Customized Titanium Membrane
152
Custom
ized Titanium
Mem
brane
Introduction
has developed independently by Neobiotech Co., Ltd., Which is the customized
titanium membrane with minimum cutting and bending of it for attaching on the location of part used. This
product, customized titanium membrane, solved the existed rectangle membrane's own inconvenience of
cutting problem.
Customized Titanium MembraneC
ustomized
Titanium M
emb
rane
153
Introduction
1. Biocompatibility
Cp. Ti material has an excellent biological stability, and it is beneficial to bone formation.
2. Strong
Compare to absorbable membrane, it has a superior strength and excellent retention of BMP space.
3. Flexibility
Has an excellent flexibility due to the thinness, and it can easily produce a desired shape.
4. Customized shape
Depending on the location, it provides variety sizes of membrane that are suitable for treatment use.
Membrane with a minimum of trimming can be made into the shape you want.
5. Implant fixation
Even without the use of membrane fixing screw, it can be fixed directly to Implant.
6. Vertical Augmentation
Vertical Augmentation is adjustable with using 1mm, 1.5mm, 2mm of CTi Spacer.
7. 1-stage Surgery
After completing GBR, the CTi-Mem can be easily removed without having 2-stage surgery.
Advantage of CTi-Mem
Customized Titanium Membrane
154
Custom
ized Titanium
Mem
brane
Introduction
CTi-mem Characteristic
1
2
3
4
5
C
6
Lingual fingerMain function is to maintain the efficient space by covering the 2~3mm of lingual defect with easy bending. Simple
cutting if necessary.
Proximal fingerNecessary when vertical augmentation of Misial&distal defect, shape formation available with easy bending. Cut
the unnecessary part After measure the width of proximal.
Lateral augmentation part- Put the C part as the centre and bending of a curved for 2~3mm thick side bone formation.
- Bending the side extrusion inwards in order to protect bone transplant and form the space. Porous exists to
minimize the soft tissue exposure.
Lateral cover- Cover part of side transplant bone materials. Choose the size depends on defect length.
- Three dimensional bending available, no porous exists to be able to remove the CTi-mem with simple 2nd surgery.
FootProtect the transplant material as bending inwards, have membrane fixation by contacting the existing bone.
Fixing holeThe hole formed to fix the CTi-mem to fixture. Firstly connect the CTi Spacer to fixture, lift up the CTi-mem and
then fix with the CTi Healing Abutment or CTi Cover Cap. Vertical bone formation can be decided depends on CTi
Spacer height.
1
2
3
4
5
6
CTI-mem 1
• A-Type 1wall Augmentation(Buccal or Lingual)
• B-Type 2wall Augmentation(Buccal - Proximal)
P(mm)Proximal Width
W(mm)Buccal Width
L(mm)Buccal Length Code Code
4 8 6 A1 ATMBN0810S
4 10 8 A2 ATMBN0912S
4 10 10 A3 ATMBN0915S
P(mm)Proximal Width
W(mm)Buccal Width
L(mm)Buccal Length Type Code
7 9
6 B1 ATMBN0910L
8 B2 ATMBN0912L
10 B3 ATMBN0915L
10 12
6 B4 PTMBN1210S
8 B5 PTMBN1212S
10 B6 PTMBN1215S
12 12
6 B7 PTMBN1210L
8 B8 PTMBN1212L
10 B9 PTMBN1215L
• C-Type 3wall Augmentation(Buccal - Lingual - Proximal)
P(mm)Proximal Width
W(mm)Buccal Width
L(mm)Buccal Length Type Code
7 9
6 C1 ATMLN0910L
8 C2 ATMLN0912L
10 C3 ATMLN0915L
10 12
6 C4 PTMLN1210S
8 C5 PTMLN1212S
10 C6 PTMLN1215S
12 12
6 C7 PTMLN1210L
8 C8 PTMLN1212L
10 C9 PTMLN1215L
CTi-mem
CTI mem 02
• D-Type ITI Type(Non-Fixed) 1wall Augmentation
P(mm)Proximal Width
W(mm)Buccal Width
L(mm)Buccal Length Code Code
7 9
6 D1 ATUBN0910L
8 D2 ATUBN0912L
10 D3 ATUBN0915L
• E-Type Universal Type(Submerged & Non-Fixed)
P(mm)Proximal Width
L(mm)Buccal Length Type Code
12 15 E1 CTM1215
12 20 E2 CTM1220
15 20 E3 CTM1520
• EB CTi SpacerType Diameter Hight(mm) Code
Narrow Ø3.5
1 ENCTS3710
1.5 ENCTS3715
2 ENCTS3720
Regular Ø4.0
1 ERCTS4010
1.5 ERCTS4015
2 ERCTS4020
Wide(3i) Ø5.0
1 EICTS5010
1.5 EICTS5015
2 EICTS5020
Wide(Branemark) Ø5.0
1 EBCTS5010
1.5 EBCTS5015
2 EBCTS5020
• D-Type ITI Type(Non-Fixed) 2wall Augmentation
P(mm)Proximal Width
W(mm)Buccal Width
L(mm)Buccal Length Type Code
10 12
6 D4 PTUBN1210S
8 D5 PTUBN1212S
10 D6 PTUBN1215S
Hight
Diameter
CTi-mem
CTI mem 03
CTi-mem
• Astra SpacerFixture Size Diameter Hight(mm) Code
Ø3.0(Yellow) Ø3.5
0.5 ASCTS1405
1.0 ASCTS1410
1.5 ASCTS1415
2.0 ASCTS1420
Ø3.5 / Ø4.0(Aqua) Ø4.0
0.5 ASCTS1605
1.0 ASCTS1610
1.5 ASCTS1615
2.0 ASCTS1620
Ø4.5 / Ø5.0(Lilac) Ø4.0
0.5 ASCTS2005
1.0 ASCTS2010
1.5 ASCTS2015
2.0 ASCTS2020
• Zimmer SpacerFixture Size Diameter Hight(mm) Code
Taper Screw-Vent.Screw-Vent
Plateform Ø3.5 FixtureØ3.5
0.5 ZSVCTS3505
1.0 ZSVCTS3510
1.5 ZSVCTS3515
2.0 ZSVCTS3520
Taper Screw-Vent.Screw-VentPlateform
Ø3.5 / Ø4.5 Fixture
Ø4.5
0.5 ZSVCTS4505
1.0 ZSVCTS4510
1.5 ZSVCTS4515
2.0 ZSVCTS4520
Taper Screw-VentPlateform
Ø5.7 FixtureØ5.7
0.5 ZSVCTS5705
1.0 ZSVCTS5710
1.5 ZSVCTS5715
2.0 ZSVCTS5720
• IS CTi Spacer
Diameter Hight(mm) Code
Ø4.0
0.5 ISCTS4005
1 ISCTS4010
1.5 ISCTS4015
2 ISCTS4020
Hight
Diameter
Hight
Diameter
Hight
Diameter
CTI mem 04
CTi-mem
• CTi Cover Cap
Diameter Hight(mm) Code
Ø4.0 1.5 CTC40
• Dentsply SpacerFixture Size Diameter Hight(mm) Code
Ø3.0 Fixture Ø3.0
0.5 XIVECTS3005
1.0 XIVECTS3010
1.5 XIVECTS3015
2.0 XIVECTS3020
Ø3.4 Fixture Ø3.4
0.5 XIVECTS3405
1.0 XIVECTS3410
1.5 XIVECTS3415
2.0 XIVECTS3420
Ø3.8 / Ø4.5 / Ø5.5 Fixture Ø4.5
0.5 XIVECTS4505
1.0 XIVECTS4510
1.5 XIVECTS4515
2.0 XIVECTS4520
• CTi Healing Abutment
Diameter 1(Ø) Diameter 2(Ø) Hight(mm) Code
Ø4.0
Ø4.03.0 CHAG404030
4.0 CHAG404040
Ø5.03.0 CHAG405030
4.0 CHAG405040
* Only for Xive
Hight
Hight
Diameter
Diameter 1
Diameterv2
Hight
Diameter
CTI mem 05
CTi-mem
• CTi-mem Contouring plier
• CTi Cover Cap Driver
• CTi Guage
Code MCCD
Code MG00
Code MCCP
Customized Titanium MembraneC
ustomized
Titanium M
emb
rane
159
User Guide
1. Finish the implantation of the Fixture.
2. Choose CTi-Mem by using the measurement from CTi gauge and length space of bone graft.
3. Combine the membrane healing post with the fixture. By selecting the post, you need to know the
system of the implant, volume of the bone graft and EB and IS implant have two types of height(1mm,
1.5mm, 2mm) which this information can give good selection.
4. Proceed Bone graft.
5. Make model of the selected CTI- Mem. Do not bend rapidly in the same area or it will fracture the
CTI- Mem.
6. Stable the CTI-Mem and combine the membrane healing cap or membrane cover cap with below 10 Ncm. - With the gum height use suitable healing cap.
- Use cover cap for 2nd stage surgery.
7. Suture the Soft tissue.
1. A type : 1 wall augmentation
Placement for buccal in bone defect area
Implant at the area of bonedefect
Combine CTi Spacer withimplant
Image of CTi Spacer withimplant
Bone graft at Bone defect area
Bend Cti-mem with Con-touring plier
Bend Suitable Form byBending CTi-mem
Place the mount at CTi Spacer Before suture, combine CTiHealing abutment or CTiCover cap with CTi-mem
Customized Titanium Membrane
160
Custom
ized Titanium
Mem
brane
User Guide
2. B type : 2 wall augmentation
Placement for buccal, proximal in bone defect area
3. C type : 3 wall augmentaion
Placement for buccal, proximal and lingual in bone defect area
Implant at the area of bonedefect
Combine CTi Spacer withimplant
Image of CTi Spacer withimplant
Bone graft at Bone defect area
Bend Cti-mem with Con-touring plier
Bend Suitable Form byBending CTi-mem
Place the mount at CTi Spacer Before suture, combine CTiHealing abutment or CTiCover cap with CTi-mem
Implant at the area of bonedefect
Combine CTi Spacer withimplant
Image of CTi Spacer withimplant
Bone graft at Bone defect area
Bend Cti-mem with Con-touring plier
Bend Suitable Form byBending CTi-mem
Place the mount at CTi Spacer Before suture, combine CTiHealing abutment or CTiCover cap with CTi-mem
Customized Titanium MembraneC
ustomized
Titanium M
emb
rane
161
User Guide
4. D type : 1 wall agumentation for ITI type
Placement for buccal in bone defect area
5. D type : 2 wall agumentation for ITI type
Placement for buccal and proximal in bone defect area
Detect the area of bone defect Combine cover screw orhealing abutment
Bone graft at Bone defect area Bend Cti-mem with Contouringplier
Bend Suitable Form by BendingCTi-mem
Before suture, place CTi -memat bone defect area
Detect the area of bone defect Combine cover screw orhealing abutment
Bone graft at Bone defectarea
Bend Cti-mem with Contouringplier
Bend Suitable Form by BendingCTi-mem
Before suture, place CTi -memat bone defect area
Customized Titanium Membrane
162
Custom
ized Titanium
Mem
brane
User Guide
6. E type : Non-fixed Submerged
Placement for large bone defect area
1. Practitioners should use after fully understand the handling and precautions of the product.
2. Since the product is supplied as sterile, CTi-mem should be used immediately after it is opened from
the package.
3. In the case of package is damaged, the condition of sterilization is likely to be damaged. Therefore, it
needs to be discarded.
4. Inadvertent exposure by a carelessness of suture can cause a redness, swelling and tissue to be
eliminated. Therefore, it needs to be removed.
5. Improper selection of patients or procedures can lead to a failure of treatment.
6. CTi-mem is a disposable single- use product. Do not reuse.
�Warning
Detect the area of bone defect Combine cover screw orhealing abutment
Bone graft at Bone defect area Bend Cti-mem with Contouringplier
Bend Suitable Form by BendingCTi-mem
Before suture, place CTi -memat bone defect area
Customized Titanium MembraneC
ustomized
Titanium M
emb
rane
163
CTi-mem Selection
1. Depends on the wall situation, choose A, B, C type from the CTi-men.
2. Proximal width (p) of Occlusal part that needs to be covered by Membrane is measured in oral with
determination of the 'p' size. If Proximal defect is not existed, amputate the proximal when it's 1wall
choose A, and when it's b-l defect choose C for the amputation.
3. W (Buccal Width) can be decided by P (Proximal Width) and P can be measured From B and C.
New CTi-memNew CTi-mem provides �xing holes to give smoother access for �xing screws!
Bending Portion
Lateral Cover
Fixing Hole
Proximal Finger
ProximalFinger
Additional Finger
Fixing Hole
Lateral ThicknessForming Part
SpacerAfter connecting to the �xture, mount CTi-memon spacer and have statined using Cover Screw
Tent Screw
Fixing Screw
Mount CTi-mem on a statined Tent Screw and fasten using Cover Screw
After bending or customizing, the CTi-mem,tighten the �xing screw into the foot �xing hoel
• New CTi-mem Spec
[NA3] ATMBN0915SF [NB9] PTMBN1215LF [NC9] PTMLN1215LF [NE1] CTM1215F
[NE2] CTM1220F [NE3] CTM1520F [NE4] CTM2023F [NE5] CTM25F
12mm
10mm
12mm
20mm
12mm
20mm
15mm
20mm
23mm
20mm
30mm
12mm
10mm
12mm
15mm
12mm
4mm
11mm
10mm
CTI mem 06
New CTi-mem applicationguide
Fix the Tent Screw at a defect area Choose the New CTi-mem(NE5) Tighten the Fixing Screw into each side-foot Fixing hole
Make hole Tent Screw
Tighten the Fixing Screw into the rest of Fixing holes
Bone graft Tighten the New CTi-mem with Tent Screw by using Cover Screw
Complete the New CTi-mem with bone grafting by using Tent Screw and Fixing screw