BSSPAR1: Chapter 9Dual Band Features
7/17/2019 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02
http://slidepdf.com/reader/full/09-rn2010en20gln00dualbandfeaturesv1-141011075036-conversion-gate02 2/12
2 © Nokia Siemens Networks
Legal Notice
Intellectual Property Rights
All copyrights and intellectual property rights for Nokia Siemens Networks training documentation, productdocumentation and slide presentation material, all of which are forthwith known as Nokia Siemens Networkstraining material, are the exclusive property of Nokia Siemens Networks . Nokia Siemens Networks owns therights to copying, modification, translation, adaptation or derivatives including any improvements ordevelopments. Nokia Siemens Networks has the sole right to copy, distribute, amend, modify, develop,license, sublicense, sell, transfer and assign the Nokia Siemens Networks training material.
Individuals can use the Nokia Siemens Networks training material for their own personal self-developmentonly, those same individuals cannot subsequently pass on that same Intellectual Property to others without
the prior written agreement of Nokia Siemens Networks .
The Nokia Siemens Networks training material cannot be used outside of an agreed Nokia Siemens Networkstraining session for development of groups without the prior written agreement of Nokia Siemens Networks.
7/17/2019 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02
http://slidepdf.com/reader/full/09-rn2010en20gln00dualbandfeaturesv1-141011075036-conversion-gate02 3/12
3 © Nokia Siemens Networks
Module Objectives
• Explain how additional frequency bands are taken into use in a dual
band network• Describe shortly the architecture of a dual band network
• Explain in detail the direct access to desired layer / band mechanism(DADL/B)
7/17/2019 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02
http://slidepdf.com/reader/full/09-rn2010en20gln00dualbandfeaturesv1-141011075036-conversion-gate02 4/12
4 © Nokia Siemens Networks
890-915 MHz 935-960 MHz
1710-1785 MHz 1805-1880 MHz
BSC Supports: GSM 900/1800 (Europe/ETSI) or GSM 800/1800 or GSM 800/1900 (USA/ANSI)
Usually lower signal level for GSM 1800 cell-> MS camps on GSM 900 cell-> must be set less attractive-> or MS must be handed over to GSM 1800 cell
BTS equipment
Flexi, Ultra, Metro, Talk, Insite
Capacity Expansion(Dual Band)
Note! RG20 feature Merged P-& E-GSM900
7/17/2019 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02
http://slidepdf.com/reader/full/09-rn2010en20gln00dualbandfeaturesv1-141011075036-conversion-gate02 5/12
5 © Nokia Siemens Networks
890-915 MHz 935-960 MHz
Classical GSM 900 (P-GSM) + Extended GSM 900 (E-GSM)
PGSM and EGSM band can be configured and used in the same BTS object (requires thatCommon BCCH option is active)
880-890
925-935
E E PP
Capacity Expansion(Tri Band)
7/17/2019 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02
http://slidepdf.com/reader/full/09-rn2010en20gln00dualbandfeaturesv1-141011075036-conversion-gate02 6/12
6 © Nokia Siemens Networks
Capacity ExpansionMS Capability indication
• MS indicates its frequency band capabilities and power capabilities in MSClassmark3 information element
• Information made available to BSS:
• During call setup : Classmark Change message
• Inter-BSS handover: Handover Request message from MSC
• Intra-BSS handover: BSS maintains the information
7/17/2019 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02
http://slidepdf.com/reader/full/09-rn2010en20gln00dualbandfeaturesv1-141011075036-conversion-gate02 7/127 © Nokia Siemens Networks
Handover for multi vendor equipment
Nokia GSM 900 <-> Nokia GSM 900Nokia GSM 900 <-> Nokia GSM 1800Nokia cell <-> other GSM 900 cell (controlled byMSC)
900 1800
Dual band MS
900
NSN BSS
MSC
other BSS
900
DX 200
CM3
Parameter
multiBandCell (DBC) Y/N indicates cell as dual band cellmultiCellBandReporting (MBR) 0..3 number of adjacent dual band cells taken
into account for measurement reportearlySendingIndication (ESI) Y/N enables MS to send classmark 3 message
as early as possible
Capacity Expansion(Dual Band Network Operation)
7/17/2019 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02
http://slidepdf.com/reader/full/09-rn2010en20gln00dualbandfeaturesv1-141011075036-conversion-gate02 8/128 © Nokia Siemens Networks
Traffic Management
C2 ParameterDirect Access to
Desired Layer/BandUmbrella or
PBGT handover
Adjacent Cell Priorities& Load Factors
AdvancedMultilayer
Handling (AMH)
FMMS Detect
Idle Mode Call Setup Dedicated mode
7/17/2019 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02
http://slidepdf.com/reader/full/09-rn2010en20gln00dualbandfeaturesv1-141011075036-conversion-gate02 9/129 © Nokia Siemens Networks
DADL/BFunctionality
900 Macro
900 Micro
1800
TCH allocation during call set up (SDCCH handover)
HighestPriority
2nd priority 2nd priority
3rd priority
MS camped on 900microcell
MS camped on 900macrocell
900 Micro
1800
HighestPriority
• Only Intra-BSC DADL/B handovers possible
• Queuing is not allowed for DADL/B handover
7/17/2019 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02
http://slidepdf.com/reader/full/09-rn2010en20gln00dualbandfeaturesv1-141011075036-conversion-gate02 10/1210 © Nokia Siemens Networks
cell load = 100 %
Btsloadthreshold <cell load < 100 %
Cell load <=btsloadthreshold
DR initiatedwith / withoutqueuing
DADL/B
initiated
TCH allocated
from serving
cell
DADL/BTriggering
MO
Class
Abbreviated
Name
Range And Step Description Default
value
BSC - MML
Name
ADCE dadlbTargetC
ell
Y, N Indicates the cell as a potential target for DADL/B. N DADL
BTS btsLoadThres
hold
0...100 %, step 1 % Threshold for the BTS to be considered overloaded to
trigger a HO from SDCCH to the TCH of other band
70% BLT
7/17/2019 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02
http://slidepdf.com/reader/full/09-rn2010en20gln00dualbandfeaturesv1-141011075036-conversion-gate02 11/1211 © Nokia Siemens Networks
Estimation of RX levels of adjacent DADL/B target cells
Ranking of adjacent cells as usual on the basis of
hoPriorityLevel, hoLoadFactor , btsLoadThreshold
Check of adjacent cells with condition AV_RXLEV_NCELL > hoLevelUmbrella
Adjacent DADL/B cell with sufficient RX level
Yes No
DADL/B handover See next slide
Cell load exceeds btsLoadThreshold during call set up butnot 100 %
DADL/B(Execution)
7/17/2019 09 Rn2010en20gln00dualbandfeaturesv1 141011075036 Conversion Gate02
http://slidepdf.com/reader/full/09-rn2010en20gln00dualbandfeaturesv1-141011075036-conversion-gate02 12/12
12 © Nokia Siemens Networks
Neighbour cell reporting
DADL/B
triggered
MinTimeLimitDR
DADL/B handover
success
DADL/B handover
failure
DADL/B handover
candidate selection fails
TCH allocated from DADL/B
target cell
MaxTimeLimitDR
TCH allocation from
serving cell
Serving cell in real TCH congestion. DR attempt with or without queuing
Maximum allowed time for
DADL/B handover expires
Time
TCH allocation from
serving cell
Serving cell in real TCH congestion.
DR attempt with or without queuing
DADL/B uses same
timers as directed
retry
DADL/BTiming