Page 1: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

PALLADIOPELLET STOVES

Olanda

Scozia

Svizzera

Austria

Norvegia

Svezia

Danimarca

Germania

Page 2: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

Installation, operation and maintenance manualDear Customer,

We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l.. Please keep this manual safe along with your warranty certificate, and present it whenever a service engineer maintains your stove.

ALL OUR STOVES ARE LIT AND FULLY TESTED IN THE FACTORY.This introduction confirms the information provided in our offer for your Palladio stove. All our stoves are made from top quality materials and are lit and fully tested in our factory before they are despatched. If you see signs that your stove has already been used (such as pellets in the hopper or a dirty hearth), do not worry. This simply shows that we have tested your stove in our factory and found it to be fully functional and perfectly safe. You can therefore have every confidence in its efficiency and safety.

PALLADIO TECHNICAL ASSISTANCE CENTREIf your stove ever requires servicing, please ask your dealer to put you in touch with a qualified service engineer. Alternatively you can contact the Technical Assistance Centre of Edilvalli Arredi S.r.l. directly. We shall be happy to put you in touch with your local Technical Assistance Centre.

PALLADIO MEANS EFFECTIVENESS AND EFFICIENCY This manual provides important information and advice that will allow you to get the most from your new Palladio stove in terms of efficiency and safety. It also contains instructions for the regular maintenance of your stove.

RESPONSIBILITYEdilvalli Arredi S.r.l. declines all responsibility under civil and criminal law for damage or injury deriving from the failure to observe, in part or in whole, the instructions contained in this manual.Edilvalli Arredi S.r.l. declines all responsibility for damage or injury deriving from the improper use or incorrect operation of the stove by the purchaser, from unauthorised modifications and/or repairs, and from the use of non-original spare parts.Edilvalli Arredi S.r.l. declines all responsibility under civil or criminal law for damage or injury caused directly or indirectly by:

• inadequate maintenance• failure to observe the instructions contained in this manual• failure to observe all applicable safety precautions

• installation not conforming to applicable laws and standards in the country of installation• installation by unqualified and/or untrained personnel

• modifications and/or repairs performed without the manufacturer’s prior authorisation

• the use of non-original spare parts• exceptional events

Palladio majolica stoves – manufactured by Edilvalli Arredi S.r.l.

Dear Customer, We thank you for your choice of a Palladio stove from Edilvalli Arredi s.r.l..

• Please keep this manual safe along with the warranty certificate, and present it whenever a service engineer maintains your stove.

• Please remember that all our stoves are lit and fully tested in the factory.

TECHNICAL ASSISTANCE CENTREIf your stove ever requires servicing, please contact Edilvalli Arredi S.r.l. to obtain details of your local Technical Assistance Centre.

RESPONSIBILITYEdilvalli Arredi S.r.l. declines all responsibility under civil and criminal law for damage or injury deriving from the failure to observe, in part or in whole, the instructions contained in this manual.

Page 3: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

Edilvalli Arredi S.r.l. declines all responsibility for damage or injury deriving from the improper use or incorrect operation of the stove by the purchaser, from unauthorised modifications and/or repairs, and from the use of non-original spare parts.Edilvalli Arredi S.r.l. declines all responsibility under civil or criminal law for damage or injury caused directly or indirectly by:

• inadequate maintenance• failure to observe the instructions contained in this manual• failure to observe all applicable safety precautions• installation by unqualified and/or untrained personnel• installation not conforming to applicable laws and standards in the country of installation• modifications and/or repairs performed without the manufacturer’s prior authorisation• exceptional events

DECLARATION OF CONFORMITYEdilvalli Arredi s.r.l. hereby declares under its own responsibility that:the stove to which this manual relates (see nameplate) conforms to the requirements of the following directives:EN 1478589/106 EEC CPD73/23 EEC LVD98/37 EEC MACHINERY2004/108 EEC EMC

Page 4: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

GENERAL SAFETY PRECAUTIONS

WARNING!• Keep this manual safe along with the warranty certificate. Read all the instructions and technical information contained in

this manual thoroughly before installing the stove.

• Install the stove in conformity to all applicable local, national and European standards and legislation. When installing the stove, make sure that you conform to applicable standards and legislation governing the extraction of fumes to flues. The flue must have its outlet above roof height.

• Have an authorised technical assistance centre clean your stove and flue thoroughly once a year. Failure to comply with this requirements invalidates the warranty.

• The stove requires air to burn its fuel. An air intake must therefore be provided outside the room where the stove is installed in addition to a supplementary indirect air intake of at least 180 cm2.

• Bear in mind the weight of the stove when deciding where to position it. Make sure that the floor area where you intend to locate the stove is able to support its weight before commencing installation.

• If the floor is made from a flammable material (e.g. wood blocks or carpet), place a floor protector plate underneath the stove. (The floor protector plate must extend at least 25/30 cm beyond the perimeter of the stove.)

• For safety purposes, maintain a gap of at least 30 cm between the hot sides of the stove and any surrounding flammable materials (e.g. matchboard walls, wall paper, curtains). Alternatively, install suitable insulating materials. This precaution also applies if the stove is located near furniture like armchairs, etc.. Do not install the stove in restricted spaces unless suitable provision is made. Do not install the stove close up to walls as this can restrict the necessary air flow. Install the stove at least 3 cm away from all walls.

• It is essential for the flue to generate sufficient draught for the stove to function correctly. The partial or complete obstruction of the air intake to the hearth, or failure to keep the hearth properly clean can compromise the functioning of the stove. During lighting, for example, insufficient air supply will prevent the pellets from lighting properly and cause them to build up in the hearth. This can create excessive smoke in the combustion chamber. This in turn can lead to the spontaneous combustion of hot gases and a violent flame. If this occurs, do not open the door to the combustion chamber.

• Do not use flammable liquids to aid lighting of the pellet fuel.

• Do not touch the glass of the door when the stove is hot. Do not leave children unattended near the stove when it is lit. Hot parts can cause severe burns.

• Do not attempt to remove or move the majolica panels while they are hot, as this can cause them to break.

• Do not tamper with the stove. Perform only the operations specified in this manual to operate and maintain the stove. Refer all further servicing to an authorised service engineer. Disconnect the plug from the mains power socket before commencing any cleaning or maintenance.

• Always make quite sure that the door of the combustion chamber is properly closed and hermetically sealed during the lighting and normal functioning of the stove.

• Keep the door seal fully efficient at all times. If you notice any wear or damage to the seal, ask your local Technical Assistance Centre to replace it immediately.

• The automatic lighting of the pellet fuel is the most delicate stage in the operation of the stove. Keep the stove and the hearth thoroughly clean in order to ensure trouble-free lighting.

WARNING! Edilvalli Arredi S.r.l. reserves the right to introduce minor changes to the component parts of this product. Such changes may not be reflected in the contents of this manual. Edilvalli Arredi S.r.l. also reserves the right to introduce whatever changes it deems important to the functioning and appearance of the product. Purely aesthetic changes in the product with respect to the brochure are the result of the normal evolution and development of Palladio stoves.

Page 5: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

TRANSPORT• Stove models Austria, Svizzera and Olanda do not require any special procedures, apart from

normal care and attention during moving and handling.• Proceed as follows to move and handle the Norvegia model.

1. Carefully remove the packing.

2. Use the Allen key supplied to remove the four screws from the counter-frame, and remove the door.

3. Unwind the data cable from the display.

4. Move the combustion chamber to the place of installation.

5. Fit the pipes.6. Move the majolica body to the

place of installation.

7. Fit the door.

N.B.TAKE CARE NOT TO DAMAGE THE FLAT CABLE WHEN MOVING THE STOVE.

POSITIONING THE STOVE

It is extremely important to position the stove correctly. We recommend locating the stove in the most central point of the room you want to heat in order to ensure uniform heat distribution and maximum efficiency.The ideal location must also be near a flue. If the floor at the chosen position is made from flammable material (e.g. wood blocks or carpet), place a floor protector (ACCESSORY) over it.

TECHNICAL SPECIFICATIONS OF ROOM HEATING PELLET STOVES

OLANDACapacity of pellet hopper 12 KgEfficiency 91.00%Max. useful heat output 10 kWMax. autonomy 6 hPellet consumption 1 – 2.2 Kg/h Heatable room size Depends on building insulation Weight 98 KgMax. dimensions 54 x 43 x 110 cm (WxDxH)Dimensions of fume outlet Ø 80 mmDimensions of air intake Ø 40 mmDucting outlet Ø 60 mmElectrical power consumption 40 / 400 WattsCovering Top in majolica, sides in powder painted steel

alloyMains power protection FusesController protection Fuses

STANDARD EQUIPMENT• Room temperature sensor

• Fume temperature sensor• Weekly programmer-timer• 5-speed pellet feeder

• 5-speed fume extractor fan

• Heat exchanger fan• Ceramic glass door• Ash box

Page 6: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

• Infrared remote control (optional accessory - batteries not provided, 12V A23).

SCOZIACapacity of pellet hopper 10 KgEfficiency 91.00%Max. useful heat output 10 kWMax. autonomy 5 hPellet consumption 1 – 2.2 Kg/h Heatable room size Depends on building insulation Weight 98 KgMax. dimensions 71 x 20.5 x 109 cm (WxDxH)Dimensions of fume outlet Ø 80 mmDimensions of air intake Ø 40 mmElectrical power consumption 40 / 400 WattsCovering Sides in powder painted steel alloyMains power protection FusesController protection Fuses

STANDARD EQUIPMENT• Room temperature sensor• Fume temperature sensor• Weekly programmer-timer• 5-speed pellet feeder• 5-speed fume extractor fan• Heat exchanger fan• Ceramic glass door• Ash box

• Infrared remote control (optional accessory - batteries not provided, 12V A23).

SVIZZERACapacity of pellet hopper 13 KgEfficiency 91.00%Max. useful heat output 13 kWMax. autonomy 6.5 hPellet consumption 1 – 2.8 Kg/h Heatable room size Depends on building insulation Weight 130 KgMax. dimensions 66 x 45 x 115 cm (WxDxH)Dimensions of fume outlet Ø 80 mmDimensions of air intake Ø 40 mmDucting outlet Ø 60 mmElectrical power consumption 40 / 400 WattsCovering MajolicaMains power protection FusesController protection Fuses

STANDARD EQUIPMENT• Room temperature sensor• Fume temperature sensor• Weekly programmer-timer• 5-speed pellet feeder• 5-speed fume extractor fan• Heat exchanger fan• Ceramic glass door• Ash box

• Infrared remote control (batteries not provided, 12V A23).

AUSTRIACapacity of pellet hopper 15 Kg

Page 7: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

Efficiency 91.00%Max. useful heat output 13 kWMax. autonomy 6.5 hPellet consumption 1 – 2.8 Kg/h Heatable room size Depends on building insulation Weight 120 KgMax. dimensions 52 x 43 x 123 cm (WxDxH)Dimensions of fume outlet Ø 80 mmDimensions of air intake Ø 40 mmDucting outlet Ø 60 mmElectrical power consumption 40 / 400 WattsCovering Top, grille and lower covering in majolica, sides in

liquid painted steel alloyMains power protection FusesController protection Fuses

STANDARD EQUIPMENT• Room temperature sensor• Fume temperature sensor• Weekly programmer-timer• 5-speed pellet feeder• 5-speed fume extractor fan• Heat exchanger fan• Ceramic glass door• Ash box

• Infrared remote control (batteries not provided, 12V A23).

NORVEGIA – SVEZIA - DANIMARCACapacity of pellet hopper 23 KgEfficiency 91.00%Max. useful heat output 13 kWMax. autonomy 10 hPellet consumption 0.6 – 2.8 Kg/h Heatable room size Depends on building insulation Weight (Norvegia) 198 KgWeight (Svezia) 210 KgWeight (Danimarca) 230 KgMax. dimensions (Norvegia) 75 x 48 x 134 cm (WxDxH)Max. dimensions (Svezia) 75 x 48 x 133 cm (WxDxH)Max. dimensions (Danimarca) 98 x 60 x 138 cm (WxDxH)Dimensions of fume outlet Ø 80 mmDimensions of air intake Ø 40 mmElectrical power consumption 40 / 400 WattsCovering MajolicaMains power protection FusesController protection Fuses

STANDARD EQUIPMENT• Room temperature sensor• Fume temperature sensor• Weekly programmer-timer• 5-speed pellet feeder• 5-speed fume extractor fan• Heat exchanger fan• Ceramic glass door• Ash box

• Infrared remote control (batteries not provided, 12V A23).

GERMANIACapacity of pellet hopper 30 Kg

Page 8: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

Efficiency 91.00%Max. useful heat output 14.5 kWMax. autonomy 12 hPellet consumption 1 – 3.2 Kg/h Heatable room size Depends on building insulation Weight 250 KgMax. dimensions 98 x 48 x 147 cm (WxDxH)Dimensions of fume outlet Ø 80 mmDimensions of air intake Ø 40 mmDucting outlet Ø 60 mmElectrical power consumption 40 / 400 WattsCovering MajolicaMains power protection FusesController protection Fuses

STANDARD EQUIPMENT• Room temperature sensor• Fume temperature sensor• Weekly programmer-timer• 5-speed pellet feeder• 5-speed fume extractor fan• Heat exchanger fan• Ceramic glass door• Ash box

• Infrared remote control (batteries not provided, 12V A23).

INSTALLATION

• It is forbidden to install the stove in the following locations:- bedrooms and bathrooms- rooms already containing another heating appliance (fireplace, stove, etc.) that does not have its own independent air supply.

• Make sure that the electrical power socket is readily accessible.• Respect the minimum distances given below:

- Install the stove at least 50 mm away from all walls.- If the wall is made from flammable material, increase this distance to 150 mm (and insulate the wall with fireproof material).- Keep all furniture, curtains, and other flammable objects at least 400 mm away from the stove.

• If the stove has to be positioned on a wood floor, install it on a solid marble, ceramic or metal plate at least 2 mm thick. This plate must be at least 30 cm deeper than the stove and at least 15 cm wider than it.

CONNECTING THE STOVE TO THE ELECTRICITY SUPPLYBefore connecting the stove to the mains electricity supply, make sure that the power socket is in good condition and that it has an efficient earth (ground) connection.Make sure that the mains power cable and room temperature sensor cable do not come into contact with hot parts of the stove, e.g. the flue, and that they are not crushed by the stove, as this could lead to short circuits.NOTE – The stove’s electrical system is protected by fuses. Disconnect the stove from the mains power supply before commencing any maintenance or checks!

THE FLUEBefore commencing the installation, make sure that the inside diameter of the flue and the height of the terminal are sufficient to create an adequate draught. Also check that the flue is correctly installed and not blocked. Connecting the stove to the flue is an important operation that can compromise the functioning of the stove if not done correctly. It should therefore always be done or checked by a competent and qualified technician. Do not attempt “do-it-yourself” installations, especially if you do not have the necessary knowledge or experience. It is particularly important to use flue pipes that are suitable for pellet stoves and that have the proper seals.

Page 9: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

NOTE – The pipes making up the flue must not, at any point, be smaller in diameter than the fume outlet on the stove. To ensure the correct functioning of the stove, avoid horizontal sections of flue as these can fill up with ash and reduce the draught. In the same way, avoid too many bends in the pipes to ensure safe fume extraction with no loss of draught. (The complete flue should have no more than 2 bends, which must be securely fixed.)

aria per la combustione prelevata dall’esterno

Comburent air drawn from outdoors

canna fumaria in muratura Masonry chimneyProtezione isolante canna fumaria inter. H. min 200 cm

Protective insulation around indoor section of flue, min H. = 200 cm

Installation without existing chimney Installation with existing chimney

FLUE CALCULATION TABLE FOR PELLET STOVES

Page 10: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

Type of stove

Type of flue Height and protrusion

Stoves of up to 13 kW heat output

Fig 1Da H 200cm = 0,5 – 1,5 80A H 600cm = 1,5 – 3,0 100

Fig. 2Da H 200cm = 0,5 – 1,5 80A H 600cm = 1,5 – 3,0 80

Fig. 3Da H 200cm = 0,5 – 1,5 80A H 600cm = 1,5 – 3,0 100

Fig. 4Da H 200cm = 0,5 – 1,5 80A H 600cm = 1,5 – 3,0 100

Fig. 1Da H 600cm = 0,5 – 1,5 100A H 1200cm = 1,5 – 3,0 120

Fig. 2Da H 600cm = 0,5 – 1,5 80A H 1200cm = 1,5 – 3,0 100

Fig. 3Da H 600cm = 0,5 – 1,5 100A H 1200cm = 1,5 – 3,0 120

Fig. 4Da H 600cm = 0,5 – 1,5 100A H 1200cm = 1,5 – 3,0 120

Fig. 1Da H 1200cm = 0,5 – 1,5 120A H 1800cm = 1,5 – 3,0 140

Fig. 2Da H 1200cm = 0,5 – 1,5 80A H 1800cm = 1,5 – 3,0 100

Fig. 3Da H 1200cm = 0,5 – 1,5 120A H 1800cm = 1,5 – 3,0 140

Fig. 4Da H 1200cm = 0,5 – 1,5 120A H 1800cm = 1,5 – 3,0 140

Fig. 5

Please bear in mind that the values given in the above table are intended only as guidelines to help the installer evaluate the necessary dimensions of the flue pipes. It does not represent any specific standard or directive. If there is an existing flue already in place, make sure that its pipes are clean and tightly sealed. In the case of an existing masonry chimney, connect the fume outlet from the stove to this, and install an inspection door in an accessible position to facilitate checking and cleaning.

INSTALLING THE FLUEFig. 1 – Installation without a masonry chimney. Ø 80 pipe: layout with one 90° bend.The first, horizontal section of flue runs directly to the outside of the building. The second, vertical section of flue (complete with wind cowl) runs completely outside the building. Use double wall pipes to prevent the formation of condensation inside the flue. As shown in the figure, the vertical section of flue (the stack) must terminate above the roof. This is a legal requirement. The higher the end of the pipe, the more efficient the stove.

11Fig. 2 - Installation with a masonry chimney with terminal above the roof. Ø 80 pipe: layout with one 90° bend.The first, horizontal section of flue connects to the existing internal or external masonry chimney. If the stove has to be connected to a masonry chimney, or if there is an existing flue but this is too large in size, route steel flue pipes of no less than Ø 80 mm up through it. The wind cowl must terminate higher than the apex of the roof.

INSTALLING THE COMBURENT AIR PIPEThe following instructions are valid for figures 1 and 2.

Page 11: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

Two alternative installations are possible for both types of flue installation:1. Air can be drawn from outdoors through a pipe connected to the air inlet at the rear of the

stove. This is the recommended method as it prevents fumes and smells from escaping into the room.

2. Air can be drawn directly from the room where the stove is installed. If this option is preferred, you must install an air vent of at least 180 cm² through an outside wall near the stove. It is possible that you might detect a slight smell of burned wood in the house if comburent air is drawn from the room itself.

NOTE – In either case, check regularly that the passage of air is not restricted or blocked in any way. Protect the air inlet with a suitable grille and check it at regular intervals.

Important points:• The air intake must be of adequate dimensions.• Horizontal sections of flue must have a slope of > 5° and a length of < 2 metres.• The vertical section of flue (the stack) must have a height of > di 2 metres.• There must be provision for inspecting all sections of the flue.

• Mastic or a high temperature sealant should be used to seal the flue at the point where it connects to the stove’s fume outlet.

• Provide a drain point for condensate and ash.NOTE - Never connect the flue from this stove to a flue for another stove or fireplace, etc..

PELLET FUELPellet fuel comes in the form of small cylindrical pellets of about 6 mm in diameter. These are made from compressed sawdust and waste wood chippings, with no additives, colouring agents or other materials.Technical specifications of wood pellets:• diameter: 6 – 6.5 millimetres• maximum length: 20-25 mm• maximum humidity: 8%• calorific value: approx. 4,800 kcal/kg.NOTE – The use of pellets with different specifications to those given above may reduce the heat output of the stove, lead to the formation of residues, cause poor combustion, and even make it necessary to recalibrate the stove's parameters. The manufacturer cannot guarantee the proper functioning of the stove if pellets with specifications other than those given above are used as fuel.

CLEANINGProper cleaning and maintenance are essential to the correct functioning of the stove. Failu re to respect the following instructions invalidates the warranty.• Ordinary daily cleaning to be performed by the user (before lighting the stove, while it is still

cold):- Open the door and vacuum clean the fire box. - Remove the hearth, clean it and make sure that the holes in it are not blocked.

- Vacuum clean the hearth compartment, clean all contact edges and fit the hearth again, ensuring that it is seated securely.- Empty the ash box, if fitted.

Page 12: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

- Clean the glass with a damp cloth (only when the stove is cold).- Carefully close the door.

• Extraordinary annual cleaning to be performed by the service engineer:- Perform general cleaning of the inside and outside of the stove’s flue pipes.- Remove the furnace linings, and thoroughly clean and decoke the hearth and hearth compartment.- Clean the fans, check them for play and check their mountings.- Clean, inspect and decoke the glow plug igniter and its housing.- Check the door seal and replace if necessary.- Clean the display.- Inspect the electrical control cables and connections and the mains power cable.- Clean the pellet hopper and check the feed screw and gearmotor for play.- Check the functioning of the feed screw, fill the hopper and check the stove lighting sequence.- Inspect and clean the fume outlet.- Inspect the flue and check the draught. Clean the flue or instruct the user to have it cleaned if

necessary.

NOTE – The glow plug igniter and the hearth compartment are both subject to wear. Check and replace if necessary.

STARTING UP ROOM HEATING STOVES

The control panel incorporates a display that shows information on the functioning of the stove. When the stove is first switched on, before lighting occurs, the display appears as shown in Fig. 6.

Fig. 6

orologio Clocktemperatura ambiente Room temperature

spento Offstato Status

dialogo Display messagepotenza Heat output level

The control panel provides a menu via which you can view and set functioning parameters (depending on your access level). All control keys have a number to identify them.

Fig. 7crono Timer

candeletta Igniter

Page 13: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

coclea Feed screwaspiratore fumi Fume extractor fan

scambiatore Heat exchanger fannon usato Not used

allarme Alarm

Fig. 7 shows the meaning of the status indicators on the left of the display.When a status indicator lights up, it shows that the device corresponding to it is functioning.

SWITCHING THE STOVE ON

To switch the stove on, press and hold key (4) (the ON/OFF key) for a few seconds. See Fig. 8. Press and hold the same key again to switch the stove off. The complete functioning cycle comprises five separate stages (lighting, flame stabilisation, normal functioning, economy functioning and shutdown). The stove switches between these stages on the basis of fume temperature and parameter settings.

Fig.8orologio Clock

temperatura ambiente Room temperaturedialogo Display messagepotenza Heat output level

LIGHTING THE STOVELighting begins when the glow plug igniter is switched on and the feed screw charges pellets into the stove. The display reads out, in succession, the messages “CLEANING HEARTH”, “LIGHTING”, “CHARGING PELLETS” and “WAITING FOR FLAME”. After about 45 seconds, the feed screw stops and the fume extractor fan starts (at the predefined speed for this stage). As soon as the pellet fuel starts to burn, and fume temperature reaches 50 C°, the glow plug igniter switches off and the stove controller switches to the flame stabilisation stage. The lighting stage finishes when fume temperature reaches 50 C°, but the functioning time of the glow plug igniter is limited to a maximum of 15 minutes for safety reasons and to prevent damage. If the pellet fuel has not lit within this 15 minute period, the display reads out the alarm message “LIGHTING FAILED”.

timer Timertemperatura ambiente Room temperature

dialogo Display messagepotenza Power output level

Fig. 9

Page 14: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

FLAME STABILISATIONDuring flame stabilisation the feed screw charges pellets into the stove at the predetermined speed for this stage. When fume temperature exceeds 100 C°, the stove’s controller switches to normal functioning mode. During flame stabilisation, the fume extractor fan runs at the predetermined speed for the stage. Provided temperature remains stable for a predetermined period of time, the stove’s controller switches to normal functioning mode. You can bypass the start-up stages by pressing and holding the increase power key (6) for about 3 seconds. This forces the stove directly into normal functioning mode.

NORMAL FUNCTIONING

The stove’s controller provides an input for a room thermostat. Depending on the settings made on the room thermostat and on actual room temperature, the stove can function on a number of ways:- T amb: this is the temperature measured by the room temperature sensor.- T setAmb: this is the temperature set on the room thermostat.- T setTerm: this is the setting of the ROOM TEMPERATURE SETPOINT.Room thermostat closed (Tamb >TsetTerm): the display reads out the message “ton” and the stove runs at the predetermined power setting until the thermostat opens.Room thermostat open (TAmb>TsetTerm): the stove runs at the predetermined power setting until TsetTerm temperature is reached (Tamb<TsetTerm), and then switches to economy mode.

Fig. 10

orologio Clocktemperatura ambiente Room temperature

dialogo Display messagepotenza Heat output level

TEMPERATURE MODULATION

The stove enters temperature modulation mode if room temperature reaches the value set in the “TEMPERATURE SETTING”. In temperature modulation mode, the feed screw, the fume extractor fan and the heat exchanger fan all run at minimum speed and the display reads out the message “MODULATING MODE”.

Fig . 11

Page 15: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

SHUTDOWN

To shut down the stove, press and hold the ON/OFF key (4) for a few seconds. The feed screw stops, the fume extractor fan slows to the predetermined speed, and the display reads out the message “FINAL CLEANING”. When fume temperature falls to the minimum functioning threshold, the heat exchanger fan switches off. Then, after a delay of about 10 minutes, the fume extractor fan also stops.

Fig. 12

RE-LIGHTING THE STOVE

You cannot re-light the stove until fume temperature falls below the value set in parameter Pr13 (about 50°) and the safety time set in parameter Pr38 (about 10 minutes) has also passed.

ALARM SIGNALLING

If any malfunction occurs, an alarm message appears on the display. The following is a list of the alarm messages that can appear.

MESSAGE ON DISPLAY DESCRIPTION OF ALARM

1. FUME TEMP. ALARM Fume temperature sensor malfunction

2. ALARM HOT TEMP.Fume overtemperature

3. LIGHTING FAILUREThe lighting stage has failed

4. LIGHTING FAILUREThe stove has gone out during normal functioning

5. ALARM BLACKOUT Mains power failure

6. ALARM DEP FAIL Safety pressure switch error

7. ALARM SIC FAILGeneral safety thermostat alarm

8. ALARM FAL FAIL Extractor fan malfunction

Fig. 13

NOTE – All alarm conditions cause the immediate shutdown of the stove.An alarm status is signalled after the delay set in parameter Pr11. Alarm status can be reset by pressing key (4). Switch off the stove, ascertain what is causing the alarm, eliminate the cause, and then light the stove again. If the alarm occurs again, contact your Technical Assistance Centre.

1. FUME TEMPERATURE SENSOR ALARM

This alarm shows that the fume temperature sensor is malfunctioning. The stove initiates the shutdown procedure if this alarm occurs.

2. FUME OVERTEMPERATURE ALARM

Page 16: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

This alarm shows that the fume temperature sensor has detected a temperature in excess of 250°C. The display reads out the message shown in Fig. 14.

Fig. 14

3. LIGHTING FAILURE ALARM

This alarm shows that the lighting stage has terminated without the fuel lighting.

Fig. 15

4. FLAME OUT DURING NORMAL FUNCTIONING ALARM

This alarm shows that the stove has gone out and that fume temperature has dropped below the minimum operating threshold (parameter Pr13) during the course of normal functioning.

5. DRAUGHT SAFETY SWITCH ALARM

If the draught in the flue falls to a level below the minimum operating threshold, the draught (negative pressure) safety switch trips. This stops the feed screw (since it is wired in series with the feed screw gearmotor) and at the same time informs the controller of the stoppage via pin AL2 of connector CN4. The display reads out “Alarm Dep Fail” and the stove shuts down.

6. GENERAL SAFETY THERMOSTAT ALARM (depending on model)

If temperature in the flue rises above the maximum operating threshold, the general safety thermostat trips. This stops the feed screw (since it is wired in series with the feed screw gearmotor) and at the same time informs the controller of the stoppage via pin AL1 of connector CN4. The display reads out “Alarm Sic Fail” and the stove shuts down.

7. EXTRACTOR FAN MALFUNCTION ALARM

(depending on model)

A malfunction of the fume extractor fan shuts down the stove and displays the “Alarm Fal Fail”. The appearance of this alarm initiates the shutdown procedure immediately.

MENUPress the MENU key (3) to access the menu.

Page 17: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

The menu contains various levels and functions through which you can access settings and program the controller. To access the menu, press and hold the menu key (3) key for two seconds, then press keys (5) and (6) to scroll through the sub-menus. When you reach the sub-menu you want, press key (3) again to confirm your selection.

• 01 FAN SETTINGS MENU• 02 CLOCK MENU• 03 TIMER MENU• 04 LANGUAGE MENU• 05 STANDBY MENU• 06 BUZZER MENU• 07 INITIAL CHARGING MENU

• 08 MODE MENU

• 09 PARAMETERS MENU02 - CLOCK MENU

This menu lets you set the current time and date. The controller is fitted with a lithium battery that gives the internal clock an autonomy of 3 to 5 years.

input User inputlivello di menu Menu level

dialogo Display message

Fig. 16Go to the CLOCK menu and press keys (5) and (6) to scroll through the values. Press key (3) to confirm your settings.

03 - TIMER MENUSub-menu 03 - 01 – Enable timerThis sub-menu lets you enable and disable timer-programmer functions in general.

Fig. 17

Sub-menu 03 - 02 – Daily programmingThis sub-menu lets you enable, disable and set the daily timer-programmer.

Page 18: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

You can create two time bands starting and ending at the times you enter, as shown in the table below. The OFF setting instructs the timer-programmer to ignore the parameter.

Fig. 18

Fig. 19

Selection Meaning Possible valuesSTART 1 Start-up time Time - OFFSTOP 1 Shutdown time Time - OFFSTART 2 Start-up time Time - OFFSTOP 2 Shutdown time Time - OFF

Sub-menu 03 - 03 – Weekly programmingThis sub-menu lets you enable, disable and set the weekly timer-programmer.

Fig. 20

input User inputlivello di menu Menu level

dialogo Display messagestato Status

The weekly timer-programmer provides 4 independent weekly programs. The effect of these depends on how the 4 time band settings are programmed. You can enable or disable the weekly timer-programmer. If you enter an OFF setting in a time field, the timer ignores the field.

Page 19: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

Fig. 21

PROGRAMMA 1 PROGRAM 1livello di menu Menu levelselezione Selectionsignificato Meaningvalori possibili Possible valuesSTART PROG 1 START PROG 1STOP PROG 1 STOP PROG 1LUNEDI’ PROG 1 MONDAY PROG 1MARTEDI’ PROG 1 TUESDAY PROG 1MERCOLEDI’ PROG 1 WEDNESDAY PROG 1GIOVEDI’ PROG 1 THURSDAY PROG 1VENERDI’ PROG 1 FRIDAY PROG 1SABATO PROG 1 SATURDAY PROG 1DOMENICA PROG 1 SUNDAY PROG 1ora di attivazione Start-up timeora di disattivazione Shutdown timegiorno di riferimento Day applicableora/OFF Time - OFFon/off On/Off

NOTE – Take special care when programming to avoid overlapping start-up and shutdown times for different programs on the same day.

Sub-menu 03 - 04 – Weekend programming

This sub-menu lets you enable, disable and set timer-programmer functions for weekends (days 6 and 7,i.e. Saturday and Sunday).

Fig. 22NOTE – In order to avoid confusion and unwanted start-ups and shutdowns, set just one time band for weekends unless you know exactly what time bands you require.

If you wish to apply the weekly program on weekends too, simply disable the weekend program. Keep the weekend program disabled to use weekday programs 1, 2, 3 and 4.

Page 20: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

Deactivate the weekly program before activating the weekend program.

04 – LANGUAGE MENU

This menu lets you select the display language from a list of available languages.

Fig. 23

05 – STANDBY MENU

This menu lets you activate “STANDBY” mode. In standby mode, the stove shuts down if room temperature remains above the temperature setpoint for a time in excess of that set in parameter Pr44.

If the stove shuts down under these conditions, you can only re-light it when the following condition occurs:

TSET < (Tambient – Pr43)

06 - BUZZER MENU

If this function is turned “OFF”, the buzzer is disabled.

07 - INITIAL CHARGING MENU

When the stove is shut down and cold, this menu lets you load a charge of pellets for a time of 4 seconds. Press key (1) to start charging and press key (4) to stop charging. Only use this function if the hopper has run out and has been refilled.

Fig. 24

CHANGING THE ROOM TEMPERATURE SETPOINT

Press keys (1) and (2) to change the room temperature setpoint. The display shows the current temperature setpoint.

Page 21: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

Fig. 25 valore impostato Temperature setting

CHANGING HEAT OUTPUT

Press keys (5) and (6) to decrease or increase the stove’s heat output. All related functions are updated automatically. The display shows the heat output selected. If the temperature measured by the room temperature sensor exceeds the temperature setpoint on the display, the controller automatically reduces heat output to the minimum setting (level 1).

Fig. 26

MODE MENU

The mode menu determines how the stove functions. The stove can function in one of two modes:• manual: the stove functions continuously. In manual mode, press the ON/OFF key to light and

shut down the stove. • automatic: the controller lights and shuts down the stove automatically in accordance with

the weekly programme (see the weekly programme menu).

Press the ENTER key to confirm your settings, or press the function key to cancel them. Once you have entered a setting, the stove display returns to the main menu.You can switch between manual and automatic mode by pressing the relevant key on the display.

THE INFRARED REMOTE CONTROL

You can use the remote control to light and shut down the stove, change the room temperature setpoint and change heat output. The remote control cannot be used to change any other parameters.You can enable and disable the remote control using the remote control function in the parameters menu.

Page 22: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

Using the remote control:− Press the two + keys (1 and 6) simultaneously to light and shut down the stove.− Press the left hand + and – keys with the thermometer symbol (1 and 2) to increase or

decrease the room temperature setpoint.− Press the right hand + and – keys with the flame symbol (5 and 6) to increase or decrease the

stove’s heat output.

TROUBLESHOOTINGDisplay blank and keys not working.

No mains power or control panel cable not properly connected.

Check that the mains power cable and the control panel cable are properly connected.

Remote control not working. 1. Too far away from stove.

2. Batteries discharged.

1. Move closer to the stove.

2. Check the batteries and change if necessary.

The stove will not light.ALARM 5.

Too much fuel in the hearth.

Clean out the hearth (see the “Cleaning” section).

The stove does not light automatically.

ALARM 5.

The glow plug igniter is not getting hot.

The glow plug igniter is damaged or worn out.

No pellets coming down the chute.

Check the electrical wiring and fuses.Check the glow plug igniter and replace if necessary (operation reserved for Technical Assistance).

Check the glow plug igniter and replace if necessary (operation reserved for Technical Assistance).

!! Disconnect the stove from the mains electricity supply before commencing!

Check that the pellets are not jammed on the chute.Check that the feed screw is not jammed.Check the door seal and replace if necessary.

The stove shuts down.

ALARM 5.

1. The stove has functioned for a long time without the hearth being cleaned.

2. The pellet hopper is empty.

3. The feed screw is not charging pellets.

1. Clean the hearth.2. Check the hopper and refill if necessary.

3. Fill the feed screw (see “Starting up room heating stoves”).

Air from the stove is not warm. Too much soot in the flue pipes.

Clean the flue pipes (operation reserved for Technical Assistance) and update the fan control parameters.

Page 23: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

Display blank and keys not working.

No mains power or control panel cable not properly connected.

Check that the mains power cable and the control panel cable are properly connected.

The stove becomes clogged quickly and combustion is uneven.

The flue is too long or twisted.

The pellets are damp.

The hearth has been charged with too many pellets.

Wind is blowing into the stove from outdoors.

Insufficient air is getting to the hearth.

The flue is blocked.

The type of pellet fuel has changed.

Adjust comburent air flow.

Check the pellets.

Gradually reduce pellet feed in the “Parameters” menu (operation reserved for Technical Assistance).

Fit a wind-proof flue terminal.

Check that the hearth and comburent air duct are both clean and correctly positioned.Check all the seals and check the flue for cleanliness.

Clean as necessary.

Reduce pellet feed in the “Parameters” menu. If the problem persists, contact Technical Assistance.

The stove shuts down for lack of pellets.

PELLETS FINISHED ALARM.

The feed screw is malfunctioning.

The temperature setpoint has been reached.

!! Disconnect the stove from the mains electricity supply before commencing!

- Remove any blockages from the feed screw.- Remove any blockages from the chute.- Remove any pellet dust from the bottom of the hopper.

This is normal functioning. The stove will return to full power when room temperature falls.

STOVE CONTROLLER ELECTRICAL BLOCK DIAGRAM

Page 24: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

TRASFORMATORE TRANSFORMERDISPLAY DISPLAY CONNECTORSERIALE SERIAL CONNECTORCRONO TIMERFILTRO DI RELè RELAY FILTERFUS FUSEENCODER ENCODER SONDE AMBIENTE ROOM TEMPERATURE SENSORTERMOSTATO SUPPLEMENTARE SUPPLEMENTARY THERMOSTATSONDA FUMI FUME TEMPERATURE SENSORENCODER ENCODER SCAMBIATORE SECONDARIO N.2 SECONDARY HEAT EXCHANGER N.2TERRA EARTH (GROUND)RETE MAINSVENTILATORE FUMI EXTRACTOR FANSCAMBIATORE PRINCIPALE MAIN HEAT EXCHANGER COCLEA FEED SCREWCANDELETTA GLOW PLUG IGNITERALF= Termostato Sicurezza generale ALF = General safety thermostat ALC = Depressimetro ALC = Draught pressure switchALP = Temostato Sicurezza Vano Pellet ALP = Pellet compartment safety thermostat(*) Vedi paragrafo corrispondente per il corretto utilizzo

(*) See the relevant instructions for correct operation.

Page 25: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

Palladio majolica stovesEdilvalli Arredi S.r.l.

Via Oselin, s.n.33047 Remanzacco (UD) - Italy

tel. 0432/1744006 fax 0432/[email protected]

Page 26: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

MODULO 1° COLLAUDO

La presente scheda deve essere compilata a cura del tecnico Palladio al momento del primo collaudo.

DATI del CLIENTE DATA COLLAUDO

COGNOME/NOME

MODELLO

MATRICOLALUNGHEZZA

PELLET

PARAMETRO DESCRIZIONE

TARA

TURE

TEC

NIC

O

TARA

TURE

FA

BBRI

CA

Pr01 M-9-7-01 Tempo massimo del ciclo di accensione minutoPr02 M-9-7-02 Tempo di avvio minutoPr03 M-9-7-03 Intervallo di tempo tra le due pulizie del braciere secondoPr04 M-9-7-04 Tempo di ON motore coclea nella fase di accensione secondoPr05 M-9-7-05 Tempo di ON motore coclea nella fase di avvio secondoPr06 M-9-7-06 Tempo di ON motore coclea nella fase di lavoro a potenza 1 secondoPr07 M-9-7-07 Tempo di ON motore coclea nella fase di lavoro a potenza 2 secondoPr08 M-9-7-08 Tempo di ON motore coclea nella fase di lavoro a potenza 3 secondoPr09 M-9-7-09 Tempo di ON motore coclea nella fase di lavoro a potenza 4 secondoPr10 M-9-7-10 Tempo di ON motore coclea nella fase di lavoro a potenza 5 secondoPr11 M-9-7-11 Ritardo allarmi secondoPr12 M-9-7-12 Durata pulizia braciere secondoPr13 M-9-7-13 Temperatura minima fumi per considerare la stufa accesa C°Pr14 M-9-7-14 Soglia di allarme temperatura massima C°Pr15 M-9-7-15 Soglia di temperatura fumi per accendere gli scambiatori C°Pr16 M-9-7-16 Velocità aspirazione fumi nella fase di accensione voltPr17 M-9-7-17 Velocità aspirazione fumi nella fase di avvio voltPr18 M-9-7-18 Velocità aspirazione fumi nella fase di lavoro a potenza 1 voltPr19 M-9-7-19 Velocità aspirazione fumi nella fase di lavoro a potenza 2 voltPr20 M-9-7-20 Velocità aspirazione fumi nella fase di lavoro a potenza 3 voltPr21 M-9-7-21 Velocità aspirazione fumi nella fase di lavoro a potenza 4 voltPr22 M-9-7-22 Velocità aspirazione fumi nella fase di lavoro a potenza 5 voltPr23 M-9-7-23 Velocità motore scambiatore 1 nella fase di lavoro a potenza 1 voltPr24 M-9-7-24 Velocità motore scambiatore 1 nella fase di lavoro a potenza 2 voltPr25 M-9-7-25 Velocità motore scambiatore 1 nella fase di lavoro a potenza 3 voltPr26 M-9-7-26 Velocità motore scambiatore 1 nella fase di lavoro a potenza 4 voltPr27 M-9-7-27 Velocità motore scambiatore 1 nella fase di lavoro a potenza 5 voltPr28 M-9-7-28 Temperatura fumi per passare in modalità ECO-MODULA °CPr29 M-9-7-29 Velocità aspirazione fumi nella fase di pulizia braciere voltPr30 M-9-7-30 Tempo di ON motore coclea nella fase di pulizia secondoPr31 M-9-7-31 Abilitazione encoder -Pr32 M-9-7-32 Tempo frenatura coclea secondoPr33 M-9-7-33 Tempo Pulizia Iniziale secondoPr34 M-9-7-34 Tempo preriscaldamento secondoPr35 M-9-7-35 Velocità fumi pulizia iniziale voltPr36 M-9-7-36 Velocità fumi preriscaldamento voltPr37 M-9-7-37 Velocità fumi attesa volt

TARA

TURE

VA

RIE

Pr38 M-9-5-01 Blocco riaccensione minutoPr39 M-9-5-02 Tempo di spegnimento aspiratore fumi minutoPr40 M-9-5-03 Tempo di precaria in accensione secondoPr41 M-9-5-04 Tempo di attesa dopo precarica secondoPr42 M-9-5-05 Velocità aspiratore fumi in fase di precarica voltPr43 M-9-5-06 Isteresi temperatura ON/OFF in modalità automatica °CPr44 M-9-5-07 Ritardo allo spegnimento in modalità automatica minutoPr45 M-9-5-08 Ritardo cambio potenza secondoPr46 M-9-5-09 Abilitazione comando del remoto -Pr47 M-9-5-10 Abilitazione blocco tastiera -Pr48 M-9-5-11 Riaccensione automatica dopo black-out secondo

ESSENZA PELLET

LIVELLO DI MENU'

UNITA' MISURA

VALORIIMPOSTATI

Page 27: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

MODULO 1° COLLAUDO COMMISSIONING FORMLa presente scheda deve essere compilata a cura del tecnico Palladio al momento del primo collaudo.

This form must be compiled by the Palladio engineer on commissioning of the stove.

DATI del CLIENTE DETAILS OF PURCHASER DATA COLLAUDO COMMISSIONING DATECOGNOME/NOME NAME/SURNAMEMODELLO MODELMATRICOLA SERIAL NUMBERESSENZA PELLET PELLET TYPELUNGHEZZA LENGTHTARATURE TECNICO TECHNICAL SETTINGSTARATURE VARIE VARIOUS SETTINGSTARATURE FABBRICA FACTORY SETTINGSPARAMETRO PARAMETER LIVELLO DI MENU’ MENU LEVELDESCRIZIONE DESCRIPTIONUNITA’ MISURA UNIT OF MEASUREMENTVALORI IMPOSTATI SETTING VALUESminuto minutesecondo secondVOLT VoltC° C°Pr01 Tempo massimo del ciclo di accensione Pr01 Lighting cycle timeout Pr02 Tempo di avvio Pr02 Start-up time Pr03 Intervallo di tempo tra le due pulizie del braciere Pr03 Hearth cleaning interval Pr04 Tempo di ON motore coclea nella fase di accensione

Pr04 Feed screw ON time during lighting

Pr05 Tempo di ON motore coclea nella fase di avvio Pr05 Feed screw ON time during start-up Pr06 Tempo di ON motore coclea nella fase di lavoro a potenza 1

Pr06 Feed screw ON time during normal functioning at level 1

Pr07 Tempo di ON motore coclea nella fase di lavoro a potenza 2

Pr07 Feed screw ON time during normal functioning at level 2

Pr08 Tempo di ON motore coclea nella fase di lavoro a potenza 3

Pr08 Feed screw ON time during normal functioning at level 3

Pr09 Tempo di ON motore coclea nella fase di lavoro a potenza 4

Pr09 Feed screw ON time during normal functioning at level 4

Pr10 Tempo di ON motore coclea nella fase di lavoro a potenza 5

Pr10 Feed screw ON time during normal functioning at level 5

Pr11 Ritardo allarmi Pr11 Alarm delayPr12 Durata pulizia braciere Pr12 Hearth cleaning durationPr13 Temperatura minima fumi per considerare la stufa accesa

Pr13 Minimum fume temperature for stove to be considered lit

Pr14 Soglia di allarme temperatura massima Pr14 Maximum alarm temperature threshold Pr15 Soglia di temperatura fumi per accendere gli scambiatori

Pr15 Fume temperature threshold for starting heat exchangers

Pr16 Velocità aspirazione fumi nella fase di accensione Pr16 Fume extractor fan speed during lightingPr17 Velocità aspirazione fumi nella fase di avvio Pr17 Fume extractor fan speed during start-upPr18 Velocità aspirazione fumi nella fase di lavoro a potenza 1

Pr18 Fume extractor fan speed during normal functioning at level 1

Pr19 9 Velocità aspirazione fumi nella fase di lavoro a potenza 2

Pr19 Fume extractor fan speed during normal functioning at level 2

Pr20 Velocità aspirazione fumi nella fase di lavoro a potenza 3

Pr20 Fume extractor fan speed during normal functioning at level 3

Pr21 Velocità aspirazione fumi nella fase di lavoro a potenza 4

Pr21 Fume extractor fan speed during normal functioning at level 4

Pr22 Velocità aspirazione fumi nella fase di lavoro a potenza 5

Pr22 Fume extractor fan speed during normal functioning at level 5

Pr23 Velocità motore scambiatore 1 nella fase di lavoro a potenza 1

Pr23 Heat exchanger fan speed during normal functioning at level 1

Pr24 Velocità motore scambiatore 1 nella fase di lavoro Pr24 Heat exchanger fan speed during normal

Page 28: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

a potenza 2 functioning at level 2Pr25 Velocità motore scambiatore 1 nella fase di lavoro a potenza 3

Pr25 Heat exchanger fan speed during normal functioning at level 3

Pr26 Velocità motore scambiatore 1 nella fase di lavoro a potenza 4

Pr26 Heat exchanger fan speed during normal functioning at level 4

Pr27 Velocità motore scambiatore 1 nella fase di lavoro a potenza 5

Pr27 Heat exchanger fan speed during normal functioning at level 5

Pr28 Temperatura fumi per passare in modalità ECO-MODULA

Pr28 Fume temperature for switching to eco-modulating mode

Pr29 Velocità aspirazione fumi nella fase di pulizia braciere

Pr29 Fume extractor fan speed during hearth cleaning

Pr30 Tempo di ON motore coclea nella fase di pulizia Pr30 Feed screw ON time during hearth cleaningPr31 Abilitazione encoder Pr31 Encoder enablingPr32 Tempo frenatura coclea Pr32 Feed screw slowing timePr33 Tempo Pulizia Iniziale Pr33 Initial cleaning timePr34 Tempo preriscaldamento Pr34 Preheating time Pr35 Velocità fumi pulizia iniziale Pr35 Fume extractor fan speed during initial cleaningPr36 Velocità fumi preriscaldamento Pr36 Fume extractor fan speed during lightingPr37 Velocità fumi attesa Pr37 Fume extractor fan speed during waitingPr38 Blocco riaccensione Pr38 Re-lighting delayPr39 Tempo di spegnimento aspiratore fumi Pr39 Fume extractor fan off timePr40 Tempo di precaria in accensione Pr40 Pre-charge time during lightingPr41 Tempo di attesa dopo precarica Pr41 Wait time after pre-charging Pr42 Velocità aspiratore fumi in fase di precarica Pr42 Extractor fan speed during pre-chargingPr43 Isteresi temperatura ON/OFF in modalità automatica

Pr43 ON/OFF hysteresis temperature interval in automatic mode

Pr44 Ritardo allo spegnimento in modalità automatica Pr44 Shutdown delay in automatic modePr45 Ritardo cambio potenza Pr45 Power level switching delayPr46 Abilitazione comando del remoto Pr46 Remote control enablingPr47 Abilitazione blocco tastiera Pr47 Key lock enablingPr48 Riaccensione automatica dopo black-out Pr48 Automatic re-lighting after power failure

Page 29: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

DESCRIZIONE DETTAGLIATA DEL DETAILED DESCRIPTION OF CONNECTION

COGNOME/NOME TECNICO

FIRMA del TECNICO

Il sottoscritto conferma che il tecnico Palladio gli ha fornito tutte le delucidazioni tecniche necessarie al corretto utilizzo e alla

giusta manutenzione della stufa; pertanto attesta di non aver alcuna riserva da dichiarare.

FIRMA del CLIENTE

IMPORTANTE: Presentare la scheda ad ogni successivo intervento da parte del tecnico Palladio.

SUCCESSIVI INTERVENTI

DATA INTERVENTO DESCRIZIONE DETTAGLIATA DELL'INTERVENTO

DESCRIZIONE DETTAGLIATA DEL COLLEGAMENTO DEL TUBO DI SCARICO FUMI ALLA CANNA FUMARIA (OBBLIGATORIA PER LEGGE).

Page 30: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

COLLEGAMENTO DEL TUBO DI SCARICO FUMI ALLA CANNA FUMARIA (OBBLIGATORIA PER LEGGE).

BETWEEN STOVE EXHAUST AND FLUE (LEGAL REQUIREMENT).

COGNOME/NOME TECNICO NAME/SURNAME OF COMMISSIONING ENGINEER

FIRMA del TECNICO SIGNATURE OF COMMISSIONING ENGINEERIl sottoscritto conferma che il tecnico Palladio gli ha fornito tutte le delucidazioni tecniche necessarie al corretto utilizzo e alla giusta manutenzione della stufa; pertanto attesta di non aver alcuna riserva da dichiarare.

I, the undersigned, hereby confirm that Palladio’s commissioning engineer has provided me with all the technical explanations necessary for the correct operation and maintenance of the stove and that I unreservedly accept the product.

FIRMA del CLIENTE SIGNATURE OF CUSTOMERIMPORTANTE: Presentare la scheda ad ogni successivo intervento da parte del tecnico Palladio.

IMPORTANT: This form must be presented to the Palladio service engineer whenever the stove is serviced.

SUCCESSIVI INTERVENTI SUBSEQUENT WORKDATA INTERVENTO DATE OF WORK DESCRIZIONE DETTAGLIATA DELL'INTERVENTO

DETAILED DESCRIPTION OF WORK PERFORME

CERTIFICATE OF WARRANTYPurpose of this certificate

This certificate, presented along with an invoice and/or tax receipt or bill of sale, is the only document valid for the purpose of recognising the warranty. It must be presented to the manufacturer's service engineer whenever work is performed on the stove.All copies of this certificate of warranty must be compiled in full. The first section must be completed by the retailer. The second section must

be completed by the Technical Assistance Centre’s service engineer as part of mandatory commissioning.Terms of the warranty

1- The manufacturer guarantees this stove to be free from defects for a period of twenty-four (24) months starting from the date of purchase, when installed anywhere in Italy.2- This certificate of warranty must be kept and presented, along with proof of purchase, to the service engineer of the Palladio Technical Assistance Centre whenever work is performed on the stove. This certificate of warranty must be stamped and signed by the retailer. The section reserved for the Technical Assistance Centre must be compiled before this certificate is returned by post to Edilvalli Arredi S.r.l..3- The manufacturer hereby undertakes to repair, free of charge, any parts proven to be defective at origin. This warranty only applies to the original purchaser.4- The present warranty only applies to faults deriving from defects in manufacturing. It expressly excludes faults caused by insufficient or incorrect maintenance, unsuitable or incorrect operation, incorrect installation, improper use, the purchaser’s negligence and/or lack of care, use of unsuitable fuel types, and any other cause not directly dependent on Edilvalli Arredi. It also expressly excludes damage caused to parts during transport of which the manufacturer is not notified within four (4) days from the delivery of the product, and damage caused by natural events and acts of God (earthquakes, floods, lightning strikes, etc.).5- This warranty expressly excludes the responsibility of Edilvalli Arredi for damage or injury caused directly or indirectly to persons, animals or property, incurred through loss of use, and for any other economic losses resulting from use of the stove or from the enforced suspension of that use.6- Any tampering, modification or repair to the stove by personnel not authorised by Palladio automatically invalidates the warranty. Repairs performed during the warranty period do not extend or renew the warranty’s validity period in any way. Failure to have the stove serviced annually by an authorised Technical Assistance Centre also invalidates the warranty.7- The present warranty does not affect the purchaser’s legal rights; it is intended to complement consumer protection legislation and not replace it.8- All installation and commissioning costs, as well any call-out and transfer fees for installation and commissioning engineers are entirely at the purchaser’s expense. All call-out fees and costs incurred for the recalibration and fine tuning of the product not due to its control devices are also at the purchaser’s own expense. Edilvalli Arredi declines all responsibility for fumes leaking or escaping from the stove if it is not installed in conformity to applicable directives and legislation.9- PALLADIO undertakes to replace all parts proven to be defective for a period of two (2) years. This warranty excludes all additional costs incurred for call-out fees, consumables, labour, transport, telehandlers, scaffolding, and any other form of lifting equipment.10- Pin-point holes, variations in colour and shade, slight variation of shape and hairline cracks in the majolica covering do not constitute defects but are natural characteristics of the material and the firing process.11- Purposes for which personal data may be used under "Law 675/96". The manufacturer hereby notifies the purchaser that the personal data he provides may be used in the ways permitted by Article 1 of Italian law 675/96. Personal data may be used, by way of example, for purposes of purchaser registration prior to and subsequent to the contract of sale, the manufacturer’s operational and internal management requirements, operational and strategic marketing, statistical surveys, technical assistance and warranty management, and commercial promotion and direct sale, either directly or through associated companies responsible for the operation and servicing of the product under the terms of the warranty.In compliance to Article 23 of Italian data privacy legislation (Legislative Decree 196/3), the purchaser hereby expresses his free and informed consent to the use of his personal data for the purposes listed in the clause entitled “Purposes for which personal data may be used” in this notice.

DETAILS OF PURCHASERSurname ________________________________________ Name _________________________________________________Address ______________________________________ Post code _____________ Town/City ___________________________________ County ___________ Phone ___________________________ E-mail _____________________________________________Model of stove ______________________ Date of purchase ___________________ Date of commissioning ______________________Signature (legible) of authorised commissioning engineer ______________________________________ Date of first annual cleaning by TAC ________________ Date of second annual cleaning by TAC ______________This section must be compiled by the TAC on commissioning of the stove.

□ FRAME AND COVERING IN GOOD CONDITION □ FEED SCREW DRIVE FUNCTIONING □ FUME EXTRACTOR FAN FUNCTIONING □ HEAT EXCHANGER FAN FUNCTIONING □ STOVE FUME OUTLET CORRECTLY CONNECTED TO FLUE

□ GLOW PLUG IGNITER FUNCTIONING □ AUTOMATIC FUNCTIONING □ ROOM TEMPERATURE SENSOR FUNCTIONING □ PURCHASER INFORMED ABOUT OPERATION AND CLEANING

THE FOLLOWING OPERATIONS ARE EXPRESSLY EXCLUDED FROM THE TERMS OF THE WARRANTY:- CLEANING OF THE HEARTH/ASH BOX/STOVE; SETTING OF COMBUSTION/TEMPERATURE/PROGRAMMING PARAMETERS - All additional expenses (at applicable local rates) for work performed outside the warranty are at the purchaser’s own expense. Signature of purchaser Stamp and signature of retailer______________________________ ___________________________________

(COPY TO BE KEPT BY PURCHASER)

Page 31: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

CERTIFICATE OF WARRANTYPurpose of this certificate

This certificate, presented along with an invoice and/or tax receipt or bill of sale, is the only document valid for the purpose of recognising the warranty. It must be presented to the manufacturer's service engineer whenever work is performed on the stove.All copies of this certificate of warranty must be compiled in full. The first section must be completed by the retailer. The second section must

be completed by the Technical Assistance Centre’s service engineer as part of mandatory commissioning.Terms of the warranty

1- The manufacturer guarantees this stove to be free from defects for a period of twenty-four (24) months starting from the date of purchase, when installed anywhere in Italy.2- This certificate of warranty must be kept and presented, along with proof of purchase, to the service engineer of the Palladio Technical Assistance Centre whenever work is performed on the stove. This certificate of warranty must be stamped and signed by the retailer. The section reserved for the Technical Assistance Centre must be compiled before this certificate is returned by post to Edilvalli Arredi S.r.l..3- The manufacturer hereby undertakes to repair, free of charge, any parts proven to be defective at origin. This warranty only applies to the original purchaser.4- The present warranty only applies to faults deriving from defects in manufacturing. It expressly excludes faults caused by insufficient or incorrect maintenance, unsuitable or incorrect operation, incorrect installation, improper use, the purchaser’s negligence and/or lack of care, use of unsuitable fuel types, and any other cause not directly dependent on Edilvalli Arredi. It also expressly excludes damage caused to parts during transport of which the manufacturer is not notified within four (4) days from the delivery of the product, and damage caused by natural events and acts of God (earthquakes, floods, lightning strikes, etc.).5- This warranty expressly excludes the responsibility of Edilvalli Arredi for damage or injury caused directly or indirectly to persons, animals or property, incurred through loss of use, and for any other economic losses resulting from use of the stove or from the enforced suspension of that use.6- Any tampering, modification or repair to the stove by personnel not authorised by Palladio automatically invalidates the warranty. Repairs performed during the warranty period do not extend or renew the warranty’s validity period in any way. Failure to have the stove serviced annually by an authorised Technical Assistance Centre also invalidates the warranty.7- The present warranty does not affect the purchaser’s legal rights; it is intended to complement consumer protection legislation and not replace it.8- All installation and commissioning costs, as well any call-out and transfer fees for installation and commissioning engineers are entirely at the purchaser’s expense. All call-out fees and costs incurred for the recalibration and fine tuning of the product not due to its control devices are also at the purchaser’s own expense. Edilvalli Arredi declines all responsibility for fumes leaking or escaping from the stove if it is not installed in conformity to applicable directives and legislation.9- PALLADIO undertakes to replace all parts proven to be defective for a period of two (2) years. This warranty excludes all additional costs incurred for call-out fees, consumables, labour, transport, telehandlers, scaffolding, and any other form of lifting equipment.10- Pin-point holes, variations in colour and shade, slight variation of shape and hairline cracks in the majolica covering do not constitute defects but are natural characteristics of the material and the firing process.11- Purposes for which personal data may be used under "Law 675/96". The manufacturer hereby notifies the purchaser that the personal data he provides may be used in the ways permitted by Article 1 of Italian law 675/96. Personal data may be used, by way of example, for purposes of purchaser registration prior to and subsequent to the contract of sale, the manufacturer’s operational and internal management requirements, operational and strategic marketing, statistical surveys, technical assistance and warranty management, and commercial promotion and direct sale, either directly or through associated companies responsible for the operation and servicing of the product under the terms of the warranty.In compliance to Article 23 of Italian data privacy legislation (Legislative Decree 196/3), the purchaser hereby expresses his free and informed consent to the use of his personal data for the purposes listed in the clause entitled “Purposes for which personal data may be used” in this notice.

DETAILS OF PURCHASERSurname ________________________________________ Name _________________________________________________Address ______________________________________ Post code _____________ Town/City ___________________________________ County ___________ Phone ___________________________ E-mail _____________________________________________Model of stove ______________________ Date of purchase ___________________ Date of commissioning ______________________Signature (legible) of authorised commissioning engineer ______________________________________ Date of first annual cleaning by TAC ________________ Date of second annual cleaning by TAC ______________This section must be compiled by the TAC on commissioning of the stove.

□ FRAME AND COVERING IN GOOD CONDITION □ FEED SCREW DRIVE FUNCTIONING □ FUME EXTRACTOR FAN FUNCTIONING □ HEAT EXCHANGER FAN FUNCTIONING □ STOVE FUME OUTLET CORRECTLY CONNECTED TO FLUE

□ GLOW PLUG IGNITER FUNCTIONING □ AUTOMATIC FUNCTIONING □ ROOM TEMPERATURE SENSOR FUNCTIONING □ PURCHASER INFORMED ABOUT OPERATION AND CLEANING

THE FOLLOWING OPERATIONS ARE EXPRESSLY EXCLUDED FROM THE TERMS OF THE WARRANTY:- CLEANING OF THE HEARTH/ASH BOX/STOVE; SETTING OF COMBUSTION/TEMPERATURE/PROGRAMMING PARAMETERS - All additional expenses (at applicable local rates) for work performed outside the warranty are at the purchaser’s own expense. Signature of purchaser Stamp and signature of retailer______________________________ ___________________________________

(COPY TO BE KEPT BY RETAILER)

Page 32: PALLADIO - pelletkachels.nu · PALLADIO Installation, operation and maintenance manual Dear Customer, We thank you for having chosen a Palladio stove from Edilvalli Arredi S.r.l..

PALLADIO

CERTIFICATE OF WARRANTYPurpose of this certificate

This certificate, presented along with an invoice and/or tax receipt or bill of sale, is the only document valid for the purpose of recognising the warranty. It must be presented to the manufacturer's service engineer whenever work is performed on the stove.All copies of this certificate of warranty must be compiled in full. The first section must be completed by the retailer. The second section must

be completed by the Technical Assistance Centre’s service engineer as part of mandatory commissioning.Terms of the warranty

1- The manufacturer guarantees this stove to be free from defects for a period of twenty-four (24) months starting from the date of purchase, when installed anywhere in Italy.2- This certificate of warranty must be kept and presented, along with proof of purchase, to the service engineer of the Palladio Technical Assistance Centre whenever work is performed on the stove. This certificate of warranty must be stamped and signed by the retailer. The section reserved for the Technical Assistance Centre must be compiled before this certificate is returned by post to Edilvalli Arredi S.r.l..3- The manufacturer hereby undertakes to repair, free of charge, any parts proven to be defective at origin. This warranty only applies to the original purchaser.4- The present warranty only applies to faults deriving from defects in manufacturing. It expressly excludes faults caused by insufficient or incorrect maintenance, unsuitable or incorrect operation, incorrect installation, improper use, the purchaser’s negligence and/or lack of care, use of unsuitable fuel types, and any other cause not directly dependent on Edilvalli Arredi. It also expressly excludes damage caused to parts during transport of which the manufacturer is not notified within four (4) days from the delivery of the product, and damage caused by natural events and acts of God (earthquakes, floods, lightning strikes, etc.).5- This warranty expressly excludes the responsibility of Edilvalli Arredi for damage or injury caused directly or indirectly to persons, animals or property, incurred through loss of use, and for any other economic losses resulting from use of the stove or from the enforced suspension of that use.6- Any tampering, modification or repair to the stove by personnel not authorised by Palladio automatically invalidates the warranty. Repairs performed during the warranty period do not extend or renew the warranty’s validity period in any way. Failure to have the stove serviced annually by an authorised Technical Assistance Centre also invalidates the warranty.7- The present warranty does not affect the purchaser’s legal rights; it is intended to complement consumer protection legislation and not replace it.8- All installation and commissioning costs, as well any call-out and transfer fees for installation and commissioning engineers are entirely at the purchaser’s expense. All call-out fees and costs incurred for the recalibration and fine tuning of the product not due to its control devices are also at the purchaser’s own expense. Edilvalli Arredi declines all responsibility for fumes leaking or escaping from the stove if it is not installed in conformity to applicable directives and legislation.9- PALLADIO undertakes to replace all parts proven to be defective for a period of two (2) years. This warranty excludes all additional costs incurred for call-out fees, consumables, labour, transport, telehandlers, scaffolding, and any other form of lifting equipment.10- Pin-point holes, variations in colour and shade, slight variation of shape and hairline cracks in the majolica covering do not constitute defects but are natural characteristics of the material and the firing process.11- Purposes for which personal data may be used under "Law 675/96". The manufacturer hereby notifies the purchaser that the personal data he provides may be used in the ways permitted by Article 1 of Italian law 675/96. Personal data may be used, by way of example, for purposes of purchaser registration prior to and subsequent to the contract of sale, the manufacturer’s operational and internal management requirements, operational and strategic marketing, statistical surveys, technical assistance and warranty management, and commercial promotion and direct sale, either directly or through associated companies responsible for the operation and servicing of the product under the terms of the warranty.In compliance to Article 23 of Italian data privacy legislation (Legislative Decree 196/3), the purchaser hereby expresses his free and informed consent to the use of his personal data for the purposes listed in the clause entitled “Purposes for which personal data may be used” in this notice.

DETAILS OF PURCHASERSurname ________________________________________ Name _________________________________________________Address ______________________________________ Post code _____________ Town/City ___________________________________ County ___________ Phone ___________________________ E-mail _____________________________________________Model of stove ______________________ Date of purchase ___________________ Date of commissioning ______________________Signature (legible) of authorised commissioning engineer ______________________________________ Date of first annual cleaning by TAC ________________ Date of second annual cleaning by TAC ______________This section must be compiled by the TAC on commissioning of the stove.

□ FRAME AND COVERING IN GOOD CONDITION □ FEED SCREW DRIVE FUNCTIONING □ FUME EXTRACTOR FAN FUNCTIONING □ HEAT EXCHANGER FAN FUNCTIONING □ STOVE FUME OUTLET CORRECTLY CONNECTED TO FLUE

□ GLOW PLUG IGNITER FUNCTIONING □ AUTOMATIC FUNCTIONING □ ROOM TEMPERATURE SENSOR FUNCTIONING □ PURCHASER INFORMED ABOUT OPERATION AND CLEANING

THE FOLLOWING OPERATIONS ARE EXPRESSLY EXCLUDED FROM THE TERMS OF THE WARRANTY:- CLEANING OF THE HEARTH/ASH BOX/STOVE; SETTING OF COMBUSTION/TEMPERATURE/PROGRAMMING PARAMETERS - All additional expenses (at applicable local rates) for work performed outside the warranty are at the purchaser’s own expense. Signature of purchaser Stamp and signature of retailer______________________________ ___________________________________

(COPY TO BE RETURNED TO EDILVALLI ARREDI S.R.L. IN A SEALED ENVELOPE)


Recommended