Customer Workflow

Subsea

High data rate, subsea network

SubseaSensors

Sensors Acquisition Network

Office

Advanced Data Analysis Tools

Offshore toOnshore Database

Historian Analyst

Platform

Offshore SCADA System

Customer Offshore Data Management

Acquisition Data Processing Secure Data

Transmission

IMMS/ICSSRTAC Local

PLM+SRS

Customer DBSLB InterAct, PRTI

SLB tools: Avocet!,PipeSim, THERMA, etc…

MRU Motion sensorssubC-collar Strain sensorsP/T Gauges

Page 5: Implementing Subsea Surveillance in an Integrity … · Avocet!,PipeSim, THERMA, etc ... Schlumberger valliot@slb.com. Attachments and callout slides 1. Flow meter 2. Bragg Grating

Customer motivations towards asset integrity surveillance Corporate management: Policy statement and

organizational implementation to preserve Company Reputation.

Discipline Experts: Knowledge capitalization to provide better support to operation and to optimize CAPEX of future field development.

Operational team: Alarms and warnings to avoid failures and to optimize OPEX.

Project Development team: manage and mitigate risks resulting from SoW added complexity

Page 6: Implementing Subsea Surveillance in an Integrity … · Avocet!,PipeSim, THERMA, etc ... Schlumberger valliot@slb.com. Attachments and callout slides 1. Flow meter 2. Bragg Grating

Application: Green Field Intimate sensor integration

to the asset Possibility to use intrusive

sensors Improved data accuracy

and reliability. Longer design life allow to

use it as safety alarm Reduced installation cost

Page 7: Implementing Subsea Surveillance in an Integrity … · Avocet!,PipeSim, THERMA, etc ... Schlumberger valliot@slb.com. Attachments and callout slides 1. Flow meter 2. Bragg Grating

Application: Brown Field Non intrusive sensor only Possible loss accuracy

due coating or additional interfaces between structure and sensor

limited mission profile Installation campaign and

demobilization.

Page 8: Implementing Subsea Surveillance in an Integrity … · Avocet!,PipeSim, THERMA, etc ... Schlumberger valliot@slb.com. Attachments and callout slides 1. Flow meter 2. Bragg Grating

Technology: choice of sensors

Understand the decision to be made and associated support information/precision required. Define the process from sensor readings to information

delivery to end user desk. Define time and spatial resolution, accuracy, precision,

expected operating life etc… Understand the environment of integration and associated

interfaces

Page 9: Implementing Subsea Surveillance in an Integrity … · Avocet!,PipeSim, THERMA, etc ... Schlumberger valliot@slb.com. Attachments and callout slides 1. Flow meter 2. Bragg Grating

Technology: sensors Strain gauges (axial, hoop and vibration) Pressure and temperature sensor Flow meter Fibre Optic (Bragg Grating or back scattering light

analysis) Corrosion, erosion, wall thickness Motion recording units (acceleration) Inclinometers, Depth sensor, Sonar, acoustic

transponders etc…

Page 10: Implementing Subsea Surveillance in an Integrity … · Avocet!,PipeSim, THERMA, etc ... Schlumberger valliot@slb.com. Attachments and callout slides 1. Flow meter 2. Bragg Grating

Technology: power distribution & data collection

DC or AC Voltage? Battery and data logger. ROV intervention. Surface umbilical (dedicated or tie-back). Fibre optic (up to 150km). Choice of an architecture and a communication

protocol: serial, power line or acoustic modems. Flying leads, junction boxes, connectors etc..

Page 11: Implementing Subsea Surveillance in an Integrity … · Avocet!,PipeSim, THERMA, etc ... Schlumberger valliot@slb.com. Attachments and callout slides 1. Flow meter 2. Bragg Grating

Technology: data processing delivery and interpretation

Reliability to cover both Structural and instrument expertise Data storage, checking and validation. Data processing from sensor raw reading into interpretable

information. Delivery to the end user: alarms, data display, reports. Subsea surveillance facilities maintenance Organization to deal with interpretation reports and

recommendation.

Page 12: Implementing Subsea Surveillance in an Integrity … · Avocet!,PipeSim, THERMA, etc ... Schlumberger valliot@slb.com. Attachments and callout slides 1. Flow meter 2. Bragg Grating

Value Return value of the system = value of the decision made with

interpreted data. Substantial gain in knowledge capitalization. Subsea Surveillance Technology may provide information not

accessible by standard maintenance plan. Example: decision to extend operating life of a subsea field

equipped with dynamic risers. Use existing architecture to extend subsea asset integrity

network to production optimization (flow assurance)

Page 13: Implementing Subsea Surveillance in an Integrity … · Avocet!,PipeSim, THERMA, etc ... Schlumberger valliot@slb.com. Attachments and callout slides 1. Flow meter 2. Bragg Grating

Contact information

Vincent Alliot Schlumberger [email protected]

Page 14: Implementing Subsea Surveillance in an Integrity … · Avocet!,PipeSim, THERMA, etc ... Schlumberger valliot@slb.com. Attachments and callout slides 1. Flow meter 2. Bragg Grating

Attachments and callout slides1. Flow meter2. Bragg Grating3. back scattering light analysis4. Choice of an architecture and a communication

protocol: serial, power line or acoustic modems.5. Data processing from sensor raw reading into

interpretable information.6. Organization to deal with interpretation reports and

recommendation.

Page 15: Implementing Subsea Surveillance in an Integrity … · Avocet!,PipeSim, THERMA, etc ... Schlumberger valliot@slb.com. Attachments and callout slides 1. Flow meter 2. Bragg Grating

1- subC-racs to monitor flexible riser annulus

Page 16: Implementing Subsea Surveillance in an Integrity … · Avocet!,PipeSim, THERMA, etc ... Schlumberger valliot@slb.com. Attachments and callout slides 1. Flow meter 2. Bragg Grating

1- subC-Racs principle

PT Gas output to flare (or vacuum pump)

WATER TRAP

Temperature measurement

Pressure and flow rate

measurementSolenoid

valve

GRV

SAMPLE / PURGE

Orifice

Presenter
Presentation Notes
When venting, the gas goes through a water trap, a high accuracy flow meter, and a solenoid valve. It can be evacuated to the flare, or via a vacuum pump, which can be advantageous in presence of H2S, to reduce the partial pressure in the annulus and lower the dew point.
Page 17: Implementing Subsea Surveillance in an Integrity … · Avocet!,PipeSim, THERMA, etc ... Schlumberger valliot@slb.com. Attachments and callout slides 1. Flow meter 2. Bragg Grating

Wavelength

Λ

Reflected Light

2- Discrete Strain Sensing Technology● FBG “written” in to fibre core

Apply strain to fibre

Refl

ecte

dlig

ht Direct Strain Measurement No Calibration Required

FBG wavelength increases linearly with applied

strain

Page 18: Implementing Subsea Surveillance in an Integrity … · Avocet!,PipeSim, THERMA, etc ... Schlumberger valliot@slb.com. Attachments and callout slides 1. Flow meter 2. Bragg Grating

Reflected light received at different timeslots

t1 t2 t3 t4 t5 t6 t7 t8

Light Source

Processor

Emitted lightfrom light source

Sensor array

Reflected light from FBGs

g1

g6

2- Discrete Strain Sensing Technology

Presenter
Presentation Notes
Time division multiplexed systems work in a different way. The light source is pulsed and sends a succession of pulses down the fibre. From each grating which are all long reflectivity can be at the same nominal wavelength a pulse is reflected. The series of pulses from each sensor arrive at the measurement unit at different times and are processed individually by very fast detection electronics. The Advantages of TDM systems are that The number of gratings not related to bandwidth of source or range of measurement so you can have many more sensing elements The gratings same wavelength and low reflectivity and so cost less as does the measurement system The disadvantages are That the detection electronics have to operate at a very high speed And the spatial resolution limited by speed of electronics which means generally that the gratings must be move than about 2m apart. Indigo actually adopted this approach though after finding a way to side step both of these limitations.
Page 19: Implementing Subsea Surveillance in an Integrity … · Avocet!,PipeSim, THERMA, etc ... Schlumberger valliot@slb.com. Attachments and callout slides 1. Flow meter 2. Bragg Grating

2- Discrete Sensing Composite Carrier● Sensors are deployed within a composite carrier to:

– Protect the optical fibre during use and handling– Optimise strain transfer – Locate sensors accurately– Provide rugged connector interface

● Geometry of carrier can take many forms

● Composite has excellent fatigue performance

Page 20: Implementing Subsea Surveillance in an Integrity … · Avocet!,PipeSim, THERMA, etc ... Schlumberger valliot@slb.com. Attachments and callout slides 1. Flow meter 2. Bragg Grating

subC-strip SURF subC-collarsubC-matsubC-rod

subC-flex

2- Discrete Strain Sensing Products

subC-pts

Presenter
Presentation Notes
Insensys IP relates to the particular implementation of fibre optic strain measurement which I will explain next, but to put this in context this diagram shows how the fibre optic is packaged in composite to suit the application
Page 21: Implementing Subsea Surveillance in an Integrity … · Avocet!,PipeSim, THERMA, etc ... Schlumberger valliot@slb.com. Attachments and callout slides 1. Flow meter 2. Bragg Grating

3- Distributed Temperature Sensing Technology

Detection of hot/cold fluid leaks

Page 22: Implementing Subsea Surveillance in an Integrity … · Avocet!,PipeSim, THERMA, etc ... Schlumberger valliot@slb.com. Attachments and callout slides 1. Flow meter 2. Bragg Grating

MV22

Fiber Optics Cable

Incident Laser Light

Backscattered Light

Laser Source

Receiver

Directional Coupler Backscattered Light(for every meter of the fibre optics)

DTS System

3- DTS Measurement Principle

ΔTNot Temperature

sensitive

Temperature sensitive

Vibration

Strain

Page 23: Implementing Subsea Surveillance in an Integrity … · Avocet!,PipeSim, THERMA, etc ... Schlumberger valliot@slb.com. Attachments and callout slides 1. Flow meter 2. Bragg Grating

4- Subsea Control / Monitoring; SURF application

ICSS

SMC SDH

Topsides HMI

P/T Sensor

P/T Sensor

P/T Sensor

P/T Sensor

SMC SDH SMC SDHsubC-Collar MRU

Page 24: Implementing Subsea Surveillance in an Integrity … · Avocet!,PipeSim, THERMA, etc ... Schlumberger valliot@slb.com. Attachments and callout slides 1. Flow meter 2. Bragg Grating

0

50

100

150

200

250

Spec

tral

den

sity

(klb

f2/ H

z)

Tension-JointTension

Average Spectral Density of Tension per Period Bin

2 to 4 sec 4 to 8 sec 8 to 16 sec 16 to 32 secPeriodBins

0

200

400

600

800

1000

1200

1400

Spec

tral

den

sity

((kl

bf.ft

)2/ H

z)

Tension-JointBending Moment

Average Spectral Density of Bending-Moment per Period Bin

2 to 4 sec 4 to 8 sec 8 to 16 sec 16 to 32 secPeriod

Bins

0

1

10

100

1,000

10,000

100,000

1,000,000

10,000,000

4.4 8.8 13.2 17.6 22.0 26.5 30.9 35.3 39.7

No.

Of C

ycle

s

Tension Range (klbf)

Tension-JointHistogram of Tension Cycles

Tension trendline

0

1

10

100

1,000

10,000

100,000

1,000,000

15 30 45 60 75 90 105 120

No.

Of C

ycle

s

Bend Moment Range (klbf.ft)

Tension-JointHistogram of Bending Moment Cycles

Bend Moment trendline

5-Data collection/processing Tension and Bending of drilling riser

Page 25: Implementing Subsea Surveillance in an Integrity … · Avocet!,PipeSim, THERMA, etc ... Schlumberger valliot@slb.com. Attachments and callout slides 1. Flow meter 2. Bragg Grating

25

6-Interpretation: fatigue damage assessment

time

Residual service life

t1 t2

100%

y%

Y%


Recommended