SCAP DBS System on a R80 platform with Stack 4 X 40 System DBS Patent pending Dried Blood Spot Automated sample extraction platform for online LC-MS/MS bioanalysis
Transcript
  • SCAP DBS System on a R80 platform with Stack 4 X 40

    System DBS

    Patent pending

    Dried Blood Spot

    Automated sampleextraction platformfor online LC-MS/MSbioanalysis

  • DBS Integrated Sample Processing

    Automated sample processing Advantages

    SCAP DBS system components mounted on a robotic platform

    Comparison of conventional DBS sample handling with the SCAP DBS system

    Dried blood spot (DBS) technology coupled to highly sensitive LC-MS/MS systems opens up new ways in bioanalytics both in the healthcare and the pharmaceutical industries. In the healthcare industry, complete measure-ments are done to diagnose patients to determine the efficacy of administered drugs or to screen for early detection of diseases. In the pharmaceutical industry, measurements are done during the development process of new drugs (e.g. PK/TK studies, etc.).

    The major drawback of conventional DBS bio- analytics is the time consuming, error prone and labor intensive nature of manual sample pre-treatment. The SCAP DBS system from Prolab Instruments represents a unique approach for direct and automated DBS analysis and eliminates the drawback of current methods. The SCAP DBS system fully automates the DBS cards handling and allows online sample extraction without the need for punching of sample cards.

    Fully automated DBS system sample card handling for LC/MS-MS analysis

    Optimized extraction of DBS

    Simplified method development by online extraction

    Fully automated process saves time and labour costs

    No need for additional consumables

    Conventional DBS workflow:

    Preparing logistics and consumables for offline DBS sample handling.

    Load DBS card into SCAP DBS system and start automated process

    SCAP DBS systemprocedure

    Punching out DBS cards

    Pipetting of extraction solvent(s) and internal standard

    Extraction / Shaking – Ultra sonic treatment

    Centrifugation / Filtration

    Injection into HPLC - System

    Injection into SCAP HPLC - System

  • Interchangable clamp adapters allow the extraction of variable area sizes from the DBS

    SCAP DBS sample process

    The rack with the DBS cards is placed into the SCAP DBS system. According to the software-defined sample list, the robotic arm transfers the card into the clamp module where the DBS card is directly inserted into the HPLC flow path for online extraction without punching out any part of the DBS card. The different adapters available for the SCAP DBS system allow for extraction of different areas of the sample spot and seal the DBS card against pressures of up to 200 bar.

    The valve system configuration allows the online addition of internal standard (ISTD) during sample extraction. A SPE pre column is used for online sample cleanup prior to analytical separation on the main column.

    Efficient SCAP DBS Workflow

    Multiple spot extractionCamera for image analysis

    SCAP DBS clamp adapters

    Sample card returned to rack

    Picks up sample card from SCAP DBS system rack

    Places card into SCAP DBS system clamp module

    DBS extraction

    Phot clamp adapters

  • Efficient SCAP DBS Workflow

    The robotic gripper tool picks up a sample card... ... and places it into the clamp module where it is inserted into the analytical flow path.

    Dual valve application example

    Column switching configuration with a six and a ten port valve

    Clamp Adapters

    Analytical Pump

    ISTDLoop

    WasteWaste

    DBS Card

    Dilutor ISTD

    to MS

    Analytical Column

    Extraction Pump

    21

    34

    5

    6102

    1

    3

    4

    5 67

    8

    9

    SPE Column Trap

    A BA B

  • Software

    Safety:Automatic detection of proper DBS card, card type, and sample spot

    Precision:Automatic centration of sample spot for extraction targeting

    Repeatability:Distinct offsets from spot center for up to four extractions of the same sample

    Documentation:Complete tracking of samples from card to analytical data:

    Card picture before and after extraction

    Barcode reading (unique card ID and additional customer barcodes)

    Run-time data (timestamps, barcodes, pictures) automatically attached to analytical data, allowing for integrated reports*

    The comprehensive and easy-to-use software package includes:

    Sample list

    Method editor

    Run control and detailed status feedback

    History viewer

    InterfacesExcel™ import and export for sample lists and run-time data

    Analytical system (LC-MS/MS) connected by contact closure or software integration*

    Flexible integration of customer devices

    *depending on analytical data system used

    Camera and Image Analysis

    Offsets first spot extraction

    Allows multiple extractions per spotDetects DBS and centers on the spot

    Software

  • Heinig K, Wirz T, Bucheli F, Gajate-Perez A. Determination of oseltamivir (Tamiflu®) and oseltamivir carboxylate in dried blood spotsusing offline or online extraction. Bioanalysis. 3(4):421-37.

    Ganz N, Singrasa M, Nicolas L, Gutierrez M, Dingeman-se J, Döbelin W,Glinski M. Development and validation of a fully automated online human dried blood spot analysis of bosentan and its metabolites using the Sample Card And Prep DBS System. J Chromatogr B Analyt Technol Biomed Life Sci. 15;885-886:50-60.

    Prolab GmbH acknowledges all tradenames and trademarks used as the property of their respective owners.

    SCAP system® is a registered trademark of Prolab Instruments GmbH, Patent Pending

    Camera Card Stack Gripper Clamp Module Valve Module ISTD Dilutor

    Kägenstrasse 17CH-4153 ReinachSwitzerland

    Tel: +41 61 712 01 28Fax: +41 61 712 01 48Web: www.prolab.che-mail: [email protected]

    SCAP DBS sales contact:

    Literature


Recommended