BSSPAR1: Chapter 9Dual Band Features

Page 2: 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02

7/17/2019 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02

http://slidepdf.com/reader/full/09-rn2010en20gln00dualbandfeaturesv1-141011075036-conversion-gate02 2/12

2 © Nokia Siemens Networks 

Legal Notice

Intellectual Property Rights

 All copyrights and intellectual property rights for Nokia Siemens Networks training documentation, productdocumentation and slide presentation material, all of which are forthwith known as Nokia Siemens Networkstraining material, are the exclusive property of Nokia Siemens Networks . Nokia Siemens Networks owns therights to copying, modification, translation, adaptation or derivatives including any improvements ordevelopments. Nokia Siemens Networks has the sole right to copy, distribute, amend, modify, develop,license, sublicense, sell, transfer and assign the Nokia Siemens Networks training material.

Individuals can use the Nokia Siemens Networks training material for their own personal self-developmentonly, those same individuals cannot subsequently pass on that same Intellectual Property to others without

the prior written agreement of Nokia Siemens Networks .

The Nokia Siemens Networks training material cannot be used outside of an agreed Nokia Siemens Networkstraining session for development of groups without the prior written agreement of Nokia Siemens Networks.

Page 3: 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02

7/17/2019 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02

http://slidepdf.com/reader/full/09-rn2010en20gln00dualbandfeaturesv1-141011075036-conversion-gate02 3/12

3 © Nokia Siemens Networks 

Module Objectives

• Explain how additional frequency bands are taken into use in a dual

band network• Describe shortly the architecture of a dual band network

• Explain in detail the direct access to desired layer / band mechanism(DADL/B)

Page 4: 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02

7/17/2019 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02

http://slidepdf.com/reader/full/09-rn2010en20gln00dualbandfeaturesv1-141011075036-conversion-gate02 4/12

4 © Nokia Siemens Networks 

890-915 MHz 935-960 MHz

1710-1785 MHz 1805-1880 MHz

BSC Supports: GSM 900/1800 (Europe/ETSI) or GSM 800/1800 or GSM 800/1900 (USA/ANSI)

Usually lower signal level for GSM 1800 cell-> MS camps on GSM 900 cell-> must be set less attractive-> or MS must be handed over to GSM 1800 cell

BTS equipment

Flexi, Ultra, Metro, Talk, Insite

Capacity Expansion(Dual Band)

Note! RG20 feature Merged P-& E-GSM900

Page 5: 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02

7/17/2019 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02

http://slidepdf.com/reader/full/09-rn2010en20gln00dualbandfeaturesv1-141011075036-conversion-gate02 5/12

5 © Nokia Siemens Networks 

890-915 MHz 935-960 MHz

Classical GSM 900 (P-GSM) + Extended GSM 900 (E-GSM)

PGSM and EGSM band can be configured and used in the same BTS object (requires thatCommon BCCH option is active)

880-890

925-935

E E PP

Capacity Expansion(Tri Band)

Page 6: 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02

7/17/2019 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02

http://slidepdf.com/reader/full/09-rn2010en20gln00dualbandfeaturesv1-141011075036-conversion-gate02 6/12

6 © Nokia Siemens Networks 

Capacity ExpansionMS Capability indication

• MS indicates its frequency band capabilities and power capabilities in MSClassmark3 information element

• Information made available to BSS:

• During call setup : Classmark Change message

• Inter-BSS handover: Handover Request message from MSC

• Intra-BSS handover: BSS maintains the information

Page 7: 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02

7/17/2019 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02

http://slidepdf.com/reader/full/09-rn2010en20gln00dualbandfeaturesv1-141011075036-conversion-gate02 7/127 © Nokia Siemens Networks 

Handover for multi vendor equipment

Nokia GSM 900 <-> Nokia GSM 900Nokia GSM 900 <-> Nokia GSM 1800Nokia cell <-> other GSM 900 cell (controlled byMSC)

900 1800

Dual band MS

900

NSN BSS

MSC

other BSS

900

DX 200

CM3 

Parameter  

multiBandCell (DBC) Y/N indicates cell as dual band cellmultiCellBandReporting (MBR) 0..3 number of adjacent dual band cells taken

into account for measurement reportearlySendingIndication (ESI) Y/N enables MS to send classmark 3 message

as early as possible

Capacity Expansion(Dual Band Network Operation)

Page 8: 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02

7/17/2019 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02

http://slidepdf.com/reader/full/09-rn2010en20gln00dualbandfeaturesv1-141011075036-conversion-gate02 8/128 © Nokia Siemens Networks 

Traffic Management

C2 ParameterDirect Access to

Desired Layer/BandUmbrella or

PBGT handover

 Adjacent Cell Priorities& Load Factors

 AdvancedMultilayer

Handling (AMH)

FMMS Detect

Idle Mode Call Setup Dedicated mode

Page 9: 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02

7/17/2019 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02

http://slidepdf.com/reader/full/09-rn2010en20gln00dualbandfeaturesv1-141011075036-conversion-gate02 9/129 © Nokia Siemens Networks 

DADL/BFunctionality

900 Macro

900 Micro

1800

TCH allocation during call set up (SDCCH handover)

HighestPriority

2nd priority 2nd priority

3rd priority

MS camped on 900microcell

MS camped on 900macrocell

900 Micro

1800

HighestPriority

• Only Intra-BSC DADL/B handovers possible

• Queuing is not allowed for DADL/B handover

Page 10: 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02

7/17/2019 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02

http://slidepdf.com/reader/full/09-rn2010en20gln00dualbandfeaturesv1-141011075036-conversion-gate02 10/1210 © Nokia Siemens Networks 

cell load = 100 %

Btsloadthreshold <cell load < 100 %

Cell load <=btsloadthreshold

DR initiatedwith / withoutqueuing

DADL/B

initiated

TCH allocated

from serving

cell

DADL/BTriggering

MO

Class 

Abbreviated

Name 

Range And Step  Description  Default

value 

BSC - MML

Name 

 ADCE dadlbTargetC

ell

Y, N Indicates the cell as a potential target for DADL/B. N DADL

BTS btsLoadThres

hold

0...100 %, step 1 % Threshold for the BTS to be considered overloaded to

trigger a HO from SDCCH to the TCH of other band

70% BLT

Page 11: 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02

7/17/2019 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02

http://slidepdf.com/reader/full/09-rn2010en20gln00dualbandfeaturesv1-141011075036-conversion-gate02 11/1211 © Nokia Siemens Networks 

Estimation of RX levels of adjacent DADL/B target cells

Ranking of adjacent cells as usual on the basis of

hoPriorityLevel, hoLoadFactor , btsLoadThreshold 

Check of adjacent cells with condition AV_RXLEV_NCELL > hoLevelUmbrella 

 Adjacent DADL/B cell with sufficient RX level

Yes No

DADL/B handover See next slide

Cell load exceeds btsLoadThreshold during call set up butnot 100 %

DADL/B(Execution)

Page 12: 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02

7/17/2019 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02

http://slidepdf.com/reader/full/09-rn2010en20gln00dualbandfeaturesv1-141011075036-conversion-gate02 12/12

12 © Nokia Siemens Networks 

Neighbour cell reporting 

DADL/B 

triggered 

MinTimeLimitDR 

DADL/B handover  

success 

DADL/B handover  

failure 

DADL/B handover  

candidate selection fails 

TCH allocated from DADL/B 

target cell 

MaxTimeLimitDR 

TCH allocation from 

serving cell 

Serving cell in real TCH congestion. DR attempt with or without queuing 

Maximum allowed time for  

DADL/B handover expires 

Time 

TCH allocation from 

serving cell 

Serving cell in real TCH congestion. 

DR attempt with or without queuing 

DADL/B uses same

timers as directed

retry 

DADL/BTiming


Recommended