Table of ContentsA. MILLENIUM SOFTWARE.....................................................................................................................................1

Millennium Expert.....................................................................................................................................3Millennium Enterprise...............................................................................................................................4Millennium Xtra.........................................................................................................................................5

B. MILLENNIUM HARDWARE.................................................................................................................................7Door Control Device (DCD)........................................................................................................................8Site Control Unit (SCU)..............................................................................................................................9

Elevator Control Unit (ECU).....................................................................................................................12Elevator Control Device (ECD).................................................................................................................13Relay Control Device (RCD).....................................................................................................................14Millenium Site Ethernet Interface (SEI)...................................................................................................15Trunk Interface Unit (TIU)........................................................................................................................16Control Unit Enclosures...........................................................................................................................17Power Supplies........................................................................................................................................18

C. KITS...................................................................................................................................................................19Millenium Badging Kit.............................................................................................................................20

D. SYNERGISTICS SOFTWARE................................................................................................................................23SynergisticsCitadel..................................................................................................................................24

E. SYNERGISTICS HARDWARE..............................................................................................................................25Citadel DRC (Dual Reader Controller)......................................................................................................26WaPac CC1065 / QRC Controller..............................................................................................................27

Enhanced Door Control Device (EDCD)...................................................................................................10Enhanced Site Control Unit (ESCU)..........................................................................................................11

Page 3: Millennium Group Dealer Catalog - …

Millennium Software

Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 1

Page 4: Millennium Group Dealer Catalog - …

On-line Network• LAN/WANnetwork• Eachsitecanhaveasecuritymanagementworkstation• Withinabuilding,thesysteminstantaneouslyprovidescomplete,prioritized,on-lineactivityreports

• Linksamulti-buildingcomplexviadedicatedordial-uptelephonelines,wirelessorfiberoptics

• High-levelaccesscontrolsystemthatreportsalleventstoaspecifiedworkstation,issuesIDcardsandprovides comprehensivemanagement tools

• Anti-passbackprotectionEconomical• Canusethewiringandreadersofanexistingaccesscontrolsystem

• Canworksimultaneouslywithupto3differentreaderprotocols

Easy to operate• Includesacompleteinteractivehelpfunction,complementedbyanoperationmanual

• EasytouseWindows®interface• Customizableoperatorlevels• Operator-configurablereportsReliable• Eachdevicecontrollerisintelligentandautonomoussothat,intheeventofacommunicationlinkinterruption,theaccesspointwillstillremainfullyoperational

High Tech• SupportsPINandcardtechnologiesbytimezone

• Native32bitapplication• Powerfuldatabasetoolstoimport

or export data to and from otherdatabase systems

• Visualalarmmapping,thepop-upgraphicalfloorplanshowstheexactlocationofanalarm

• Uptofourgraphicalfloorplanspermonitoring point

• Fullyconfigurablesystemparameters

• Scalablefrom1doorto100,000• Monitorsfrom1to700,000points• Capableofcontrollingelevatorswithamaximumof64,000floors

• Capableofcontrollingupto80,000relaydevices(on/off)

Millenium System Overview

System Features

Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 2

Page 5: Millennium Group Dealer Catalog - …

Millenium Expert

ApplicationMillenium expert is a feature rich access control system designed to fitawiderangeofapplicationsandsites.Itsarchitectureissuitedfororganizationsthatwishtomaintainasolidaccesscontrolnetworkusingdifferentcommunicationmodes.Inaddition,Milleniumexpertallowsoperators to manage their access control system from a standard PC workstationanywhereontheircommunicationnetwork.

System Capacities

Attributes

System Features

Model # Model #Picture PictureDescription Description

135-510951-FCD

135-510951-UPG

PK2934

Millenium Expert SoftwarePackage

Millenium Expert User Guide

Upgrade from version 1.1,1.5and2.1

Network License per PC

• Number of Sites:1,000• Access Points per System:100,000• Readers per Access Point: 1• Monitored Alarmed Points:700,000

• Elevator Control: 64,000floors,10,000elevatorcars

• Workstations Supported: 32• Relays Supported: 200,000(on/off)plus80,000optional

• Cardholders: Unlimited• Time Zones: 200• Alarms per Access Point: 7

including door contact

• Reliable network withdistributed intelligence:Doorsfunctionnormallyevenifcommunicationisoff-line

• Modular expansion; one door oronesiteatatime

• Economical upgrade from otheraccess control systems

• Adaptstofacilitiesofanysize• Interfaces to most types of

readers and cards in the industry• Interconnects with mostcommunicationnetworks(TCP/IP,twistedpair,leasedline,fiberoptic,dialupandwirelesstechnologies)

• ODBC compliant database witheasy data export and import

• Increased security betweenpanels with a proprietarycommunicationprotocol

Scheduler:• Book events• Scheduledoorlocks/unlocks,

even days or weeks in advance• Event Recurrence ManagerAlarm Monitoring:• Graphical Screens: 4 maps per

alarm point

• AlarmSound:Attach.wavfilesto alarms

• Acknowledgements,instructionsanddescriptionsFacility (Guard) Tours:• Up to 96 tours; global

or individualAccess Point Relays:• 2 per access point

• 8 modes available includingalarm response modes

MusterTrac Reporting:• Exceptions-Attendance• Overtime-Absence/PresenceAnti-passback:• Global,PairedorTimedMultiple Reader Technologies Supported

Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 3

Page 6: Millennium Group Dealer Catalog - …

Millenium EnterpriseApplicationMillenium Enterprise is an advanced access control system designed for multiplesiteenvironments,typicallyoveraLocalAreaNetwork(LAN)oraWideAreaNetwork(WAN).ItsarchitectureisspeciallysuitedfororganizationsthatwishtomaintainoperationsinmultiplelocationsutilizingacommonSQLServerdatabase.Inaddition,MilleniumEnterpriseallowsindividualtenants,throughdatapartitioning,tomanagetheirownbuildingusingtheirownworkstations,while giving overall control of the system to the facility manager.

System Capacities

Attributes

System Features

Model #

Model #

Model #

Model #

Picture

Picture

Picture

Picture

Description

Description

Description

Description

135-509636-UCD

135-509636-FCD

135-509636-EUD

PK2932

CALL

Millenium Enterprise SoftwarePackage

Millenium Enterprise VersionUpgrade

CCTVInterface/ Call for Details

Millenium Enterprise User Guide

Database Conversion to Millenium Enterprise

Upgrade from version 2.1/ Expert to Enterprise

Third Party Data Interface

Network License per PC

• Number of Sites:1,000• Access Points per System:100,000• Readers per Access Point: 1• Monitored Alarmed Points:700,000

• Elevator Control: 64,000floors,10,000elevatorcars

• Workstations Supported: Depends on your product licensing

• Relays Supported: 200,000(on/off)plus80,000optional

• Cardholders: Unlimited• Time Zones: Global 200 (availabletoalltenantgroups),4intervalseachzone

• AlarmsperAccessPoint:7supervised inputs with 4 states

• Reliable network withdistributed intelligence:Doorsfunctionnormallyevenifcommunicationisoff-line

• Modular expansion; one door oronesiteatatime

• Economical upgrade from otheraccess control systems

• Adaptstofacilitiesofanysize• Interfaces to most types of

readers and cards in the industry• Interconnects with mostcommunicationnetworks(TCP/IP,twistedpair,leasedline,fiberoptic,dialupandwirelesstechnologies)

• Instant alarm annunciationsupportedbymaps,sounds,instructionsandreports

• Powerful database tools toexport or import data to and fromother systems

• Increased security betweenpanels with a proprietarycommunicationprotocol

Monitoring of Alarm Points:• Broadcastingofalarm

acknowledgementtoselectedworkstations

• Independentlyprogrammonitoringoptionsateachworkstation

• Writeinstructionsforselectedalarms

• LinksoundsandmapstoalarmsGuard Tours:• Buildupto96independenttoursAnti-passback:• Global,Paired,Timed&Timeout

reset (refusal of user’s card for aselectabletimeperiod)

Controllable Relay Modes:

• Noaction;1stuserautoactivate;Autoactivate

• Validuser;Rejecteduser;Anyuser;Dual custody

• Selectedalarms;Mirrorselectedalarms; Last person out

Multiple Reader Technologies Supported

135-507591-SGL

135-101806

135-101884

Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 4

Page 7: Millennium Group Dealer Catalog - …

Millennium Xtra

Application Millennium Xtra is easy to use, fully featured access control software managed directly from an Internet Browser. With this convenience, control functions may be administered without the setup of additional, specialized workstations, saving time and money.

In the past, multiple workstations communicated with a software server with complicated connections that often presented challenges to the system administrators. Xtra simplifies this with one server and a local website accessible within the network. To add portability, any alarm event can be sent automatically via text or e-mail to any network supported device. This device can also be configured to have complete access from outside of the network. Highly secure communication protocols such as 128 bit SSL encryption ensure secure access to Millennium Xtra only for authorized personnel.

System Features • Reliable proven hardware with

modularity for flexible solutions • Data import/export capabilities• Real-time event monitoring• Multiple sessions

with different operators• E-mail/text alarm notification• Reports via scheduled e-mail• Partitioned database

• Enterprise-class software thatsupports thousands of doors

• Supports industry standard readersand cards

• Elevator Control• Multiple access levels per card• Zoned Anti-Passback• User defined data fields• Full system Lockdown

OPTIONS • exacqVision Video Interface• DMP Alarm Panel interface• Badging system• Suprema biometric readers• Salto door lock interface• Intercom interface• CBORD interface• Door toggle lock/unlock

Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 5

Page 8: Millennium Group Dealer Catalog - …

OPERATING ENVIRONMENT: Processor: 2.8 GHz or faster, 64 Bit Compatible

Memory: Minimum of 8 GB

As the system is enlarged more memory should be added to ensure adequate performance

Hard Disk: Minimum of 120 GB Allocated for Millennium

Supported Operating Systems: Windows 7 SP1 Professional 64-bit Windows 8.1 Professional 64-bit Windows 10 Professional 64-bit Windows Server 2008 R2 SP1 Datacenter 64-bit Windows Server 2008 R2 SP1 Enterprise 64-bit Windows Server 2008 R2 SP1 Standard 64-bit Windows Server 2012 R2 Datacenter 64-bit Windows Server 2012 R2 Standard 64-bit

VMWare or MS Hyper-V Virtual hosts

Millennium Xtra includes the Microsoft SQL database engine

Browsers Supported: Internet Explorer Safari Chrome Firefox

Standard Features: Unlimited number of readers

Supports Millennium Door Control Devices and Site Control Units

Up to 100,000 cardholders

Multiple cards per user

User configurable card data

30 access levels per cardholder

Scheduled door lock/unlock

Full system lockdown capability

Alarm events via text/email

Anti-Passback capabilities

Easy Card Data import/export

Elevator Control

Optional Features: Badging System Interface

Dedicated Alarm Screen for alarm only monitoring

Video integration with exacqVision

Wireless lock integrations with Salto and VingCard

Suprema Biometric reader integration

Mercury Hardware integration, EP 1501/1502, MR52, 16IN, 16OUT

DMP Alarm Panel Integration Requires IP communications board in DMP 100/500 series controls

IP Intercom interface

Custom Database integrations are available, including CBORD

Full API

Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 6

Page 9: Millennium Group Dealer Catalog - …

Millennium Hardware

Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 7

Page 10: Millennium Group Dealer Catalog - …

Door Control Device (DCD)

Application• TheDCD(DoorControlDevice)isdesignedtocontrolasingle

access point. This device can accept inputs from most readertechnology,analogalarmdevices,andanaloginputsfromrequest to exit devices.

• Intheeventofacomputerorcommunicationsfailureit willstilloperateandloghistorytransactionsintothememorybuffer.

Features• SupportsWiegandCardReaderprotocols,configurablefrom0-50bits;MagstripetechnologiesABA/ISOTrack2withconfigurabledatabits;ClockandData,andMarlokopticalkeyprotocol.

• Communicatesusingvarioustypesofsupervisedwiringmethodsincluding;Daisy-Chaining,T-Tapping,HomeRunning,StarConfiguration,andHighSecurityLoopBack.

• Upto100,000DCD’scanbeconnectedover1000SCU’s(SiteControl Units).

PartNumber–149-1000958Includedinkits135-510016and135-510017(2),

064-510299(1)and064-510430(1)

SpecificationsPower Requirements• 9-14VDC,fromourstandardPowerSupply.Currentconsumptionis50mAnominal,and150mAmaximum.

Circuit Protection• Inputpowerisprotectedfromreversepolarity,overvoltage,andtransientsurges.

DCD Device Communications• Atwistedpair,multi-drop,RS-485polling scheme is used to communicatefrom the DCD to the other MilleniumDevices.

Dimensions• 4.24”x7.35”@<1lb,10.4x18.7cm@<0.4Kg

Programmable Relays• EachDCDemploys2programmableSinglepole,FormCrelaysthatareratedfor2amps@24VDC.

Alarm Monitoring• TheDCDhasthecapabilitytomonitor

up to 7 independent alarm inputs. 4aresupervisedwith1KEOLresistors,and the other 3 are normally closedcircuits. The circuit must have a breaktimeofatleast500msforthealarmtotrigger.

All Events History Buffer• 200alleventshistory,storedinRAM

memory with a minimum of 24 hoursbackup.

Operating Temperature• 14°to104°F(-10°to40°C)lessthan90%non-condensinghumidity.

Event Buffer• 100softwareselectablepriorityevents(alarms,comfail,etc.).Theseeventsarestoredon-boardiftheSCUisoff-

line with the host computer. They can be programmed to send signals back tothecomputeriftheyareactivated.

Cover Tamper• On-boardintegratedtamperswitch.

Approvals and Listing• UL294

Model # Model #Picture PictureDescription Description

149-100958

060-101025

041-100992Door Control Device (DCD)

Standard Back Box

Back Box with Lock Cover

Seepage19forenclosurespecifications

Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 8

Page 11: Millennium Group Dealer Catalog - …

Site Control Unit (SCU)

Application• TheSCU(SiteControlUnit)isacommunicationshubandmemorybufferforthedoorcontrollersandotherdeviceswithin the Millenium family. A single SCU can support up to100DCDS,4ECUsand10ECDs.On-boardsecuritymeasuresensuretheintegrityofthedataaswellaspreventingattemptedhackingorpiratingofaccounts.

Features• Allbi-directionalcommunicationstoandfromthePCcanuseeitherRS-232orRS-485protocols

• Communicationsfortheaccesscontroldevicenodeuseatwistedpair,shieldedcableonanRS-485bus

• Upto1000fullysupervisedSCUscanbeconnectedtoasinglePCrunningtheMilleniumforWindows®software• TheSCUiscompatiblewithallofthepopularcommunicationmodesfoundintoday’sinstallationenvironments:dial-up,fiberoptic,leasedline,radiofrequency,andTCP/IPNetworkingprotocol

SpecificationsPower Requirements:• 9-14VDC,suppliedbytheKabaPS1powersupply;Currentconsumptionis50mAnominal,and90mAmaximum

Circuit Protection:• Inputpowerisprotectedfromreversepolarity,over-voltageandtransientsurges

PC and SCU Communications:• RS-232viaDB-9Fconnectorora4-wireRS-485connectionusingterminalblocks.(RS-485requiresTIU)

SCU Device Communications:• Atwistedpair,multi-drop,RS-485polling scheme is used to communicatewith other Millenium devices

Dial-up Modem Support:•HayesATcommandset,at9600baud.

• Callbackfeaturewheneventbufferis80%full,orfollowingspecificevents

Supervisory Relay:• A2Amp,24VDC,singleFormCrelay that changes state when the SCU loses communicationwiththeotherboard systemAll Events History Buffer:• 2000event,storedinRAMmemory

with a minimum of 24 hours backupPriority Event Buffer:• 100softwareselectablepriorityevents(alarms,comfail,etc.)• Theseeventsarestoredon-boardiftheSCUisoff-linewiththehostcomputer. Stored events are sentto the host computer oncecommunicationsarere-established

Cover Tamper Switch:• On-boardintegratedtamperswitchExternal Clock Sync:• Terminalblockconnectionsareavailableforsynchingtherealtime clock to an external AC source • UsedforinternationalACsituationsandinfrequentcall-insApproval and Listings:• UL294Operating Temperature:• 14°to104°F(-10°to40°C)lessthan90%non-condensinghumidityDimensions:• 4.24”x7.35”@<1lb• 10.8x18.7cm@<0.45Kg

Model # Model #Picture PictureDescription Description

149-101117

060-101025

041-100992Site Control Unit (SCU)

Standard Back Box

Back Box with Lock Cover

Seepage19forenclosurespecifications

Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 9

Page 12: Millennium Group Dealer Catalog - …

Enhanced Door Control Device (EDCD)

Specifications

Application • The EDCD (Enhanced Door Control Device) offers a larger

cardholder database and significantly faster processing andcommunications speed than the standard DCD. It controls asingle access point accepts connections to most readertechnologies.

• Stores data for up to 60,000 cards. Because the cardholderaccess levels are stored here, in the event of a computer orcommunications failure it will provide uninterrupted access control and log up to 2000 transactions into memory.

Features • Supports Wiegand Card Reader protocols, configurable

from 0-256, Magstripe formats of ABA/ISO Track 2 withconfigurable data bits; Clock and Data, and Marlok.

• Communications between EDCDs is via RS-485 using varioustypes of supervised wiring methods; Daisy-Chaining, T-Tapping, Home Running, and High Security Loop Back.

• EDCD’s communicate to the Millennium Software throughSite Control Units (SCU or ESCU). Each SCU/ESCU can supportup to 99 EDCDs, depending on system configuration needs.

Card Data Storage • Each EDCD stores data for up to 60,000

cards

Transaction History Buffer • 2,000 transaction history providesretention of card activity ifcommunications with the ESCU is lost

Alarm Event History Buffer • 100 software selectable alarmevents (alarms, com fail, etc.) arestored if communications with theESCU is lost.

EDCD Device Communications • A twisted pair, multi-drop, RS-485

polling scheme is used to communicatebetween the EDCD, the ESCU, andother Millennium Devices.

Programmable Relays • Each EDCD includes 2

programmable Single pole, Form Crelays that are rated for 10 amps @24 VDC. These are typically used fordoor locking devices

Alarm Monitoring • The EDCD has the capability to monitor

up to 7 independent alarm inputs. 4are supervised, and the other 3 arenormally closed circuits.

Circuit Protection • Input power is protected from reverse

polarity, over voltage, and transientsurges.

Operating Temperature • 14° to 104°F (-10° to 40°C) less than

90% non-condensing humidity.

Power Requirements • 9-14 VDC, from our standard PowerSupply. Current consumption is 50mAnominal, and 150 mA maximum.

Cover Tamper • On-board integrated tamper switch.

Approvals and Listing• UL 294 pending

Dimensions• 4.24” x 7.35” @ < 1lb, 10.4 x 18.7cm

@ < 0.4Kg

Model # Picture Description Model # Picture Description

149-101966

Back Box with Lock and cover

041-100992EDCD Door Control Device

060-101025 Standard Back Box

Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 10

Page 13: Millennium Group Dealer Catalog - …

Enhanced Site Control Unit (ESCU)

Application • The Enhanced Site Control Unit (ESCU) is a communications

hub and memory buffer that sits between Millenniumdevices (DCD/EDCDs, ECUs, etc.), and the Millennium software running on a computer/server. Depending uponsystem operational needs and configuration, a singleESCU can support up to 99 DCD/EDCDs or 4 ECUs and 10ECDs.

Features • All communications between the ESCU and the

computer/server is IP which connects via anEthernet socket on the ESCU. Communicationsbetween the ESCU and the Millennium devices isRS-485, on a twisted pair, shielded cable.

• When used with EDCDs, the communications speedon the RS-485 network can be as high as 38.4k.

• Depending upon the Millennium software chosen, up to 1000 fully supervised ESCUs can be connected to a singleComputer/Server.

Specifications

Computer to ESCU Communications: • IP via the on board Ethernet

connector and Cat5/Cat6 cable.ESCU t o M i l l enni um Device Communications: • Two wire, multi-drop, RS-485 via

shielded, twisted pair

Transaction History Buffer: • 2000 event on board storage

Alarm Event History Buffer: • 100 software selectable priority event

(alarms, com fail, etc.) storage• These events are stored on-board

if the ESCU is off-line with the hostsoftware. Stored events are sent tothe host software oncecommunications are re-establishedCircuit Protection:• Input power is protected from

reverse polarity, over-voltage andtransient surges

Power Requirements: • 9-14 VDC, supplied by the PS1 power

supply; Current consumption is 50mAnominal, and 90mA maximum

Cover Tamper Switch: • On-board integrated tamper switchApproval and Listings:• UL 294 pendingOperating Temperature:• 14° to 104°F (-10° to 40°C) less than

90% non-condensing humidityDimensions: • 4.24” x 7.35” @ < 1lb• 10.8 x 18.7cm @ < 0.45Kg

Model # Picture Description Model # Picture Description

149-101992 Site Control Unit (SCU) 041-100992 Back Box with Lock Cover

060-101025 Standard Back Box

Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 11

Page 14: Millennium Group Dealer Catalog - …

Elevator Control Unit (ECU)

Application• TheECU(ElevatorControlUnit)isthedevice

that interfaces between the SCU and the ECDs.EachECUhas16built-inrelaystocontrolelevatorfunctions.Upto4ECUscanbeconnectedtoasingleSCU,givingtheMilleniumsystemthecapabilityofcontrollingupto64,000floorrelays.

Features• Controlsasmanyas10elevatorcarsand64floorswhenfourunitsarecascadedonasingle SCU.

• 10,000usercapacity.WhenfourunitsareconnectedtogetheronasingleSCU,40,000users are available.

Specifications

Input Power Requirements:• 120VACinputona2Ampunswitcheddedicatedcircuit(EC2-101190)

• Forinternationalpowerrequirementsthereisa240VACmodelavailable(EC2-101191)

Programmable Relays:• EachECUemploys16programmablesinglepole,FormCrelaysthatareratedfor5Ampsat24VDC

All Events History Buffer:• 2000events,storedinRAMmemory

with a minimum of 24 hours backupAlarm Monitoring:• Monitorsupto4independent

Normally Closed (nonsupervised) alarm inputs. The circuit must have abreaktimeofatleast500msforthe alarm to triggerPriority Event Buffer:• 100softwareselectablepriorityevents(alarms,comfail,etc)

• Theseeventsarestoredon-boardiftheECUisoff-linewiththehostcomputer. Stored events aresent to the host computer once

communicationsarere-establishedCover Tamper Switch:• On-boardintegratedtamperswitch

Fuse Protection:• A2Ampslowblowfuseprotectsthe

AC inputKeyswitch Override:• UsedbyFireDepartmentpersonnel

to override the access control systemduring an emergency

Operating Temperature:• 14°to104°F(-10°to40°C)lessthan90%non-condensinghumidity

Dimensions:• 14.25”X12.25”X4.25”@20lbs• [email protected] / Listing:• UL294

Model # Picture Description

EC2-101190

EC2-101191

120VElevatorControlUnit

240VElevatorControlUnit

Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 12

Page 15: Millennium Group Dealer Catalog - …

Elevator Control Device (ECD)

Application• The ECD (Elevator Control Device) allows a key/card reader

to communicate with the Elevator Control Unit (ECU) in orderto control elevator access.

Features• SupportsWiegandcardreaderprotocols,configurablefrom0-50bits;magneticstripetechnologiesABA/ISOTrack2withconfigurabledatabits;Marlok™opticalkeyprotocol

• TheECDcommunicatesusingasupervised,home-runwiringconfigurationtotheECU

• Upto10ECDscanbeconnectedtoasingleSCUunit,withmaximumarchitectureof10,000ECDspersystem

Specifications

Power Requirements:• 9-14VDC,suppliedbya9VDCclassIIplug-intransformer;Currentconsumptionis50mAnominal,and100m maximum

Circuit Protection:• Inputpowerisprotectedfromreversepolarity,over-voltageandtransientsurges

ECD Device Communications:• Atwistedpair,homerun,RS-485

polling scheme is used tocommunicate from the ECD to the ECU

Cover Tamper Switch:• On-boardintegratedtamperswitchOperating Temperature:• 14°to104°F(-10°to40°C)lessthan90%non-condensinghumidity

Dimensions:• 4.25”X7.35”@<1lb• 10.8x18.7cm@<0.45KgCertification / Listing:• UL294

Model # Picture Description

149-101179

060-101025

Elevator Control Device (ECD)

Standard Back Box

Model # Picture Description

041-100992 Back Box with Lock Cover

Seepage18forenclosurespecifications

Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 13

Page 16: Millennium Group Dealer Catalog - …

Relay Control Device (RCD)

Application• The RCD (Relay Control Device) expands the controlcapabilitiesofMillenium.TheRCDisanadd-onboardthatcancontrolupto8additionalprogrammablerelays,foranyproduct that requires voltage switching. It operates and logshistorytransactionsintothememorybufferevenifcommunicationswiththeSCUhavebeeninterrupted.

Features• EachRCDhas8individuallyisolatedsinglepole,FormCrelayoutputs,whichcanbeprogrammedforactivationbyavariety of triggering sources

Specifications

Power Requirements:• 9-14VDC,suppliedbytheKabaPS1powersupply;Currentconsumptionis50mAnominal,and200mAmaximum

Circuit Protection:• Inputpowerisprotectedfromreversepolarity,over-voltageandtransient surgesRCD Device Communications:• ATwistedPair,RS-485pollingscheme

is used to communicate with the otherMillenium Devices

Programmable Relays:• EachRCDemploys8programmable

singlepole,FormCrelaysthatareratedfor2Ampsat24VDCAll Events History Buffer:• 2000event,storedinRAMmemory with a minimum of 24 hours backupPriority Event Buffer:• 100softwareselectablepriorityevents(alarms,comfail,etc.)

• Theseeventsarestoredon-boardiftheRCDisoff-linewiththehostcomputer. Stored events aresent to the host computer oncecommunicationsarere-established

Cover Tamper Switch:• On-boardintegratedtamperswitchOperating Temperature:• 14°to104°F(-10°to40°C)lessthan90%non-condensinghumidity

Dimensions:• 4.24”x7.35”@<1lb• 10.8x18.7cm@<0.45kgCertification / Listing:• UL294

Model # Model #Picture PictureDescription Description

149-100993

060-101025

041-100992Relay Control Device (RCD)

Standard Back Box

Back Box with Lock Cover

• TheRCDcommunicatesusingvarioustypesofsupervisedwiringmethods,includingDaisyChaining,T-Tapping,HomeRunning,StarConfiguration,andHighSecurityLoopBack

• Upto10RCDscanbeconnectedtoasingleSCU,withamaximumarchitectureof80,000relayspersystem

Seepage18forenclosurespecifications

Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 14

Page 17: Millennium Group Dealer Catalog - …

Millenium Site Ethernet Interface (SEI)

Application• TheSEI(SiteEthernetInterface)isdesignedtoprovidecommunicationsbetweentheMilleniumPC and the Site Control Unit(s) by means ofEthernetNetworksutilizingaTCP/IPprotocol.

SpecificationsPower Requirements• 12-15VDC,suppliedbyeitheracentralpowersupplyoranauxiliarypowersupply,700mAmaximum.

Model # Picture Description

051-507972

051-509428

Site Ethernet Interface(SEI)120V

Site Ethernet Interface(SEI)220V

IP Address Setting• SoftwarethroughRS-232port,or

through TelNet

Data Backup• Nonvolatilememory

Network Interface• 10baseT• StaticIP

SCU Interface• RS-232-CCommunications Protocol (Network)• TCP/IP

Communications Protocol (SCU interface)• Proprietary

Operating Environment• 32°to104°F(0°to40°C)lessthan90%non-condensinghumidity

Dimensions• 7”X6”X11/4”@21lbs• [email protected]

Minimum Requirements• MilleniumWindows®version1.5

and up

Installationdiagramshowing the Millenium Server/Workstationconfigurationandmixedcommunicationmodes.

Ethernet

Millenium® Server PCSEI

Millenium® Workstation

Millenium®Workstation

Modem

SCU#2

SCU#1

SEI

SCU#3

SCU#4

Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 15

Page 18: Millennium Group Dealer Catalog - …

Model # Picture Description

135-101186-001

135-101186-002

135-100957-001

135-100957-002

051-507968

051-507967

003-101394

003-101395

120VTIUHardwarepackage,withoutMarlokkeyreader.Includes:TIU(120V),walltransfomer&manuals.Formagneticstripe

card,biometricsandtouchkeyaccess.

240VTIUHardwarepackage,withoutMarlokkeyreader.Includes:TIU(240V),walltransfomer&manuals.Formagneticstripe

card,biometricsandtouchkeyaccess.

120VTIUHardwarepackage,withMarlokWedgekeyreader.Includes:TIU(120V),walltransfomer&manuals.

For Marlok key access.

240VTIUHardwarepackage,withMarlokWedgekeyreader.Includes:TIU(240V),walltransfomer&manuals.

For Marlok key access.

TIUPack120VReplacement TIU and wall transformer

TIUPack240VReplacement TIU and wall transformer

120Vto9VDCwalltransformer500mAforTIU

240Vto9VDCwalltransformer500mAforTIU

Trunk Interface Unit (TIU)

ApplicationTheTIU(TrunkInterfaceUnit)isanRS-232toRS-485dataprotocolconverter.Itisusedwhenthe Site Control Unit (SCU) is located more than 50ftfromthecomputerorwhenmultipleSCUsaredaisy-chainedinthesamebuilding.

System Features• ConvertsRS-232protocoltoRS-485protocolforlongercommunicationcablingdistances

• FrontpaneldiagnosticlightsforinstantverificationofcommunicationstatusbetweenthecomputerandtheSCU

SpecificationsPower Requirements• 9-14VDC,suppliedby9VDC

class ll plug in transformer; Currentconsumptionis50mAnominal,100mAmaximum

Connection to the PC• 15”cablewithaDB-9Fconnector

Connection to the SCU• RS-485,5conductor,shieldedcableCommunications Distance• Upto5000ftfromthecomputerto

the last SCU on the trunk

Operating Temperature• 14°to104°F(-10°to40°C)lessthan90%non-condensinghumidity

Dimensions• 3.60”x5.20”x1.30”at2lbs.• 9.1x13.2x3.3cmat0.90Kg

Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 16

Page 19: Millennium Group Dealer Catalog - …

Control Unit Enclosures

Control Panel Enclosure• TheControlPanelisbuiltofheavy14-gaugesteel,andincludesabackplatereadytoreceivecombinationsof3Milleniumcircuitboards.Theeasytoremovebackplateallowsforquickassembly,wiringandtestingatthedealer’sfacilitiespriortoinstallation.Thecontrolpanelcanthenbewallmountedwithoutremovingtheback plate.

• Thebackplateconsistsofgalvanizedsteelincluding12stainlesssteelstand-offspositionedtoseatuptothreeMilleniumcontrolboards.AnycombinationofthreeDCDs,SCUs,orRCDscanbequicklysnappedon.

• Thebeigepaintedcontrolboxincludesacamlock,2keys,afulllengthpianohinge,ventilationholesand6knock-outs.

• 14.2”x12.2”X4.1”-36.2x31.1x10.5cm

Back Box Package• ScrewMountedCover• MountstheDCU• 111⁄2”X51⁄4”X13⁄4”(292mmX133mmX44mm)• IncludesmetalStand-off

Surface Box• CamlockMountedCover• MountstheFCUorDCU• 103⁄4”X103⁄4”X23⁄4”(273mmX273mmX70mm)• IncludesmetalStand-off

#062-510235

041-100992

#060-101025

Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 17

Page 20: Millennium Group Dealer Catalog - …

Model # Picture Description

PS1-100212-001

PS1-100213-001

WPT-1

PS2-510068

124-033067

EPS-1

132-024003

132-100780

PowerSupplyand8AHBatteries,120V/60Hz5A/12V,lineconditionerandbatteriesincluded.

ULListed(294),CSAListed(1950)

PowerSupplyand8AHBatteries,240V/50Hz5A/12V,lineconditionerandbatteriesincluded.

CSA Listed (1950)

Wire-InTransformer120Volts-1A/12VOptiontoEPS-1.Mayberequiredbysomecities

PowerSupplyandCharger120V/60Hz12V,2.5AmpKeyLockableCabinet

(Withoutlineconditioner)Includeswalltransformer

LineConditionerPCBforPS1

PowerSupplyand4AHBattery,120V/60Hz1A/12V.(Withoutlineconditioner)

Battery,6V8AHgelledleadacidforPS1(2 required per power supply)

Battery,12V4AHforEPS-1(One required per power supply).

Power SuppliesApplication• ThePS1powersupplyisarobustfilteredDCpowersourceforthe

Millenium controller boards. Its secondary board generates the necessarybiasingvoltagesfortheRS-485communications,whichlinkthecontrollerboards to the Site Control Unit.

• Includesbatteries,enclosure,andkeylock

SpecificationsInput Power Requirements• Requires120VACor220VACinputon

a 5 Amp unswitched dedicated circuitOutput Power• Deliversaregulatedandfiltered13.8VDCoutputat5Amps

Battery Backup• Usestwo6Volt,8Ampleadacidtypebatteries

Fuse Protection• TheACinputisprotected

by a 2 Amp low blow fuse

• A5Ampslowblowfuseisusedtoprotectthebatteries

Protection• TheDCoutputiscurrentlimited

against possible short circuits• ACfailuremonitoring• FormAoutputformonitoringthe

status of the AC input

Cover Tamper Switch• FormAoutputtomonitorthestatus

of the enclosure door

Approvals and Listings• UL294,CSA1950

Operating Temperature• 14°to104°F(-10°to40°C)lessthan90%non-condensinghumidity

Dimensions (PS1-100212-001) (PS1-1002213-001)• 14.25”x12.25”X4.125”@27lbs• [email protected]

Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 18

Page 21: Millennium Group Dealer Catalog - …

Millennium Kits

Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 19

Page 22: Millennium Group Dealer Catalog - …

Millenium Badging Kit

Attributes

System Features

Automatic Portrait Background:• Changecolorortexturebehindthe

portrait without retaking itAdobe and TrueType Font Support:•UseanyWindows®font,including Adobe Type 1• AdobefontsrequireAdobeType

ManagerJPEG Compression:• Portraitstoragesizeis

approximately 10KB per image• ImportsandexportsTIFF,PCX,BMPandotherimagefileformats

Ghost Image / Electronic Overlay:• Turnanygraphicimageintoan

electronic overlay to cover part ofthe portrait and data

• Printaduplicate,semi-transparentcopy of the portrait on the badgefor added security

Connectivity to Standard Databases• ODBCcompliantimport/exportutilityReporting:• SortandselectonanydatabasefieldNetwork Support• Multiworkstationsupport;securityguardsatanystationcanmatch the user photo from thedatabase with the person thatrequested access

• Supportssignaturepadsandmagneticstripeencoding

Password Protection• Assignseachoperatorasecurityleveltoprotectconfidentialend-userinformation

Badge Creation History• Automaticallymaintainshistoryofbadgeissuedate,alongwithreasons for issue and operator

Remote Camera Control• Zoom,orAuto-centerportrait

with keyboard or mouse• Color,brightness,contrast

and white balance remotelyadjusted

• Supportsprintingtoproximity,Wiegand card formats and encodingofmagneticstripes

• Millenium2.1/ExpertorEnterprisesoftwareapplication

• Windows98SEandabove• Easytousegraphicaluserinterface• User-friendlycardlayout• Draganddropplacementofgraphic

elements

• Multiworkstationsupport;securityguardsatanystationcanmatchtheuser photo from the database withthe person that requested access

• SupportssignaturepadsandmagneticstripeencodingPasswordProtection

• Assignseachoperatorasecurityleveltoprotectconfidentialend-

userinformation

• Includesstaticandvariabletext• Automaticallymaintainshistoryofbadgeissuedate,alongwithreasonsfor issue and operator

• Zoom,orAuto-centerportraitwith keyboard or mouse

• Color,brightness,contrastandwhitebalanceremotelyadjusted

ApplicationThe Millenium Badge Module allows you to create and supply your own photo ID badges. It consists of several optionstofityourneeds:asoftware-controlleddigitalcamera,ahigh-endimagingcapturecard,andpowerfulWindows®-basedsoftware.Badgescanincludeabarcode,digitalsignatureormagneticstripeencodingcompatiblewithouron-lineandstandaloneelectronic access control systems.

Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 20

Page 23: Millennium Group Dealer Catalog - …

Millenium Badging Kit (continued)Attributes

Multiple Video Inputs• Supportedvideoinputsandformats

include composite NTSC andPAL,S-VHS&RGBforworldwideapplications

• Built-inTWAINinterface(forportable digital cameras andscanners)

Printer• Multipleprintersupport• UseanyWindows-compatibleID

card printerPrinting• Unattendedbatchprintingorbadgesbyname,IDnumber,typeor report

• PrintreportswhichincludephotoIDonanyWindowscompatibleprinter

• Doublesizedbadgeprinting(withcompatibleprinter)

• PrintWindowsbarcodefonts• Producecopy-proofoverlaysfor

placement over bar codes

Reporting• Sortandselectonanydatabasefield

Minimum PC requirement• Pentium®PCwith2serialports• SVGA15inchmonitor• Mouse&keyboard• 800X600VGAscreenresolutionComponents• MilleniumBadgeModuleapplication

• SecuritykeyOptional components• Signaturepad• FlashPointhighresolutionSVGA

capture card• CCDhighresolutioncamera,withremotecontrolandzoom

• Portraitlightingkitwithdesktopbase

• Systemcables• Factory-presetPC

• Modularpackagesavailableforyourspecificneeds

Supplies• MosttypesofPVCcards

Model # Picture Description

135-509233

1600-30-1260

1600-30-1280

1600-30-1270

1600-30-1280 Badging Camera with Light Kit and Stand

Hardware Kit #1Includes:Pentiumprocessor,15”colormonitor,keyboardandmouse.PCspecificationsubjecttochange.Askyoudealerforinformation.ImageCapturecard-PCI,portraitlightkit,light

andcamerastand,anddigitalcamera.

Hardware Kit #3Includes:Lightandcamerastand,ImageCapturecard-PCI,computer. This kit can be used worldwide regardless of the

TVstandardandvoltage.

Hardware Kit #2Includes:ImageCapturecard-PCIwithcable(toVHScamera).UsedincombinationwithMilleniumbadgesoftwareandportabledigitalcameraorvideocamera.Thiskit

canbeusedworldwidewherethePAL,NTSCorSCCAMvideostandardsapply.

MilleniumBadgesoftwareonlyadd-onmoduleOnCD-ROM.RequiresMilleniumversion2.1/Expert,Millenium

Enterprise. Includes: Quick Start Guide and security key.

Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 21

Page 24: Millennium Group Dealer Catalog - …

Millenium Badging Kit (continued)

Model # Picture Description

M9005-724

M9005-725

M9005-726

M9005-727

M9005-751

N9005-761Med

M9005-772

M9005-946

M9006-381

PF3

PCF6

PCX

PC1

CK1

120-509157

PCX-PF2

Magicard Rio single side color card printer

Magicard RioM single side with mag encoding

Magicard RioMS single side with mag + chip encoding

Magicard RioS single side with chip only

MagicardRioLC1/D5panelcolordyefilmYMCKO-350images

Magicard Rio Cleaning Kit (medium 10 cards/ 2 pens/ 3 cleaning rollers)

MagicRio/Tango5tackyrollers-cleaningsystem

MagicardRioCleanCards(bulk-10perpackage)

AltoMsinglesideentrylevelhandfeedprinterwithMagneticencoder

Alto500shotblackresincassettedyefilm

Alto100PVCcardsindispensersplus100shotPF2cassetteYMCKO

Alto empty card dispenser

Alto50PVCblankcardsindispenser

Altocleaningkit(5-Tcards,1pen)

SignaturePad,PressureSensitiveTouchPad1024x1024,418x789DPI

Alto2qty.reader-to-fill50-cardcapacitydispensersforloadingtechnologycardsplus100shotPF2cassetteYMCKO

Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 22

Page 25: Millennium Group Dealer Catalog - …

Synergistics Software

Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 23

Page 26: Millennium Group Dealer Catalog - …

Synergistics CitadelApplicationCitadelisamodern,affordablemulti-siteaccesscontrolsystemdesignedtocontrol a single building or a virtually unlimited number of buildings using either directconnectionoverwireorfiber,orremoteconnectionoverdialuptelephonelines. Data entry is supported at the host computer which may be shared with other programs while Citadel is running in background. Access control and alarm monitoring are performed at each controller from distributed databases where all trancactionsareloggedtemporarilyforscheduledhostuploadingandinputpointalarmsarereportedinrealtimetothehostcomputer.

Attributes

System Features

Model # Picture Description

CitadelSW31-0001

31-0002

Citadel System SoftwarePackage

Citadel Firmware used for upgrades from Building Watch

Alarm Monitoring AndI/O Specifications:• Supports5inputpointspercontroller,(expandableto13)

• Supports5relayoutputpointspercontroller,(expandableto13)

• Supportsinputtooutputpointmapping

• Timedinputpointmasking• Timescheduleuploadingofsitetransactionlog

• Realtimeandautomaticuploadingof alarms to host computer

• InputpointstatusannunciationinactivealarmWindow

• Timedelayeddoorajarmonitoring(door open too long)

• Monitorsforceddooranddoorajarwithasingleinputpoint

System Logging:• ScheduledTransactionLogging• RealTimeAlarmLoggingCommunications:• RS232Serialportcommunications

between host computer and sites.

• Supportsdirectwirecommunicationwith local site.

• Supportsdirectmodemcommunicationswithlocalsite

• Supportstelephonedialupcommunicationswithremotesites

• Hostcomputertositecommunicationsbyanyoralloftheabovemethodsofcommunications

• RS4852wiremulti-dropcommunicationsbetweensitecontrollers

• True distributed processing system• 4,000 Cardholders per controller• Single or block entry of cards• Easy database backup and restore

from within the softwareprogram

• Card issue levels for mag stripecards

• System database stored inMicrosoft Access

• Supports report generation

• User defined card format• 32 card readers or keypads

per site• Supports all common card

technologies• Supports biometrics and keypads• Supports multiple reader

technologies per system• Supports 208 input points per site• Supports 32 programmable

privilege groups per site• Supports 64 programmable time

schedules per site• 32 Programmable holidays• Supports virtually unlimited dial- up sites)• Supports 2 direct wired sites from

serial port configuration.• Timed Door Control• Antipassback• Supports optional video image

personnel identification badgedesign, printing and management

Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 24

Page 27: Millennium Group Dealer Catalog - …

Synergistics Hardware

Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 25

Page 28: Millennium Group Dealer Catalog - …

Model # Picture DescriptionDRC2032C31-0005

DRC2032CB31-0012IO200031-1004

CitadelDualReadercontroller(includesenclosure&powersupply)

Citadel I/O expansion board with (8) inputs and (8) outputs

CitadelDualReadercontrollerandpowersupplywithbatterybackup. Card readers not included. All listed card readers may be used with this product.

Citadel DRC (Dual Reader Controller) ApplicationThe Citadel DRC (Dual Reader Controller) is designed to control 2 access points. The DRC’s 2 card reader input ports can accept input from most reader technologies,analogalarmdevices,andanalogrequesttoexitdevices.TheDRCisequipped to control 4 output relays (2 door relays + 2 auxiliary relays). In the event ofacomputerorcommunicationfailure,itwillcontinuetooperateandloghistorytransactionsintothememorybuffer.Expandingbeyond2doorsissimpleandinexpensive with the Citadel system; up to 16 DRC panels can be linked together usingasecondaryRS-485network.

Specifications

System Features

Power Requirements:• 12VAC40VA

PC to DRC Communications:• IPnetwork(Ethernet)• SerialRS-232• Dialupmodem

DRC to DRC Communications• RS-485Network

Circuit protection• CardReaderandotherinputports

are protected from over voltage andtransient surges

Programmable Relays• EachDRCemploys2programmablesingle-pole,dualthrowrelaysthatareratedfor10Ampsat250VAC

All Events History Buffer• 2000transactioneventstoredinbattery-backedRAMmemory

Alarm monitoring• TheCitadelDRCcanmonitor

independent alarm inputs includingdoorforcedandotheruserdefinableinputpointsinrealtime.Whendialupcomm.isused,DRCwillinitiateacall to the host in the event of an

alarm.

Event Buffer• Eventsstoredon-boardwithhost

selectable upload frequency. Alarmssent to host immediately.

Approvals and Listing• UL294Equivalent?

Operating Temperature• 14ºFto104ºF(-10ºto40ºC);<90%non-condensinghumidity.

Dimensions and Weight• 8.5”x7.5”@<1lb

• SupportsWiegandprotocols,configurablefrom0-50bits,andmagneticstripetechnologiesABA/ISOTrack2withconfigurabledatabits.

• EachDRCcanbeconfiguredtocommunicate directly to the host PCviaadirectseriallink(RS-232),dial-upmodem,orthroughanIPnetwork.

• 2Readers• 2DoorRelays• 2AuxiliaryRelays• 5Inputpoints(expandsby8withoptionalIOE)

• Upto16DRC’scanbelinkedtogetherthroughasecondarytwisted-pairRS-485networkeliminatingtheneed for a Site Control Unit. In suchaconfigurationoneoftheDRC’satthe site is connected to the host PCandactsasthemasterDRC,whileupto15additionalslaveDRC’sarelinkedto the PC through that DRC via thesecondaryRS-485network.

• 4,000–8,800cardspercontroller• Standardanduser-definedcard

formats

• 1Alarmoutputpoint(expandsby8withoptional(IOE)

• TimedDoor/AuxRelayControl• InputandOutputpointmapping• 4-digitPIN• 32privilegegroupspersite• 64timeschedules+32holiday

schedules per site• Usesbiometricsandkeypads• Transactionlogging• Realtimealarmmonitoring• Anti-passback• Automatictransactionuploading

Copyright © Millennium Group, Inc. | 16 Tech Circle | Natick, MA 01760 | P: 866.455.5222 F: 508.651.2902 | www.millennium-groupinc.com 26

Page 29: Millennium Group Dealer Catalog - …

WaPac CC1065 / QRC ControllerSystem Features

• WapacorXtrasoftwarecompatible• Supportfor20,000Cards,Expandableto80,000• 1,000EventBuffer• Stand-AloneDistributedProcessing• 64TimeSchedules• 64AccessCodes• 64ProgrammableHolidaySchedules• 4CardReadersPoints• 4DoorInputPoints• 4RequesttoExitInputPoints• 45A30VDCDoorRelays• 45A30VDCAuxiliaryRelays• 4AuxiliaryInputs• 1DedicatedAlarmOutput• CoverTamperInput• CommunicationsStatusIndicator

Model # Picture Description

CC1065TAW06-5005

CC1065NW06-5009

CC1065DAW06-5013

PIO1060AREW06-6002

PIO1060AW06-6004

QRC1065W41-0015

QRC1065WPB06-4055

CC1065NWPB06-4068

CC1065NWMPB06-4069

CC1065DAWMPB06-4067

21-0062

MOD56

WaPacDial-upCommunicationControllerAssemblyProvidesdialupmodemcommunicationswithhostcomputer.Assemblyincludesenclosure/powersupply,communicationscardfordialupandQRCBoard.Includessupportfor(4)readersand(9)I/Os.Requires(2)modems,pleaseseePart#09-0010

WaPacNetworkCommunicationControllerAssemblyProvidesnetworkcommunicationswithhostcomputer.Assemblyincludesenclosure/powersupply,LantronicscommunicationscardfornetworkcommunicationsandQRC

board. Includes support for (4) readers and (9) I/O’s

WaPacDirect-WiredCommunicationControllerAssemblyProvidesdirectwiredcommunicationswithhostcomputer.Assemblyincludes

enclosure/powersupply,CommunicationscardfordialupcommunicationsandQRCboard. Includes support for (4) readers and (9) I/Os.

Programmable (16) input point and (16) relay output controller for WaPac May be used for elevators and alarm points

Programmable (16) input point controller for WaPac. No relays on panel

WaPac Quad reader controller. Includes support (4) readers and (9) I/OsAssembly includes enclosure/power supply

WaPac Quad reader controller. Includes support for (4) readers and (9) I/Os

WaPacnetworkcommunicationscontrollerforTCP/IP,includingLantronicscommunicationcard

WaPacnetworkcommunicationscontrollerforTCP/IP,includingLantronicscommunicationcardandexpandedmemory

WaPacdirect-wiredcommunicationscontrollerwithexpandedmemory

WA-PACDOStoWA-PACPROfirmwareUPGRADE/formulti-cardformat,orolderfirmware