6
MJK North America, Inc. 37 Sherwood Terrace, #126 Lake Bluff, IL 60044 Tel: 847-482-8655 877 MJK LINK Fax: 847-482-8654 [email protected] www.mjk.com Data Sheet As our products are continuously improved, we reserve the right to make any change in the stated specifications and dimensions without prior notice. US 3.8 Flumes 0608 3.8 Prefabricated Palmer-Bowlus and Parshall Flumes Maintenance free, accurate and economical.
Transcript
Page 1: Prefabricated Palmer-Bowlus and Parshall Flumespt.mjk.com/fileadmin/downloadcenter/3._Flow_meters/... · General The Parshall flumes are made of fiberglass-reinforced polyester resins

MJK North America, Inc.37 Sherwood Terrace, #126Lake Bluff, IL 60044Tel: 847-482-8655 877 MJK LINKFax: [email protected]

Data Sheet

� Asourproductsarecontinuouslyimproved,wereservetheright tomakeanychangeinthestatedspecificationsanddimensionswithoutpriornotice.US3.8Flumes0608

3.8

Prefabricated Palmer-Bowlus and Parshall Flumes

Maintenance free, accurate and economical.

Page 2: Prefabricated Palmer-Bowlus and Parshall Flumespt.mjk.com/fileadmin/downloadcenter/3._Flow_meters/... · General The Parshall flumes are made of fiberglass-reinforced polyester resins

MJK North America, Inc.37 Sherwood Terrace, #126Lake Bluff, IL 60044Tel: 847-482-8655 877 MJK LINKFax: [email protected]

Data Sheet

Palmer-Bowlus Flumes

General ThePalmer-Bowlustrapezoidalthroatdesignensuresahighvelocityatcriticalflowlevels,translatingintominimalflowrestric-tion,lowenergylossandbettermeasure-mentaccuraciesatbothlowflowandpeakcapacity.Thesmoothgelcoatedsurfacesminimizefrictionandpreventsolidsbuild-up.Aone-piecemoldedconstructionmakesinstallationquick,easyandcosteffective.Allcomponentsaremadewithcorrosionresistantmaterialsforwiderangesofap-plicationtypes.ManufacturedtoconformtoASTMandUSDepartmentoftheInteriorstandards.

Specifications

Dimensions

Size: CFS: MGD: GPM: Max.head: Shippingweight: ThroatSize

Approximately @approx. Permanent Insert Exit/cutback

maximumdischarge max.discharge

4” 0.�� 0.07 54 3.0” �0lbs 7lbs 5lbs 6” 0.30 0.�9 �3� 4.�” �5lbs �0lbs 8lbs 8” 0.69 0.45 3�0 6.0” �0lbs �5lbs ��lbs �0” �.�� 0.7� 50� 7.�” �5lbs �0lbs �7lbs ��” �.67 �.08 75� 8.4” 33lbs �5lbs �0lbs �5” 3.09 �.99 �,385 �0.8” 50lbs 33lbs 30lbs �8” 4.6� �.98 �,07� ��.6” 75lbs 50lbs 45lbs ��” 7.04 4.55 3,�6� �5.0” ��5lbs 75lbs 65lbs �4” 9.47 6.�0 4,�48 �6.8” �50lbs 90lbs 80lbs �7” �3.09 8.44 5,873 �9.�” - ��0lbs �00lbs 30” �6.5� �0.66 7,4�3 ��.0” - �30lbs ��5lbs 36” �9.97 �9.37 �3,45� �7.0” - �75lbs �60lbs 4�” 43.77 �8.�9 �9,645 3�.4” - �00lbs �85lbs

Permanent Exit/cutback Insert

D: D/2: L1: L2: H: R: Y: C: T:

4” �” �7” �0” 6” �/3” ��3/�6” 45/8” 3/�6”

6” 3” �5” �4” 8” �” ��3/�6” 65/8” 3/�6”

8” 4” 33” �8” �0” ��/3” 3�3/�6” 85/8” 3/�6”

�0” 5” 4�” ��” ��” ��/3” 4�3/�6” �05/8” 3/�6”

��” 6” 49” �6” �4” �” 5�3/�6” ��5/8” 3/�6”

�5” 7�/�” 6�” 3�” �7” ��/�” 75/�6” �55/8” 3/�6”

�8” 9” 73” 38” �0” 3” 8�3/�6” �85/8” 3/�6”

��” �0�/�” 85” 44” �3” 3�/�” �05/�6” ��5/8” 3/�6”

�4” ��” 97” 50” �6” 4” ���3/�6” �45/8” 3/�6”

�7” �3�/�” �09” 56” �9” 4�/�” �35/�6” �75/8” 3/�6”

30” �5” ���” 6�” 3�” 5” �4�3/�6” 305/8” 3/�6”

36” �8” �45” 74” 38” 6” �7�3/�6” 365/8” 3/�6”

4�” ��” �69” 86” 44” 7” �0�3/�6” 4�5/8” 3/�6”

Flow directionFlow direction

Flow direction

Page 3: Prefabricated Palmer-Bowlus and Parshall Flumespt.mjk.com/fileadmin/downloadcenter/3._Flow_meters/... · General The Parshall flumes are made of fiberglass-reinforced polyester resins

MJK North America, Inc.37 Sherwood Terrace, #126Lake Bluff, IL 60044Tel: 847-482-8655 877 MJK LINKFax: [email protected]

Data Sheet

3

Parshall Flumes

Size: CFS: MGD: GPM: Max.head: Shippingweight:Dimension“D”

Approximately @approx. maximumdischarge max.discharge

�” 0.36 0.�3 �6� 8” 35lbs 3” �.86 �.�0 834 �8” 45lbs 6” 3.9� �.5� �,754 �8” 65lbs 9” 8.87 5.73 3,980 �4” 85lbs ��” �6.�3 �0.40 7,��5 30” �75lbs �8” �4.60 �5.89 ��,040 30” �85lbs �4” 33.�� ��.39 �4,855 30” �40lbs 36” 50.39 3�.57 ��,6�9 30” 3�0lbs 48” 67.93 43.88 30,473 30” 4�0lbs

General TheParshallflumesaremadeoffiberglass-reinforcedpolyesterresinslayedupoverwhiteisophthallicgel-coat.Theyhavearigid�-piececonstructionandareespeciallywellsuitedformeasuringliquidscontainingso-lids.ManufacturedtoconformtoASTMandUSDepartmentoftheInteriorstandards.Thesmoothsurfaceandinternalflowlineshelpreducemeasuringerrorsthatoccurewiththeaccumulationofdebris.TheintegralreinforcingribsandextrudedFRPangles,boltedtothetopflanges,aidinmaintainingdimensionalintegrityduringshipmentandinstallation.Fiberglassanchorclipsareprovidedtohelpsecuretheunitinconcrete.

Specifications

W: A: 2/3A: B: C: D: E: F: P: K: N: R: T:

�” �’-45/�6” �07/8” �’-4” 55/�6” 8�3/3�” 9” 4�/�” �’-6�/�” 7/8” ���/�6” �3/4” 3/�6”

3” �’-63/8” �’-�/4” �’-6” 7” �03/�6” �’-0” 6” 3’-0” �” ��/4” �” 3/�6” 6” �’-7/�6” �’-45/�6” �’-0” �’-3�/�” �’-35/8” �’-0” �’-0” 5’-0” 3“ 4�/�” ��/�” 3/�6” 9” �’-�05/8” �’-���/8” �’-�0” �’-3” �’-�05/8” �’-6” �’-0” 5’-4” 3“ 4�/�” ��/�” 3/�6” ��” 4’-6” 3’-0” 4’-47/8” �’-0” �’-9�/4” 3’-0” �‘-0“ 9’-47/8” 3” 9“ ��/�” �/4” �8” 4’-9” 3’-�” 4’-77/8” �’-6” 3’-43/8” 3’-0” �‘-0“ 9’-77/8” 3” 9“ ��/�” �/4” �4” 5’-0” 3’-4” 4’-�07/8” 3’-0” 3’-���/�” 3’-0” �‘-0“ 9’-�07/8” 3” 9“ ��/�” �/4” 36” 5’-6” 3’-8” 5’-43/4” 4’-0” 5’-�7/8” 3’-0” �‘-0“ �0’-43/4” 3” 9“ ��/�” 5/�6” 48” 6’-0” 4‘-0” 5’-�05/8” 5’-0” 6’-4�/4” 3’-0” �‘-0“ �0’-45/8” 3” 9“ ��/�” 3/8”

Dimensions

Flow direction

Can be delivered with optional stilling well on either left or right hand side. Contact MJK for further

information.

Page 4: Prefabricated Palmer-Bowlus and Parshall Flumespt.mjk.com/fileadmin/downloadcenter/3._Flow_meters/... · General The Parshall flumes are made of fiberglass-reinforced polyester resins

MJK North America, Inc.37 Sherwood Terrace, #126Lake Bluff, IL 60044Tel: 847-482-8655 877 MJK LINKFax: [email protected]

Data Sheet

4

Palmer-Bowlus and Parshall Flumes

Palmer-Bowlusprefabricatedflumes: Parshallprefabricatedflumes:Dimension: Permanent: Insert: Exit/cutback: Standardincludesstaffgauge:

�” - - - �79000 3” - - - �7900� 4” �79�00 �79�00 �79300 - 6” �79�0� �79�0� �7930� �7900� 8” �79�0� �79�0� �7930� - 9” - - - �79003 �0” �79�03 �79�03 �79303 - ��” �79�04 �79�04 �79304 �79004 �5” �79�05 �79�05 �79305 - �8” �79�06 �79�06 �79306 �79005 ��” �79�07 �79�07 �79307 - �4” �79�08 �79�08 �79308 �79006 �7” - �79�09 �79309 - 30” - �79��0 �793�0 - 36” - �79��� �793�� - 4�” - �79��� �793�� -

Order numbers

Options(Consult MJK)

•Embeddedstaffgaugewithcalibrationunitsin0.�’,0.0�’&¼”increments.

•Attachedstillingwellsin��”,�0”,8”,and6”I.D.canbesupplied.

•Shuttle®UltrasonicLevelMeterwithsup-portbracketforShuttle®LevelTransmitter.Seeseparatedatasheet.

•�½”widestandardendflangesinfiberglass.

•Bulkheadsandpipestubscanbebuiltonformanyapplications.

•AdditionalflumestylessuchasHandtrape-zoidalcanbebuilttospecifications.

•Allflumesarebuilttoorder-pleaseallow3weeksfordelivery.

Universalbracket(200205)

Standardsensorbracket(200220)

Shortsensorbracket(200219)

Sensorbracketforchannelorflume(��.6in:200230/37.4in:200235)

��.6/37.4in

4.5in

�in

�9.7in

Mounting Brackets

Page 5: Prefabricated Palmer-Bowlus and Parshall Flumespt.mjk.com/fileadmin/downloadcenter/3._Flow_meters/... · General The Parshall flumes are made of fiberglass-reinforced polyester resins

MJK North America, Inc.37 Sherwood Terrace, #126Lake Bluff, IL 60044Tel: 847-482-8655 877 MJK LINKFax: [email protected]

Data Sheet

5

Palmer-Bowlus and Parshall Flumes

TheMJK7�3worksbymeasuringflowinflumesorweirs.TheMJK7�3measuresthedepthofflowintheflumeorweirandcalculatestheflowratebasedonthestan-dardcurvefortheflumeorweirused.Thisistypicallybasedontheequation:

FLOW Q = level x * constant

Theexponent(X)andconstantdependonthetypeofprimarydeviceused.Apre-programmedlistofstandardweirs

How the MJK 713 Open Channel Flowmeter works

andflumesallowseasyselectionoftheequationrequiredfortheflumeorweir,howeveracustomcurvecanbeconfiguredfornon-standardflumesorweirs.

TheMJK7�3iseasilyoperatedwith4functionkeys:FlowKey,TotalizerKey,AlarmKey,andtheSamplerKey.Thefunctionkeysallowsaccesstothevariousparametersshownbelow:

Flow key: •actualflowrate•averageflowrate - overlasthour - today - previousday

Totalizer key:• totalflow - sincestartup - overlasthour - today - previousday - anypreviousdayup

to99daysback

Alarm key:•displayslast9alarmswith

dateandtimestamp - sensorerrors - highandlowflowalarms - highandlowhourlyflows - highandlowflowforday - powerfailure

Sampler key:• totalsamples• totalsamplestoday• totalsamplespreviousday

Page 6: Prefabricated Palmer-Bowlus and Parshall Flumespt.mjk.com/fileadmin/downloadcenter/3._Flow_meters/... · General The Parshall flumes are made of fiberglass-reinforced polyester resins

Denmark [email protected]+4545560656

The [email protected]+3��5�67��7�

North America [email protected]+�84748�8655

[email protected]+4769�06070

[email protected]+46533�7750

[email protected]+6�397588533

Dis

trib

uted

by:

MJK

offi

ces:

Data Sheet Palmer-Bowlus and Parshall Flumes

Formeasurementaccuracyuseflumesizestomatchactualflows.Sizingtonominalpipesizeisnotalwayscorrect.Optimumflowreadingsareob-tainedbyselectingaflumesizethathasflowratesbetweenmaximumandminimumdischargerates.

Typicallyoversizedflumesreducetheac-curacyoftheflowmeasurement.Whenthepipelinesizeislargerthantheflume,theapproachsection,constructedonsitebytheinstaller,onthepermanentflumemustsmooththeflowbeforeitreachesthepointofmeasurement.

GeneralFlumesshouldnotbeplacedatrightanglestoflowingstreamssuchasinturnoutsun-lesstheflowiseffectivelystraightenedanduniformlyredistributedbeforeitenterstheflume.Surgesandwavesofanyappreciablesizeshouldbeeliminatedandtheflowlinesshouldbeessentiallyparalleltotheflume’scenterline.Also,theflowattheflume’sen-tranceshouldbefreeofturbulence(visiblesurfaceboils).

AllflumeshaveextrudedFRPanglesthatareboltedontothetopflangestomaintaindimensionalintegrityduringshipmentandinstallation.AlthoughtheseanglescanberemovedAFTERtheinstallationprocessiscomplete,MJKrecommendsleavingtheanglesinplacetomaintaintheflume’sdimensionalintegrityshouldthegroutsink.

Palmer-Bowlus flumes grouted in placePermanenttypePalmer-Bowlusflumesaretypicallygroutedintoplacebetweentwosectionsofpipehavingthesamediameterastheflume.Inexistingpipelines,asectionofpipeequaltothelengthoftheflumeisremovedandreplacedwiththeflume.

Wheninstalingtheflume,theinvert(insidebottommostpoint)shouldbeusedasareference.Theinvertoftheflumemustbelevelinbothfronttobackandsidetosidedirections.Theparallelsidewallsmustbeplumb.Theflumeshouldbesetonasolidfoundationtopreventsettlingorheaving.FRPanchorclipsareprovidedforattachingwiretotheflumetopreventtheflumefromfloatingorshiftingduringstagedpouringofflowablegrout.

Internalbracingmustbeprovidedontheperpendicularsidewallsoftheflumebytheinstallertopreventanyunduestressordeformationduringbackfillingwithflowablegroutorothermaterials.Flowablegroutbackfillshouldbestagefilledpouredin�to6”deepincrements(lifts)withminimaluseofavibrator.ThefirstliftshouldbeSLOWLYpouredononesidesothatthegroutwillflowundertheflumetotheotherside,therebyhelpingtoeliminateanyvoidareasundertheraisedtrapezoidalfloorsection.Eachliftmustbeallowedtosetupbeforenextstageispoured.

Parshall flumes grouted in placeWheninstallingParshallflumes,thecrest(flooroftheconvergingsection)shouldbeusedasareference.

Thecrestoftheflumemustbelevelinbothfronttobackandsidetosidedirections.

Flumesshouldbesetonasolidfoundationtopreventsettlingorheaving.FRPanchorclipsareprovidedforattachingwirestotheflume.Thisaidsinpreventingtheflumefromfloatingorshiftingduringstagepouringofflowablegrout.

Wheninstallingflumes,internalbracingshouldbeprovidedbytheinstaller.

Thishelpstopreventanyunduestressordeformationduringbackfillingwithflowablegroutorothermaterials.Flowablegroutbackfillshouldbe“stage-poured”inappro-ximately6”deepincrements(“lifts”).Thefirst6”“lift”shouldbepouredSLOWLYononeside,Thisallowsthegrouttoflowundertheflumetotheoppositeside,bythathelpingtoeliminateanyvoidareasunderthefloorsection.Each“lift”mustbeallowedtosetupbeforethenext“lift”ispoured.

Selecting a flume

Installation requirements


Recommended