M2000 R009 System Overview &
Troubleshooting
Brought to you by AJI 22 September 2010
Overview
iManager M2000 Mobile Element Management System
(EMS M2000) is the centralized management platform
for Huawei mobile network.
iManager M2000 includes client and server.
This presentation will be focus on the newest version of
M2000 (R009) in Fault, Performance, and
Configuration sides.
Chapter 1 Introduction With M2000 Chapter 1 Introduction With M2000
R009R009
Chapter 2 M2000 Basic FeatureChapter 2 M2000 Basic Feature
Chapter 3 M2000 TroubleshootingChapter 3 M2000 Troubleshooting
Network Position of iManager M2000
Physical Structure and Software Architecture M2000
• Chapter 1 Introduction With M2000 Chapter 1 Introduction With M2000
• Chapter 2 M2000 Basic FeatureChapter 2 M2000 Basic Feature
• Chapter 3 M2000 Troubleshooting Chapter 3 M2000 Troubleshooting
CConfiguration Managementonfiguration ManagementFFault Managementault Management
SSecurity Managementecurity ManagementPPerformance Managementerformance Management
TTopology Managementopology Management
M2000 BASIC FEATURES
Topology ManagementTopology Management
• Create Physical NE
• Managing Topology Data
• Monitoring NEs
• Modifying Network Topology Views
• Setting Up a Physical Topology View
Alarm List and Alarm Log Concepts
• Current Alarm: including uncleared and unacknowledged, uncleared and acknowledged, cleared and unacknowledged.
• Alarm List: Alarm managers mainly focus on the Alarm list, the alarms are summed up.
• History Alarm: providing long term alarm store and query; including cleared and acknowledged alarms
• Alarm Log: providing alarm query, on all the alarms collected, which works as the sum of current alarm and history alarms;
Current
Alarm
Alarm ListAlarm List
History Alarm
Alarm logAlarm lognew
new
(Alarm List) Cont’d
Procedure of Performance Huawei M2000 System
mrf.zip file
PM Service (Provides the function of equipment result data storage and analyze management)
Sybase (Ex ample, Use Sybase Central)
PMExport (Export Data from database to file, provides the function of file interface) pmexport_2010xxxx files
M2000 Client
PM Service
NE (Network Element)
• Chapter 1 Introduction With M2000 Chapter 1 Introduction With M2000
• Chapter 2 M2000 Basic FeatureChapter 2 M2000 Basic Feature
• Chapter 3 M2000 Troubleshooting Chapter 3 M2000 Troubleshooting
Performance Management
• Incomplete Data1. Synchronization
2. Retrieve
Add User Defined Counters Management
1. Create user Defined 2. Create Template
Performance Management
3. Create Task Performance Data Export
Alarm Management
• Warning should be Critical ?
Alarm Management
The tab name is changed from Severity Redefine to Redefine
Three columns are added: Type, Redefined Name, Redefined Severity, Redefined Type.
Alarm Redefinition
Alarm Redefinition
Original Setting panel displays the alarm settings before redefinition.
Original Setting panel displays the alarm settings before redefinition.
Redefined Setting panel offers the Name, Type and Severity for redefinition.
Redefined Setting panel offers the Name, Type and Severity for redefinition.
Remember to Enable the
redefinition rule.
Remember to Enable the
redefinition rule.
Firstly click Add to open the
dialog window.Firstly click Add to open the
dialog window.
SMS 507 Problem
• Invalide Alarm Names ?
SMS 507 Problem
• Adding AlarmID to script • Example : List alarmID in script put in “input.txt” as input item in script updateAlarm.sh
• AlarmID=2402, AlarmName="DC Fan Alarm"• AlarmID=2404, AlarmName="Rectifier DC Low or High Voltage"• AlarmID=2406, AlarmName="Rectifier module fault alarm"• AlarmID=2408, AlarmName="Medium surge protections failure MSPF"• AlarmID=2410, AlarmName="AC L1 failure alarm PLN"• AlarmID=2412, AlarmName="AC L2 failure alarm PLN"• AlarmID=2414, AlarmName="AC L3 failure alarm PLN"• AlarmID=2416, AlarmName="Fence break or Grounding cut or Air condition removed"• AlarmID=2418, AlarmName="Genset run alarm"• AlarmID=2420, AlarmName="Genset failure alarm"• AlarmID=6438, AlarmName="DC Fan Alarm"• AlarmID=6440, AlarmName="Rectifier DC Low or High Voltage"• AlarmID=6442, AlarmName="Rectifier module fault alarm"• AlarmID=6444, AlarmName="Medium surge protections failure MSPF"• AlarmID=6446, AlarmName="AC L1 failure alarm PLN"• AlarmID=6448, AlarmName="AC L2 failure alarm PLN"• AlarmID=6450, AlarmName="AC L3 failure alarm PLN"• AlarmID=6452, AlarmName="Fence break or Grounding cut or Air condition removed"• AlarmID=6454, AlarmName="Genset run alarm"• AlarmID=6456, AlarmName="Genset failure alarm"
Configuration Management
1. Create Task
Result of Task