IShron, McLaurin[A]101.2 M O D IBC - Adds 4-story townhomes to exception
A035
IIShron, McLaurinC202 M O D IECC (C) - Adds 4-story townhomes to exception
A035
IIIShron, McLaurinR202 M O D IECC (R) - Adds 4-story townhomes to exception
A035
IVShron, McLaurinR101.2 M O D IRC - Adds 4-story townhomes to exception
A 044 Roetzel & Andre101.3.1 H S AIBC - Life Safety. does not depend on a single fire protectionsystem, or fire-resistance-rated material, system or assembly
A045
INAHB C101.3 H S A IECC (C) - deletes "over the useful life of each building."
A045
IINAHB R101.3 H S A IECC (R) - deletes "over the useful life of each building."
A046
INAHB C102.1.1 H S A
IECC (C) - Deletes: "The requirements identified as "mandatory" in Chapter 4 shall be met."
Concept
SIGNIFICANT CODE CHANGE PROPOSALS ICC GROUP B 2016Impact: H=High, M=Moderate, L=Low, N=None
Position: O=Oppose, S=Support, MO=Mild Opposition, MS=Mild Support, N = NoneAction: A=Approve, D=Disapprove, AM=Approve as Modified, W=Withdrawn
Desi
gnat
ion
Num
ber Proponent
Sect
ion
Impa
ct
PCA
Posi
tion
Committee
Publ
ic C
omm
ent Public
Fina
l Act
ion
Adm - ADMINISTRATION
A046
IINAHB R102.1.1 H S A
IECC (R) - Deletes: "The requirements identified as "mandatory" in Chapter 4 shall be met."
A 077 AWC [A]107 H S A XIBC, IEBC - protection of structural systems of balconies from moisture - Requires public comment to limit to structural systems susceptible to damage - Dennis Richardson
A 087 AWC 110.3.6 H S A XIBC, IEBC - Weather exposed balcony Would like to see "and the structural framing is designed to be protected"
A 094 ICC Ref. Std. H S AReferenced standards update - includes ACI 332, TMS 402, 403, and 602
S 00 AWC 1401 M O D Reduces effects on balconies - advantage wood
S 015Wanda Edwards
1504.5 M O DEdges of low-sloped roofs - reduces cost for bituminous systems
S 019 SPRI 1504.4 M O DIncreases areas where aggregate roof systems are not allowed (from hurricane to wind-borne)
S 020National Asphalt Roofing Assn
1504.8 M O DAggregate roof systems - is there an 'approved method' that is industry accepted?
S 021 BCAC 1504.8 M S AAggregate roof systems - clarification that no aggregate in hurricane zones
S 022 BCAC 1504.9 M S ADisallow aggregate ballasted roof in 250mph wind zones on critical blds - concrete system +
IBC - STRUCTURAL
*** END OF SECTION Adm - ADMINISTRATION ***
S 024 FEMA 1504.9 M S A Loads on gutters - plus to concrete systems (see also S16)
S 100 AWC 1607 M O DOversimplifies design of fire walls - oppose as the criteria does not require gravity loads to be concurrent with lateral fire loads - gravity loads are always present - slight
S 101 Ali Fattah 1607 M S ARequire gravity loads to be concurrent with lateral fire loads - slight advantage to concrete systems
S 106 NCSEA 1609 H S AIncreases minimum thickness of wood panel for 'missile test' - advantage cement systems
S 136 SKG 1705.3 H S ASpecial inspections for welding with rebar - intends to reverse a technical change caused by an organizational change in the 2015 IBC - submitted by S.K. Ghosh
S 137 NCSEA 1705.11.1 H S AAdds special inspections for wood construction - wood previously did not require much in special inspections - proposal brings wood to the similar level as concrete or steel
S 138 NCSEA 1705.5.2 H S AAdds special inspection for wood trusses - on par with other construction materials
S 191 GeoCoalition 1807 M S AAdds that retaining walls built-up of discrete elements (such as mortar less masonry) shall have a load-transfer mechanism that prevents dislodgement - plus to mortar
S 227 SKG 1810.3.8 M S AUpdates seismic design of precast piles to latest approach - increases confinement requirements - increases resiliency of piles to earthquakes - submitted by S.K. Ghosh
S 242 SKG 1613 H S AAdds modern seismic precast diaphragm design procedures to the code by reference to ASCE 7-16 (self)
S 244 MACS 2101 H S A Updates TMS references for masonry
S 245 MACS 2103.1 H S A Updates ASTM references for masonry
S 256 NYS CBSC 2303.1 M O DProposal deletes the requirement for a 'grade mark' or 'certificate of inspection by a lumber grading or inspection agency' for small mills - could permit ungraded lumber
S 264 GBH 2303 H O DEliminate testing for fire retardant treaded wood products that have been treated by other than a pressure process
S 265Hoover Treated Wood Products
2303 M S A Increases the labeling requirements for wood products
CE 021 ASHRAEC301.1 tables and
M S ADeletes climate zone figure and tables in favor of a new reference to ASHRAE 169-2013
CE 023 DOEC409 new; R407
H S AAdds new compliance option for conditioned passive buildings.
CE 039 Conner C401.2 M O DRetains 2015 IECC climate zones in lieu of ASHRAE updated maps
CE 071 MACSTable C402.1.4
M S ACorrects U factor requirements for mass walls and mass floors.
CE 083 MACS C402.3 H S AWall R-values - fixes above grade walls R values and U factors
CE 087Foam Sheathing Committee of
C402.2.7 new; R402.2.1
M O DAirspaces shall be unventilated - Vented and weeped masonry walls have no significant reduction in R-value - proponent to show test otherwise - coordinated with MACS
CE 104EPDM Roofing Assn
C402.5, C402.5.1
M S A Air barrier - inside or outside of thermal barrier.
*** END OF SECTION IBC - STRUCTURAL ***
IECC-COMMERCIAL ENERGY
CE 285 SeattleC503.2, C505.1
M O D Maintains minimum UA for performance compliance
RE 023ARES Consulting
Table R402.1.2
L O DNew options for mass wall insulation values Concept of splitting interior and exterior mass is good but increases R-values for interior mass
RE 051American Wood Council
R402.2.5 M MS AMAdds CLT & HT wood into mass wall section (solid wood elements)
RE 052 MACS R402.2.5 H S A Corrects heat capacity for mass walls
F 036Robert Davidson
IFC: 503.1.2, 50
M S ADoes not permit an increase in fire access distance when using 13R or 13D
F 037 MACSIFC: 503.7 (New)
M S A Requires 2 access roads for type III, IV and V
F 038 Phoenix FDIFC: 507.5.7 (Ne
M S AMRequires 2 access roads during construction when combustible arrive. Needs works to specify combustibles
F 328Robert Davidson
IFC: 3304.5.
H S ARequires fire watch for combustible construction over 2 stories.F
*** END OF SECTION IECC - COMMERCIAL ***
IECC-RESIDENTIAL ENERGY
*** END OF SECTION IECC - RESIDENTIAL ***
IFC - FIRE
F 329 San Diego3304.5.1 (New);
H S A Requires fire watch for combustible construction over 40 ft.
F 333Robert Davidson
IFC: 3310.1, 331
H S ARequires increased fire dept. access for combustible construction
F 334 Mark NowakIFC: 3310.1.
H S A Prefer F333
F 336 Stephen Skalko3314.2 (New) (IB
H S A sprinklers active during construction
RB 012 San Diego R202 M S AClarifies measuring the distance as from face of wall covering and not from foundation wall
RB 015 R. Davidson R202 L S A Adds clear width of yard to townhouse definition
RB 018OR Earthquake Awareness
R301.2 M W D Replaces SDC with Lateral design strength maps
RB 020 IBHS R301.2 H S A Coordinates wind with ASCE 7-16 - increasing wind speed
RB 023 BCAC 301.2.2 L W D Seismic design - Clarification seems confusing
RB 026 Seattle 301.5 M S A Increases balcony loads by 1.5
*** END OF SECTION IFC ***
IRC - RESIDENTIAL
RB 027 WABO 301.5 M S A Increases balcony loads 40 to 60
RB 031 MACS 302.1 M S A Adds ACI/TMS 216.1
RB 032 CO Code Consul302.1 M S AAdds compliance via IBC Chapter 7 which includes ACI/TMS 216.1
RB 036 S NV ICC 302.1.1 H O DAllows reduction in fire separation distance up to 4" for unprotected wall coverings. Could be approve as modified if non-combustible
RB 038 R. Davidson 302.2 M O D Removes 2-hr wall where sprinklers not required
RB 043 San Diego 202 M S A Continuity of common walls
RB 044 CO Code Consul302.2 M S AMTwo separate 1-hour walls - needs to add structural stable two- hour wall
RB 045 R. Davidson 3022.2. M O D Allows FRTW for parapets
RB 047 R. Davidson 302.2.2 M O D Removes parapets
RB 048 R. Davidson 302.2 M O D Removes structural integrity
RB 049 San Diego 302.2 M S A Common wall structural stability
RB 050 R. Davidson 302.3 M O D Reduces fire protection from 1 hr to 1/2 hour
RB 052CO Code Consulting
302.3 H O DSeems to reduce 2-hr to 1-hr, also would benefit by adding ACI/TMS 216.1
RB 069Structural Building Components
302.13 M W A Floor fire protection - dimensional wood
RB 084 R. Davidson 309.1 H O DGarage and carport floor surfaces - permits asphalt in garages
RB 152Green Science Policy Institute
316.5.14 M O D No fire protection for below grade foam
RB 153Altamonte Springs
316.6 H O DAllows combustible fro fire protection of combustible foam sheathing
RB 163 R. Davidson 163 H O D Moves storm shelters to appendix
RB 166 BCAC 325.1 H O D Habitable attics - not a story
RB 196 R. Davidson 506.2.3 L O D Removes requirement for vapor barrier for slab on ground
RB 296 PCA 702.1 L S A Adds C1157 cement for stucco
RB 303APA, Engineered Wood
703.8.4 M S A Brick veneer ties to structural sheathing
*** END OF SECTION IRC ***
IWUIC - WILDLAND-URBAN INTERFACE
W 002 PCA 504.5 M AM AM Removes log home and heavy timber. Needs modification
W 003 AWC 504.5 H O D Permits assemblies passing ASTM E2707 test
W 006 AWC 505.5 M W D Exterior walls, Class 2
W 009 AWC (NEW) IW M O D California standards
*** END OF SECTION IWUIC ***
Desi
red
Com
mitt
ee
Asse
mbl
y
Desi
red
Asse
mbl
y
A 001 I
BCAC, SEHPCAC 202 N N N IBC - Adds stories to heights and areas to definition of Addition
A 001 II
BCAC, SEHPCAC C202 N N N IECC (C) - Adds stories to heights and areas to definition of Addition
A 001 III
BCAC, SEHPCAC R202 N N N IECC (R) - Adds stories to heights and areas to definition of Addition
A 001 IV
BCAC, SEHPCAC R202 N N N IRC - Adds stories to heights and areas to definition of Addition
A 002 I
PMGCAC, SEHPCAC 202 N N N ISPSC - Adds any in front of construction for alterations
A 002 II
PMGCAC, SEHPCAC C202 N N N IECC (C) - Removes language on "requiring permits" for alternations
A 002 III
PMGCAC, SEHPCAC R202 N N N IECC (R) - Removes language on "requiring permits" for alternations
A 002 IV
PMGCAC, SEHPCAC R202 N N N IRC - Removes language on "requiring permits" for alternations
A 003 BCAC, NCSEA, Seattle
202 N N N IEBC - Removes classifications for alterations
A 004 I
BCAC, SEHPCAC, PMGCAC
202 N N N ISPSC & IEBC - Removes "Authority having jurisdiction" and leaves as code official for
A 004 II
BCAC, SEHPCAC, PMGCAC
202 N N N IECC (C) - Changes approved to "acceptable to code official"
A 004 III
BCAC, SEHPCAC, PMGCAC
202 N N N IECC (R) - Changes approved to "acceptable to code official"
A 005 I
Seattle 202 N N N ISPSC - Leaves as code official and deletes authority having jurisdiction
A 005 II
Seattle 202 N N N IRC - Leaves as code official and deletes authority having jurisdiction
Impact: H=High, M=Moderate, L=Low, N=NonePosition: O=Oppose, S=Support, MO=Mild Opposition, MS=Mild Support, N = None
Action: A=Approve, D=Disapprove, AM=Approve as Modified, W=Withdrawn
Adm - ADMINISTRATIVEDe
sign
atio
n
Num
ber Proponent
Sect
ion
Impa
ct
PCA
Posi
tion
Committee Action
Publ
ic C
omm
ent Public
Comment
Fina
l Act
ion
Concept
A 006 I
Struct. Bldg. Components Assoc.
202 N N N IBC, IFGC, IMC, IPC, ISPSC - Adds "furnishing product certifications" to list of Approved Agency
A 006 II
Struct. Bldg. Components Assoc.
C202 N N N IECC (C) - Adds "furnishing product certifications" to list of Approved Agency
A 006 III
Struct. Bldg. Components Assoc.
R202 N N N IECC (R) - Adds "furnishing product certifications" to list of Approved Agency
A 006 IV
Struct. Bldg. Components Assoc.
202 N N N IRC - Adds "furnishing product certifications" to list of Approved Agency
A 007 I
Struct. Bldg. Components Assoc.
202 N N N IBC - Adds engineering law compliance to approved source
A 007 II
Struct. Bldg. Components Assoc.
202 N N N IRC - Approved source with engineering law compliance
A 008 I
BCAC, PMGCAC 202 N N N IEBC, IMC, IPC - defines structure as "used" in lieu of "occupied"
A 008 II
BCAC, PMGCAC 202 N N N Editorial
A 009 I
GBH, Shapiro, KH Scott
202 N N N IBC, IEBC, IFC - Clarifies definition regarding changes in occupancy
A 009 II
GBH, Shapiro, KH Scott
202 N N N IECC (C) - Clarifies definition regarding changes in occupancy
A 009 III
GBH, Shapiro, KH Scott
202 N N N IECC (R) - Clarifies definition regarding changes in occupancy
A 009 IV
GBH, Shapiro, KH Scott
202 N N N IRC - Clarifies definition regarding changes in occupancy
A 010 I
BCAC 202 N N N IBC, IEBC - Clarifies definition regarding changes in occupancy
A 010 I
BCAC 105.1, 110.1,
N N N IRC - Clarifies definition regarding changes in occupancy
A 011 I
Seattle 110.1 N N N IBC, IEBC - Clarifies definition regarding changes in occupancy
A 011 II
Seattle R110.1, R110.2
N N N IRC - Clarifies definition regarding changes in occupancy
A 012 I
BCAC, FCAC 202 N N N IEBC, IWUIC - Seems to unnecessarily adds "or duly authorized representative" to official
A 012 II
BCAC, FCAC 202 N N N IRC - Seems to unnecessarily adds "or duly authorized representative" to official
A 013 I
Seattle, FEMA 202 N N N IBC, IEBC - Adds existing building
A 013 II
Seattle, FEMA 202 N N N IRC - Adds existing building
A 014 I
BCAC, FCAC 202 N N N IBC, IFC - Clarifies historic building
A 014 II
BCAC, FCAC R202 N N N IRC - Clarifies historic building
A 015 I
BCAC PMGCAC, FCAC
202 N N N IBC,IFC, ISPSC, IZC - Re moves "under due legislative authority" from Jurisdiction
A 015 II
BCAC PMGCAC, FCAC
202 N N N IRC - Re moves "under due legislative authority" from Jurisdiction
A 016 I
BCAC, SEHPCAC, FCAC, PMGCAC
202 N N N IFC, IFGC, IMC, IMPC, ISPSC - Replaces "inspection agency" with "approved agency"
A 016 II
BCAC, SEHPCAC, FCAC, PMGCAC
C202 N N N IECC (C) - Replaces "inspection agency" with "approved agency"
A 016 III
BCAC, SEHPCAC, FCAC, PMGCAC
R202 N N N IECC (R) - Replaces "inspection agency" with "approved agency"
A 016 IV
BCAC, SEHPCAC, FCAC, PMGCAC
R202 N N N IRC - Replaces "inspection agency" with "approved agency"
A 017 I
NCSEA 202 N N N IEBC - Removes "load bearing element" because it is not used
A 017 II
NCSEA R202 N N N IRC - Removes "load bearing element" because it is not used
A 018 BCAC 202 N N N IZC - Refines definition of lot
A 019 I
BCAC 202 N N N ISPSC - Expands definition of "owner"
A 019 II
BCAC R202 N N N IRC - Expands definition of "owner"
A 020 BCAC 202 N N N IZC - Editorial on "person"
A 021 BCAC 202 L O D IPMC, IZC - street, alley or similar other parcel of land essentially unobstructed from the ground open
A 022 I
Shapiro 202 N N N IBC, IFC, IFGC, IMC, IPC, IPSDC, IZC - Clarifies design professional
A 022 II
Shapiro C202 N N N IECC (C) - Clarifies design professional
A 022 III
Shapiro R202 N N N IRC - Clarifies design professional
A 023 BCAC, PMGCAC 202 N N N IPC, IZC - Clarifies design professional
A 024 BCAC 202 N N N IEBC - Clarifies design professional
A 025 PMGCAC 202 N N N Clarifies "Repair"
A 026 I
WJE 202 N N N IBC, IEBC, ISPSC - Adds "Replacement" to "Repair"
A 026 II
WJE C202 N N N IECC (C) - Adds "Replacement" to "Repair"
A 026 III
WJE R202 N N N IECC (R) - Adds "Replacement" to "Repair"
A 026 IV
WJE R202 N N N IRC - Adds "Replacement" to "Repair"
A 027 I
NCSEA 202 N N N IBC, IEBC - Adds "correcting or restoring" to "repair"
A 027 II
NCSEA 202 N N N IBC, IEBC - Adds "correcting or restoring" to "roof repair"
A 028 BCAC, PMGCAC, FCAC
202 N N N IPC, IPMC, IWUIC, IZC - Removes "or portion thereof" from "structure"
A 029 I
Oregon BOA 202 N W N IBC, IFC - Clarifies "townhome"
A 029 II
Oregon BOA R202 N W N IRC - Clarifies "townhome"
A 030 BCAC [A]103 … N N N ICCPC - Editorials on design professionals, etc.
A 031 NAHB [A]101.1 N N N IEBC - Removes townhomes from IEBC
A 032 Shapiro [A]101.2 N N N IBC - Removes "multiple single family dwellings" leaving townhomes
A 033 Douglas Engineering
[A]101.2 N N N IBC - Adds "where not in compliance with this code"
A 034 I
Davidson [A]101.2 L O D IBC - Removes "detached" from "one and two-family.."
A 034 II
Davidson [A]R101.2 L O D IRC - Removes "detached" from "one and two-family.."
A 035 I
Shron, McLaurin [A]101.2 M O D IBC - Adds 4-story townhomes to exception
A 035 II
Shron, McLaurin C202 M O D IECC (C) - Adds 4-story townhomes to exception
A 035 III
Shron, McLaurin R202 M O D IECC (R) - Adds 4-story townhomes to exception
A 035 IV
Shron, McLaurin R101.2 M O D IRC - Adds 4-story townhomes to exception
A 036 CO Chapter ICC R101.2 L O D IRC - Clarifies sprinkler coverage of the code
A 037 Shapiro R101.2 N N N IRC - Adds care facilities for five or fewer to IRC
A 038 Davidson 310.5 N N N IBC, IRC - Removes "owner occupied" in front of "lodging"
A 039 EEI C101.2 N N N IECC - Excludes electric distribution facilities
A 040 BCAC [A]101.3 N N N IBC - from fire and other hazards attributed to the built environment , explosion or dangerous
A 041 I
Davidson [A]101.3 N N N IBC, ICCPC, IFC - during emergency operations and department of building safety personnel.
A 041 II
Davidson [A]101.3 N N N IRC - during emergency operations and department of building safety personnel.
A 042 I
NAHB C101.3 N N N IECC (C) - Adds "net energy" in front of "use"
A 042 II
NAHB R101.3 N N N IECC (R) - Adds "net energy" in front of "use"
A 043 I
EEI C101.3 N N N IECC (C) - Adds "production" to intent
A 043 I
EEI R101.3 N N N IECC (R) - Adds "production" to intent
A 044 Roetzel & Andress 101.3.1 H S A IBC - Life Safety. does not depend on a single fire protection
A 045 I
NAHB C101.3 H S A IECC (C) - deletes "over the useful life of each building."
A 045 II
NAHB R101.3 H S A IECC (R) - deletes "over the useful life of each building."
A 046 I
NAHB C102.1.1 H S A IECC (C) - Deletes: "The requirements identified as "mandatory" in Chapter 4 shall be met."
A 046 II
NAHB R102.1.1 H S A IECC (R) - Deletes: "The requirements identified as "mandatory" in Chapter 4 shall be met."
A 047 I
Conner C102.1.1 N N N IECC (C) - Clarifies material restrictions and adds accredited programs for design
A 047 II
Conner R102.1.1 N N N IECC (R) - Clarifies material restrictions and adds accredited programs for design
A 048 PMGCAC 102.2.1 N N N IFGC, IMC, IPC - Adds definition for existing buildings
A 049 GBH, Shapiro [A]102.3 N N N IFC - Requires compliance with IBC for change in occupancy
A 050 NAHB [A]102.5 N N N IFC - Removes "permits required"
A 051 I
Davidson [A]102.6.2 N N N IBC, IEBC, IWUIC - Replaces: "Buildings previously occupied" with "Existing structures"
A 051 II
Davidson R102.7 N N N IRC - Replaces: "Buildings previously occupied" with "Existing structures"
A 052 CO Chapter ICC R102.7 N N N IRC - Adds IEBC to existing building criteria
A 053 Davidson R102.7.1 N N N IRC - Exempts replacement doors and windows
A 054 I
EnergyLogic C103.1 N N N IECC (C) - Adds: "technical reports, compliance reports" after "Construction documents"
A 054 II
EnergyLogic R103.1 N N N IECC (R) - Adds: "technical reports, compliance reports" after "Construction documents"
A 055 I
Davidson [A]104.1 N N N IBC, IEBC, IFC, IFGC, IMC, IPC, IPSDC, IPMC, ISPSC, IWUIC - Adds: "Policies shall be in written form and
A 055 II
Davidson R104.1 N N N IRC - Adds: "Policies shall be in written form and be available to the public on request"
A 056 I
CO Chapter ICC C104 N N N IECC (C) - Clarifies inspection criteria "invalid in lieu of valid"
A 056 II
CO Chapter ICC R104 N N N IECC (C) - Clarifies inspection criteria "invalid in lieu of valid"
A 057 I
CO Chapter ICC C104 N N N IECC (C) - Deletes list of inspection criteria
A 057 II
CO Chapter ICC R104 N N N IECC (R) - Deletes list of inspection criteria
A 058 I
theGreenTeam [A] 105 N N N IEBC, IFC, IFGC, IMC, IPC, IPSDC, IPMC, ISPSC, IWUIC - Revises language on alternative design and methods
A 058 II
theGreenTeam C102 N N N IECC (C) - Revises language on alternative design and methods
A 058 III
theGreenTeam R102 N N N IECC (R) - Revises language on alternative design and methods
A 058 IV
theGreenTeam R104 N N N IRC - Revises language on alternative design and methods
A 059 I
theGreenTeam [A] 105 N N N IEBC, IFC, IFGC, IMC, IPC, IPSDC, IPMC, ISPSC, IWUIC - Adds "innovative" to alternative design and
A 059 II
theGreenTeam C102 N N N IECC (C) - Adds "innovative" to alternative design and methods
A 059 III
theGreenTeam R102 N N N IECC (R) - Adds "innovative" to alternative design and methods
A 059 IV
theGreenTeam R104 N N N IRC - Adds "innovative" to alternative design and methods
A 060 I
CO Chapter ICC [A] 105 N N N IEBC, IFC, IFGC, IMC, IPC, IPSDC, IPMC, ISPSC, IWUIC - Modifies approval of alternative design and
A 060 II
CO Chapter ICC C102 N N N IECC (C) - Modifies approval of alternative design and methods
A 060 III
CO Chapter ICC R102 N N N IECC (R) - Modifies approval of alternative design and methods
A 060 IV
CO Chapter ICC R104 N N N IRC - Modifies approval of alternative design and methods
A 061 I
Hoover Treated Wood
[A] 105 N N N IEBC, IFC, IFGC, IMC, IPC, IPSDC, IPMC, ISPSC, IWUIC - Adds: "Any such approval shall not have the effect of
A 061 II
Hoover Treated Wood
C102 N N N IECC (C) - Adds: "Any such approval shall not have the effect of waiving any requirement in this code
A 061 III
Hoover Treated Wood
R102 N N N IECC (R) - Adds: "Any such approval shall not have the effect of waiving any requirement in this code
A 061 IV
Hoover Treated Wood
R104 N N N IRC - Adds: "Any such approval shall not have the effect of waiving any requirement in this code
A 062 I
theGreenTeam [A] 105 N N N IEBC, IFC, IFGC, IMC, IPC, IPSDC, IPMC, ISPSC, IWUIC - Records for alternative design and methods
A 062 II
theGreenTeam C102 N N N IECC (C) - Records for alternative design and methods
A 062 III
theGreenTeam R102 N N N IECC (R) - Records for alternative design and methods
A 062 IV
theGreenTeam R104 N N N IRC - Records for alternative design and methods
A 063 I
Davidson [A]105 L O D IBC, IEBC, IWUIC - Excludes all detached structures, garage doors, from permits
A 063 II
Davidson R105 L O D IRC - Excludes all detached structures, garage doors from permits
A 064 I
Scott Douglas [A]105 N N N IBC - Reduces retaining wall exception from 48 to 42 inches
A 064 II
Scott Douglas R105 N N N IRC - Reduces retaining wall exception from 48 to 42 inches
A 065 I
Davidson [A]105 N N N IBC - Exempts swimming pools from permits
A 065 II
Davidson R105 N N N IRC - Exempts swimming pools from permits
A 066 I
ICC Tri-Chapter [A]105 N N N IBC, IEBC - clarifies swings as outdoor
A 066 II
ICC Tri-Chapter R105 N N N IRC - clarifies swings as outdoor
A 067 I
WABO [A]105 N N N IBC, IEBC - exempts photovoltaic for R3 and U
A 067 II
WABO R105 N N N IRC - exempts photovoltaic for R3 and U
A 068 BCAC R015 L S A IRC - removes garages from exemptions
A 069 I
Davidson [A]105 N N N IBC, IEBC, IFC - Removes items required for permits regarding repairs
A 069 II
Davidson R105 N N N IRC - Removes items required for permits regarding repairs
A 070 NCSEA [A] 105 N N N Removes "ordinary" from in front of repairs
A 071 NCSEA [A] 105 N N N Clarifies language for repairs
A 072 FEMA R105 N N N Editorial: "repair in lieu of "restoration"
A 073 I
Davidson [A]105 N N N IBC, IEBC, IFC, IFGC, IMC, IPC, IPSDC, ISPSC, IWUIC, IZC - Permit Expiration
A 073 II
Davidson R105 N N N IRC - permit expiration
A 074 NAHB R106.1.4 M MS AM IRC - Requires test reports for fire ratings [Modify for ACI/TMS 216.1]
A 075 Firestop Council [A]107 N N N IBC, IEBC, IFC - Maintaining fire resistance integrity
A 076 Firestop Council [A]107 N N N IBC, IEBC, IFC - Maintaining fire stop integrity
A 077 AWC [A]107 H S A X IBC, IEBC - protection of structural systems of balconies from moisture - Requires public comment
A 078 I
NCHH, LEHA [A]107.2 N N N IBC, IEBC - Lead paint repairs
A 078 II
NCHH, LEHA 106.1 N N N IRC - Lead paint repairs
A 079 LACFD 107.6 N N N Occupant count in assembly buildings
A 080 I
Pruitt 109 N N N IBC, IEBC, IFGC, IMC, IPC, IPMC, IPSDC, ISPSC, IWUIC - Clarifies language on permit fees
A 080 II
Pruitt C107 N N N IECC (C) - Clarifies language on permit fees
A 080 III
Pruitt R107 N N N IECC (R) - Clarifies language on permit fees
A 080 IV
Pruitt R108 N N N IRC - Clarifies language on permit fees
A 081 State of MI R109 N N N IRC - Adds onerous criteria for testing
A 082 I
Shapiro [A]110.1 N N N IBC, IEBC< IFC, IFGC, IMC, IPC, -IPSDC, ISPSC, IWUIC - Remains exposed until after inspection
A 082 II
Shapiro 104.1 N N N IECC (C) - Remains exposed until after inspection
A 082 III
Shapiro R104.1 N N N IECC (R) - Remains exposed until after inspection
A 083 BCAC [A]110.1 N N N IBC, IEBC< IFC, IFGC, IMC, IPC, -IPSDC, ISPSC - Removes accessible and retains exposed for
A 084 I
GBH [A]110.1 N N N IBC, IEBC< IFC, IFGC, IMC, IPC, -IPSDC, ISPSC, IWUIC - Accessible or exposed for inspection
A 084 II
GBH C104.1 N N N IECC (C) - Uses accessible or exposed until after inspection
A 084 III
GBH R104.1 N N N IECC (R) - Uses accessible or exposed until after inspection
A 085 II
NCHH, LEHA [A]110.1 N N N IBC, IEBC - Making records available
A 085 II
NCHH, LEHA R109.5 N N N IRC - Making records available
A 086 Davidson R110.3 L W D IRC - Removes requirement for sprinklers on certificate of occupancy
A 087 AWC 110.3.6 H S A X IBC, IEBC - Weather exposed balcony Would like to see "and the structural framing is designed to be
A 088 I
Nu Wool [A]110.6 N N N IBC, IEBC, IFC, IFGC, IMC, IPC, IPSDC, ISPSC, IWUIC - Requires listing section numbers in violations
A 088 II
Nu Wool R109.4 N N N IRC - Requires listing section numbers in violations
A 089 Davidson R111.3 N N N Clarifies utility service disconnect authorization
A 090 I
Davidson [A]112.1 N N N IBC, IEBC, IFGC, IMC, IPC, IPMC, IPSDC, ISPSC, IWUIC - Deletes language eon connection to utility services
A 090 II
Davidson R111.1 N N N IRC - Deletes language eon connection to utility services
A 091 I
Davidson [A]112.2 N N N IBC, IEBC, IFGC, IMC, IPC, IPMC, IPSDC, ISPSC, IWUIC - Deletes language on temporary connection to utility
A 091 II
Davidson R111.2 N N N IRC - Deletes language on temporary connection to utility services
A 092 Pruitt 116 N N N IBC, IEBC, IFC, IPMC - Adds unsafe to subsections under section title unsafe
A 093 I
England Training Chp 1 N N N IBC - New Appendix on Administration and Enforcement
A 093 II
England Training Chp 1 N N N IECC (C) - New Appendix on Administration and Enforcement
A 093 III
England Training Chp 1 N N N IECC (R) - New Appendix on Administration and Enforcement
A 093 IV
England Training Chp 1 N N N IRC - New Appendix on Administration and Enforcement
A 093 V
England Training Chp 1 N N N IFC - New Appendix on Administration and Enforcement
A 093 VI
England Training Chp 1 N N N IPC - New Appendix on Administration and Enforcement
A 093 VII
England Training Chp 1 N N N IMC - New Appendix on Administration and Enforcement
A 093 VIII
England Training Chp 1 N N N IPSDC - New Appendix on Administration and Enforcement
A 093 IX
England Training Chp 1 N N N IFGC - New Appendix on Administration and Enforcement
A 093 X
England Training Chp 1 N N N IPMC - New Appendix on Administration and Enforcement
A 093 XI
England Training Chp 1 N N N IWUIC - New Appendix on Administration and Enforcement
A 093 XII
England Training Chp 1 N N N IZC - New Appendix on Administration and Enforcement
A 093 XIII
England Training Chp 1 N N N ICCPC - New Appendix on Administration and Enforcement
A 093 XIV
England Training Chp 1 N N N ISPSC - New Appendix on Administration and Enforcement
A 093 XVI
England Training Chp 1 N N N IEBC - New Appendix on Administration and Enforcement
A 094 ICC Ref. Std. H S A Referenced standards update - includes ACI 332, TMS 402, 403, and 602
*** END OF SECTION Adm - ADMINISTRATION ***
Desi
red
Com
mitt
ee
Asse
mbl
y
Desi
red
Asse
mbl
y
Concept
S 001 AWC 1401 M O D Reduces effects on balconies - advantage wood
S 002 National Asphalt Roofing Assn
1503.1 L N N Roof coverings - rewording
S 003 ISNTA (Staples and Nails)
1503.1 L N N Roof coverings - rewording
S 004 SPRI 1503.3 L W D Relaxes fire and waterproofing rating of parapets
S 005 National Asphalt Roofing Assn
1503.5 L N N Roof replacement ventilation
S 006 AWC 1503.6 L N N Clarifies current code intent
S 007 AWC 1503.7 L N N Additional ventilation for wood structures - increases cost of wood frame
S 008 National Asphalt Roofing Assn
1504.1.1 L N N Wind uplift on asphalt shingles - testing and labeling requirements
S 009 Dow 1504.2.1.1 L W A Concrete and clay roof tile testing method - update to latest ASTM designation
S 010 SPRI 1504.3 L N N Reduces wind uplift for ‘non-ballasted’ roof coverings.
S 011 SPRI 1504.3 L N N Clarification on service vs. ultimate loads for design of non-ballasted roof coverings
S 012 SPRI 1504.3.1.1 L N N Non-ballasted roof coverings
S 013 SPRI 1504 L N N Vegetative roof systems
S 014 ISNTA (Staples and Nails)
1504 L N N Sloped metal roofing
IBS - STRUCTURALImpact: H=High, M=Moderate, L=Low, N=None
Position: O=Oppose, S=Support, MO=Mild Opposition, MS=Mild Support, N = NoneAction: A=Approve, D=Disapprove, AM=Approve as Modified, W=Withdrawn
Desi
gnat
ion
Num
ber Proponent
Sect
ion
Impa
ct
PCA
Posi
tion
Committee Action
Publ
ic C
omm
ent Public
Comment
Fina
l Act
ion
S 015 RCA 1504.5 M O D Edges of low-sloped roofs - reduces cost for bituminous systems
S 016 SPRI 1504 L N N Gutter attachment - increases cost of bituminous roofing systems - reference has a typo (GD1) (see
S 017 SPRI 1504.7 L N N Update to reference roof covering standard
S 018 National Asphalt Roofing Assn
1504.7 L N N Update to latest roof covering reference standards
S 019 SPRI 1504.4 M O D Increases areas where aggregate roof systems are not allowed (from hurricane to wind-borne)
S 020 National Asphalt Roofing Assn
1504.8 M O D Aggregate roof systems - is there an 'approved method' that is industry accepted?
S 021 BCAC 1504.8 M S A Aggregate roof systems - clarification that no aggregate in hurricane zones
S 022 BCAC 1504.9 M S A Disallow aggregate ballasted roof in 250mph wind zones on critical blds - concrete system +
S 023 UL 1504.9 L W A Hail damage to roof - concrete system plus
S 024 FEMA 1504.9 M S A Loads on gutters - plus to concrete systems (see also S16)
S 025 GBH 202 L N N Vegetative roof systems
S 026 NRCA 1506.1 L N N Clarification on approved roof
S 027 FEMA 1507.1.1 L N N Underlayment for roofing systems - achieves consistency with IRC
S 028 National Asphalt Roofing Assn
1507.2 L N N Updates roofing references and requires labeling
S 029 National Asphalt Roofing Assn
1507.2.5 L N N No effective changes - wording
S 030 NRCA 1507.2.5 L N N Updates ASTM reference for roofing
S 031 ISNTA (Staples and Nails)
1507.17.4. L N N Roof underlayment - high wind attachment
S 032 ISNTA (Staples and Nails)
1507.2.8 L N N Roof underlayment - high wind attachment
S 033 National Asphalt Roofing Assn
1507.2.8.2 L N N Re-wording to clarify code intent - roofing
S 034 National Asphalt Roofing Assn
1507.2.9 L N N Editorial - roofing
S 035 # Not Used
S 036 ISNTA (Staples and Nails)
1507.4.4 L N N Editorial - roofing
S 037 Cedar Shake and Shingle Bureau
1507.8 L W A increases cost of underlayment to reduce storm damage
S 038 NRCA 1507.8 L N N Clarifies intent - roofing
S 039 Cedar Shake and Shingle Bureau
1507.8 L N N Roofing and siding labeling requirements
S 040 American Wood Protection Assn
1507 L N N Wood shake and wood foundations - clarifies intent
S 041 National Asphalt Roofing Assn
1507 L N N Clarifies procedures - roofing
S 042 National Asphalt Roofing Assn
1507 L N N Clarifies procedures - roofing
S 043 National Asphalt Roofing Assn
1507 L N N Permits base sheet to be used on roofs
S 044 National Asphalt Roofing Assn
1507 L N N Adds roofing standard
S 045 NRCA 1507 L N N Aeletes acrylic coatngs for roofs
S 046 Roof Coating Manufacturers Assn
1507 L N N Liquid applied roof coating to match IRC
S 047 Dow 1507 L N N Minimum roof slope
S 048 Dow 1507 L N N Photovoltaic roof panels
S 049 SEIA 1507 L N N Photovoltaic roof panels
S 050 Seattle 1507 L N N Moves re-roofing from IBC to IEBC
S 051 Roof Coating Manufacturers Assn
1507 L N N Existing roofs
S 052 SPRI 1507 L N N Ballasted photovoltaic systems
S 053 Jennifer Goupil (self)
1507 L N N Revised definition of self restraining force 'T' - consistent with ASCE 7-16
S 054 SGH 1507 L N N Updates IBC wind to consistent with ASCE 7-16 - no change in hurricane zones - slight reduction
S 055 Ed Huston NCSEA 1602.1 L W A Clarifies "fire wall horizontal live load"
S 056 Jennifer Goupil (self)
1602.1 L W A Updates IBC wind nomenclature and criteria to be consistent with ASCE 7-16
S 057 Jennifer Goupil (self)
1603.1 L N N Updates IBC snow load nomenclature and criteria to be consistent with ASCE 7-16
S 058 S NV ICC Cahpter 1603.1 L N N Requires listing roof dead loads on drawings
S 059 Scott Douglas (self) 1603.1 L N N Topology factor Kzt wind load
S 060 SEAONY 1603.1 L N N List base shear
S 061 OR Earthquake Awareness
1603.1 L W D Risk category changed to occuapncy and use
S 062 NCSEA 1603.1 L N N Consistent with current practice of including heavy equipment loads
S 063 Jennifer Goupil (self)
1603.1 L N N Deflections - updates IBC to be consistent with ASCE 7-16
S 064 NCSEA 1604 L N N Clarification on serviceability wind load deflections - submitted by NCSEA – no effective change
S 065 Douglas Engineering
1604 L N N Clarifies definition of clear span
S 066 NCSEA 1604 L N N Clarifies that long-term deflections include creep
S 067 AWC 1604 L S A Serviceability deflections of wood system – submitted by AWC – no effective change as it
S 068 AAMA 1604 L N N Deflection limit of L/175 if supporting glass - consistent with current practice
S 069 AAMA 1604 L N N Deflection limit of L/175 if supporting glass - consistent with current practice
S 070 AISI 1604 L N N Latest standards for steel joists - will increase cost of steel joist construction
S 071 OR Earthquake Awareness
1604 L N N Risk category changed to occuapncy and use
S 072 SGH 1604 L N N Tsunami updates for category III IV - submitted by R. Hamburger and J. Goupil (self)
S 073 OR Earthquake Awareness
1604 L N N Risk category changed to occuapncy and use
S 074 SEIA 1604 L N N Photovoltaic panels
S 075 ICC Ad Hoc Healthcare
1604 L N N Terminology update and may reduce resilience for some healthcare facilities
S 076 BCAC 1604 L N N Clarification on storm shelter and overall occupancy
S 077 Jennifer Goupil (self)
1604 L N N Updates IBC to be consistent with ASCE 7-16
S 078 SGH 1605 L N N Moves load combinations to ASCE 7-16
S 079 SPRI 1605 L N N Adds non-ballasted roof load combination
S 080 SPRI 1605 L N N Adds non-ballasted roof load combination
S 081 SEAONY 1605 L W A Adds increased structural integrity and resilience requirements - should consider for ASCE 7 (not IBC)
S 082 Scott Douglas 1605 L N N Add a level of consistency with ASCE 7 for marquees, awnings and canopies
S 083 Michael Anthony 1607.1 L N N Laboratory loadings
S 084 Scott Douglas 1607 L N N Loading for first floor corridors for hospitals and libraries
S 085 Jennifer Goupil (self)
1607 L N N Aligns loads with ASCE 7
S 086 NCSEA 1607 L N N Aligns loads with ASCE 7
S 087 Seattle 1607 L N N Clarifies live load reductions
S 088 Jennifer Goupil (self)
1607 L N N Align with ASCE 7 by adding roofs to concentrated loads
S 089 BCAC 1607 L N N Clarifies loads on handrails and vehicle barriers
S 090 Charles Bajnai 1607 L N N Increases loads on guardrails
S 091 SEAONY L W A Adds vehicle impact load on columns in parking - slight benefit to concrete systems
S 092 SEAONY 1607 L N N Reduces areas where live load reduction can apply
S 093 Jennifer Goupil (self)
1607 L N N Vegetative roof systems
S 094 NRCA 1607 L N N Adds sun control and shading to awnings
S 095 SEIA 1607 L N N Editorial for photovoltaic systems
S 096 SEIA 1607 L N N Reduces live load between photovoltaic systems
S 097 Huston 1607 L N N Reduces live load between photovoltaic systems
S 098 Jennifer Goupil (self)
1607 L N N Reduces live load between photovoltaic systems
S 099 SEIA 1607 L N N Design for self-standing photovoltaics
S 100 AWC 1607 M O D Oversimplifies design of fire walls - oppose as the criteria does not require gravity loads to be
S 101 Ali Fattah 1607 M S A Require gravity loads to be concurrent with lateral fire loads - slight advantage to concrete systems
S 102 SGH 1607 L W A Loads per ASCE 7-16
S 103 Jennifer Goupil (self)
1607 L W A Loads per ASCE 7-16
S 104 NCSEA 1609 L W A Wind loads on storm shelters
S 105 Metal Buildng Manufacturers Assn
1609 L N N Wind loads on roof components
S 106 NCSEA 1609 H W A Increases minimum thickness of wood panel for 'missile test' - advantage cement systems
S 107 SPRI 1609 L N N Non-ballasted roof coverings
S 108 SGH 1609 L N N Deletes alternate wind load procedure
S 109 NCSEA 1609 L W A Increases wind loads on low-rise roofs - advantage cement systems
S 110 Jennifer Goupil (self)
1609 L W A Aligns rain loads with ASCE 7-16
S 111 SGH 1609 L W A Aligns rain loads with ASCE 7-16
S 112 OR Earthquake Awareness
1613.3 L W D Deletes sesimic site coefficient
S 113 OR Earthquake Awareness
1613.3 L W D Deletes seismic design category
S 114 Jennifer Goupil (self)
1613.3 L N N Site class and coefficients aligned with ASCE 7-16
S 115 SGH 1613.3 L N N Site class and coefficients aligned with ASCE 7-16
S 116 OR Earthquake Awareness
1613.3 L W D Seismic terminology
S 117 KY Geological Survey
1613.3 L N N Updates sesimic maps for ground motion response accelerations of 0.2s and 1.0s in the central US
S 118 OR Earthquake Awareness
1613.3 L W D Trying to bring back the old UBC “Seismic Zones”
S 119 WJE 1613.3 L N N Coordination with ASCE 7-16 load maps
S 120 OR Earthquake Awareness
1613.3 L W D Trying to bring back the old UBC “Seismic Zones”
S 121 OR Earthquake Awareness
1613.3 L W D Trying to bring back the old UBC “Seismic Zones”
S 122 OR Earthquake Awareness
1613.3 L W D Trying to bring back the old UBC “Seismic Zones”
S 123 SEAONC and NCSEA 1613.3 L W A Adds additional rigor to the evaluation reports - plus for concrete, neg for new materials
S 124 SEIA 1613.3 L N N Ballasted photovoltaic systems
S 125 OR Earthquake Awareness
1615 L N N The concept of increasing the resiliency of high-rise buildings is admirable; however, assigning high-rise
S 126 NCSEA 1615 L W A Editorial - avoids any misinterpretation for design of frame versus bearing
S 127 SEAONY 1616 L N N Adds requirements for 'structural peer review' of substantial projects - challenge that "structural peer
S 128 S NV ICC Cahpter 1704 L N N Requires registered professional to provide structural observations for substantial projects -
S 129 AISI 1704 L N N Adopts current specifications for cold formed steel - may slightly increase the cost of cold formed steel
S 130 SEIA (self) 1704 L N N Editorial - special inspection
S 131 AISI 1704 L N N Special inspections of fabricated items - editorial
S 132 AISI 1704 L N N Special inspections of 'erected items'
S 133 NCSEA 1704 L S A Adds special inspections for special structures (cat IV, high-rise, occupancy > 1000, or when requested) -
S 134 NCSEA 1704 L S A Updates wind speed that triggers special inspections from ASD to ULT (consistent with
S 135 AISI 1705 L N N Special inspections in steel construction - meant to be editorial in nature
S 136 SKG 1705.3 H S A Special inspections for welding with rebar - intends to reverse a technical change caused by an
S 137 NCSEA 1705.11.1 H S A Adds special inspections for wood construction - wood previously did not require much in special
S 138 NCSEA 1705.5.2 H S A Adds special inspection for wood trusses - on par with other construction materials
S 139 SEIA 1705.5.2 L N N Clarifies special inspection for soils and foundations
S 140 SEIA 1705.5.2 L N N exempts from special inspections foundations for photovoltaic systems without occupied space below
S 141 SEIA 1705.5.2 L N N Inspectors inspect, they do not test - corrects wording
S 142 SEIA 1705.5.2 L N N Adds special inspections for auger cast piles
S 143 SEIA 1705.5.2 L N N Adds special inspections for micro piles
S 144 NCSEA 1705.5.2 L N N Updates wind load references to ultimate from ASD for special inspections - submitted by NCSEA
S 145 Randy Shackleford 1705.5.2 L W A Increases special inspections for wood shear walls - slight advantage cement based systems
S 146 AISI 1705.12 L N N Structural steel inspections - proposal is intended to only clarify existing provisions
S 147 BSSC 1705.12 L W A Seismic - special inspections for items such as pipes and ducts to reduce damage to such items as fire
S 148 SEAONY 1705.18 L N N Adds special inspections for wall panels, curtain walls and veneers in tall buildings - increases cost of
S 149 WJE 1708 L N N In-situ testing
S 150 WDMA 1708 L N N Loads on windows and doors
S 151 IBHS 1709.5 L N N Loads on windows and doors
S 152 National Asphalt Roofing Assn
1709 L N N Adds plastic glazing requirements for fenestrations
S 153 FEMA 1709 L N N Loads on windows and doors
S 154 FEMA 1709 L N N Wind-born debris protections - proposal has problems - needs to clarify 'allowable stress only'
S 155 National Asphalt Roofing Assn
1709 L N N Adds plastic glazing requirements for skylights
S 156 MA Board of Building
1801 L N N Adds alternate foundation types (non-typical)
S 157 GeoCoalition 1803 L N N Adds compressible soils
S 158 GeoCoalition 1803 L N N Updates geotechnical engineering study requirements
S 159 GeoCoalition 1803 L N N Clarifies the responsibilities of the registered design professional's representative for soils and
S 160 GeoCoalition 1803 L N N Clarifies collapsible soils and expansive soils
S 161 GeoCoalition 1803 L N N Clarifies effects on earthwork and foundation construction and groundwater
S 162 GeoCoalition 1803 L N N Editorial - borings for foundations on rock
S 163 Huston 1803.5.7 L N N Clarifies the need for a preconstruction assessment for excavation near foundation
S 164 GeoCoalition 1803 L N N Editorial for engineerng studies in seismic areas
S 165 GeoCoalition 1803 L N N Clarifies the geotechnical engineering study requirements
S 166 Jennifer Goupil (self)
1803 L W A Updates references to ASCE 7-16 foundations in seismic
S 167 NCSEA 1804 L N N Excavations shall not reduce vertical or lateral support for adjacent foundations
S 168 GeoCoalition 1804 L N N Excavations shall not reduce vertical or lateral support for adjacent foundations
S 169 NCSEA 1804 L N N Adds underpinning as a permanent element
S 170 GeoCoalition 1804 L N N Add underpinning system to be designed by registered design professional
S 171 GeoCoalition 1804 L N N Backfilling against foundation walls
S 172 GeoCoalition 1804 L N N Adds underpinning monitoring
S 173 GeoCoalition 1804 L N N Adds foundation walls to site grading plans
S 174 Eirene Oliphant 1804 L N N Adds wording to include cross slope for accessibility in terms of site grading
S 175 GeoCoalition 1804 L N N Adds inclusion of a "registered design professional" to demonstrate that flood hazard area
S 176 S NV ICC Cahpter 1804 L N N Clarifies soil compaction requirements
S 177 MA Department of Public Safety
1805 L N N Option to remove foundation drain when determined not be necessary by a registered design
S 178 MA Department of Public Safety
1806 L N N Adds limitations on the impact on groundwater levels
S 179 GeoCoalition 1806 L N N Editorial for 'presumptive soil load-bearing capacity'
S 180 GeoCoalition 1806 L W A Adds reference to settlement limitations
S 181 MA Department of Public Safety
1806 L N N Adds reference to table for isolated pole lateral bearing pressure
S 182 GeoCoalition 1807 L W D Reduces the range of prescriptive concrete and masonry foundation walls design (adds exemption
S 183 GeoCoalition 1807 L N N Requires a 'registered design professional' to design a retaining wall
S 184 GeoCoalition 1807 L N N Clarifies design of retaining walls - textbook material
S 185 Swanson Associates Engineering
1807 L N N Clarifies design of retaining walls with keyway - textbook material
S 186 GeoCoalition 1807 L N N Adds retaining walls to be designed for seismic in SDC D, E or F - could be hard to implement as SDC is
S 187 San Diego 1807 L N N Editorial - adding wind into overturning
S 188 MA Department of Public Safety
1807 L N N Clarifies the design of retaining walls
S 189 S NV ICC Cahpter 1807 L N N Adds wind loads to retaining walls
S 190 GeoCoalition 1807 L N N adds that overall stability of retaining structures be evaluated by the 'registered design professional'
S 191 GeoCoalition 1807 M S A Adds that retaining walls built-up of discrete elements (such as mortar less masonry) shall have a
S 192 GeoCoalition 1807 L N N Requires retaining walls to be design to consider water pressures, unless a drainage system is
S 193 MA Department of Public Safety
1808 L N N Explicitly adds 'adequate load bearing capacity while limiting settlement, heave and lateral
S 194 SGH 1808 L W A Updates pointers in IBC to ASCE 7-16
S 195 S NV ICC Cahpter 1808 L N N Clarifies requirements if an existing slab on ground is used to resist loads
S 196 ICC Region III 1808 L N N Clarifies the 'exterior landings' shall be protected from frost
S 197 GeoCoalition 1810.1.2 L N N Defines that 'use of existing deep foundation elements' shall be deemed suitable for reuse by the
S 198 GeoCoalition 1810.1.2 L N N Clarification of terminology for lateral support of deep foundations
S 199 GeoCoalition 1810.1.2 L N N Defines that the 'stability of deep foundation elements' shall be deemed by the 'registered design
S 200 GeoCoalition 1810.1.2 L N N Defines the 'registered design professional' to determine group effects of foundations
S 201 GeoCoalition 1810.1.2 L N N Settlement of deep foundations shall be estimated based on 'generally accepted' methods of analysis
S 202 GeoCoalition 1810.1.2 L N N Design of deep R/C foundations – Clarifies the design parameters and references ACI 318 for the
S 203 M. Snider (self) 1810.1.2 L N N Adds definition and inspection requirements for ‘segmented precast piles’ – previously not discussed
S 204 GeoCoalition 1810.1.2 L N N Clarifies the design methods for structural steel deep foundation elements
S 205 GeoCoalition 1810.1.2 L N N Adds definition ‘combined pile raft’ foundation (raft and piles share loading) – previously not discussed in
S 206 GeoCoalition 1810.1.2 L N N Allowable stresses on deep foundations – clarifies axial load
S 207 GeoCoalition 1810.1.2 L N N Editorial - allowable loads
S 208 GeoCoalition 1810.1.2 L N N Changes foundation load capacities are determined (previous IBC allowed analysis or load test –
S 209 GeoCoalition 1810.1.2 L N N Permits the load test for deep foundations to be waived by the registered design professional
S 210 GeoCoalition 1810.1.2 L N N Updates the driving criteria for driven deep foundations to current practice
S 211 GeoCoalition 1810.1.2 L N N Clarifies wording for load testing of foundations and updates reference standards
S 212 GeoCoalition 1810.1.2 L N N Keeps the design professional in the loop for the other optional load test evaluation
S 213 GeoCoalition 1810.1.2 L N N Terminology for piles (skin friction and bearing vs. shaft and end-bearing terms) – terms vary by region.
S 214 GeoCoalition 1810.1.2 L N N Editorial - foundation uplift
S 215 GeoCoalition 1810.1.2 L N N Editorial - foundation uplift
S 216 GeoCoalition 1810.1.2 L N N Editorial - bearing capacity
S 217 GeoCoalition 1810.1.2 L N N Adds the design professional to the 'bent deep foundations'
S 218 GeoCoalition 1810.1.2 L N N Rewords and reorganizes the section on Helical piles
S 219 GeoCoalition 1810.1.2 L N N Adds the design professional to the 'allowable lateral load' on foundations
S 220 GeoCoalition 1810.1.2 L N N Adds the design professional to 'subsiding soils' and updates terminology
S 221 GeoCoalition 1810.1.2 L N N Adds 'grouted-in-place' deep foundation elements to items with a permanent casing requirements -
S 222 GeoCoalition 1810.1.2 L N N Adds 'grouted-in-place' deep foundation elements to items with a permanent uncasied requirements -
S 223 GeoCoalition 1810.1.2 L N N Changes micro piles from 'an outside diameter' to 'a nominal diameter of 12" or less (consistent with
S 224 GeoCoalition 1810.1.2 L N N Adds reference to AWS D1-1 for fully welded steel piles fabricated from plates
S 225 GeoCoalition 1810.1.2 L N N Adds design professional to steel pipes and tubes foundations
S 226 GeoCoalition 1810.1.2 L N N Updates the splice requirements and makes the design professional responsible for the design of the
S 227 SKG 1810.3.8 M S A Updates seismic design of precast piles to latest approach - increases confinement requirements -
S 228 Pieresearch 1810.3.8 L N N Updates requirements for placement of reinforcement in deep foundations
S 229 GeoCoalition 1810.3.8 L N N Changes the term 'socketed drilled shaft' to 'caisson pile'
S 230 GeoCoalition 1810.3.8 L N N Clarifies the term 'driven concrete piles'
S 231 GeoCoalition 1810.3.8 L N N Changes the section title from 'casing' to 'shafts in unstable soils' and adds alternate methods
S 232 GeoCoalition 1810.3.8 L N N Delineates who is responsible for consideration of heave and the determination of how much heave is
S 233 GeoCoalition 1810.3.8 L N N "Defective timber piles" - terminology
S 234 GeoCoalition 1810.3.8 L N N Micro pile installation requirements (adds design professional)
S 235 GeoCoalition 1810.3.8 L N N Helical piles - adds design professional and clarifies the Code
S 236 GeoCoalition 1810.3.8 L N N Permits integrity testing of deep foundation elements where required by the design professional -
S 237 GeoCoalition 1810.3.8 L N N Changes 'driven' to 'advanced' for deep foundation element tips during preexcavation evaluation
S 238 GeoCoalition 1810.3.8 L N N Updates 'vibratory driving' requirements
S 239 GeoCoalition 1810 L N N Updates 'heaved element' deep foundation requirements
S 240 GeoCoalition 1802 L W A Adds specifically 'augered cast-in-place' (ACIP) elements to the IBC
S 241 GeoCoalition 1804 L N N Adds 'temporary earth retention systems' to the IBC
S 242 SKG 1613 H S A Adds modern seismic precast diaphragm design procedures to the code by reference to ASCE 7-16
S 243 TMS 202 L W A Updates ASTM references for Autoclaved Aerated Concrete (AAC)
S 244 MACS 2101 H S A Updates TMS references for masonry
S 245 MACS 2103.1 H S A Updates ASTM references for masonry
S 246 MACS 2103 L W A Clarification of the historical interpretation of masonry pilasters
S 247 NCSEA 2107 L N N Reduces lap splice lengths from TMS 402-11
S 248 MACS 2109 L W A Deletes maximum bar size in masonry from the IBC which is covered under the reference standard
S 249 MACS 2109 L W A Restores empirical design for adobe construction while retaining the existing dry-stack provisions -
S 250 MACS 2109.3.4 L W A Removes an IBC modification to the TMS standard on empirical wind
S 251 Loescher Meachem Architects
2109 L O D Adds adobe soil mortar in additon to mortars permitted for masonry
S 252 AISI 2203 L N N Updates the IBC to the latest industry standards for cold-formed steel
S 253 Jennifer Goupil (self)
2208 L N N Updates the IBC to the ASCE 19 provisions for steel cables
S 254 Simpson Strong Tie 2211.6 L N N Updates the IBC to the latest AISI S914-15 for cold formed steel
S 255 Rack Manufacturers Institute
2211 L N N Updates the IBC cantilevered storage racks with the ASCE 7 standard
S 256 NYS CBSC 2303.1 M O D Proposal deletes the requirement for a 'grade mark' or 'certificate of inspection by a lumber grading or
S 257 AWC 2303 L N N Adds clarification on the design values for treated structural composite lumber
S 258 AWC 2303 L N N Clarifies the standards for hardboard siding
S 259 AWC 2303 L N N Modifies the adjustment factors for treated wood per the current standards
S 260 GBH 2303 L W D Adds reference to the ASTM E2768-11 standard test method for extended duration surface burning
S 261 2303 # Not in file from ICC
S 262 Hoover Treated Wood Products
2303 L N N Clarifies 'impregnated with chemicals' for treated wood
S 263 2303 # Not in file from ICC
S 264 GBH 2303 H O D Eliminate testing for fire retardant treaded wood products that have been treated by other than a
S 265 Hoover Treated Wood Products
2303 M S A Increases the labeling requirements for wood products
S 266 Stephen Kerr (self) (self)
2303 L N N Clarify the requirements for wood truss design drawings
S 267 NCSEA 2303 L W A Clarifies that permanent individual wood truss member restraint / bracing must be designed and
S 268 NCSEA 2303 L N N Harmonizes TP 1-2014 with IBC section 2303.4 for wood trusses
S 269 Douglas Engineering
2303 L W A Increases labeling requirements for nails and staples
S 270 NCSEA 2303 L W A Increases the requirements for staples not in conformance with ISANA ESR-1539 - submitted by
S 271 NCSEA 2304 L N N Removes redundant language on roof sheathing
S 272 AWC 2304 L N N Changes minimum nail size for roof sheathing to match IRC and adds roof sheathing ring shank as an
S 273 AWC 2304 L N N Editorial, adds consistency with recognized sizes in the IRC on roof sheathing
S 274 NCSEA 2304 L W A Specifies the type of stainless steel (300 series) for FRTW - prohibits lesser grade stainless steels -
S 275 NCSEA 2304 L W A Specifies where stainless steel staples are required for FRTW - increases cost of wood construction
S 276 AWC 2304 L N N Adds pointer for lumber decking under 'heavy timber construction'
S 277 EWA 2304 L W D Permits 'preservative treatments' which are not water-borne - new item
S 278 Simpson Strong Tie 2304 L W D For wood in contact with concrete footing - proposal wants to revert back to closer to 2012 IBC
S 279 AWC 2304 L N N adds the requirement for positive drainage for permeable floors and roofs
S 280 NCSEA 2304 L N N Editorial and clarification on 'exterior glue'
S 281 AWC 2304 L W D Adds mechanically laminated decking - could compete with concrete
S 282 Stephen Kerr (self) 2306 L N N Modifies wood diaphragm deflection for stapled vs. nailed conditions (coordination change between
S 283 Stephen Kerr (self) 2306 L N N Editorial on table for calculating wood deflections
S 284 Stephen Kerr (self) 2306 L N N Editorial on calculating wood deflections
S 285 Stephen Kerr (self) 2306 L N N Clarifies items in table wood shear values
S 286 AWC 2306 L N N Incorporates footnotes into shear value table
S 287 BCAC 2306 L N N Clarifies that the concrete slab-on-ground for risk category I and II may support a greater live load than
S 288 AWC 2306 L N N Completely updates the header and girder span tables to update from Southern Pine No. 1 to
S 289 AWC 2306 L N N Completely updates the header and girder span tables to update from Southern Pine No. 1 to
S 290 AWC 2306 L N N Adds footnote to wall bracing requirements table to add transparency to the basis of the table
S 291 BCAC 2308 L N N Fix errors introduced in IBC 2012 relative to attachments (anchor bolt placement)
S 292 AWC 2308 L W D Adds alternate prescriptive header design consistent with the IRC - just because something is
S 293 SBCA 2308 L N N Non-technical - clarifies design of uplift and bracing
S 294 Seattle 1406 L N N Proposes to change the term 'guardrail' to 'guard'
S 295 WABO 2407 L N N Clarifies code requirements for glass panels
S 296 Seattle 2407 L N N Editorial - glazing factor of safety
S 297 Glazing Industry Code Committee
2407 L N N Adds ASTM E2353-14 testing for glazing
S 298 Kellen Co. 2506 L N N Updates ASTM standards for gypsum wallboard
S 299 AISI 2506 L N N Updates to latest cold formed steel standards for gypsum board backup
S 300 Kellen Co. 2506 L N N Increases product selection options for gypsum wallboard
S 301 Foam Sheathing 2510 L W D Adds additional options for water-resistive barriers over wood-based sheathing
S 302 Foam Sheathing 2510 L N N Provides limitations that may affect some water resistive barrier choices
S 303 Building Professionals
2610.6 L N N Adds ASTM E2925 reference for water resistive barriers
S 304 Building Professionals
2510 L N N Adds ASTM E2925 reference for water resistive barriers
S 305 Dupont 2510 L N N Reorganizes the section water resistive barriers
S 306 FEMA G101 L W A Relative to flood references, the 'building official' is replaced by the ' floodplain administrator' as per the
S 307 FEMA G101 L W A Relative to flood, editorial - submitted by FEMA
S 308 FEMA G101 L W A Requires submission of new technical data for flood hazard areas as per the National Food Insurance
S 309 FEMA G101 L W A Requires records be keep for flood hazard areas as per the National Food Insurance Program -
S 310 FEMA G101 L W A Editorial - Recreational vehicles for flood
S 311 GBH H106 L N N Internally illuminated signs
S 312 GBH H107 L N N Requirements for light transmitting materials
S 313 OR Earthquake Awareness
L101 L N N Changes the requirements of buildings with earthquake recording instrumentation from based
S 314 OR Earthquake Awareness
M101 L W D Changes the tsunami approach - drops reference to FEMA P646 - change not required (see also S316)
S 315 FEMA M101 L W A FEMA P646 has been superseded by ASCE 7-2016 tsunami
S 316 OR Earthquake Awareness
1603 L W D Removes the requirement to provide, on the construction documents, the SDC for light-frame
S 317 OR Earthquake Awareness
1613 L W D Changes the approach to seismic design
S 318 OR Earthquake Awareness
1613 L W D Changes the approach to seismic design
*** END OF SECTION IBC - STRUCTURAL ***
Desi
red
Com
mitt
ee
Asse
mbl
y
Desi
red
Asse
mbl
y
CE 001 MathisC202, R202
L W N Clarifies definition for air barriers. Prefer CE003
CE 002 Energy LogicC202, R202
L W N Clarifies definition of air barrier. Prefer CE003
CE 003 DupontC202, R202
L S AClarifies definition for air barriers and deletes definition for continuous air barrier.
CE 004 Energy LogicC202, R202
N N NRevises definition of building thermal envelope expanding to any building element between conditioned and unconditioned or outside spaces.
CE 005 ARESC202, R202
N N N New definition for cavity insulation
CE 006 EEI C202 N N NClarifies definition of (COP) Coefficient of Performance (cooling)
CE 007 Bellevue, WAC202, R202
N W NAdds changes for design of portions of buildings: commercial and residential in mixed occupancy buildings
CE 008 Energy LogicC202, R202
N N NNew definition for Compliance Report supports section C407
CE 009 EEI C202 N N NChange to the definition for computer room with makes it consistent with ASHRAE 90.1.
IECC-COMMERCIALImpact: H=High, M=Moderate, L=Low, N=None
Position: O=Oppose, S=Support, MO=Mild Opposition, MS=Mild Support, N = NoneAction: A=Approve, D=Disapprove, AM=Approve as Modified, W=Withdrawn
Desi
gnat
ion
Num
ber Proponent
Sect
ion
Impa
ct
PCA
Posi
tion Committee
Publ
ic
Com
men
t
Public
Fina
l Act
ion
Concept
CE 010MacroAir/Air Movement Control Assn
C202, C303.2.2 new,
N N NNew definitions for remittance and interior radiation control coating (IRCC)
CE 011 SEHPCACC202, R202
N N NEditorial - formats the Fenestration, Skylights and Vertical Fenestration definitions
CE 012 EEI C202 N N N Clarifies current definition of heat trap
CE 013 CO Chapter ICCC202, R202
N N N New definition for insulated siding
CE 014 EEIC202, R202
N N N Modifies definition for low voltage lighting
CE 015 EEI C202 N N NDefinition for motor horsepower rating is changed to address output power rating
CE 016 EEI C202 N N NDefinition onsite renewable energy, adds biogas to the current definition
CE 017 EEI C202 N N NDefinition for screw lamp holders is modified to address LED general service lamps.
CE 018 SEIAC202, R202
N N NClarifies current definitions for onsite renewable energy and renewable energy
CE 019New Building Institute
C202 N N NNew definition for on-site renewable energy system and modification of renewable energy source
CE 020 IALD C202 N N N Deletes the definition for screw lamp holders
CE 021 ASHRAEC301.1 tables and map;
M S ADeletes climate zone figure and tables in favor of a new reference to ASHRAE 169-2013
CE 022 ConnerC301.1 tables
N N NAdds tropical climate zone to the C301,1 Climate Zone Table
CE 023 DOEC409 new; R407 new
H S AAdds new compliance option for conditioned passive buildings.
CE 024 Energy LogicC303.1.2, R303.1.2
N N NNew requirement for insulation certificate or marks
CE 025MacroAir/Air Movement Control Assn
C202, C303.1.1, R202,
N N NNew definition for reflective insulation which supports thermal envelope insulation materials
CE 026 NRCAC303.1.1, R303.1.1
N N N Adds new exception that requires insulation labeling for insulation above decks
CE 027 NRCAC202, C303.1.1, R202,
N N N New definition for certificate of compliance
CE 028Reflective Insulation Manufacturers
C202, C303.1.5 new;
N N NNew definitions for emittance and radiant barriers.
CE 029 SEHPCAC C303.1.3 N N NChanges to both garage doors and rolling doors language in this section
CE 030 SEHPCAC C303.1.3 N N NRevises table headings to distinguish opaque doors from glazed windows, doors and skylights
CE 031Energy Efficient Code Coalition
C303.1.3, R303.1.3
N N N Fenestration certification
CE 032 AAMA C303.1.3 N N N Fenestration rating and labeling
CE 033 ZimmerC303.1.3, R303.1.3 others
N N N Products from outside USA
CE 034New Building Institute
C303.3, C408.1.1
N N N Maintenance documents
CE 035 connerC401.2 new
N N N Onsite renewables
CE 036 IALDC401.2, C408 & related
N N N Commissioning
CE 037 NIBS C409 new L W A Adds outcome based compliance
CE 038 SEHPCAC C401.2 L S A Editorial - reorganization
CE 039 Conner C401.2 M O DRetains 2015 IECC climate zones in lieu of ASHRAE updated maps
CE 040 ASHRAE C401.2 N N NNew definition for Information Technology Equipment and a new reference to ASHRAE 90.4 as a compliance option
CE 041 ASHRAEC104.5, C408 and related
N N N Commissioning and inspections
CE 042 FosterC401.2 (related to C407)
L W A Relaxes building cost threshold from 85% to 95%
CE 043Energy Efficient Code Coalition
C401.2; C406.1
L W DMore stringent performance path by 5 percent 85 to 80.
CE 044Gas Technology Institute
C401.2 L W A Adds ASHRAE 90.1 as a compliance option
CE 045Northwest Energy Codes Group
C407 L W AThree changes to this section direct user to performance approaches in ASHRAE 90.1 evaluation
CE 046 EEIC401.2 (related C407
L W AMakes energy cost equal to reference design in lieu of 85% - like the best
CE 047 SEHPCAC C401.2.1 N N N Editorial - replacement fenestration
CE 048Glazing Industry Code Committee
C401.2.1, C402.4.3.4
N N N Replacement fenestration
CE 049 Crandell C402.1 L W NRequires vapor retarder for all walls - okay is vapor barrier exceptions for concrete remain.
CE 050 EEI C402.1.1 N N NExempts small buildings for electrical distribution from envelope criteria
CE 051 SEHPCAC C402.1.2 N N N Adds criteria for greenhouses
CE 052 ASHRAETC402.1.3 and others
L W AUpdates climate zones and includes climate zone 0 ref. ASHRAE 169-2013
CE 053 ASHRAEC202, C402.1.3 etc
N N NEditorial definitions and reorganization of swinging doors in envelope tables
CE 054Energy Efficient Code Coalition
Table C402.1.3; Table
L W N Envelope upgrades and ref. ASHRAE 90.1
CE 055 CO Chapter ICCC402.1.3; C402.1.4 C402.4.4
N N NEditorial reorganization - doors and walls making it easier to find thermal envelope components
CE 056 CO Chapter ICCC402.1.3,C402.1.4, C402.2.4
N N N Editorial - Moves below grade walls to new section
CE 057Coalition for Fair Energy Codes
Table C402.1.3; Table
M W D Appears to reduce R value requirements for wood walls.
CE 058Coalition for Fair Energy Codes
Table C402.1.3; Table
M W D Appears to reduce R value requirements for wood walls.
CE 059Coalition for Fair Energy Codes
Table C402.1.3; Table
M W D Appears to reduce R value requirements for wood walls.
CE 060 SEHPCAC N N N Garage door U-values
CE 061 SEHPCAC L S ACorrects R values in climate zones 7 & 8 for heated slab on grade floor insulation ASHRAE 90.1
CE 062Foam Sheathing Committee of ACC
Table C402.1.3; Table
N N NChange increases insulation requirements for heated slabs on grade
CE 063Pacific Insulation Products
Table C402.1.3
N N NUpdates metal building wall criteria to current ASHRAE 90.1
CE 064 ASHRAETable C402.1.3, C402.1.4,
L S AUpdates climate zones to include climate zone 0; wall reflectance ASHRAE 169-2013
CE 065 OR Building DeptC402.1.3; R402.2.6
N N N Editorial - "meet" to "comply with"
CE 066Chicago Roofing Contractors Assn
Table C402.1.3,
L W N Adds new standard how to test R-value
CE 067 SFATable C402.1.3
L W N Increases flexibility for frame wall design
CE 068 SEHPCACTable C402.1.3
N N N Editorial - clarifies foot notes
CE 069 SEHPCACTable C402.1.4
L S A Corrects Mass Wall Values in Climate Zone 6
CE 070 MBMATable C402.1.4
L W N Metal building walls
CE 071 MACSTable C402.1.4
M S ACorrects U factor requirements for mass walls and mass floors.
CE 072Glazing Industry Code Committee
C402.1.5 and others
L S N Fenestrations - Opening limitations
CE 073Northwest Energy Codes Group
C402.1.5; table C402.1.5
L W N Revises envelope criteria for fenestrations
CE 074 CO Chapter ICCC402.2.1; C303.2.2
N N N Editorial - Relocates continuous insulation
CE 075Plastic Glazing of ACC
C402.2.2 N N NRoof - average weighted area in lieu of min. insulation thickness
CE 076 PIMA C402.2.2 N N N Roof - requires vapor retarder
CE 077 Thermal DesignC402.2.2, C402.2.3
N N N Revises language for envelope R and U values
CE 078Center for Environmental Innovation in
C402.2.2 N N N Roof - layers of continuous insulation
CE 079 NRCAC402.2.2, C402.2.1new
N N N Roofs - exceptions
CE 080 NRCA C402.2.2 N N N Roof - exceptions
CE 081 NRCA C402.2.2 N N N Roofs - clarification
CE 082 NRCAC402.2.2, C402.2.2.1 new
N N N Skylights
CE 083 MACS C402.3 H S AWall R-values - fixes above grade walls R values and U factors
CE 084 SEHPCAC C402.1.3 N W NImproves mass wall / mass floor definitions moved from footnotes and to body text.
CE 085UT Chapter of ICC
C402.2.5 N N NAdds slab on grade perimeter insulation to mandatory criteria
CE 086 UrsenbachC402.2.5.1 new; R402.2.10
N N N Radiant heated slab on grade
CE 087Foam Sheathing Committee of ACC
C402.2.7 new; R402.2.14
M O DAirspaces shall be unventilated - Vented and weeped masonry walls have no significant reduction in R-value - proponent to show test
CE 088 GBHC202, C402.3
N N N Vegetative roof
CE 089 NRCA C402.3 N N N Vegetative roof
CE 090Roof Coating Manufacturers Assn
C402.3.1 N N N Roofs - adds new reflectance standard
CE 091Energy Efficient Code Coalition
C402.4, c402.4.3, Table
L W NCode change splits fenestration tables by height, 3 stories and less from those over 3.
CE 092Energy Efficient Code Coalition
Table c402.4
L W N Fenestration - SHGC values
CE 093Energy Efficient Code Coalition
Table C402.4, C402.4.3,
N N N Fenestration - SHGC values
CE 094Glazing Industry Code Committee
Table C402.4
N N N Fenestration - SHGC values
CE 095 DOETable C402.4
N N N Fenestration - SHGC values
CE 096 SEHPCACC402.4.1, C402.4.1.2,
N N N Skylights - toplight' zones
CE 097Glazing Industry Code Committee
C402.4.1.2
N N N Sets maximum skylight to 6%
CE 098 CO Chapter ICCC402.4.1, C402.4, C402.4.2
N N N Skylights - toplight' zones
CE 099Northwest Energy Codes Group
C402.4.2 N N N Skylights - toplight' zones
CE 100Energy Efficient Code Coalition
C402.4, C402.4.3
L W D Fenestration - eliminates projection factor
CE 101 JouanehC402.4.3.4 new
N W N Fenestration - shading
CE 102 CO Chapter ICCC402.4.4 new, C405.2.3.
N N N Relocate daylight zone determination
CE 103 CO Chapter ICC C402.5 N N N Masonry fireplaces - air leakage, doors
CE 104EPDM Roofing Assn
C402.5, C402.5.1
M S A Air barrier - inside or outside of thermal barrier.
CE 105 DOEC402.5 others
N W N Air leakage - reorganization
CE 106 zimmerC402.5; R402.4.1.2
N W N Air leakage testing - consistent with ASHRAE E62.2
CE 107New Building Institute
C402.5.1, C408.4 new
N W N Air barrier commissioning
CE 108 ahernC402.5.1.1
N N N Air barriers - piping penetrations
CE 109 CO Chapter ICCC402.5.1.1
N N N Air barriers - seams versus sealed
CE 110 ASHRAEC402.5.1.2.1
N N N Roof membranes
CE 111Plastic Glazing of ACC
C402.5.1.2.1.
N N N Insulation boards - removes "foil backed"
CE 112 NRCAC402.5.1.2.1
N N N Roof membranes
CE 113 HetzelTable C402.5.2
N N N Doors - power doors leakage rate
CE 114 SEHPCACC402.5; R402.4
N N N Rooms containing fuel burning appliances
CE 115 AGAC402.5; R402.4
N N N Rooms containing fuel burning appliances
CE 116 SEHPCAC C402.5.6 N N N Doors - loading docks
CE 117 Fairfax County C402.5.7 N N N Air curtains
CE 118 Fairfax CountyC402.5.7.1 new
N N N Unconditioned vestibules
CE 119 SEHPCAC C403 N N NMechanical Compliance (mandatory with prescriptive) reorganized
CE 120 CO Chapter ICC C403.2.1 M W ADesign loads - requires envelope, lighting, ventilation and occupancy loads
CE 121 ArmacellC403.2.10.1
N N N Mechanical - piping protection
CE 122 ASHRAEC202, C403.2.12, plus
N N N Mechanical - fan criteria
CE 123Air Movement Control Assn
C403.2.12.3
N N N Mechanical - kill label required
CE 124 SEHPCACC403.2.15, C403.2.16
N N N Walk-in coolers
CE 125 MathisC403.2.15, C403.2.16
N N N Walk-in coolers
CE 126 EEIC403.2.16 .1 new and- new
N N N Walk-in coolers
CE 127 Seattle C403.2.2 N N N Mechanical - equipment sizing
CE 128Northwest Energy Codes Group
C403.2.2, many more
N N N Mechanical - kill 'have capability'
CE 129 ASHRAEC403.2.3 all tables
N N N Mechanical - efficiencies
CE 130 EEITable C403.2.3(2)
N N N Mechanical - efficiencies
CE 131 EEItable C403.2.3(1)
N N N Mechanical - efficiencies
CE 132 EEITable C403.2.3(3)
N N N Mechanical - efficiencies
CE 133Northwest Energy Codes Group
C403.2.4.1, C403.2.4.
N N NMechanical - prevent same time heating and cooling
CE 134 FosterC403.2.4.1.1; R403.1.2
N N N Mechanical - heat pump
CE 135 EEIC403.2.4.1.1, R403.1.2
N N N Mechanical - heat pump supp heat
CE 136 ASHRAEC403.2.4.1.4new
N N N Conditioned vestibules
CE 137 AIA various N N N Mechanical - 'access to' equipment
CE 138 ASHRAEC403.2.4.3 new
N N N Mechanical - guest room HVAC controls
CE 139 ASHRAEC403.2.4.3
N N N Mechanical - shut off damper
CE 140 DOE C403.2.6 N N N Mechanical - ventilation
CE 141 SEHPCACC403.2.6.1
N N N Mechanical - demand control ventilation
CE 142 DOEC403.2.6.1
N N N Mechanical - demand control ventilation
CE 143 ASHRAEC403.2.6.3 new
N N N Mechanical - vent air heating control
CE 144Newport Ventures
C403.2.6.3 new
N N N Mechanical - ventilation of dwelling units
CE 145 ASHRAE C403.2.7 N N N Mechanical - laboratory energy recovery
CE 146 ASHRAEC403.2.9 new
N N N Mechanical - laboratory exhaust system
CE 147 AQC IndustriesC202, C403.2.9,R202,
N N N Mechanical - thermal distribution efficiency
CE 148 MacroAirC403.2.9.1.1-C403.2.9.
N N N Mechanical - pressure ducts
CE 149 SEHPCACC403.2.9.1.3
N N N Mechanical - high pressure ducts
CE 150 ASHRAETable C403.2.12.1(2)
N N N Mechanical - fan pressure drop
CE 151 ASHRAETable C403.2.3(8)
N N N Mechanical - heat rejection
CE 152 ASHRAETable C403.2.3(8)
N N N Mechanical - heat rejection
CE 153 EEITable C403.2.3(4)
N N N Mechanical - furnace efficiencies
CE 154 EEITable C403.2.3(5)
N N N Mechanical - boiler efficiencies
CE 155 ASHRAETable C403.2.7(1) Table
N N N Mechanical - energy recovery
CE 156 SEHPCACC403.3, C403.3.3, C403.3.4
N N N Mechanical - economizers
CE 157 SEHPCACC1041.4.1, C403.3
N N NMechanical - keeps residential and commercial portions in same building separate
CE 158 KWR EngineeringTable C403.3.(2)
N N N Mechanical - more exempt zones for economizers
CE 159 EEITable C403.4.1.1
N N NMechanical - removes outdated cooling system requirements
CE 160 ASHRAEC403.4.2.3.2
N N N Mechanical - heat rejection
CE 161 ASHRAEC403.4.2.4, C403.4.2.
N N N Mechanical - water temperature reset controls
CE 162 DOEC403.4.2.4, Table C403.4.2.
N N N Mechanical - load controls
CE 163 SEHPCACc403.4.2.6
N N N Mechanical - pump isolation
CE 164 SEHPCACC403.4.3 plus
N N N Mechanical - heat rejection
CE 165 ASHRAEC403.4.3 pplus
N N N Mechanical - heat rejection
CE 166 ASHRAE C404.4.4 N N N Mechanical - zone controls
CE 167 ASHRAEC404.4.4.6
N N N Mechanical- parallel flow variable air volume
CE 168 ASHRAEC404.4.4.7 new
N N N Mechanical - parallel flow variable air volume
CE 169 Aztec SolarC403.4.6 new; R403.13
N N N Solar heating systems installation
CE 170 NRDCTable C404.2
N N N Shower head water flow
CE 171 EEITable C404.2
N N N Water flow
CE 172 EEI C404.2.1 N N N Service water heating
CE 173 SEHPCAC C404.3 N N N Water - heat traps
CE 174 SEHPCACC404.7, R403.5
N N N Water - demand recirculation
CE 175 ScottsdaleC404.9 new; R403.5.5
N N N Shower head water flow
CE 176 APSAC404.9.3, R403.10.3
N N N Swimming pool covers
CE 177 EEIC404.9.3, R403.10.3
N N N Swimming pool covers
CE 178 SEHPCACC405 various
N N N Lighting controls
CE 179 IALDC405 various
N N N Lighting controls: dwelling, sleeping units
CE 180 EEI C405.1 N N N Lighting controls
CE 181 No Change N N N
CE 182 SEHPCACC405.2, C405.2.4
N N N Lighting controls
CE 183Northwest Energy Codes Group
C405.2 N N N Light level controls
CE 184 IALD C405.2.1 N N N Lighting terminology
CE 185 DOEC405.2.1, C405.2.1.1,
N N N Open office lighting
CE 186 SEHPCAC C405.2.1 N N N Automatic lighting controls
CE 187 DOEC405.2.1.1
N N N Time reduction for lighting controls
CE 188 IALDC405.2.2, C405.2.2.1
N N N Changes light automatic switch to timed switch
CE 189 IALDC405.2.2.1, C408.3.1.
N N N Light dimming controls
CE 190 CO Chapter ICCC405.2.2.1, C405.2.4
N N N Captive key for lighting controls
CE 191 IALDC405.2.2.3 vs C405.2.5
N N N Revision for manual lighting controls
CE 192 DOE C405.2.3 N N N New daylight controls
CE 193 IALDC405.2.3.2, C405.2.3.
N N N Removes existing building lighting
CE 194 NEMA C405.2.4 N N N Lighting clarify by adding system to devices
CE 195 IALDC405.2.5, C405.2.5.1 new
N N N Exterior lighting controls
CE 196 IALD C405.2.4 N N N Lighting override switch
CE 197 ASHRAEC405.2.5, C405.2.5.1 new
N N N Exterior lighting controls
CE 198 IALD C405.3 N N N Exit sign lighting
CE 199 EEI C405.3 N N N Exit signs lighting
CE 200New Building Institute
C405.2.4, C405.4 new
N N N Task lighting for plants growth
CE 201 SEHPCACC405.4 plus; C406.1
N N N Lighting power
CE 202 IALD C405.4.1 N N N Lighting power
CE 203 SEHPCAC C405.4.1 N N N Lighting power
CE 204 IALD C405.4.1 N N N Lighting power
CE 205 IALDTables C405.4.2
N N N Lighting power for dwellings
CE 206 IALDTables C405.4.2
N N N Lighting power
CE 207 IALDTables C405.4.2
N N N Adds classes of sports fields lighting
CE 208 DOETables C405.4.2
N N N Lighting power
CE 209 DOEC405.4.2.2.1
N N N Retail lighting
CE 210 DOEC405.4.2.2.1
N N N Lighting power
CE 211 SEHPCACC405.5 plus
N N N Exterior lighting
CE 212 IALD C405.5.1 N N N New lighting exceptions
CE 213 EEIC405.5.2 new
N N N No pilot lights
CE 214 Arlington CountyTable C405.5.1
N N N Additions to lighting
CE 215 IALDTable C405.5.1
N N N Lighting power
CE 216 DOETable C405.5.1
N N N Lighting power
CE 217Northwest Energy Codes Group
C405.5.2 new
N N N Outdoor lighting efficiency
CE 218 ASHRAEC405.6, C405.6.1 new
N N N Energy metering and monitoring
CE 219 ASHRAEC405.7 new
N N N Receptacle controls
CE 220 SEHPCAC C405.7 N N N Transformer efficiencies
CE 221 ASHRAETable C405.7
N N N Transformer efficiencies
CE 222 NEMAC405.8 new
N N N Energy metering and monitoring
CE 223 ASHRAE C405.8 N N N Revisions for small electric motors
CE 224 Seattle C405.9.2 N N N Escalator option
CE 225New Building Institute
C405.10 - new
N N N Load isolation
CE 226 ASHRAEC405.10 - new
N N N Voltage drop
CE 227 No Proposal
CE 228Northwest Energy Codes Group
C405.10 new
N N N Controlled receptacles
CE 229 Conner C406 new N N N Electric vehicle charging
CE 230Northwest Energy Codes Group
C406.1, M MO D UA (envelope) limits
CE 231 EEI C406.1 N N N Onsite power required
CE 232New Building Institute
C406.1 N N NMin from one to two increased efficiencies (HVAC, lighting power, lighting density, renewable, outside HVAC air or service water
CE 233 Foster C406.1 N N N New package for onsite energy storage
CE 234 EEI C406.1 N N N Service water
CE 235New Building Institute
C406.1.1 N N N Previously occupied spaces
CE 236 CO Chapter ICCC406.1.1, C503.7 new;
N N N Existing tenant space renewables.
CE 237 EEI C406.1.1 N N N Tenant space renewables
CE 238 Foster C406.2 N N N Non-listed equipment
CE 239 EEI C406.2 N N N Change equipment efficiency requirement
CE 240 EEI C406.2 N N N Non-listed equipment
CE 241 EEI C406.3 N N N Change lighting efficiency requirement
CE 242 SEHPCAC C406.5 N N N Min. ratings for on-site renewables
CE 243 EEI C406.5 N N N Min. ratings for on-site renewables
CE 244 EEI C406.5 N N N Expands power requirements
CE 245Northwest Energy Codes Group
C406.6 N N N Outdoor air systems
CE 246 Foster C406.7.1 N N N "On-site renewable" in lieu of "solar"
CE 247 NRDCC406.1, C406.8 new
N N N High-efficiency faucets
CE 248 EEIC407.1, R406.3
N N N Exempt vehicle recharging
CE 249 SeattleC407.2.1 new
L W D Max UA (envelope loss)
CE 250 SEHPCAC C407.3 N N N Renewables
CE 251 Scottsdale C407.3 N N N Limit renewables considered
CE 252National Propoane Gas Assn
C407.3 N N N Source of energy - new multipliers
CE 253 AGA C407.3 N N N Source of energy - new multipliers
CE 254 NowakC407.3.1 new
L W DSets criteria for alternative design minimizing flexibility
CE 255 ASHRAETable C407.5.1(1)
N N N Thermostat set points, schedules per ASHRAE 55
CE 256Air Movement Control Assn
Table C407.5.1(1)
N N N Thermostat set points, schedules per ASHRAE 55
CE 257 MacroAirTable C407.5.1(1)
N N N Thermostat set points, schedules per ASHRAE 55
CE 258 EEITable C407.5.1(1)
N N N Adds references to lighting controls
CE 259 AAMATable C407.5.1(1);
N N N Skylights
CE 260 CO Chapter ICC C408.1 N N N Add service water to commissioning
CE 261 ZimmerC408.1, C408.2
N N N Commissioning documentation
CE 262Northwest Energy Codes Group
C408.2 et al
N N N Certified professional
CE 263 CO Chapter ICCC408.2 et al
N N N Qualified authority
CE 264 CO Chapter ICC C408.2.1 N N N Qualified authority
CE 265 CO Chapter ICC C408.2.4 N N N Commissioning checklist
CE 266 CO Chapter ICC C408.2.4 N N N Construction documents - Consistency of terms
CE 267 CO Chapter ICCC408.2.4.1
N N N Construction documents - Report acceptance
CE 268Northwest Energy Codes Group
C103.6 new; C408
N N N Construction documents
CE 269 CO Chapter ICCC408.2.5.4, C408.3
N N N Lighting in commissioning
CE 270 Seattle C409 new N N N Solar readiness
CE 271 AIA C408 new N W N Adds new compliance option - zEPI
CE 272New Building Institute
C601 et al new
N W NAdds new section for multi-family. Probably a good concept
CE 273 StegallC101.2, C501.1
N N N Exempts low use buildings from code
CE 274 CO Chapter ICCC501.4, R501.4
N N N Adds IEBC to listed codes
CE 275 CO Chapter ICCC501.6, R501.6
N N N Historic buildings
CE 276 AIAC502.1, C503.1
N N N Editorial - corrects section references.
CE 277New Building Institute
C503.1, C503.7 new
N N N Roof replacements, over 50%, level 3 alterations
CE 278 ASHRAEC503.1, C503.6
N N N Lighting alterations
CE 279Northwest Energy Codes Group
C503.1 N N N Lighting alterations
CE 280Chicago Roofing Contractors Assn
C503.1.1 new
N N N Roof alterations
CE 281Chicago Roofing Contractors Assn
C503.1 N N N Roof alterations
CE 282Chicago Roofing Contractors Assn
C503.1 N N N Roof alterations
CE 283Chicago Roofing Contractors Assn
C503.1 N N N Roof alterations
CE 284 CO Chapter ICC C503.1 N N N Lighting alterations
CE 285 SeattleC503.2, C505.1
M O DMaintains minimum UA for performance compliance
CE 286Glazing Industry Code Committee
C503.3, C505.1
N N N Existing fenestration and skylight areas
CE 287 NRCA C503.3.1 N N N Roof replacement
CE 288Plastic Glazing of ACC
C503.3.2 new
N N N Skylight alternative
CE 289Plastic Glazing of ACC
C503.3.4 N N N Skylight alternative
CE 290New Building Institute
C503.4.2 new; C503.5.1
N N N Commissioning new systems in existing buildings
CE 291 SEHPCAC C503 et al N N N Lighting alterations
CE 292 RutgersC505.1, C505.2 new;
N N N Change of occupancy for lighting and intensities
CE 293 SeattleAppendix CA
N N N Requires renewable energy generation
CE 294 SEIAAppendix X
N N N Solar ready zone
CE 295 NEMA C405.1 N N N Electrical controls
CE 296 NEMA C405.7 N N N Controlled receptacles
CE 297 NEMA C302.1 N N N Design temperature
*** END OF SECTION IECC - COMMERCIAL ***
Desi
red
Com
mitt
ee
Asse
mbl
y
Desi
red
Asse
mbl
y
RE 001 MN Building Officials Assoc.
N1101.1, N1101.1.1 new
N N N Deletes the Note under the Scope Section and adds a new section with the information. Cleans up IECC
RE 002 Oregon Building Officials Assoc.
R103.2.1 N N N Clarifies component parts requirement for building thermal envelope on the submitted plans
RE 003 Energy Logic R202 N N N New definition air permeable insulation
RE 004 Norman (self) R202 N N N Change to high efficicacy lamps definition
RE 005 Edison Electric Institute
R202 N N N Change to high efficicacy lamps definition
RE 006 Dept. of Energy R202 N N N Change to high efficicacy lamps definition
RE 007 InterCode/Leading Builders of America
R202 N N N New definition Onsite Power Production
RE 008 SEHPCAC R202 N N N New definition for Opaque Door
RE 009 InterCode/Leading Builders of America
R202 N N N New definition for Renewable Energy
RE 010 Broan-nutone R303.4new N N N New definition Whole House Mech. Ventilation System
RE 011 Energy Efficient Codes Coalition
R401.2 N N N Deletes Energy Rating Index approach for compliance paths
RE 012 Edison Electric Institute
R401.2 L W N New language for Energy Index Rating, Energy Cost Index and Energy Use Index which grant new
RE 013 Energy Efficient Codes Coalition
R401.2.1 N N N Changes the method for cooling load calculation in tropical zone
RE 014 Energy Logic R401.3 N N N Certificate - deletes design professional. adds other approved party
IECC-RESIDENTIALImpact: H=High, M=Moderate, L=Low, N=None
Position: O=Oppose, S=Support, MO=Mild Opposition, MS=Mild Support, N = NoneAction: A=Approve, D=Disapprove, AM=Approve as Modified, W=Withdrawn
Desi
gnat
ion
Num
ber Proponent
Sect
ion
Impa
ct
PCA
Posi
tion
Committee Action
Publ
ic C
omm
ent Public
Comment
Fina
l Act
ion
Concept
RE 015 NAHB R402.4.1.2.1 N N N New test for multi-unit air tightness
RE 016 Institute for Market Transformation
multiple N N N Reorganizes building thermal envelope to mandatory requirements, reorganizes code in an
RE 017 Log and Timber Home Council
R402.1 N N N Adds a new reference to the Log Home Standard
RE 018 Energy Efficient Codes Coalition
Table R402.1.2 N N N Seek to increase min R values / Max U factor for floors in climate zones 2 and 4.
RE 019 Energy Efficient Codes Coalition
Table R402.1.2 N N N Seeks to lower ceiling R values and fenestration values
RE 020 Conner (self) Table R402.1.2 N N N Seeks to reduce ceiling insulation values to previous code values
RE 021 Foam Sheathing Committee
Table R402.1.2 N N N provides wood wall cavity and continuous insulation options
RE 022 ARES Consulting Table R402.1.2 N N N Seeks to improve the effectiveness of heated (radiant) slab insulation
RE 023 ARES Consulting Table R402.1.2 L O D New options for mass wall insulation values Concept of splitting interior and exterior mass is
RE 024 Glazing Industry Code Committee
Table R402.1.2 N N N Updates the prescriptive fenestration requirements Windows, Doors, and Skylights
RE 025 ASHRAE muliple N N N Adds new climate zone 0 requirement
RE 026 Kellen PIMA Table R402.1.2 N N N Provides addition compliance option for wood frame
RE 027 Kellen PIMA Table R402.1.2 N N N Options for cavity insulation and continuous insulation in all climate zones wall cavity
RE 028 APA, AWC Table R402.1.2 N N N Adds a prescriptive cavity-only wall insulation option in Climate Zones 6-8various values
RE 029 Norman (self) Table R402.1.2 N N N Adds new footnote for floor insulation values
RE 030 NAHB Table R402.1.2 N N N Provides an option for a thermally equivalent tradeoff for 2x6 wall assemblies
RE 031 NAHB Table R402.1.2 N N N Improves maximum allowable fenestration U-factors to match older ENERGY STAR specifications
RE 032 NAHB Table R402.1.2 N N N Prescriptive wall requirement increased to R-20+R5 in climate zones 6
RE 033 NAHB Table R402.1.2 N N N Climate Zone 3 wall criteria changed from R-13 to R-13+5 or R-20
RE 034 NAHB Table R402.1.2 L S A Lowers the basement wall insulation requirements
RE 035 National Resources Defense Council
Table R402.1.2; R103.2
N N N Change to the fenestration U-factor
RE 036 DOE Table R402.1.2 N N N Improves maximum allowable fenestration U-factors to match older ENERGY STAR specifications
RE 037 Energy Efficient Codes Coalition
Table R402.1.2 N N N Adds column for SHGC for Fenestration to the Table
RE 038 NAHB Table R402.1.2 N N N Changes ceiling U factor values
RE 039 Norman (self) R402.2.1 N N N Changes ceilings with attic spaces to overfill insulation.
RE 040 Kellen CPIA R402.2.2 N N N Allows for some limited lower R-Values for roof/ceiling
RE 041 Chicago Roofing contractors assn.
R402.2.2 N N N Addresses roof replacement on existing building.
RE 042 Chicago Roofing contractors assn.
R402.2.2 N N N Adds new exception for replacement roofs
RE 043 Chicago Roofing contractors assn.
R402.2.2 N N N Adds new exception R-value for roof assemblies with tapered insulation above roof deck
RE 044 Norman (self) R402.2.2 N N N Ceilings without attic spaces
RE 045 Dept. of Energy R402.2.5 new N N N Proposal allows wider wall stud spacing
RE 046 Norman (self) R402.2.3 N N N Low eave insulation provisions and baffles
RE 047 Energy Logic R402.2.3, R402.2.4 N N N Insulating installation criteria
RE 048 Oregon Building Officials Association
R402.2.4 N N N Attic access section is reworded.
RE 049 Norman (self) R402.2.4 N N N Attic access rewrite to include hinged doors and portals.
RE 050 Metro Atlanta Inspectors
R402.2.4 N N N Provide for a more permanent installed solution for vertical doors access
RE 051 American Wood Council
R402.2.5 M MS AM Adds CLT & HT wood into mass wall section (solid wood elements)
RE 052 MACS R402.2.5 H S A Corrects heat capacity for mass walls
RE 053 Steel Framing Alliance
Table R402.2.6 N N N Corrects insulation values for steel frame
RE 054 Foam Sheathing Committee
R402.2.7 N N N Wall sheathing R value changes
RE 055 Utah chapter ICC R402.2.14 new N N N Accessory buildings insulation and fenestration
RE 056 Maxwell (self) R402.4 N N N Air leakage rate testing
RE 057 Conner (self) R402.4 N N N Air leakage testing Changing the envelope air leakage rate from mandatory to prescriptive
RE 058 NAHB R402.4 N N N Removes the mandatory maximum air-tightness requirement from air leakage testing
RE 059 NAHB R402.4 N N N Group R-2 and 2 or more SFDwelling on air leakage
RE 060 Dept. of Energy R402.4 N N N Compliance options for homes w with higher envelope air leakage
RE 061 Bren Homes Table R402.1.1 N N N Window installation requirements
RE 062 Not used
RE 063 Ahern (self) Table R402.1.1 N N N Sealing mechanical penetrations
RE 064 Oregon Building Officials Association
Table R402.1.1 N N N Sealing of HVAC register boots installed in ceilings
RE 065 Oregon Building Officials Association
Table R402.1.1 N N N Provides for whatever the finish surface penetrations must be sealed
RE 066 Oregon Building Officials Association
TableR402.1.1 N N N Provides for air barrier behind tubs & showers
RE 067 Oregon Building Officials Association
Table R402.1.1 N N N Air barrier behind factory built fireplaces
RE 068 Colorado Chap. ICC Table R402.1.1 N N N Encapsulation of insulation during installation
RE 069 Energy Logic Table R402.1.1 L W N New definition on adiabatic, no heat loss of energy across a building assembly i.e. common walls
RE 070 Energy Logic Table R402.1.1 N N N Promotes a tighter building envelop, addresses the air barrier criterion for sprinklers
RE 071 Energy Logic Table R402.1.1 N N N deals with supply and return register boot sealing
RE 072 Energy Logic Table R402.1.1 N N N Sealing of Electrical boxes
RE 073 Energy Logic Table R402.1.1 N W N Air barrier at fireplace cavities added back into the air barrier and insulation Table
RE 074 Energy Logic Table R402.1.1 N N N Sealing plumbing and wiring penetrations
RE 075 Energy Logic Table R402.1.1 N N N Sealing of narrow cavities
RE 076 Energy Logic Table R402.1.1 N N N Clarification of the air barrier insulation Table
RE 077 Energy Logic Table R402.1.1 N N N Moves crawl space walls into mandatory criteria
RE 078 Energy Logic Table R402.1.1 N N N Helps to better define crawl spaces and floors over unconditioned spaces
RE 079 Energy Logic Table R402.1.1 N N N New definition of encapsulated, and rim joists encapsulating the insulation in a six sided cavity
RE 080 Energy Logic Table R402.1.1 N N N Insulation of space between the window sash and the framing of the w window
RE 081 Energy Logic Table R402.1.1 N N N New definition on encapsulated, air sealing of wall components
RE 082 Energy Logic Table R402.1.1 N N N New definition on encapsulated and Grade 1 insulation
RE 083 RESNET R402.4.1.2. N N N BSR/RESNET/ICC 380-2016 provides needed guidance for performing envelope air leakage, duct
RE 084 Braun-nutone R402.4.1.2 N N N Minor editorial changes to air leakage testing text
RE 085 Energy Logic R402.4.1.2 N N N New definition on dwelling unit enclosure area, leakage testing
RE 086 Energy Logic r402.4.1.2 N N N New section for testing garage separation air leakage
RE 087 NAHB R402.4.1.2 N N N Proposes 5 air changes per hour.
RE 088 Not used
RE 089 CAC R402.4.2 N N N Factory built fireplaces UL 127 new ref.
RE 090 Hearth Patio and BBQ assn.
R402.4.2 N N N Deletes UL907 reference for factory built fireplaces
RE 091 Conner (self) R402.4.4 N N N New except for intake openings and dampers in factory built fireplaces
RE 092 NAHB R402.4.4 N N N Deletes rooms with fuel burning appliances
RE 093 Not used
RE 094 Norman (self) R402.4.5 N N N Air leakage around recessed lighting
RE 095 Conner (self) R402.5 N N N Deletes maximum fenestration U-factor and SHGC (Mandatory).section
RE 096 Culp (self) R402.5 N W N Maximum fenestration
RE 097 Davies (self) R402.6 N N N New mandate for exterior slab insulation
RE 098 Steffes Corp R403.13 new N N N Energy storage
RE 099 NAHB R403.3.6 new N N N New section for ducts buried in insulation
RE 100 NAHB R403.3.6 new N N N New section for ducts buried in insulation
RE 101 Green seam R403.3.2 N N N Mechanical duct sealing
RE 102 NAHB R403.3.2 N N N Mechanical duct sealing
RE 103 Energy Efficient Codes Coalition
R403.3.3, R403.3.4 N N N Duct leakage and testing
RE 104 Cadmus Group/RESNET
R403.3.3 N N N Duct testing
RE 105 Broan-NuTone R403.3.3 N N N Duct testing
RE 106 Energy Logic R403.3.3 R403.3.4 N N N Duct testing
RE 107 Energy Logic R403.3.3, R403.3.4 N N N Duct testing
RE 108 NAHB R403.3.3, R403.3.4 N N N Duct testing
RE 109 CAC R403.3.5 N N N Use of building cavities as ducts
RE 110 NAHB R403.3.6 N N N Ducts buried in insulation
RE 111 Airex manufact. R403.4 N N N Piping insulation
RE 112 Airex manufact. R403.4.1 N N N Piping insulation
RE 113 National Resources Defense Council
R403.5.1 new N N N Hot water systems
RE 114 National Resources Defense Council
R403.5.5 new N N N Lavatory faucets
RE 115 National Resources Defense Council
R403.5.5 new N N N Showerheads
RE 116 Broan-NuTone self R403.6 N N N Mechanical vent methods
RE 117 Broan-NuTone self R403.6 N N N Mechanical vent methods
RE 118 Zimmer (self) R403.6 N N N New definition on habitable space and occupiable space and vent methods
RE 119 Broan-NuTone self R403.6.1 N N N Whole house vent
RE 120 Broan-NuTone R403.6.1 N N N Whole house vent
RE 121 Broan-NuTone R403.6.1 N N N Whole house vent
RE 122 CO Chapter ICC R403.6.1 N N N Whole house vent
RE 123 Dept. of Energy R403.6.1 N N N Whole house vent
RE 124 Energy Efficient Codes Coalition
R403.7 N N N Equipment efficiency
RE 125 Lutron R404.1 N N N Dimmers and auto shutoffs for lighting
RE 126 Lighting Designers R404.1 N N N Delete exception lighting equipment
RE 127 SEHPCAC R404.1 N N N Lighting equipment raising the minimum lighting efficacy from 75% to 90%
RE 128 IALD R404.1 N N N Lighting efficacy
RE 129 Norman (self) R404.1 N N N Lighting efficacy
RE 130 Edison Electric Inst. R405.1 N N N Lighting
RE 131 Edison Electric Inst. R405.1 N N N Vehicle recharge
RE 132 Dept. of Energy R405.1 N N N Mechanical ventilation
RE 133 Conner (self) R405.1 N N N Deletes redundant language on duct insulation
RE 134 NAHB R405.2; Table R405.5.2(1)
N N N Energy neutral trade-offs for equipment efficiency
RE 135 Energy Efficient Codes Coalition
R405.2 N N N Mandatory requirements for a minimum thermal envelope
RE 136 NRECA R405.3 N N N Electric generation
RE 137 Energy Efficient Codes Coalition
R405.3 N N N Efficiency of buildings and the accuracy of the performance path compliance option under
RE 138 Foster (self) R405.3 N N N Deletes energy source multiplier for electricity
RE 139 Edison Electric Inst. R405.3 N N N Energy generation
RE 140 Edison Electric Inst. R405.3 N N N Reference to the DOE Energy Information Administration's current publications for equipment
RE 141 Conner (self) R405.4 N N N On-site renewable energy
RE 142 Energy Logic R405.4.2 N N N Energy compliance reports
RE 143 Energy Efficient Codes Coalition
Table R405.5.2(1) N N N Air exchange rate requirements
RE 144 Conner (self) Table R405.5.2(1) N N N Equipment and device efficiency verification
RE 145 Conner (self) Table R405.5.2(1) N W N Removes glazing area from mandatory criteria
RE 146 Coalition for Fair Energy Codes
Table R405.5.2(1) N W N Removes glazing area from mandatory criteria
RE 147 Gas Technology Inst.
Table R405.5.2(1) N N N Heating/cooling water heating
RE 148 Lucas (self) Table R405.5.2(1) N N N Heating/cooling
RE 149 Broan-NuTone Table R405.5.2(1) N N N Mechanical ventilation
RE 150 NAHB Table R405.5.2(1) N W N Removes glazing area from mandatory criteria
RE 151 NEMA Table R405.5.2(1) N N N Energy losses through ductwork
RE 152 NEMA Table R405.5.2(1) N N N Space heating systems
RE 153 NEMA Table R405.5.2(1) N N N Grid interactive electric storage systems
RE 154 NEMA Table R405.5.2(1) N N N Equipment efficiency
RE 155 Conner (self) R406.1 N N N Deletes energy rating index (ERI) compliance alternative
RE 156 NAHB R406.2 N N N Thermal envelope minimums that are part of the new ERI compliance path mandatory requirements
RE 157 Energy Efficient Codes Coalition
R406.2 N N N Update the mandatory ERI requirements for the thermal envelope
RE 158 Energy Efficient Codes Coalition
R406.2 N N N Update the mandatory requirements for the thermal envelope in section 406.2
RE 159 Energy Efficient Codes Coalition
R406.2 N N N Computer software used on energy compliance
RE 160 Leading Builders of America
R406.2 N W N UA compliance
RE 161 Edison Electric Inst. R406 various N N N Editorial change to energy rating index
RE 162 Energy Logic R406.2, R406.4 N N N Solar energy calculations
RE 163 Edwards (self) R406.3 N N N ERI calculations
RE 164 Energy Efficient Codes Coalition
R406.3, R406.4 N N N On-site power
RE 165 Leading Builders of America
R406 N N N Refer to energy rating standard
RE 166 Cadmus Group/RESNET
R406 N N N Refer to energy rating standard
RE 167 Mathis (self) R406.3 N N N ERI calculations
RE 168 National Resources Defense Council
R406 N N N Refer to energy rating standard
RE 169 SEHPCAC R406.3.1 N N N Exclude vehicle charging
RE 170 Conner (self) R406 N N N Refer to energy rating standard
RE 171 NAHB R406.3.1 N N N Adds energy cost compliance as alternate to load
RE 172 NAHB Table R406.4 N N N Change ERI numbers
RE 173 Leading Builders of America
Table R406.4 N N N Change ERI numbers
RE 174 National Resources Defense Council
Table R406.4 N N N Change ERI numbers
RE 175 Leading Builders of America
R406.4.1 new N N N On-site power
RE 176 Cadmus Group/RESNET
R406.4.1 new N N N On-site power
RE 177 Inst. for Market Transformation
R406.4.1 new N N N On-site power
RE 178 Energy Logic R406.6.2 N N N Compliance reports
RE 179 Energy Efficient Codes Coalition
R407 new N N N Additional energy efficiencies flex point compliance method as addition option
RE 180 Conner (self) R407 new N N N Alternative compliance by equipment sizing
RE 181 Conner (self) R407 new N N N Compliance options by satisfying LEED silver
RE 182 Zimmer (self) R407 new N N N Commissioning
RE 183 CO Chapter ICC R502.1.1.2, R503.1.2
N N N Existing building HVAC
RE 184 Energy Efficient Codes Coalition
R503.1.1.1 N N N Replacement fenestration
RE 185 Norman (self) R503.1.1 N N N Exposed cavities in alterations
RE 186 Norman (self) R503.1.4 N N N Deletes exception on lighting
RE 187 NAHB Appendix RA N N N Deletes appendix venting systems
RE 188 AGA Appendix RA N N N Deletes appendix venting systems
RE 189 SEIA Appendix RB N N N Move appendix into IRC venting systems
RE 190 Dept. of Energy R403.5.3 new N N N Equipment efficiency information
RE 191 National Resources Defense Council
R303.1.5 N N N Water heater to delivery distance
*** END OF SECTION IECC - RESIDENTIAL ***
Desi
red
Com
mitt
ee
Asse
mbl
y
Desi
red
Asse
mbl
y
Concept
F 001 GBH 202 Accessibl
N N N Accessible vs. Access definition
F 002 UL 202 N N N ALCOHOL-BLENDED FUELS.
F 003 BCAC 202 N N N CO Alarm def
F 004 FCAC 202 N N N MSDS/SDS
F 005 Gregory Cahanin Hydrotech
202 N N N Asphalt Kettles
F 006 FCAC IFC (New) 304
N N N Dumpsters
F 007 William Freer NYS IFC 304.3.3
N N N Candles R-2 dorms
F 008 FCAC IFC 308.4.1
N N N Industrial trucks
F 009 William Freer NYS IFC 309.2, 5003.
N N N No smoking
F 010 Adhoc Health IFC: 310.2,
N N N No Smoking/oxy
F 011 Joe Boisseau IFC: 310.2,
N N N E-cigarettes
F 012 FCAC IFC: 310.9 (New)
N N N Access to vs Accessible
F 013 NYS IFC: 311.2.2
L AM AM Allow shut off of sprinkler system during off season when closed. Should be tied into construction type.
F 014 FCAC 311.2.2, 503.6,
N N N Code official
IFC - FIREImpact: H=High, M=Moderate, L=Low, N=None
Position: O=Oppose, S=Support, MO=Mild Opposition, MS=Mild Support, N = NoneAction: A=Approve, D=Disapprove, AM=Approve as Modified, W=Withdrawn
Desi
gnat
ion
Num
ber Proponent
Sect
ion
Impa
ct
PCA
Posi
tion
Committee Action
Publ
ic C
omm
ent Public
Comment
Fina
l Act
ion
F 015 SFPEIFC: 313, 313.1
N N N WATER MIST
F 016 William Freer NYS IFC: 314.4 N N N Indoor/vehicles
F 017 FP2FIRE IFC: 314.4 N N N Indoor/vehicles
F 018 WA state IFC: 105, 105.6.
L A A Permits pallet storage based on wall material
F 019 NYS IFC: 315.3.1
N N N Ceiling clearance
F 020 Jeffrey Shapiro IFC: 315.3.2
N N N Storage/MOE
F 021 Clark Co NV IFC: 315.3.2.1
N N N Storage Group A
F 022 Phoenix FD 105.6.49 (New),
N N N Vegatative roofs
F 023 FCAC IFC: 319 (New)
N N N Food Trucks
F 024 Phoenix FD IFC: 319 (New)
N N N Pool barriers
F 025 Phoenix FD IFC: 401.2 (New)
N N N confined spaces
F 026 Safer BuildingsIFC: 401.3.4 (Ne
N N N Public notification
F 027 Phoenix FD IFC: 401.8 (New)
N N N HAZMAT release
F 028 Phoenix FD IFC: 403.12.3,
N N N Responbility
F 029 FCAC IFC: 403.3.4,
N N N Crowd managers
F 030 Adhoc Health IFC: 404.2.
N N N Evacuation drills
F 031 FCAC 404.2.2, 408 (Ne
N N N Lockdown
F 032 Jack Murphy IFC: 404.2.3,
N N N Building information Card
F 033 FCAC IFC: 202, 407.2,
L W W Lockdown plans for schools.
F 034 Preview group IFC: 407.2.
N N N MSDS/SDS
F 035 Jay Weightman IFC: 503.1,
N N N MSDS/SDS
F 036 Robert Davidson IFC: 503.1.2,
M S A Does not permit an increase in fire access distance when using 13R or 13D
F 037 MACS IFC: 503.7 (New)
M S A Requires 2 access roads for type III, IV and V
F 038 Phoenix FD IFC: 507.5.7
M S AM Requires 2 access roads during construction when combustible arrive. Needs works to specify
F 039 Tim Knorr 508.1; IBC [F] 9
N N N FF Water marker
F 040 Phoenix FD 508.1; IBC [F] 9
N N N Fire Command Center
F 041 CA Fire Marshals 508.1.2, IBC [F]
N N N Fire Command Center
F 042 San Diego 508.1.3; IBC 911
N N N Fire Command Center
F 043 Matthew Davy 508.1.3, IBC [F]
N N N Fire Command Center
F 044 Clark Co NV 508.1.6; IBC [F]
N N N Fire Command Center
F 045 FCIA IFC: 509.1.2
N N N Fire Command Center
F 046 NYS IFC: 510.1.
N N N Marking of Solar
F 047 Safer BuildingsIFC: 510.3, [A]
N N N FF Radios
F 048 Safer Buildings IFC: 510.4.
N N N FF Radios
F 049 Pheonix FO IFC: 510.4.1,
N N N FF Radios
F 050 Safer Buildings IFC: 510.4.1.1,
N N N FF Radios
F 051 Safer Buildings IFC: 510.4.2,
N N N FF Radios
F 052 FCAC IFC: 510.4.2,
N N N FF Radios
F 053 CA Fire Marshals IFC: 510.4.2.1
N N N FF Radios
F 054 Safer Buildings IFC: 510.4.2.2.
N N N FF Radios
F 055 Safer Buildings 510.4.2.3, 604.2
N N N FF Radios
F 056 Sagiv Weiss-Ishai 510.4.2.3, 604.2
N N N FF Radios
F 057 Safer Buildings IFC: 510.4.2.4.
N N N FF Radios
F 058 Safer Buildings IFC: 510.4.2.5,
N N N FF Radios
F 059 Safer Buildings IFC: 510.4.2.6
N N N FF Radios
F 060 Safer Buildings IFC: 510.4.2.6
N N N FF Radios
F 061 Safer Buildings IFC: 510.4.2.6
N N N FF Radios
F 062 Safer Buildings IFC: 510.5.2.
N N N FF Radios
F 063 Safer Buildings IFC: 510.5.3.
N N N FF Radios
F 064 Safer Buildings IFC: 510.5.3.
N N N FF Radios
F 065 FCAC IFC: 510.6,
N N N FF Radios
F 066 Safer Buildings IFC: 510.6.1.
N N N FF Radios
F 067 Safer Buildings IFC: , 202 (New)
N N N FF Radios
F 068 Trickle Star IFC: , 202 (New)
N N N W Multiplug adapters
F 069 Trickle Star IFC: 603.1,
N N N Multiplug adapters
F 070 FCAC IFC: 603.3.2,
N N N Fuel oil storage
F 071 SFPE IFC: 603.4.
N N N WATER MIST
F 072 UL IFC: 603.4,
N N N Unvented heaters
F 073 Adhoc Health IFC: 604.1,
N N N Unvented heaters
F 074 GBH N N N NFPA 37
F 075 FCAC IFC: 604.4,
N N N Gas detection
F 076 Adhoc Health IFC: 604.6,
N N N I-2 emerg and standby power
F 077 Jeffrey Shapiro 604.2.6, 1105.10
N N N Emergency lighting testing
F 078 UL IFC: 604.1.2
N N N I-2 emerg and standby power
F 079 Vickie Lovell IFC: 605.3.1.
N N N piping protection
F 080 UL IFC: 605.4.1.
N N N NFPA 70
F 081 UL IFC: 605.5.
N N N Power tap design
F 082 UL IFC: 605.7.
N N N Extension cords
F 083 UL N N N Appliances
F 084 William Brooks 605.11 N N N Solar PV
F 085 Joe Cain N N N Solar PV
F 086 William Brooks 605.11 N N N Solar PV
F 087 NYS N N N Solar PV
F 088 IFFA N N N Solar PV
F 089 William Brooks IFC: 606.1.1
N N N Solar PV
F 090 Jeffrey Shapiro IFC: 606.8.
N N N Refrigeration
F 091 Pheonix FO IFC: 606.12.1.
N N N Refrigeration
F 092 Jeffrey Shapiro IFC: , 606.13, 6
N N N Refrigeration
F 093 Jim Tidwell IFC: 606.17
N N N Refrigeration
F 094 Julius Ballanco IFC 608 etc
N N N Refrigeration
F 095 FCACIFC: 608.1.
N N N Battery Systems
F 096 randy schubert IFC: 608.2 (New)
N N N Battery Systems
F 097 UL IFC: 608.5,
N N N Battery Systems
F 098 randy schubert IFC: 608.6.
N N N Battery Systems
F 099 randy schubert IFC: 608.6.1;
N N N Battery Systems
F 100 Jeffrey Betz IFC: 608.6.1;
N N N Battery Systems
F 101 randy schubert IFC: 608.6.3;
N N N Battery Systems
F 102 Jeffrey Betz IFC: 608.6.3;
N N N Battery Systems
F 103 randy schubert IFC: 608.9,
N N N Battery Systems
F 104 Jeffrey Betz (NEW) Section
N N N Battery Systems
F 105 Matt Paiss (NEW) Section
N N N Battery Systems
F 106 Celina Mikolajczak 604, 605.11,
N N N Battery Systems
F 107 UL IFC: 608.10
N N N Commercial kitchens
F 108 UL IFC: 608.10
N N N Commercial kitchens
F 109 UL IFC: [M] 609.2.
N N N Grease extractors
F 110 FCAC IFC: 609.3.1.
N N N Cooking oil
F 111 FCAC IFC: 609.3.2.
N N N Storage tank
F 112 FCAC 610.3 L ? ? Battery storage Watch
F 113 FCAC Chapter 7 N N N CH7/rewrite
F 114 Tony Crimi IFC: 701.3 (New)
N N N Penetrations
F 115 FCIA IFC: 703.1,
M S A Requires maintenance of fire assemblies equal to construction
F 116 PCA IFC: 703.1.3.
N W Prefer F116, Withdrawn by PCA
F 117 FCIA IFC: 703.1.4
M S A Requires marking when using spray on or intumescent coatings
F 118 GBH IFC 803 N N N Interior finish
F 119 GBH IFC: 803.1.
M S A Requires Type IV exit testing
F 120 Adhoc Health IFC: Table 803.3
N N N Interior finish
F 121 GBH IFC: 803.4.
M S A Requires more stringent testing for spray-on fire coatings. Must be tested with the intended
F 122 GBH IFC: 803.5.1.
N N N Interior finish
F 123 GBH IFC: 803.5.1.1.
N N N Interior finish
F 124 GBH IFC: 803.11
N N N Interior finish
F 125 GBH IFC: 804.3.1,
N N N Interior trim and floors
F 126 GBH IFC: 805.1.1.2,
N N N Heat release rate
F 127 Adhoc Health IFC: 805.2,
N N N I-2 and ambulatory
F 128 GBH IFC: 202 (New),
N N N Upholstered furn
F 129 Not Used IBC: 806.3 (New)
N N N Not used
F 130 GBH 806, 806.2,
N N N Decorative veg
F 131 GBH IFC: 806.1.4
N N N Decorative veg
F 132 CTC Care IFC: 806.2.
N N N Decorative veg
F 133 Amy Carpenter IFC: 806.2.
N N N Decorative veg
F 134 FCAC 807.1 (IBC [F] 8
N N N Decorative materials
F 135 Clark Co. NV IFC: 807.3 (IBC:
N N N Decorative materials
F 136 Bob Morgan 807.3 (IBC [F] 8
N N N Decorative materials
F 137 Adhoc Health IFC: 808.1.
N N N Waster containers
F 138 Adhoc Health IFC: 808.1,
N N N Waster containers
F 139 GBH IFC: 809 (New),
N N N Child play structures
F 140 FCAC IFC: 901.1.
N N N Chapter 9 scope
F 141 FCAC 901.4.6, 903.3,
N N N sprinkler riser room
F 142 Fire Sprinkler Assoc. IFC: 901.4.7
N N N Freeze protection
F 143 Fire Sprinkler Assoc. IFC: 901.5,
N N N Fire prot systems
F 144 Thomas Hammerberg
202 (New),
N N N NFPA 4
F 145 FCAC 202, 901.6.2
N N N NFPA 4
F 146 FCAC IFC: 901.6.3
N N N notification testing
F 147 PCA IFC: 901.7.
L S A Requires occupants to be notified when sprinklers are out of service.
F 148 PCA IFC: 901.7.6.
L S A Requires occupants to be notified when sprinklers are back in service.
F 149 Bob Morgan IFC: 901.8.2.
N N N Hose lines
F 150 Fire Sprinkler Assoc. IBC: 901.9 (New)
L S A Requires sprinkler system in Risk Cat. III and IV, over 1000 sq. ft.
F 151 Jay Hyde 901.11 (New)(IBC
N N N Occupant threshold
F 152 Seattle IFC: 903.2 (IBC:
N N N Group A Org
F 153 FCAC 903.2.1(IBC [F]
N N N Grandstands
F 154 Adhoc Health IFC 304.1.3,
N N N Ambulatory care
F 155 Earl Shoemaker 903.2.2 (IBC [F]
N N N Exception dentistry
F 156 Gerald Anderson IFC: 903.2.2
N N N Group E
F 157 Clark Co. NV IFC: 903.2.3
N N N Group E
F 158 Fire Sprinkler Assoc. 903.2.3 (IBC [F]
M AM AM Requires Group E (schools) be sprinklered if fire area > 4500 sq. ft. Also E with storm shelter. AM for
F 159 William King IFC: 903.2.3
N N N Upholstered furn
F 160 Marcus Dunn 903.2.7 (IBC [F]
N N N Upholstered furn
F 161 John England903.2.9 (IBC [F]
N N N Upholstered furn
F 162 Jay Hyde IFC: 903.2.9
N N N Upholstered furn
F 163 UL IFC: 903.2.10
N N N Stories w/o openings
F 164 Clark Co. NV 903.2.11.1 (IBC
N N N Commericial kitchen
F 165 CTC Care 903.2.11.5 (IBC
N N N R-4
F 166 San Diego 903.3.1.1.2 (IBC
N N N Non comb canopies
F 167 Robert Davidson IFC: 903.3.1.1.
H S A Measure story height from grade plane
F 168 PCA 903.3.1.2 (IBC [
H S A Fall back to F171-16
F 169 AWC 903.3.1.2 (IBC [
H O D Measuring height. This will not hurt us and is more restrictive than what we currently have.
F 170 PCA IFC: 903.3.1.2
L S A Clarifies in chapter 9 when balcony sprinklers are required. Needs modification to simply referecne
F 171 Robert Davidson 903.3.1.2.1 (IBC
H S A Requires attic sprinkler protection at 30 ft.
F 172 Jeffrey Shapiro/FCAC
903.3.1.2.3 (New
H O D Requires attice sprinkler protection at 55 ft. to roof. This is more restrictive than current provisions, but
F 173 PCA 903.3.1.2.3 (New
L S A Brings forth sprinkler obstruction requirements
F 174 Lori Jessell 903.3.3 (IBC [F]
N N N NFPA 96
F 175 SFPE 904.12 (IBC [F]
N N N WATER MIST
F 176 UL 904.12 (IBC [F]
N N N Cooking extinguisher
F 177 CTC Care 904.12.5, 904.12
N N N I-1 cooking
F 178 CTC Care 904.13 (IBC [F]
N N N recirculating air
F 179 FCAC 904.13 (IBC [F]
N N N domestic cooking
F 180 Anthony Gee 904.13 (IBC [F]
N N N Aerosol systems
F 181 Kevin Kelly 901.6.1, 904.13
N N N Hybrid
F 182 SFPE904.14 (New) (IB
N N N WATER MIST
F 183 David Kerr 905 (New)
N N N Standpipe caps
F 184 NYS 905.3.1 (IBC [F]
N N N Standpipes
F 185 NYS 905.3.1 (IBC [F]
N N N Standpipes
F 186 Roofing 905.4 (IBC [F] 9
N N N Vegatative Roofs
F 187 Raymond Grill 905.4, (IBC [F]
N N N Standpipes
F 188 Jeffrey Shapiro 905.12 (New) (IB
N N N Stanpipe hose
F 189 Dave Frable 906.1 (IBC [F] 9
N N N Portable extinguishers
F 190 Jim Tidwell 906.1 (IBC [F] 9
N N N Portable extinguishers
F 191 Michael Anthony 906 N N N Portable extinguishers
F 192 FCAC IFC: 906.2.
N N N Fire alarm drawings
F 193 Clark Co. NV IBC: [F] 906.2.
N N N Group A
F 194 Bob Morgan 907.1.2 (IBC [F]
N N N Group A
F 195 FCAC 907.2.1 (IBC [F]
N N N Group A
F 196 CTC Care 907.2.1 (IBC [F]
N N N R-4 alarm
F 197 Clark Co. NV 907.2.1 (IBC [F]
N N N Multi channel voice
F 198 Adhoc Health 907.2.10 (IBC [F
N N N Ambulatory
F 199 Pheonix FO 907.2.13.3 (New)
N N N Group I communications
F 200 PCA IFC: 907.2.2
L S A Removes sprinkler trade off to eliminate pull stations when 13R is used in R-1 and R-2
F 201 San Diego 907.2.6 (IBC [F]
N N N Group R-2
F 202 Thomas Hammerberg
907.2.8.1 (IBC [
N N N Control function
F 203 FCAC IFC: 907.2.9.1
N N N Special locking
F 204 FCAC 202 (IBC [F] 202
N N N Distance of travel
F 205 NYS IFC: 907.3.2
N N N Private mode
F 206 CA Fire Marshals 907.4.2.1 (IBC [
N N N Emerg voice/alarm
F 207 Lynn Nielson 907.5.2.1 (IBC [
N N N Intellibgibility
F 208 Thomas Daly 907.5.2.2.4 (IBC
N N N R2 dorms visible
F 209 FCAC 907.5.2.2.6 (New
N N N Visible alarm distribution
F 210 Dominic Marinelli 907.5.2.3.2 (IBC
N N N Visible alarm distribution
F 211 Dominic Marinelli 907.5.2.3.2 (IBC
N N N R2 dorms visible
F 212 FCAC 907.5.2.3.2 (IBC
N N N Visible alarms
F 213 Thomas Hammerberg
907.5.2.3 (IBC [
N N N Visible alarms
F 214 CA Fire Marshals 907.5.2.3.2 (IBC
N N N Visible alarms
F 215 FCAC 907.5.2.3.3 (IBC
N N N smoke alarm maintenance
F 216 FCAC 907.5.2.3.3 (IBC
N N N smoke removal
F 217 Kellen IFC: 907.10
N N N IBC 716
F 218 Victor Cuevas 202 IBC and IFC
N N N Smoke zones
F 219 Bob Morgan 909.1 (IBC [F] 9
N N N Pressuized stairways
F 220 FCAC N N N Smoke and heat maint.
F 221 FCAC IFC: 909.5.3,
N N N Connection locations
F 222 Don Davies IECC: C402.5.4.
N N N CO Assembly
F 223 CTC Care IFC: 909.6.1
N N N CO Group I-4
F 224 FCAC IFC: 909.22
N N N CO
F 225 FCAC IFC: 910.5,
N N N CO garages
F 226 Jeffrey Shapiro 912.2 (IBC [F] 9
N N N Gas detection
F 227 Pheonix FO N N N MASSNOT
F 228 FCAC IFC: 202 (New)
N N N MASSNOT
F 229 FCAC IRC: 202 (New)
N N N Locking arrangement
F 230 FCAC IFC: 915.1,
N N N Emerg escape
F 231 FCAC 915.1.1, 915.2.3
N N N CH11 applicability
F 232 BOMA 915.1.3, 915.1.4
N N N IEBC allowance
F 233 CTC Care IFC: 915.6.1
N N N CH11 Coordination
F 234 Morgan Hurley 105.7.19 (New),
N N N FF Radio exist
F 235 FCAC 202, 202 (New),1
N N N CH11 Coordination
F 236 Adhoc Health IBC: [F] 1001.3
N N N Ambulatory care elevator
F 237 Bryan Romney IFC: 1031.2.2
N N N Vertical openings
F 238 FCAC IFC: 1031.7.
N N N Group A-2 retroactive sprinkler
F 239 FCAC IFC: 1101.2,
N N N CO existing
F 240 CTC Care IFC: 1103.1.
N N N Emerg illum existing
F 241 FCAC IFC: Table 1103.
N N N Emerg illum existing
F 242 Adhoc Health IFC: 1103.2.
N N N Emerg power I-2
F 243 FCAC Table 1103.1,
N N N Door size exist
F 244 Adhoc Health IFC: 1103.3.1.
N N N Door size I-2 and Ambulatory
F 245 Kellen IFC: 1103.4,
N N N Door size exist
F 246 BOMA Table 903.2.11.
N N N Fire escape openings
F 247 FCAC IFC: 1103.9.
N N N Dead ends exist
F 248 CTC Care IFC: 1104.5.
N N N Occup clarification
F 249 FCAC 1104.5, 1104.5.1
N N N Aisle width exist
F 250 Adhoc Health IFC: 1104.5.1,
N N N I-2 sprink existing
F 251 Tony Crimi IFC: 1104.7,
N N N Fire resistance exception
F 252 Tony Crimi IFC: 1104.7,
N N N corridor continuity
F 253 Adhoc Health IFC: 1104.7,
N N N I-2 automatic hold open
F 254 Adhoc Health IFC: 1104.16.2
N N N I-2 door plates exist
F 255 Adhoc Health 1104.18, Table 1
N N N I-2 essential power
F 256 Adhoc Health IFC: Table 1104.
N N N I-2 essential power
F 257 Jay Weightman IFC: 1104.23.
N N N Vehicle documentation
F 258 Robert Davidson 1105.2 (New), 11
N N N DUST
F 259 Veronica Tinney IFC: 1105.4.2.
N N N DUST
F 260 UL IFC: 1105.4.3.
N N N NFPA 30A
F 261 CA Fire Marshals IFC: 1105.5.4
N N N Emerg disconnect
F 262 Jeffrey Shapiro IFC: 1105.6.3.
N N N Separation of tanks
F 263 Richard Kraus IFC: 1105.10,
N N N API 1646
F 264 FCAC IBC: [F] 412.6,
N N N Protect above tank
F 265 UL IBC: [F] 412.6.3
N N N NFPA 30A
F 266 UL IFC: 2006.4.1.
N N N Dispenser listing
F 267 NYS 2201.1, 2203.1 (
N N N Impact protect
F 268 Richard Kraus IFC: 2204.1.
N N N ethanol and gas/ethanol
F 269 Bruce Swiecicki 202 N N N Dispensers
F 270 Robert Davidson IFC: 2301.1.
N N N hyrdogen
F 271 Dan Bowerson IFC: 2303.2.1
N N N LNG, CNG repair
F 272 Robert Davidson IFC: 2305.1.1,
N N N Gas fuel repair
F 273 Dan Bowerson IFC: 2305.2.
N N N Gas fuel repair
F 274 Robert Davidson IFC: 2306.2.3.
N N N Exhaust vent
F 275 Robert Davidson IFC: 2306.7.
N N N Motor vehicle repair rooms, booth space
F 276 Robert Davidson IFC: 2306.8.1.
N N N NFPA 2
F 277 Dan Bowerson IFC: 2306.7.3.
N N N IMC ventilation rates
F 278 Robert Davidson IFC: 2306.8.
N N N Gas detection
F 279 Dan Bowerson IFC: 2307.2,
N N N Operation gas detect
F 280 Dan Bowerson IFC: 2309, 2309.
N N N Failure gas detect
F 281 Robert Davidson 2311.5, 2311.5.1
N N N Classified Electrical
F 282 Geoffrey Raifsnider IFC: 2311.5,
N N N Spray booth electrical
F 283 FCAC IFC: 2311.7.
N N N Spray rooms
F 284 SFPE IFC: 2311, 2311.
N N N WATER MIST
F 285 Geoffrey Raifsnider 105.7.13 (New),
N N N Spray booth size
F 286 NYS 2311.7 N N N testing interlock
F 287 NYS IFC: 2311.7.1.
N N N testing interlock
F 288 NYS IFC: 2311.7.2.
N N N testing interlock
F 289 Geoffrey Raifsnider IFC: 2311.7.2.
N N N air circulation
F 290 NYS IFC: 2311.7.2.
N N N testing interlock
F 291 NYS 2311.7, 2311.7.3
N N N testing interlock
F 292 SFPE IFC: 2403.2.1.
N N N WATER MIST
F 293 Patrick McLaughlin 202, 2404.2,
N N N Semiconductor
F 294 Robert Davidson IFC: 2404.2,
N N N W Bale stacks
F 295 William Koffel IFC: 2404.3.2.
N N N outdoor pallets
F 296 NYS IFC: 2404.6.1.
N N N testing interlock
F 297 NYS IFC: 2404.7.1,
N N N
F 298 Lori Jessell/California
IFC: 2404.8.1.
N N N TENT/Umbrella structure
F 299 GBH - GBH Fire Sprinkler Assoc. -
IFC: 2404.8.2,
N N N TENT/spec amuse
F 300 FCAC IFC: 2405.8,
N N N TENT/structural requirements at 4000 Sq. Ft
F 301 N
F 302 Thomas Markel - IFAI
IFC: 3103.7,
N N N TENT/inspect
F 303 GBH - GBH IFC: 3104.2.
N N N TENT/NFPA 701
F 304 Thomas Markel - IFAI
IFC: 3104.2,
N N N TENT/Flame propag
F 305 Thomas Markel - IFAI
IFC: 3104.12.
N N N TENT/Fire extinguishers
F 306 Bruce Swiecicki - National Propane
IFC: 3104.16,
N N N TENT/LPG
F 307 FCAC IFC: 3105.1,
N N N TENT/ANSI E1.21
F 308 FCAC 105.6.45, 105.7.
N N N TENT/ADDS Temporary Special Event Structure
F 309 FCAC 3101.1, 3103.1,
N N N TENT/Operational requirements
F 310 FCAC 105.6.36 (New),
N N N TENT/Outdoor Assembly Event
F 311 FCAC IFC: 105.6.23,
N N N CH32/Permits
F 312 FCAC IFC: 3201.3,
N N N CH32/Constr docs
F 313 FCAC IFC: 3201.4,
N N N CH32/Evacuation plan
F 314 FCAC IFC: , 3203.1, 3
N N N CH32/Commodity class
F 315 FCAC IFC: 3204.1.
N N N CH32/Clarifiation
F 316 FCAC IFC: 3206.1,
N N N CH32/Access
F 317 Phoenix FO IFC: Table 3206.
N N N CH32/Frozen food
F 318 FCAC IFC: 202, 3206.2
N N N CH32/Extent protect
F 319 FCAC IFC: Table 3206.
N N N CH32/2 hr sep
F 320 FCAC IFC: Table 3206.
N N N CH32/Max pile dimensions
F 321 FCAC IFC: Table 3206.
N N N CH32/Clarification
F 322 Pheonix FO IFC: 3206.4.2
N N N CH32/Spec build
F 323 FCAC IFC: 3206.9.1.
N N N CH32/Aisles
F 324 FCAC 3208.3, Table 32
N N N CH32/Flue spaces
F 325 FCAC IFC: 3209.4,
N N N CH32/Automated
F 326 UL IFC: 3303.1.
N N N Temp heating
F 327 Robert Davidson IFC: 3304.5,
L S A Requires fire watch during working hours
F 328 Robert Davidson IFC: 3304.5.
H S A Requires fire watch for combustible construction over 2 stories.F
F 329 San Diego 3304.5.1 (New);
H S A Requires fire watch for combustible construction over 40 ft.
F 330 FCAC IFC: 3304.6.
N N N Cutting and welding
F 331 Jeffrey Shapiro IFC: 3304.8
N N N Cooking areas
F 332 FCAC IFC: 3308.6.1
N N N Smoke detect and alarms
F 333 Robert Davidson IFC: 3310.1,
H S A Requires increased fire dept. access for combustible construction
F 334 Mark Nowak IFC: 3310.1.
H S A Prefer F333
F 335 Edward Kulik IFC: 3311.2
N N N Maint MOE
F 336 Stephen Skalko 3314.2 (New) (IB
H S A sprinklers active during construction
F 337 Joe Scibetta Chapter 38 (New)
N N N Animal Housing Facility
F 338 FCAC Chapter 38 (New)
N N N Processing and Extraction
F 339 Robert Davidson Chapter 38 (New)
N N N Non production labs
F 340 FCAC Chapter 38 (New)
M ? Allows more H material
F 341 Robert Davidson IFC: , 105, 105.
N N N Processing and Extraction
F 342 Ellie Klausbruckner IFC: 5001.1.
N N N Alcohol wipes
F 343 Jay Weightman IFC: 5001.3.3.
N N N Gas detection
F 344 Ellie Klausbruckner Table 5003.1.1;
N N N DUST
F 345 Patrick McLaughlin Table 5003.1.1,
N N N Class 3 oxidizer
F 346 FCAC Table 5003.1.1;
N N N Explosives 1.4G
F 347 FCAC 202, 5003.1.1,
N N N Fireworks
F 348 Robert Davidson IFC: 5003.1.5
N N N Group H classification
F 349 Martin Gresho IFC: 5003.2.2.
N N N Emergency isolation
F 350 FCAC IFC: 5003.3.1.
N N N unauthorized discharge hazmat
F 351 not used N N N Not used
F 352 FCAC Table 5003.8.2;
N N N Detached buildings
F 353 San Diego 5003.8.3.2; IBC
N N N Max allowa control areas
F 354 San Diego Table 5003.8.3.
N N N Control area design and number
F 355 AWC 5003.8.3.4; IBC
L O D Allows Type IV to be reduced to 1 hour if sprinkled and < 4 stories
F 356 Homer Maiel, PE 5003.8.3.5 (New)
N N N Control area Group M
F 357 Adhoc Health IFC: 5003.9,
N N N Emergency showers
F 358 FCAC IFC: 5003.9.8.
N N N Incompatible gases
F 359 Sarah Rice IFC: 5004.3.
N N N Ventilation
F 360 FCAC IFC: 5004.7.1.
N N N Exempt standby and emerg clarification
F 361 Patrick McLaughlin IFC: 202 (New),
N N N Aerosol cooking spray
F 362 Patrick McLaughlin IFC: 5103.2,
N N N plastic aerosols
F 363 Patrick McLaughlin 202, 907.2.16
N N N Aerosol products
F 364 Robert Davidson IFC: 5301, 5301.
N N N NFPA 2
F 365 Bruce Swiecicki IFC: 5301.1.
N N N LPG CH61
F 366 Robert Snyder IFC: 5306, 5306.
N N N Medical gases
F 367 Adhoc Health IFC: 5306.1.
N N N Medical gases
F 368 Adhoc Health IFC: 5306.2,
N N N Medical gases
F 369 Jeffrey Shapiro/FCAC
916 (New)
N N N Compressed gas
F 370 FCAC 105.6.4, Table 1
N N N Liquid CO2
F 371 Jay Weightman IFC: , 105.6.4,
N N N CO2
F 372 FCAC 105.6.5 (New), T
N N N CO2 enrichment
F 373 Jay Weightman IFC: , 5506
N N N Cryogenic inert gas systems
F 374 FCAC 202, Table
N N N 56 seaparation distances
F 375 NYS IFC: 5605.5.1.
N N N testing interlock
F 376 Ellie Klausbruckner IFC: 5701.2.
N N N Alcohol wipes
F 377 Richard Kraus IFC: 5703.1.3
N N N Electrical installations/API Standards
F 378 Vickie Lovell IFC: 5703.6.2.
N N N fire resistant piping protection
F 379 Richard Kraus IFC: 5704.2.7.
N N N API standards
F 380 Leslie Townzen IFC: 5704.3.4.
N N N S1 increases Flammable and combustible liquids
F 381 Sarah Rice IFC: 202, 5704.3
N N N Liquid storage warehouse
F 382 Jeffrey Shapiro IFC: 5705.2.1.
N N N Positive displacement pumps
F 383 SFPE IFC 5705.5
N N N WATER MIST
F 384 Richard Kraus IFC 5706.3.5
N N N API standards
F 385 Richard Kraus IFC 5706.4.5
N N N API standards
F 386 Mike Halligan IFC 5706.5.4.
N N N Mobile fueling
F 387 Richard Kraus IFC 5706.7
N N N API standards
F 388 Richard Kraus IFC 5706.7.2
N N N API standards
F 389 NYS IFC 5906.5.4,
N N N Annual testing
F 390 Bruce Swiecicki IFC 6103.2.1.
N N N LPG
F 391 FCAC IFC 6103.2.1.
N N N LPG LABS
F 392 Bruce Swiecicki IFC 6103.2.1.
N N N LPG
F 393 Bruce Swiecicki IFC 6104.3, T
N N N LPG
F 394 Bruce Swiecicki IFC Table 6104.3
N N N LPG
F 395 Bruce Swiecicki IFC 6109.3
N N N LPG
F 396 Bruce Swiecicki IFC 6109.7
N N N LPG
F 397 Bruce Swiecicki IFC 6109.8
N N N LPG
F 398 Bruce Swiecicki IFC 6109.9
N N N LPG
F 399 Bruce Swiecicki IFC 6110,
N N N LPG
F 400 Paul Vinje C102.1 N N N Fire Flow
F 401 Joseph Hetzel D103 N N N Apparatus gates
F 402 Kirk Mitchell E102.1.7 N N N liquid and solid oxidizers
F 403 Ellie Klausbruckner Table F101.2
N N N HAZMAT
F 404 NYS Appendix H
N N N HAZMAT
F 405 Adhoc Health IFC: K102.2.2
N N N AMBULATORY
F 406 Adhoc Health IFC: K102.3,
N N N AMBULATORY
F 407 Adhoc Health IFC: K102.5
N N N AMBULATORY
F 408 Fire Sprinkler Assoc. IFC M103 Complia
N N N
F 409 GBH - GBH FCAC
(NEW) Appendix
N N N TENT/ Tradeshow
F 410 Thomas Markel - IFAI
(NEW) Appendix
N N N TENT
F 411 NYS (NEW) Appendix
N N N Processing and Extraction
F 411 Mike Halligan (NEW) Appendix
N N N Mobile fueling
Desi
red
Com
mitt
ee
Asse
mbl
y
Desi
red
Asse
mbl
y
RB 001 VSI (Vinyl) R106.1.2.1 L W D Establishes new provisions for product maintenance
RB 002 Collins R308.4 N N N Revises "access" and adds "ready access" Appears to be editorial to remove "readily accessible"
RB 003 ARMA (Asphalt Roof)
R202 N N N Limits vented attics to steep roofs
RB 004 Hope Medina R202 N N N Adds definition for bedroom that includes "with a clothes rod and shelf within the room"
RB 005 Brian Johnson R202 N N N Adds definition for blocking but limited it to wood
RB 006 R. Davidson R202 N N N Adds crawlspaces as "An under floor space that is not a basement" This should be modified as
RB 007 BCAC R202 N N N Adds definition for detached
RB 008 R. Davidson R202 N N N Editorial on draftstop
RB 009 R. Davidson R202 N N N Clarifies and removes extraneous language on "dwelling"
RB 010 CO Chapter ICC R202 N N N Adds "located on a single lot that are" to "dwelling"
RB 011 R. Davidson R202 N N N Removes sanitation from definition of dwelling unit
RB 012 San Diego R202 M S A Clarifies measuring the distance as from face of wall covering and not from foundation wall
RB 013 No Change Posted
RB 014 R. Davidson R202 N N N Stair riser - stair is minimum of two risers not one
IRC - RESIDENTIALImpact: H=High, M=Moderate, L=Low, N=None
Position: O=Oppose, S=Support, MO=Mild Opposition, MS=Mild Support, N = None, W= WatchAction: A=Approve, D=Disapprove, AM=Approve as Modified, W=Withdrawn
Desi
gnat
ion
Num
ber Proponent
Sect
ion
Impa
ct
PCA
Posi
tion
Committee Action
Publ
ic C
omm
ent Public
Comment
Fina
l Act
ion
Concept
RB 015 R. Davidson R202 L S A Adds clear width of yard to townhouse definition
RB 016 No Change Posted
RB 017 Cobeen, WJE, FEMA, BSSC
R301.2 L W A Updates to new USGS seismic maps
RB 018 OR Earthquake Awareness
R301.2 M W D Replaces SDC with Lateral design strength maps
RB 019 IBHS R301.2 M W A Removes contours for WA, OR, ID, MT, CO, and NM in favor of ASCE 7 Table 7.3
RB 020 IBHS R301.2 H S A Coordinates wind with ASCE 7-16 - increasing wind speed
RB 021 Medina (Coloradocode)
301.2 N N N Climate and geographic reporting
RB 022 Oregon Earthquake Awareness
301.2.2 M W D Seismic design - reverts back to old lateral force design
RB 023 BCAC 301.2.2 L W D Seismic design - Clarification seems confusing
RB 024 BCAC 301.2.2 N N N Revises seismic design criteria
RB 025 R. Davidson 301.5 N N N Clarifies load conditions - guard rails
RB 026 Seattle 301.5 M S A Increases balcony loads by 1.5
RB 027 WABO 301.5 M S A Increases balcony loads 40 to 60
RB 028 S NV ICC 301.6 N N N Adds IBC option for roof load
RB 029 Holland (frtw) 302.1 L W D Allows FRTW for projections
RB 030 NFSA 302.1 N N N Reductions in fire resistance rating where sprinklers are present - cite Super Storm Sandy
RB 031 MACS 302.1 M S A Adds ACI/TMS 216.1
RB 032 CO Code Consulting 302.1 M S A Adds compliance via IBC Chapter 7 which includes ACI/TMS 216.1
RB 033 GBH 302.1 N N N Exterior fire protection - editorial
RB 034 R. Davidson 302.1 N N N Clarifies (badly) that detached garages must also meet ext. wall requirements
RB 035 IAFF 302.1 L W A Protection of projections
RB 036 S NV ICC 302.1.1 H O D Allows reduction in fire separation distance up to 4" for unprotected wall coverings. Could be approve as
RB 037 OR BOA 302.1 N N N Clarifies individual dwelling units
RB 038 R. Davidson 302.2 M O D Removes 2-hr wall where sprinklers not required
RB 039 R. Davidson 302.1 L W A Removes over reaching sprinkler trade-off
RB 040 BCAC 302.1 N N N Common wall compliance
RB 041 San Diego 302.2 N N N Electrical installation in common walls
RB 042 San Diego 302.2 L W A Common wall to party wall
RB 043 San Diego 202 M S A Continuity of common walls
RB 044 CO Code Consulting 302.2 M S AM Two separate 1-hour walls - needs to add structural stable two- hour wall
RB 045 R. Davidson 3022.2. M O D Allows FRTW for parapets
RB 046 R. Davidson 302.2.2 N N N Removes location of penetrations near common walls
RB 047 R. Davidson 302.2.2 M O D Removes parapets
RB 048 R. Davidson 302.2 M O D Removes structural integrity
RB 049 San Diego 302.2 M S A Common wall structural stability
RB 050 R. Davidson 302.3 M O D Reduces fire protection from 1 hr to 1/2 hour
RB 051 IRC Sprinkler coalition
302.2 L W D Public way or yards and sprinklers
RB 052 CO Code Consulting 302.3 H O D Seems to reduce 2-hr to 1-hr, also would benefit by adding ACI/TMS 216.1
RB 053 R. Davidson 302.4 L W D Penetrations - no protection where sprinklered
RB 054 Roberts 302.4.2 N N N Membrane penetrations - protection at luminaires
RB 055 County of Warren, VA
302.5.1 N N N Garage-dwelling door - door and frame criteria
RB 056 R. Davidson 302.5.1 N N N Garage-dwelling door - removes self-closers from criteria
RB 057 Bedford, NH 302.6 N N N Garage-dwelling door - changes to habitable spaces
RB 058 B. Davidson 302.5 N N N Garage-dwelling door - automatic closers
RB 059 Georgia Pacific Gypsum
302.6 N N N Increases use of Type X - Garage separation
RB 060 R. Davidson 302.7 M W D Understair protection - no criteria where sprinklered
RB 061 R. Davidson 302.9 M W D Flame spread - no criteria where sprinklered
RB 062 GBH 302.10.1 M W A Insulation - adds stringency to testing
RB 063 R. Davidson 302.11 M W D Fire blocking - excluded where sprinklered
RB 064 R. Davidson 302.12 M W D Draft stopping - removes all criteria
RB 065 R. Davidson 302.13 N N N Floor fire protection - editorial and excludes decks
RB 066 R. Davidson 302.13 L W A Floor fire protection - adds stairs
RB 067 R. Davidson 302.13 L W D Floor fire protection - adds exemptions
RB 068 National Propane Gas Association
302.13 M W D Floor fire protection - excludes floors over fuel fired appliances
RB 069 Structural Building Components Assoc
302.13 M W A Floor fire protection - dimensional wood
RB 070 Scottsdale 303.3 N N N Exhaust - bathrooms
RB 071 R. Davidson 303.4 N N N Mechanical ventilation - alterations
RB 072 Moore (newportventures)
303.4 N N N Mechanical ventilation
RB 073 R. Davidson 304.1 N N N Minimum room areas
RB 074 R. Daivdson 305.1 N N N Ceiling heights - bathrooms
RB 075 R. Davidson 303.5.1 N N N Mechanical intake - locations
RB 076 R. Davidson 305.1 L W A Min. basement ceiling of 7 ft regardless of habitable. Increase from 6'-8"
RB 077 R. Davidson 306.2 N N N Kitchen - sinks
RB 078 R. Davidson 308.4.2 N N N Glazing - adjacent to doors
RB 079 Thomas (coloradocode)
308.4.2 N N N Glazing - location respect to walls
RB 080 R. Davidson 308.4.3 N N N Glazing - hazard location areas
RB 081 WABO 308.4.4.1 N N N Glazing - adds structural glass baluster panels
RB 082 BCAC 308.4.7 N N N Glazing - hazard location areas
RB 083 R. Davidson 308.1 N N N Glazing - labels in hazard locations
RB 084 R. Davidson 309.1 H O D Garage and carport floor surfaces - permits asphalt in garages
RB 085 R. Davidson 309.4 N N N Garage door openers
RB 086 R. Davidson 310.1 N N N Emergency escapes - limits to sleeping rooms and removes exception for mechanical, stormshelters
RB 087 R. Davidson 310.1 N N N Emergency escape - separation distance
RB 088 R. Davidson 310.1 N N N Emergency escapes eliminated due to sprinklers
RB 089 Shapiro 310.1 N N N Emergency escapes - exceptions
RB 090 R. Davidson 310.1.1 N N N Emergency escapes - hardware
RB 091 BCAC 310.1.1 N N N Emergency escapes - editorial
RB 092 R. Davidson 310.2.1 N N N Emergency escapes - compliance
RB 093 IBHS 310.5 N N N Exempts hurricane protection from means of escape
RB 094 R. Davidson 310.2.1 N N N Emergency escapes - openings
RB 095 ICC Tri-chapter 310.2.3.3 N N N Fall protection - window wells
RB 096 CO Chapter ICC 310.3 N N N Emergency escapes
RB 097 R. Davidson 311.1 N N N Adds paths of travel to means of egress
RB 098 R. Davidson 311.3 N N N Landings - exterior door
RB 099 R. Davidson 311.6 N N N Hallway - width
RB 100 R. Davidson 311.7 N N N Stairs - exceptions to attics and crawlspaces
RB 101 Stairbuilders and Manufacturers
311.7.1 N N N Stairs - width
RB 102 R. Davidson 311.7.1 N N N Stairs - width
RB 103 S NV ICC 311.7.3 N N N Stairs - flight dimensions
RB 104 Stairbuilders and Manufacturers
311.7.4 N N N Stairs - walkline
RB 105 Stairbuilders and Manufacturers
311.7.5.3 N N N Stairs - dimensions
RB 106 Stairbuilders and Manufacturers
311.7.6 N N N Stairs - landings
RB 107 Stairbuilders and Manufacturers
311.7.8 N N N Stairs - handrails
RB 108 Stairbuilders and Manufacturers
311.7.8.2 N N N Stairs - handrails
RB 109 Stairbuilders and Manufacturers
311.7.8.2 N N N Stairs - handrails
RB 110 Stairbuilders and Manufacturers
312.1.2 N N N Stairs - nosing
RB 111 R. Davidson 311.7.11 N N N Stairs - tread devices
RB 112 Bellevue 311.7.11 N N N Stairs - tread devices
RB 113 San Diego 311.7.13 N N N Exterior stairways and ramps
RB 114 Chesterfield Cty VA, American Deck and
311.8 N N N Ramps
RB 115 R. Davidson 311.8.1 N N N Ramps
RB 116 R. Davidson 312.1.1 N N N Fall protection
RB 117 R. Davidson 312.1.1 N N N Fall protection
RB 118 NH BOA 312.1.1 N N N Fall protection
RB 119 Stairbuilders and Manufacturers
311.7.10.1 N N N Spiral stairs
RB 120 R. Davidson 312.1.3 N N N Fall protection
RB 121 Canandaiqua 312.1.5 N N N Cable guard fall protection
RB 122 R. Davidson 312.2 N N N Window fall protection
RB 123 R. Davidson 312.2.1 N N N Window fall protection
RB 124 R. Davidson 313.1 N N N Automatic sprinklers for additions
RB 125 R. Davidson 313.1 M W AM No automatic sprinklers for Type II-A and Type V-A construction - omits Type 1-A and Type III-A
RB 126 R. Davidson 313.1 L MS AM Moves automatic sprinklers to appendix - impact on relaxed passive
RB 127 Johnson 313.2 L MS AM Limits automatic sprinklers to two-family - impact on relaxed passive
RB 128 Johnson 313.2 L MS AM Limits automatic sprinklers to two-family - impact on relaxed passive
RB 129 Gulf Coast Region IX 313.1 L MS AM Moves automatic sprinklers to appendix - impact on relaxed passive
RB 130 R. Davidson 314.2.2 N N N Smoke alarms - alterations
RB 131 OR BOA 314.4 N N N Smoke alarms - interconnection
RB 132 S NV ICC 314.2.2 N N N Smoke alarms - alterations
RB 133 NYS Fire Marshals 314.3 N N N Smoke alarms - location
RB 134 County of Warren VA
314.3 N N N Smoke alarms - location
RB 135 R. Davidson 314.4 N N N Smoke alarms - clarification
RB 136 Automatic Fire Alarm Assoc
314.5 N N N Fire detectors - sprinkler activation
RB 137 R. Davidson 314.7.3 N N N Fire detectors
RB 138 R. Davidson 315.2.1 N N N CO detectors
RB 139 S NV ICC 315.2.2 N N N CO detectors - Roofing and siding alterations
RB 140 S NV ICC 315.2.2 N N N CO Detectors - fuel fired mechanical replacement
RB 141 R. Davidson 315.3 N N N CO detectors
RB 142 WA State BCC 315.3 N N N CO detectors
RB 143 R. Davidson 315.5 N N N CO detectors
RB 144 S NV ICC 315.5 N N N CO detectors
RB 145 R. Davidson 315.6.3 N N N CO detectors
RB 146 Roberts-UL 316.3 N N N Editorial clarification on surface burning
RB 147 GBH 316.4 N N N Removes wood structural panel and adds heavy timber as thermal barrier
RB 148 R. Davidson 316.5.3 N N N Attic access thermal barrier removed
RB 149 R. Davidson 316.5.4 N N N Crawl space openings
RB 150 James Hardie 316.5.4 L W A Adds cement fiber board as barrier protection
RB 151 R. Davidson 316.5.11 N N N Rigid or sprayed foam plastic insulation
RB 152 Green Science Policy Institute
316.5.14 M O D No fire protection for below grade foam
RB 153 Altamonte Springs 316.6 H O D Allows combustible fro fire protection of combustible foam sheathing
RB 154 AWC 317.1 N N N Wood treatment
RB 155 Engineered Wood Association
317.1.5 L W A Expands pressure treated wood from exposed glue laminated to all wood members
RB 156 R. Davidson 320.1 N N N Removes accessibility scope and guestrooms
RB 157 FEMA 301.2.4 L W A Flood - increased stringency for V and Coastal A - requires ASCE 24
RB 158 FEMA 301.2.4.1 L W A Flood - ASCE 24 as alternative provisions
RB 159 FEMA 322.3.3 L W A Flood - Columns and piles
RB 160 FEMA 322.3.3 L W A Flood - Concrete slabs
RB 161 FEMA 322.3.6 L W A Flood - Stairways and ramps
RB 162 FEMA 322.3.6 L W A Flood - Decks
RB 163 R. Davidson 163 H O D Moves storm shelters to appendix
RB 164 SEIA 324.3 N N N Photovoltaic - revisions with fire classifications
RB 165 Seattle 324.1.1 N N N Photovoltaic - dead load
RB 166 BCAC 325.1 H O D Habitable attics - not a story
RB 167 Seattle 325.3 L W N Mezzanine area increases
RB 168 R. Davidson 327 N N N Small houses exceptions
RB 169 GBH 327 N N N Stationary generators
RB 170 BCAC 327 N N N Vehicular gates
RB 171 BCAC 327.1 N N N Energy storage systems (ESS - Batteries) installed per NFPA 70
RB 172 GeoCoalition 401.4 N N N Collected roof water disposal
RB 173 Superior Walls 401.2 L W N Precast concrete foundations - editorial
RB 174 R. Davidson 401.3 N N N Surface drainage collection
RB 175 S NV ICC 401.3 N N N Surface drainage swales
RB 176 Superior Walls 403.1.1 L W N Precast concrete foundations - gravel footings
RB 177 AISI 403.1.6 N N N Cold-formed steel sill plates
RB 178 Superior Walls 403.4 L W N Precast concrete foundations - footing width
RB 179 Extruded Polystyrene Foam
403.3 N N N Updates insulation R-values for FPSF
RB 180 Superior Walls 403.4 L W N Precast concrete foundations - gravel footing
RB 181 Superior Walls 403.4 L W N Precast concrete foundations - footing sill plate
RB 182 Josh O'Conner 404.1.1.1 L W D Increases pass through width but limited to concrete and masonry walls
RB 183 R. Davidson 405.1 N N N Allows sump in addition to open drainage for foundation
RB 184 County of Warren VA
405.1 N N N Adds option for drainage tile bottom of slab
RB 185 East Greenwich 408.3 N N N Crawl space ventilation
RB 186 Conner 408.3 N N N Crawl space ventilation
RB 187 Conner 408.3 N N N Crawl spaces dehumidification
RB 188 R. Davidson 408.4 N N N Attic and crawlspace access
RB 189 Engineered Wood Association
502.1.3 N N N Adds ANSI 117 for structural glue laminated timber
RB 190 NCSEA 301.5 M S A Balcony load increases
RB 191 R. Davidson 305.1 L W A Habitable attic loads
RB 192 R. Davidson 502.6 N N N Beam, girder, or joist bearing
RB 193 R. Davidson 502.11.2 N N N Truss bracing
RB 194 R. Davidson 502.11.4 N N N Truss design drawings
RB 195 AISI 505.1.1 N N N Cold-formed steel updates
RB 196 R. Davidson 506.2.3 L O D Removes requirement for vapor barrier for slab on ground
RB 197 S NV ICC 506.2.3 N N N Sub-slab vapor retarder for 6 mil to 10 mil
RB 198 Chesterfield Cty VA, American Deck and
507.3.5 N N N Revision of entire section on exterior decks
RB 199 Chesterfield Cty VA, American Deck and
507.3.5 N N N Revision of entire section on light framed wood decks
RB 200 Chesterfield Cty VA, American Deck and
507.5.1(2) N N N Deck connections
RB 201 Chesterfield Cty VA, American Deck and
507.1 N N N Freestanding decks
RB 202 Chesterfield Cty VA, American Deck and
507.3.5 N N N Alternative deck railing materials
RB 203 Chesterfield Cty VA, American Deck and
507 N N N Deck attachment
RB 204 OR BOA 507.2.3 N N N Deck fasteners
RB 205 Chesterfield Cty VA, American Deck and
507.3 N N N Decks on ground
RB 206 Chesterfield Cty VA, American Deck and
507.3 N N N Deck supports
RB 207 Chesterfield Cty VA, American Deck and
507.3 N N N Deck footing sizes
RB 208 Chesterfield Cty VA, American Deck and
507.3 N N N Deck footing sizes
RB 209 Chesterfield Cty VA, American Deck and
507.4 N N N Deck board fasteners
RB 210 Chesterfield Cty VA, American Deck and
507.5 N N N Deck joists
RB 211 Chesterfield Cty VA, American Deck and
507.8 N N N Deck posts and deck attachment
RB 212 Chesterfield Cty VA, American Deck and
507.8 N N N Deck posts
RB 213 Chesterfield Cty VA, American Deck and
507.8 N N N Deck posts
RB 214 Chesterfield Cty VA, American Deck and
507.8 N N N Posts bearing on gravel
RB 215 Rock Island, IL 507.8.1 N N N Eliminates wood posts embedded in concrete
RB 216 R. Davidson 601.2.1 N N N Compressible floor coverings
RB 217 Engineered Wood Association
602.1.11 N N N ANSI APA structural insulated wall panel standard
RB 218 NAHB 602.3(6) N N N New prescriptive table for 10 foot wood stud walls
RB 219 AWC 602.10.3 N N N Roof sheathing nailing corrections
RB 220 AWC 602.3 N N N Roof sheathing rink shanks
RB 221 Smith (AWC) 602.3 N N N Structural panel sheathing cantilever
RB 222 S mith (AWC) 602.3 N N N Clarifies nail spacing footnote
RB 223 Engineered Wood Association
602.3.2 N N N Adds lumber splice option
RB 224 James City, VA 602.5 N N N Overlapping of double wood plates
RB 225 County of Warren VA
602.7 N N N Allows interpolation of girder span values
RB 226 AWC 602.7 N N N Updates girder spans for soft wood
RB 227 AWC 602.7 N N N Updates girder spans for soft wood
RB 228 AWC 602.7.2 N N N Revises figure on joist hangers
RB 229 AWC 602.7.5 N N N Simplifies full height wood stud table
RB 230 VBOCA 602.10.10 N N N Revisions for braced wall panels
RB 231 VBOCA 602 N N N Revises wall bracing adjustment factor
RB 232 Engineered Wood Association
602.10.3 N N N Revises clarifying ABW, PFH, and PFG bracing requirements
RB 233 Engineered Wood Association
602.10.3 N N N Revises bracing requirement footnotes
RB 234 Engineered Wood Association
602.10.3 N N N Updates in length of wall bracing changes from wall height to story height
RB 235 Engineered Wood Association
602.10.3 N N N Footnote clarifying use of ABW, PFH, and PFG braced frames in seismic
RB 236 Engineered Wood Association
602.10.3 N N N Corrects error from wording change last cycle on wall bracing
RB 237 Engineered Wood Association
602.10.3 N N N Corrects error from wording change last cycle on wall bracing
RB 238 Structural Building Components Assoc
602.10.3 N N N Adds note on development of braced wall panel lengths
RB 239 WJE, FEMA, BSSC 602.10.3 M W A Alternative means for attaching 2nd story veneer
RB 240 AWC 602.10.4 N N N Removes 8d nails as fasteners for structural fiberboard sheathing
RB 241 Engineered Wood Association
602.10.5 N N N Reorganizes wood portal frame criteria
RB 242 Engineered Wood Association
602.10.5.2 N N N Revises partial credit for intermittent bracing in wood walls
RB 243 Engineered Wood Association
602.10.10 N N N Updates wood portal frame criteria
RB 244 Engineered Wood Association
602.10.10 N N N Adds criteria for continuously sheathed walls
RB 245 Engineered Wood Association
602.10.10 N N N Adds criteria for continuously sheathed walls
RB 246 Engineered Wood Association
602.10.6.6 N N N Adds new criteria for continuously sheathed walls
RB 247 Engineered Wood Association
602.10.10 N N N Adds criteria for continuously sheathed walls
RB 248 AISI 603.1.1 N N N Updates cold-formed steel criteria
RB 249 MACS 606.1 L W A Adds TMS 404 for cast stone
RB 250 MACS 607 N N N Restores adobe criteria
RB 251 Thomas Bren Homes
609.1 N N N Window and doors drainage to pan flashing
RB 252 American Chemistry Council
609.1 N N N Window and door installation and flashing
RB 253 Window and Door Manufacturers
609.1 N N N Window and door anchorage
RB 254 Window and Door Manufacturers
609.2 N N N Window and door testing at 0.6 ASCE 7 load
RB 255 IBHS 609.2 N N N Windows and doors permanent labeling
RB 256 R. Davidson 609.4 N N N Garage door criteria where wind exceeds 115 mph
RB 257 I BHS 609.4 N N N Garage door labeling
RB 258 Neumann Sloat Blanco Architects
609.5 N N N Window and door testing
RB 259 IBHS 609.6.2 N N N Window and door wind debris impact protection
RB 260 FL Lath & Plaster Bureau
702.2.1 N N N Adds ASTM C841 and C842 for gypsum plaster
RB 261 FL Lath & Plaster Bureau
702.2 N N N Clarifies material and installation ref. std for stucco
RB 262 FL Lath & Plaster Bureau
702.1 N W N Removes prescription for gypsum stucco in favor of ASTM C843
RB 263 FL Lath & Plaster Bureau
702.1 JF JF JF Removes prescription for cement stucco in favor of ASTM C926
RB 264 Gypsum Assoc 702.3.1 N N N Adds C1766 for factory laminated gypsum board
RB 265 AISI 702.3.3 N N N Updates cold-formed steel to AISI S240-15
RB 266 Engineered Wood Association
702.7 N N N Revision of vapor retarders for wood frame
RB 267 American Chemistry Council
702.7 N N N Revision of vapor retarders for wood frame
RB 268 NAHB 702.7 N N N Revision of vapor retarder for wood frame
RB 269 Energy Logic 702.7 N N N Requires vapor retarders in Zones 1, 2, 3, and non-marine 4
RB 270 Energy Logic 702.7 N N N Adds vented cladding to Class III vapor retarder in zones 6,5, and Marine 4. Removes criteria for Dry
RB 271 I
Energy Logic 702.8 N N N Document vapor management strategies
RB 271 II
Energy Logic 702.8 N N N Test ventilation systems
RB 272 Conner 702.7.1 N N N Removes climate zone 8 criteria for class III vapor retarders
RB 273 American Chemistry Council
702.7.1 N N N Increases continuous insulation values for Zones 7 and 8
RB 274 Structural Building Components Assoc
702.7.1 N N N Limits wood structural panel to plywood in Marine 5
RB 275 NAHB 702.7.2 N N N Latex and enamel perm rating per manufacturer
RB 276 Vinyl Siding Inst. 702.7.3 N N N Adds polypropylene to list of vented cladding
RB 277 American Chemistry Council
702.7.4 N N N Wet applied insulation in wall cavities
RB 278 Building Professionals
703.1.1 N N N Drainage from veneer to cladding but exception for masonry remains
RB 279 Bldg Enclosure Moisture Mgmt
703.1.1 N N N Drainage from veneer to cladding but exception for masonry remains
RB 280 Engineered Wood Association
703.1.1 N N N Changes drainage from veneer to all cladding but exception for masonry remains
RB 281 Vinyl Siding Inst. 703.1.1.1 L W AM Drainage for all cladding. Seems to presumes all cladding over frame construction - Maybe a floor
RB 282 FEMA 703.1.2 N N N Adds soffits into wind analysis
RB 283 American Chemistry Council
703.2 N N N Adds other water-penetration resistance systems
RB 284 Ursenbach 703.2 N N N Requires water resistance for accessory buildings
RB 285 Dupont 703.2 N N N Adds other water-penetration resistance systems including Grade D paper
RB 286 American Chemistry Council
703.2.1 N N N Adds other water-penetration resistance systems
RB 287 American Chemistry Council
703.4 N N N Reorganizes flashing criteria
RB 288 GBH 703.4 L W D Flash all penetrations
RB 289 Dupont 703.4 N N N Clarifies scoping on flashing
RB 290 In-Spex 703.7.1 JF JF JF Removes prescription on stucco and replaces with ASTM C1063
RB 291 American Chemistry Council
703.6.1 N N N Allows woods shakes over foam sheathing
RB 292 In-Spex, FL Lath & Plaster Bureau
703.7.2 JF JF JF Appear to eliminate stucco on lath
RB 293 In-Spex 703.7.2.1 JF JF JF Stucco weep screeds
RB 294 In-spex 703.7.5 JF JF JF Stucco curing
RB 295 BCAC 702.1 JF JF JF Coordinates stucco criteria with ASTM standards
RB 296 PCA 702.1 L S A Adds C1157 cement for stucco
RB 297 American Chemistry Council
703.7.1 L W A Revises stucco lath attachment
RB 298 American Chemistry Council
703.7.3 N N N Clarifies criteria on water barriers
RB 299 American Chemistry Council
703.7.3 JF JF JF Ventilated airspace behind stucco
RB 300 Building Professionals
703.7.3 N N N Provides option to eliminate drainage space where water barrier material complies with ASTM E2925
RB 301 Building Professionals
703.7.3 N N N Adds ASTM E2556 for water barrier over wood
RB 302 Dupont 703.7.3 N N N Adds ASTM E2556 for water barrier over wood
RB 303 APA, Engineered Wood Products
703.8.4 M S A Brick veneer ties to structural sheathing
RB 304 WABO 703.10.2 N N N Fiber cement siding butt joints
RB 305 Amer. Chemistry Council
703.11.2 L O D Attachment of vinyl siding through foam sheathing
RB 306 AWC 703.11.2 M W A Sheathing attachment upgrade for new wind criteria
RB 307 GBH 703.14 L W A Places additional restrictions on polypropylene foam sheathing
RB 308 Amer. Chemistry Council
703.15.1 N N N Rounds fastener table numbers to nearest 0.05 in.
RB 309 Amer. Chemistry Council
703.16.1 ? ? ? Fastening cladding through wall foam sheathing
RB 310 Chesterfield Cty VA 802 N N N Separates criteria for roof ridge, rafters, and ceiling joists
RB 311 GBH 802.1.5 M W A Adds criteria for FRTW
RB 312 Hoover Treated Wood Products
802.1.5.2 N N N Prohibits coating FRTW
RB 313 GBH 802.1.5.3 L O D Removes option for testing FRTW
RB 314 Holland 802.1.5.4 L W A Labeling of FRTW
RB 315 APA, Engineered Wood Assoc
802.1.8 N N N Prefabricated wood joists in accordance with ASTM D5055
RB 316 R. Davidson 802.10.1 N N N Truss drawing criteria
RB 317 Kerr 802.10.1 N N N Align truss drawing criteria with IBC
RB 318 R. Davidson 802.3.1 N N N Joist/rafter connection clarifications
RB 319 AWC 802.5.1 N N N Rafter joist heel connection
RB 320 R. Davidson 802.9 N N N Removes conflicting language on roof framing member bearing
RB 321 AISI 804.1.1 N N N Cold-formed steel roof framing update
RB 322 ARMA 806.1 N N N Balanced attic ventilation area
RB 323 ARMA 806.1 N N N Aligns with IBC on attic ventilation
RB 324 ARMA 806.2 N N N Clarification for attic vent area
RB 325 S NV ICC 806.2 N N N Min. attic ventilation area
RB 326 Conner 806.5 N N N Moisture in unvented attics and rafter areas
RB 327 Conner, Lstiburek 806.5 N N N Moisture in unvented attics
RB 328 Lstiburek 806.5 N N N Attic ventilation
RB 329 NAIMA 806.5 N N N Unvented attic insulation
RB 330 R. Davidson 807.1 N N N Removes attic access criteria in favor of IMC
RB 331 R. Davidson 807.1 L W A Attic access for combustible materials
RB 332 S NV ICC 807.1 N N N Exception - No attic access required where no equipment
RB 333 MAIA (Atlanta Inspectors)
807.1.1 N N N Requires pull down stairs for attic with equipment
RB 334 R. Davidson 902.2 N N N Removes all criteria for Fire retardant wood shakes for roofs
RB 335 AWC 902.2 N N N Removes inappropriate ref std for roof wood shakes - but still does not provide criteria
RB 336 SEIA 902.4 N N N Photovoltaic panel flame spread
RB 337 SEIA 902.1 N N N Photovoltaic panel flame spread
RB 338 SEIA 902.4 N N N Rooftop photovoltaics
RB 339 Roberts 902.4 N N N Roof photovoltaics - adds UL 2703
RB 340 IBHS, FEMA 903.4.2 N N N Roof gutter attachment
RB 341 IBHS 905.1.1 N N N Roof underlayment criteria
RB 342 IBHS 905.1 N N N Roof underlayment criteria
RB 343 IBHS 905.1.1 N N N Roof underlayment lapping
RB 344 RCMA 905.15.3 N N N Editorially adds "approved installation" for liquid applied roof materials
RB 345 NRCA 905.11.2 N N N Removes obsolete ASTM roof standard
RB 346 ISNTA 905.16.4.2 N N N Roof underlayment attachment
RB 347 R. Davidson 905.2.8 N N N Adds roof drip edge criteria
RB 348 R. Davidson 905.2.8 N N N No drip edge required for re-roofing
RB 349 R. Davidson 905.2.8 N N N Roof drip edge limitations
RB 350 IBHS 905.8.2 L W A Limits use of wood shakes on roofs based on higher pitch
RB 351 Intech, Dow Chemical
905.17 N N N Roof integrated photovoltaic panels
RB 352 ROXUL 906.2 L W A Adds mineral wool roof insulation - possible ally on future NFPA 285 issues
RB 353 IBHS 907.1 M W A Align height for eave and gables with aSCE 7-16 wind
RB 354 WABO 907.2 N N N Wind load for photovoltaics
RB 355 R. Davidson 908 N N N Makes re-roofing an appendix in lieu of section of the code
RB 356 R. Davidson 908.1 N N N No ice-barrier for roof recover
RB 357 WABO 909.2 N N N Rooftop photovoltaics
RB 358 AMnBO 101.1 N N N Editorial tracking language
RB 359 Hearth and Homes T R1005.8 N N N Insulation shield on factory built chimneys
RB 360 FEMA AE101.1 N N N Adds manufactured home criteria for flood plans
RB 361 Koch R327 N N N Adds radon control methods to body of code
RB 362 Amer Assoc of Radon Scientists
AF101 N N N Revises radon control
RB 363 AMnBO AK101/R32 M W A Adds sound transmission back into body of code
RB 364 WABO AK101 N N N Editorial on sound transmission
RB 365 Design Coalition, StrawClay,
AR101 N N N Revises straw bale appendix
RB 366 Hammer, Eisenburg-DCAT, Santa Clara
AS101.1 N N N Revises straw bale appendix
RB 367 Hammer, Eisenburg-DCAT
AS102.1 N N N Adds straw bale details and revises criteria
RB 368 Hammer, Eisenburg-DCAT
AS1072.1 N N N Revises straw bale appendix
RB 369 GBH AS107.1 N N N Adds fire resistance criteria for straw bale construction
RB 370 GBH AS107.1 N N N Adds criteria for straw bale construction
RB 371 Seattle U103 N N N Solar panel ready roofs
RB 372 WJE, FEMA, BSSC AV101 L W D Seismic repair and retrofit of masonry chimneys - no masonry solution apparent
RB 373 American Chemistry AV101 mvg mvg mvg Alternative R-Values for above grade wood frame walls - Check validity of c.i. values
RB 374 Broan-Nu-Tone M1507.1 N N N Mechanical ventilation
RB 375 Broan-Nu-Tone M1503.1 N N N Mechanical ventilation
*** END OF SECTION IRC - RESIDENTIAL ***
Desi
red
Com
mitt
ee
Asse
mbl
y
Desi
red
Asse
mbl
y
W 001 PCA 504.5 W W Duplicate
W 002 PCA 504.5 M AM AM Removes log home and heavy timber. Needs modification
W 003 AWC 504.5 H O D Permits assemblies passing ASTM E2707 test
W 004 AWC 504.7 N N N Appendages and projections, Class 1
W 005 Kellen 504.7 N N N Appendages and projections, Class 1 and 2
W 006 AWC 505.5 M W D Exterior walls, Class 2
W 007 AWC 505.7 N N N Appendages and projections, Class 2
W 008 Hoover Treated 506.3 N N N Underfloor enclosure, Class 3
W 009 AWC (NEW) IWU M O D California standards
*** END OF SECTION IWUIC - WILDLAND-URBAN INTERFACE ***
IWUIC - WILDLAND-URBAN INTERFACEImpact: H=High, M=Moderate, L=Low, N=None
Position: O=Oppose, S=Support, MO=Mild Opposition, MS=Mild Support, N = NoneAction: A=Approve, D=Disapprove, AM=Approve as Modified, W=Withdrawn
Desi
gnat
ion
Num
ber Proponent
Sect
ion
Impa
ct
PCA
Posi
tion
Committee Action
Publ
ic C
omm
ent Public
Comment
Fina
l Act
ion
Concept