+ All Categories
Home > Documents > Handbookforftthospv1 150225032334 Conversion Gate02

Handbookforftthospv1 150225032334 Conversion Gate02

Date post: 21-Feb-2018
Category:
Upload: pho-le
View: 223 times
Download: 3 times
Share this document with a friend

of 101

Transcript
  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    1/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 1 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    HANDBOOKHANDBOOKHANDBOOKHANDBOOK

    ForForForFor

    Outside PlantOutside PlantOutside PlantOutside Plant----Fiber to the HomeFiber to the HomeFiber to the HomeFiber to the Home

    (FTTH(FTTH(FTTH(FTTH----OSP)OSP)OSP)OSP)ForForForFor

    PT TELKOM INDONESIAPT TELKOM INDONESIAPT TELKOM INDONESIAPT TELKOM INDONESIA

    V 1.0V 1.0V 1.0V 1.0

    (June 2013)(June 2013)(June 2013)(June 2013)

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    2/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 2 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    Contents

    PART-I DESIGN & INSTALLATION ........................................................................ 4

    FTTH-OSP DESIGN PRINCIPLES .......................................................................... 5

    MATERIALS FOR FTTH-OSP (STO - ODP) .......................................................................... 7

    MATERIALS FOR FTTH-OSP (HRB: Hign-Rise Building) ......................................................... 8

    1. FEEDER CABLE DESIGN ...... 111.1 Google Map .......................................... 111.2 Skema Kabel Feeder .................. 121.3 PetaLokasi Duct & Kabel Feeder .... 15

    1.4 Sample Design of Feeder Cable Network ............... 151.5 Core Assignment Diagram ..... 191.6 General Concept for Feeder Cable Design ............... 22

    2. DISTRIBUTION CABLE DESIGN . 252.1 Google Map ..... 252.2 Skema Kabel Distribusi .. 25

    2.3 Sample Design of Distribution Cable Network ............. 282.4 Branching ODP ............ 322.5 Duct Usage for Distribution Network & Drop-core Installation (Underground) .......................... 33

    3. GENERAL CONCEPT FOR DISTRIBUTION CABLE DESIGN ............. 343.1 Duct / Buried Section ................ 343.2 Aerial Section .............................. 37

    4. CABLE RACK / OTB RACK IN STO BUILDING ... 41

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    3/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 3 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    5. HIGH-RISE BUILDING (HRB) DESIGN ......................................................................... 425.1 Materials for HRB Solution ........................................... 425.2 Design Concept for HRB Solution ................... 435.3 Type of ODC for High-Rise-Building ..... 445.4 Example of Cable Tray/Trunking ............... 455.5 Sample Design: Skema Distribusi ..... 46

    5.6 Sample Design: Peta Lokasi Distribusi ............... 47

    6. REFERENCE . 506.1 Pondasi ODC-C-144 Splitter ..... 516.2 Pondasi ODC-C-288 Splitter ..... 526.3 Pondasi ODP Pedestal & HH-PIT-60 ............... 536.4 HH-1: Dimensi Dalam (P=1700 x L=1250 x T=1300) ............... 54

    6.5 HH-2: Dimensi Dalam (P=1200 x L=600 x T=1300) .............................................................. 556.6 HH-80: Dimensi Dalam (P=800 x L=800 x T=800) .............................................................. 566.7 Installation of ODP Wall ............................................................................ 576.8 Form for Core Assignment Diagram ............................................................................ 596.9 Installation Check Sheet ............................................................................ 636.10 List of Assembly Unit Designator ............................................................................ 67

    PART-II ACCEPTANCE TESTING ........................................................................ 73

    1. TEST PROCEDURE ................................ 74

    2. OPM MEASUREMENT ......................................................................... 862.1 Application of Measurement Forms ................ 872.2 Measurement Forms .............................. 92

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    4/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 4 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    5/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 5 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    FTTH-OSP DESIGN PRINCIPLES (1)

    1. FTTH OSP Design Work (Feeder & Distribusion) shall be carried out in accordancewith the frame of this document.

    2. LINK BUDGET

    1) Descriptions in the Contract:

    The Design shall ensure the FTTH OSP System Power Budget of the GPON OLTto ONU (in the configuration of 1:4 Splitter at ODC and 1:8 Splitter at ODP) shallbe 28dB (including the margin of 3dB).

    2) Applicable Power Budget in the Project:

    Contract Requirement: 28dB - 3dB (Margin) = 25dB (ITU-T G.652D @ WaveLength 1310nm=0.35dB/km)

    Requirement by KBB: 25dB - 2dB = 23dB (including 2dB as an Additional

    Margin due to an incidental increment of the loss in OSP during an operation) Link Budget to be applied for the Project: 25dB @ 1310nm

    We may try however, to keep 23dB @ 1310nm as far as practicable.

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    6/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 6 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    FTTH-OSP DESIGN PRINCIPLES (2)

    3. FTTH OSP Design shall be composed of the following:

    3.1 Feeder Cable Design

    1) Google Map per STO

    2) Skema Kabel Feeder (Schematic Drawing)

    3) Skema Duct (Schematic Drawing)

    4) Peta Lokasi Duct & Kabel Feeder (Location Map)

    5) Special Design (MH Modification, Duct Bridge etc.)

    3.2 Distribution Cable Design

    1) Google Map per Lokasi

    2) Skema Kabel Distibusi

    3) Peta Lokasi Distribusi

    4) Special Design (HH Modification, Modified ODP Foundation etc.)

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    7/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 7 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    Feeder Cable

    DC-OF-SM-

    12D/24D/48D/

    96D/144D/288D

    ODC

    ODC-C-48/144/288 SplitterNote: ODC-C-48 = Wallmount Type

    Pass through closure Type/Designator

    for 48core Star/Ring SC-OF-SM-PT-48

    for 96core Star/Ring, 144core Star SC-OF-SM-PT-144S

    for 144core Ring SC-OF-SM-PT-144R

    for 288core Star SC-OF-SM-PT-288S

    for 288core Ring SC-OF-SM-PT-288R

    Inline closure Type/Designator

    for 12c-24c SC-OF-SM-24

    for 12c-48c SC-OF-SM-48

    for 12c-96c SC-OF-SM-96

    for 12c-144c SC-OF-SM-144

    for 12c-288c SC-OF-SM-288

    STO

    ODC

    ODP (Aerial)

    ODP-SSW-8(1:8 Splitter built-in)

    Branching ODP(Pole/Wall Mount)

    ODP-PW-BR

    Branching ODP(Pedestal)

    ODP-PL-BR

    ODP (Wall Mount)

    ODP-PW-8/16

    Distribution Cable

    (Aerial)

    AC-OF-SM-8/12/24-SC

    ODP (Pedestal)

    ODPPL-8/16

    Distribution Cable(Duct)

    DC-OF-SM-8/12/24-SC

    Passive Splitter

    PS-1-2-ODC/

    PS-1-4-ODC

    PS-1-8-ODP

    Line Guard/Suspension

    C-Clamp

    Materials for FTTH OSP (STO - ODP)

    OTB

    TC-OF-SM-

    12/24/48/72/96/144

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    8/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 8 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    Cable Trunking and Accessories

    Splitter for ODC-HRB

    PS-1-4-ODC-HRB

    Materials for FTTH-OSP (HRB: High-Rise Building)

    ODC-HRB (Cabinet)

    ODC-HRB-420

    ODC-HRB-240

    ODC-HRB-180

    ODC-HRB(Rack)

    ODC-HRB-RACK-480

    ODC-HRB-RACK-240

    ODC-HRB-RACK-120

    19 inch Rack

    TC-OF-R-19

    or

    Indoor Cable

    (1-C Low Friction)

    IC-OF-SM-1D

    ODC-HRB

    ODP-HRB

    ODP-HRB-16/32 PS-1-8-ODP-HRB

    Indoor Cable

    (2-C Low Friction)

    IC-OF-SM-2D

    ROSETTE

    RS-IN-SC-1P/

    TC-MK-SC-1P

    FUSE-CONNECT

    ISC-UPC-FD

    T-JointCable Trunking Elbow (Flat Angle)

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    9/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 9 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    LIST OF MATERIALS AND INSTALLATION MANUALS (1/2) As of: 01-June-2013No. Spec.No. Manual.No. Sub manuals

    1 - 5. ESMDDLT000*****K

    6 ESMDDLT00028824K

    7 - 8. JBT-05166A

    9 - 12. ESMDALT0000****K

    13-16 ENZDSCDLT0*****K

    17 - 20 ENZDSCALT00****K

    21-23 ESMDDLT0000****K24 JBT-05027B

    25 - 26 JBT-05026-> JBT-05391

    49 - 50 JBT-04109A

    51 - 52 JBT-04770D

    53 - 54 JBT-04109A

    55 - 56 PNJHC-1101-54-02(2.8mm)

    57 - 75 TS1211-01

    76 - 78 PNJBC-0516-54-03 PNJBC-0516-82-01 ODC-C sub manual_130214

    79 PNJBC-0516-54-04 PNJBC-0516-82-01 ODC-C sub manual_13021480-81 PNJCS-0013-54-10

    82 - 83 PNJCY-0085-54-03 PNJCY-0085-82-01 ODP-CA sub manual_130323

    84 - 87 PNJBC-0516-54-06

    88 - 89 JEMBO Pedestal + ODP-CA PNJCY-0085-82-01

    90 - 95 PNJBC-0516-54-07 PNJBC-0516-82-04 TC-SM sub manual_130225

    96 PNJBC-0470-54-04 PNJBC-0470-82-02

    97 PNJBC-0472-54-08A

    98 PNJBC-0516-54-08

    99-101 PNJBC-0516-54-09 PNJBC-0516-82-06102 - 106 PNJBC-0516-54-10

    107 - 111 PNJSC-1077-54-03Rev.1

    112 - 116 PNJBC-0516-54-11

    117 - 121 PNJSC-1077-54-04Rev.1

    200 PNJCY-0084-54-02

    201 PNJCY-0084-54-01

    202 PNJCY-0084-54-04

    203 PNJCY-0084-54-03

    204 PNJCY-0084-54-05

    Manuals will be available upon supply of the material

    Manauals not applicable

    DC-OF-SM-*D (SM.D D - LT */*T)

    DC-OF-SM-*-SC (SM.D D - LT */*T)AC-OF-SM-8-SC (OGGDE-SSW)

    Name File

    AC-OF-SM-*D (SM.D A - LT */*T)

    DC-OF-SM-*C (NZDS.C D - LT */*T)

    AC-OF-SM-*C (NZDS.C A - LT */*T)

    DC-OF-SM-288D (SM.D D - LT 288/24T)

    DC-OF-SM-*D (OG8ETSWBE)

    AC-OF-SM-*-SC (OGNM4WTGDE-SSW)

    GC-OF-SM-1D (FR-OGINE)

    HC-OF-SM-*D (FR-OGNMGDE-SSD)

    GC-OF-SM-1D (FR-OGINE)

    Patch cord (2.8mm, BIS-B)

    Pigtails and Patchcords

    ODC-C-* Splitter

    ODC-C-48 SplitterODC-CU (FSCO-HHS)

    ODP-CA-* for Pole Mount

    ODP-A-*

    ODP-PL-* (Pedestal_Box+ ODP-CA-* For_Wall_mount)

    TC-SM-*

    RS-IN-SC-1P (FPB-103A(S))

    RS-IN-SC-2P (FPB-302-2SC(PT))

    House Hook

    Cable cleat

    RS-IN-SC-4P (RS-IN-SC-4)

    TC-MK-SC-*PS-1-*-ODC (Optical Spitter Module 1 x N Type)

    PS-1-*-ODP(PLC Type 1xN Splitter)

    PS-2-*-ODC (Optical Spitter Module 2 x N Type)

    PS-2-*-ODP (PLC Type 2xN Splitter)

    Deadending Wire Vice (C clamp)

    Drop Cable Clamp (S Clamp)

    Selft-Support Wire Line Guard (Line Guard 2.6mm)

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    10/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 10 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    LIST OF MATERIALS AND INSTALLATION MANUALS 2/2) As of: 01-June-2013No. Spec.No. Manual.No. Sub manuals205 PNJCY-0084-54-06

    206 PNJCY-0084-54-07

    207 PNJCY-0084-54-08

    400 - 401 PNJHC-1101-53-01

    402 PNJCY-0067-54-18 PNJC-0067-82-04

    403 PNJHY-0001-53-11

    404 PNJHY-0001-53-10405 PNJHY-0107-53-05

    406 PNJHY-0107-54-21Rev.2 JDAA-11-12-0048D

    PNJHY-0107-54-21Rev.2 JDAA-11-13-0075

    407 PNJBC-0480-54-17

    408 PNJBC-0480-54-17

    409 PNJBC-0480-54-17

    410 B-12F0401 PNJCY-0085-82-03

    411 B-12F0401 PNJCY-0085-82-03

    412 PNJBC-0085-54-02 PNJCY-0085-82-01413 PNJBC-0085-54-02 PNJCY-0085-82-01

    414 JBT-04260B

    415 JBT-04260B

    416

    417

    418

    419

    420

    421 PNJBC-0516-54-12 PNJBC-0516-82-09A422 PNJBC-0516-54-12 PNJBC-0516-82-09A

    423 PNJBC-0516-54-12 PNJBC-0516-82-09A

    424 PNJBC-0516-54-13 PNJBC-0516-82-10

    425 PNJBC-0516-54-13 PNJBC-0516-82-11

    426 PNJBC-0527-54-07

    427 PNJBC-1077-54-03Rev.1

    Manuals will be available upon supply of the material

    PS-1-8-ODP-HRB

    ODP-HRB-16

    PS-1-4-ODC-HRB

    Pass through closureType4 ( For 288core Ring)

    ODC-HRB-420ODC-HRB-240

    ODC-HRB-180

    ODP-HRB-32

    Low Friction Indoor Cable , 2C

    Pass through closureType1 ( For 48core Star/Ring )

    Pass through closureType2 ( For 96core Star/Ring )

    Pass through closureType3 ( For 144core Ring )

    Pass through closureType4 ( For 288core Star)

    ODP-BR for Branching (3 Hole Type) , Pole mounting type

    ODP-BR for Branching (3 Hole Type) , termasuk Dome Pedestal

    ODP Outdoor/Wall , Termasuk Adaptor , Space Passive Splitter, 8 PortODP Outdoor/Wall , Termasuk Adaptor , Space Passive Splitter, 16 Port

    Low Friction Indoor Cable , 1C

    Outdoor Optical Connector Cabinet (FPB-203-*SC-A (PT)) 4 Port

    L-clamp

    Flex Band IBT-206

    BW-Clamp

    Free Bending Optical cord (3mm, BIS-B)

    Outdoor Optical Connector Cabinet (FPB-203-*SC-A (PT)) 1 Port

    Outdoor Optical Connector Cabinet (FPB-203-*SC-A (PT)) 2 Port

    ODP-SSW (FSCO-AS-SP(in/splice))

    FIELD INSTALLBLE SC CONNECTOR (FAST-SC-SM-09/CO)

    FIELD INSTALLBLE SC CONNECTOR (FAST (N) -SC-SM-UNI/GT)FUSION CONNECTOR (Fuseconnect-SC-SF-SM-20/30)

    FUSION CONNECTOR (Fuseconnect-SC-DC) for Drop cable

    FUSION CONNECTOR (Fuseconnect-SC-LF) for LowFriction cable

    Name File

    Manauals not applicable

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    11/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 11 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    1. FEEDER CABLE DESIGN

    A. The Feeder Cable Route shall be planned to utilize the existing duct route asthe first priority so as to minimize the road excavation length.

    B. The capacity of Feeder Cables designed/implemented by the previousTOS/PO as well as for the followings shall be taken into account at theFeeder Cable Capacity Planning:

    1) AL PRO: Existing Facility such as MSAN, RK, etc.

    2) Node B Project

    3) GDI: Government Digitalization Network

    1.1 GOOGLE MAP1) Nama STO: legend berbentuk Rumah (Warna Merah)

    2) Route Feeder: warna Merah3) Nama ODC sesuai dengan Lokasi/Cluster

    4) Kapasitas ODC/ Jumlah Homepass

    5) Boundary ODC/Lokasi/Cluster dg Boundary Area Potensi

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    12/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 12 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    1.2 SKEMA KABEL FEEDER

    Purpose: Information required for the Feeder Cable Work

    A. OTB at STO

    OTB to be installed with the symbol Telkom Standard and indicated with the designator in BoQ:

    Example: TC-OF-SM-xx (yy)

    B. Feeder CableIndication: Black Line (New: 0.6 point, Existing: 0.3 point)

    Information:

    1) Type (Duct/Aerial) and capacity of cable

    2) Length of cable

    3) Core Assignment

    Note: The younger core number shall be assigned for the far end (the last position) and

    spare cores (Cadangan).

    Total Quantity of OTB

    Type of OTB

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    13/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 13 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    IDENTIFICATION OF FEEDER CABLE

    FE XXX 01-01-01 (01-288)

    Core No. In Cable

    Segment No.

    Feeder No.

    Code STOCode Feeder Cable

    DC-OF-SM-XXX-xxxxM

    Cable Length

    in meter

    No. Of Cores

    Type of Cable

    Duct Cable: DC-OF-SM

    Aerial Cable: AC-OF-SM

    Branch-Segment No.

    Note:

    Cable Line:

    New: Tebal (e.g. 6pt.)

    Existing: Tipis (e.g. 3pt.)

    Identification:

    New: Bold FontExistiong: Normal Font

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    14/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 14 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    C. ODC

    D. MH/HH/CLOSURE

    1) MH/HH: Name of Existing MH/HH or Type of New MH/HH

    2) Closure:

    a. Straight Joint: SC-OF-SM-xxx

    b. Pass-through Joint: SC-OF-SM-xxx-PT

    ODC Capacity

    ODC No. FA, FB, .......

    Code STO

    Code ODC

    xx PS 1:4 (xxx HP)

    Number of Homepass

    Code Splitter 1:4

    Number of Splitter 1:4

    Coordinates Lokasi ODC

    ODC-XXX-FA-288

    ( - )Assigned core to be

    terminated

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    15/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 15 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    1.4 SAMPLE DESIGN OF FEEDER CABLE NETWORK

    1.3 PETA LOKASI DUCT & KABEL FEEDER Purpose: Information required for the Civil Work shall be plot on the scaled map

    1) SKEMA DUCT

    (Refer to 1.4.1)

    2) SKEMA KABEL FEEDER

    (Refer to 1.4.2)

    3) PETA LOKASI

    KABEL FEEDER

    (Refer to 1.4.3)

    Lokasi CC

    ODC-ABC-F-288

    STO

    ABC

    24

    15.0ABC

    01/01

    ABC

    01/02

    ABC

    01/03

    ABC

    01/xx

    ABC

    01/yy

    6 6

    6

    6

    4

    ABC

    02/02

    ABC02/01

    ABC

    02/xx

    100.0 100.0

    100.0

    100.0

    100.0

    HH-2

    HH-

    80

    DD-BM-HDPE-1

    35.0

    HH-1

    HH-1

    DD-BM-HDPE-1

    150.0

    DD

    -BM-HDPE-BIG-1

    DD-BM-

    HDPE-

    BIG-1

    150.0

    bbb.

    0

    Lokasi AA

    ODC-ABC-F-144

    Lokasi BB

    ODC-ABC-F-288

    Lokasi DD

    ODC-ABC-F-144

    JL

    JL

    JL

    aaa.0

    DD-BM-

    HDPE-

    BIG-1

    HH-1Ca

    bles

    lac

    k(10)sha

    llbeprov

    ide

    da

    t

    every

    1000m

    ofcab

    leleng

    th.

    (Incase

    ofDD-B

    M-H

    DPE

    ,HH

    -1/2s

    ha

    llbe

    ins

    talle

    d.)

    Legend:: Assigned Duct for New Cable

    : Vacant Duct: Occupied Duct

    Lokasi CC

    ODC-ABC-F-288

    xx PS 1:4 (yyHP)(241-288)

    xxx.xxxxE yyy yyy.yyyy

    Lokasi DD

    ODC-ABC-F-144

    xx PS 1:4 (yyHP)(217-240)

    xxx.xxxxE yyy yyy.yyyy

    Lokasi AA

    ODC-ABC-F-144

    xx PS 1:4 (yyHP)(121-144)

    xxx.xxxxE yyy yyy.yyyy

    Lokasi BB

    ODC-ABC-F-288

    xx PS 1:4 (yyHP)(73-120)

    xxx.xxxxE yyy yyy.yyyy

    STO ABCTC-SM-144 (3)

    FE-ABC-01-01 (01-144)

    DC-OF-SM-144D m

    FE-ABC-01-01-01 (121-144)

    DC-OF-SM-24D m

    FE-ABC-01-02(01-120)

    DC-OF-SM-144D

    m

    FE-ABC-01-02-01 (73-120)

    DC-OF-SM-48D m CAD(01 72)

    FE-ABC-02-01(01-288)

    DC-OF-SM

    -288D

    m

    DC-OF-SM

    -288D

    m

    FE-AB

    C-02-

    02

    (01-2

    40)

    CAD(01 216)

    FE-ABC-02-01-01 (241-288)

    DC-OF-SM-48D m

    FE-ABC-02-02-01 (217-240)

    DC-OF-SM-48D m

    JL

    JL

    JL

    ABC

    01/02

    ABC

    01/yy

    DC-OF-SM-288D

    m

    FE-ABC-02-

    02

    (01-240)

    Cable Slack (10m) shall be

    placed every 1000m of

    cable span and/or thelocation where the future

    demand is expected.

    STO

    ABC

    100.0

    ABC01/01

    DD-BM-HDPE-1

    150.0

    DD-BM-HDPE-1

    35.0

    HH-

    80

    HH-2

    HH-1

    HH-1

    DD-BM-HDPE-BIG-1

    150.0

    JL

    JL

    JL

    Lokasi BB

    ODC-ABC-F-288

    Lokasi AA

    ODC-ABC-F-144

    Lokasi CC

    ODC-ABC-F-288

    Lokasi DD

    ODC-ABC-F-144

    DD-BM-1

    10.0

    DD-BM-1

    10.0

    DD-ROD-1

    15.0

    DD-ROD-1

    xxxx.0

    ABC01/02

    ABC01/03

    ABC01/xx

    DD-BM-HDPE-

    BIG-1

    bbb.

    0

    aaa.

    0

    DD-BM-HDPE-

    BIG-1

    HH-1

    ABC02/03

    ABC

    02/01

    ABC

    02/xx

    ABC01/xx

    ABC

    01/xx

    ABC01/yy

    ABC02/02

    DD-ROD-1

    1.0

    DD-ROD-1

    1.0

    DD-ROD-1

    1.0

    DD-ROD-1

    xxx.0

    DD-ROD-1

    1.0

    DD-ROD-1

    1.0

    DD-ROD-1

    xxx.0

    DD-ROD-1

    1.0

    DD-ROD-1

    1.0

    DD-ROD-1

    xxx.0

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    16/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 16 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    1.4.1 SKEMA DUCT

    STO ABC

    24

    15.0

    ABC01/01ABC01/02

    ABC

    01/03

    ABC01/xx

    ABC01/yy

    6

    6

    664

    ABC

    02/02

    ABC

    02/01

    ABC

    02/xx

    100.0

    100.0

    100.0100.0100.0

    HH-2HH-80

    DD-BM-HDPE-1

    35.0

    HH-1HH-1

    DD-BM-HDPE-1

    150.0

    DD-BM-HDPE-

    BIG-1

    DD-BM-HDPE-

    BIG-1

    150.0bbb.0

    Lokasi AA

    ODC-ABC-F-144

    Lokasi BB

    ODC-ABC-F-288

    Lokasi CC

    ODC-ABC-F-288Lokasi DD

    ODC-ABC-F-144

    JL

    JL

    JL

    aaa.0

    DD-BM-HDPE-

    BIG-1

    HH-1

    Cable slack (10) shall be provided at every 1000m

    of cable length. (In case of DD-BM-HDPE, HH-1/2

    according to Page 23, 1.6.3 shall be installed.)

    Legend:

    : Assigned Duct for New Cable

    : Vacant Duct

    : Occupied Duct

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    17/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 17 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    1.4.2 SKEMA KABEL FEEDER

    Lokasi CC

    ODC-ABC-F-288xx PS 1:4 (yyHP)

    (241-288) xxx.xxxx

    E yyy yyy.yyyy

    Lokasi DD

    ODC-ABC-F-144xx PS 1:4 (yyHP)

    (217-240) xxx.xxxxE yyy yyy.yyyy

    Lokasi AA

    ODC-ABC-F-144xx PS 1:4 (yyHP)

    (121-144)

    xxx.xxxxE yyy yyy.yyyy

    Lokasi BB

    ODC-ABC-F-288xx PS 1:4 (yyHP)

    (73-120)

    xxx.xxxxE yyy yyy.yyyy

    STO ABC

    TC-SM-144 (3)

    FE-ABC-01-01 (01-144)

    DC-OF-SM-144D m

    FE-ABC-01-01-01 (121-144)

    DC-OF-SM-24D m

    FE-ABC-01-02 (01-120)

    DC-OF-SM-144D m

    FE-ABC-01-02-01 (73-120)

    DC-OF-SM-48D m

    CAD

    (01 72)

    FE-ABC-02-01 (01-288)

    DC-OF-SM-288D mDC-OF-SM-288D

    m

    FE-ABC-02-02

    (01-240)CAD

    (01 216)

    FE-ABC-02-01-01 (241-288)

    DC-OF-SM-48D m

    FE-ABC-02-02-01 (217-240)

    DC-OF-SM-48D m

    JL JL

    JL

    ABC

    01/02ABC01/yy

    DC-OF-SM-288D

    m

    FE-ABC-02-02

    (01-240)

    Cable Slack (10m) shall be

    placed every 1000m of cable

    span and/or the location where

    the future demand is expected.

    (Note: Do not show on drawing)

    ( )

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    18/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 18 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    1.4.3 PETA LOKASI KABEL FEEDER

    STO

    ABC

    ABC

    01/01

    DD-BM-HDPE-1

    150.0DD-BM-HDPE-1

    35.0

    HH-80

    HH-2

    HH-1 HH-1

    DD-BM-HDPE-

    BIG-1

    150.0

    JL

    JL

    JL

    Lokasi BB

    ODC-ABC-F-288Lokasi AA

    ODC-ABC-F-144

    Lokasi CC

    ODC-ABC-F-288

    Lokasi DD

    ODC-ABC-F-144

    DD-BM-1

    10.0

    DD-BM-1

    10.0

    DD-ROD-1

    15.0m

    ABC

    01/02ABC

    01/03

    ABC

    01/xx

    DD-BM-HDPE-

    BIG-1

    bbb.0aaa.0

    DD-BM-HDPE-

    BIG-1

    HH-1

    ABC02/02

    ABC

    02/01

    ABC02/xx

    ABC

    01/xxABC

    01/xx

    ABC

    01/yy

    ABC02/03

    DD-ROD-1xxx.0m

    DD-ROD-1100.0m

    DD-ROD-1

    100.0m

    DD-ROD-1

    100.0m

    DD-ROD-1

    100.0m

    DD-ROD-1

    100.0m

    DD-ROD-1

    100.0m

    DD-ROD-1

    100.0mDD-ROD-1

    xxx.0m

    DD-ROD-1

    xxx.0m

    1. FE-ABC-01

    2. FE=ABC-02

    Note:

    In case if plural cables

    will be installed in one

    (1) route, Cable No. tobe installed shall be

    indicated.

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    19/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 19 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    1.5 CORE ASSIGNMENT DIAGRAM1. CORE ASSIGNMENT DIAGRAM shall be prepared prior to draw the SKEMA KABELas a tool so as to

    arrange the core assignment of the feeder cable easily. (Not for submission purpose)

    2. CORE ASSIGNMENT DIAGRAM shall be prepared per each FEEDER CABLE.

    3. The higher number of core (e.g. 288 in 288-core cable) shall be assigned from the nearest ODC, and the

    youngest number shall be assigned for the furthest ODC or CAD (Spare core).

    START

    FEEDER CABLE ROUTE PLAN:

    => Draft for Skema Feeder

    1. SKEMA DUCT EXISTING shall be referred as the

    basic information for the Feeder Cable Route Plan.

    2. Plot all ODCs TO BE FED BY THE CABLE

    together with its capacity along the existing duct

    route.

    3. Where the existing duct is not available, new duct

    construction or DD-BM-HDPE shall be planned.

    4. Plot all prospected/ potential locations includingAl-Pro, MSAN, GDI etc. along the expected

    feeder cable route.

    Decision of Network

    Configuration:

    1.Ring

    2.Star/Bus

    SUM UP the required

    number of fiber cores:

    1.ODC-144: 24 cores

    2.ODC-288: 48 cores

    Decision of Feeder Cable Capacity:

    1.Required number of cores 96 96C

    2.Required number of cores 97 , 144 144

    3.Required number of cores 145 , 288 288

    4.Required number of cores 288 288 +

    another cable according to the required capacity

    Preparation of

    CORE ASSIGNMENT

    DIAGRAM

    END

    FLOW OF CORE ASSIGNMENT DIAGRAM PREPARATION

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    20/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 20 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    1.5.1 EXAMPLE OF CORE ASSIGNMENT DIAGRAM (1): STAR/BUS TOPOLOGY

    SKEMA KABEL FEEDER

    (Reference for Main Information)

    Lokasi AA

    ODC-288(241 288)

    Lokasi CC

    ODC-144(169 192)

    Lokasi DD

    ODC-144(145 168)

    Lokasi BB

    ODC-288

    (193 240)

    CAD (72)

    (01 72)

    Lokasi EE

    ODC-288

    (97 144)CAD (24)

    (73 96)

    (01 288)

    (288) (288) (288)

    (01 240) (01 192)

    (145 192)

    (01 72)

    (96)

    (48) (145 168)

    (24)

    (48)

    (97 144)(48)

    (193 240)

    (48)(241 288)

    (24)

    (169 192)

    STO ABC

    TC-OF-SM-144 (2)

    01 - 24

    25 - 48

    49 - 72

    73 - 96

    97 - 120

    121 - 144

    145 - 168

    169 - 192

    193 - 216

    217 - 240

    241 - 264

    265 - 288

    Lokasi AA

    ODC-288

    (241 288)

    Lokasi BB

    ODC-288

    (193 240)STO ABC

    Lokasi CC

    ODC-144

    (169 192)

    Lokasi DD

    ODC-144

    (145 168)

    CAD

    (73 96)

    CAD (72)

    (01 72)

    Lokasi EE

    ODC-288

    (97 144)(288)

    (96)

    (48)

    (48)

    (24) (24)

    (48) LEGEND:

    : Joint Closure

    : Fusion Splicing

    : Cable (Core)(XX)

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    21/101

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    22/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 22 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    1.6 GENERAL CONCEPT FOR FEEDER CABLE DESIGN1.6.1 ODC SPEC. (Non-HRB Type)

    ODC

    typeDesignator

    Splitter

    (1:4)Maximum HP

    Feeder

    (input Fiber core)

    Number of Cable Entry

    (Input+Output)

    48

    (pole)

    ODC-C-48 Splitter Max. 6pcs 6x32=192Star ; 12C

    Ring ; 24C

    4

    96

    (pedestal)ODC-C-96 Splitter Max. 8pcs 8*32=256

    Star ; 12C

    Ring ; 24C8

    144

    (pedestal)ODC-C-144 Splitter Max. 18pcs 18x32=576

    Star ; 24C

    Ring ; 48C12

    288

    (pedestal)ODC-C-288 Splitter Max. 36pcs 36x32=1152

    Star ; 48C

    Ring ; 96C12

    576(pedestal) ODC-C-576 Splitter Max. 72pcs 72x32=2304 Star ; 96CRing ; 192C 24

    1.6.2 FEEDER CABLE SPEC.

    Fiber Count Number of Tubes Number of Fiber/Tube Tube Diameter Outer Diameter Bending Radius

    (20 x OD)

    12C 2 6 2.1mm 12.8mm 25.6cm

    24C 4 6 2.1mm 12.8mm 25.6cm

    48C 4 12 2.5mm 13.9mm 27.8cm

    96C 8 12 2.5mm 15.6mm 31.2cm

    144C 12 12 2.5mm 19.1mm 38.2cm

    288C 24 12 2.5mm 22.1mm 44.2cm

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    23/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 23 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    1.6.3 HDPE PIPE/HANDHOLE for FEEDER CABLEIn case when the existing duct is not available and new duct (HDPE) will be installed, the following shall be taken intoconsideration:

    1) Feeder Cable with the capacity 288-core:

    HDPE BIG/SUBDUCT BIG shall be used.

    Hand-hole Type HH-1 (L=1700 x W=1250 x D=1300) shall be used for all locations.

    2) Feeder Cable with the capacity 144-core

    HDPE 33/40/SUBDUCT shall be used. Hand-hole Type HH-1 (L=1700 x W=1250 x D=1300) shall be used for all locations.

    3) Feeder Cable with the capacity 96-core or less

    HDPE 33/40/SUBDUCT shall be used.

    Hand-hole Type HH-2 (L=1200 x W=600 x D=1300) shall be used for all locations

    1.6.4 HANDHOLE for ODC

    At ODC location, HANDHOLE shall be installed:

    1) Type HH-1 (L=1700 x W=1250 x D=1300):

    Where the Jointing Closure from the Feeder Cable with 288/144-core.is installed including the locationwhere slack is located for future jointing.

    2) Type HH-2 (L=1200 x W=600 x D=1300):

    Where Handhole shall be located on the carriage way.3) Type HH-80 (L=800 x W=800 x D=800):

    Where Handhole will be located on the Green Area (Taman) in the housing area (Perumahan) and whereno jointing closure will be located.

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    24/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 24 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    1.6.5 PASS THROUGH CLOSURE for FEEDER CABLE

    Through Cable

    Type

    Model No. (3M)

    48core 2179CS Type 1 : 24core tray (1)

    Size ; 447mm x 175mm x 107mm

    96core, 144core 2179C Type 2 : 24core tray (1)

    Type 3 : 24core tray (2)

    Size ; 557mm x 215mm x 119mm

    288core 2178LS Type 4 : 24core tray (2)

    Type 5 : 24core tray (4)

    Size ; 557mm x 216mm x 203mm

    Option: 24core tray , Re-entry kit

    Consultation shall be necessary in case when the other optional items are required.

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    25/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 25 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    2. DISTRIBUTION CABLE DESIGNMaximum Usage of Distribution Cable shall be 80% of the cable capacity:Maximum No. of ODP: No. of Spare Core (CADANGAN)

    1) 8-Core Cable: 6 (Only for Branch Section) 2 CORE CAD.

    2) 12-Core Cable: 10 2 CORE CAD.

    3) 24-Core Cable: 20 4 CORE CAD.

    2.1 GOOGLE MAP1) ODC (Name/Capacity)

    2) Distribution Cable Route

    3) Location of ODP

    2.2 SKEMA KABEL DISTRIBUSI

    Purpose: Information required for the Distribution Cable Work1) ODC

    ODC Capacity

    ODC No. FA, FB, .......

    Code STO

    Code ODC

    ODC-XXX-FA-288

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    26/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 26 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    2) DISTRIBUTION CABLE

    DSXXX-FE 01-01-01/01-01-01 (01-24)

    Core No. In Cable

    Segment No.

    Label Feeder (Feeder No., Segment No.)Code STO

    DC-OF-SM-24SC-xxM

    Cable Length in meter

    Designation for Easy to Split Cable

    No. Of Cores

    Type of Cable

    Duct Cable: DC-OF-SMAerial Cable: AC-OF-SM

    Code Distribution CableDistribution No.

    Branch-Segment No.

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    27/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 27 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    3) ODP

    FA/D01/xx/yy

    (xx)

    No. No.

    Number of Splitter 1:8

    1: ODC-8

    2: ODC-16

    ODP No.

    Note: 1. Continuous number starting from D01:

    example: 10 ODP on D01, ODP on D02 shall be

    started from No.11.

    2. ODP No. shall be given from the far most ODPfrom ODC location.Distribution Cable No.

    ODC No.

    Core No. to be terminated at ODP

    e.g. from 01 to 24

    The largest No. of care shall be allocated to the nearest

    ODP from ODC.

    House No. in front ofODP Location

    Coordinates Lokasi ODP

    Note: Grounding shall be placed at the last ODP for each distribution cable.

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    28/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 28 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    2.3 SAMPLE DESIGN OF DISTRIBUTION CABLE NETWORK

    1) SKEMA KABEL DISTRIBUSI

    2) PETA LOKASI KABEL DISTRIBUSI

    2.3.1 CASE-1: UNDERGROUND/DUCT CABLE

    ODC-F-144

    xx PS 1:4 (yyHP)

    DSABC-FE-01-01/01-01 (01-12) DSABC-FE-01-01/01-02 (01-10) DSABC-FE-01-01/01-03 (01-09) DSABC-FE-01-01/01-xx (01-05)

    F/D01/07/02

    (11-12)N ...

    E .......

    N ...

    E .......

    F/D01/06/01

    (10)

    N ...

    E .......

    F/D01/05/01(09)

    ODP-PW-BRN ...

    E .......

    F/D01/01/02

    (03-04)

    N ...

    E .......

    CAD

    (01-02)

    DC-OF-SM-12-SC ..m DC-OF-SM-12-SC ..m DC-OF-SM-12-SC ..m DC-OF-SM-12-SC ..m

    3 4 9 10 16 17 31

    F/D01/04/01

    (08)

    DSABC-FE-01-01/01-03-01 (08)

    DC-OF-SM-8-SC ..m

    N ...

    E .......

    JL. ..

    HH-2

    ODC-F-144

    xx PS 1:4

    (yyHP)

    DD-BM-HDPE-1 ..mDD-BM-HDPE-1 ..m

    DD-BM-HDPE-1 ..m

    DD-BM-HDPE-1 ..m

    DD-BM-1 ..m

    DD-BM-1 ..m

    DD-BM-1 ..m

    DD-BM-HDPE-1 ..m

    DD-BM-HDPE-1 ..m

    DD-BM-HDPE-1 ..m

    DD-BM-1 ..m

    DD-BM-HDPE-1 ..m

    DD-BM-1 ..m

    1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 29 30

    31

    32

    DD-BM-HDPE-1 ..m

    F/D01/07/02 F/D01/06/01F/D01/05/01

    ODP-PW-BR F/D01/01/02

    F/D01/04/01

    JL. ..

    Note:

    At the BRANCHING, the core

    assignment and the ODP No. shall be

    in accordance with the rule below.

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    29/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 29 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    STO ABC NAMA LOKASI Cluster AA (ODC-F-144)DISTRIBUTION

    CABLE No.D-01 CAPACITY 12-CORE

    FEEDER SEGMENT DISTRIBUTION SEGMENT

    OTB

    Port No.

    ODC

    PORT No.

    SPLITTER 1:4 ODC TRAY CORE

    No.No. Port No. PORT No.

    49 1 1

    1

    1

    1 1

    2 2 2

    3 3 3

    4 4 4

    50 2 2

    1 5 5

    2 6 6

    3 7 7

    4 8 8

    51 3 3

    1 9 9

    2 10 10

    3 11 11

    4 12 12

    7 6 5 4 3 2

    3) CORE ASSIGNMENT DIAGRAM (For CASE-1)

    1

    CAD

    8-C

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    30/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 30 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    2.3.2 CASE-2: AERIAL CABLE1) SKEMA KABEL DISTRIBUSI

    2) PETA LOKASI KABEL DISTRIBUSI

    ODC-F-144

    xx PS 1:4 (yyHP)

    DSABC-FE-01-01/01-01 (01-12) DSABC-FE-01-01/01-02 (01-11) DSABC-FE-01-01/01-03 (01-10) DSABC-FE-01-01/01-xx (01-05)

    F/D01/08/01

    (12)N ...

    E .......

    N ...

    E .......

    F/D01/07/01

    (11)

    N ...

    E .......

    F/D01/06/01

    (10)

    ODP-PW-BRN ...E .......

    F/D01/01/01

    (05)

    N ...E .......

    CAD

    (01-04)

    AC-OF-SM-12-SC ..m AC-OF-SM-12-SC ..m AC-OF-SM-12-SC ..m AC-OF-SM-12-SC ..m

    3 4 9 10 16 17 31

    F/D01/05/01

    (09)

    DSABC-FE-01-01/01-03-01 (09)

    AC-OF-SM-8-SC ..m

    N ...

    E .......

    JL. ..

    HH-2

    ODC-F-144

    xx PS 1:4

    (yyHP)

    1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 29 30

    31

    32

    F/D01/08/02 F/D01/07/01F/D01/06/01

    ODP-PW-BR F/D01/01/01

    F/D01/05/01

    JL. ..

    BC-PP 3m 30m 45m 45m 45m

    45m

    25m.m

    LEGEND

    : New Pole

    : Existing Pole Branching ODP(1 x 1:8 Splitter)

    ODP Aerial(1 x 1:8 Splitter)

    30m

    Note:

    At the BRANCHING, the core

    assignment and the ODP No. shall be

    in accordance with the rule below.

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    31/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 31 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    3) CORE ASSIGNMENT DIAGRAM (For CASE-2)

    STO ABCABCABCABC NAMA LOKASI Cluster AA (ODC-F-144) DISTRIBUTION

    CABLE No.D-01 CAPACITY 12-CORE

    FEEDER SEGMENT DISTRIBUTION SEGMENT

    OTB

    Port No.

    ODC

    PORT No.

    SPLITTER 1:4 ODC TRAY

    CORE No.No. Port No. PORT No.

    49494949 1111 1111

    1

    1111

    1 1

    2 2 2

    3 3 3

    4 4 4

    50505050 2222 2222

    1 5 5

    2 6 6

    3 7 7

    4 8 8

    51515151 3333 3333

    1 9 9

    2 10 10

    3 11 11

    4 12 12

    ODP No. 15 34 2678

    CAD

    12-C 12-C

    8-C

    HANDBOOK f

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    32/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 32 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    Main Cable

    (SCPT-8/12/24-core)

    ODP Pedestal/Wall

    Capacity: 8 or 16

    ODP Pedestal/WallCapacity: 8 or 16

    Branching Cable(SCPT-8-core)

    Branching ODP(1 x 1:8 Splitter)

    Designator:

    ODP-PL-BR

    2.4 BRANCHING ODP

    1) Underground Cable

    (Pedestal/Wall Mount)

    Branching ODP shall be used in case when the several ODP locations are not suitable to be fed by the main cable but

    independent cable installation is also not efficient due to the limited number of ODP (Less than 8 ODP).

    Branching ODP:

    1)Branching ODP is applicable for both underground as well as aerial distribution cable design.

    2)Type of ODP is Cabinet type to be mounted on: WALL, POLE and PEDESTAL.

    3)The cable to be branched from the main cable shall be of 8-Core.

    4)The number of ODP on branched cable shall be less than 8.5)The branching ODP is able to accommodate only one (1) unit of 1:8 Splitter.

    2) Aerial Cable

    (Pole Mount)

    Main Cable

    (SSW-8/12/24-core)

    ODP Aerial

    Capacity: 8

    ODP AerialCapacity: 8Branching Cable

    (SCPT-8-core)

    Branching ODP(1 x 1:8 Splitter)

    Designator:

    ODP-P/W-BR

    HANDBOOK f

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    33/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 33 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    2.5 DUCT USAGE FOR DISTRIBUTION NETWORK &DROP-CORE INSTALLATION (UNDERGROUND)

    ODC ODP/ ODP ODP

    1)DD-BM-HDPE

    2)BC-TR-1.5 + DD-HDPE

    ODP (HH-PIT-60) HH-PIT-40/

    HH-PIT-40 HH-PIT-40

    1) BC-TR-0.6 + DC-SD-1 BigHH-PIT-60

    HH-PIT-40

    HH-PIT-40

    HH-PIT-40 - Premises

    1) BC-TR-0.4 + PP-OF-OUT(PVC )

    HANDBOOK for

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    34/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 34 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    3. GENERAL CONCEPT FOR DISTRIBUTION CABLE DESIGN

    1) Bila ditemukan jalan buntu pada perumahan dengan jalak Drop core

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    35/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 35 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    2) Bila ditemukan jalan buntu pada perumahan dengan jalak Droop core >100 meter makadiperbolehkan menggunakan ODP Branch dari kabel distribusi untuk kabel yang akan menuju ke

    ODP dengan jumlah branch sesuai denga HP, Gambar Terlampir :2) When you find a blind alley which need drop cable more than 100 m, it is allowed to use the ODP Branch from the

    main distribution cable according to the quantity of HP. Please see the illustration below.

    HANDBOOK for

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    36/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 36 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    3) Bila ditemukan jalan tidak buntu pada perumahan maka penarikan kabel distribusi dapat dilakukansecara mengelilingi perumahan yang letak ODP di sesuaikan dengan jumlah HP, Gambar Terlampir :3) When it is not a blind alley, span of the cable should pass around the complex and placement of ODP should be

    adjusted according to the HP. Please see the illustration below.

    HANDBOOK for

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    37/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 37 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    3.2 AERIAL SECTION1) Sample Design based on Duct Cable Design Standard

    => (Some consideration due to particularity of the aerial cable shall be required.)

    6.5m 45m

    6.5m

    30m

    45m 45m

    40m

    45m45m

    45m11m

    45m

    45m

    25m

    25m

    6.5m

    35m45m

    45m45m

    Road width

    more than 6m

    Road width

    less than 6mAC-OF-SM-12-SC

    AC-OF-SM-8-SC

    AC-OF-SM-8-SC

    AC-OF-SM-12-SC

    ODP-BR

    ODP-BR

    Note: Location where specialconsideration is required due

    to a particularity of the aerialcable installation

    : ODC

    : ODP

    1) ODP-SSW-8

    2) ODP-BR

    : HH-2/HH-80

    : New Pole 7m/9m

    LEGEND

    C-CLAMP x 2

    Detail for Riser Part

    SSW CABLE

    Cable part shall be

    protected with Spiral

    for outdoor use (Black

    color)

    Detail forRiser Part

    Note: Prior to plotting ODP on the map, ODP Boundary (Max. 8HP) shall be designated so that the numberof ODP and its location can be planned efficiently.

    HANDBOOK for

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    38/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 38 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    2) Sample Design based on Particularity for Aerial Cable

    : Additional Pole for

    Drop Core

    LEGEND for Additional Item

    : Drop Core Run

    6.5m

    45m

    6.5m

    40m

    45m

    45m

    40m

    45m

    45m

    45m11m

    45m

    45m

    25m

    25m

    6.5m

    35m

    45m

    45m

    45m

    Road widthmore than 6m

    Road width

    less than 6m

    30m

    35m

    10m

    15m

    25m

    30m

    30m

    40m

    35m

    25m

    35m

    Detail "Drop-A"

    Detail "Drop-B" Detail "Drop-C"

    Note: Location where special

    consideration is taken due to

    a particularity of the aerial

    cable installation

    Some particular consideration required for

    Aerial Cable Design

    1. Additional pole(s) may be required for the

    drop cable installation. (Actual installationof additional poles shall be decided in

    accordance with contract with the

    developper/owner)

    2. Road width less than 6m can be crossed by

    the drop cable as far as the road traffic will

    not be disturbed otherwise new pole shall

    be installed.

    3. Location of ODP shall be decided so that:1) Drop cable can be installed along SSW

    cable.

    2) Drop cable can be installed indipendently

    for one (1) span (2 spans at maximum)

    HANDBOOK for

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    39/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 39 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    C-CLAMP x 2

    SSW CABLE

    Cable part shallbe protected with

    Spiral for outdoor

    use (Black color)

    3) Details of SSW Installation

    A. Details of Riser Part B. ODP-SSW Location

    10cm

    ODP-SSW-8

    B-1. With C-CLAMP

    C. Cable Allignment

    As far as it is practical, thecable shall be installed so

    that the suspension wire is

    always above the cable part.

    Suspension Wire

    Cable Part

    At the cable laying, turns inthe cable shall be released

    by turning the cable winding

    while making the 8-figure.

    50mm

    Bend

    150mm remove sheath

    D. C-LAMP E. Line Guard Installation

    30cm

    Line Guard

    L= 51cm

    ODP-SSW-8

    B-2. With LINE GUARD

    SUSPENSION CLAMP

    25cm

    < 120

    LINE GUARD shall be installed where:1. One (1) in every three (3) poles in the

    straight line.

    2. At the pole beside the ODP-SSW is

    installed except the location where C-CLAMP is installed.

    Caution:LINE GUARD shall be fixed and the Suspension

    Wire at C-CLAMP shall be bent ONLY after all

    ODP-SSW installation have been completed

    and the cable allignment has been confirmed

    so that no turn is contained in the cable span.

    : SSW Cable (Japan)

    LEGEND

    : C-Clamp (Japan)

    HANDBOOK for

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    40/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

    Page 40 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    Drop Cable

    (Aerial)

    HC-OF-SM-2D

    4) Details of Drop-Core Solution

    Detail "Drop-A"

    Messenger wire from drop cable to pole or1.2mm galvanized steel wire with sheath coating

    Detail "Drop-B"

    Detail "Drop-C"

    : S-Clamp (Japan)

    LEGEND

    : D-Clamp (Japan)

    : BW-Clamp (Local)

    FUSE-CONNECT

    ISC-UPC-FD

    ROSETTE

    RS-IN-SC-1P/

    TC-MK-SC-1P

    Details of "Home Connect"

    ODP-SSW-8

    ODP-PL/PW-

    8/16Drop Cable

    (Underground)

    GC-OF-SM-2D

    Wire Grip 3/8"

    with double nut

    HANDBOOK for

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    41/101

    FTTH OSP (PT TELKOM INDONESIA)

    Page 41 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    4. CABLE RACK/OTB RACK IN STO BUILDING

    Note:

    1. The cable routing in the STO building shall be

    measured so as to estimate the cable length

    from the duct entrance at the Cable Chamberuntil the OTB.

    2. In case when the new rack shall be provided, the

    rack to be installed shall be of same type and

    the same color with the existing one.

    3. In the decision of the location of 19 rack

    installation, well coordination with DBB, Telkom

    Area and/or WASPANG is required.

    4. When the location of new 19 Rack installation

    is fixed, the designated location on the floor

    shall be clearly marked with an adhesive tape

    and a permanent markeras:

    FTTH OSP

    JF DJAFa

    5. The maximum number of unit of TC-OF-SM-144

    to be accommodated in the 19 Rack with

    Height of 2.20m shall be FIVE (5).

    CABLE

    CHAMBER

    MDF

    ROOM OTB ROOM/

    TRANSMISSION

    ROOM

    19R

    ACKH=2200

    Max.5xTC-OF-SM-144

    FEEDER

    CABLE

    STO BUILDING

    CABLE RACK

    HANDBOOK for

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    42/101

    FTTH OSP (PT TELKOM INDONESIA)

    Page 42 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    5. HIGH-RISE BUILDING (HRB) DESIGN

    No. Designator ApplicationNo. of Splitter

    (Max.)

    Number of PortHome Pass

    Accommodated (80%)In Out Total

    1. ODC for HRB/MDU (Approx.)

    1.1 ODC-HRB-180 (*) Cabinet/ Wall 1:4 x 36 36 144 180 900

    1.2 ODC-HRB-240 (*) Cabinet 1:4 x 48 48 192 240 1200

    1.3 ODC-HRB-420 (*) Cabinet 1:4 x 84 84 336 420 2200

    1.4 ODC-HRB-RACK-120 (**) 19" Rack Mount 1:4 x 24 24 96 120 600

    1.5 ODC-HRB-RACK-240 (**) 19" Rack Mount 1:4 x 48 48 192 240 1200

    1.6 ODC-HRB-RACK-480 (**) 19" Rack Mount 1:4 x 96 96 384 480 2500

    2. ODP for HRB/MDU (Installed) (Max.)

    2.1 ODP-HRB-16 (*) Wall Mount1:8 x 1 - 8 8

    161:8 x 2 - 16 16

    2.2 ODP-HRB-32 (*) Wall Mount1:8 x 3 - 24 24

    321:8 x 4 - 32 32

    3. 2-C Low Friction Indoor Cable

    3.1 IC-OF-SM-1D

    Distribution/ Drop-core

    1-Core (G657A) Low Friction Indoor Cable for DISTRIBUTION-CABLE

    3.2 IC-OF-SM-2D 2-Core (G657A) Low Friction Indoor Cable for DROP-CABLE1-Core connected with Fuse-Connect (ISC-UPC-FD), 1-Core for spare

    4. ROSETTE SC Adapter

    4.1 RS-IN-SC-1P 1Indoor Rosette4.2 RS-IN-SC-2P 2 To be discussed when necessary (***)

    4.3 RS-IN-SC-4P 4 To be discussed when necessary (***)

    4.4 TC-MK-SC-1P 1

    Indoor Rosette (Buried inwall)

    4.5 TC-MK-SC-2P 2 To be discussed when necessary (***)

    4.6 TC-MK-SC-4P 4 To be discussed when necessary (***)

    5.1 MATERIAL FOR HRB SOLUTION

    Note (*): New Item (Specifications have been accepted by TELKOM)(**): New Item (Specifications shall be subject to concurrence by TELKOM)

    (***): To be discussed with DBB TELKOM when 2P or 4P Rosette is required by the Developer

    HANDBOOK for

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    43/101

    FTTH OSP (PT TELKOM INDONESIA)

    Page 43 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    1-Core Low Friction Indoor Cable for

    1x 1:8 Splitter with Field Installable SC Connector

    (Fuse-connect) x 1pc at both ends

    ODC-HRB-

    1) 180

    2) 240

    3) 420

    ODC-HRB-RACK-

    1) 120

    2) 2403) 480

    Feeder Cable:

    1) For ODC-HRB-180: 24/48C

    2) For ODC-HRB-240: 48C

    3) For ODC-HRB-480: 96C

    ODP:

    1) ODP-HRB-16: Up to 16 HP (1or 2 x 1:8 Splitter)

    Size: H=330 x W=260 x D=130

    2) ODP-HRB-32: Up to 32 HP (3 or 4 x 1:8 Splitter)

    Size: H=412 x W=312 x D=140

    ODP-

    HRB

    Cable Tray/Shaft/Ladder

    Rosette: TC-MK-SC-xP

    (1-Port/2-Port/4-Port)

    2-Core Low Friction Indoor Cable

    with Field Installable SC Connector

    (Fuse-connect) x 1pc at both ends

    ODP-

    HRB

    4) For ODC-HRB-RACK-120: 24C

    5) For ODC-HRB-RACK-240: 48C

    6) For ODC-HRB-RACK-480: 96C

    5.2 DESIGN CONCEPT FOR HRB SOLUTIONDESIGN CONCEPT FOR HRB

    1. ODC shall be selected among all types

    according to the site situation as well as

    number of Home Pass of the target

    building.2. ODP shall be selected among three (3)

    types according to the number of Home

    Pass and the Floor Layout.

    3. 2-Core Low Friction Indoor Cable shall

    be used between ODC and ODP.

    4. One (1) Low Friction Indoor Cable shall

    be connected ODC Port with one (1) 1:8

    Splitter of ODP i.e.:1) ODP-HRB-16: One (1) or two (2) Low

    Friction Indoor Cable:

    a. 1 x 1:8 Splitter: 1 Low Friction Cable

    b. 2 x 1:8 Splitter: 2 Low Friction Cables

    2) ODP-HRB-32: Three (3) or four (4) Low

    Friction Indoor Cables:

    a. 3 x 1:8 Splitter: 3 Low Friction Cables

    b. 4 x 1:8 Splitter: 4 Low Friction Cables

    HANDBOOK for

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    44/101

    FTTH OSP (PT TELKOM INDONESIA)

    Page 44 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    5.3 Type of ODC for High-Rise-Building1) CABINET TYPE 2) RACK MOUNT TYPE

    (To be mounted in the Closed Rack H=1.20m)

    H= 770

    W=555

    D=310

    ODC-HRB-180

    Application: Wall/Floor

    D=360

    H= 1450

    W=750

    ODC-HRB-240/420Application: Floor

    W=428

    H= 275

    D=302.3

    ODC-HRB-RACK-120

    Application: 19" Rack

    W=428

    D=302.3H= 445

    ODC-HRB-RACK-240

    Application: 19" Rack

    W=428

    D=302.3

    H= 890

    ODC-HRB-RACK-480

    Application: 19" Rack

    HANDBOOK for

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    45/101

    FTTH OSP (PT TELKOM INDONESIA)

    Page 45 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    5.4 Example of Cable Tray/Trunking

    1) HORIZONTAL RUN

    (a) On the Cable Tray

    Cable Tray

    Cable Trunking

    (b) Direct Attachment to the Building Wall

    2) VERTICAL RUN

    ODP-

    HRB

    Elbow (Flat Angle)

    T-Joint

    Cable Trunking

    HANDBOOK for

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    46/101

    FTTH OSP (PT TELKOM INDONESIA)

    Page 46 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    5.5 SAMPLE DESIGN: SKEMA DISTRIBUSI

    ODC ABC BUILDING

    F.../STO/HRB-xxx

    xx PS 1:4 (xxx HP)S 6

    E 106 ...

    x IC-OF-SM-1D __mx IC-LF-OF-SM-1D __m

    x IC-OF-SM-1D __m

    2 IC-OF-SM-1D__m

    x IC-LF-OF-SM-1D __m

    1 IC-LF-OF-SM-1D __m 2 IC-OF-SM-1D __m

    x IC-OF-SM-1D __m

    x IC-OF-SM-1D __m

    F/P01-02/1/2

    ODP-HRB-16

    F/P03/2/1

    ODP-HRB-16

    (Note: Not "8")

    ODC No.

    Code STO

    "HRB"-"Capacity"

    180

    240

    420

    No. of Splitter No. of Home Pass

    No. of Splitter 1:8ODP No.

    ODC Port No.

    Each No. to be given for Each 1-Core

    Indoor CableODC No.

    Specify "Tower" and/or

    "Shaft" according to the

    Building Layout.

    F/P04-05/3/2

    ODP-HRB-16

    2: No. of Indoor Cable to be installed and

    terminated to ODP

    __m: Cable Length from ODC to ODP

    Tower A/

    Shaft No.1

    Floor-xx

    Floor-yy

    Floor-zz

    Descriptions for ODC

    ODC XXX (Name of Building)

    2. F... /STO /HRB-(RACK)-xxx

    3. xx PS 1:4 (xxx HP)

    4. Coordinates

    1. F/ P-03/ 2/ 1

    Descriptions for ODP

    2. ODP-HRB-xx

    Type of ODP: ODP-HRB-16, 32 (See Note above.)

    Note:

    Type of ODP-HRB is 2:

    1. ODP-HRB-16: No. of 1:8

    Splitter= 1 or 2

    2. ODP-HRB-32: No. of 1:8

    Splitter= 3 or 4

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    47/101

    FTTH OSP (PT TELKOM INDONESIA)

    Page 47 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    5.6 SAMPLE DESIGN: PETA LOKASI DISTRIBUSI

    1) PETA LOKASI KABEL DISTRIBUSI (Vertical View)

    Tower A

    F/P03/2/1

    ODP-HRB-16Note: Not "8"

    F/P04-05/3/2

    ODP-HRB-16

    ODC ABC BUILDING

    F.../STO/HRB-xxx

    xx PS 1:4 (xxx HP)

    F/P01-02/1/2

    ODP-HRB-16

    Cable Shaft No.1 Cable Shaft No.2

    Cable Tray/Trunking to be installed

    e.g. Cable Tray W=100mm x 35m

    1

    LEGEND

    : ODC-HRB

    : ODP-HRB

    : Cable Tray/Trunking

    (New)

    2

    : Rosette (1-Port)

    : Rosette (2-Port)

    : Cable Tray/Trunking

    (Existing)

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    48/101

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    49/101

    FTTH OSP (PT TELKOM INDONESIA)

    Page 49 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    Table-1: List of Port Management

    ODC Port

    No.

    Distribution

    Cable No.

    ODPUnit No.

    Drop Cable

    Length (m)No./Floor Splitter No. Port

    1 D01

    8

    1

    1 1 30.0

    2 2 18.0

    3 3 10.0

    4 25 55.0

    5 26 50.0

    6 27 45.0

    7 28 40.0

    8 29 35.0

    2 D02 2

    1 11

    12

    30

    31

    32

    33

    34

    35

    6

    7

    8

    3) LIST OF PORT MANAGEMENT & DROP-CORE LENGTH

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    50/101

    FTTH OSP (PT TELKOM INDONESIA)

    Page 50 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    51/101

    FTTH OSP (PT TELKOM INDONESIA)

    Page 51 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    6.1 PONDASI ODC-C-144 Splitter

    Keterangan:

    Pondasi dan lantai kerja berlapis keramik.

    1. Pondasi: Keramik 20 x 20, warna biru

    2. Lantai kerja: Keramik 20 x 20 Non-slip, warna biru

    310mm

    103

    5mm

    555mm

    463

    170

    500

    600

    660

    360150 150

    ODC Foundation: A-A(Not to scale/ Unit: mm)

    98.5 98.5

    75 85mm

    Drill:14mm/ d= 75 85mm(Expansion Bolt: M8 x 150)

    1100

    463

    G.L

    52.5 52.5555

    ODC Foundation: B-B

    (Not to scale/ Unit: mm)

    440

    150 150140

    115 115170

    75 85mm

    Drill:14mm/ d= 75 85mm

    (Expansion Bolt: M8 x 150)

    G.L

    31065 65

    ODC Foundation: Top View(Not to scale/ Unit: mm)

    150

    150

    140

    440

    150 150360

    660

    440

    135

    135

    1

    70

    660

    98.598.5

    463

    Drill:14mm/ d= 75 85mm

    A A

    B

    B

    (Expansion Bolt: M8 x 150)

    ODC Foundation

    Conduit Connection

    (Not to scale/ Unit)

    R > 500mm

    W=600

    (HH-2)

    Handhole

    Type:HH2

    5 x HDPE 33/40

    (B-B Side)

    Approx.30cm or less

    Approx. 30cm

    G.L.

    - 200

    0

    - 1500

    - 1000

    HandholeType:HH-80

    W=800(HH-80)

    - 600

    Special Attention:

    Cable Slack shall be placed only in

    HANDHOLE/HH-PIT and never belocated in the ODC Foundation.

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    52/101

    FTTH OSP (PT TELKOM INDONESIA)

    Page 52 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    6.2 PONDASI ODC-C-288 Splitter

    150

    150

    140440

    165 165520

    850

    440

    120

    120

    200

    850

    119 119612

    Drill:18mm/ d= 60 80mm

    ODC Foundation: Top View(Not to scale/ Unit: mm)

    A A

    B

    B

    (Expansion Bolt: M12 x 150)

    320mm

    1450m

    m

    750mm

    ODC Mount and

    Location of Anchor

    Bolt

    612

    200

    ODC Foundation: A-A

    (Not to scale/ Unit: mm)

    G.L

    500

    600

    850

    520165 165

    119 119

    60 80mm

    Drill:18mm/ d= 60 80mm

    (Expansion Bolt: M12 x 150)

    1100

    612

    50 50750

    Keterangan:

    Pondasi dan lantai kerja berlapis keramik.

    1. Pondasi: Keramik 20 x 20, warna biru2. Lantai kerja: Keramik 20 x 20 Non-slip, warna biruODC Foundation: B-B

    (Not to scale/ Unit: mm)

    440

    150 150

    120 120200

    60 80mm

    Drill:18mm/ d= 60 80mm

    (Expansion Bolt: M12 x 150)G.L

    60 60320

    140

    Conduit Connection

    (Not to scale/ Unit)

    R > 500mm

    W=600(HH-2)

    HandholeType:HH2

    5 x HDPE 33/40

    (B-B Side)

    Approx.30cm or less

    Approx. 30cm

    G.L.

    - 200

    0

    - 1500

    - 1000

    HandholeType:HH-80

    W=800(HH-80)

    - 600

    ODC Foundation

    Special Attention:Cable Slack shall be placed only in

    HANDHOLE/HH-PIT and never be

    located in the ODC Foundation.

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    53/101

    FTTH OSP (PT TELKOM INDONESIA)

    Page 53 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    500

    100 300 100

    TELKOM

    500

    100

    100

    300

    300

    PVC 4"

    Sub-duct BIG

    500

    700

    200

    150

    150

    100

    100

    Distance in accordance with

    the site situation.

    Jaak sesuai kondisi lapangan.

    150 150400

    700

    900

    100 100

    Sub-duct BIG

    PVC 4"

    PVC 4" for

    Drop Cable

    L=300

    PVC 4" for

    Distribution Cable

    L=300

    450

    150

    900

    600150 150

    150

    600

    150

    900

    700

    150

    500

    200150 150

    100 100

    150

    100

    80

    220

    H

    600-H

    600

    500

    100 100 300

    150 150400

    700

    LARGE RADIUS ELBOW

    PVC 4"

    (WAVIN D-LL 4" or Equivalent)

    PVC4"

    L=

    650

    Distance in accordance with

    the site situation.Jaak sesuai kondisi lapangan.

    6.3 PONDASI ODP PEDESTAL & HH-PIT-60

    Cable Installation Method between HH-PIT-60 and ODP

    Distribution Cable Installation

    shall cautiously be carried out

    so that the Bending Radius of

    20cm shall be secured.

    Note H: Height above ground

    shall be minimum 10cm. Actualheight shall be in accordance

    with the site condition.

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    54/101

    FTTH OSP (PT TELKOM INDONESIA)

    Page 54 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    1300

    250

    150

    900

    250 1000

    1250

    288-C cable

    R= 44.2mm

    +- 150cm

    557mm

    450625 625

    1700

    1300

    250

    150

    +-90cm

    450625 625

    PASS-THROUGH CLOSURE ARRANGEMENT IN HH-1

    (288-C Loose Tube Cable / 3M Type 2178LS)

    BESI 70 x 50 x 3

    150 1501250

    1550

    100 1001350

    200 200950

    1550

    Hole 20mm

    10mm x 125mm

    POT B - B

    12mm x 125mm

    PVC 4" x 4

    L= 300

    1

    5

    0

    1

    5

    0

    1

    5

    01

    5

    0

    10mm x

    125mm

    BETON: 225kg/cm

    150 1501700

    2000

    200

    150

    1300

    1650

    600 600100 100

    200 200 200200 200 200

    10mm x 125mm

    10mm x 125mm

    POT A - A

    600

    200 200 200

    12mm x 125mm

    150

    150

    L=300

    TE

    L

    K

    OM

    TE

    L

    K

    OM

    TE

    LK

    O

    M

    150

    150

    150

    950

    1550

    A A

    B

    B

    100200200200 200 200200

    2000

    200 200100

    1350

    3 x 600 = 1800

    150

    TELKOM

    200

    TELKO

    M

    TELKO

    M

    6.4 HH-1: Dimensi Dalam (P=1700 x L=1250 x T=1300)

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    55/101

    FTTH OSP (PT TELKOM INDONESIA)

    Page 55 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    BESI 70 x 50 x 3

    150 150600

    900

    100 100700

    150150

    400

    900

    Hole

    20mm

    10mm x 125mm

    POT B - B

    PVC 4" x 4

    L= 300

    150

    150150

    150

    T

    E

    LK

    O

    M

    100 225 225 100200 225225 200

    1500

    150

    150

    150

    300

    900A A

    B

    B

    T

    E

    L

    K

    O

    M

    2 x 650 = 1300

    700

    150

    PVC 4" x 4

    L= 300

    150 1501200

    1500

    200

    150

    1

    300

    1650

    650 650100 100

    225 200 225225 200 225

    150

    10mm x 125mm

    10mm x 125mm

    POT A - A

    150

    L=300

    6.5 HH-2: Dimensi Dalam (P=1200 x L=600 x T=1300)

    BETON: 225kg/cm

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    56/101

    FTTH OSP (PT TELKOM INDONESIA)

    Page 56 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    6.6 HH-80: Dimensi Dalam (P=800 x L=800 x T=800)

    150150 800

    1100

    150

    10mm x 125mm

    10mm x 125mm

    200

    150

    800

    1150

    100

    200

    450

    1100

    125

    150

    L=300

    450 100

    125 200125 125

    POT A - A

    Hole 20mm

    150

    150150 PVC 4" x 4

    L= 300

    BESI 70 x 50 x 3

    10mm x 125mm

    150 150800

    1100

    200

    150

    800

    11

    50

    1100

    100 100900

    150 150600

    150

    POT B - B

    B

    T

    E

    LK

    OM

    1100

    150

    100

    1100A A

    B

    1100

    PVC 4" x 4

    L= 300

    900

    T

    E

    LK

    OM

    150

    100

    60

    0

    100

    125

    100

    200

    450

    1100

    450

    125 125 200 125

    BETON: 225kg/cm

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    57/101

    ( )

    Page 57 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    G.L.

    Approx.2.20m

    10cm

    30cm10c

    m30cm

    Approx.

    10cm

    Clampsshallbeattached

    Approx.@

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    58/101

    ( )

    Page 58 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    Flex. Pipe

    OD=25mmSteel flexible inside

    HH PIT-60

    150

    Flex-pipe

    R300

    Approx.

    200

    Appro

    x. 100

    Approx. 100

    Approx. 100

    Flex-pipe R300

    Flex-pipe

    R300

    Flex-pipe

    R300

    Flex-pipeR300

    PVC Simple

    Socket for OD

    25mm Pipe

    PVC/High-Impact

    Conduit OD 25mm

    PVC/High-Impact

    Conduit OD 25mm

    Pipes shall be buried in the wall.

    Pipe space shall be filled with

    concrete after ODP installation.

    150

    Approx.

    200

    100

    50

    Approx.

    100

    HH PIT-60

    Note:

    In case when pipes shall be buried in the building wall due to the

    requirement by the developer, the following points shall be taken into

    account for the installation.

    1. HH-PIT-60 shall be installed in front of ODP location.

    2. Flexible Pipe with steel (OD 25mm) shall be used at the bending part of

    conduit.

    3. Bending Radius of Flexible Pipe shall be more than 300mm.4. PVC/High-Impact Pipe (OD 25mm) shall be used at the straight part of

    conduit.

    5. PVC Simple Socket for OD 25mm Pipe shall be used at all jointing part.

    6. Pipe space of wall shall be filled with concrete after installation of ODP.

    (ODP termination work shall be done prior to the pipe fixing and concrete

    work.)

    7. The wall shall be restored to the original condition and painted with the

    same color with the original wall.

    MOM/BA shall be made (to be signed by the PIC of the developer) for theconfirmation of the requirement.

    2 x PVC 50

    (L=200)

    Pipes shall be buried in the wall.

    Pipe space shall be filled withconcrete after ODP installation.

    Drop Cable

    6.7 INSTALLATION OF ODP WALL (2)(In case pipe shall be buried in the wall)

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    59/101

    Page 59 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    6.8 FORM FOR CORE ASSIGNMENT

    6.8.1 FEEDER CABLE (STAR TOPOLOGY: 24 CORE BASE)

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    60/101

    Page 60 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    6.8.2 FEEDER CABLE (STAR TOPOLOGY: 12 CORE BASE)

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    61/101

    Page 61 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    6.8.3 FEEDER CABLE (RING TOPOLOGY)

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    62/101

    Page 62 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    6.8.4 DISTRIBUTION CABLE

    No. Port No. PORT No.

    CORE ASSIGNMENT DIAGRAM (DISTRIBUTION CABLE)

    CAPACITY -CORE

    OTB

    Port No.

    SPLITTER 1:4CORE No.

    ODC

    PORT No.

    ODC TRAY

    DISTRIBUTION CABLE No.

    4

    3

    4

    1

    2

    D-

    2

    3

    4

    1

    2

    3

    4

    1

    2

    3

    3

    4

    1

    2

    3

    4

    1

    2

    1

    19

    20

    21

    22

    23

    24

    13

    14

    15

    16

    17

    18

    7

    8

    9

    10

    11

    12

    1

    2

    3

    4

    5

    6

    FEEDER SEGMENT

    1

    2

    3

    4

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    STO

    11

    12

    5

    6

    7

    8

    DISTRIBUTION SEGMENT

    ODP No.ODP No.ODP No.ODP No.

    NAMA LOKASI

    9

    10

    11

    12

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    63/101

    Page 63 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    TipeProduct:ODC-C-144

    Tgl.Instalasi

    NamaLokasi

    NamaInstaller

    Category

    Items

    1.Aksesoris

    Cableband(M)

    Cableband(L)

    Spira

    lTube

    Compound

    Cabletie

    Asse

    mblymanual

    PVC

    tape

    2.PondasiODC

    Baut

    expansiontidakkendur

    3.LubangKabelMasu

    k(Feeder&Distribusi)

    4.Cableclamp

    Clam

    puntuktensionMembertidakkendur

    CableBandtidakKendur

    5.RuteLooseTube

    Tidak

    adasmallbending(diamete

    r>60)

    tidak

    terjepitdengantutuptray

    Tidak

    adasmallbending(diamete

    r>60)

    tidak

    terjepitdengantutuptray

    7.RutePigtaildalamTray

    Arah

    Rute(bentukS)

    Tidak

    adasmallbending(diamete

    r>60)

    tidak

    terjepitdengantutuptray

    8.InstalasiSplittermo

    dul

    rutes

    esuaipetunjukmanual

    Tidak

    adasmallbending(diamete

    r>60)

    tidak

    salingtersangkutdanmudah

    diurai

    10.SCconnectorpatching

    Kone

    ktortercolokdenganbenar(sampaibunyiklik)

    diperiksaoleh

    :

    (Sitemanager)

    Catatan

    Arah

    danPosisiSplitterharusben

    ar(Input:bawah;

    Output:atas)

    Peng

    gunaanCompoundharusrapat(tidakadacelah)

    InstallationCheckSheet

    pcs

    pcs

    pcs

    pc

    pcs

    9.RutekabeldariSplitterkeTray

    pc

    pc

    Che

    ck

    *2buahkunciODC

    harussudah

    diterimasitemanager

    *cek

    sisaaksesorisyangdiperlukan

    untukinstalasikabe

    lberikutnyadanuntuk

    maintenance

    6.RuteFiberdidalam

    Tray

    6.9 INSTALLATION CHECK SHEET

    6.9.1 INSTALLATION CHECK SHEET: ODC-C-144

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    64/101

    Page 64 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    6.9.2 INSTALLATION CHECK SHEET: ODC-C-288TipeProduk:ODC-C-288

    Tgl.Instalasi

    NamaLokasi

    NamaInstaller

    Category

    Items

    1.Aksesoris

    Cable

    band(M)

    Cable

    band(L)

    SpiralTube

    Compound

    Cable

    tie

    Assem

    blymanual

    PVCtape

    2.PondasiODC

    Bautexpansiontidakkendur

    3.LubangKabelMasuk(Feeder&Distribusi)

    4.Cableclamp

    Clamp

    untuktensionMembertidakkendur

    Cable

    BandtidakKendur

    5.RuteLooseTube

    Tidakadasmallbending(diameter

    >60)

    tidakterjepitdengantutuptray

    Tidakadasmallbending(diameter

    >60)

    tidakterjepitdengantutuptray

    7.RutePigtaildalamTray

    ArahR

    ute(bentukS)

    Tidakadasmallbending(diameter

    >60)

    tidakterjepitdengantutuptray

    8.InstalasiSplittermod

    ul

    rutese

    suaipetunjukmanual

    Tidakadasmallbending(diameter

    >60)

    tidaks

    alingtersangkutdanmudahd

    iurai

    10.SCconnectorpatching

    Konektortercolokdenganbenar(sa

    mpaibunyiklik)

    Diperiksaoleh

    (Sitemanager)

    Catatan

    Arahd

    anPosisiSplitterharusbenar(Input:kiri;

    Output:kanan)

    *2buahkunciODCharussudah

    diterimasitemanage

    r

    InstallationCheckSheet

    Checkp

    cspcs

    pcspc

    pcs

    *cek

    sisaaksesoris

    yangdiperlukan

    untukinstalasikabel

    berikutnyadanuntuk

    maintenance

    6.RuteFiberdidalamTray

    9.RutekabeldariSplitterkeTray

    pcpc

    Pengg

    unaanCompoundharusrapa

    t(tidakada

    celah)

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    65/101

    Page 65 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    ProductType:ODP-CA-8/16-WP

    InstallationDate:

    InstallationSite:

    InstallerName:

    Category

    Items

    Check

    1.Accessory

    Cabletie

    pc

    s

    Expansionscrew

    sets

    Dropcablefixingclamp

    pc

    s

    Bukumanual

    pc

    PVCtape

    pc

    2.InstalasiSplitter

    Arah:inp

    ut:kiri;output:kanan,label

    terlihat

    PosisiSp

    litter:No1palingatas

    Tidakada

    smallbending(diameter>60

    )

    KabelTidakterjepitatautersangkutjikadibuka

    PosisiKonektor

    4.LubangTempatkabelmasuk

    5.clampKabel

    Clampun

    tukTensionmemberTidakkendur

    Clampun

    tukkabeltidakkendur

    6.RutekabelSCPTPas

    sthrough

    Tidakada

    smallbending(diameter>60

    )

    TidakterjepitdantersangkutjikaODPd

    ibuka

    7.ClampdanruteSCPT

    yangditerminasi

    pastikanpenggunaankabelTiesditigatitik

    Tidakada

    smallbending(diameter>60

    )

    tidakterje

    pitdantersangkutjikaODPdibuka

    8.RuteFibersetelahSplicing

    Tidakada

    smallbending(diameter>60

    )

    tidakterjepitdantersangkutjikaODPdibuka

    Diperiksaoleh:

    (Sitemanager)

    Catatan

    pemasangantempatmasukkabelharus

    rata,tidakmiring

    Installatio

    nChecksheet

    *1buahkunciODPharussudah

    diterimasitemanager

    tidakada

    celah(penggunaansolasiatau

    grommet

    harusdap

    atmenutupcelah)

    adadisebelahkanan,

    BariskonektorpalingbawahuntukSplitterno.1

    *ceksisaaksesorisya

    ngdiperlukan

    untukinstalasikabelberikutnyadanuntuk

    maintenance

    3.instalasioutputSplitterpadapanel

    Adapter

    6.9.3 INSTALLATION CHECK SHEET: ODP-PL/PW-8/16

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    66/101

    Page 66 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    Pro

    ductT

    ype:T

    C-S

    M-144

    Installa

    tionD

    ate:

    Installa

    tion

    Site:

    InstallerN

    am

    e:

    Category

    Item

    s

    1.Ak

    sesoris

    Cable

    band(M)

    Cable

    band(L)

    Pla

    stic

    Tube

    Screw

    andn

    ut

    Cable

    tie

    Buk

    uM

    anual

    PV

    Cta

    pe

    2.

    Clam

    pk

    abel

    Clam

    p

    untukT

    en

    sionm

    em

    berTid

    ak

    ken

    dur

    CableB

    andtidakk

    en

    dur

    3.R

    utek

    abelL

    oosetub

    e

    Tid

    ak

    a

    dasm

    all

    ben

    din

    g

    (diam

    eter>

    60)

    kabelT

    idak

    terje

    pit

    atauters

    an

    gk

    utjika

    traydile

    pas

    Tid

    ak

    a

    dasm

    all

    ben

    din

    g

    (diam

    eter>

    60)

    Tid

    ak

    terje

    pit

    atauters

    an

    gk

    utjikacov

    ertraydi

    buk

    a

    5.R

    ute

    Pig

    tail

    padaTra

    y

    Rutem

    emben

    tukh

    uruf

    S

    Tid

    ak

    a

    dasm

    all

    ben

    din

    g

    (diam

    eter>

    60)

    Tid

    akT

    erjepit

    atau

    ters

    an

    gk

    utjikacover

    traydib

    uk

    a

    Dip

    erik

    saoleh

    (Sitem

    an

    ager)

    Catatan

    pcpc

    Ch

    eck

    4.R

    utek

    abel

    dalamtra

    y

    *Cek

    sisaaksesoris

    yangdiperlukan

    untukinstalasikabel

    berikutnyadanuntuk

    maintenance

    Installa

    tion

    Ch

    eck

    Sh

    eet

    p

    cs

    p

    cs

    p

    cs

    sets

    p

    cs

    6.9.4 INSTALLATION CHECK SHEET: TC-SM-144

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    67/101

    Page 67 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    6.10 LIST OF ASSEMBLY UNIT DESIGNATOR (1/6)

    A

    KABEL&PENYAMB

    UNGAN

    1

    DC-OF-SM-12D

    PengadaandanpemasanganKabelD

    uctFiberOptik

    SingleMode12coreG652D(termasukperijinan

    PEMDA,PU,Warga)

    meter

    2

    DC-OF-SM-24D

    Idem24core

    meter

    3

    DC-OF-SM-48D

    Idem48core

    meter

    4

    DC-OF-SM-96D

    Idem96core

    meter

    5

    DC-OF-SM-144D

    Idem144core

    meter

    6

    DC-OF-SM-288D

    Idem288core

    meter

    7

    DC-OF-SM-432D

    Idem432core

    meter

    8

    DC-OF-SM-960D

    Idem960core

    meter

    9

    AC-OF-SM-12D

    PengadaandanpemasanganKabelU

    daraFiber

    OptikSingleMode12coreG652D(termasuk

    perijinanPEMDA,PU,Warga)

    meter

    10

    AC-OF-SM-24D

    Idem24core

    meter

    11

    AC-OF-SM-48D

    Idem48core

    meter

    12

    AC-OF-SM-96D

    Idem96core

    meter

    13

    DC-OF-SM-12C

    PengadaandanpemasanganKabelD

    uctFiberOptik

    SingleMode12coreG655C(termasukperijinan

    PEMDA,PU,Warga)

    meter

    14

    DC-OF-SM-24C

    Idem24core

    meter

    15

    DC-OF-SM-48C

    Idem48core

    meter

    16

    DC-OF-SM-96C

    Idem96core

    meter

    17

    AC-OF-SM-12C

    PengadaandanpemasanganKabelU

    daraFiber

    OptikSingleMode12coreG655C

    (termasuk

    perijinanPEMDA,PU,Warga)

    meter

    18

    AC-OF-SM-24C

    Idem24core

    meter

    19

    AC-OF-SM-48C

    Idem48core

    meter

    20

    AC-OF-SM-96C

    Idem96core

    meter

    21

    DC-OF-SM-8-SC

    PengadaandanpemasanganKabelD

    uctFiberOptik

    SingleMode8coreG652D,"Easyto

    split"

    (termasukperijinanPEMDA,PU,War

    ga)

    meter

    22

    DC-OF-SM-12-SC

    Idem12Core

    meter

    23

    DC-OF-SM-24-SC

    Idem24Core

    meter

    24

    AC-OF-SM-8-SC

    PengadaandanpemasanganKabelU

    daraFiber

    OptikSingleMode8coreG652D,"E

    asytosplit"

    (termasukperijinanPEMDA,PU,War

    ga)

    meter

    25

    AC-OF-SM-12-SC

    Idem12Core

    meter

    26

    AC-OF-SM-24-SC

    Idem24Core

    meter

    27

    SC-OF-SM-24

    Pengadaandanpemasanganalatsam

    bung(cabang/

    lurus)untukFiberOptikkapasitas12-24core

    pcs

    28

    SC-OF-SM-48

    Idem12-48core

    pcs

    29

    SC-OF-SM-96

    Idem12-96core

    pcs

    30

    SC-OF-SM-144

    Idem12-144core

    pcs

    31

    SC-OF-SM-288

    Idem12-288core

    pcs

    32

    OS-SM-1Eks

    PenyambunganKabelOptikSingleModekap1core

    dengancarafusionsplice

    core

    33

    OS-SM-6

    PenyambunganKabelOptikSingleModekap6core

    dengancarafusionsplice

    pcs

    34

    OS-SM-12

    Idemkap12core

    pcs

    35

    OS-SM-24

    Idemkap24core

    pcs

    36

    OS-SM-48

    Idemkap48core

    pcs

    37

    OS-SM-96

    Idemkap96core

    pcs

    38

    OS-SM-144

    Idemkap144core

    pcs

    39

    OS-SM-288

    Idemkap288core

    pcs

    40

    AB-OF-SM-2D

    PengadaandanpemasanganAirBlo

    wnCableOptik,

    SingleMode2core,G652D(termasukperijinan

    PEMDA,PU,Warga)

    meter

    41

    AB-OF-SM-4D

    Idem4core

    meter

    42

    AB-OF-SM-8D

    Idem8core

    meter

    43

    AB-OF-SM-12D

    Idem12core

    meter

    44

    AB-OF-SM-24D

    Idem24core

    meter

    45

    AB-OF-SM-48D

    Idem48core

    meter

    46

    AB-OF-SM-72D

    Idem72core

    meter

    47

    AB-OF-SM-96D

    Idem96core

    meter

    48

    AB-OF-SM-144D

    Idem144core

    meter

    49

    GC-OF-SM-1D

    PengadaandanpemasanganDropC

    ableFODuct

    /underground1CoreSingleMode,G.657

    meter

    50

    GC-OF-SM-2D

    idem2core

    51

    HC-OF-SM-1D

    PengadaandanpemasanganDropC

    ableFOatas

    tanah/aerial1CoreSingleMode,G.6

    57

    meter

    52

    HC-OF-SM-2D

    idem2core

    meter

    53

    IC-OF-SM-1D

    PengadaandanpemasanganIndoorCableFOSingle

    Mode1core,G.657

    meter

    54

    IC-OF-SM-2D

    Idem2core

    meter

    KETERANGAN

    NO

    DESIGNATOR

    URAIAN

    PEKERJAAN

    SATUAN

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

  • 7/24/2019 Handbookforftthospv1 150225032334 Conversion Gate02

    68/101

    Page 68 HANDBOOK for FTTH-OSP v 1.0 (June 2013)CopyrightFujikura Ltd./Y.N

    6.10 LIST OF ASSEMBLY UNIT DESIGNATOR (2/6)

    55

    PC-SC-2-BI

    Patchcord2meter,BendInsensitive(SC/APCTo

    SC/UPC)dariRosetkeONT,G.657

    pcs

    56

    PC-SC-5-BI

    Patchcord5meter,BendInsensitive(SC/APCTo

    SC/UPC)dariRosetkeONT,G.657

    pcs

    57

    PC-SC-2

    Patchcord2meter,(SC/APCToSC/APC),G.657

    pcs

    58

    PC-SC-5

    Patchcord5meter(SC/APCToSC/APC),G.657

    pcs

    59

    PC-SC-10

    Patchcord10meter(SC/APCToSC

    /APC),G.657

    pcs

    60

    PC-SC-20

    Patchcord20meter(SC/APCToSC

    /APC),G.657

    pcs

    61

    PC-FC-20

    Patchcord20meter(FC/APCToFC/APC),G.657

    pcs

    62

    PC-SC-30

    Patchcord30meter(SC/APCToSC

    /APC),G.657

    pcs

    63

    PC-FC-30

    Patchcord30meter(FC/APCToFC/APC),G.657

    pcs

    64

    PC-SC-40

    Patchcord40meter(SC/APCToSC

    /APC),G.657

    pcs

    65

    PC-FC-40

    Patchcord40meter(FC/APCToFC/APC),G.657

    pcs

    66

    PC-SC-2

    Patchcord2meter,(SC/UPCToSC/UPC),G.657

    pcs

    67

    PC-SC-5

    Patchcord5meter(SC/UPCToSC/UPC),G.657

    pcs

    68

    PC-SC-10

    Patchcord10meter(SC/UPCToSC

    /UPC),G.657

    pcs

    69

    PC-SC-20

    Patchcord20meter(FC/UPCToFC/UPC),G.657

    pcs

    70

    PC-FC-20

    Patchcord20meter(SC/UPCToSC

    /UPC),G.657

    pcs

    71

    PC-SC-30

    Patchcord20meter(FC/UPCToFC/UPC),G.657

    pcs

    72

    PC-FC-30

    Patchcord30meter(SC/UPCToSC

    /UPC),G.657

    pcs

    73

    PC-SC-40

    Patchcord40meter(FC/UPCToFC/UPC),G.657

    pcs

    74

    PC-FC-40

    Patchcord40meter(SC/UPCToSC

    /UPC),G.657

    pcs

    75

    PC-FC-40

    Patchcord40meter(FC/UPCToFC/UPC),G.657

    pcs

    76

    ODC-C-144Splitter

    PengadaandanpemasangankabinetODC(Outdoor)

    kap144coredenganspaceuntuksplitermodular

    termasukmaterialadaptorSC/UPC,pigtail,pondasi

    berlapiskeramik,lantaikerja,patokp

    engaman(5

    buah),berikutpelabelan

    pcs

    77

    ODC-C-288Splitter

    PengadaandanpemasangankabinetODC(Outdoor)

    kap288coredenganspaceuntuksplitermodular

    termasukmaterialadaptorSC/UPC,pigtail,pondasi

    berlapiskeramik,lantaikerja,patokp

    engaman(5

    buah),berikutpelabelan

    pcs

    78

    ODC-C-576Splitter

    PengadaandanpemasangankabinetODC(Outdoor)

    kap576coredenganspaceuntuksplitermodular

    termasukmaterialadaptorSC/UPC,pigtail,pondasi

    berlapiskeramik,lantaikerja,patokp

    engaman(5

    buah),berikutpelabelan

    pcs

    79

    ODC-C-48Splitter

    PengadaandanpemasanganODC-P

    ole(Outdoor)

    withspaceforpassivespliter,adaptorSC/UPC

    kap

    48core,berikutpelabelan

    pcs

    80

    ODP-CU-8

    PengadaandanpemasanganODPty

    peClosure

    UndergroundKap8corewithspaceforsplitter,

    AdapterSC/UPC

    pcs

    81

    ODP-CU-16

    idem16core

    pcs

    82

    ODP-CA-8

    PengadaandanpemasanganODPty

    peClosure

    AerialKap8coreberikutspacepasiv

    espliter(1:8),

    adapterSC/UPC,berikutpelabelan

    pcs

    83

    ODP-CA-16

    PengadaandanpemasanganODPty

    peClosure

    AerialKap16coreberikutspace2pasivespliter

    (1:8),adapterSC/UPC,berikutpelabe

    lan

    pcs

    84

    ODP-A-8

    PengadaandanpemasanganODPty

    peIndoor/wall

    Kap8coreberikutspacepasivespliter(1:8),adapter

    SC/UPC,berikutpelabelan

    pcs

    85

    ODP-A-16

    PengadaandanpemasanganODPty

    peIndoor/wall

    Kap16coreberikutspace2pasives

    pliter(1:8),

    adapterSC/UPC,berikutpelabelan

    pcs

    86

    ODP-A-24

    PengadaandanpemasanganODPty

    peIndoor/wall

    Kap24coreberikutspace3pasives

    pliter(1:8),

    adapterSC/UPC,berikutpelabelan

    pcs

    87

    ODP-A-48

    PengadaandanpemasanganODPty

    peIndoor/wall

    Kap48coreberikutspace6pasives

    pliter(1:8),

    adapterSC/UPC,berikutpelabelan

    pcs

    88

    ODP-PL-8

    PengadaandanpemasanganODP(Pilar)kap8

    coretermasukpigtail,berikutspace1

    splitter(1:8),

    pelabelan.

    pcs

    89

    ODP-PL-16

    PengadaandanpemasanganODP(Pilar)kap16

    coretermasukpigtail,berikutspace2

    splitter(1:8),

    pelabelan.

    pcs

    KETERANGAN

    NO

    DESIGNATOR

    URAIAN

    PEKERJAA

    N

    SATUAN

    HANDBOOK for

    FTTH OSP (PT TELKOM INDONESIA)

  • 7/24/


Recommended