1.
12D
NOTES:
3.
12D
4
1B1
12D
CODES/STANDARDS-CSA-CMVSS265
265
DRAWING NO.
12D
FEATURE
ELECTRICAL SYSTEM 30 AMP
265
AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PER CODEREQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE 8343 OR108046 AND SCREW G67-XX-XXX OR G56-XX-XXX AS APPROPRIATEFOR INSTALLATION.
300893-15
2.
CODES/STANDARDS USA
ALL 110V WIRE ARE TO BE CLAMPED WITH CLAMP 10497-05-000WITHIN 200MM OF OUTLET BOXES, USE SCREW G67-10-12U.
-----300893-01
5
1B1
SEE GENERATOR INSTL FOR ADDITIONAL INFORMATION.
1B1
SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.
300893-11
ALL GROUND WIRES TO BE COVERED WITH TUBING 8041-02-000.
6 WIRES ROUTED THROUGH FLOOR IN THIS AREA.
5GENERATOR CABLE ASMTO GENERATOR RECEPTACLE
6
6
GENERATOR CABLEASM TO GENERATOR 54
RCP-2 (BLU)EXTERIOR
GROUND WIRE FROMLOAD CENTER TOCHASSIS GROUND BOLT
4
GENERATOR CABLE ASMTO GENERATOR
33F
GEN-3.6KW ONAN LP MICROQUIET
GEN-3.2 KW ONAN DIESEL
52G
33F
52G 5
POWER CORDBOX ASM(REF)4
AA
VIEW AA
GENERATOR CABLE
55 93
CLAMP10497-10-000 (2)SCREWG11-10-12U (2)
CLAMP10497-01-000SCREWG11-10-12U
110V CONNECTORS (4)(REF)
INVERTER(REF)SCREWG39-10-16U (4)
4
4
6
4
THROW IN WIRE #4
THROW IN WIRE #5
4
6
3
UNSPECIFIED TOLERANCES: MATERIAL:
C
D
1
TWO-PLACE (X.XX)
DSNR:
DESCRIPTION:
8
2
B
ALL DIMENSIONS ARE IN MILLIMETERSDFTR:
6
A
6
FIRST USED:
A
REV
WHOLE DIM (X)
D
REF:
8
ITEM/PART NO:
4
WEIGHT: (LBS)
SHEET:
7
B
2
4
REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES
ANGLE
5
5
13
COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC.
ONE-PLACE (X.X)
C
7
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
WIRING INSTL-BODY,110V
1 OF 4 000154951 / 30089301000
3
1.5
0.50
1
19-Sep-2016
1B1
12D
CODES/STANDARDS USA
1B1
265 CODES/STANDARDS-CSA/CMVSS
ELECTRICAL SYSTEM 30 AMP
265
TO RIGHT SIDE
110V (WHT)TO WATER HEATER
RCP-2 (BLU)BATH
4
12D
RCP-2 (BRN-2)BED LEFT
RCP-2 (BRN-2)LOUNGE
RCP-B (BRN-2)BED
4
NOTES:
AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PER CODEREQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE 8343 OR108046 AND SCREW G67-XX-XXX OR G56-XX-XXX AS APPROPRIATEFOR INSTALLATION.
1.
ALL WIRING TO BE SECURED WITHIN 200MM OF OUTLET BOXES.2.
ALL GROUND WIRES TO BE COVERED WITH TUBING 8041-02-000.3.
WIRE ROUTED IN SIDEWALL.
RCP-2 (BRN-2)TV PREP
THROW IN WIRE #2
FROM SIDEWALL
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000WIRING INSTL-BODY,110V
000154951 / 30089301000 2 OF 419-Sep-2016
1. 1B1
3. CODES/STANDARDS-CSA/CMVSS265
ELECTRICAL SYSTEM 30 AMP12D
CODES/STANDARDS USA1B1
265
ALL GROUND WIRES TO BE COVERED WITH TUBING 8041-02-000.
AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PER CODEREQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE 8343 OR108046 AND SCREW G67-XX-XXX OR G56-XX-XXX AS APPROPRIATEFOR INSTALLATION.
2.
12D
7
6
NOTES:
(BRN-2) 5500 DROP AND(BLU) 5300 DROP TO LEFT SIDE.
WIRE ROUTED IN SIDEWALL.
4
ALL WIRING TO BE SECURED WITHIN 200MM OF OUTLET BOXES.
LOCATE REFRIGERATOR RCP SO THAT RCP IS ACCESSIBLEFROM REFRIGERATOR VENT ANDD AWAY FROM REFRIGERATORCOILS. SECURE REFRIGERATOR POWER CORD AWAY FROM COILSUSING WIRE TIE.
8
8
4LOAD CENTER/ATS ASM194814-02-000
WIRE ASM-110VTO LEFT SIDE
6
110V (BLU)THROUGH FLOORTO RCP-EXTERIOR
LOAD CENTERGROUND CABLETO GROUND BOLTON FRAME RAIL
EMS(REFERENCE)4
6
LEAVE WIRES ABOVE FLOOR AND CONNECT BRN AND BRN-2110V CONNECTORS TOGETHER WITH OPTION
540A
GFI-1 US (BLU)GALLEY
GFI-1 CA (BLU)GALLEY
110V (BRN,BRN-2)THROUGH FLOORTO INVERTER5
RCP-1 (BLK-2)MICROWAVE
RCP-2 (BRN-2)SAT PREP
RCP-2 (BRN-2)BED RIGHT
RCP-3 (YEL)REFRIGERATOR
RCP-2 (BLU)GALLEY
RCP-B (BRN)ROOF
RCP-B (RED)ROOF
7
SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.INVERTER-DC/AC WITHOUT40A
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000WIRING INSTL-BODY,110V
000154951 / 30089301000 3 OF 419-Sep-2016
GENERATOR
ROOF AIRCONDITIONER
RCP-GFIGALLEY
POWER CORDRCP BOX
POWERCORDASM
1
RCP-REFRIGERATOR
4RCP-BLANKROOF
5
JUNCTIONBOX
RCP-BATH
RCP-EXTERIOR
RCP-GALLEY
NOTES:
2
1 ALL WIRES DOWN STREAM AND INCLUDING THIS OUTLETARE GROUND FAULT CIRCUIT INTERRUPT PROTECTED.
WIRE ROUTED THRU FLOOR.
WIRE ROUTED IN SIDEWALL.3
WIRE ROUTED IN ROOF.4
SEE MANUFACTURERS DIAGRAM.5
2
WATERHEATER
LINE IN
EMS RELAY(LOCATED UNDERGALLEY CABT)
PRIORITY LOAD
SHED LOAD
5
5
14-2
14-2 14-2
12-212-2
10-2
10-2 10-2
110V CONNECTOR(BELOW FLOOR)
THROW IN WIRE #5
110V CONNECTOR(BELOW FLOOR) 5
INVERTER
THROW IN WIRE #4BRN-2
CODES/STANDARDS USA
CODES/STANDARDS-CSA/CMVSS
ELECTRICAL SYSTEM 30 AMP
12D2651B1
1B1
265
12D
2015 20 151530 15
RCP-CONVERTER
6
GROUNDLUG
8-GRNLOAD CENTER
WIRE AND RECEPTACLE SUPPLIED INTREGRATEDINTO LOAD CENTER DISTRIBUTION PANEL.
6
WHT
RCP-MICROWAVE
BLK-2
RCP-BLANKBED
RCP-LOUNGE
RCP-BED RIGHT
RCP-BED LEFT
3
RCP-BLANKROOF
RCP-SAT PREP
3
4
RCP-TV PREP
THROW IN WIRE #2RCP-
MICROWAVE
53B
WTR HTR TKLS W/RECIRCUL PUMP1BU
WTR HTR-6GAL ELECTRIC/LP GAS
1BU
53B
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000WIRING INSTL-BODY,110V
000154951 / 30089301000 4 OF 419-Sep-2016