CKT. NO. POLE TRIP A POLE C TRIP BREAKER BREAKER PHASE CKT. NO. 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 6 3 4 1 2 LOAD DESIGNATION LOAD DESIGNATION PANELBOARD SCHEDULE B RATING: DESIGNATION: REMARKS: SERVICE ENTRANCE RATED 225 AMPS MAIN: 150A MCB SERVICE: 9 : MOUNTING: SURFACE S.C. RATING: 30,000A RMS SYM. PPH1 LOCATION: ELECTRICAL CABINET - - 100 EXISTING PANEL SPACE SPACE SPARE SPARE 20 SPARE 20 RECEPTACLES 20 RECEPTACLES 20 RECEPTACLES 20 RECEPTACLES 20 RECEPTACLES 20 RECEPTACLES 20 RECEPTACLES 20 CABINET LIGHTING AND RECEPTACLE SPACE SPACE SPACE SPACE 20 RECEPTACLES 20 RECEPTACLES 20 RECEPTACLES 30 - 30 TVSS 30 - 20 RECEPTACLES 20 RECEPTACLES 20 SITE LIGHTING 20 SITE LIGHTING 20 SITE LIGHTING ELECTRICAL ONE LINE DIAGRAM UTILITY METER GFI S LIGHT FIXTURE WEATHERPROOF ELECTRICAL ENCLOSURE ON CONCRETE PAD. REFER TO DETAIL ON DRAWING E1.02 FOR ADDITIONAL REQUIREMENTS 2"C., 4#2/0 & 1#6GND ELECTRONIC TIME CLOCK AND MANUAL TIME ADJUSTABLE OVERIDE SWITCH QUANTITY AS REQUIRED. M REFER TO DRAWING E1.01 FOR CONDUIT AND WIRE REQUIREMENTS AND ROUTING EXISTING UTILITY RISER POLE UNDERGROUND ELECTRIC LINE PP-1,3 ELECTRICAL SYMBOL LIST WP WEATHERPROOF POLYVINYL CHLORIDE CONDUIT RIGID GALVANIZED STEEL CONDUIT XFMR RSC V TRANSFORMER VOLTS PVC NTS NIC PNL NOT TO SCALE PANELBOARD NOT IN CONTRACT MECHANICAL CONTRACTOR GROUND FAULT INTERRUPTER MAIN CIRCUIT BREAKER MTD MCB MLO MC KW MOUNTED KILOWATT MAIN LUGS ONLY GND JB GFI GC JUNCTION BOX GROUND GENERAL CONTRACTOR ELECTRICAL CONTRACTOR ELECTRIC METALLIC TUBING CONDUIT C EMT CKT CB EC CIRCUIT CIRCUIT BREAKER BKR A AMPERE BREAKER RACEWAY AND WIRING MISCELLANEOUS AMPERE FRAME AF AMPERE TRIP AT LIGHTING 1. DRAWINGS ARE DIAGRAMMATIC ONLY. THE EXACT LOCATION, MOUNTING HEIGHTS, SIZE OF EQUIPMENT AND ROUTING OF RACEWAYS SHALL BE COORDINATED AND DETERMINED IN THE FIELD. 2. WORK SHALL CONFORM TO THE MASSACHUSETTS ELECTRICAL CODE AND MASSACHUSETTS BUILDING CODE AND REQUIREMENTS OF LOCAL AUTHORITIES HAVING JURISDICTION. 3. THE WORD "CONTRACTOR" AS USED IN THE "ELECTRICAL WORK" SHALL MEAN THE ELECTRICAL CONTRACTOR. 4. CONTRACTOR SHALL PAY FOR ALL PERMITS, INSURANCE AND TESTS, AND SHALL PROVIDE LABOR AND MATERIAL TO COMPLETE THE ELECTRICAL WORK SHOWN. 5. CONTRACTOR SHALL PAY ELECTRIC UTILITY COMPANY BACKCHARGES AND PROVIDE COORDINATION WITH SAME. 6. EXCEPT AS OTHERWISE NOTED, THE ELECTRICAL WORK SHALL INCLUDE PANELBOARDS, CIRCUIT BREAKERS, FEEDERS, WIRING, RACEWAYS, LIGHTING FIXTURES, DEVICES, SAFETY SWITCHES, MOUNTING AND WIRING, TRANSFORMERS AND CONNECTIONS NECESSARY TO OPERATE ALL EQUIPMENT. 7. DURING CONSTRUCTION, THE ELECTRICAL CONTRACTOR SHALL KEEP HIS PORTION OF THE WORK NEAT, CLEAN AND ORDERLY. 8. ALL SYSTEMS SHALL BE TESTED FOR SHORT CIRCUIT AND GROUNDS PRIOR TO ENERGIZING AND ANY DEFECTS SHALL BE CORRECTED. 9. ALL CUTTING, PATCHING AND TRENCHING REQUIRED FOR ELECTRICAL WORK SHALL BE INCLUDED AS PART OF THIS SECTION. 10. COMPLETE SHOP DRAWINGS SHALL BE SUBMITTED FOR ELECTRICAL EQUIPMENT. WHERE SPECIFIED, ELECTRICAL EQUIPMENT IS SUBSTITUTED. THE ELECTRICAL CONTRACTOR SHALL SUBMIT COMPLETE SPECIFICATIONS ON THE SUBSTITUTE AS WELL AS THE ITEM ORIGINALLY SPECIFIED. 11. MATERIALS SHALL BE SPECIFICATION GRADE AND UL LISTED. 12. WHERE MATERIAL IS CALLED OUT IN THE LEGEND BY MANUFACTURER, TYPE OR CATALOG NUMBER, SUCH DESIGNATIONS ARE TO ESTABLISH STANDARDS OR DESIRED QUALITY. ACCEPTANCE OR REJECTIONS OF PROPOSED SUBSTITUTIONS SHALL BE SUBJECT TO THE APPROVAL OF THE OWNER. 13. WORK SHALL BE COORDINATED WITH EXISTING CONDITIONS TO ELIMINATE INTERFERENCES. 14. ELECTRICAL WORK SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM DATE OF WHICH SYSTEM IS PUT INTO SERVICE. 15. WORK SHALL BE GROUNDED IN ACCORDANCE WITH CODE REQUIREMENTS. COMPLETE EQUIPMENT (INSULATED GREEN WIRE) GROUNDING SYSTEM SHALL BE INSTALLED. 16. WIRING METHODS: A. BELOW GRADE WIRING SHALL BE SCHEDULE 40 PVC. 19. PANELBOARDS SHALL BE DEAD FRONT, THERMAL MAGNETIC BOLT-ON CIRCUIT BREAKER TYPE, DESIGNED FOR SURFACE MOUNTING AS INDICATED ON PLAN, AND HAVING CONNECTIONS TO 120/240 VOLT, 3 PHASE, 4 WIRE SERVICE. ALL BUS BARS SHALL BE COPPER. CABINETS SHALL BE MADE OF CODE GAUGE GALVANIZED SHEET STEEL, WITH A MINIMUM OF 4 INCH GUTTERS, DOOR IN DOOR CONSTRUCTION, LOCKED DOOR, AND FLUSH HINGES. TYPEWRITTEN INDEX SHALL BE MOUNTED ON DOOR INSIDE TRANSPARENT COVER INDICATING LOAD SERVED. PANELS SHALL INCLUDE SEPARATE EQUIPMENT GROUND BUS. 20. CONDUIT RUNS AS SHOWN ON THE PLANS ARE DIAGRAMMATIC ONLY; EXACT LOCATION AND METHOD OF SUPPORT SHALL BE DETERMINED IN THE FIELD. 21. CONTRACTOR SHALL CHECK EXISTING CONDITIONS TO DETERMINE EXACT EXTENT OF WORK TO BE PERFORMED PRIOR TO BIDDING. DIMENSIONS RELEVANT TO EXISTING WORK SHALL BE VERIFIED IN THE FIELD. 22. PROVIDE AS-BUILT "CADD" DRAWINGS AT THE COMPLETION OF THE PROJECT. 23. ALL EXCAVATION AND BACKFILL SHALL BE BY THE ELECTRICAL CONTRACTOR. GENERAL ELECTRICAL NOTES : HANDHOLE SEE DETAIL ON E1.3 THIS DRAWING -HOMERUN TO PANELBOARD, NUMBER OF SLASH MARKS INDICATES NUMBER OF #12 AWG CONDUCTORS IN MINIMUM 3/4" CONDUIT. NO SLASH MARKS INDICATE 2#12 & 1#12G, 3/4"C UNLESS NOTED OTHERWISE. -GREEN GROUND CONDUCTOR IS NOT INDICATED BUT SHALL BE INCLUDED IN EACH RACEWAY. SIZE SHALL BE #12 UNLESS INDICATED OTHERWISE. -HOMERUNS TO PANELBOARDS SHALL HAVE A MAXIMUM OF THREE PHASE CONDUCTORS (ONE PER PHASE) PLUS NEUTRAL AND GROUND CONDUCTOR IN EACH CONDUIT. ABBREVIATIONS DEMOLITION NOTES: 1. THE ELECTRICAL CONTRACTOR WILL DEMOLISH THE EXISTING ELECTRICAL SYSTEMS ASSOCIATED WITH ALL EXISTING EQUIPMENT TO BE REMOVED. THE ELECTRICAL CONTRACTOR IS TO DEACTIVATE, DISCONNECT AND REMOVE THOSE SYSTEMS WHICH WILL BE DEMOLISHED. THE ELECTRICAL CONTRACTOR WILL REMOVE AND DISPOSE OF ALL ELECTRICAL SYSTEM MATERIALS INCLUDING DEVICES, FIXTURES, RACEWAYS, CABLE AND APPURTENANCES. 2. MAKE ANY NECESSARY RE-CIRCUITING, EXTENSIONS OF EXISTING CIRCUITS AND RELOCATIONS REQUIRED TO PROPERLY RE-ENERGIZE REMAINING EXISTING SERVICES OR EQUIPMENT THAT MAY BE INTERFERED WITH BY NEW CONSTRUCTION, REMOVALS OR RELOCATIONS. ALL SHUT DOWNS TO RELOCATE ACTIVE FEEDERS OR BRANCH CIRCUITS WILL BE PERFORMED ON HOURS MUTUALLY AGREED TO WITH THE OWNER. 3. PRIOR TO REMOVAL OF EQUIPMENT, CONFIRM THAT FEEDER AND BRANCH CIRCUITS ARE NO LONGER ACTIVE. SHOULD IT BE DISCOVERED THE FEEDER OR BRANCH CIRCUITS ARE ACTIVE, NOTIFY THE ENGINEER IMMEDIATELY FOR DIRECTION. 4. EXISTING ABANDONED HIGH AND LOW TENSION SYSTEMS ARE TO BE REMOVED. UNDER NO CIRCUMSTANCES ARE ABANDONED HIGH AND LOW TENSION SYSTEMS OR SYSTEM COMPONENTS TO REMAIN. GFI 2"C., 4#2/0 & 1#6GND XM XR XM TVSS WP A 4 XM 4 LOCKABLE FUSED DISCONNECT SWITCH 6 4 20 20 08/09/2017 Date: BURLINGTON COMMONS CENTER STREET BURLINGTON, MA 01803 Drawn By: Reviewed By: Approved By: Drawing Title: Sheet Number: Seal: Revisions: No. Date Description Project: TOWN OF BURLINGTON, MA Consultants: W&S Project No: 2170150 COPYRIGHT 2017 WESTON & SAMPSON Scale: 978.532.1900 www.westonandsampson.com 800.SAMPSON Issued For: Weston & Sampson Engineers, Inc. Five Centennial Drive, Peabody, MA 01960 ELECTRICAL LEGEND, ABBREVIATIONS AND GENERAL NOTES E1.00 NONE DNM RFM RFM
Transcript

CKT.

NO.

POLETRIP A POLEC TRIP

BREAKER BREAKERPHASE

CKT.

NO.

29 30

27 28

25 26

23 24

21 22

19 20

17 18

15 16

13 14

11 12

9 10

7 8

5 6

3 4

1 2

LOAD

DESIGNATION

LOAD

DESIGNATION

PANELBOARD SCHEDULE

B

RATING:

DESIGNATION: REMARKS: SERVICE ENTRANCE RATED

225 AMPS

MAIN: 150A MCB

SERVICE: 120/208V, 3Ø, 4W

MOUNTING: SURFACE

S.C. RATING: 30,000A RMS SYM.PPH1

LOCATION: ELECTRICAL CABINET

--

100EXISTING PANEL

SPACE

SPACE

SPARE

SPARE

20SPARE

20RECEPTACLES

20RECEPTACLES

20RECEPTACLES

20RECEPTACLES

20RECEPTACLES

20RECEPTACLES

20RECEPTACLES

20CABINET LIGHTING AND RECEPTACLE

SPACE

SPACE

SPACE

SPACE

20

RECEPTACLES

20

RECEPTACLES

20

RECEPTACLES

30

-

30

TVSS

30

-

20

RECEPTACLES

20

RECEPTACLES

20

SITE LIGHTING

20

SITE LIGHTING

20SITE LIGHTING

ELECTRICAL ONE LINE DIAGRAM

UTILITY METER

GFI

S

LIGHT FIXTURE

WEATHERPROOF ELECTRICALENCLOSURE ON CONCRETE PAD.REFER TO DETAIL ON DRAWINGE1.02 FOR ADDITIONALREQUIREMENTS

2"C., 4#2/0 & 1#6GND

ELECTRONIC TIME CLOCK ANDMANUAL TIME ADJUSTABLEOVERIDE SWITCH QUANTITY ASREQUIRED.

M

REFER TO DRAWING E1.01FOR CONDUIT AND WIRE

REQUIREMENTS ANDROUTING

EXISTING UTILITYRISER POLE

UNDERGROUND ELECTRIC LINE

PP-1,3

ELECTRICAL SYMBOL LIST

WP WEATHERPROOF

POLYVINYL CHLORIDE CONDUIT

RIGID GALVANIZED STEEL CONDUIT

XFMR

RSC

V

TRANSFORMER

VOLTS

PVC

NTS

NIC

PNL

NOT TO SCALE

PANELBOARD

NOT IN CONTRACT

MECHANICAL CONTRACTOR

GROUND FAULT INTERRUPTER

MAIN CIRCUIT BREAKER

MTD

MCB

MLOMC

KW

MOUNTED

KILOWATT

MAIN LUGS ONLY

GND

JB

GFI

GC

JUNCTION BOX

GROUND

GENERAL CONTRACTOR

ELECTRICAL CONTRACTOR

ELECTRIC METALLIC TUBING

CONDUITC

EMT

CKT

CB

EC

CIRCUIT

CIRCUIT BREAKER

BKR

A AMPERE

BREAKER

RACEWAY AND WIRING

MISCELLANEOUS

AMPERE FRAMEAF

AMPERE TRIPAT

LIGHTING

1. DRAWINGS ARE DIAGRAMMATIC ONLY. THE EXACT LOCATION, MOUNTING HEIGHTS,

SIZE OF EQUIPMENT AND ROUTING OF RACEWAYS SHALL BE COORDINATED AND

DETERMINED IN THE FIELD.

2. WORK SHALL CONFORM TO THE MASSACHUSETTS ELECTRICAL CODE AND

MASSACHUSETTS BUILDING CODE AND REQUIREMENTS OF LOCAL AUTHORITIES

HAVING JURISDICTION.

3. THE WORD "CONTRACTOR" AS USED IN THE "ELECTRICAL WORK" SHALL MEAN THE

ELECTRICAL CONTRACTOR.

4. CONTRACTOR SHALL PAY FOR ALL PERMITS, INSURANCE AND TESTS, AND SHALL

PROVIDE LABOR AND MATERIAL TO COMPLETE THE ELECTRICAL WORK SHOWN.

5. CONTRACTOR SHALL PAY ELECTRIC UTILITY COMPANY BACKCHARGES AND PROVIDE

COORDINATION WITH SAME.

6. EXCEPT AS OTHERWISE NOTED, THE ELECTRICAL WORK SHALL INCLUDE

PANELBOARDS, CIRCUIT BREAKERS, FEEDERS, WIRING, RACEWAYS, LIGHTING

FIXTURES, DEVICES, SAFETY SWITCHES, MOUNTING AND WIRING, TRANSFORMERS

AND CONNECTIONS NECESSARY TO OPERATE ALL EQUIPMENT.

7. DURING CONSTRUCTION, THE ELECTRICAL CONTRACTOR SHALL KEEP HIS PORTION

OF THE WORK NEAT, CLEAN AND ORDERLY.

8. ALL SYSTEMS SHALL BE TESTED FOR SHORT CIRCUIT AND GROUNDS PRIOR TO

ENERGIZING AND ANY DEFECTS SHALL BE CORRECTED.

9. ALL CUTTING, PATCHING AND TRENCHING REQUIRED FOR ELECTRICAL WORK SHALL

BE INCLUDED AS PART OF THIS SECTION.

10. COMPLETE SHOP DRAWINGS SHALL BE SUBMITTED FOR ELECTRICAL EQUIPMENT.

WHERE SPECIFIED, ELECTRICAL EQUIPMENT IS SUBSTITUTED. THE ELECTRICAL

CONTRACTOR SHALL SUBMIT COMPLETE SPECIFICATIONS ON THE SUBSTITUTE AS

WELL AS THE ITEM ORIGINALLY SPECIFIED.

11. MATERIALS SHALL BE SPECIFICATION GRADE AND UL LISTED.

12. WHERE MATERIAL IS CALLED OUT IN THE LEGEND BY MANUFACTURER, TYPE OR

CATALOG NUMBER, SUCH DESIGNATIONS ARE TO ESTABLISH STANDARDS OR

DESIRED QUALITY. ACCEPTANCE OR REJECTIONS OF PROPOSED SUBSTITUTIONS

SHALL BE SUBJECT TO THE APPROVAL OF THE OWNER.

13. WORK SHALL BE COORDINATED WITH EXISTING CONDITIONS TO ELIMINATE

INTERFERENCES.

14. ELECTRICAL WORK SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM

DATE OF WHICH SYSTEM IS PUT INTO SERVICE.

15. WORK SHALL BE GROUNDED IN ACCORDANCE WITH CODE REQUIREMENTS.

COMPLETE EQUIPMENT (INSULATED GREEN WIRE) GROUNDING SYSTEM SHALL BE

INSTALLED.

16. WIRING METHODS:

A. BELOW GRADE WIRING SHALL BE SCHEDULE 40 PVC.

19. PANELBOARDS SHALL BE DEAD FRONT, THERMAL MAGNETIC BOLT-ON CIRCUIT

BREAKER TYPE, DESIGNED FOR SURFACE MOUNTING AS INDICATED ON PLAN, AND

HAVING CONNECTIONS TO 120/240 VOLT, 3 PHASE, 4 WIRE SERVICE. ALL BUS BARS

SHALL BE COPPER. CABINETS SHALL BE MADE OF CODE GAUGE GALVANIZED SHEET

STEEL, WITH A MINIMUM OF 4 INCH GUTTERS, DOOR IN DOOR CONSTRUCTION,

LOCKED DOOR, AND FLUSH HINGES. TYPEWRITTEN INDEX SHALL BE MOUNTED ON

DOOR INSIDE TRANSPARENT COVER INDICATING LOAD SERVED. PANELS SHALL

INCLUDE SEPARATE EQUIPMENT GROUND BUS.

20. CONDUIT RUNS AS SHOWN ON THE PLANS ARE DIAGRAMMATIC ONLY; EXACT

LOCATION AND METHOD OF SUPPORT SHALL BE DETERMINED IN THE FIELD.

21. CONTRACTOR SHALL CHECK EXISTING CONDITIONS TO DETERMINE EXACT EXTENT

OF WORK TO BE PERFORMED PRIOR TO BIDDING. DIMENSIONS RELEVANT TO

EXISTING WORK SHALL BE VERIFIED IN THE FIELD.

22. PROVIDE AS-BUILT "CADD" DRAWINGS AT THE COMPLETION OF THE PROJECT.

23. ALL EXCAVATION AND BACKFILL SHALL BE BY THE ELECTRICAL CONTRACTOR.

GENERAL ELECTRICAL NOTES :

HANDHOLE SEE DETAIL ON E1.3 THIS DRAWING

-HOMERUN TO PANELBOARD, NUMBER OF SLASH MARKS INDICATES NUMBER OF #12 AWG CONDUCTORS INMINIMUM 3/4" CONDUIT. NO SLASH MARKS INDICATE 2#12 & 1#12G, 3/4"C UNLESS NOTED OTHERWISE. -GREENGROUND CONDUCTOR IS NOT INDICATED BUT SHALL BE INCLUDED IN EACH RACEWAY. SIZE SHALL BE #12UNLESS INDICATED OTHERWISE. -HOMERUNS TO PANELBOARDS SHALL HAVE A MAXIMUM OF THREE PHASECONDUCTORS (ONE PER PHASE) PLUS NEUTRAL AND GROUND CONDUCTOR IN EACH CONDUIT.

ABBREVIATIONS

DEMOLITION NOTES:

1. THE ELECTRICAL CONTRACTOR WILL DEMOLISH THE EXISTING

ELECTRICAL SYSTEMS ASSOCIATED WITH ALL EXISTING

EQUIPMENT TO BE REMOVED. THE ELECTRICAL CONTRACTOR IS

TO DEACTIVATE, DISCONNECT AND REMOVE THOSE SYSTEMS

WHICH WILL BE DEMOLISHED. THE ELECTRICAL CONTRACTOR

WILL REMOVE AND DISPOSE OF ALL ELECTRICAL SYSTEM

MATERIALS INCLUDING DEVICES, FIXTURES, RACEWAYS, CABLE

AND APPURTENANCES.

2. MAKE ANY NECESSARY RE-CIRCUITING, EXTENSIONS OF EXISTING

CIRCUITS AND RELOCATIONS REQUIRED TO PROPERLY RE-ENERGIZE

REMAINING EXISTING SERVICES OR EQUIPMENT THAT MAY BE

INTERFERED WITH BY NEW CONSTRUCTION, REMOVALS OR

RELOCATIONS. ALL SHUT DOWNS TO RELOCATE ACTIVE FEEDERS

OR BRANCH CIRCUITS WILL BE PERFORMED ON HOURS MUTUALLY

AGREED TO WITH THE OWNER.

3. PRIOR TO REMOVAL OF EQUIPMENT, CONFIRM THAT FEEDER AND

BRANCH CIRCUITS ARE NO LONGER ACTIVE. SHOULD IT BE

DISCOVERED THE FEEDER OR BRANCH CIRCUITS ARE ACTIVE,

NOTIFY THE ENGINEER IMMEDIATELY FOR DIRECTION.

4. EXISTING ABANDONED HIGH AND LOW TENSION SYSTEMS ARE TO BE

REMOVED. UNDER NO CIRCUMSTANCES ARE ABANDONED HIGH AND

LOW TENSION SYSTEMS OR SYSTEM COMPONENTS TO REMAIN.

GFI

2"C., 4#2/0 & 1#6GND

XM

XR

XM

TVSS

WP

A

4

XM

4

LOCKABLE FUSEDDISCONNECTSWITCH

6

4

20

20

08/09/2017Date:

BURLINGTON

COMMONS

CENTER STREET

BURLINGTON, MA 01803

Drawn By:

Reviewed By:

Approved By:

Drawing Title:

Sheet Number:

Seal:

Revisions:

No. Date Description

Project:

TOWN OF BURLINGTON, MA

Consultants:

W&S Project No:2170150

COPYRIGHT 2017 WESTON & SAMPSON

Scale:

978.532.1900

www.westonandsampson.com

800.SAMPSON

Issued For:

Weston & Sampson Engineers, Inc.

Five Centennial Drive,

Peabody, MA 01960

ELECTRICAL

LEGEND,

ABBREVIATIONS

AND GENERAL

NOTES

E1.00

NONE

DNM

RFM

RFM

EXISTING ELECTRICAL

CABINET (SEE PHOTO #3)

EXISTING ELECTRICAL

SERVICE DROP TO BE

REMOVED (SEE PHOTO #1)

EXISTING ELECTRICAL

SERVICE TO BE REMOVED

(SEE PHOTO #2)

EXISTING ELECTRICAL

CABINET TO BE REMOVED

(SEE PHOTO #2)

EXISTING ELECTRICAL

CABINET TO REMAIN

EXISTING FLOOD

LIGHT

XM

XR

XM

XM

XM

XM

XM

XM

XR

XM

XM

XM

XM

XR

XR

XM

XM

XM

XM

XM

XM

XM

XR

XR

XR

XR

XR

XR

XR

XR

XR

XR

XR

XR

XR

XM

XM

XR

EXISTING POLE LIGHT

FIXTURE TO REMAIN AND BE

REWIRED. (SEE NOTE #2)

(TYPICAL)

EXISTING

FLOOD LIGHT

XM

XM

EXISTING

SPOT LIGHTS

EXISTING

TRAFFIC

CABINET

XM

XM

EXISTING ELECTRICAL

CABINET TO REMAIN

EXISTING IN-GROUND

LIGHT FIXTURE

EXISTING IN-GROUND

LIGHT FIXTURE

EXISTING IN-GROUND

LIGHT FIXTURE

EXISTING UNDERGROUND

ELECTRIC SERVICE TO BE

REMOVED (SEE PHOTO #3)

XR

EXISTING UNDERGROUND

ELECTRIC SERVICE

FEEDING PANELS UNDER

BANDSTAND TO BE

REMOVED (SEE PHOTO #1)

T

EXISTING UTILITY COMPANY

POLE MOUNTED TRANSFORMER

T

EXISTING UTILITY COMPANY

POLE MOUNTED TRANSFORMER

EXISTING GAZEBO

XM

XM

XM

EXISTING TREE MOUNTED

RECEPTACLE TO BE REMOVED

(TYPICAL)

EXISTING LIGHT POLE

FIXTURE WITH BASE

MOUNTED RECEPTACLE TO

BE REWIRED. SEE NOTE #1

(TYPICAL)

EXISTING PANEL BOARD MOUNTED UNDER GAZEBO TO

REMAIN AND BE RE-FED FROM NEW SERVICE, SEE

DRAWING E1.02. ALL EXISTING POWER AND

COMMUNICATIONS EQUIPMENT UNDER GAZEBO SHALL

REMAIN.

08/09/2017Date:

BURLINGTON

COMMONS

CENTER STREET

BURLINGTON, MA 01803

Drawn By:

Reviewed By:

Approved By:

Drawing Title:

Sheet Number:

Seal:

Revisions:

No. Date Description

Project:

TOWN OF BURLINGTON, MA

Consultants:

W&S Project No:2170150

COPYRIGHT 2017 WESTON & SAMPSON

Scale:

978.532.1900

www.westonandsampson.com

800.SAMPSON

Issued For:

Weston & Sampson Engineers, Inc.

Five Centennial Drive,

Peabody, MA 01960

ELECTRICAL SITE

DEMOLITION PLAN

E1.01

1" = 40' - 0"

DNM

RFM

RFM

ELECTRICAL DEMOLITION SITE PLAN

PHOTO NO.2

PHOTO NO.2

PHOTO NO.3

PHOTO NO.1

NOTES:

1. TYPICAL FOR ALL EXISTING LIGHT POLES WITH BASE

MOUNTED RECEPTACLES. EXISTING LIGHT POLE REMAIN

AND BE REWIRED TO NEW CIRCUIT VIA A NEW HAND HOLE.

EXISTING LIGHT POLE BASE MOUNTED RECEPTACLE TO BE

REPLACED AND REWIRED TO NEW CIRCUIT.

2. TYPICAL FOR ALL EXISTING LIGHT POLES AND GROUND

MOUNTED SPOT, FLOOD AND ACCENT LIGHTING EXISTING

FIXTURES ARE TO BE REWIRED TO NEW CIRCUIT.

3. TO THE EXTENT POSSIBLE EXISTING CONDUIT NO LONGER

IS USE SHALL BE REMOVED. ALL EXISTING WIRING IS TO BE

REMOVED.

NEW ELECTRICAL

CABINET

GFI

WP

GFI

WP

GFI

WP

GFI

WP

GFI

WP

GFI

WP

GFI

WP

GFI

WP

GFI

WP

GFI

WP

GFI

WP

GFI

WP

GFI

WP

GFI

WP

GFI

WP

XM

XM

XM

XM

XM

XM

XM

XM

XM

XMXM

XM

XM

XM

XM

XM

XM

XM

HANDHOLE (TYPICAL)

(SEE NOTE #2)

EXISTING UTILITY RISER POLE

WITH NEW POLE MOUNTED

TRANSFORMERS

C1,C4,C16

2

3

2

2

2

2

9

C1,C4

C1,C4,C16

C4

C1,C16

C1

C1

2" DIRECT BURIED

CONDUIT FOR

SECONDARY POWER

C2,C5,C6

C2,C5,C6

4

5

5

5

5

5

4

4

4

4

4

7

7

7

C6

C2

C2,C5

C2,C6

C6

C6

C5

C6

C6

C2,C5

C5

C1,C4,C16

C4

3

3

3

11

6

6

6

6

6

6

6

6

12

8

12

8

12

10

10

C3

C3,C7,C8,C14

C3,C7,C8

C3,C7,C8,C14

C8

C3,C8

C14

C14

C3,C7,C14

C3,C7

C3,C8

C8

C8

XM

6

C3

4

C2

EXISTING FLOOD

LIGHT

EXISTING

FLOOD

LIGHT

XM

XM

EXISTING

SPOT LIGHT

C1

C3,C11

C3

XM

XM

XM

EXISTING IN-GROUND

LIGHT FIXTURE

EXISTING IN-GROUND

LIGHT FIXTURE

EXISTING

IN-GROUND

LIGHT FIXTURE

NEW POLE MOUNTED

LIGHT FIXTURE OMNI

LIGHT 6130 LED

HERITAGE SERIES

C1,C4

C3,C7,C8,C14

C3,C7,C8,C14

SPEAKER

SPEAKER

GFI

WP

9

C10

GFI

WP

9

C10,C15

C4

SPEAKER

SPEAKER

GFI

WP

8

GFI

WP

8

C7

C7

C9 (SEE NOTE #1)

7

C10,

C15

6

6

6

GFI

WP

8

C12

C12

A

C12

C12

C7

NEW POST MOUNTED

DUPLEX RECEPTACLE

SEE DETAIL 7/E1.03.

(TYPICAL)

GFI

WP

7

GFI

WP

13

GFI

WP

13

GFI

WP

13

GFI

WP

13

GFI

WP

13

C13

C13

C13

C13

C13

C13

GFI

WP

14 1618

C15

GFI

WP

GFI

WP

3

GFI

WP

C4

C16

TERMINATE CONDUCTORS IN

HANDHOLE FOR FUTURE

CONNECTION TO ELECTRONIC SIGN

GFI

WP

8

GFI

WP

7

C6

08/09/2017Date:

BURLINGTON

COMMONS

CENTER STREET

BURLINGTON, MA 01803

Drawn By:

Reviewed By:

Approved By:

Drawing Title:

Sheet Number:

Seal:

Revisions:

No. Date Description

Project:

TOWN OF BURLINGTON, MA

Consultants:

W&S Project No:2170150

COPYRIGHT 2017 WESTON & SAMPSON

Scale:

978.532.1900

www.westonandsampson.com

800.SAMPSON

Issued For:

Weston & Sampson Engineers, Inc.

Five Centennial Drive,

Peabody, MA 01960

ELECTRICAL SITE

NEW WORK PLAN

E1.02

1" = 40' - 0"

DNM

RFM

RFM

ELECTRICAL NEW WORK SITE PLAN

C1SITE LIGHTING1"C., 2#10 & 1#10GND PPH1-2

CONDUIT & WIRING SCHEDULE

CONDUIT

TAG

FEEDER

REMARKS

TOFROM

C2SITE LIGHTING

DIRECT BURIED,VIA

TIMECLOCK CONTROLLED

CONTACTOR

1"C., 2#10 & 1#10GND PPH1-4

C3SITE LIGHTING1"C., 2#10 & 1#10GND PPH1-6

C4SITE RECEPTACLES DIRECT BURIED1"C., 2#10 & 1#10GND

PPH1-3

C5SITE RECEPTACLES DIRECT BURIED1"C., 2#10 & 1#10GND PPH1-5

C6SITE RECEPTACLES DIRECT BURIED1"C., 2#10 & 1#10GND

PPH1-7

C7

C8

SITE RECEPTACLES DIRECT BURIED1"C., 2#10 & 1#10GND PPH1-8

SITE RECEPTACLES DIRECT BURIED1"C., 2#10 & 1#10GND PPH1-10

C9

EXISTING GAZEBO

PANEL

DIRECT BURIED

SEE NOTE 1

2"C., 4#2/0 & 1#6GNDPPH1-27,29

C10SITE RECEPTACLES DIRECT BURIED1"C., 2#10 & 1#10GND PPH1-9

C11SITE RECEPTACLES

DIRECT BURIED, SEE

SPEAKER NOTES BELOW

1"C., 2#10 & 1#10GNDPPH1-11

C12SPEAKER WIRING DIRECT BURIED1"C. N/A

NOTES:

1. ELECTRICAL CONTRACTOR SHALL RUN NEW CONDUITS UNDERGROUND TO

RE-FEED EXISTING POWER PANEL LOCATED UNDER GAZEBO.

2. FOR EACH EXISTING TO REMAIN SITE PEDESTRIAN LIGHT POLE CONTRACTOR

SHALL PROVIDE A NEW HAND HOLE FROM WHICH NEW POWER FEED TO

EXISTING POLE ENTRANCE AND IF PRESENT EXISTING REPLACED BASE

MOUNTED RECEPTACLE.

SPEAKER NOTES:

1. FROM EACH SPEAKER JACK LOCATION (4 TOTAL) ELECTRICAL CONTRACTOR

SHALL RUN A 1" PVC CONDUIT FROM THE SPEAKER LOCATION TO THE GAZEBO

AND TERMINATE IN A DOUBLE GANG BOX.

2. AT EACH SPEAKER JACK LOCATION. ELECTRICAL CONTRACTOR SHALL FURNISH

AND INSTALL A SINGLE GANG WATERPROOF BOX. (SEE DETAIL 7/E1.03)

DIRECT BURIED,VIA

TIMECLOCK CONTROLLED

CONTACTOR

DIRECT BURIED,VIA

TIMECLOCK CONTROLLED

CONTACTOR

C13SITE RECEPTACLES DIRECT BURIED1"C., 2#10 & 1#10GND PPH1-13

C14SITE RECEPTACLES DIRECT BURIED1"C., 2#10 & 1#10GND PPH1-15

C15SITE RECEPTACLES DIRECT BURIED1"C., 2#10 & 1#10GND PPH1-18,20,22

C16FUTURE SIGN DIRECT BURIED1"C., 2#10 & 1#10GND

PPH1-17

3'-0

"

PLAN

1'-6

"

ELEVATION

CONDUIT

NEW ELECTRIC METERMOUNTED TOENCLOSURE

FINISHEDGRADE

3'-0"

3'-0"

EMBEDDED LEVELINGCHANNELS

2-1/2" ANCHOR BOLTS16" ON CENTER

6"2'

-0"

COPPER GROUND ROD3/4"x10' LONG

#5 BARS @ 12" CENTERS

1/4" x 1 1/2" STRAPWELDED TO CHANNEL2'-0" OC

3" MINIMUMCOVER OVERREBAR

NOTE: FINAL CABINET SIZE SHALL BE DETERMINED BASED ON ACTUALEQUIPMENT AND LAYOUT OF EQUIPMENT

PAD MOUNTED ELECTRICAL ENCLOSURE NO SCALE

4

FINISHED GRADE

ANCHOR BOLTS WITH LEVELING

NUTS BY POLE MFR

SELECT COMMON FILL

COMPACTED IN 12" LIFTS

#4 HOOPS AT 12" ON CENTER

8-#5 EQUALLY SPACED

CONCRETE BASE

DIM

"A

"

SE

E T

AB

LE

B

EL

OW

30"

6"

24" DIA

UNDISTURBED

EARTH

POLE HEIGHT

10'-0"

20'-0"

DIMENSION "A"

4'-6"

4'-6"

BOND CIRCUIT GROUND-

ING CONDUCTOR TO POLE

INSULATED GROUNDING

BUSHINGS BONDED

TO POLE (TYPICAL)

POLE WITH HANDHOLE AND

INTERNAL GROUNDING STUD

2" CHAMFER

GROUT

CONDUIT SEE SITE PLAN (TYP)

TYPICAL NEW LIGHT POLE BASE DETAIL NO SCALE3

NOTE:

18"

6"

1'-4"

8" 8"

C TRENCH& CONDUIT

LFINISH GRADE

COMPACTED SUITABLE BACKFILL- BY GENERAL CONTRACTOR

COMPACTED SUBGRADE OR SUITABLEBACKFILL - ALL EXCAVATION ANDBACKFILL SHALL BE BY THEELECTRICAL CONTRACTOR

SCHEDULE 40 PVCCONDUIT, SIZED ASNOTED ON THE PLAN

12"

TYPICAL DIRECT BURIED CONDUIT DETAIL NO SCALE1

PLASTIC CAUTION TAPE -BY GENERAL CONTRACTOR

EXISTING PRIMARY RISER POLE

48" RADIUS x 90° GALVANIZED STEELSWEEP. SPARE SWEEP MUST HAVE ATHREADED CAP AND GROUNDBUSHING JUST ABOVE GRADE. (2) 4"CONDUITS

PVC TO STEEL CONDUITADAPTER

3/4" DIA. x 10'-0" COPPER CLADGROUND ROD

BOND TO GROUND

SPARE (1) 2" CONDUIT (CAPPED)

1" PVC CONDUIT 10'-0" MINIMUMABOVE GRADE

CONCRETE DUCTBANK TO NEWMANHOLES

RGS SERVICE CONDUIT, TERMINATE10'-0" ABOVE FINISH GRADE MIN.

RGS CONDUITCLIP 4'-0" O.C.MIN.

10'-0" ABOVEFIN. GRADE

No. 4 AWG BARE COPPER WIRE

INSULATED GROUND BUSHING

BOND TO GROUND

TYPICAL RISER POLE DETAIL NO SCALE5

17.5"

NOTES:

1. THIS HANDHOLE IS INTENDED FOR NON-DELIBERATE VEHICULAR TRAFFIC ONLY.

2. HANDHOLE SHALL BE PREFABRICATED POLYMER CONCRETE AGGREGATE EQUAL TO QUAZITE OR EQUAL PRE CASTCONCRETE CONSTRUCTION OR APPROVED EQUAL

18.5"

11.5" 13.5"

38" STAINLESS

STEEL BOLTS W/WASHERS(TYPICAL FOR 4)

NON METALLIC SKIDRESISTANT SURFACE

6" MIN

OPENBOTTOM

CRUSHEDSTONE BASE 6"

MIN6"

MIN

18.5"

12" MIN.

TYPICAL PREFABRICATED HANDHOLE DETAIL NO SCALE6

LOAM AND SEED

CONCRETE

18"

6"X6" PRESSURE

TREATED POST

PAINTED WHITE

24"

6"

DECORATIVE CAP (TO BE

APPROVED BY TOWN) PAINTED

WHITE

42" P

OS

T H

EIG

HT

30" T

O B

OT

TO

M O

F

RE

CE

PT

AC

LE

DUPLEX RECEPTACLE GFCI

WITH WEATHERPROOF,

LOCKABLE IN-USE COVER

CONDUIT

18"

POST AND RECEPTACLE DETAIL NO SCALE7

POST AND RECEPTACLE DETAIL NO SCALE8

NEW HANDHOLE

1"C. QUANTITY AND WIRING AS

INDICATED ON DRAWING E1.02

GFI

WP

1"C. WITH WIRING TO FEED

LIGHT AS INDICATED ON PLANS.

1"C. WITH WIRING TO FEED

WHERE PRESENT

RECEPTACLE

EXISTING LIGHT POLE

ALL EXCAVATION, BACKFILL & CONCRETE SHALL BE BY THE

ELECTRICAL CONTRACTOR.

LOCKABLE FUSEDDISCONNECTSWITCH

TYPICAL FOR 4 LOCATIONS

ONLY PROVIDE SINGLE GANG

WATERPROOF BOX TO HOUSE

THE XLR CABLE AND SPEAKER

JACK.

USE 1 1/2" CRUSHEDSTONE BEDDING IF

WATER ISENCOUNTERED

08/09/2017Date:

BURLINGTON

COMMONS

CENTER STREET

BURLINGTON, MA 01803

Drawn By:

Reviewed By:

Approved By:

Drawing Title:

Sheet Number:

Seal:

Revisions:

No. Date Description

Project:

TOWN OF BURLINGTON, MA

Consultants:

W&S Project No:2170150

COPYRIGHT 2017 WESTON & SAMPSON

Scale:

978.532.1900

www.westonandsampson.com

800.SAMPSON

Issued For:

Weston & Sampson Engineers, Inc.

Five Centennial Drive,

Peabody, MA 01960

ELECTRICAL

DETAILS

E1.03

NONE

DNM

RFM

RFM


Recommended