Page 3: Session: 2017 ICC A117.1 Update Significant Changes

Requirements

Scoping :

“What, Where

and How Many”

2015 IBC and IEBC

Technical:

“How”

ICC/ANSI A117.1-

2009

3

Page 4: Session: 2017 ICC A117.1 Update Significant Changes

ICC A117.1 Accessible and

Usable Buildings and Facilities

Standard & Commentaries.

History, reasoning and

examples

Technical assistance via

phone, email or letter.

4

Page 5: Session: 2017 ICC A117.1 Update Significant Changes

Role of the Code Official

Enforce the locally adopted building code and

any local or state laws

Does not enforce ADA or FHA.

5

Page 6: Session: 2017 ICC A117.1 Update Significant Changes

Human Factor

Considerations Body Size

Functional abilities

Page 7: Session: 2017 ICC A117.1 Update Significant Changes

Basis for A117.1 - Dimensions

of Adult-Sized Wheelchair

7

Page 8: Session: 2017 ICC A117.1 Update Significant Changes

2017 ICC A117.1

Revisions

Study on Anthropometry of

Wheeled Mobility

Sponsored by the US Access

Board

Including persons using

manual wheelchairs,

motorized wheelchairs &

scooters

http://www.udeworld.com/an

thropometrics.html

8

Page 9: Session: 2017 ICC A117.1 Update Significant Changes

Human Factor Anthropometrics

9

Page 10: Session: 2017 ICC A117.1 Update Significant Changes

Existing building and facilities

New sizes will not apply to existing buildings or

facilities

Will apply to new construction and additions

Definition:

existing building. A building erected prior to the

date of adoption of this standard, or one for which a

legal building permit has been issued.

10

Page 11: Session: 2017 ICC A117.1 Update Significant Changes

Building Blocks

Clear floor space

Turning space

Page 12: Session: 2017 ICC A117.1 Update Significant Changes

Wheelchair space

Existing – 48” New – 52”

12

Page 13: Session: 2017 ICC A117.1 Update Significant Changes

Turning space

Existing – 60” New – 67”

13

Page 14: Session: 2017 ICC A117.1 Update Significant Changes

Turning space

Existing New

14

Page 15: Session: 2017 ICC A117.1 Update Significant Changes

Turning space overlap

Existing New

15

Page 16: Session: 2017 ICC A117.1 Update Significant Changes

Turn comparison

Existing New

16

Page 17: Session: 2017 ICC A117.1 Update Significant Changes

No changes

Reach range

Knee and toe clearance

17

Page 18: Session: 2017 ICC A117.1 Update Significant Changes

Accessible Routes

90 degree turn

180 degree turn

Turning space

Doors

Exterior routes

Platform lifts

Page 19: Session: 2017 ICC A117.1 Update Significant Changes

90 degree turnExisting New

19

Page 20: Session: 2017 ICC A117.1 Update Significant Changes

Turn around obstruction

Existing New

20

Page 21: Session: 2017 ICC A117.1 Update Significant Changes

Turn around obstruction

Existing New

21

Page 22: Session: 2017 ICC A117.1 Update Significant Changes

Passing space

Existing New

22

Page 23: Session: 2017 ICC A117.1 Update Significant Changes

Impact - Turns in a small store

23

Page 24: Session: 2017 ICC A117.1 Update Significant Changes

Impact - Multi-stall layout

24

Page 25: Session: 2017 ICC A117.1 Update Significant Changes

Impact - Dining room layout

25

Page 26: Session: 2017 ICC A117.1 Update Significant Changes

Doors:404.2.3 Obstructions to the Maneuvering

Clearance

Removed from 2017 A117.1

Prohibits the use of knee and toe

clearances (i.e., under sinks or

counters) when overlapping

maneuvering space at a door.

The intent is that users do not

need to reach over an

obstruction to operate the

hardware.

26

Page 27: Session: 2017 ICC A117.1 Update Significant Changes

Door maneuvering size

Existing – 48” New – 52”

27

Page 28: Session: 2017 ICC A117.1 Update Significant Changes

Vestibules

Existing New

28

Page 29: Session: 2017 ICC A117.1 Update Significant Changes

Exterior route

Existing New

29

Page 30: Session: 2017 ICC A117.1 Update Significant Changes

Curb Ramps

Perpendicular Parallel

30

Page 31: Session: 2017 ICC A117.1 Update Significant Changes

Blended Transitions

31

Page 32: Session: 2017 ICC A117.1 Update Significant Changes

Platform Lifts

Change in size for vertical

platform lift for new clear floor

space size – 36” x 52”

Incline platform lift with barriers

permitted to use 36” x 48”

32

Page 33: Session: 2017 ICC A117.1 Update Significant Changes

General Site and Building

Elements Parking

Meters

Electrical Charging Stations

Route across parking lot

Windows

Page 34: Session: 2017 ICC A117.1 Update Significant Changes

Angled street parking

34

Page 35: Session: 2017 ICC A117.1 Update Significant Changes

Parallel street parking

35

67 min

Page 36: Session: 2017 ICC A117.1 Update Significant Changes

Parking meters and pay stations

Clear floor space

Reach range

Operable parts

Displays

36

Page 37: Session: 2017 ICC A117.1 Update Significant Changes

Electric vehicle charging

stations

Clear floor space

Reach ranges

Operable parts

Route not obstructed

by cord or barriers

37

Page 38: Session: 2017 ICC A117.1 Update Significant Changes

Routes across parking lots

Protected accessible route across parking lots

38

Page 39: Session: 2017 ICC A117.1 Update Significant Changes

Windows One window per room except kitchens and

bathrooms

emergency escape and rescue

natural ventilation

Four forces on a window – locking, unlocking,

opening and closing

Locking/unlocking are operable parts

Opening/closing - AAMA 513

39

Page 40: Session: 2017 ICC A117.1 Update Significant Changes

Plumbing Elements and

Facilities

Water bottle filler

Toilet stalls

Page 41: Session: 2017 ICC A117.1 Update Significant Changes

Bottle filling stations

41

Page 42: Session: 2017 ICC A117.1 Update Significant Changes

Stall options

End or row stall or new alternative stall

42

Page 43: Session: 2017 ICC A117.1 Update Significant Changes

Partition

43

Page 44: Session: 2017 ICC A117.1 Update Significant Changes

Communication Elements

and Features

Visual relay service

Page 45: Session: 2017 ICC A117.1 Update Significant Changes

Visual relay service booth

Seating

Privacy enclosure

Two-way video

communication

system

Background

45

Page 46: Session: 2017 ICC A117.1 Update Significant Changes

Special Rooms and Spaces

Assembly seating

Sign language interpreter station

Kitchens

Classroom acoustics

Page 47: Session: 2017 ICC A117.1 Update Significant Changes

Assembly Areas:Definitions

wheelchair space: A space for a single

wheelchair and its occupant.

wheelchair space locations: A space for a

minimum of a single wheelchair and the

associated companion seating. Wheelchair

space locations can contain multiple wheelchair

spaces and associated companion seating.

47

Page 48: Session: 2017 ICC A117.1 Update Significant Changes

Wheelchair space

in assembly spaces

Existing New

48

Page 49: Session: 2017 ICC A117.1 Update Significant Changes

Assembly Areas

49

Page 50: Session: 2017 ICC A117.1 Update Significant Changes

Dinner Theaters & Lecture Halls

Dispersion based on

assembly seating to

view an event

Not work surface or

dining room

dispersion throughout

50

Page 51: Session: 2017 ICC A117.1 Update Significant Changes

Sign language interpreters

stations

Area to stand

Viewing angle

for audience

Illumination

Backdrop

51

Page 52: Session: 2017 ICC A117.1 Update Significant Changes

Kitchen Island

52

Page 53: Session: 2017 ICC A117.1 Update Significant Changes

Kitchenettes

Requires 40 inch minimum

clearance between cabinets,

appliance and any walls at

kitchenettes.

Pass thru not required for

kitchenette.

Work surface not required in

kitchenette.

Parallel approach at sink.

Turning space in the room

where within an Accessible or

Type A unit (may not be inside

the kitchenette).53

Page 54: Session: 2017 ICC A117.1 Update Significant Changes

Operable parts

Kitchen Outlet Exception:

Over counter top in a

corner between

appliances

Counter top area does

not exceed 9 square

feet maximum.

54

Page 55: Session: 2017 ICC A117.1 Update Significant Changes

Classroom acousticsClassrooms <20,000 cubic feet

55

Learning Space Greatest one hour average

sound level of exterior

source background noise

Greatest one hour average

sound level of interior

source background noise

Maximum reverberation

times for sound pressure

levels in octave bands with

frequencies of 500, 1000

and 2000 Hz.

Classrooms with an

enclosed volume of <=

10,000 cubic feet

35 dBA/55 dBC 35 dBA/55 dBC 0.6 seconds

Classrooms with an

enclosed volume of >

10,000 cubic feet and <=

20.000 cubic feet

35 dBA/55 dBC 35 dBA/55 dBC 0.7 seconds

Classroom Acoustics Requirements

Page 56: Session: 2017 ICC A117.1 Update Significant Changes

Furnishings and Equipment

Service windows

Gaming machines and tables

Page 57: Session: 2017 ICC A117.1 Update Significant Changes

Service windows

Applicable to public side

(not employee side)

Side or front approach

Equal customer counter

Maximum barrier height

to allow for face-to-face

contact between

employee and customer

Allowance for security

windows

57

Page 58: Session: 2017 ICC A117.1 Update Significant Changes

Service windows

58

Page 59: Session: 2017 ICC A117.1 Update Significant Changes

Gaming machines and tables

Clear floor space next

to gaming table or

machine

59

Page 60: Session: 2017 ICC A117.1 Update Significant Changes

Recreational Facilities Shooting facilities

Page 61: Session: 2017 ICC A117.1 Update Significant Changes

Elevated Shooting Platform

Exception:

500 sq.ft. maximum

Elevated over 12 feet

61

Page 62: Session: 2017 ICC A117.1 Update Significant Changes

Dwelling Units and Sleeping

Units Accessible units

Type B units

Page 63: Session: 2017 ICC A117.1 Update Significant Changes

Charging stations; Mattress

height

Charging Station:

Charge a motorized

wheelchair

Option at assembly

wheelchair space

Same space as

transfer space next to

bed in Accessible hotel

or dorm rooms

Mattress height

63

Page 64: Session: 2017 ICC A117.1 Update Significant Changes

Type B units

Keep old size

Match FHA

64

Page 65: Session: 2017 ICC A117.1 Update Significant Changes

Process for Change

• International Codes

• ICC A117.1

65

Page 66: Session: 2017 ICC A117.1 Update Significant Changes

International Codes –Code Change Process Logistics

I-Code published every 3 years.

15 codes split into two groups: A, B.

Single cycle for each group

Code Development

Final Action Hearings

Repeat

2021 available in fall of 2020.

66

Page 67: Session: 2017 ICC A117.1 Update Significant Changes

A117.1 Standard:

Change Process Logistics

5 year development cycle.

One cycle of development

between editions

Years 1 and 2: study groups

Years 3, 4 and 5: processing

changes and publication.

Repeat

Latest edition is 2017

not referenced in 2018 I-Codes