+ All Categories
Home > Documents > MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More...

MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More...

Date post: 08-Jun-2018
Category:
Upload: hoangcong
View: 220 times
Download: 1 times
Share this document with a friend
43
MEDICAL OIL-FREE COMPRESSORS
Transcript
Page 1: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

MEDICAL OIL-FREE COMPRESSORS

Page 2: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

COMMITTED TO SUSTAINABLE PRODUCTIVITY

We stand by our responsibilities towards our customers, towards the environment and the people around us.We make performance stand a test of time. This is what we call – Sustainable Productivity.

Page 3: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

ROAD TO OIL-FREE

Finish – the oil-free medical world !

Start

Page 4: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

ROAD TO OIL-FREE

Today – Oil injected technology

What is the difference withan industrial compressor?

What are the specific features of each technology? What will be the price?

How to order?

Finish – the oil-free medical world !

Which technologies can we offer?

Page 5: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

Two ideologies:

1. HTM/ISO – take in ambient air, use any type of air compression method (oil-injected or oil-free) and ensure patient safety by means of an ultra high purification system (MED + QDT)

2. NFPA99 (US) / CSA 7396-1 (CAN) – be more stringent on air quality intake and ensure patient safety by not adding contaminants during the air compression stage

In normal operation both systems will provide clean air, however only oil-free solutions fullyeliminate the risk of oil carry-over to the patient

CLEAN AIR IS A MUST FOR PATIENT SAFETY

Page 6: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

ROAD TO OIL-FREE

Page 7: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

ROAD TO OIL-FREE

Today – Oil injected technology Why use oil-free in medical?

What is the difference withan industrial compressor?

What are the specific features of each technology? What will be the price?

How to order?

Finish – the oil-free medical world !

Which technologies can we offer?

Page 8: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

TODAY – OIL-INJECTED AIRPLANTS

� Proven technology

� Using Atlas Copco’s premium range of oil-injected rotary screw compressors

� Adapted for use in medical Airplants

� Incorporating Mk5 Elektronikon graphic controller

� Airplants complying to HTM & ISO requirements

GA-MED

Page 9: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

OIL-FREE, CONTAMINANT FREE… RISK FREE

WHAT'S WRONG WITH OIL IN AIR ?

2-3 mg/m³ = 5 LITERS / YEAR

Page 10: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

1)UNDER-USAGE

� ISO7396-1 (HTM02-01 for UK) requires 3 redundant compressors

� The design flow is often hugely oversized !

� The addition of terminal units in areas with low usage or occupancy adds a need for additional flow capacity which is seldom needed – think of medical air in ward areas for example

� All this under-usage leads to creation of condensation & blockages downstream.

HOW OFTEN DO YOU SEE THESE IN USE?

Sometimes?

Often?

Occasionally?

ALMOST NEVER...

Solutions? Oil-free (or VSD)

A tangible threat in medical

Emulsification

Page 11: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

1)UNDER-USAGE

� Other applications vulnerable to under-usage:– Teaching facilities

– Military facilities

– Laboratories or R&D facilities

– Sterilisation facilities

� Other causes of under-usage:– Oversizing for future expansion of a hospital

� adds up to 25% on top of an already oversized system

A tangible threat in medical

IF THE AIRPLANT IS SIGNIFICANTLY UNDER-USED

OIL-FREE (OR VSD) ELIMINATES THE RISK !

Page 12: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

2)OIL CARRY OVER

� ISO7396-1 (HTM02-01 for UK) requires 2 redundant Air treatment devices (MED)

� Performance stated at 20°C !

� What happens in real life ?

A tangible threat in medical

Page 13: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

CONSEQUENCES OF OIL

A failure of any of the air treatment components could cause:– Risk to patient health

– Require complete rebuilding of hospital pipelines

– Damage to expensive equipment (e.g. anesthesia machine)

Page 14: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

3) LACK OF MAINTENANCE

� Although oil carry-over happens in medical systems, generally this does not cause harm to patients

� More likely the problem is contamination of components

Saturated filters are often the route cause !

� This is often a problem with maintenance (OR LACK OF)! In particular this is a problem where there is little or no dedication to preventive or routine maintenance .

Causing damage to dryer components

Page 15: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

3)LACK OF MAINTENANCE

� Does this sound familiar in your facility?

– If it does then oil-free solutions offer complete piece of mind

– By eliminating the risk of oil damaging the purification system

= TOTAL PATIENT SAFETY

Causing damage to Air treatment components

Page 16: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

ROAD TO OIL-FREE

Today – Oil injected technology Why use oil-free in medical?

What is the difference withan industrial compressor?

What are the specific features of each technology? What will be the price?

How to order?

Finish – the oil-free medical world !

Which technologies can we offer?

Page 17: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

ATLAS COPCO IS A…

� Active in oil-free for more than 60 years

� We have installed > 40,000 oil-free machines World wide

� We are The First manufacturer to receive ISO 8573-1 CLASS 0 certificate

� We offer the widest range of pressures (up to 13 bar - AQ) and FAD (2 l/s - 155 l/s), using 3 different technologies to produce 100% oil-free air: piston - tooth - water injected screw

Global market Leader in oil-free technology

Page 18: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

ENVIRONMENTAL FRIENDLY

� FACT – The removal of waste oil is expensive, difficult to handle and an environmental hazard

� Local regulations oblige additionalinvestments to remove and treatcontaminated condensate.

Page 19: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

CONCLUSION – THE ADVANTAGES OF OIL-FREE AIRPLANTS

� No risk of oil carry-over

� No risk of damaged dryer components

� No emulsification

� More environmental friendly

� Higher customer value

Clean air is a choice you make – choose oil free

Oil-free, contaminant free… risk free

Page 20: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

ROAD TO OIL-FREE

Today – Oil injected technology Why use oil-free in medical?

What are the specific features of each technology? What will be the price?

How to order?

Finish – the oil-free medical world !

Which technologies can we offer?

Page 21: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

ROAD TO OIL-FREE

Page 22: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

OIL-FREE MEDICAL COMPRESSORS

� We use different technologies to match customer’s needs:

COMMON MEDICAL RANGE

*

Application window

Page 23: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

ROAD TO OIL-FREE

Today – Oil injected technology Why use oil-free in medical?

What are the specific features of each technology? What will be the price?

How to order?

Finish – the oil-free medical world !

Which technologies can we offer?

What is the difference withan industrial compressor?

Page 24: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

LEGAL REQUIREMENTS FOR MEDICAL COMPRESSORS

� Due to the compressor being considered part of a Medical Device (Medical Airplant), it should:– Have a risk analysis

– Software should be compliant with EN62304 (class A)� Software should be extensively tested acc. to standard

� Test report should be created and available on request

� EMC test performed (Domestic/industrial Environment !)

– Be part of technical file (MDMF) for a Medical Airplant

– Have automatic-restart-after-power-failure activated

– Additional safety features based on Risk Analysis

– Specific test procedures during design, production, installation and commissioning

– Tested as a complete package – Medical Airplant

Medical Device Directive 93/42/EEC ISO

HTM

Page 25: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

LEGAL REQUIREMENTS FOR MEDICAL COMPRESSORS

� General functions of compressors:– individual starter units

– an isolator interlocked with the covers

– an industrial grade ampmeter

– a “total hours” counter

� Control functions (communicated to hospital via alarms):– control circuit failed

– motor tripped

– aftercooler temperature high

– compressor temperature high

– compressor failed-to-go-on-load

– activation of other safety devices supplied by the manufacturers

HTM 02-01, HTM2022 – items in addition to ISO7396-1

Page 26: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

INDUSTRIAL OR MEDICAL EQUIPMENTIt is all about human beings

Page 27: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

OIL-FREE PLANT BASED ON PISTON TECHNOLOGYLF-MED

Page 28: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

LF-MED PRODUCT RANGE

� LF-MED*– Single-stage oil-free reciprocating compressors

designed for operating at maximum working conditions

– Available in 3 power ratings: 5, 7 & 10 kW

– Pressure of 10 bar (145 psi) and capacities from 3.1 to 15.5 l/s at 50 Hz, 7.6 to 38.6 cfm at 60 Hz

– Scope of supply: Power Pack (PP)� Compressor block, transmission & motor

* LE-MED (oil-lubricated piston technology) also available

Page 29: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

LF-MED MAIN ADVANTAGES

� Based on a durable, high performance LF-compressor

� Always uses Y-D control for easy & fast start

� Supplied with advanced control system (Mk5 Elekronikon Graphic), including:– Full integration with ES-MED Central Controller– Easy service and diagnosis

� Includes medical safety features, like:– Full remote monitor/control– Automatic restart after voltage failure (ARAVF)

– Emergency Forced Local (EFL)– Additional outlet temperature & FTGOL monitor

� Complies to the compressor requirements of medical standards:– HTM 02-01 & HTM 2022– ISO 7396-1– EN 62304 (Class A software device)

Page 30: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

OIL-FREE PLANT BASED ON TOOTH TECHNOLOGYZT-MED & ZR-MED

Page 31: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

ZT/ZR-MED RANGE

Features:

� Medical software and reliability

� Combined inlet silencer & filter

� Workplace - Reduced noise level

� Vertical cooler set-up with integrated WSD

� Electronic Water Drain

� Environmental friendly– No risk of oil contamination

� Variable Speed Drive (VSD) available– Best energy saver

Page 32: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

TECHNICAL SPECIFICATION: ZT-MED & ZR -MED PLANT

� ISO version: ZT15-ZT55 VSD (15-55 kW)

� Voltage variants: 400 V 50Hz

� Air and Water cooled (ZT/ZR)

0,020,040,060,080,0

100,0120,0140,0160,0180,0

1(+

2) x

ZT

15 M

ED

1(+

2) x

ZT

18 M

ED

1(+

2) x

ZT

22 M

ED

2(+

2) x

ZT

15 M

ED

2(+

2) x

ZT

18 M

ED

2(+

2) x

ZT

22 M

ED

3(+

2) x

ZT

15 M

ED

3(+

2) x

ZT

18 M

ED

4(+

2) x

ZT

15 M

ED

3(+

2) x

ZT

22 M

ED

4(+

2) x

ZT

18 M

ED

4(+

2) x

ZT

22 M

ED

uAIR – Max delivery by plant, l/s (2 back-up compress ors; ISO7396-1)

Page 33: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

OIL-FREE PLANT BASED ON WATER INJECTED COMPRESSORSAQ-MED

ONLY ISO !

Page 34: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

AQ-MED VSD – THE BEST COMBINATION

� The premium solution AQ-MED VSD – Energy savings

– Medical software and reliability

– Environmental friendly

– Stable pressure band

– Progressive start� No intensity peaks

� Increases element reliability

� Advanced design– No oil

– No lipseals

– No gearbox

Maximizing efficiency, saving energy

Page 35: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

ROAD TO OIL-FREE

Today – Oil injected technology Why use oil-free in medical?

What are the specific features of each technology? What will be the price?

How to order?

Finish – the oil-free medical world !

Which technologies can we offer?

What is the difference withan industrial compressor?

Page 36: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

SELECTION MATRIX OF OIL-FREE TECHNOLOGY

Matrix gives a basic information and comparison. Te chnology is overlapping. In most applications multiple choices are available .

Piston: LF-MED

Scroll:SF-MED*

Water-lubricated: AQ-MED

Tooth:ZT-MED

Flow of plant, l/s (l/m) 1 or 2 backups

0 – 530 - 3.180

5 –30(44)300 – 1.630(2.400)

22 – 2821.320 – 16.920

25 - 1541.500 – 9.240

Pros • Simple to service• Vessel mounted

version available• Suitable for remote

location• Compact• Lowest capital cost

• Very silent• Compact design• All elements

controlled individually giving high efficiency and savings

• VSD technology as standard

• Pressure up to 13 bar• Efficient cooling

• High efficiency at large flows

• Most efficient cost/flow

Cons • Recommend to use sound hound to reduce noise emission

• Efficiency

• Max ambient air +45°C

• Low pressure for combined med air systems

• Not for HTM02-01 • Large dimensions

• Highest capital cost

Page 37: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

ROAD TO OIL-FREE

Today – Oil injected technology Why use oil-free in medical?

What are the specific features of each technology? What will be the price?

Finish – the oil-free medical world !

Which technologies can we offer?

What is the difference withan industrial compressor?

Page 38: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

WHAT ABOUT CUSTOMER VALUE? SEE THE FULL PICTURE

Investment

Disposal (filters, oil)Risk of contamination

Risk of damage to expensive equipment

Oil treatment (OSC)

Risk of additional repairs

Oil-injected Oil-free

CUSTOMER VALUE

Page 39: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

OIL FREE – A UNIQUE PROPOSAL

� Medical airplants based on best-in-class oil-free compressors– No chance of oil

� Full compliance with requirements of medical standards– Peace of mind

� All equipment complies with EN 62304– Lock-out spec

� 4 oil-free compressor technologies are possible– Unique proposition

� Higher customer value

Page 40: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

THE OIL-FREE WORLDQuality, Reliability, Safety

Clean air is a choice you make – choose oil free

Oil-free, contaminant free… risk free

Page 41: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

ROAD TO OIL-FREE

Today – Oil injected technology Why use oil-free in medical?

What is the difference withan industrial compressor?

What are the specific features of each technology? What will be the price?

How to order?

Finish – the oil-free medical world !

Which technologies can we offer?

Page 42: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

COMMITTED TO

SUSTAINABLE PRODUCTIVITY.

Page 43: MEDICAL OIL-FREE COMPRESSORSuuid:... · Incorporating Mk5 Elektronikon graphic controller ... More likely the problem is contamination of ... – Full remote monitor/control – …

Recommended