+ All Categories
Home > Documents > Open Internet Explorer to your Integrad® Website. · Left click and drag to re-center or scroll...

Open Internet Explorer to your Integrad® Website. · Left click and drag to re-center or scroll...

Date post: 19-Aug-2020
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
17
1 Open Internet Explorer to your Integrad® Website. Always answer “Yes” to security questions. Login Type your username, then password. Click Login (or use Enter key). Patient Selection Select an appropriate Tab, or use to search for patient exams. Note: All examinations should be viewed using Lossless Wavelet Compression If images are not loaded in lossless compression, the lossy compression is indicated in the lower left corner of the image. Tip- Pointing the mouse at an icon will define its function. Pop-up Menus can be opened by a right click.
Transcript
Page 1: Open Internet Explorer to your Integrad® Website. · Left click and drag to re-center or scroll image. Tips- Hold middle mouse button to zoom. Select Click on the Select icon. Left

1

Open Internet Explorer to your Integrad® Website. Always answer “Yes” to security questions. Login Type your username, then password. Click Login (or use Enter key). Patient Selection

Select an appropriate Tab, or use to search for patient exams. Note: All examinations should be viewed using Lossless Wavelet Compression

If images are not loaded in lossless compression, the lossy compression is indicated in the lower left corner of the image.

Tip- Pointing the mouse at an icon will define its function. Pop-up Menus can be opened by a right click.

Page 2: Open Internet Explorer to your Integrad® Website. · Left click and drag to re-center or scroll image. Tips- Hold middle mouse button to zoom. Select Click on the Select icon. Left

2

Search and Tabs

Use the search engine to define parameters, and then click on search. To save the search results as a permanent tab, right click on the red Search Results tab. Click on Save Search as…to enter a name and save the tab. To move or delete tabs, make the tab active by left clicking on it, then right click for options menu. Tip- Filters can be customized to create tabs by study description, such as Neuro or Body tabs. Viewing Single click on the highlighted line to open a patient’s exam. ↓ MAIN MENU ↓

↑ MAIN TOOL BAR ↑ Page/Scroll

When the exam opens, Page/Scroll mode is enabled on the main toolbar. To page through images, click on a series to activate it.

• Drag left mouse button. • Scroll using mouse wheel. • Left/middle click. • Use up/down arrow keys or page up/page down keys.

Shortcuts-

Right click for pop-up menu. Right click and drag to adjust Window/Level. Space bar to toggle preset Window/Levels. Hold F2 for Triangulation mode.

Page 3: Open Internet Explorer to your Integrad® Website. · Left click and drag to re-center or scroll image. Tips- Hold middle mouse button to zoom. Select Click on the Select icon. Left

3

Exchange Window Position

To quickly swap series positions, click and drag the series exchange icon from one series, and drop it inside another series. ↓

Window/Level Adjustment and Histogram Analysis

Click on the Window/Level icon. For manual manipulation- Left click and drag to adjust Window/Level. R/L adjusts window; up/down adjusts level. For histogram analysis (sets the intensity automatically of a defined region of interest)- Select the ROI with right mouse button. Tips-

While in mode, use mouse wheel or keyboard to scroll images. To restore original setting, right click and select from Preset Window menu.

Page 4: Open Internet Explorer to your Integrad® Website. · Left click and drag to re-center or scroll image. Tips- Hold middle mouse button to zoom. Select Click on the Select icon. Left

4

Zoom

Click on the Zoom icon. Left click and drag the mouse up to increase in size. Left click and drag the mouse down to decrease in size. Tips- Image zoom factor is denoted in the lower left corner of the image. To undo zoom, right click and select Zoom Factor- to fit, or choose Set Zoom from Main Menu. Hold middle mouse button to pan. Pan

Click on the Pan icon. Left click and drag to re-center or scroll image. Tips- Hold middle mouse button to zoom. Select

Click on the Select icon. Left click on an image to mark it as a key image. To select more than one image, use the left mouse button in conjunction with the control or shift key, the same as you would select multiple computer files-

To select nonadjacent images, hold CTRL while clicking each image. To select adjacent images, click on the first image, then hold SHIFT while clicking on the last image.

Tips- To deselect an image, hold CTRL and click on the image again. For more options, click on Select from the Main Menu.

Page 5: Open Internet Explorer to your Integrad® Website. · Left click and drag to re-center or scroll image. Tips- Hold middle mouse button to zoom. Select Click on the Select icon. Left

5

Navigator

Click on the Navigator icon.

• A thumbnail image representive of each series is displayed. • The active series is outlined in blue. • Displayed series are outlined in white. • Undisplayed series have no outline. • Double click on an undisplayed series to open the window. • Point the mouse over a thumbnail to display the series description. • Click and hold on a thumbnail to locate its position on the monitor by flashing. • Re-sort the order by clicking and dragging a series to the new position.

Click on this icon (upper left) to open the Layout Preview. Series in the thumbnail view can be dragged and dropped into open series window positions in the Layout Preview. Use this feature to quickly reorganize/move series about on the monitors by exchanging positions.

Page 6: Open Internet Explorer to your Integrad® Website. · Left click and drag to re-center or scroll image. Tips- Hold middle mouse button to zoom. Select Click on the Select icon. Left

6

Tips- When an exam is displayed that has additional series not provided for in the layout, Navigator opens automatically. Navigator can be resized by dragging its borders. If a scroll bar appears, it indicates there is additional information that can be viewed by scrolling or resizing. Film View

This icon toggles between Film View and Single Series View. Click on the Film View icon. Paging icons will appear on the toolbar. Images will be displayed in a multi-format.

Page 7: Open Internet Explorer to your Integrad® Website. · Left click and drag to re-center or scroll image. Tips- Hold middle mouse button to zoom. Select Click on the Select icon. Left

7

Click Page Format on the Main Menu to select a different matrix display. Use paging icons on the right end of the Main Toolbar to page through images.

First Page Fast Back Page Back Page Forward Fast Forward Last Page Tips- Page/Scroll options (as described above) also page while in Film View. Open the Navigator, click and drag thumbnails to re-sort the order. Click on Film View icon again to return to Single Series View. Cine Mode

Click the Cine button to activate, and a control bar opens at the bottom of the series. Use the ↑↓ arrows to set the frames per second. Use the ← → arrows to control the direction forward, backward, or bounce back and forth mode. Tips- Pointing the mouse at a control button to define its function.

Page 8: Open Internet Explorer to your Integrad® Website. · Left click and drag to re-center or scroll image. Tips- Hold middle mouse button to zoom. Select Click on the Select icon. Left

8

Click on the slider to advance to that area. Magnifying Glass

Click on the magnifying glass to activate, and then click on the area of interest. This will change to full 100% resolution (1.0 magnification) Tips- Click icon to toggle between off and on. Click and drag the corner of the ROI to resize the viewing area. Shortcuts- Hold shift key to drag zoom. Synchronize

Click icon to toggle linking off and on. Tips- For more linking options, go to “Synchronize” in the main menu bar. Absolute Position is the bed position from the scanner. Absolute Number is the image number from the scanner.

Page 9: Open Internet Explorer to your Integrad® Website. · Left click and drag to re-center or scroll image. Tips- Hold middle mouse button to zoom. Select Click on the Select icon. Left

9

Use Relative Position or Number to link prior exams while in comparison mode. Cross Reference

Click icon to toggle cross reference line off and on. Image Overlay

Click icon to toggle through the different preset slice information templates. Clicking the down arrow opens the menu to display all the overlay templates. Tip- For more slice information, right click on image and choose image info. Create Copy

Clicking on this icon creates a duplicate of the active series. Tip- Most useful for CT Abdomen, create duplicates for Lung, Liver, and Bone windows. Triangulation

Click icon to activate. Click on an area of interest, all other series (of unlike axis) will advance to that level and be marked by a

Page 10: Open Internet Explorer to your Integrad® Website. · Left click and drag to re-center or scroll image. Tips- Hold middle mouse button to zoom. Select Click on the Select icon. Left

10

green circle. Shortcut- While in paging mode, hold F2 to activate Triangulation. Tips- If a red circle appears, it indicates there are no corresponding slices at that level. Click and drag over an area of interest, the corresponding images will be displayed. Click and drag along a sagittal spine to move the axial series. Measurements 1 2 3 4 5

Click this icon to open the tool menu. 1. Measures distance point to point. 2. Measures angles. 3. Measures ROI (elliptical). 4. Measures a single point ROI. 5. Delete all measurements. Tips- Click and drag to define region of interest. Move the measurement annotation box by clicking and dragging. Click and drag the Point ROI tool (3) to obtain a roving Hounsfield measurement. Right click on angle measurement’s annotation box and choose “Ortho Angle” for orthopedic measurements. Right click over measurement to edit font and color. To delete a single object, double click on the highlighted annotation. To delete all objects from active image, click on recycle bin (6)

Page 11: Open Internet Explorer to your Integrad® Website. · Left click and drag to re-center or scroll image. Tips- Hold middle mouse button to zoom. Select Click on the Select icon. Left

11

Labels 1 2 3 4 5

Click this icon to select from the tool’s menu. 1. Annotate text. 2. Draw arrows. 3. Draw squares. 4. Draw circles. 5. Delete all annotations. Tip- To use text annotation, click on A (1), click on image, type text, and click green check. Drag text to desired location. Right click over annotation to edit font and color. Save Image

Click the save image icon to open the options dialogue. Select the file type and the folder in which to be saved. Notepad

Page 12: Open Internet Explorer to your Integrad® Website. · Left click and drag to re-center or scroll image. Tips- Hold middle mouse button to zoom. Select Click on the Select icon. Left

12

Click icon, always answer yes to security question. Click on Add Note, Add Internal Note, or Add Preliminary Report; type message, click done. Click red X in upper right corner to close. Tips- Notes and Reports are accessible from the patient list. They are color-coded and have 5 levels. If a notepad contains both notes and reports, the icon will be the color of the highest level.

1. Gray notepad is empty. 2. Light Yellow notepad indicates an Internal Note (viewable by all radiology personnel). 3. Dark yellow notepad indicates a Note (viewable by all users). 4. Light green notepad indicates a Preliminary Report. 5. Dark Green notepad indicates a Final Report.

Pop-Up Menu Some options are located in the Pop-Up Menu. (They may also appear in the Main Toolbar or Main Menu). To activate menu, right click over the image.

Page 13: Open Internet Explorer to your Integrad® Website. · Left click and drag to re-center or scroll image. Tips- Hold middle mouse button to zoom. Select Click on the Select icon. Left

13

Preset Window Click on Preset Window. Make a selection from the predefined list of Window/Level or choose to Invert black/white. Spine Labels

Page 14: Open Internet Explorer to your Integrad® Website. · Left click and drag to re-center or scroll image. Tips- Hold middle mouse button to zoom. Select Click on the Select icon. Left

14

Click on Spine Labels. Select level at which to start labeling; label type, labeling step, direction, and appearance settings. Click on image to deposit labels at desired levels. Tips- To remove labels or start over, click on Remove All. Close when done. Main Menu

Page 15: Open Internet Explorer to your Integrad® Website. · Left click and drag to re-center or scroll image. Tips- Hold middle mouse button to zoom. Select Click on the Select icon. Left

15

Zoom Factor Click on Set Zoom. Select the desired window size. Use the “to fit” option to resize the window to the original unzoomed size. Page Format Click on Page Format. Select the desired matrix display. Flip/Mirror/Rotate Flip for top to bottom; Mirror for left to right; Rotate turns image 90º. Done

The done button can be programmed to your own default setting, as follows: Click the down arrow to open the drop down menu. Click on Done Options, check off on desired options, click OK.

Page 16: Open Internet Explorer to your Integrad® Website. · Left click and drag to re-center or scroll image. Tips- Hold middle mouse button to zoom. Select Click on the Select icon. Left

16

Once the default is set, left click on the exit door icon when finished to close the study using the predefined done options, or click the down arrow to select from the menu. Comparisons

To compare a prior study: Select the studies for comparison by checking the boxes in the first column.

After checking two or more exams, click the scales icon . The most current study will open on the left display. The second most current will display on the right.

If more than two studies were originally selected, click on the unbalanced scales to display the list of studies. Click the L and R monitor position for the next two exams, then click Display.

Logout

Page 17: Open Internet Explorer to your Integrad® Website. · Left click and drag to re-center or scroll image. Tips- Hold middle mouse button to zoom. Select Click on the Select icon. Left

17

Click the logout button to end session. Notes- This will free the license for another user to login, if your facility has a limited number of licenses. The system administrator may set the auto logout for a predetermined inactivity timeout.


Recommended