RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

PANNELLO COMANDOPANNELLO COMANDO

– DISPLAY LCD 70 mm X 50 mmDISPLAY LCD 70 mm X 50 mm

– TASTI TEMPERATURA SANITARIOTASTI TEMPERATURA SANITARIO

– TASTI TEMPERATURA RISCALDAMENTOTASTI TEMPERATURA RISCALDAMENTO

– SELETTORE STAGIONALE + ON/OFFSELETTORE STAGIONALE + ON/OFF

– TASTO ATTIVAZIONE PRERISCALDOTASTO ATTIVAZIONE PRERISCALDO

– TASTO MENU’ INFOTASTO MENU’ INFO

– TASTO RESETTASTO RESET

M262 M M262 M

PANNELLO COMANDI PANNELLO COMANDI “TOP”“TOP”

Page 3: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

INDICAZIONI DISPLAY TOPINDICAZIONI DISPLAY TOP

REMOTO COLLEGATO;REMOTO COLLEGATO;

SE LAMPEGGIANTE SE LAMPEGGIANTE RICHIESTA IN ATTORICHIESTA IN ATTO POMPA ALIMENTATAPOMPA ALIMENTATA

PRESENZA FIAMMA E PRESENZA FIAMMA E LIVELLO DI LIVELLO DI MODULAZIONEMODULAZIONE

TEMP. ESTERNA TEMP. ESTERNA (SE COLLEGATA S.E.)(SE COLLEGATA S.E.)

ANTIGELOANTIGELO

PRESSIONE IN PRESSIONE IN CALDAIACALDAIA

SCADENZA SCADENZA MANUTENZIONEMANUTENZIONE

PRERISCALDO ATTIVO;PRERISCALDO ATTIVO;

SE LAMPEGGIANTE SE LAMPEGGIANTE PRERISCALDO IN ATTOPRERISCALDO IN ATTO

RICHIESTA RICHIESTA RISCALDAMENTORISCALDAMENTO

INGRESSO MENU’ INFOINGRESSO MENU’ INFO

LIVELLO INTEGRAZIONE LIVELLO INTEGRAZIONE SOLARESOLARE

ATTESA RIACCENSIONE ATTESA RIACCENSIONE BRUCIATOREBRUCIATORE

SPAZZACAMINO SPAZZACAMINO ATTIVOATTIVO

Page 4: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

SCHEMA ELETTRICO INOVIA COND MAXSCHEMA ELETTRICO INOVIA COND MAX

SCHEDA SIT SCHEDA SIT

14064.1208.14064.1208.88

Page 5: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

COLLEGAMENTI ELETTRICICOLLEGAMENTI ELETTRICI

COLLEGAMENTI ELETTRICI ESTERNI

ALLOGGIAMENTO ALLOGGIAMENTO SCHEDA COMANDO E SCHEDA COMANDO E CONNESSIONI CONNESSIONI ELETTRICHE ESTERNEELETTRICHE ESTERNE

Sonda bollitore

Page 6: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

COLLEGAMENTI ELETTRICICOLLEGAMENTI ELETTRICICOLLEGAMENTI ELETTRICI ESTERNI AUSILIARI M262.2025

SB/T

Page 7: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

• SCHEDA INTEGRATA SIT SCHEDA INTEGRATA SIT 14064.1208.814064.1208.8

• FUNZIONI NORMALIFUNZIONI NORMALI– MODULAZIONE IN SANITARIOMODULAZIONE IN SANITARIO– MODULAZIONE RISCALDAMENTOMODULAZIONE RISCALDAMENTO– GESTIONE GUASTO SONDE GESTIONE GUASTO SONDE – FUNZIONE ANTIGELO E 24 hFUNZIONE ANTIGELO E 24 h– GESTIONE SONDA ESTERNAGESTIONE SONDA ESTERNA

SCHEDA COMANDOSCHEDA COMANDO

• FUNZIONI PARTICOLARIFUNZIONI PARTICOLARI– GESTIONE VELOCITA’ POMPA; GESTIONE VELOCITA’ POMPA; – GESTIONE VALVOLA DI ZONA GESTIONE VALVOLA DI ZONA – PRERISCALDO CON PROGRAMMAZIONE ORARIAPRERISCALDO CON PROGRAMMAZIONE ORARIA– VISUALIZZAZIONE INFO SOLARE VISUALIZZAZIONE INFO SOLARE – SCADENZA MANUTENZIONESCADENZA MANUTENZIONE

Page 8: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServiceServiceNTC RISCALDAMENTO NTC RISCALDAMENTO

NTC RISCALDAMENTO NTC RISCALDAMENTO SONDA DI TEMPERATURA A 2POLI POSTA SONDA DI TEMPERATURA A 2POLI POSTA

SULL’USCITA DELLO SCAMBIATORE PRIMARIOSULL’USCITA DELLO SCAMBIATORE PRIMARIO – COMUNICA ALLA SCHEDA LA TEMPERATURA COMUNICA ALLA SCHEDA LA TEMPERATURA

DI USCITA DELL’ACQUA DALLO DI USCITA DELL’ACQUA DALLO SCAMBIATORE PRIMARIO TRADUCENDOLA IN SCAMBIATORE PRIMARIO TRADUCENDOLA IN UN SEGNALE ELETTRICO PER:UN SEGNALE ELETTRICO PER:

• GESTIONE MODULAZIONE GESTIONE MODULAZIONE RISCALDAMENTORISCALDAMENTO

• CONTROLLO CIRCOLAZIONE CIRCUITO CONTROLLO CIRCOLAZIONE CIRCUITO PRIMARIO (VERIFICA DELLA VELOCITA’ DI PRIMARIO (VERIFICA DELLA VELOCITA’ DI INCREMENTO DELLA TEMPERATURA)INCREMENTO DELLA TEMPERATURA)

Page 9: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

• COMPITOCOMPITO– PERMETTE DI MANTENERE COSTANTE LA TEMPERATURA IN MANDATA; PERMETTE DI MANTENERE COSTANTE LA TEMPERATURA IN MANDATA;

LA VARIAZIONE DI POTENZA AL BRUCIATORE E’ DATA DAL VARIARE LA VARIAZIONE DI POTENZA AL BRUCIATORE E’ DATA DAL VARIARE DEL NUMERO DI GIRI DEL VENTILATOREDEL NUMERO DI GIRI DEL VENTILATORE

• CARATTERISTICHECARATTERISTICHE– CONTROLLO DELLA TEMPERATURA ATTRAVERSO NTC PRIMARIO DI CONTROLLO DELLA TEMPERATURA ATTRAVERSO NTC PRIMARIO DI

MANDATAMANDATA– RAMPA DI SALITA FIAMMA: RAMPA DI SALITA FIAMMA:

– NEI PRIMI 2 MINUTI DOPO LA RICHIESTA LA FIAMMA RIMANE NEI PRIMI 2 MINUTI DOPO LA RICHIESTA LA FIAMMA RIMANE SEMPRE AL MINIMOSEMPRE AL MINIMO

– IN QUESTO PERIODO VIENE VERIFICATO L’AUMENTO DELLA IN QUESTO PERIODO VIENE VERIFICATO L’AUMENTO DELLA TEMPERATURA:SE L’AUMENTO E’ MINORE DI 5°C/MINUTO LA TEMPERATURA:SE L’AUMENTO E’ MINORE DI 5°C/MINUTO LA FIAMMA VIENE IMPOSTATA PER UN INCREMENTO DI 1° C OGNI 10 FIAMMA VIENE IMPOSTATA PER UN INCREMENTO DI 1° C OGNI 10 sec. (NTC DI MANDATA)sec. (NTC DI MANDATA)

– LA RAMPA DI SALITA SI INTERROMPE NON APPENA RAGGIUNTO IL LA RAMPA DI SALITA SI INTERROMPE NON APPENA RAGGIUNTO IL VALORE IMPOSTATO/CALCOLATOVALORE IMPOSTATO/CALCOLATO

– IL BRUCIATORE SI SPEGNE AL SUPERAMENTO IL BRUCIATORE SI SPEGNE AL SUPERAMENTO DEL SET IMPOSTATO; DEL SET IMPOSTATO;

– NEL TEMPO DI SPEGNIMENTO (NEL TEMPO DI SPEGNIMENTO (P10P10) IL DISPLAY INDICA) IL DISPLAY INDICA

MODULAZIONE RISCALDAMENTOMODULAZIONE RISCALDAMENTO

DISPLAY DISPLAY

MEDIUMMEDIUM

DISPLAY TOPDISPLAY TOP

Page 10: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

MODULAZIONE RISCALDAMENTO MODULAZIONE RISCALDAMENTO CON SONDA ESTERNACON SONDA ESTERNA

• COMPITOCOMPITO– FAR LAVORARE L’IMPIANTO ALLA TEMPERATURA PIU’ INDICATA IN BASE ALLA FAR LAVORARE L’IMPIANTO ALLA TEMPERATURA PIU’ INDICATA IN BASE ALLA

TEMPERATURA ESTERNA, MIGLIORANDO IL RENDIMNETO DI CALDAIA ED IMPIANTOTEMPERATURA ESTERNA, MIGLIORANDO IL RENDIMNETO DI CALDAIA ED IMPIANTO

• CARATTERISTICHECARATTERISTICHE– CONTROLLO DELLA TEMPERATURA ESTERNA TRAMITE SONDA ESTERNACONTROLLO DELLA TEMPERATURA ESTERNA TRAMITE SONDA ESTERNA

– OBBLIGATORIO IMPOSTARE IL COEFFICIENTE K OBBLIGATORIO IMPOSTARE IL COEFFICIENTE K (P15)(P15) PER RELAZIONARE LA PER RELAZIONARE LA TEMPERATURA DI MANDATA CON LA TEMPERATURA ESTERNA IN BASE ALLA ZONA TEMPERATURA DI MANDATA CON LA TEMPERATURA ESTERNA IN BASE ALLA ZONA CLIMATICA ED AL TIPO DI IMPIANTOCLIMATICA ED AL TIPO DI IMPIANTO

• PARAMETRI IMPOSTABILIPARAMETRI IMPOSTABILI

– P15P15 E’ IMPOSTABILE DA 01 A 60: E’ IMPOSTABILE DA 01 A 60:– (01 >>> K =0,1)(01 >>> K =0,1)– (60 >>> K =6,0)(60 >>> K =6,0)

– P7P7 MANDATA MASSIMA (45-85°) MANDATA MASSIMA (45-85°)

– P27 P27 MANDATA MINIMA (25-45°)MANDATA MINIMA (25-45°)– TRAMITE I TASTI SELEZIONE TEMP. TRAMITE I TASTI SELEZIONE TEMP.

MANDATA E’ POSSIBILE ALZARE O MANDATA E’ POSSIBILE ALZARE O ABBASSARE LA CURVA DI 15°CABBASSARE LA CURVA DI 15°C

P7 (45-85°)

P27 (25-45°)

Nel grafico in figura si vede l’effetto che ha l’impostazione dei parametri P15=2 P7=70 P27=35 sulla temperatura di mandata evidenziata in rosso

Page 11: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

MODULAZIONE SANITARIOMODULAZIONE SANITARIO

• COMPITOCOMPITO– MANTENERE COSTANTE LA TEMPERATURA DI MANTENERE COSTANTE LA TEMPERATURA DI

ACQUA CALDA SANITARIA ACQUA CALDA SANITARIA – IL CONFRONTO TRA LA TEMPERATURA LETTA DA IL CONFRONTO TRA LA TEMPERATURA LETTA DA

NTC E SET IMPOSTATO PORTA ALLA VARIAZIONE NTC E SET IMPOSTATO PORTA ALLA VARIAZIONE DEL NUMERO DI GIRI DEL VENTILATOREDEL NUMERO DI GIRI DEL VENTILATORE

– NEL CASO NEL CASO NTC RNTC R > 90° IL BRUCIATORE VIENE > 90° IL BRUCIATORE VIENE

SPENTO ED IL DISPLAY INDICA SPENTO ED IL DISPLAY INDICA L01L01

– UTILIZZO DELLA SONDA RITORNO PRIMARIO PER IL UTILIZZO DELLA SONDA RITORNO PRIMARIO PER IL CONTROLLO DELLA TEMPERATURA DURANTE LA CONTROLLO DELLA TEMPERATURA DURANTE LA FUNZIONE SANITARIO A 60°C (MAX 65°C) PER FUNZIONE SANITARIO A 60°C (MAX 65°C) PER LIMITARE LE TEMPERATURE ALL’INTERNO DEL LIMITARE LE TEMPERATURE ALL’INTERNO DEL BOLLITORE E LIMITARE LA FORMAZIONE DI BOLLITORE E LIMITARE LA FORMAZIONE DI CALCARECALCARE

Page 12: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

FUNZIONE ANTILEGIONELLAFUNZIONE ANTILEGIONELLA• COMPITOCOMPITO

– ELIMINA EVENTUALI MICRORGANISMI PRESENTI NELL’ACCUMULO ELIMINA EVENTUALI MICRORGANISMI PRESENTI NELL’ACCUMULO • DATIDATI

– PORTA LA TEMPERATURA DELL’ACQUA CONTENUTA NEL BOLLITORE OLTRE I 65°C PER UN PERIODO MASSIMO DI 15 MINPORTA LA TEMPERATURA DELL’ACQUA CONTENUTA NEL BOLLITORE OLTRE I 65°C PER UN PERIODO MASSIMO DI 15 MIN

– CONTROLLO TEMPERATURA ATTRAVERSO LA SONDA CONTROLLO TEMPERATURA ATTRAVERSO LA SONDA NTC R NTC R

– PREMERE 10 SEC I TASTIPREMERE 10 SEC I TASTI– 20-23-2420-23-24– PREMERE I TASTI 23-24PREMERE I TASTI 23-24

SCEGLIERE LA FREQUENZA DI IMPIEGOSCEGLIERE LA FREQUENZA DI IMPIEGO

Page 13: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

SISTEMA ANTIGELOSISTEMA ANTIGELO

• COMPITOCOMPITO– PROTEGGE LA CALDAIA IN CASO DI BASSE TEMPERATURE PROTEGGE LA CALDAIA IN CASO DI BASSE TEMPERATURE

• DATIDATI– ON 6 °C --- OFF 15° C ON 6 °C --- OFF 15° C

– CONTROLLO TEMPERATURA ATTRAVERSO LA SONDA CONTROLLO TEMPERATURA ATTRAVERSO LA SONDA NTC RNTC R– IL BRUCIATORE VIENE ACCESO ALLA MINIMA POTENZA, IL BRUCIATORE VIENE ACCESO ALLA MINIMA POTENZA,

VALVOLA TRE VIE IN SANIATRIOVALVOLA TRE VIE IN SANIATRIO

FUNZIONE FUNZIONE ““VENTIQUATTROREVENTIQUATTRORE””

• COMPITOCOMPITO– EVITA CHE IL CIRCOLATORE SI BLOCCHI NEL CASO LA CALDAIA RESTI EVITA CHE IL CIRCOLATORE SI BLOCCHI NEL CASO LA CALDAIA RESTI

INATTIVA PER LUNGHI PERIODIINATTIVA PER LUNGHI PERIODI• DATIDATI

– ON QUANDO LA CALDAIA RESTA INATTIVA PER PIU’ DI 24 OREON QUANDO LA CALDAIA RESTA INATTIVA PER PIU’ DI 24 ORE– I CIRCOLATORI VENGONO ALIMENTATI PER 30 SECONDII CIRCOLATORI VENGONO ALIMENTATI PER 30 SECONDI

Page 14: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

GESTIONE GUASTO SONDE GESTIONE GUASTO SONDE

• GUASTO SONDE RISCALDAMENTOGUASTO SONDE RISCALDAMENTO

– ANOMALIA TRAMITE DISPLAY: ANOMALIA TRAMITE DISPLAY: E06E06 + + (sonda (sonda mandata)mandata)

– ANOMALIA TRAMITE DISPLAY: ANOMALIA TRAMITE DISPLAY: E12E12 + + (sonda (sonda ritorno)ritorno)

– UN GUASTO ALLE SONDE RISCALDAMENTO IMPEDISCE UN GUASTO ALLE SONDE RISCALDAMENTO IMPEDISCE QUALUNQUE ACCENSIONE DEL BRUCIATORE; QUALUNQUE ACCENSIONE DEL BRUCIATORE;

• GUASTO SONDA SANITARIOGUASTO SONDA SANITARIO

– ANOMALIA TRAMITE DISPLAY: ANOMALIA TRAMITE DISPLAY: E07E07 + + – UN GUASTO ALLA SONDA SANITARIA (CORTO CIRCUITO UN GUASTO ALLA SONDA SANITARIA (CORTO CIRCUITO

O INTERROTTA) NON IMPEDISCE NESSUNA FUNZIONE;O INTERROTTA) NON IMPEDISCE NESSUNA FUNZIONE;• GUASTO SONDA ESTERNAGUASTO SONDA ESTERNA

– ANOMALIA TRAMITE DISPLAY: ANOMALIA TRAMITE DISPLAY: E08E08 + +– UN GUASTO ALLA SONDA ESTERNA NON IMPEDISCE UN GUASTO ALLA SONDA ESTERNA NON IMPEDISCE

NESSUNA FUNZIONE MA E’ ESCLUSA LA FUNZIONE NESSUNA FUNZIONE MA E’ ESCLUSA LA FUNZIONE TEMPERATURA SCORREVOLE;TEMPERATURA SCORREVOLE;

• GUASTO SONDA FUMIGUASTO SONDA FUMI

– ANOMALIA TRAMITE DISPLAY: ANOMALIA TRAMITE DISPLAY: E09E09 + +– UN GUASTO ALLA SONDA FUMI IMPEDISCE QUALUNQUE UN GUASTO ALLA SONDA FUMI IMPEDISCE QUALUNQUE

ACCENSIONE DEL BRUCIATORE;ACCENSIONE DEL BRUCIATORE;

Page 15: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

VERIFICA CIRCOLAZIONE ACQUA VERIFICA CIRCOLAZIONE ACQUA

• COMPITOCOMPITO– VERIFICARE LA SUFFICIENTE PORTATA VERIFICARE LA SUFFICIENTE PORTATA

D’ACQUA NELLO SCAMBIATORE PRIMARIOD’ACQUA NELLO SCAMBIATORE PRIMARIO• CARATTERISTICHECARATTERISTICHE

– QUESTA VERIFCA VIENE ESEGUITA QUESTA VERIFCA VIENE ESEGUITA REGISTRANDO LA VARIAZIONE DI REGISTRANDO LA VARIAZIONE DI TEMPERATRA SUL TEMPERATRA SUL NTC RNTC R

– LIMITE MAX INCREMENTO = 4 °C AL LIMITE MAX INCREMENTO = 4 °C AL SECONDOSECONDO

– SE QUESTO LIMITE VIENE SUPERATO:SE QUESTO LIMITE VIENE SUPERATO:

• INDICAZIONE DISPLAY INDICAZIONE DISPLAY E14E14 + +• POMPA E BRUCIATORE SPENTI PER 1 minPOMPA E BRUCIATORE SPENTI PER 1 min• TENTATIVO DI RIACCENSIONE DOPO 1 TENTATIVO DI RIACCENSIONE DOPO 1

minmin

Page 16: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

GESTIONE CIRCOLATOREGESTIONE CIRCOLATORE• COMPITOCOMPITO

– GESTIRE L’ALIMENTAZIONE ALLA POMPA IN BASE ALLO STATO DELLA CALDAIAGESTIRE L’ALIMENTAZIONE ALLA POMPA IN BASE ALLO STATO DELLA CALDAIA• DATIDATI

– E’ SEMPRE IL PRIMO COMPONENTE CHE VIENE ALIMENTATO A FRONTE DI UNA QUALUNQUE RICHIESTAE’ SEMPRE IL PRIMO COMPONENTE CHE VIENE ALIMENTATO A FRONTE DI UNA QUALUNQUE RICHIESTA– PUO’ ESSERE BLOCCATO DA:PUO’ ESSERE BLOCCATO DA:

• SEGNALE DI PRESSIONE CALDAIA TROPPO BASSA SEGNALE DI PRESSIONE CALDAIA TROPPO BASSA

• SCARSA CIRCOLAZIONE D’ACQUA (INCREMENTO TEMP SU SCARSA CIRCOLAZIONE D’ACQUA (INCREMENTO TEMP SU NTC RNTC R > 4° C/sec) > 4° C/sec)– POST CIRCOLAZIONE DIFFERENZIATA:POST CIRCOLAZIONE DIFFERENZIATA:

• DOPO RICHIESTA SANITARIO: 30 sec (NON MODIFICABILE)DOPO RICHIESTA SANITARIO: 30 sec (NON MODIFICABILE)

• DOPO RICHIESTA RISCALDAMENTO: 1 min (DEFAULT) (MODIFICABILE : DOPO RICHIESTA RISCALDAMENTO: 1 min (DEFAULT) (MODIFICABILE : P11P11= 0 -- 0 sec; = 0 -- 0 sec; P11P11=99 -- 10 min)=99 -- 10 min)– GESTIONE VELOCITA’ (solo INOVIA COND M260T):GESTIONE VELOCITA’ (solo INOVIA COND M260T):

• CON PARAMETRO CON PARAMETRO P03P03=02 GESTIONE AUTOMATICA (DEFAULT):=02 GESTIONE AUTOMATICA (DEFAULT):– RISCALDAMENTO E SANITARIO: VELOCITA’ MASSIMARISCALDAMENTO E SANITARIO: VELOCITA’ MASSIMA– POST CIRCOLAZIONI, ANTIGELO E PRERISCALDO: VELOCITA’ MINIMAPOST CIRCOLAZIONI, ANTIGELO E PRERISCALDO: VELOCITA’ MINIMA

• CON PARAMETRO CON PARAMETRO P03P03=00 SEMPRE MASSIMA VELOCITA’=00 SEMPRE MASSIMA VELOCITA’

• CON PARAMETRO CON PARAMETRO P03P03=01 SEMPRE’ MINIMA VELOCITA’=01 SEMPRE’ MINIMA VELOCITA’

DISPLAY DISPLAY

MEDIUMMEDIUM

Page 17: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

• COMPITOCOMPITO– VERIFICARE LA CORRETTA FUNZIONALITA’ DEL VERIFICARE LA CORRETTA FUNZIONALITA’ DEL

VENTILATOREVENTILATORE• CARATTERISTICHECARATTERISTICHE

– LA SCHEDA INTEGRATA GENERA UN SEGNALE PWM LA SCHEDA INTEGRATA GENERA UN SEGNALE PWM IN BASE ALLA POTENZA TERMICA RICHIESTA; IN BASE ALLA POTENZA TERMICA RICHIESTA; QUESTO SEGNALE CORRISPONDE AL “NUMERO DI QUESTO SEGNALE CORRISPONDE AL “NUMERO DI GIRI RICHIESTO”GIRI RICHIESTO”

– IL VENTILATORE SI “AUTOVERIFICA” E COMUNICA IL VENTILATORE SI “AUTOVERIFICA” E COMUNICA ALLA SCHEDA IL NUMERO DI GIRI EFFETTIVAMENTE ALLA SCHEDA IL NUMERO DI GIRI EFFETTIVAMENTE EFFETTUATO (EFFETTO HALL)EFFETTUATO (EFFETTO HALL)

– SE IL NUMERO DI GIRI EFFETTUATO DIFFERISCE DA SE IL NUMERO DI GIRI EFFETTUATO DIFFERISCE DA QUELLO RICHIESTO:QUELLO RICHIESTO:

• BRUCIATORE OFFBRUCIATORE OFF

• DISPLAY DISPLAY E05E05 + +• VENTILATORE OFFVENTILATORE OFF

– POST VENTILAZIONE: DOPO OGNI ACCENSIONE DEL POST VENTILAZIONE: DOPO OGNI ACCENSIONE DEL BRUCIATORE IL VENTILATORE RESTA ALIMENTATO BRUCIATORE IL VENTILATORE RESTA ALIMENTATO PER 30 secPER 30 sec

CONTROLLO E GESTIONE VENTILATORECONTROLLO E GESTIONE VENTILATORE

ALIM. 220 V ALIM. 220 V CACA

SEGNALE CONTROLLO SEGNALE CONTROLLO NUMERO DI GIRINUMERO DI GIRI

Page 18: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

• COMPITO:COMPITO:– FUNZIONE CHE PERMETTE DI RIPETERE AUTOMATICAMENTE FINO A 3 FUNZIONE CHE PERMETTE DI RIPETERE AUTOMATICAMENTE FINO A 3

TENTATIVI DI RIACCENSIONE DEL BRUCIATORETENTATIVI DI RIACCENSIONE DEL BRUCIATORE• DATI:DATI:

– SE PER UN QUALUNQUE MOTIVO IL BRUCIATORE NON RIESCE AD SE PER UN QUALUNQUE MOTIVO IL BRUCIATORE NON RIESCE AD ACCENDERSI (MANCATA ACCENSIONE) LA SCHEDA RIPETE FINO 3 ACCENDERSI (MANCATA ACCENSIONE) LA SCHEDA RIPETE FINO 3 TENTATIVI RITARDATI DI 30 sec TEMPO NEL QUALE RIMANE ATTIVO IL TENTATIVI RITARDATI DI 30 sec TEMPO NEL QUALE RIMANE ATTIVO IL VENTILATORE (FUNZIONE PULIZIA CAMERA DI COMBUSTIONE); VENTILATORE (FUNZIONE PULIZIA CAMERA DI COMBUSTIONE);

– LA RILEVAZIONE FIAMMA NON E’ SENSIBILE ALL’INVERSIONE FASE-LA RILEVAZIONE FIAMMA NON E’ SENSIBILE ALL’INVERSIONE FASE-NEUTRO; NEUTRO;

– SE SBAGLIA ANCHE IL TERZO TENTATIVO INDICAZIONE DISPLAY: SE SBAGLIA ANCHE IL TERZO TENTATIVO INDICAZIONE DISPLAY: E01E01

TENTATIVI MULTIPLI DI RIACCENSIONETENTATIVI MULTIPLI DI RIACCENSIONE

Page 19: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

POTENZA UTILE RISCALDAMENTOPOTENZA UTILE RISCALDAMENTO

• COMPITOCOMPITO– ADATTARE LA MASSIMA POTENZA DEL BRUCIATORE IN BASE ALLA DIMENSIONE ADATTARE LA MASSIMA POTENZA DEL BRUCIATORE IN BASE ALLA DIMENSIONE

DELL’IMPIANTO TERMICO SENZA VARIARE LA POTENZA MINIMA O LA POTENZA DELL’IMPIANTO TERMICO SENZA VARIARE LA POTENZA MINIMA O LA POTENZA IN SANITARIO (ANCHE PER VERSIONE SV)IN SANITARIO (ANCHE PER VERSIONE SV)

– TRAMITE IL TRAMITE IL P12P12 E’ POSSIBILE SELEZIONARE LA POTENZA MASSIMA PIU’ E’ POSSIBILE SELEZIONARE LA POTENZA MASSIMA PIU’ INDICATA: IL CAMPO DI MODULAZIONE PUO’ VARIARE COME DA TEBELLAINDICATA: IL CAMPO DI MODULAZIONE PUO’ VARIARE COME DA TEBELLA

PotenzaPotenza Pr 12Pr 12 P. Max P. Max (50/30°c)

P. Min P. Min (50/30°C)(50/30°C)

20/25SM20/25SM 74**74** 21,2021,20 6,506,50

0000 6,506,50 6,506,50

30/35SM30/35SM 84**84** 32,1032,10 9,209,20

0000 9,29,2 9,209,20

Page 20: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

REGOLAZIONE DATA E ORAREGOLAZIONE DATA E ORA

SU QUESTA SCHEDA E’ POSSIBILE IMPOSTARE ORA E SU QUESTA SCHEDA E’ POSSIBILE IMPOSTARE ORA E DATA CHE SERVONO SIA PER IMPOSTARE LE FASCE DATA CHE SERVONO SIA PER IMPOSTARE LE FASCE ORARIE DEL PRERISCALDO CHE PER LA FUNZIONE ORARIE DEL PRERISCALDO CHE PER LA FUNZIONE “SCADENA MANUTENZIONE”“SCADENA MANUTENZIONE”

• IMPOSTAZIONE OROLOGIOIMPOSTAZIONE OROLOGIO

– TENERE PREMUTO PER CIRCA 5 sec IL TASTOTENERE PREMUTO PER CIRCA 5 sec IL TASTO L L – CON I TASTI CON I TASTI AA e e BB SI CAMBIA IL VALORE SI CAMBIA IL VALORE

– CON IL TASTO CON IL TASTO LL SI MEMORIZZA LA MODIFICA SI MEMORIZZA LA MODIFICA

– CON I TASTI CON I TASTI GG e e HH SI PASSA DI PARAMETRO SI PASSA DI PARAMETRO

– CON IL TASTO CON IL TASTO LL SI SALVANO LE MODIFICHE SI SALVANO LE MODIFICHE

– TENENDO PREMUTO TENENDO PREMUTO LL PER 5 sec SI ESCE DALLA PER 5 sec SI ESCE DALLA PROGRAMMAZIONEPROGRAMMAZIONE

Page 21: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

FASCIE ORARIE PRERISCALDOFASCIE ORARIE PRERISCALDO• COMPITOCOMPITO

– PROGRAMMARE LA FUNZIONE PRERISCALDO IN BASE PROGRAMMARE LA FUNZIONE PRERISCALDO IN BASE ALLE REALI ESIGENZE DELL’UTENTEALLE REALI ESIGENZE DELL’UTENTE

• IMPOSTAZIONE FASCIE ORARIE PRERISCALDOIMPOSTAZIONE FASCIE ORARIE PRERISCALDO

1.1. TENERE PREMUTO PER 5 sec I TASTI TENERE PREMUTO PER 5 sec I TASTI LL e e HH

2.2. IL DISPLAY INDICA IL DISPLAY INDICA P1ONP1ON (PRIMO ORARIO DI (PRIMO ORARIO DI ATTIVAZIONE)ATTIVAZIONE)

3.3. CON IL TASTO CON IL TASTO DD SI ENTRA IN MODIFICA DI SI ENTRA IN MODIFICA DI P1ONP1ON

4.4. CON I TASTI CON I TASTI AA e e BB SI IMPOSTA L’ORARIO DESIDERATO SI IMPOSTA L’ORARIO DESIDERATO

5.5. CON IL TASTO CON IL TASTO LL SI MEMORIZZA LA MODIFICA SI MEMORIZZA LA MODIFICA

6.6. CON IL TASTO CON IL TASTO HH SI ESCE DALLA MODIFICA SI ESCE DALLA MODIFICA

7.7. CON I TASTI CON I TASTI GG e e HH SI AVANZA DI PARAMETRO SI AVANZA DI PARAMETRO

8.8. IL DISPLAY INDICA IL DISPLAY INDICA P01OFP01OF (TERMINE PRIMA FASCIA (TERMINE PRIMA FASCIA ORARIA)ORARIA)

9.9. RIPETERE LE OPERAZIONI DAL PUNTO 3RIPETERE LE OPERAZIONI DAL PUNTO 3

10.10.LE FASCIE ORARIE NON UTILIZZATE IMPOSTARE A 00:00LE FASCIE ORARIE NON UTILIZZATE IMPOSTARE A 00:00

11.11.CON IL TASTO CON IL TASTO F F ATTIVARE LA FUNZIONE PRERISCALDOATTIVARE LA FUNZIONE PRERISCALDO

SE TUTTO CORRETTO IL DISPLAY VISUALIZZA LE DUE ICONE SE TUTTO CORRETTO IL DISPLAY VISUALIZZA LE DUE ICONE EVIDENZIATE IN FIGURAEVIDENZIATE IN FIGURA

Page 22: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

• COMPITOCOMPITO– IL COMANDI REMOTO, A FRONTE DI UNA RICHIESTA DI CALORE IL COMANDI REMOTO, A FRONTE DI UNA RICHIESTA DI CALORE

DALL’AMBIENTE, PUO’ COMANDARE L’ACCENSIONE DELLA CALDAIA E DALL’AMBIENTE, PUO’ COMANDARE L’ACCENSIONE DELLA CALDAIA E L’APERTURA DI UNA VALVOLA DI ZONA L’APERTURA DI UNA VALVOLA DI ZONA

• CARATTERISTICHECARATTERISTICHE

– FUNZIONE ATTIVABILE TRAMITE FUNZIONE ATTIVABILE TRAMITE P04P04 (default 00, non attiva)(default 00, non attiva)– SCHEDA AUSILIARE A RELE’ CON USCITA A 220 VacSCHEDA AUSILIARE A RELE’ CON USCITA A 220 Vac– 3 CONTATTI: N (neutro) – NO (apertura) – NC (chiusura)3 CONTATTI: N (neutro) – NO (apertura) – NC (chiusura)– IN CASO DI IMPIANTO CON PIU’ VALVOLE IN CASO DI IMPIANTO CON PIU’ VALVOLE

DI ZONA COLLEGARE I LORO FINE CORSA DI ZONA COLLEGARE I LORO FINE CORSA

SULLA LINEA TA (contatti 1 e 3 in morsettiera).SULLA LINEA TA (contatti 1 e 3 in morsettiera).

IN QUESTO CASO LE TEMPERATURE DI IN QUESTO CASO LE TEMPERATURE DI

MANDATA SONO DIVERSIFICABILI:MANDATA SONO DIVERSIFICABILI:

ZONA REMOTO: SET DA REMOTOZONA REMOTO: SET DA REMOTO

ZONE TA: SET DA PANNELLO COMANDIZONE TA: SET DA PANNELLO COMANDI

CALDAIA CALDAIA

GESTIONE VALVOLA DI ZONAGESTIONE VALVOLA DI ZONA

– IN CASO DI RICHIESTE CONTEMPORANEE LA IN CASO DI RICHIESTE CONTEMPORANEE LA TEMPERATURA DI MANDATA E’ IN FUNZIONE DI: TEMPERATURA DI MANDATA E’ IN FUNZIONE DI: P04P04 = 01 SET RISC. = 01 SET RISC. + ALTO+ ALTO

P04P04 = 02 SET RISC. + BASSO = 02 SET RISC. + BASSO

Page 23: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

SCADENZA MANUTENZIONESCADENZA MANUTENZIONE

• COMPITOCOMPITO– RICORDARE ALLL’UTENTE FINALE LA SCADENZA DELLA RICORDARE ALLL’UTENTE FINALE LA SCADENZA DELLA

MANUTENZIONEMANUTENZIONE.

• INDICAZIONE DISPLAYINDICAZIONE DISPLAY– LA SEGNALAZIONE COMPARE 2 MESI PRIMA DELL’EFFETTIVA LA SEGNALAZIONE COMPARE 2 MESI PRIMA DELL’EFFETTIVA

SCADENZASCADENZA– LA SEGNALAZIONE NON IMPEDISCE ALCUNA FUNZIONE LA SEGNALAZIONE NON IMPEDISCE ALCUNA FUNZIONE

DELL’APPARECCHIODELL’APPARECCHIO

– IL RESET DEI MESI SI FA TRAMITE IL IL RESET DEI MESI SI FA TRAMITE IL PM 28PM 28

Page 24: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

DIAGNOSTICADIAGNOSTICA

Page 25: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

DIAGNOSTICADIAGNOSTICA

Page 26: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

DISPLAY DISPLAY –– MENU MENU’’ INFO INFO

• COMPITOCOMPITO– IL MENU’ INFO PERMETTE ESCLUSIVAMENTE LA LETTURA DEI IL MENU’ INFO PERMETTE ESCLUSIVAMENTE LA LETTURA DEI

“DATI DI SERVIZIO” DELLA CALDAIA DURANTE IL “DATI DI SERVIZIO” DELLA CALDAIA DURANTE IL FUNZIONAMENTOFUNZIONAMENTO.

• UTILIZZO MENU’ INFOUTILIZZO MENU’ INFO– PER ENTRARE NEL MENU’ INFOPER ENTRARE NEL MENU’ INFO

• TOPTOP: PREMERE IL PULSANTE : PREMERE IL PULSANTE BB FINO A CHE IL DISPLAY FINO A CHE IL DISPLAY NON INDICA NON INDICA J00J00 + VALORE PARAMETRO + VALORE PARAMETRO

• MEDIUMMEDIUM: PREMERE C + D FINO A CHE IL DISPLAY NON : PREMERE C + D FINO A CHE IL DISPLAY NON INDICA INDICA d0d0 + VALORE PARAMETRO + VALORE PARAMETRO

– PER SCORRERE I PARAMETRI UTILIZZARE I TASTI PER SCORRERE I PARAMETRI UTILIZZARE I TASTI CC o o DD– PER USCIRE DAL MENU’ INFO PREMERE PER USCIRE DAL MENU’ INFO PREMERE

CONTEMPORANEAMENTE I TASTI CONTEMPORANEAMENTE I TASTI AA e e DD

AA

CC

DD

BB

Page 27: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

DISPLAY DISPLAY –– MENU INFO MENU INFO

Page 28: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

MENUMENU’’ HISTORY HISTORY

• COMPITOCOMPITO– LA MODALITA’ HISTORY PERMETTE LA VISUALIZZAZIONE GLI ULTIMI 10 ERRORILA MODALITA’ HISTORY PERMETTE LA VISUALIZZAZIONE GLI ULTIMI 10 ERRORI

• DATIDATI– PER ACCEDERE ALLA MODALITA’ “HISTORY” VEDI IMMAGINI SEGUENTIPER ACCEDERE ALLA MODALITA’ “HISTORY” VEDI IMMAGINI SEGUENTI– NEL DISPLAY COMPARIRA’ IL CODICE DELL’ERRORE ALTERNATO DAL NUMERO NEL DISPLAY COMPARIRA’ IL CODICE DELL’ERRORE ALTERNATO DAL NUMERO

PROGRESSIVO DELL’ERRORE (PROGRESSIVO DELL’ERRORE (H00H00 + + EE - - INDICA L’ULTIMO ERRORE - - INDICA L’ULTIMO ERRORE REGISTRATO) REGISTRATO)

– IL PRIMO ERRORE CHE COMPARIRA’ E’ L’ULTIMO ACCADUTO.IL PRIMO ERRORE CHE COMPARIRA’ E’ L’ULTIMO ACCADUTO.– TRAMITE I TASTI DEL SANITARIO SI POSSONO SCORRERE GLI ULTIMI 10 ERRORI TRAMITE I TASTI DEL SANITARIO SI POSSONO SCORRERE GLI ULTIMI 10 ERRORI

MEMORIZZATI.MEMORIZZATI.

Page 29: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

• COMPITOCOMPITO– SETTARE LA SCHEDA DI RICAMBIO SETTARE LA SCHEDA DI RICAMBIO – ADATTARE LA CALDAIA AL TIPO DI IMPIANTOADATTARE LA CALDAIA AL TIPO DI IMPIANTO

• SCHEDA DI RICAMBIOSCHEDA DI RICAMBIO– APPENA INSTALLATA LA SCHEDA DI RICAMBIO VIENE APPENA INSTALLATA LA SCHEDA DI RICAMBIO VIENE

SEGNALATO SEGNALATO E99E99. . TALE ERRORE SI RESETTA SOLO TALE ERRORE SI RESETTA SOLO IMPOSTANDO IL PARAMETROIMPOSTANDO IL PARAMETRO P01P01

• INGRESSO MENU’ PROGRAMMAZIONE DA PANN. COMANDIINGRESSO MENU’ PROGRAMMAZIONE DA PANN. COMANDI

– TENERE PREMUTO I PULSANTI TENERE PREMUTO I PULSANTI A+B+DA+B+D IN FIGURA (CIRCA 10 IN FIGURA (CIRCA 10

sec): IL DISPLAY INDICHERAsec): IL DISPLAY INDICHERA’’ P01P01 CON IL RELATIVO VALORE CON IL RELATIVO VALORE IMPOSTATOIMPOSTATO

– CON I TASTI CON I TASTI AA e e BB SI SCORRONO I VARI PARAMETRI SI SCORRONO I VARI PARAMETRI

– CON I TASTI CON I TASTI HH e e GG SI MODIFICANO I VALORI IMPOSTATI SI MODIFICANO I VALORI IMPOSTATI

– CON IL TASTO CON IL TASTO DD SI CONFERMA LA MODIFICA SI CONFERMA LA MODIFICA

– TENERE PREMUTO I PULSANTI TENERE PREMUTO I PULSANTI A+B+D A+B+D PER USCIRE DALLA PER USCIRE DALLA PROGRAMMAZIONE OPPURE TOGLIERE ALIMENTAZIONE PROGRAMMAZIONE OPPURE TOGLIERE ALIMENTAZIONE ELETTRICAELETTRICA

MENUMENU’’ PROGRAMMAZIONE PROGRAMMAZIONE

DD

A+B+A+B+DD

H o GH o GA o BA o B

Page 30: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

SCHEDA INTEGRATA SIT : LISTA PARAMETRISCHEDA INTEGRATA SIT : LISTA PARAMETRI

DISPLADISPLAYY

REMOTREMOTOO

FUNZIONEFUNZIONE SETTAGGIOSETTAGGIO

P01P01 TIPO CALDAIA TIPO CALDAIA 0000 : Nessun Modello selezionato => Er 99 : Nessun Modello selezionato => Er 99

0101 : Rinnova Cond 25 S (1°e 2° serie: M160 2025 : Rinnova Cond 25 S (1°e 2° serie: M160 2025 SM)SM)

0303 : Rinnova Cond 35 S (1°e 2° serie: M160 3035 : Rinnova Cond 35 S (1°e 2° serie: M160 3035 SM)SM)

10 10 : Rinnova Cond 12 SV (2°serie: M160 1212 SV) : Rinnova Cond 12 SV (2°serie: M160 1212 SV) (con NTC bollitore)(con NTC bollitore)

1212 : Rinnova Cond 25 SV (1°serie: M160 2525 SV) : Rinnova Cond 25 SV (1°serie: M160 2525 SV) (con NTC bollitore)(con NTC bollitore)

1313 : Rinnova Cond 30 SV (1° serie: M160 3030 SV) : Rinnova Cond 30 SV (1° serie: M160 3030 SV) (con NTC bollitore)(con NTC bollitore)

14 14 : Rinnova Cond 12 SV (2°serie: M160 1212 SV) : Rinnova Cond 12 SV (2°serie: M160 1212 SV) (con(con

termostato bollitore)termostato bollitore)

1616 : Rinnova Cond 25 SV (1° serie: M160 2525 SV) : Rinnova Cond 25 SV (1° serie: M160 2525 SV) (con termostato bollitore)(con termostato bollitore)

1717 : Rinnova Cond 30 SV (1° serie: M160 3030 SV) : Rinnova Cond 30 SV (1° serie: M160 3030 SV) (con termostato bollitore)(con termostato bollitore)

2323 : :Rinnova Solar Tank 25 S (T 160 2525) Rinnova Solar Tank 25 S (T 160 2525)

2424 : :Rinnova Solar Tank 35 S (T 160 3035)Rinnova Solar Tank 35 S (T 160 3035)

Page 31: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

DISPLADISPLAYY

REMOTREMOTOO

FUNZIONEFUNZIONE SETTAGGIOSETTAGGIO

P01P01 TIPO CALDAIA TIPO CALDAIA 2727: : Rinnova Cond 25 SV (2°serie: M160 2025 SV) (con Rinnova Cond 25 SV (2°serie: M160 2025 SV) (con NTC bollitore)NTC bollitore)

2828: : Rinnova Cond 35 SV (2°serie: M160 3035 SV) (con Rinnova Cond 35 SV (2°serie: M160 3035 SV) (con NTC bollitore)NTC bollitore)

3030: : Rinnova Cond 25 SV (2°serie: M160 2025 SV) (con Rinnova Cond 25 SV (2°serie: M160 2025 SV) (con termostato bollitore)termostato bollitore)

3131: : Rinnova Cond 35 SV (2°serie: M160 3035 SV) (con Rinnova Cond 35 SV (2°serie: M160 3035 SV) (con termostato bollitore)termostato bollitore)

33 :33 : Inovia Cond IN25 S (M261 2025 SM) Inovia Cond IN25 S (M261 2025 SM)

34 :34 : inovia Cond IN 35 S ( M261 3035 SM) inovia Cond IN 35 S ( M261 3035 SM)

3535 : Inovia Cond 25 S (M260 2025SM) : Inovia Cond 25 S (M260 2025SM)

3737 : Inovia Cond 35 S (M260 3035 SM) : Inovia Cond 35 S (M260 3035 SM)

4545 : : Inovia Cond 16 SV (M260 1616 SV) (con NTC Inovia Cond 16 SV (M260 1616 SV) (con NTC bollitore)bollitore)

4646 : : Inovia Cond 25 SV (M260 2025 SV) (con NTC Inovia Cond 25 SV (M260 2025 SV) (con NTC bollitore)bollitore)

4747 : : Inovia Cond IN 16 SV (M261 1616 SV) (con NTC Inovia Cond IN 16 SV (M261 1616 SV) (con NTC bollitore)bollitore)

4848 : : Inovia Cond IN 25 SV (M260 2025 SV) (con NTC Inovia Cond IN 25 SV (M260 2025 SV) (con NTC bollitore)bollitore)

SCHEDA INTEGRATA SIT : LISTA PARAMETRISCHEDA INTEGRATA SIT : LISTA PARAMETRI

Page 32: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

DISPLADISPLAYY

REMOTREMOTOO

FUNZIONEFUNZIONE SETTAGGIOSETTAGGIO

P01P01 TIPO CALDAIA TIPO CALDAIA 4949 :: Inovia Cond 35 SV (M260 3035SV) (con NTC Inovia Cond 35 SV (M260 3035SV) (con NTC bollitore)bollitore)

5151 : : Inovia Cond 16 SV (M260 1616SV) (con termostato Inovia Cond 16 SV (M260 1616SV) (con termostato bollitore)bollitore)

5252 : : Inovia Cond 25 SV (M260 2025SV) (con termostato Inovia Cond 25 SV (M260 2025SV) (con termostato bollitore)bollitore)

5353 : : Inovia Cond IN 16 SV (M261 16SV) (con termostato Inovia Cond IN 16 SV (M261 16SV) (con termostato bollitore)bollitore)

5353 : : Inovia Cond IN 25 SV (M261 25SV) (con termostato Inovia Cond IN 25 SV (M261 25SV) (con termostato bollitore)bollitore)

5555 :: Inovia Cond 35 SV (M260 3035SV) Inovia Cond 35 SV (M260 3035SV) (con termostato (con termostato bollitore)bollitore)

56 56 : Inovia Cond Max 20/25 S (M262 20/25 SM): Inovia Cond Max 20/25 S (M262 20/25 SM)

57 57 : Inovia Cond Max 30/35 S (M262 30/35 SM): Inovia Cond Max 30/35 S (M262 30/35 SM)

SCHEDA INTEGRATA SIT : LISTA PARAMETRISCHEDA INTEGRATA SIT : LISTA PARAMETRI

Page 33: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

DISPLAYDISPLAY

REMOTOREMOTOFUNZIONEFUNZIONE SETTAGGIOSETTAGGIO

P02P02 TIPO SENSORE ACQUATIPO SENSORE ACQUA

TRASDUTTORE FLUSSOSTATOTRASDUTTORE FLUSSOSTATO

PRESSOSTATO FLUSSIMETROPRESSOSTATO FLUSSIMETRO

0000 = PRESSOSTATO + FLUSSOSTATO(M160 = PRESSOSTATO + FLUSSOSTATO(M160 1°serie)1°serie)

0000 = SV CON PRESSOSTATO (M160 1°serie+ = SV CON PRESSOSTATO (M160 1°serie+ M262)M262)

0101 = TRASDUTTORE + FLUSSIMETRO = TRASDUTTORE + FLUSSIMETRO

(M260, M160 2°serie)(M260, M160 2°serie)

0101 = SV CON TRASDUTTORE (M260, M160 2°serie) = SV CON TRASDUTTORE (M260, M160 2°serie)

0202 = TRASDUTTORE + FLUSSOSTATO (T160) = TRASDUTTORE + FLUSSOSTATO (T160)

0303 = PRESSOSTATO + FLUSSIMETRO = PRESSOSTATO + FLUSSIMETRO

P03P03 GESTIONE VELOCITA’ GESTIONE VELOCITA’ CIRCOLATORECIRCOLATORE

0000 = SEMPRE ALLA MASSIMA = SEMPRE ALLA MASSIMA

0101 = SEMPRE ALLA MINIMA = SEMPRE ALLA MINIMA

0202 = SELEZIONE AUTOMATICA = SELEZIONE AUTOMATICA

P04P04 GESTIONE ZONEGESTIONE ZONE 0000 = 1 ZONA (solo TA o solo remoto) = 1 ZONA (solo TA o solo remoto)0101 = TA + REMOTO e VALVOLA DI ZONA = TA + REMOTO e VALVOLA DI ZONA

(set temperatura + alta) (set temperatura + alta) (SOLO M260)(SOLO M260)

0202 = TA + REMOTO e VALVOLA DI ZONA = TA + REMOTO e VALVOLA DI ZONA

(set temperatura + bassa) (set temperatura + bassa) (SOLO M260)(SOLO M260)

03 03 = T160= T160

P05P05 TIPO GAS TIPO GAS 0000 : METANO : METANO

0505 : GPL : GPL

SCHEDA INTEGRATA SIT : LISTA PARAMETRISCHEDA INTEGRATA SIT : LISTA PARAMETRI

Page 34: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

DISPLAYDISPLAY

REMOTOREMOTOFUNZIONEFUNZIONE SETTAGGIOSETTAGGIO

P06P06 NON UTILIZZATONON UTILIZZATO

P07P07 MASSIMA TEMPERATURA MASSIMA TEMPERATURA RISCALDAMENTO (°C)RISCALDAMENTO (°C)

45÷8545÷85 (DEFAULT 85°C)(DEFAULT 85°C)

P08P08 RIPRISTINO PARAMETRI RIPRISTINO PARAMETRI DI FABBRICADI FABBRICA

04 04 : : TUTTI I PARAMETRI RITORNANO AL TUTTI I PARAMETRI RITORNANO AL SETTAGGIO DI DEFAULT AD ECCEZIONE DI (Pr 01 SETTAGGIO DI DEFAULT AD ECCEZIONE DI (Pr 01 & Pr 05)& Pr 05)

3939 : : RESET DI TUTTI I PARAMETRI:RESET DI TUTTI I PARAMETRI:•Pr 05=00 => G20;Pr 05=00 => G20;•Pr 01=00 => Er 99 => NECESSARIO IMPOSTARE Pr 01=00 => Er 99 => NECESSARIO IMPOSTARE TIPO CALDAIATIPO CALDAIA

P09P09 INGRESSO MODALITA’ INGRESSO MODALITA’ SPAZZACAMINO PER SPAZZACAMINO PER TARATURA CALDAIATARATURA CALDAIA

0000 = FUNZIONE NON ATTIVA = FUNZIONE NON ATTIVA

0101 = MINIMO SANITRIO = MINIMO SANITRIO

0202 = MINIMO RISCALDAMENTO = MINIMO RISCALDAMENTO

0303 = MASSIMO RISCALDAMENTO = MASSIMO RISCALDAMENTO

0404 = MASSIMO SANITARIO = MASSIMO SANITARIO

SCHEDA INTEGRATA SIT : LISTA PARAMETRISCHEDA INTEGRATA SIT : LISTA PARAMETRI

Page 35: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

DISPLAYDISPLAY

REMOTOREMOTOFUNZIONEFUNZIONE SETTAGGIOSETTAGGIO

P10P10 RITARDO RIACCENSIONE RITARDO RIACCENSIONE IN RISCALDAMENTOIN RISCALDAMENTO

00÷10000÷100 (0÷600 sec) (0÷600 sec) (DEFAULT 30 = 3 min)(DEFAULT 30 = 3 min)

P11P11 POST CIRCOLAZIONE IN POST CIRCOLAZIONE IN RISCALDAMENTORISCALDAMENTO

00÷10000÷100 (0÷600 sec) (0÷600 sec) (DEFAULT 10 = 1 min)(DEFAULT 10 = 1 min)

P12P12 POTENZA IN POTENZA IN RISCALDAMENTO %RISCALDAMENTO %

00 ÷10000 ÷100

00 00 == SOLO MINIMA POTENZASOLO MINIMA POTENZA

100 100 == NESSUNA RIDUZIONE (VEDI NESSUNA RIDUZIONE (VEDI DIAGRAMMA SU LIBRETTO CALDAIADIAGRAMMA SU LIBRETTO CALDAIA

SCHEDA INTEGRATA SIT : LISTA PARAMETRISCHEDA INTEGRATA SIT : LISTA PARAMETRI

Page 36: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

DISPLAYDISPLAY

REMOTOREMOTOFUNZIONEFUNZIONE SETTAGGIOSETTAGGIO

P13P13 MODO POMPA MODO POMPA 0000 : ON SU RICHIESTA(DEFAULT) : ON SU RICHIESTA(DEFAULT)

0404 : SEMPRE IN FUNZIONE : SEMPRE IN FUNZIONE

P14P14 POTENZA DI POTENZA DI ACCENSIONEACCENSIONE

00÷10000÷100 (0÷100%) (0÷100%)

(DEFAULT: 50)(DEFAULT: 50)

P15P15 IMPOSTAZIONE VALORE K IMPOSTAZIONE VALORE K (SETTAGGIO SONDA (SETTAGGIO SONDA ESTERNA) ESTERNA)

00 00 = OFF (DEFAULT)= OFF (DEFAULT)

01 – 60 (Pr15=10=K1 Pr15=60=K601 – 60 (Pr15=10=K1 Pr15=60=K6

P16P16 POTENZA MINIMA POTENZA MINIMA RISCALD.RISCALD.

00÷10000÷100 (0÷100%) (0÷100%)

(DEFAULT: 00)(DEFAULT: 00)

P17**P17** SPEGNIMENTO IN SPEGNIMENTO IN SANITARIOSANITARIO

0000 = SET FISSO (65° C) (DEFAULT) = SET FISSO (65° C) (DEFAULT)

01 = SET POINT + 5°C01 = SET POINT + 5°C

02 = SET POINT + 3°C 02 = SET POINT + 3°C

P18P18 ABILITAZIONE NTC SU ABILITAZIONE NTC SU RITORNO RITORNO RISCALDAMENTORISCALDAMENTO

0000 : : NON PRESENTENON PRESENTE

01 : PRESENTE01 : PRESENTE

** NB: Se la scheda viene settata per bollitore con sonda ntc allora P17 determina la frequenza di attivazione della funzione antilegionella

P17 = 01 ANTILEGIONELLA OGNI 2 GGP17 = 01 ANTILEGIONELLA OGNI 2 GG

P17= 02 ANTILEGIONELLA OGNI 3 GGP17= 02 ANTILEGIONELLA OGNI 3 GG

SCHEDA INTEGRATA SIT : LISTA PARAMETRISCHEDA INTEGRATA SIT : LISTA PARAMETRI

Page 37: Service Inovia Cond MAX CIRCUITO COMANDO Inovia Cond MAX CIRCUITO COMANDO.

ServicServicee

RinNOVA COND X, Inovia Cond , Inovia IN: circuito comandoRinNOVA COND X, Inovia Cond , Inovia IN: circuito comando

DISPLAYDISPLAY

REMOTOREMOTOFUNZIONEFUNZIONE SETTAGGIOSETTAGGIO

P24P24 DUTY CICLEDUTY CICLE 0 ÷ 30 0 ÷ 30 (DEFAULT 0)(DEFAULT 0)

0 0 = VALVOLA DI ZONA SEMPRE APERTA CON = VALVOLA DI ZONA SEMPRE APERTA CON RICHIESTA RICHIESTA

1 ÷ 30 1 ÷ 30 MINUTI DEL CICOLO DI MINUTI DEL CICOLO DI APERTURA/CHIUSURA DELLA VALVOLA DI APERTURA/CHIUSURA DELLA VALVOLA DI ZONAZONA

P27P27 TEMPERATURA MINIMA TEMPERATURA MINIMA RISCALDAMENTORISCALDAMENTO

25÷4525÷45 (DEFAULT 25°) (DEFAULT 25°)

P28P28 SCADENZA SCADENZA MANUTENZIONEMANUTENZIONE

00 ÷ 48 00 ÷ 48 (DEFAULT 12 MESI)(DEFAULT 12 MESI)

P29P29 NTC INGRESSO NTC INGRESSO SANITARIOSANITARIO

0000 = NON PRESENTE = NON PRESENTE

0101 = PRESENTE = PRESENTE

0404 = CENTRALINA SOLARE COLLEGATA = CENTRALINA SOLARE COLLEGATA

P30P30 PRESSIONE IMPIANTO PRESSIONE IMPIANTO RISCALDAMENTO RISCALDAMENTO CORRETTA CORRETTA

1010 (sotto 1,0 bar si accende l’icona di (sotto 1,0 bar si accende l’icona di richiesta carico) (richiesta carico) (SOLO M260)SOLO M260)

SCHEDA INTEGRATA SIT : LISTA PARAMETRISCHEDA INTEGRATA SIT : LISTA PARAMETRI