+ All Categories
Home > Documents > MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING...

MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING...

Date post: 28-Apr-2018
Category:
Upload: trinhthien
View: 213 times
Download: 0 times
Share this document with a friend
30
INDEX M1 ........STANDARD STORM MANHOLE ASSEMBLY A1 M2 ........STANDARD MANHOLE ASSEMBLY A2 M3 ........CONICAL MANHOLE ASSEMBLY A3 M4 ........CONICAL MANHOLE ASSEMBLY A4 M5 .........CONICAL MANHOLE ASSEMBLY A5 M6 ........CONICAL MANHOLE ASSEMBLY A6 M7 ........DOUBLE CONICAL MANHOLE ASSEMBLY A7 M8 ........REDUCING SLAB ASSEMBLY A8 M9 ........STANDARD TYPE 5 CATCHBASIN M10 ......STANDARD TYPE 6 CATCHBASIN M11 .......STANDARD SQUARE CATCHBASIN M12 ......STANDARD SLUICE BOX M13 ......VALVE CHAMBER ASSEMBLY M14 ......STANDARD SEWAGE LIFT STATION M15 ......APPLICATIONS FOR LARGE DIAMETER UNITS M16 ......STANDARD INTERNAL DROP SECTIONS M17 ......STANDARD BASE SECTIONS M18 ......STANDARD INTERMEDIATE SECTIONS M19 ......STANDARD ECCENTRIC CONES M20 ......STANDARD COVERS M21 .......CATCHBASIN COVERS M22 .......STANDARD REDUCING SLABS M23 .......STANDARD GRADE RINGS M24 .......MANHOLE TEE BASE M25 .......MANHOLE TEE BASE BEND M26 .......MANHOLE BENCHING WITH GASKETS M27 .......MAXIMUM PIPE SIZES FOR MANHOLES M28 .......SINGLE OFFSET JOINT DETAIL M29 .......STANDARD MANHOLE JOINT SEALS CONCRETE MANHOLE SPECIFICATIONS CSA SPECIFICATIONS CSA A257.3 Joints for Circular Concrete Sewer, Manholes and Culvert Pipe Using Rubber Gaskets CSA A257.4 Precast Reinforced Concrete Manhole Sections ASTM SPECIFICATIONS C478 Precast Reinforced Concrete Manhole Sections C497 Standard Methods of testing Concrete Pipe, Manhole Sections or Tile C923 Resilient Connections Between Reinforced Concrete Manhole Structures and Pipes C443 Joints for Circular Concrete Sewer and Culvert Pipe Using Rubber Gaskets C990 Joints for Concrete Pipe, Manholes and Precast Box Sections Using Preformed Flexible Joint Sealants MANHOLE INDEX
Transcript
Page 1: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

INDEX

M1 ........STANDARD STORM MANHOLE ASSEMBLY A1M2 ........STANDARD MANHOLE ASSEMBLY A2M3 ........CONICAL MANHOLE ASSEMBLY A3M4 ........CONICAL MANHOLE ASSEMBLY A4M5 .........CONICAL MANHOLE ASSEMBLY A5M6 ........CONICAL MANHOLE ASSEMBLY A6M7 ........DOUBLE CONICAL MANHOLE ASSEMBLY A7M8 ........REDUCING SLAB ASSEMBLY A8M9 ........STANDARD TYPE 5 CATCHBASINM10 ......STANDARD TYPE 6 CATCHBASINM11 .......STANDARD SQUARE CATCHBASINM12 ......STANDARD SLUICE BOXM13 ......VALVE CHAMBER ASSEMBLYM14 ......STANDARD SEWAGE LIFT STATIONM15 ......APPLICATIONS FOR LARGE DIAMETER UNITSM16 ......STANDARD INTERNAL DROP SECTIONSM17 ......STANDARD BASE SECTIONSM18 ......STANDARD INTERMEDIATE SECTIONSM19 ......STANDARD ECCENTRIC CONESM20 ......STANDARD COVERSM21 .......CATCHBASIN COVERSM22 .......STANDARD REDUCING SLABSM23 .......STANDARD GRADE RINGSM24 .......MANHOLE TEE BASEM25 .......MANHOLE TEE BASE BENDM26 .......MANHOLE BENCHING WITH GASKETSM27 .......MAXIMUM PIPE SIZES FOR MANHOLESM28 .......SINGLE OFFSET JOINT DETAILM29 .......STANDARD MANHOLE JOINT SEALS

CONCRETE MANHOLE SPECIFICATIONSCSA SPECIFICATIONS

CSA A257.3 Joints for Circular Concrete Sewer, Manholes and CulvertPipe Using Rubber Gaskets

CSA A257.4 Precast Reinforced Concrete Manhole Sections

ASTM SPECIFICATIONS C478 Precast Reinforced Concrete Manhole Sections C497 Standard Methods of testing Concrete Pipe, Manhole

Sections or Tile C923 Resilient Connections Between Reinforced Concrete Manhole Structures and Pipes C443 Joints for Circular Concrete Sewer and Culvert Pipe Using Rubber Gaskets C990 Joints for Concrete Pipe, Manholes and Precast Box Sections Using Preformed Flexible Joint Sealants

MANHOLE INDEX

Tammy
click mouse on desired subject
Page 2: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M1

SU

MP

AS

RE

QU

IRE

D

FLAT BASE

INTERMEDIATE SECTION

COVER (Offset or Center Hole As Required)

GRADE RING

CAST IRON FRAME AND COVER.

See chart page M17

See chart page M18

See chart page M20

See chart page M23

STANDARD STORM MANHOLE ASSEMBLY A11050 to 3600 mm DIAMETER42 to 144 in. DIAMETER

Page 3: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M2

GRADE RING

INTERMEDIATE SECTION

COVER (Offset or Center Hole As Required)See chart page M20

BENCHED BASE

See chart page M18

See chart page M23

CAST IRON FRAME AND GRATE.

See chart page M17

FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases shouldbe benched on site due to excessive weight of the bases.

NOTE:

STANDARD MANHOLE ASSEMBLY A21050 to 3600 mm DIAMETER42 to 144 in. DIAMETER

Page 4: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M3

ECCENTRIC CONE - EC1

BENCHED BASE - 1200mm/48 in.

INTERMEDIATE SECTION - 1200mm/48 in.

INTERMEDIATE SECTION - 1050mm/42 in.

GRADE RING

Available in 305mm/12 in. laid height increments

See chart page M23

CAST IRON FRAME AND COVER.

See chart page M18

See chart page M18Available in 305mm/12 in. laid height increments

610mm/24 in. Laid heightSee chart page M19

See chart page M17Available in 305mm/12 in. laid height increments

COVER (Center Hole As Required)See chart page M20

CONICAL MANHOLE ASSEMBLY A31200 Reduced to 1050 mm DIAMETER48 Reduced to 42 in. DIAMETER

Page 5: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M4

1219mm/48 in. laid height

See chart page M17

Available in 305mm/12 in. laid height increments

*

See chart page M23

CAST IRON FRAME AND COVER.

See chart page M18

See chart page M19

See chart page M18

Available in 305mm/12 in. laid height increments

Other section heights not recommended

305mm/12 in. laid height

*

ECCENTRIC CONE - EC2

BENCHED BASE - 1200mm/48 in.

INTERMEDIATE SECTION - 1200mm/48 in.

INTERMEDIATE SECTION - 750mm/30 in.

GRADE RING

COVER (Center Hole As Required)See chart page M20

CONICAL MANHOLE ASSEMBLY A41200 Reduced to 750 mm DIAMETER48 reduced to 30 in. DIAMETER

Page 6: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M5

915mm/36 in. laid height

See chart page M17

Available in 305mm/12 in. laid height incrementsSee chart page M18

305mm/12 in. laid height

See chart page M23

CAST IRON FRAME AND COVER.

See chart page M19

See chart page M18

Available in 305mm/12 in. laid height increments

*

* Other section heights not recommended

ECCENTRIC CONE - EC3

BENCHED BASE - 1050mm/42 in.

INTERMEDIATE SECTION - 1050mm/42 in.

INTERMEDIATE SECTION - 750mm/30 in.

GRADE RING

COVER (Center Hole As Required)See chart page M20

CONICAL MANHOLE ASSEMBLY A51050 Reduced to 750 mm DIAMETER42 reduced to 30 in. DIAMETER

Page 7: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M6

1219mm/48 in. laid height

See chart page M17

Available in 305mm/12 in. laid height incrementsSee chart page M18

305mm/12 in. laid height

See chart page M23

CAST IRON FRAME AND COVER.

See chart page M19

See chart page M18

Available in 305mm/12 in. laid height increments

Other section heights not recommended

*

*

ECCENTRIC CONE - EC4

BENCHED BASE - 1050mm/42 in.

INTERMEDIATE SECTION - 1050mm/42 in.

INTERMEDIATE SECTION - 600mm/24 in.

GRADE RING

COVER (Center Hole As Required)See chart page M20

CONICAL MANHOLE ASSEMBLY A61050 Reduced to 600 mm DIAMETER42 reduced to 24 in. DIAMETER

Page 8: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M7

610mm/24 in. laid heightSee chart page M19

See chart page M17

Available in 305mm/12 in. laid height incrementsSee chart page M18

915mm/36 in. laid heightSee chart page M19

*

See chart page M23

CAST IRON FRAME AND COVER.

See chart page M18

Available in 305mm/12 in. laid height increments

*

305mm/12 in. laid height

Other section heights not recommended

ECCENTRIC CONE - EC1

BENCHED BASE - 1200mm/48 in.

INTERMEDIATE SECTION - 1050mm/42 in.

ECCENTRIC CONE - EC3

INTERMEDIATE SECTION - 750mm/30 in.

GRADE RING

COVER (Center Hole As Required)See chart page M20

CONICAL MANHOLE ASSEMBLY A71200/48 Reduced to 750 mm / 30 in. DIAMETER

Page 9: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M8

GRADE RING

INTERMEDIATE SECTION

REDUCING SLAB

COVER (Offset or Center Hole As Required)

FLAT or BENCHED BASE

INTERMEDIATE SECTION

CAST IRON FRAME AND COVER.

See chart page M20

See chart page M23

See chart page M18

See chart page M17

See chart page M18

See chart page M22

REDUCING SLAB ASSEMBLY A8750 to 3600 mm DIAMETER30 to 144 in. DIAMETER

Page 10: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M9

kg/lbs.

MASS/WEIGHTFLAT BASE

BASE (Metric / Imperial)

HEIGHTmm/in.mm/in.

DIAMETERBASE

1524mm/60 in. laid height

305/12, 1219/48 and 1524mm/60 in. laid heightsSee chart page M18

See chart page M23

See chart page M17

118mm (4 5/8 in.)

CAST IRON FRAME AND GRATE.S

UM

P A

S R

EQ

UIR

ED

1214/2670

750/30

1219/48750/30

750/30 1464/32201524/60750/30

BASE - 750mm/30 in.

INTERMEDIATE SECTION - 750mm/30 in.

GRADE RING

COVER (Center Hole As Required)See chart page M20

STANDARD TYPE 5 CATCHBASIN750 mm DIAMETER30 in DIAMETER

Page 11: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M10

SU

MP

AS

RE

QU

IRE

D

FLAT BASE

INTERMEDIATE SECTION

COVER (Offset or Center Hole/Square Opening As Required)

GRADE RING

CAST IRON FRAME AND COVER.

See chart page M17

See chart page M18

See chart page M20 / M21

See chart page M23

STANDARD TYPE 6 CATCHBASIN1050 to 3600 mm DIAMETER42 to 144 in. DIAMETER

Page 12: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M11

TOP VIEW

610mm

24 in.

432mm

17 in.

Cast iron frameand grate.

or as

457mm18 in.

required

1758/3875

1281/2825

24 in.

610mm

61

0m

m

24

in.

127mm

5 in.

34 in.

24 in.

610mm

864mm

127mm

5 in.

17

27

mm

76

2m

m3

0 in

.

600x600/24x24

600x600/24x24

1727/68

68

in.

1219/48

kg/lbs.

MASS/WEIGHT

(Metric / Imperial)

mm/in.DIAMETER

CATCHBASIN CATCHBASIN

SQUARE CATCHBASIN

HEIGHTmm/in.

STANDARD SQUARE CATCHBASIN600 mm Square24 in. Square

Page 13: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M12

10

in.

25

4m

m

10

in.

25

4m

mGROUT AS REQUIRED

250mm/10 in. DIAMETEROPENING STANDARD

152mm

6 in.

552/1215

76

2/3

0

18 in.6 in.

610/24

30 in.

15

2m

m6

in.

152mm

450x450/18x18

45

7m

m

61

0m

m2

4 in

.

18

in.

457mm

762mm

Cast iron frameand grate.

762/30

635/1400

kg/lbs. kg/lbs.FRAME AND GRATEMASS/WEIGHT C/WFLAT BASE

HEIGHTmm/in.

SLUICE BOX

mm/in.DIAMETER

SLUICE BOX MASS/WEIGHT

(Metric / Imperial)

TOP VIEW

STANDARD SLUICE BOX750 mm Square30 in. Square

Page 14: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M13

See chart page M17

See chart page M18

See chart page M20

See chart page M23

CAST IRON FRAME AND COVER.

OPTIONAL

OPTIONAL

406mm

203m

m

406mm

508m

m

1524

mm

VALVES BY OTHERS

BASE PADS

16 in.

16 in.

8 in

.

20 in

.

60 in

.

BASE

INTERMEDIATE SECTION

COVER

GRADE RING

TOP VIEW OF BASE PADS

VALVE CHAMBER ASSEMBLY1050, 1200 and 1500 mm DIAMETER42, 48 and 60 in. DIAMETER

Page 15: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M14

ACCESS FRAME AND COVER

COVERSee page M20

See chart page M18INTERMEDIATE SECTION

(optional)

FLAT BASESee chart page M17

VARIES

GASKETCAST-IN

Mechanical and Electrical equipment to be supplied by others.

(SLOPED AS REQUIRED)CONCRETE GROUT

NOTE:

STANDARD SEWAGE LIFT STATION1200 to 3600 mm DIAMETER48 to 144 in. DIAMETER

Page 16: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M15

CONTAINMENT CHAMBER

STORMCEPTORS

TUNNELS

LIFT STATIONS

REDUCING

SECTION

FLAT BASESTANDARD

COVER

OutletInlet

STORMCEPTORSTANDARD

FLATCOVER

SECTION

HALF SECTION

FLAT BASE

FLAT COVER

HALF SECTION

SECTION

MONOBASESECTION

OPTIONAL

MECHANICALSERVICES

SECTION

APPLICATIONS FOR LARGE DIAMETER UNITS3000 to 3600 mm DIAMETER120 to 144 in. DIAMETER

Page 17: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M16

8" to

21"

51mm (2")

Standard diameter

150m

m

(6")

Min

.

51mm(2")

305 or 381mm(12" or 15")

Sta

ndar

d la

id h

eigh

t

Standard diameter

Sta

ndar

d la

id h

eigh

t

Standard pipe diameter

Standard wallthickness

Standard wallthickness

Standard wallthickness

Standard pipe diameter

203

to 5

33

NOTE: Custom sizes available upon request

INTERMEDIATE INTERNAL DROP SECTION

INTERMEDIATE INTERNAL TOP DROP SECTION

TYPICAL PLAN VIEW

FLOW

STANDARD INTERNAL DROP SECTIONS1200 and 1500 mm DIAMETER48 and 60 in. DIAMETER

Page 18: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M17

THICKNESSWALL

HEIGHTFLAT BASE

MASS/WEIGHT

mm/in.mm/in.kg/lbs.

HEIGHTLAID

THICKNESSBASE SLAB

mm/in.

MASS/WEIGHT

BASES

MANHOLEDIAMETER BASE HEIGHT

BENCHED

mm/in. mm/in. kg/lbs.

114/4.5

127/5

178/7

152/6

1219/48

915/36

610/24

305/12

915/36

610/24

1524/60

1219/48

305/12

1524/60

1219/48

610/24

915/36

305/12

915/36

1219/48

1524/60

610/24

1829/72

305/12

3500/7715

4112/9065

2379/5245

5826/12845

4965/10945

4103/9045

3241/7145

1724/3800

780/1720

1107/2440

1433/3160

959/2115

1388/3060

1810/3990

2275/5015

1662/3665

2620/5775

2204/4860

2887/6365

4724/10415

203/8

203/8

152/6

152/6

229/9

203/8

298/11.75

330/13

1219/48

305/12

610/24

915/36

1829/72

1219/48

915/36

610/24

305/12

2438/96

2438/96

610/24

1219/48

915/36

305/12

305/12

1219/48

915/36

610/24

2438/96

8482/18700

6591/14530

4128/9100

5579/12300

7031/15500

5457/12030

4323/9530

3189/7030

6688/14745

14288/31500

15681/34570

8537/18820

10918/24070

13300/29320

25207/55570

21399/47175

11941/26325

15094/33275

18246/40225

11127/24530

34009/749752438/96

203/8

203/8

305/12

305/12

1194/2632

1361/3000

1696/3740

1819/4010

2023/4460

3506/7730

2944/6490

2381/5250

---

----

8245/18176

7330/16160

5988/13200

5443/12000

4581/10100

3974/8760

----

----

----

3107/6850

---

1050/42

1200/48

---

---

---

---

1500/60

1800/72

457/18

610/24

915/36

1219/48

610/24

915/36

1219/48

1524/60

1829/72

1524/60

1829/72

1524/60

1219/48

915/36

610/24

----

8573/18900

9798/21600

12247/27000

10977/24200

15060/33200

9616/21200

13608/30000

12338/27200

----

----

----

----

----

----

----

----

----

----

----

---

---

2100/84

2400/96

---

---

---

---

---

---

---

---

---

---

3000/120

3600/144

1829/72

1524/60

1219/48

1219/48

2438/96

1524/60

2438/96

1829/72

-------

(metric/imperial)

STANDARD BASE SECTIONS1050 to 3600 mm DIAMETER42 to 144 in. DIAMETER

Page 19: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M18

SIZES AVAILABLE

SIZES AVAILABLE

114

114

114

152

127

203

177

446

774

1071

1361

2008

2828

3720

229

298

330

4.5

4.5

4.5

5

6

7

8

9

13

11.75

4762

7813

10343

3200

2500

1900

1350

915

720

520

300

5250

6950

600

750

1050

1800

1200

1500

2100

2400

3000

3600

24

30

42

48

60

72

84

96

120

144

WALLMASS

LAIDHEIGHT

kg/m2134 2438 THICKNESS

WALLlbs./footWEIGHT

9684 THICKNESS

HEIGHTS

(Metric) mm

15241219915305 610

SECTIONDIAMETER

6048

(Imperial) in.

HEIGHTS

3612 24

SECTIONDIAMETER

1829

72

INTERMEDIATE SECTIONS

INTERMEDIATE SECTIONS

STANDARD INTERMEDIATE SECTIONS600 to 3600 mm DIAMETER24 to 144 in. DIAMETER

Page 20: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M19

WALLL

AID

HE

IGH

T

816

1542

610

114

4.5

816

1088

1088

915

1800

2400

1800

3400

24

36

48

48

240048

1200 to 750

1200 to 1050

EC2

EC1

1050 to 750

1050 to 750

1050 to 600

42 to 30

42 to 30

48 to 30

48 to 42

EC3

EC4

EC1

EC3

EC2

42 to 24EC4

1219

1219

1219

THICKNESSWALL

kgMASS

THICKNESSWALL

lbs.WEIGHT

CONEDIAMETERTYPE

CONE

DIAMETERCONECONE

TYPELAID HT.

LAID HT.

(Imperial) in.

(Metric) mmECCENTRIC CONES

ECCENTRIC CONES

STANDARD ECCENTRIC CONES

Page 21: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M20

203/8

203/8

203/8

204/8

152/6

152/6

152/6

305/12

152/6

454/1000

616/1358

1302/2870

1930/4254

3502/7720

2650/5840

113/250

209/460

8321/18345

305/12 11587/25545

LAIDHEIGHT

330/13

267/10.5

267/10.5

324/12.75

330/13

330/13

242/9.5

457/18

242/9.5

2100/84

1800/72

1500/60

1200/48

1050/42

2400/96

750/30

600/24

3000/120

457/183600/144

Special sizes upon request

600mm/24 in.675mm/27 in.750mm/30 in.

OTHER LOCATIONS FOR HOLES AVAILABLE BY REQUEST.STANDARD ACCESS HOLE PATTERNS AS SHOWN ABOVE.

The weights provided are calculated using a 600mm diameter opening.

RECESS OPTIONAL

thicknessCover

OPENING DIAMETERAS REQUIRED

CENTERED OPENING

COVERTHICKNESS

mm/in.

MASS/WEIGHTkg/lbs.

AS REQUIREDOPENING DIAMETER

OFFSET OPENING

LAID HEIGHT

mm/in.

COVERDIAMETER

mm/in.

NOTES:

(Metric / Imperial)COVERS

TOP VIEW

STANDARD OPENINGS:

216/8.5 264/580300/12 750/30

216/8.5 143/315 600/24 300/12

190/7.5 518/1143300/121050/42

190/7.5 704/1552300/121200/48

STANDARD COVERS600 to 3600 mm DIAMETER24 to 144 in. DIAMETER

Page 22: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M21

La

id h

eig

ht

Co

ver

thic

kne

ss

La

id h

eig

ht

by request.

1302/2870

1930/4254

589/1300

616/1358

1930/4254

1302/2870

616/1358

454/1000

1143/2520

above. Other locationspatterns as shown

for holes available

Standard access hole

Co

ver

thic

kne

ss

La

id h

eig

ht

Co

ver

thic

kne

ss

1500/60

1200/48

1050/42

1800/72

1800/72

1500/60

1200/48

1050/42

330/13

267/10.5

267/10.5

324/12.75

330/13

324/12.75

267/10.5

267/10.5

572/22.51050/42

2

2

2

2

1

1

1

1

1

Special sizes upon request

The weights provided are calculated using a 600mm square opening.

203/8

203/8

152/6

152/6

203/8

203/8

152/6

152/6

457/18

OPENING600mm/24" SQUARE

CENTERED OPENING

MASS/WEIGHT

kg/lbs.

CENTERED OPENING

OFFSET OPENING

TWIN 600mm/24"SQUARE OPENING

LAID HEIGHT

(Metric / Imperial)

COVERDIAMETER

mm/in. mm/in.OPENINGS

NUMBEROF

NOTES:

COVERTHICKNESS

mm/in.

COVERS

TOP VIEW

CATCH BASIN COVERS1050 to 1800 mm DIAMETER42 to 72 in. DIAMETER

Page 23: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M22

SLA

B

WALL

LAID

HE

IGH

T

5.00

4.50

7.00

6.00

6.00

6.00

127

114

152

152

152

179

6.0

6.0

8.0

12.0

12.0

12.0

152

152

305

305

203

305

1000

1358

2870

3375

2925

5000

8.00

8.00

8.00

7.00

9.00

9.00

9.00

9.00

11.75

11.75

11.75

11.75

13.00

13.00

13.00

13.00

179

203

203

203

229

229

229

229

12.0

12.0

12.0

12.0

12.0

12.0

12.0

12.0

298

298

298

298

330

330

330

12.0

12.0

12.0

12.0

12.0

12.0

12.0

305

305

305

305

305

305

305

305

5400

6355

7720

7320

7870

9040

10405

10005

305

305

305

305

305

305

305

14975

17110

17510

11950

24310

22175

19150

12.024710 305 330

10.50

10.50

16.75

16.75

12.75

17.00

48 to 30

42 to 30

72 to 48

60 to 48

60 to 42

60 to 30

432

324

425

425

267

267

1800 to 1200

1200 to 750

1500 to 1200

1500 to 1050

1500 to 750

1050 to 750

17.00

17.00

17.00

17.00

17.00

17.00

17.00

17.00

17.00

18.00

18.00

17.00

18.00

18.00

18.00

84 to 48

84 to 42

84 to 60

72 to 42

96 to 72

96 to 60

96 to 48

96 to 42

120 to 96

120 to 42

144 to 96

120 to 48

120 to 72

144 to 48

144 to 72

432

432

432

432

432

457

457

457

432

457

457

432

432

432

432

457144 to 42 18.00

2400 to 1800

2400 to 1500

2400 to 1200

3000 to 2400

2400 to 1050

3000 to 1050

3600 to 2400

3000 to 1200

3000 to 1800

3600 to 1050

3600 to 1200

3600 to 1800

2100 to 1200

2100 to 1050

2100 to 1500

1800 to 1050

4100

3570

4538

5420

4720

8686

7942

7761

6793

11208

10058

11027

3320

3502

2883

2450

2268

616

1327

1531

1302

454

WALL

ImperialMetricImperialLbsTHICKNESS

SLAB

MetricTHICKNESS

Imperial

LAID HT.SLAB

Imperial MetricMetricDIAMETER

(Metric / Imperial) mm / in.

MASS/WEIGHT

Kg

REDUCING SLABS

STANDARD REDUCING SLABS750 to 3600 mm DIAMETER30 to 144 in. DIAMETER

Page 24: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M23

34

204

102

113

57

52

170

227

64

127

170

227

113

114

114

114

114

114

114

50

152

305

76

152

76

114

114

114

114

114

114

114

229

305

76

152

229

305

152

838

915

915

838

838

838

675

600

991

991

915

915

750

Nova Scotia only

838 x 838

838 x 838

838 x 838

75

115

450

225

250

375

140

500

280

250

500

375

125

4.5

4.5

4.5

4.5

2

3

12

6

4.5

4.5

4.5

4.5

4.5

4.5

4.5

4.5

6

9

3

12

6

6

12

9

4.5 3

33

33

33

3324

36

36

36

39

39

27

30

36

33 x 33

33 x 33

33 x 33

750mm/30 in.

600mm/24 in.

675mm/27 in.

B

A

B

A

610 x 610 / 24" x 24"

610 x 610

24 x 24

kgMASS

BALAID HT.OUTSIDE

DIAMETER

(Metric) mm

WALL THK.

lbs.WEIGHT

BALAID HT.

(Imperial) in.

OUTSIDEDIAMETER

WALL THK.

*

*

STANDARD OPENINGS

*

STANDARD OPENING

GRADE RINGDIA. / SIZE

GRADE RINGDIA. / SIZE

TOP VIEW

ROUND GRADE RINGS

SQUARE GRADE RINGS

GRADE RINGS

GRADE RINGS

New Brunswick only+

***

***

+ 154152152991

***

Nova Scotia only* New Brunswick only+

***

+ 3406639

STANDARD GRADE RINGS600 to 750 mm DIAMETER and 610 x 610 mm SQUARE24 to 30 in. DIAMETER and 24 x 24 in. SQUARE

Page 25: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M24

96 in.

7.5

in.

19

1m

m

6 in

.

15

2m

m

BASE

OPTIONALSUPPORT

SINGLEOFFSETJOINT

1397 or 1575mm SQUARE

AS REQUIRED

2438mm

42 or 48 in. SHAFTING1050 or 1200mm SHAFTING

750 to 3600mm

See manhole assembly chart page M17

30 to 144 in.

55 or 62 in. SQUARE

NOTE:

TOP VIEW

MANHOLE TEE BASE750 to 3600 mm DIAMETER30 to 144 in. DIAMETER

Page 26: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M25

NOTE:

1050 or 1200mm SHAFTING42 or 48 in. SHAFTING

102mm MINIMUM

AS REQUIRED

750 to 3600mm

SINGLEOFFSETJOINT

152m

m19

1mm

OPTIONALSUPPORTBASE

See manhole assembly chart page M17

30 to 144 in.4 in. MINIMUM

6 in

.7.

5 in

.

TOP VIEW

MANHOLE TEE BASE BEND750 to 3600 mm DIAMETER30 to 144 mm DIAMETER

Page 27: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M26

PVCT-JUNCTION

PVC180 /DEAD END

PVC90 BEND

LAID HEIGHToo

(Metric / Imperial)

DIAMETERMANHOLE

mm/in. mm/in. mm/in. mm/in. mm/in.

BENCHING

SINGLE OFFSET JOINT

CAST-IN GASKET

BENCHING

610m

m (

24 in

.)

1219

mm

(48

in.)

2% GRADE ACROSS MANHOLE

203/8 203/8 203/8

1050/42 -- 254/10 254/10

305/12305/12 --

-- -- 305/12

254/10 -- --

1200/48

203/8 -- --

457/18

381/15

-- --

-- -- 915/36 and

915/36 and

610/24 and

610/24 and

610/24 and

610/24

610/24

610/24

1219/48

1219/48

1219/48

1219/48

1219/48

T-JUNCTION

90 BEND

180 or

o

DEAD END

oNOTE:

BENCHING

MANHOLE BENCHING WITH GASKETSStandard configurations - Available from stock

Page 28: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M27

MANHOLEDIAMETER

1050 / 42

1200 / 48

1500 / 60

1800 / 72

2100 / 84

2400 / 96

3000 / 120

3600 / 144

1050 / 42&

1200 / 48&

1500 / 60

MAX. PIPE SIZE C/WG-LOCK GASKET

MIN. ANGLEBETWEEN PIPE

MAX. ROUGHCUT ACCESS

MIN. ANGLEBETWEEN PIPE

MIN. BASEHEIGHT

CONCRETE PIPE

PVC \ DUCTILE IRON (DI) PIPE

1200 / 48900 / 36750 / 30750 / 301500 / 601200 / 481200 / 481800 / 721500 / 601200 / 481800 / 721500 / 601500 / 602100 / 841800 / 721800 / 722400 / 962100 / 841800 / 722400 / 962400 / 962100 / 842400 / 962400 / 962100 / 84

533 / 21457 / 18381 / 15305 / 12762 / 30610 / 24533 / 21915 / 36762 / 30610 / 24

1067 / 42915 / 36762 / 30

1219 / 481067 / 42915 / 36

1524 / 60 (SO)1219 / 481067 / 42

1829 / 72 (SO)1524 / 60 (S0)

1219 / 481829 / 72 (SO)1524 / 60 (SO)

1219 / 48

457 / 18533 / 21610 / 24

ECONO GASKET102 / 4152 / 6203 / 8254/ 10305 / 12

356 / 14 (DI)381 / 15

724 / 28.5635 / 25

546 / 21.5457 / 18991 / 39813 / 32

724 / 28.51168 / 46991 / 39813 / 32

1346 / 531168 / 46991 / 39

1524 / 601346 / 531168 / 461880 / 741524 / 601346 / 532235 / 881880 / 741524 / 602235 / 881880 / 741524 / 60

- (SO) designates special order units

* The minimum concrete required between pipe openings in all directions = 150mm / 6 in.- See page M17 for base units, M18 for intermediate sections and page M26 for benching and gaskets.

IN

OUT

150mm

6" min.150

mm

6" m

in.

MIN. ANGLE

BETWEEN PIPE

BASE or SECTION

150

mm

6" m

in.

150

mm

6" m

in.

8090

100

35455055606570

521 / 20.5610 / 24686 / 27

152 / 6216 / 8.5267 /10.5318 /12.5368 /14.5432 /17

445 /17.5

8090

100

35455055606570

900 / 361200 / 481200 / 48

600 / 24600 / 24600 / 24600 / 24600 / 24600 / 24750 / 30

105908070

125100901159580

1059075

10090751109075

1058570857055

100857565

12095851109075

1008570958570

1058570

1008065806550

MAXIMUM PIPE SIZES FOR MANHOLES1050 to 3600 mm DIAMETER42 to 144 in. DIAMETER

Page 29: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M28

CAST IRON FRAMEAND COVER.

EC2, EC3 AND EC4ECCENTRIC CONES

INTERMEDIATE SECTION

INTERMEDIATE SECTION

COVER

GRADE RING

SEE JOINT SEALS PAGE M29

SINGLE OFFSET JOINT DETAIL600 / 24 and 750 mm / 30 in. DIAMETER

Page 30: MANHOLE INDEX click mouse on desired subject€¦ · A257.3 , Manholes and Culvert ... FOR LIFTING PURPOSES - 3000mm/120" and 3600mm/144" bases should be benched on site due to excessive

M29

NOTES:

1) The BELL and SPIGOT must be cleaned andlubricated, if required, prior to assembling each unit.

2) The SINGLE OFFSET GASKET must be placed as permanufacturer’s recommendations around the spigotend of the pipe. The gasket must be placed tight to thespigot shoulder. (See pages P11 and P12)

3) Each unit must be placed squarely on top of the otherto prevent the gasket from unseating itself anddamaging the unit.

NOTE: From time to time we may have to revert back to our old gasket system to meet supply anddemand conditions (see page P13).

SINGLEOFFSETGASKET

BUTYLSEALANT

SINGLEOFFSETGASKET

AND BUTYLSEALANT

CONFINED "O"-RINGDETAIL

STANDARD MANHOLE JOINT SEALSManholes, sewage lift stations, catchbasins and valve chambers


Recommended