+ All Categories
Home > Health & Medicine > CTi mem new version 01

CTi mem new version 01

Date post: 09-Aug-2015
Category:
Upload: kei-lim
View: 892 times
Download: 2 times
Share this document with a friend
16
Introduction CTi-mem Components User Guide CTi-mem Selection 152 155 159 163 Contents
Transcript

Introduction

CTi-mem Components

User Guide

CTi-mem Selection

152

155

159

163

Contents

Customized Titanium Membrane

152

Custom

ized Titanium

Mem

brane

Introduction

has developed independently by Neobiotech Co., Ltd., Which is the customized

titanium membrane with minimum cutting and bending of it for attaching on the location of part used. This

product, customized titanium membrane, solved the existed rectangle membrane's own inconvenience of

cutting problem.

Customized Titanium MembraneC

ustomized

Titanium M

emb

rane

153

Introduction

1. Biocompatibility

Cp. Ti material has an excellent biological stability, and it is beneficial to bone formation.

2. Strong

Compare to absorbable membrane, it has a superior strength and excellent retention of BMP space.

3. Flexibility

Has an excellent flexibility due to the thinness, and it can easily produce a desired shape.

4. Customized shape

Depending on the location, it provides variety sizes of membrane that are suitable for treatment use.

Membrane with a minimum of trimming can be made into the shape you want.

5. Implant fixation

Even without the use of membrane fixing screw, it can be fixed directly to Implant.

6. Vertical Augmentation

Vertical Augmentation is adjustable with using 1mm, 1.5mm, 2mm of CTi Spacer.

7. 1-stage Surgery

After completing GBR, the CTi-Mem can be easily removed without having 2-stage surgery.

Advantage of CTi-Mem

Customized Titanium Membrane

154

Custom

ized Titanium

Mem

brane

Introduction

CTi-mem Characteristic

1

2

3

4

5

C

6

Lingual fingerMain function is to maintain the efficient space by covering the 2~3mm of lingual defect with easy bending. Simple

cutting if necessary.

Proximal fingerNecessary when vertical augmentation of Misial&distal defect, shape formation available with easy bending. Cut

the unnecessary part After measure the width of proximal.

Lateral augmentation part- Put the C part as the centre and bending of a curved for 2~3mm thick side bone formation.

- Bending the side extrusion inwards in order to protect bone transplant and form the space. Porous exists to

minimize the soft tissue exposure.

Lateral cover- Cover part of side transplant bone materials. Choose the size depends on defect length.

- Three dimensional bending available, no porous exists to be able to remove the CTi-mem with simple 2nd surgery.

FootProtect the transplant material as bending inwards, have membrane fixation by contacting the existing bone.

Fixing holeThe hole formed to fix the CTi-mem to fixture. Firstly connect the CTi Spacer to fixture, lift up the CTi-mem and

then fix with the CTi Healing Abutment or CTi Cover Cap. Vertical bone formation can be decided depends on CTi

Spacer height.

1

2

3

4

5

6

CTI-mem 1

• A-Type 1wall Augmentation(Buccal or Lingual)

• B-Type 2wall Augmentation(Buccal - Proximal)

P(mm)Proximal Width

W(mm)Buccal Width

L(mm)Buccal Length Code Code

4 8 6 A1 ATMBN0810S

4 10 8 A2 ATMBN0912S

4 10 10 A3 ATMBN0915S

P(mm)Proximal Width

W(mm)Buccal Width

L(mm)Buccal Length Type Code

7 9

6 B1 ATMBN0910L

8 B2 ATMBN0912L

10 B3 ATMBN0915L

10 12

6 B4 PTMBN1210S

8 B5 PTMBN1212S

10 B6 PTMBN1215S

12 12

6 B7 PTMBN1210L

8 B8 PTMBN1212L

10 B9 PTMBN1215L

• C-Type 3wall Augmentation(Buccal - Lingual - Proximal)

P(mm)Proximal Width

W(mm)Buccal Width

L(mm)Buccal Length Type Code

7 9

6 C1 ATMLN0910L

8 C2 ATMLN0912L

10 C3 ATMLN0915L

10 12

6 C4 PTMLN1210S

8 C5 PTMLN1212S

10 C6 PTMLN1215S

12 12

6 C7 PTMLN1210L

8 C8 PTMLN1212L

10 C9 PTMLN1215L

CTi-mem

CTI mem 02

• D-Type ITI Type(Non-Fixed) 1wall Augmentation

P(mm)Proximal Width

W(mm)Buccal Width

L(mm)Buccal Length Code Code

7 9

6 D1 ATUBN0910L

8 D2 ATUBN0912L

10 D3 ATUBN0915L

• E-Type Universal Type(Submerged & Non-Fixed)

P(mm)Proximal Width

L(mm)Buccal Length Type Code

12 15 E1 CTM1215

12 20 E2 CTM1220

15 20 E3 CTM1520

• EB CTi SpacerType Diameter Hight(mm) Code

Narrow Ø3.5

1 ENCTS3710

1.5 ENCTS3715

2 ENCTS3720

Regular Ø4.0

1 ERCTS4010

1.5 ERCTS4015

2 ERCTS4020

Wide(3i) Ø5.0

1 EICTS5010

1.5 EICTS5015

2 EICTS5020

Wide(Branemark) Ø5.0

1 EBCTS5010

1.5 EBCTS5015

2 EBCTS5020

• D-Type ITI Type(Non-Fixed) 2wall Augmentation

P(mm)Proximal Width

W(mm)Buccal Width

L(mm)Buccal Length Type Code

10 12

6 D4 PTUBN1210S

8 D5 PTUBN1212S

10 D6 PTUBN1215S

Hight

Diameter

CTi-mem

CTI mem 03

CTi-mem

• Astra SpacerFixture Size Diameter Hight(mm) Code

Ø3.0(Yellow) Ø3.5

0.5 ASCTS1405

1.0 ASCTS1410

1.5 ASCTS1415

2.0 ASCTS1420

Ø3.5 / Ø4.0(Aqua) Ø4.0

0.5 ASCTS1605

1.0 ASCTS1610

1.5 ASCTS1615

2.0 ASCTS1620

Ø4.5 / Ø5.0(Lilac) Ø4.0

0.5 ASCTS2005

1.0 ASCTS2010

1.5 ASCTS2015

2.0 ASCTS2020

• Zimmer SpacerFixture Size Diameter Hight(mm) Code

Taper Screw-Vent.Screw-Vent

Plateform Ø3.5 FixtureØ3.5

0.5 ZSVCTS3505

1.0 ZSVCTS3510

1.5 ZSVCTS3515

2.0 ZSVCTS3520

Taper Screw-Vent.Screw-VentPlateform

Ø3.5 / Ø4.5 Fixture

Ø4.5

0.5 ZSVCTS4505

1.0 ZSVCTS4510

1.5 ZSVCTS4515

2.0 ZSVCTS4520

Taper Screw-VentPlateform

Ø5.7 FixtureØ5.7

0.5 ZSVCTS5705

1.0 ZSVCTS5710

1.5 ZSVCTS5715

2.0 ZSVCTS5720

• IS CTi Spacer

Diameter Hight(mm) Code

Ø4.0

0.5 ISCTS4005

1 ISCTS4010

1.5 ISCTS4015

2 ISCTS4020

Hight

Diameter

Hight

Diameter

Hight

Diameter

CTI mem 04

CTi-mem

• CTi Cover Cap

Diameter Hight(mm) Code

Ø4.0 1.5 CTC40

• Dentsply SpacerFixture Size Diameter Hight(mm) Code

Ø3.0 Fixture Ø3.0

0.5 XIVECTS3005

1.0 XIVECTS3010

1.5 XIVECTS3015

2.0 XIVECTS3020

Ø3.4 Fixture Ø3.4

0.5 XIVECTS3405

1.0 XIVECTS3410

1.5 XIVECTS3415

2.0 XIVECTS3420

Ø3.8 / Ø4.5 / Ø5.5 Fixture Ø4.5

0.5 XIVECTS4505

1.0 XIVECTS4510

1.5 XIVECTS4515

2.0 XIVECTS4520

• CTi Healing Abutment

Diameter 1(Ø) Diameter 2(Ø) Hight(mm) Code

Ø4.0

Ø4.03.0 CHAG404030

4.0 CHAG404040

Ø5.03.0 CHAG405030

4.0 CHAG405040

* Only for Xive

Hight

Hight

Diameter

Diameter 1

Diameterv2

Hight

Diameter

CTI mem 05

CTi-mem

• CTi-mem Contouring plier

• CTi Cover Cap Driver

• CTi Guage

Code MCCD

Code MG00

Code MCCP

Customized Titanium MembraneC

ustomized

Titanium M

emb

rane

159

User Guide

1. Finish the implantation of the Fixture.

2. Choose CTi-Mem by using the measurement from CTi gauge and length space of bone graft.

3. Combine the membrane healing post with the fixture. By selecting the post, you need to know the

system of the implant, volume of the bone graft and EB and IS implant have two types of height(1mm,

1.5mm, 2mm) which this information can give good selection.

4. Proceed Bone graft.

5. Make model of the selected CTI- Mem. Do not bend rapidly in the same area or it will fracture the

CTI- Mem.

6. Stable the CTI-Mem and combine the membrane healing cap or membrane cover cap with below 10 Ncm. - With the gum height use suitable healing cap.

- Use cover cap for 2nd stage surgery.

7. Suture the Soft tissue.

1. A type : 1 wall augmentation

Placement for buccal in bone defect area

Implant at the area of bonedefect

Combine CTi Spacer withimplant

Image of CTi Spacer withimplant

Bone graft at Bone defect area

Bend Cti-mem with Con-touring plier

Bend Suitable Form byBending CTi-mem

Place the mount at CTi Spacer Before suture, combine CTiHealing abutment or CTiCover cap with CTi-mem

Customized Titanium Membrane

160

Custom

ized Titanium

Mem

brane

User Guide

2. B type : 2 wall augmentation

Placement for buccal, proximal in bone defect area

3. C type : 3 wall augmentaion

Placement for buccal, proximal and lingual in bone defect area

Implant at the area of bonedefect

Combine CTi Spacer withimplant

Image of CTi Spacer withimplant

Bone graft at Bone defect area

Bend Cti-mem with Con-touring plier

Bend Suitable Form byBending CTi-mem

Place the mount at CTi Spacer Before suture, combine CTiHealing abutment or CTiCover cap with CTi-mem

Implant at the area of bonedefect

Combine CTi Spacer withimplant

Image of CTi Spacer withimplant

Bone graft at Bone defect area

Bend Cti-mem with Con-touring plier

Bend Suitable Form byBending CTi-mem

Place the mount at CTi Spacer Before suture, combine CTiHealing abutment or CTiCover cap with CTi-mem

Customized Titanium MembraneC

ustomized

Titanium M

emb

rane

161

User Guide

4. D type : 1 wall agumentation for ITI type

Placement for buccal in bone defect area

5. D type : 2 wall agumentation for ITI type

Placement for buccal and proximal in bone defect area

Detect the area of bone defect Combine cover screw orhealing abutment

Bone graft at Bone defect area Bend Cti-mem with Contouringplier

Bend Suitable Form by BendingCTi-mem

Before suture, place CTi -memat bone defect area

Detect the area of bone defect Combine cover screw orhealing abutment

Bone graft at Bone defectarea

Bend Cti-mem with Contouringplier

Bend Suitable Form by BendingCTi-mem

Before suture, place CTi -memat bone defect area

Customized Titanium Membrane

162

Custom

ized Titanium

Mem

brane

User Guide

6. E type : Non-fixed Submerged

Placement for large bone defect area

1. Practitioners should use after fully understand the handling and precautions of the product.

2. Since the product is supplied as sterile, CTi-mem should be used immediately after it is opened from

the package.

3. In the case of package is damaged, the condition of sterilization is likely to be damaged. Therefore, it

needs to be discarded.

4. Inadvertent exposure by a carelessness of suture can cause a redness, swelling and tissue to be

eliminated. Therefore, it needs to be removed.

5. Improper selection of patients or procedures can lead to a failure of treatment.

6. CTi-mem is a disposable single- use product. Do not reuse.

�Warning

Detect the area of bone defect Combine cover screw orhealing abutment

Bone graft at Bone defect area Bend Cti-mem with Contouringplier

Bend Suitable Form by BendingCTi-mem

Before suture, place CTi -memat bone defect area

Customized Titanium MembraneC

ustomized

Titanium M

emb

rane

163

CTi-mem Selection

1. Depends on the wall situation, choose A, B, C type from the CTi-men.

2. Proximal width (p) of Occlusal part that needs to be covered by Membrane is measured in oral with

determination of the 'p' size. If Proximal defect is not existed, amputate the proximal when it's 1wall

choose A, and when it's b-l defect choose C for the amputation.

3. W (Buccal Width) can be decided by P (Proximal Width) and P can be measured From B and C.

New CTi-memNew CTi-mem provides �xing holes to give smoother access for �xing screws!

Bending Portion

Lateral Cover

Fixing Hole

Proximal Finger

ProximalFinger

Additional Finger

Fixing Hole

Lateral ThicknessForming Part

SpacerAfter connecting to the �xture, mount CTi-memon spacer and have statined using Cover Screw

Tent Screw

Fixing Screw

Mount CTi-mem on a statined Tent Screw and fasten using Cover Screw

After bending or customizing, the CTi-mem,tighten the �xing screw into the foot �xing hoel

• New CTi-mem Spec

[NA3] ATMBN0915SF [NB9] PTMBN1215LF [NC9] PTMLN1215LF [NE1] CTM1215F

[NE2] CTM1220F [NE3] CTM1520F [NE4] CTM2023F [NE5] CTM25F

12mm

10mm

12mm

20mm

12mm

20mm

15mm

20mm

23mm

20mm

30mm

12mm

10mm

12mm

15mm

12mm

4mm

11mm

10mm

CTI mem 06

New CTi-mem applicationguide

Fix the Tent Screw at a defect area Choose the New CTi-mem(NE5) Tighten the Fixing Screw into each side-foot Fixing hole

Make hole Tent Screw

Tighten the Fixing Screw into the rest of Fixing holes

Bone graft Tighten the New CTi-mem with Tent Screw by using Cover Screw

Complete the New CTi-mem with bone grafting by using Tent Screw and Fixing screw

Ti-mesh(Neo Titanium Mesh)New Ti-mesh can be trimmed which ever form. Thickness 0.085mm / Hole size 0.8

• Type Of Ti-mesh

Size Code Code

20 x 12 T1 TMN 122008

25 x 20 T2 TMN 202508

35 x 25 T3 TMN 253508

50 x 35 T4 TMN 355008

15mm

20mm

25mm

25mm

12mm 25mm

35mm 35mm

CTI mem 07


Recommended