  • 8/2/2019 TN_RF_007 - BeanDevice DataLogger User Guide

    1/24

    Ref : RF_TN_007 V1.0

    Beanair 1, mail Gay Lussac - 95000 Neuville-sur-Oise France

    www.beanair.com

    T ECHNICAL NOTE BeanDevice DataLogger User Guide

  • 8/2/2019 TN_RF_007 - BeanDevice DataLogger User Guide

    2/24

    Plug and Play Wireless Sensor Networks Ref: TN_RF_007 Version: 1.0

    BeanDevice DataLogger user guide Document Type : Technical Note

    Rf : DataLogger Capacity Date de publication : 10/06/2011 Modle : SES_V120 Page : 1 / 24

    DOCUMENT

    Document number Version V1.0External Reference RF_NT_005 V1.0 Publication date 12/03/2011Author Christophe DONTEGREUILInternal Reference Project Code N.A.Document Name BeanDevice DataLogger User Guide

    VALIDATION

    Function Recipients ForValidationForinformation

    Reader XAuthor X

    MAILING LIST Function Recipients For action For Info

    Staffer 1 Jules SACHOT XStaffer 2 Christophe DONTEGREUIL X

    Updates Version Date Author Evolution & Status

    V1.0 12/03/2011 Christophe

    DONTEGREUILFirst version of the document

  • 8/2/2019 TN_RF_007 - BeanDevice DataLogger User Guide

    3/24

    Plug and Play Wireless Sensor Networks Ref: TN_RF_007 Version: 1.0

    BeanDevice DataLogger user guide Document Type : Technical Note

    Rf : DataLogger Capacity Date de publication : 10/06/2011 Modle : SES_V120 Page : 2 / 24

    1. TECHNICAL SUPPORT .................................................................................................................................... 4

    2. VISUAL SYMBOLS DEFINITION ...................................................................................................................... 5

    3. AIM OF THE DOCUMENT ................................................................................................................................ 6

    4. ABOUT DATALOGGER FEATURE .................................................................................................................. 7

    5. DATALOGGER CAPACITY ............................................................................................................................... 8

    6. DATALOGGING PROCESS STEP-BY-STEP ................................................................................................... 9

    7. EMBEDDED FLASH MEMORY MANAGEMENT............................................................................................ 14 7.1 How a full memory is managed? ............................................................................................................. 14 7.2 Time processing ...................................................................................................................................... 14

    8. DATALOGGER CONFIGURATION WITH THE BEANSCAPE .................................................................... 15 8.1 Data Acquisition configuration tag ........................................................................................................... 15

    8.1.1 Configure a Data Acquisition mode with Log only option .............................................................. 16 8.1.1 Configure a Data Acquisition mode with Tx & Log option ............................................................. 17 8.1.1 Configure a Data Acquisition mode with Tx option ........................................................................ 18

    8.2 Logger tag ............................................................................................................................................... 19 8.2.1 How to access to Logger Tag ? .................................................................................................. 19 8.2.2 Logger tag composition ................................................................................................................. 19 8.2.3 Logger status ................................................................................................................................. 20

    8.2.4 Logger manager ............................................................................................................................ 20 8.2.5 Acquisition information .................................................................................................................. 22 8.2.6 Logger memory configuration ........................................................................................................ 23

    Contents

  • 8/2/2019 TN_RF_007 - BeanDevice DataLogger User Guide

    4/24

    Plug and Play Wireless Sensor Networks Ref: TN_RF_007 Version: 1.0

    BeanDevice DataLogger user guide Document Type : Technical Note

    Rf : DataLogger Capacity Date de publication : 10/06/2011 Modle : SES_V120 Page : 3 / 24

    Disclaimer

    The information contained in this document is the proprietary information of BeanAir.

    The contents are confidential and any disclosure to persons other than the officers, employees, agents orsubcontractors of the owner or licensee of this document, without the prior written consent of BeanAir Ltd, isstrictly prohibited.

    BeanAir makes every effort to ensure the quality of the information it makes available. Notwithstanding the

    foregoing, BeanAir does not make any warranty as to the information contained herein, and does not acceptany liability for any injury, loss or damage of any kind incurred by use of or reliance upon the information.

    BeanAir disclaims any and all responsibility for the application of the devices characterized in this document,and notes that the application of the device must comply with the safety standards of the applicable country,and where applicable, with the relevant wiring rules.

    BeanAir reserves the right to make modifications, additions and deletions to this document due totypographical errors, inaccurate information, or improvements to programs and/or equipment at any time andwithout notice.

    Such changes will, nevertheless be incorporated into new editions of this document.Copyright: Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its

    contents and communication thereof to others without express authorization are prohibited. Offenders will beheld liable for payment of damages. All rights are reserved.

    Copyright BeanAir Ltd. 2010.

  • 8/2/2019 TN_RF_007 - BeanDevice DataLogger User Guide

    5/24

    Plug and Play Wireless Sensor Networks Ref: TN_RF_007 Version: 1.0

    BeanDevice DataLogger user guide Document Type : Technical Note

    Rf : DataLogger Capacity Date de publication : 10/06/2011 Modle : SES_V120 Page : 4 / 24

    1. TECHNICAL SUPPORT

    For general contact, technical support, to report documentation errors and to order manuals, contactBeanAir Technical Support Center (BTSC) at:[email protected]

    For detailed information about where you can buy the BeanAir equipment/software or forrecommendations on accessories and components visit:

    www.beanair.com

    To register for product news and announcements or for product questions contact BeanAirs Tec hnicalSupport Center (BTSC).

    Our aim is to make this user manual as helpful as possible. Please keep us informed of your comments andsuggestions for improvements. BeanAir appreciates feedback from the users.

    mailto:[email protected]:[email protected]://www.beanair.com/http://www.beanair.com/http://www.beanair.com/mailto:[email protected]
  • 8/2/2019 TN_RF_007 - BeanDevice DataLogger User Guide

    6/24

    Plug and Play Wireless Sensor Networks Ref: TN_RF_007 Version: 1.0

    BeanDevice DataLogger user guide Document Type : Technical Note

    Rf : DataLogger Capacity Date de publication : 10/06/2011 Modle : SES_V120 Page : 5 / 24

    2. VISUAL SYMBOLS DEFINITION

    Visual Definition

    Caution or Warning Alerts the user with important information about BeanAir wireless sensor networks (WSN), if this information is not followed, the equipment /software may fail or malfunction.

    Danger This information MUST be followed if not you may damage the equipment permanently or bodily injury may occur.

    Tip or Information Provides advice and suggestions that may be useful when installing BeanAir Wireless Sensor Networks.

  • 8/2/2019 TN_RF_007 - BeanDevice DataLogger User Guide

    7/24

    Plug and Play Wireless Sensor Networks Ref: TN_RF_007 Version: 1.0

    BeanDevice DataLogger user guide Document Type : Technical Note

    Rf : DataLogger Capacity Date de publication : 10/06/2011 Modle : SES_V120 Page : 6 / 24

    3. AIM OF THE DOCUMENT

    This document is made to bring you all the information you could possibly need to be able to useour BeanDevice DataLogger in total independence.

  • 8/2/2019 TN_RF_007 - BeanDevice DataLogger User Guide

    8/24

    Plug and Play Wireless Sensor Networks Ref: TN_RF_007 Version: 1.0

    BeanDevice DataLogger user guide Document Type : Technical Note

    Rf : DataLogger Capacity Date de publication : 10/06/2011 Modle : SES_V120 Page : 7 / 24

    4. ABOUT DATALOGGER FEATURE

    All the BeanDevice integrates a dataLogger based on a flash memory. It integrates a wide spectrum of advanced features:

    A flash memory size adapted for each application field:o BeanDevice Ecosensor products can log up to 32700 data acquisition;o BeanDevice SmartSensor and ProcessSensor can log up to 1.000.000 data acquisition

    Very fast download (< 2-3 minutes);A great flexibility for the user who can choose three configurations: Datalogging only or Datalogging + Data transmission or Data transmissionThe BeanDevice can operate in standalone mode, without the necessity to be always connected toa Wireless Sensor Networks;Datalogging is compatible with a maximum sampling rate of 2 Ksamples/s

  • 8/2/2019 TN_RF_007 - BeanDevice DataLogger User Guide

    9/24

    Plug and Play Wireless Sensor Networks Ref: TN_RF_007 Version: 1.0

    BeanDevice DataLogger user guide Document Type : Technical Note

    Rf : DataLogger Capacity Date de publication : 10/06/2011 Modle : SES_V120 Page : 8 / 24

    5. DATALOGGER CAPACITY

    This table shows the DataLogger capacity regarding the version of the BeanDevice:

    D a t a L o g g e r M o d e A c t i v a t e d : N

    u m

    b e r o

    f a c q u i s i t i o n p e r c h a n n e

    l V S D a t a a c q u i s i t i o n M o d e

    ( S t o p - a

    t - E n d R e c o r d i n g )

    B e a n D e v i c e S U N

    B N

    B e a n D e v i c e

    S U N

    B e a n D e v i c e

    S U N T

    B e a n D e v i c e

    S U N - T

    I R

    B e a n D e v i c e

    S U N T H

    B e a n D e v i c e

    A N - 4

    2 0

    B e a n D e v i c e

    A N - M

    V

    B e a n D e v i c e

    A N - V

    B e a n D e v i c e

    T O R

    B e a n D e v i c e

    T I R

    B e a n D e v i c e

    T S I

    B e a n D e v i c e

    T H

    B e a n D e v i c e

    H I - I N C

    B e a n D e v i c e

    A X - 3

    D

    L o w D u t y C y c

    l e

    2 9 7 8

    3 2 7 6 8

    1 6 3 8 4

    1 0 9 2 2

    1 0 9 2 2

    8 1 9 2

    8 1 9 2

    2 6 2 1 4 4

    8 7 3 8 1

    2 6 2 1 4 4

    3 4 9 5 2 5

    3 4 9 5 2 5

    5 2 4 2 8 8

    3 4 9 5 2 5

    S u r v e y

    2 9 7 8

    3 2 7 6 8

    1 6 3 8 4

    1 0 9 2 2

    1 0 9 2 2

    8 1 9 2

    8 1 9 2

    2 6 2 1 4 4

    8 7 3 8 1

    2 6 2 1 4 4

    3 4 9 5 2 5

    3 4 9 5 2 5

    5 2 4 2 8 8

    3 4 9 5 2 5

    A l a r m e

    2 9 7 8

    3 2 7 6 8

    1 6 3 8 4

    1 0 9 2 2

    1 0 9 2 2

    8 1 9 2

    8 1 9 2

    2 6 2 1 4 4

    8 7 3 8 1

    2 6 2 1 4 4

    3 4 9 5 2 5

    3 4 9 5 2 5

    5 2 4 2 8 8

    3 4 9 5 2 5

    S t r e a m

    i n g

    N / A

    N / A

    N / A

    N / A

    N / A

    8 1 9 2

    8 1 9 2

    2 6 2 1 4 4

    8 7 3 8 1 N

    / A

    N / A

    N / A

    5 2 4 2 8 8

    3 4 9 5 2 5

    S t r e a m

    i n g M a t

    h

    N / A

    N / A

    N / A

    N / A

    N / A

    8 1 9 2

    8 1 9 2

    2 6 2 1 4 4 N

    / A

    N / A

    N / A

    N / A

    5 2 4 2 8 8

    3 4 9 5 2 5

    D a t a L o g g e r M o d e A c t i v a t e d : N

    u m

    b e r o

    f a c q u i s i t i o n p e r c h a n n e

    l V S D a t a a c q u i s i t i o n M o d e

    ( R o

    l l - O

    v e r R e c o r d i n g )

    B e a n D e v i c e S U N

    B N

    B e a n D e v i c e

    S U N

    B e a n D e v i c e

    S U N T

    B e a n D e v i c e

    S U N - T

    I R

    B e a n D e v i c e

    S U N T H

    B e a n D e v i c e

    A N - 4

    2 0

    B e a n D e v i c e

    A N - M

    V

    B e a n D e v i c e

    A N - V

    B e a n D e v i c e

    T O R

    B e a n D e v i c e

    T I R

    B e a n D e v i c e

    T S I

    B e a n D e v i c e

    T H

    B e a n D e v i c e

    H I - I N C

    B e a n D e v i c e

    A X - 3

    D

    L o w D u t y C y c

    l e

    N o n d i s p o n i b

    l e

    3 2 7 6 8

    1 6 3 8 4

    1 0 9 2 2

    1 0 9 2 2

    8 1 9 2

    8 1 9 2

    2 6 2 1 4 4

    8 7 3 8 1

    2 6 2 1 4 4

    3 4 9 5 2 5

    3 4 9 5 2 5

    5 2 4 2 8 8

    3 4 9 5 2 5

    S u r v e y

    N o n d i s p o n i b

    l e

    3 2 7 6 8

    1 6 3 8 4

    1 0 9 2 2

    1 0 9 2 2

    8 1 9 2

    8 1 9 2

    2 6 2 1 4 4

    8 7 3 8 1

    2 6 2 1 4 4

    3 4 9 5 2 5

    3 4 9 5 2 5

    5 2 4 2 8 8

    3 4 9 5 2 5

    A l a r m e

    N o n d i s p o n i b

    l e

    3 2 7 6 8

    1 6 3 8 4

    1 0 9 2 2

    1 0 9 2 2

    8 1 9 2

    8 1 9 2

    2 6 2 1 4 4

    8 7 3 8 1

    2 6 2 1 4 4

    3 4 9 5 2 5

    3 4 9 5 2 5

    5 2 4 2 8 8

    3 4 9 5 2 5

    S t r e a m

    i n g

    N o n d i s p o n i b

    l e

    N / A

    N / A

    N / A

    N / A

    8 1 9 2

    8 1 9 2

    2 6 2 1 4 4

    8 7 3 8 1 N

    / A

    N / A

    N / A

    5 2 4 2 8 8

    3 4 9 5 2 5

    S t r e a m

    i n g M a t

    h

    N o n d i s p o n i b

    l e

    N / A

    N / A

    N / A

    N / A

    8 1 9 2

    8 1 9 2

    2 6 2 1 4 4 N

    / A

    N / A

    N / A

    N / A

    5 2 4 2 8 8

    3 4 9 5 2 5

  • 8/2/2019 TN_RF_007 - BeanDevice DataLogger User Guide

    10/24

    Plug and Play Wireless Sensor Networks Ref: TN_RF_007 Version: 1.0

    BeanDevice DataLogger user guide Document Type : Technical Note

    Rf : DataLogger Capacity Date de publication : 10/06/2011 Modle : SES_V120 Page : 9 / 24

    6. DATALOGGING PROCESS STEP-BY-STEP

    Step 1 Install your BeanDevice on your equipment Configure fully your Beandevice before starting Data Logging

    Step 2

    Configure your Data Acquisition mode of your BeanDevice, choose properly yourDatalogger option: Datalogging only or Datalogging + Data transmission

    The BeanGateway sends an OTAC for starting the new data acquisition mode on theBeanDevice

    All the logs are recorded on an embedded memory flash of the Beandevice

    Data Loggingon flashmemory

    Data Logging

    on flashmemory

    Data Loggingon flashmemory

  • 8/2/2019 TN_RF_007 - BeanDevice DataLogger User Guide

    11/24

    Plug and Play Wireless Sensor Networks Ref: TN_RF_007 Version: 1.0

    BeanDevice DataLogger user guide Document Type : Technical Note

    Rf : DataLogger Capacity Date de publication : 10/06/2011 Modle : SES_V120 Page : 10 / 24

    DataLogging + Data transmission

    Step 3 If you choose DataLogging with data transmission , the BeanDevice transmits &

    records all the data simultanously; If you choose DataLogging without RF transmission, the BeanDevice records all the

    data without any transmission

    BeanGateway

    BeanDevice AN-XX BeanDevice SUN-T

    BeanDevice AX-3D

    BeanDevice TOR

  • 8/2/2019 TN_RF_007 - BeanDevice DataLogger User Guide

    12/24

    Plug and Play Wireless Sensor Networks Ref: TN_RF_007 Version: 1.0

    BeanDevice DataLogger user guide Document Type : Technical Note

    Rf : DataLogger Capacity Date de publication : 10/06/2011 Modle : SES_V120 Page : 11 / 24

    DataLogging without Data transmission

    A standalone installation of the BeanDevice can be done without the necessity to be connected to theBeanGateway.If the Power management mode of your BeanDevice is configured in sleeping with Network listeningmode, every N cycle (defined by the user) the Beandevice listens for a download request coming from theBeangateway.

    If your Beangateway was used to configure the DataLogger feature of your Beandevice:Dont try to change the PAN ID or the RF channel . Your BeanDevice will not be able to reach theBeanGateway during the Network Listening process. If this is the case, you must power off then power on your Beandevice, a new WSN association will be done.

    Datalogging

    Every N Cycle theBeanDevice listens for aDownload request coming

    from the BeanGateway

  • 8/2/2019 TN_RF_007 - BeanDevice DataLogger User Guide

    13/24

    Plug and Play Wireless Sensor Networks Ref: TN_RF_007 Version: 1.0

    BeanDevice DataLogger user guide Document Type : Technical Note

    Rf : DataLogger Capacity Date de publication : 10/06/2011 Modle : SES_V120 Page : 12 / 24

    Step 4 At everytime, you can send a request (through the BeanScape) for downloading al the Dataacquisition logged on the BeanDevice

    This request is bakcuped on the BeanGateway and will be transmitted to the BeanDevicewhen it starts to listen to the BeanGateway

    The BeanScape sends a request for downloading all the Data acquisition logged on the BeanDevice

    Request pending

    Step 5

    The BeanGateway must be placed near the BeanDevice; If the Power management mode of your BeanDevice is configured in sleeping mode with

    Network listening , the request will be received by the BeanDevice when it started listening tothe BeanGateway;

    If the Power management mode of your BeanDevice is configured in sleeping mode , therequest will be received when you power off and then power up your BeanDevice

    1

    2

  • 8/2/2019 TN_RF_007 - BeanDevice DataLogger User Guide

    14/24

    Plug and Play Wireless Sensor Networks Ref: TN_RF_007 Version: 1.0

    BeanDevice DataLogger user guide Document Type : Technical Note

    Rf : DataLogger Capacity Date de publication : 10/06/2011 Modle : SES_V120 Page : 13 / 24

    Step 6 The BeanDevice starts sending its data logs The BeanScape displays the download process; At the end of the download process: a log file is created/updated in the BeanScape log folder

    1

    2

    Data logs are backuped in the BeanScape

    log file

    3

    The BeanScapedispplays thedownload process

  • 8/2/2019 TN_RF_007 - BeanDevice DataLogger User Guide

    15/24

    Plug and Play Wireless Sensor Networks Ref: TN_RF_007 Version: 1.0

    BeanDevice DataLogger user guide Document Type : Technical Note

    Rf : DataLogger Capacity Date de publication : 10/06/2011 Modle : SES_V120 Page : 14 / 24

    7. EMBEDDED FLASH MEMORY MANAGEMENT

    7.1 HOW A FULL MEMORY IS MANAGED?

    The user can choose how the embedded flash memory must be managed if it is full:

    Data Logging can stop;

    Data Logging continues by erasing the oldest recorded data

    7.2 TIME PROCESSING

    Full Download time Typ

    BeanDevice SUN-XX

  • 8/2/2019 TN_RF_007 - BeanDevice DataLogger User Guide

    16/24

    Plug and Play Wireless Sensor Networks Ref: TN_RF_007 Version: 1.0

    BeanDevice DataLogger user guide Document Type : Technical Note

    Rf : DataLogger Capacity Date de publication : 10/06/2011 Modle : SES_V120 Page : 15 / 24

    8. DATALOGGER CONFIGURATION WITH THE BEANSCAPE

    8.1 DATA ACQUISITION CONFIGURATION TAG

    Tx only : The BeanDevice transmits the data acquisition without Datalogging

    Log only : The Beandevice logs the data acquisition without wireless transmission

    Tx & Log: The BeanDevice transmits and logs the data acquisition;

    Data acquisition mode configuration

    DataLogger options

  • 8/2/2019 TN_RF_007 - BeanDevice DataLogger User Guide

    17/24

    Plug and Play Wireless Sensor Networks Ref: TN_RF_007 Version: 1.0

    BeanDevice DataLogger user guide Document Type : Technical Note

    Rf : DataLogger Capacity Date de publication : 10/06/2011 Modle : SES_V120 Page : 16 / 24

    8.1.1 Configure a Data Acquisition mode with Log only option

    If the user chooses to configure the Data Acquisition mode with Log option activated:

    1/ Configure yourData acquisitionmode

    2/ ChooseLog only

    3/ Clickon

    validate

    5/ Log led isactivated

    4/ A pop-upwindow

    confirms yournew

    configuration

  • 8/2/2019 TN_RF_007 - BeanDevice DataLogger User Guide

    18/24

    Plug and Play Wireless Sensor Networks Ref: TN_RF_007 Version: 1.0

    BeanDevice DataLogger user guide Document Type : Technical Note

    Rf : DataLogger Capacity Date de publication : 10/06/2011 Modle : SES_V120 Page : 17 / 24

    8.1.1 Configure a Data Acquisition mode with Tx & Log option

    If the user chooses to configure the Data Acquisition mode with Tx & Log option activated:

    5/ Log & Txleds are

    activated

    4/ A pop-upwindow confirms

    your newconfiguration

    1/ Configure yourData acquisitionmode

    3/ Clickon

    validate

    2/ Choose Tx& Log option

  • 8/2/2019 TN_RF_007 - BeanDevice DataLogger User Guide

    19/24

    Plug and Play Wireless Sensor Networks Ref: TN_RF_007 Version: 1.0

    BeanDevice DataLogger user guide Document Type : Technical Note

    Rf : DataLogger Capacity Date de publication : 10/06/2011 Modle : SES_V120 Page : 18 / 24

    8.1.1 Configure a Data Acquisition mode with Tx option

    If the user chooses to configure the Data Acquisition with Tx option activated:

    7/ Tx led isactivated

    1/ Configure yourData acquisitionmode

    2/ Choose Txoption

    4/ If the DatLoggeroption was

    activated , it willbe stopped if you

    click on yes

    6/ A pop-up

    windowconfirms your

    newconfiguration

    3/ Click onvalidate

  • 8/2/2019 TN_RF_007 - BeanDevice DataLogger User Guide

    20/24

    Plug and Play Wireless Sensor Networks Ref: TN_RF_007 Version: 1.0

    BeanDevice DataLogger user guide Document Type : Technical Note

    Rf : DataLogger Capacity Date de publication : 10/06/2011 Modle : SES_V120 Page : 19 / 24

    8.2 LOGGER TAG

    8.2.1 How to access to Logger Tag ?

    1. Open your BeanScape

    2. Click on your BeanDevice profile

    3. Click on Logger tag

    8.2.2 Logger tag composition

    The Logger tag is composed of five different fields:Logger Status

    Logger manager

    Acquisition information

    Logger memory configuration

    Logger status

    Click on yourBeanDevice

    profileClick on

    Logger Tag

  • 8/2/2019 TN_RF_007 - BeanDevice DataLogger User Guide

    21/24

    Plug and Play Wireless Sensor Networks Ref: TN_RF_007 Version: 1.0

    BeanDevice DataLogger user guide Document Type : Technical Note

    Rf : DataLogger Capacity Date de publication : 10/06/2011 Modle : SES_V120 Page : 20 / 24

    8.2.3 Logger status

    Logger status : Displays loggers status, four status are available:

    o Ready : the Datalogger is ready to register data

    o NotInit : the Datalogger is not initialized;

    o Active logs only : Data acquisition is logged only;

    o Active Tx and Log : Data acquisition is logged & transmitted by Radio;o Stopped : Datalogger is stopped;

    Download process : Displays the download process 0 to 100%. If 100%, all the data logs aresuccessfully downloaded on your PC.

    Donwload status : Displays the download status , two types of status are available:

    o Processing : Data logs download is under process;

    o Completed: Data Logs are completely downloaded on your PC;

    8.2.4 Logger manager

    Stop : Stops Data Logging process

    Erase : Stops & Erases all the logs on flash memory

    Download : Starts to download all the logs on the flash memory

    Cancel : Stops the download process

  • 8/2/2019 TN_RF_007 - BeanDevice DataLogger User Guide

    22/24

    Plug and Play Wireless Sensor Networks Ref: TN_RF_007 Version: 1.0

    BeanDevice DataLogger user guide Document Type : Technical Note

    Rf : DataLogger Capacity Date de publication : 10/06/2011 Modle : SES_V120 Page : 21 / 24

    When you click on Erase :

    When you click on Download:

    A pop-upwindowopens

    Loggerstatus

    changesto NotInit

    A pop-upwindowopens

    Data logs aredownloaded

    by theBeanScape

  • 8/2/2019 TN_RF_007 - BeanDevice DataLogger User Guide

    23/24

  • 8/2/2019 TN_RF_007 - BeanDevice DataLogger User Guide

    24/24

    Plug and Play Wireless Sensor Networks Ref: TN_RF_007 Version: 1.0

    BeanDevice DataLogger user guide Document Type : Technical Note

    8.2.6 Logger memory configuration

    When the flash memory is full:

    Logs will restart at the beginning (Check Rollover recording option)

    Data Logging is stopped (Check Stop at end recording option)

    Click on Validate to validate your choice.