1
INTRODUCING: THE YORK® YZ CHILLER
Water-cooled magnetic bearing centrifugal chiller165 through 1350 Tons (581 through 4747 kW)
The Future. Today.
3 YZ CENTRIFUGAL CHILLER
YORK® YZ Magnetic Bearing Centrifugal Chiller
From the Chiller Experts
Optimized for Ultimate Performance
Dramatically Lower Cost of Ownership
The New Definition of Sustainability
From the Chiller Experts
5
From the Chiller Experts
YZ CENTRIFUGAL CHILLER
Sight Glass
Variable Speed Drive- Four decades of proven
VSD chillers- VSD is standard on YZ
Low-Pressure Chiller- YORK® has a history of low-
pressure refrigerant chillers to deliver high-efficiency
- YZ is designed to maximize the efficiency of a low GWP refrigerant
- Advanced, single-stage design enables YZ to provide the highest real-world energy efficiency
Optimized Compressor
Magnetic-Bearing Driveline- In 1998, YORK® Navy Systems
pioneered reliable magnetic-bearing technology to cool submarines
- The same durable and efficient technology is used on the YZ
Falling Film Evaporator- Patented design- Reduces refrigerant
charge up to 60%
6
Advanced Aerodynamic System
• Single-Stage Compressor• Exceptional part load performance• Wide operating map• Minimized operating expenses
• Patented VGD Capacity Control• Rapid response to building load changes
• Optimized Suction Line• High efficiency design • Fewer moving parts
YZ CENTRIFUGAL CHILLER
7
Induction Motor & Magnetic Bearing Driveline
• Induction motors custom-designed for the compressor speed and torque• High efficiency• Lower complexity VSD technology
• Magnetic bearings• Lubrication free!• Wide speed range• Low maintenance
• Simple, high efficiency, low maintenance driveline!
YZ CENTRIFUGAL CHILLER
8
Variable Speed Drive
• VSD is integral to the design of the YZ
• Allows compressor/motor to run at the exact speed needed based on building load
• Low in-rush current for longer motor life
• Provides highest possible part load efficiency for real-world energy savings at off-design conditions
• Optional active harmonic filter available
YZ CENTRIFUGAL CHILLER
9
Falling Film Evaporator
• Maintains real world operating capabilities
• Minimizes refrigerant charge• Up to 60% reduction compared to low pressure
flooded designs
• Reduces evaporator diameter• Up to 20% reduction compared to low pressure
flooded designs
YZ CENTRIFUGAL CHILLER
10
Low pressure refrigerants ‘unlock’ access to higher efficiency & new technology options
Alternate Refrigerant Options for Centrifugal Chillers
We didn’t invest in a next generation platform just to have low GWP.
We did it for the efficiency benefit.
YZ CENTRIFUGAL CHILLER
Optimized for Ultimate Performance
12
Pushing the Efficiency Frontier
When it comes to efficiency, even among our own world-class designs, the YORK® YZ is the new benchmark for part load values.
YZ CENTRIFUGAL CHILLER
Evolution of Efficiency
13 YZ CENTRIFUGAL CHILLER
More Efficient More Often
Conventional chillers typically can’t operate below 60° F (16° C)
Entering condenser water temperature as low as 40° F (4.5° C)
Full condenser flow at all load points
Efficiencies as low as 0.090 kW/ton or 39 COP!
The operating map can vary, please contact your local sales representative for project specific details
14 YZ CENTRIFUGAL CHILLER
Real-World Efficiency• Superior off-design efficiency
using:• Variable Geometry Diffuser (VGD)• Variable Speed Drive (VSD)• Magnetic Bearing Technology
• Chillers operate in off-design conditions up to 99% of the time
Up to 41% annual energy savings versus traditional fixed-speed oil-bearing chillersUp to 20% savings versus variable-speed oil-bearing chillers
Up to 41% Savings
Initial Cost
Note: AEC done using 700 ton chiller, in a moderate climate (average building load and run hours)
Dramatically Lower Cost of Ownership
16 YZ CENTRIFUGAL CHILLER
Not just oil free…lubrication free!
OIL-LUBRICATED BEARINGS REFRIGERANT-LUBRICATED BALL BEARINGS MAGNETIC BEARINGS
17
Lubrication Free Means Less Maintenance
YZ CENTRIFUGAL CHILLER
Driveline Maintenance Tasks
Oil-lubricated Bearing Competitor
Refrigerant-lubricated Bearing Competitor
Check lubrication eductors
Lubricant analysis
Replace lubricant filter(s)
Vibration analysis
YORK® YZ
Annually
Check lubricant sump & temperature control operation Monthly
Clean refrigerant pump strainer
Battery health test Periodically
Annually
Quarterly
Monthly
Periodically
Annually
Annually
Monthly
Monthly
Monthly
------
-
--
YORK® centrifugals have no scheduled compressor/motor teardown
18 YZ CENTRIFUGAL CHILLER
Reduced Maintenance Costs
• All centrifugal chillers require some amount of scheduled maintenance• Cleaning tubes • Checking refrigerant levels
• The lubrication-free YZ chiller sets itself apart with lifetime savings on driveline maintenance
Motor bearing teardownsFilter changesLubrication system maintenance
We keep more money in your pocket over your chiller’s lifetime!
19
Smart Connected Chiller Services
YZ CENTRIFUGAL CHILLER
Critical alarms sent directly to your local
service provider
Chiller operating data is sent for storage and
analysis
Analytics used to produce Chiller Health Reports,
provided every visit
Operating & trend data accessible anywhere, anytime by our local,
regional and global experts
Connected Chiller Cloud-based Service Platform
Service BranchTechnicianCustomer Facility
Global Chiller Technical Support
20
Smart Connected Chiller Services
Greater UptimeIndustry-leading remote monitoring and cloud-based analysis give 24/7 access to chiller trend data and predictive analytics.
Less time to repair Fewer shutdowns Superior total uptime
YZ CENTRIFUGAL CHILLER
Improvement in Mean Time to Repair
Greater Uptime
72
Aver
age
Hou
rs to
Rep
air
48
24
0
24
OTHER CHILLERS
CONNECTED CHILLERS
21
Dramatically Lower Cost of Ownership
YZ CENTRIFUGAL CHILLER
Over the life of the chiller when compared to a traditional oil-lubricated chiller with a VSD.
Reduced Operating Costs+
Minimized Maintenance costs=
Total savings equivalent to over 4 times the initial chiller
cost!
The New Definition of Sustainability
23 YZ CENTRIFUGAL CHILLER
New Definition of Sustainability
True sustainability means the lowest total emissions – from beginning to end –by designing for the highest possible efficiency.
R-1233zdOptimized
High Efficiency Design
Lowest Total Emissions
24 YZ CENTRIFUGAL CHILLER
The Only Chiller Fully Optimized for True Sustainability
• Total Equivalent Warming Impact (TEWI) = the measurement of a chiller’s direct + indirect emissions• Indirect Emissions - Amount of
energy used by the chiller (based on energy source mix of power generation used to operate the chiller)
• Direct Emissions – determined by impact of possible leak from chiller & GWP of the refrigerant in the chiller (R-1233zd GWP = 1)
• TEWI is a more complete measure of environmental progress
Direct emissions – less than 5% of total greenhouse gas emissions
<
>
Indirect emissions – over 95% of greenhouse gas emissions
25
THE YORK® YZ CHILLERTHE FIRST CHILLER BUILT TO
EXCEED EVERY EXPECTATION –TODAY AND TOMORROW.
Visit YORK.com/Next for more information
YZ CENTRIFUGAL CHILLER
If you can read this Click on the icon to choose a
picture or Reset the slide.
To Reset: Right click on the slide thumbnail and select ‘reset slide’ or
choose the ‘Reset’ button on the ‘Home’ ribbon (next to the font choice
box)
If you can read this Click on the icon to choose a
picture or Reset the slide.
To Reset: Right click on the slide thumbnail and select ‘reset slide’ or
choose the ‘Reset’ button on the ‘Home’ ribbon (next to the font choice
box)
Johnson Controls, Inc. —
45 to 260 kW (13 to 74 tons)Stand Alone/Modular Application
YORK® AMICHITM (YMAA/YMPA) SERIESAir-cooled DC Inverter Scroll Chillers And Heat Pumps
If you can read this Click on the icon to choose a picture or
Reset the slide.To Reset: Right click on the slide thumbnail and select ‘reset slide’ or
choose the ‘Reset’ button on the ‘Home’ ribbon (next to the font choice box)
If you can read this Click on the icon to choose a picture or
Reset the slide.To Reset: Right click on the slide thumbnail and select ‘reset slide’ or
choose the ‘Reset’ button on the ‘Home’ ribbon (next to the font choice box)
Johnson Controls, Inc. —27
State Of The Art
Most Efficient
Compact
Modular/Scalable
Smart Connected
Johnson Controls, Inc. —28
YMAA/YMPA MAIN COMPONENTS
EC Fan
DC Inverter Scroll Fix-speed
Scrolls
Liquid Separator
Patented U-Shaped Condenser Coils
Electronic Expansion Valves
Johnson Controls, Inc. —29
Victaulic couplings
Inverter Drive Compressor
Brazed Plate Heat Exchanger
Optiview LTTMVerasysTM Compatible
Control Panel
YMAA/YMPA MAIN COMPONENTS
Johnson Controls, Inc. —30
EXCEEDING EFFICIENCY STANDARDSTOMORROW’S EFFICIENCY STANDARDS MET TODAY
Eco-designRegulation Category
EfficiencyMetric:
Minimum Efficiency Tier
2:
TOMORROW’S STANDARDS MET TODAY
Comfort HeatingReg. 813/2013
ηshSCOP
125%3.2
Amichi Heat Pump: Sept. 2017 Compliant (Tier 2)SCOP>3.2
Comfort CoolingReg. 2016/2281
ηscSEER
161%4.1
Amichi Chiller: Jan 2021 Compliant (Tier 2)SEER>4.1
Process Cooling (Med. Temp.)Reg. 1095/2015
SEPR 2.58 Amichi Chiller:July 2018 Compliant (Tier 2)SEPR>2.58
Process Cooling (High Temp.)Reg. 2016/2281
SEPR 5.0 Amichi Chiller:Jan 2021 Compliant (Tier 2)SEPR>5.0
Johnson Controls, Inc. —31
EXEDING EFFICIENCY STANDARDSTOMORROW’S EFFICIENCY STANDARDS MET TODAY
Equivalent to Ecodesign 2021 MEP
Equivalent to Ecodesign 2021 MEP
Johnson Controls, Inc. —32
Two sound levels to meet the occupant requirements :
Standard low-noise
Ultra Quiet Kit can further reduce sound power by a 6 dBAaverage
PERFORMANCE WITHOUT COMPROMISEONE OF THE QUIETEST UNITS AVAILABLE
YMAA Sound Area
Johnson Controls, Inc. —33
PERFORMANCE WITHOUT COMPROMISEPERFECT SOLUTION FOR HIGH PERFORMANCE IN SMALLER SPACES
Compact size that does not compromise efficiency
Perfect solution for retrofits
Permits forklift loading for easy installation
Johnson Controls, Inc. —34
Greater design flexibility:
9 package models or
modular combinations
Controls can be
parent/child controller if
application requires
Maximum of 32 units
below 130 kW
Maximum of 16 units
above 130 kW
PERFORMANCE WITHOUT COMPROMISEMODULAR CONFIGURATION TO MEET CHANGING BUILDING DEMANDS
Johnson Controls, Inc. —35
No programming or commissioning tools required Routes the energy requirements of the space to the heating/cooling requirement Ability to move from an average Class D efficiency classification to a Class A, according to EN15232
ADVANCED CONTROL MADE EASYVERASYSTM A PLUG-AND-PLAY EXPERIENCE
Johnson Controls, Inc. —36
Standard equipment:Optiview LTTM 7" TouchscreenLow Ambient Kit (down to -17.8ºC ambient)Smart Equipment Board (Verasys compatible)Languages (EN, FR, DE, IT, ES, PL, RU, DU, SW)Electronic Expansion ValvesDual Relief ValvesFlow Switch, Water Filter & VictaulicIPx4 steel enclosure
Options & Accessories:Ultra Quiet KitWire Grills Condenser side with Panels lower sectionPump Kits VSD, Low & High Pressure, Single or Dual Pump
External Mounting for 45-130 (1&2 fan units)Internal Mounting for 160-260 (3&4 fan units)
Pump Kits Fix Speed Internal Mounting (work in progress)AVM: 1” & 2” Springs, Neoprene IsolatorsModular kits (remote indoor controller+ water temp sensor)
YMAA/YMPA MAIN COMPONENTS
Johnson Controls, Inc. —37
Standard equipment:Optiview LTTM 7" TouchscreenLow Ambient Kit (down to -17.8ºC ambient)Smart Equipment Board (Verasys compatible)Languages (EN, FR, DE, IT, ES, PL, RU, DU, SW)Electronic Expansion ValvesDual Relief ValvesFlow Switch, Water Filter & VictaulicIPx4 steel enclosure
Options & Accessories:Ultra Quiet KitWire Grills Condenser side with Panels lower sectionPump Kits VSD, Low & High Pressure, Single or Dual Pump
External Mounting for 45-130 (1&2 fan units)Internal Mounting for 160-260 (3&4 fan units)
Pump Kits Fix Speed Internal Mounting (work in progress)AVM: 1” & 2” Springs, Neoprene IsolatorsModular kits (remote indoor controller+ water temp sensor)
YMAA/YMPA MAIN COMPONENTS
SC-Equip
Verasys
Johnson Controls, Inc. —38
Standard equipment:Optiview LTTM 7" TouchscreenLow Ambient Kit (down to -17.8ºC ambient)Smart Equipment Board (Verasys compatible)Languages (EN, FR, DE, IT, ES, PL, RU, DU, SW)Electronic Expansion ValvesDual Relief ValvesFlow Switch, Water Filter & VictaulicIPx4 steel enclosure
Options & Accessories:Ultra Quiet KitWire Grills Condenser side with Panels lower sectionPump Kits VSD, Low & High Pressure, Single or Dual Pump
External Mounting for 45-130 (1&2 fan units)Internal Mounting for 160-260 (3&4 fan units)
Pump Kits Fix Speed Internal Mounting (work in progress)AVM: 1” & 2” Springs, Neoprene IsolatorsModular kits (remote indoor controller+ water temp sensor)
YMAA/YMPA MAIN COMPONENTS
Victaulic Paddle Type Flow Switch
20 mesh Y-shaped Strainer
Electric Heater
Johnson Controls, Inc. —39
Standard equipment:Optiview LTTM 7" TouchscreenLow Ambient Kit (down to -17.8ºC ambient)Smart Equipment Board (Verasys compatible)Languages (EN, FR, DE, IT, ES, PL, RU, DU, SW)Electronic Expansion ValvesDual Relief ValvesFlow Switch, Water Filter & VictaulicIPx4 steel enclosure
Options & Accessories:Ultra Quiet KitWire Grills Condenser side with Panels lower sectionPump Kits VSD, Low & High Pressure, Single or Dual Pump
External Mounting for 45-130 (1&2 fan units)Internal Mounting for 160-260 (3&4 fan units)
Pump Kits Fix Speed Internal Mounting (work in progress)AVM: 1” & 2” Springs, Neoprene IsolatorsModular kits (remote indoor controller+ water temp sensor)
YMAA/YMPA MAIN COMPONENTS
Pump Kit 1&2 fan unit
VSD pump/EC motor
Johnson Controls, Inc. —40
Thank You!
Slide Number 1Slide Number 2Slide Number 3Slide Number 4Slide Number 5Slide Number 6Slide Number 7Slide Number 8Slide Number 9Slide Number 10Slide Number 11Slide Number 12Slide Number 13Slide Number 14Slide Number 15Slide Number 16Slide Number 17Slide Number 18Slide Number 19Slide Number 20Slide Number 21Slide Number 22Slide Number 23Slide Number 24Slide Number 25York® AmichiTM (YMAA/YMPA) Series�Air-cooled DC Inverter Scroll Chillers And Heat Pumps�State Of The Art��Most Efficient��Compact��Modular/Scalable��Smart Connected�Slide Number 28Slide Number 29Slide Number 30Slide Number 31Slide Number 32Slide Number 33Slide Number 34Slide Number 35Slide Number 36Slide Number 37Slide Number 38Slide Number 39Slide Number 40