Capability statement
SureSearch is an industry leader in the utility locating, mapping and asset protection. Established by the Wakelin family in 2000, SureSearch delivered to Sydney the first Pipe, Cable and Leak detection service. It grew through a strong focus on customer and industry requirements, nurturing their employees and being the innovators of the industry. We rely on developing stringent procedures and in-house training to ensure we continue to deliver the industry leading standard that the SureSearch name is renowned for. We provide our clients with accurate information to assist in the design and construction of projects, with minimal risk of injury or delay.
In 2018 SureSearch was acquired by Cardno Ltd, a global infrastructure, environment and social development company operating in more than 100 countries and powered by a talented strong
workforce thus allowing SureSearch to expand and grow under the public company Intega Group Ltd and the Construction Sciences Pty Ltd management team
Our technicians and operators are highly trained. We never use contractors, and all SureSearch operators are employed directly.
SureSearch service all of NSW via a number of established locations including;
Sydney - Newcastle - Central Coast - Wollongong
SureSearch are the only business of its type to have dedicated teams of Allocators, Estimators, Project Managers, Surveyors, Draftsmen, Utility Locators, CCTV Technicians and Vac Truck Operators. All SureSearch field staff are issued with iPads to allow them to produce onsite reports for all services conducted which are then sent directly to the client.
Concrete Scanning
SureSearch provide concrete scanning using Ground Penetrating Radar Concrete (GPRC) and Electromagnetic Locating (EML). Concrete Scanning is ideal to confirm the location and setout of reinforcement, post-tension and pre-tension cables, ducts, structural beams and voids, and should be used prior to commencing core drilling, concrete cutting, dyna-drilling, wall-sawing or cutting, and the removal of concrete floors or walls.
SureSearch has the capabilities and equipment to precisely detect the entry or exit point of penetrations for you to understand and confirm your work location.
We compile all our findings into SureSearch specific detailed reports for engineers, contractors, owners and surveyors
GPRC is ideal for determining:• Location of Post and Pre-tension cables and ducts• Approximate depth of slab• Location of thickenings and beams• Live electrical cables and more• Inconsistencies such as voids, cracks and honeycombing• Schmidt hammer testing to determine compressive
strength (mPa)• Cover meters to provide spacing, size and depth of
reinforcement
Our fleet of over 50 vehicles and 70 staff and growing ensure we can offer the following services:
Our Capabilities
• Utility Locating
• Concrete Scanning
• Survey Solutions
• Utility Mapping
• CAD & BIM Modeling
• CCTV Inspection
• High Velocity Drain Cleaning
• Non-Destructive Excavation
• Topographic Surveys
SureSearch is a leader in the utility locating, mapping and asset protection industry.
2 3
Survey & Mapping
4
SureSearch has a team of highly qualified and experienced surveyors who are experts at translating utility information to engineering grade survey data. We specialise in Utility surveys, Topographical surveys and construction grade survey control.
Our surveyors and drafters are skilled in using the latest CAD software, including 12d for survey reduction & design, AutoCAD & Civil 3d for drafting/modelling and CompNet for reducing complex survey control networks.
Our surveyors use equipment that are the latest in technology, including• 1" Trimble Robotic Total Stations • Trimble 3D Scanners • RTK and Static GNSS solutions• Digital Levels
SW-D
SW-D
SW-D
SW-DSW-D
SW-DSW-D
SW-DSW-D
SW-DSW-D
SW-DSW-D
SW-D
SW-D
SW-D
SW-D
SW-D
SW-D
SW-D
SW-D
SW-D
SW-D
SW-D
SW-D
SW-D
SW-D
SW-D
SW-D
SW-D
SW-D
SW-D
SW-D
SW-DSW-D
SW-DSW-D
SW-DSW-D
SW-DSW-D
SW-B
SW-B
SW-B
SW-B
SW-B
SW-B
SW-B
SW-B
SW-B
SW-B
SW-B
SW-B
SW-B
SW-B
SW-CSW-C
SW-CSW-C
SW-CSW-C
SW-C
SW-C
SW-C
SW-C
SW-C
SW-CSW-C
SW-CSW-C
SW-C
SW-C
SW-C
SW-C
SW-C
SW-CSW-C
WM
-BW
M-B
WM
-B
WM
-BW
M-B
WM
-BW
M-B
WM
-BW
M-B
WM
-BW
M-B
WM
-BW
M-B
WM
-BW
M-B
WM
-BW
M-B
WM
-BW
M-BWM-B
WM-B
WM-B
WM
-BW
M-B
WM
-BW
M-B
WM
-BW
M-B
WM
-B
WM-B WM-B WM-B WM-B
WM-BWM-B
WM-BWM-B
WM-BWM-B
WM-BWM-B
WM-BWM-B
WM-BWM-B
WM-BWM-B
WM-BWM-B
WM-BWM-B
WM-B
WM
-B
WM
-B
WM
-B
WM
-B
WM
-B
WM
-B
WM
-B
WM
-B
WM
-B
WM
-B
WM
-B
WM
-BW
M-B
WM
-BW
M-B
WM
-BW
M-B
WM
-BW
M-B
WM
-BW
M-B
WM
-BW
M-B
WM
-BW
M-B
WM-B
WM-B
WM-BWM-B
WM-BWM-B
WM-BWM-B
WM-BWM-B
WM-BWM-B
WM-BWM-B
WM-BWM-B
WM-BWM-B
WM-BWM-B
WM-BWM-B
WM-BWM-B
WM-B
WH
WH
WH
WH
WH
WH
WH
WH
OU-BOU-B
OU-BOU-B
OU-B
OU-BOU-B
OU-BOU-B
OU-B
OU-BOU-B
OU-BOU-B
OU-BOU-B
OU-BOU-B
OU-BOU-B
OU-BOU-B
OU-BOU-B
OU-BOU-B
OU-BOU-B
OU-B
OU-BOU-B
OU-BOU-B
OU
-BO
U-B
OU-BOU-B
OU-BOU-B
OU-B
OU-B
OU
-BO
U-B
OU
-BO
U-B
OU
-BO
U-B
OU
-BO
U-B
OU
-BO
U-B
OU
-BO
U-B
OU
-B
OU-BOU-B
OU-BOU-B
OU-BOU-B
OU-B
OU
-B
OU
-B
OU-BOU-B
OU-BOU-B
OU-BOU-B
OU-B
OU-BOU-B
OU-BOU-B
OU-BOU-B
OU-BOU-B
OU-BOU-B
OU-BOU-B
OU-B
OU-B
OU-B
OU-B
OU-B
OU-B
OU-B
OU-B
OU-B
OU-B
OU-B
OU
-B
OU
-B
OU
-B
OU
-B
OU
-B
OU-BOU-B
OU-B
OU-B
OU-B
OU
-BO
U-B
OU
-BO
U-B
OU
-BO
U-B
OU
-BO
U-B
OU
-BO
U-B
OU
-BO
U-B
OU
-BO
U-B
OU
-BO
U-B
OU
-B
OU-DOU-D
OU-DOU-D
OU-D
OU-D
OU-D
OU-D
OU-D
OU-D
OU-D
OU-D
OU
-DO
U-D
OU
-DO
U-D
OU
-DO
U-D
OU
-DO
U-D
OU
-DO
U-D
OU
-DO
U-D
OU
-DO
U-D
OU-DOU-D
SM-D
SM-D
SM-D
SM-D
SM-D
SM-D
SM-D
SM-D
SM-D
SM-D
SM-D
SM-D
SM-D
SM-CSM-C
SM-CSM-C
SM-CSM-C
SM-CSM-C
SM-CSM-C
SM-CSM-C
SM-CSM-C
SM-C
SM-CSM-C
SM-CSM-C
SM-CSM-C
SM-CSM-C
SM-CSM-C
SM-C
SM-C
SM-C
SM-C
SM-C
SM-C
SM-C
SM-C
SM-C
SM-C
SM-C
SM-C
SM-C
SM-C
SM-C
SM-CSM-C
SM-CSM-C
SM-CSM-C
SM-CSM-C
SM-CSM-C
SM-CSM-C
SM-C
SM-CSM-C
SM-CSM-C
SM-CSM-C
SM-CSM-C
SM-CSM-C
LG-DLG-D
LG-DLG-D
LG-DLG-D
LG-DLG-D
LG-DLG-D
LG-DLG-D
LG-DLG-D
LG-D
LG-D LG-D LG-D LG-D LG-DLG-D
LG-DLG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-D
LG-DLG-D
LG-DLG-D
LG-DLG-D
LG-DLG-D
LG-D
LG-D
LG-D
LG-D
LG-DLG-D
LG-DLG-D
LG-DLG-D
LG-DLG-D
LG-DLG-D
LG-DLG-D
LG-DLG-D
LG-D
LG-D
WM-DWM-D
LG-D
LG-D
LG-DSLH
LG-BLG-B
LG-B
LG-B
LG-B
WM
-DW
M-D
-0.5m
-0.6m
-0.6m
-0.3m
-0.4m
-0.5m
-1.3m
-0.3m
-0.4m
-0.4m
-0.5m
-0.2m
-0.3m
-0.3m
-0.7m
-0.8m
-0.4m
-0.4m
-0.6m
-0.7m
-0.2m
-0.1m
-0.5m
-0.1m
-0.1m
-0.2m
-0.5m
-0.3m
-0.3m
-0.3m
-0.3m
-0.2m
-0.2m
-0.2m
-0.5m
-0.7m
-0.4m
-0.3m
-0.2m
-0.4m
-0.4m
-0.6m
-0.7m
-0.7m
-0.5m
-0.7m
-0.8m
-0.7m
-0.8m
-0.8m
-0.5m
-0.8m
-0.6m
-0.5m
-0.5m
-0.6m
-0.5m
-0.3m
-0.5m
-0.3m
-0.8m
-0.8m
-0.4m
-0.4m
-0.9m
-0.5m
-0.4m -0
.3m
-0.4m -0
.3m
-0.3m
-0.3m
-0.3m
-0.3m
-0.3m
-0.3m
-0.2m
-0.2m
-0.3m
-0.3m
-0.5m
-0.6m
-0.4m
-0.3m -0.2m -0
.3m
-0.3m
-0.1m
-0.2m
-0.2m
-0.2m
-0.1m
-0.3m
-0.2m
-0.2m
-0.2m
-0.3m
-0.5m
-0.4m
-0.3m
-0.3m
-0.3m
-0.2m
-0.2m
-0.2m
-0.1m
-0.2m
-0.2m
-0.2m
-0.3m
-0.4m
-0.3m
-0.3m
-0.4m
-0.2m
-0.1m
-0.2m
-0.2m
-0.3m
-0.2m
-0.3m
-0.4m
-0.4m
-0.3m
-0.3m
-0.3m
-0.2m
-0.1m
-0.2m
-0.2m
-0.2m
-0.2m
-0.2m
-1.8m
-2.5m
-0.4m
-1.5m
-1.82
m
-1.7m
-2.6m
-2.6m
-1.9m
-1.6m
-1.6m
-0.6m
-0.7m
-0.5m
-0.6m
-0.6m
-0.7m
-0.6m
-0.3m
-0.4m
-0.4m
-0.8m
-0.4m
-0.3m
-0.9m
-0.4m
-0.3m
WATER MAINHOUSE FEED
WATER MAINHOUSE FEED
FULL OFDEBRIS
GAS MAIN QL-DHOUSE FEED
GPR SCAN
-0.4m
WATER MAINHOUSE FEED
WATER MAINHOUSE FEED
EOT
WATER MAINHOUSE FEED
WATER MAINHOUSE FEED
GAS MAIN QL-DHOUSE FEED
WATER MAINHOUSE FEED
PIT NOT SEEN ON SITEAS PER DBYD
FULL OFDEBRIS
NO. 3CONSTRUCTION SITE
GAS NOT VISIBLE
NO. 10GAS NOT VISIBLE
EOT
EOT
EOT
NO. 1CONSTRUCTION SITE
GAS NOT VISIBLE
NO. 4GAS NOT VISIBLE
WATER NOT VISIBLE
NO. 5GAS NOT VISIBLE
WATER NOT VISIBLE
NO. 3GAS NOT VISIBLE
WATER NOT VISIBLE
NO. 2GAS NOT VISIBLE
WATER NOT VISIBLE
NO. 1GAS NOT VISIBLE
WATER NOT VISIBLE
HYDRANT NOTVISIBLE ONSITE
MARKED OFF DBYD
STOP VALVE NOTVISIBLE ONSITE
MARKED OFF DBYD
WATER MAINHOUSE FEED
GAS MAIN QL-DHOUSE FEED
GAS MAIN QL-DHOUSE FEED
GAS MAIN QL-DHOUSE FEED
GAS MAIN QL-DHOUSE FEED
GAS MAIN QL-DHOUSE FEED
WATER MAINHOUSE FEED
WATER MAINHOUSE FEED
WATER MAINHOUSE FEED
WATER MAINHOUSE FEED
TELSTRA CABLEAND OPTIC FIBRE1 x Ø15mm PVC
TELSTRA CABLEAND OPTIC FIBRE1 x Ø15mm PVC
TELSTRA CABLEAND OPTIC FIBRE1 x Ø15mm PVC
TELSTRA CABLEAND OPTIC FIBRE1 x Ø15mm PVC
TELSTRA CABLEAND OPTIC FIBRE1 x Ø15mm PVC
JEMENA QL-DGAS MAIN
4NB Ø32mm NYGPR SCAN
SYDNEY WATERWATER MAINØ100mm CICL
JEMENA QL-DGAS MAIN
4NB Ø32mm NYGPR SCAN
JEMENA QL-DGAS MAIN
4NB Ø32mm NYGPR SCAN
SYDNEY WATERWATER MAINØ100mm CICL
SYDNEY WATERWATER MAINØ100mm CICL
SYDNEY WATERWATER MAINØ100mm CICL
SYDNEY WATERWATER MAINØ100mm CICL
SYDNEY WATERWATER MAINØ100mm CICL
JEMENA QL-DGAS MAIN
4NB Ø32mm NYGPR SCAN
JEMENA QL-DGAS MAIN
4NB Ø32mm NY
GAS MAIN QL-DHOUSE FEED
GAS MAINHOUSE FEED
TELSTRA CABLE QL-DNO SIGNAL
TELSTRA CABLEAND OPTIC FIBRE1 x Ø10mm PVC
TELSTRA CABLEAND OPTIC FIBRE1 x Ø10mm PVC
TELSTRA CABLE QL-DNOT SEEN ONSITE
TELSTRA CABLE QL-DAND OPTIC FIBRENOT SEEN ONSITE
TELSTRA CABLEAND OPTIC FIBRE
1 x DIRECT BURIED
JEMENA QL-DGAS MAIN
4NB Ø32mm NY
GAS MAINHOUSE FEED
TELSTRA CABLEAND OPTIC FIBRE1 x Ø20mm PVC
TELSTRA CABLEAND OPTIC FIBRE1 x Ø50mm PVC
SYDNEY WATERWATER MAIN
Ø75mm PECICL ENCASED
SYDNEY WATER QL-DWATER MAINØ100mm CICL
NO SIGNAL
WATER MAINHOUSE FEED
WATER MAINHOUSE FEED
GAS MAIN QL-DHOUSE FEED
WATER MAINHOUSE FEED
SYDNEY WATERWATER MAINØ100mm CICL
JEMENA QL-DGAS MAIN
END OF LINE
TELSTRA CABLEAND OPTIC FIBRE1 x Ø30mm PVC
TELSTRA CABLEAND OPTIC FIBRE1 x Ø20mm PVC
TELSTRA CABLEAND OPTIC FIBRE1 x Ø30mm PVC
TELSTRA CABLEAND OPTIC FIBRE1 x Ø20mm PVC
TELSTRA CABLEAND OPTIC FIBRE1 x Ø20mm PVC
TELSTRA CABLEAND OPTIC FIBRE1 x Ø20mm PVC
TELSTRA CABLEAND OPTIC FIBRE1 x Ø30mm PVC
TELSTRA CABLE QL-DAND OPTIC FIBRE1 x Ø35mm PVC
NOT SEEN ONSITE
TELSTRA CABLE QL-DAND OPTIC FIBRE1 x Ø35mm PVC
NOT SEEN ONSITE
TELSTRA CABLE QL-DNOT SEEN ONSITE
SYDNEY WATERWATER MAINØ100mm CICL
SYDNEY WATERWATER MAINØ100mm CICL
WATER MAINHOUSE FEED
WATER MAINHOUSE FEED
GAS MAINHOUSE FEED
GAS MAIN QL-DHOUSE FEED
GAS MAIN QL-DHOUSE FEED
GAS MAIN QL-DHOUSE FEED
WATER MAINHOUSE FEED
WATER MAINHOUSE FEED
EOT
TELSTRA CABLEAND OPTIC FIBRE
1 x Ø100mm E
TELSTRA CABLEAND OPTIC FIBRE
1 x Ø100mm E
TELSTRA CABLEAND OPTIC FIBRE1 x Ø100mm PVC
TELSTRA CABLEAND OPTIC FIBRE1 x Ø100mm PVC
FULL OF DEBRISNOT SHOWN ON
DBYD
TELSTRA CABLE QL-DAND OPTIC FIBRE1 x Ø50mm PVC
NOT SEEN ONSITE
JEMENAGAS MAIN
4NB Ø32mm NY
JEMENA QL-DGAS MAIN
4NB Ø32mm NY
JEMENA QL-DGAS MAIN
4NB Ø32mm NYGPR SCAN
NOT SHOWNON DBYD
TELSTRA CABLEAND OPTIC FIBRE1 x Ø100mm CONC
TELSTRA CABLE QL-DAND OPTIC FIBRE1 x Ø20mm PVC
NO SIGNAL
TELSTRA CABLEAND OPTIC FIBRE1 x Ø50mm PVC
VOID UNDERCONCRETE
PIT BURIEDNOT VISIBLE
ONSITE
TELSTRA CABLEAND OPTIC FIBRE
1 x Ø100mm A
TELSTRA CABLEAND OPTIC FIBRE1 x Ø30mm PVC
WATER MAINHOUSE FEED
TELSTRA CABLEAND OPTIC FIBRE1 x Ø30mm PVC
TELSTRA CABLE QL-DAND OPTIC FIBRENOT SEEN ONSITE
TELSTRA CABLEAND OPTIC FIBRE
1 x Ø50mm A
TELSTRA CABLEAND OPTIC FIBRE
1 x Ø100mm A
TELSTRA CABLE QL-DAND OPTIC FIBRE1 x Ø50mm PVC
NOT SEEN ONSITE
TELSTRA CABLE QL-DAND OPTIC FIBRE1 x Ø50mm PVC
NOT SEEN ONSITETELSTRA CABLE
AND OPTIC FIBRE1 x Ø50mm PVC
GAS MAIN QL-DHOUSE FEED
WATER MAIN QL-DHOUSE FEED
EOT
EOT
UNABLE TO LIFTCONCRETE LID
SE01
SE02
SE03
SYDNEY WATER QL-DSEWER MAINØ150mm SGW
SYDNEY WATER QL-DSEWER MAINØ150mm SGW
END OF LINE
DEPTHFROM DBYD
DEPTHFROM DBYD
UNABLE TO LIFTBITUMEN OVER
EDGES
DEPTHFROM DBYD
UNABLE TO LIFTBITUMEN OVER
EDGES
DEPTHFROM DBYD
UNABLE TO LIFTBITUMEN OVER
EDGES
DEPTHFROM DBYD
SYDNEY WATERSEWER MAINØ150mm SGW
SYDNEY WATERSEWER MAINØ150mm SGW
SYDNEY WATERSEWER MAINØ225mm SGW
SYDNEY WATERSEWER MAINØ225mm SGW
DEPTHFROM DBYD
SYDNEY WATERSEWER MAINØ150mm SGW
SYDNEY WATERSEWER MAINØ225mm SGW
DEPTHFROM DBYD
DEPTHFROM DBYD
DEPTHFROM DBYD
DEPTHFROM DBYD
UNABLE TO LIFTBITUMEN OVER
EDGES
UNABLE TO LIFTBITUMEN OVER
EDGES
SYDNEY WATERSEWER MAINØ225mm SGW
SYDNEY WATERSEWER MAINØ225mm SGW SYDNEY WATER QL-D
SEWER MAINØ150mm PVC
SYDNEY WATER QL-DSEWER MAINØ150mm SGW
UNABLE TO LIFTBITUMEN OVER
EDGES
DR01
DR02
DR03
-0.6m
DR07
DR06
DR09
DR08
DR05
DR10
DR04
DR13
DR12
DR11
DR15
DR14
DR16
DR17
DR18
DR19
DR20
DR21
EOT
STORMWATERØ375mm CONC
EOT
POSSIBLE BURIED PITCCTV REQUIRED TO
CONFIRM
STORMWATER QL-DØ900mm CONC
POSSIBLE BURIED PITCCTV REQUIRED TO
CONFIRM
STORMWATER QL-DØ900mm CONC
UNABLE TO LIFTCONCRETE LID
STORMWATER QL-DUNKNOWN CONFIG.
STORMWATER QL-DUNKNOWN CONFIG.
UNABLE TO LIFTCONCRETE LID
STORMWATER QL-DUNKNOWN CONFIG.
EOT
STORMWATER QL-DUNKNOWN CONFIG.
DR22
EOT
EOT
DR23
DR24
DR29
DR26
DR25
EOT
DR27
DR28
POSSIBLE BURIED PITCCTV REQUIRED TO
CONFIRM
POSSIBLE BURIED PITCCTV REQUIRED TO
CONFIRM
A1 Border version: January_2019
A1 SCALES
CO-ORDINATE SYSTEM: HEIGHT DATUM: AHDMGA
JOB NO. 67320_DOIGDOIG AVENUE, DENISTONE EAST
QL-B UTILITY INVESTIGATION
CITY OF RYDEORIGIN OF SURVEYSSM 95579
MGAE 323904.507
N 6259025.326AHD 89.354
FILE NAME:
MODEL NAME:
SURVEYED:
LOCATED:
REVIEWED:
67320_City of Ryde_Doig Ave Denistone East_V1
67320_Doig
DY
MN
BO
ISSUED BY: SHEET of SHEETS1 1PW
DATE:
DATE:
DATE:
DATE:
19-02-2020
31-01-2020
31-01-2020
19-02-2020
NOTES
INFORMATION CONTAINED IN THIS PLAN IS THECOPYRIGHT OF SURESEARCH UNDERGROUND SERVICES.
COPYING OR USING THIS DATA IN WHOLE OR PART, INANY FORMAT, WITHOUT PERMISSION INFRINGES
COPYRIGHT. © UNAUTHORISED USE OF THISINFORMATION IN ANY FORM WHATSOEVER IS
PROHIBITED.
MGA
N
1300 884 520www.suresearch.com.au
SUBSURFACE UTILITY INFORMATION (SUI) AS5488 LOCATION CLASSLabelling utility information by a classification code allows the user ofthis information to understand clearly how the information wascollected and then place an appropriate amount of reliance on it.Project risks related to underground utilities can then be properlymanaged.Line work sample; ---EU-B--- Quality level represented withinlinework, Underground Electricity (Quality Level 'B').QL-A: Information is the highest possible level of accuracy and isobtained by exposing the underground utility using a non-destructiveexcavation (pot holing) technique. The vertical information for thislocating method is to the top or shallowest part of the locatedservice. The 3D location is recorded by survey as an X, Y, Zcoordinate.QL-B: Information is collected by designating the horizontal andvertical location of underground utilities by using electromagneticpipe and cable locators, sondes or flexi-trace, ground penetratingradar and acoustic pulse equipment. This is the most common formof utility locating and although an X, Y and Z axis can be establishedit is not always entirely accurate due to differing electromagneticfields, soil conditions and multiple banks of cables affecting thelocating signal.QL-C: Information is collected by correlating the survey of visibleutility surface features such as marker plates or water hydrants andacquired Dial-Before-You-Dig plans to “draw” a string which showsthe approximate position of services. This method does not usuallyshow multiple banks of cables and does not always show threedimensional information. Electronically traced locate marks with poorscratchy signals are represented as QL-C.QL-D: Information is the most basic level of utility locations usingonly information based on existing Dial-Before-You-Dig plans and bymeasuring boundary offsets etc. This method of utility locationsshould always be treated as an indication of the presence of a serviceonly and should not be used for design. GPR scans are alsorepresented as QL-D as the GPR image cannot be confirmed to it'sorigin point. Depths on GPR scan must be treated as indicative only.
5 10 15 20 25
SCALE 1:250
0 www.dialbeforeyoudig.com.au
DIALCOMPILED: DATE:HB 19-02-2020
REVISION PANEL
NO. DATE REVISION DESCRIPTION---- ---- ----
ELECTRICITY EU-A-B-C-DTRANSMISSION
OPTIC FIBRETELECOMMUNICATIONS
xET-A-B-C-DTN-A-B-C-DOU-A-B-C-D
RMS RMS-A-B-C-DLOW PRESSURE GAS
WATER MAINHIGH PRESSURE GAS
LG-A-B-C-DHG-A-B-C-DWM-A-B-C-D
UNKNOWN SERVICE UP-A-D
SEWER MAINSTORMWATER
SM-A-B-C-DSW-A-B-C-D
xxx
xxx
x
xx
x
UTILITY ASSETS LEGEND
FIRE MAIN FH-A-B-C-Dx
PROPERTY BOUNDARYLIMIT OF SURVEY
LIGHT POLE
TELEPHONE TWIN PITTELEPHONE LARGE SUMP
TELEPHONE PIT
POWER AND LIGHT POLE
GAS VALVE BOX
END OF TRACE
HYDRANT
WATER TAP
WATER METERSTOP VALVE
SEWER MANHOLE
POWER POLECABLE MARKER
GAS PIPE MARKER
TOP OF SERVICEDEPTH TO INVERT OF PIPE
EOT
WH
GP
TOSIL
GAT
EP
EC
EJB
GATIC COVER
CABLE JUNCTION BOX
SEWER LAMP HOLE SLH
RMS TRAFFIC LIGHTRMS SIGNAL PIT
DPDRAINAGE DOWN PIPESMALL DRAINAGE GULLY PIT
UNIDENTIFIED SERVICE ?
FIRE HYDRANT
SIGNDRAINAGE JUNCTION MANHOLE
GATE
-0.5m
DENOTES DEPTH TO SERVICE
FENCE / / / / / / / / / / /
ELTHAM
STREET
RICHMOND STREET
DO
IG
AVEN
UE
JACKSO
N C
RESC
ENT
MAS
ON
STR
EET
STORMWATER INFORMATIONREFERENCE QUALITY RL (INVERT OF PIPE) IL (DEPTH) m CONFIGURATION
DR01 QL-A 79.78 -1.12 375mm CONCDR02 QL-A 78.82 -1.30 375mm CONCDR03 QL-A 78.64 -1.35 375mm CONCDR04 QL-A 78.51 -1.10 375mm CONCDR05 QL-A 78.42 -1.25 600mm CONCDR06 QL-A 79.58 -1.20 600mm CONCDR07 QL-A 80.04 -0.75 375mm CONCDR08 QL-A 80.03 -0.75 375mm CONCDR09 QL-A 80.22 -0.70 300mm CONCDR10 QL-A 78.33 -1.27 600mm CONCDR11 QL-A 78.08 -1.14 600mm CONCDR12 QL-A 78.28 -1.03 375mm CONCDR13 QL-A 78.26 -1.00 375mm CONCDR14 QL-A 77.22 -2.10 900mm CONCDR15 QL-A 78.11 -1.26 375mm CONCDR16 QL-A 77.78 -1.34 375mm CONCDR17 QL-A 78.04 -0.90 375mm CONCDR18 QL-A 78.16 -0.84 375mm CONCDR19 QL-A 78.22 -0.82 375mm CONCDR20 QL-A 78.21 -0.76 375mm CONCDR21 QL-A 78.52 -0.50 300mm CONCDR22 QL-A 77.11 -0.70 375mm CONCDR23 QL-A 77.11 -0.64 375mm CONCDR24 QL-A 75.23 -1.96 900mm CONCDR25 QL-A 74.23 -1.34 1050mm CONCDR26 QL-A 74.19 -1.26 375mm CONCDR27 QL-A 74.33 -1.15 375mm CONCDR28 QL-A 74.74 -0.85 150mm PVCDR29 QL-A 74.06 -1.50 1050mm CONC
SEWER INFORMATIONREFERENCE QUALITY RL (INVERT OF PIPE) IL (DEPTH) m CONFIGURATION
SE01 QL-A 79.51 -1.37 150mm SGWSE02 QL-A 98.63 -2.25 150mm SGWSE03 QL-A 79.30 -1.56 150mm SGW
Survey deliverables• Survey plans • 12d/DWG CAD models, including BIM and 12d objects • Field reports and Interactive pdfs • Survey Control, Least Squares reductions suitable for
construction
SureSearch may be best known for providing high quality utility surveys, but we also provide equally high-quality surveys of design and investigative purpose. • Topographical Contour survey (Detail)• Point cloud surveys • Cadastral Surveys• Civil construction Setouts• Work as Executed surveys
SureSearch is part of the Roads & Maritime Survey Panel and have been successfully completing projects for RMS and associates on small to large scaled projects.
4 5
Utility Locating
3D Utility and Drainage Survey completed for RMS. Macquarie Park Upgrade
SureSearch has a dedicated team of utility locators who are all DBYD Certified. The team can help you map and protect all underground assets on your site thanks to SureSearch dedicated systems and processes. SureSearch uses both electromagnetic cable locating and ground penetrating radar (GPR) technology to designate underground utilities.
• EML Locating – Used to locate conductive utilities such as metallic pipes, electrical and communication cables
• Ground Penetrating Radar – Used to locate non conductive material such as Poly or Nylon gas lines, blue brute and uPVC water mains, empty conduits, underground storage tanks and possible underground voids
• Traceable Rod with EML – Used to locate accessible empty pipes or conduits i.e. Sewer and Storm water pipes and empty conduits.
All our work complies to the Australian Standard AS-5488.1:2019 classification of subsurface utility information, compiling this with our SureSearch specific detailed locate reports that are completed and sent directly from site to the client with the SureSearch trade mark of clear and accurate colour coded utility markings.
6 7
Non Destructive Excavation CCTV inspection
For detailed reports of existing assets, including storm water pipes, sewer pipes, wells, shafts and ducts we deploy closed circuit television (CCTV) technology. SureSearch’s CCTV inspection service allows our expert team to inspect, survey and record to WSA 05-2008 & WSA 05-2013 standards, all SureSearch CCTV operators are accredited to record and report to codes and standards.
• Push Rod CCTV – Used to inspect and locate 60mm – 150mm sewer and storm water conduits.
• CCTV Tractor – Can inspect sewer and storm water conduits from 150mm – 2m in diameter. Up to 500 lineal meters.
• Vehicle and portable options available for those locations with limited access
• WinCan reporting software used for all inspections
We have a fleet of non-destructive excavation trucks ranging in sizes and capabilities from 4x4 trucks to combination drain cleaning trucks, our tanks range in size from 4,000 liters to 10,000 liters.
Non-destructive excavation uses high pressure water and vacuum to safely expose and pothole underground utilities without damaging utilities or their coatings, making it ideal for road design, power and street light pole installation, tree planting & remediation and the exposure of underground utilities before excavation or ground disturbance:• Reduced reinstatement costs due to minimal
surface disruption• The risk of damaging subsurface utilities including
protective coatings is eliminated.• Cost effective and fast results• Easy disposal of excavated soil that is contained in the
vacuum tank at approved disposal transfer stations• Reduced manual handling removes the risk of
personal injury.• Vacuum excavation is a safer alternative to
conventional mechanical excavation therefore lowering environmental impacts.
Our vacuum units are fitted with specialist equipment allowing us to employ a range of techniques, including:• Hydro Vacuum Excavation, which combines high-
pressure water and a high-flow vacuum, allowing for quick, clean and precise evacuations.
• Air Excavation and Knifing, which uses high-pressure air compressors, to either pothole or excavate.
• Vacuum Excavation (or suction excavation), which is used for the removal of dry and wet materials, as well as to transfer debris and remove soil around and near underground utilities and services.
8 9
SureSearch has a fleet of combination hi velocity drain cleaning trucks. These trucks are capable of cleaning debris and roots from both storm water and sewer mains ranging from 150mm diameter to 1800mm diameter. These units not only clean the silted pipes, they also remove the debris from pits via the vacuum unit. With a powerful 1” Water jetting pump, pumping 333 l/min @ 170 bar and 180m x 1” sewer hose, our high-pressure jet cleaning is sure to remove any blockages in the pipe. A 6000L debris tank is large enough to carry all debris that has been cleaned from the pipe.
Pipe Rehabilitation Hi Velocity Drain Cleaning
SureSearch is the first NSW based installer of the quick-lock system. the quick-lock system is manufactured from self-locking V4A stainless steel sleeves & seamless EDPM rubber gaskets, and is capable of repairing many common defects found in pipes sized between 150 DN – 800 DN.
Quick_lock is a German engineered. no-dig, trenchless repair system for rehabilitating existing sewer & stormwater pipelines. Quick-lock installs quickly and is a flexible, structurally sound repair system with minimal labor, minimal prep and minimal risk. Costly excavation is a thing of the past when it comes to quick-lock. Quick-lock locks permanently, installs quickly with minimal disruption.
Certifications and Approvals:• Approved for RMS drainage repair• WSAA Apraisal• 50 year manufacturers life expectancy• Passed jetting resistance test to
DIN-19523
11
PIT OW
NER
SERVIC
E TYPE
STRU
CTU
RE TYPE
PIT CO
VER SIZE
1300 884 520w
ww
.suresearch.com.au
15 Old Prospect R
d,South W
entworthville N
SW 2145
PO Box 3276
Um
ina Beach NSW
2257
PHO
TOG
RAPH
S
NO
TES
CLIEN
T:LO
CATIO
N:
SUR
VEYED BY:
PRO
JECT N
O:
DATE:
NO
T TO SC
ALE
ASSU
MED
NO
RTH
PIT INVER
T DEPTH
INTER
NAL C
HAM
BER SIZE
LEGEN
D
LVELEC
TRIC
ITYW
ATERSTO
RM
WATER
SEWER
GAS
TELSTRA AN
DO
PTIC FIBR
EU
NKN
OW
NH
VELEC
TRIC
ITY
TOP
TOP
TOP
TOP
SERVIC
E PIT REFER
ENC
E:
SERVIC
E PIT REPO
RT
22 Powers R
oadSeven H
ills NSW
2147
F-FD07 U
tility Service Pit Report January 2019
RO
ADS & M
ARITIM
E SERVIC
ESPR
INC
ES HIG
HW
AY & BOLO
NG
RO
ADN
OW
RA 2541
10/04/19
60841M
H01
DAN
IEL YOO
CO
MM
UN
ICATIO
NS
CO
NC
RETE
1.23m x 1.27m
1.65m
N/A
DIR
T AT BOTTO
M O
F PIT
North
East
West
Sou
TELSTRA
TREN
CH
REPO
RT
1300 884 520
ww
w.suresearch.com
.au
15 Old Prospect R
d,
South Wentw
orthville NSW
2145
PO Box 3276
Um
ina Beach NSW
2257
CLIEN
T:
LOC
ATION
:
SUR
VEYED BY:
TREN
CH
REFER
ENC
E:
PRO
JECT N
O:
DATE:
NO
T TO SC
ALE
NO
TES
ASSETSIZE
MATER
IAL
GR
OU
ND
LEVEL
GR
OU
ND
LEVEL
D E P T H O F T R E N C H
F-FD08 U
tility Trench Report August 2016 v
LEGEN
DLV
ELECTR
ICITY
WATER
STOR
MW
ATERSEW
ER
GAS
TELSTRA AN
D
OPTIC
FIBRE
UN
KNO
WN
HV
ELECTR
ICITY
1
TOP O
F SERVIC
E
22 Powers Road
Seven Hills NSW 2147
F-FD08 Utility Trench Report January 2019
AAPT
VOCUS
JEMENA
TELSTRA/ SUPERLOO
P
OPTUS
50mm
100mm
50mm
4 x 100mm
100mm
PVC
PVC
NYLON
PVC
PVC
1.04m
0.52m
0.57m
0.55mm
-0.72mm
1.12m
N/A
Macquarie Park
31.07.19
12345xxx15
A.Bridges
Unknown Found, adjacent to optus 80mm
direct buried cable possibly redundant electrical.
SureSearch has been helping home and property owners locate plumbing leaks since 2000. Identifying the source of a leak and tracing the location or damage is key to maintaining efficient and effective pipes, while limiting structural damage, water loss and unnecessary costs. SureSearch uses a range of proven methods to identify the location and cause of the leak, as well as to remedy the problem.
• Pressure testing
• Nitrogen Sniffer testing
• Correlation test between valves/hydrants on mains
• waterproof flood testing
• Thermal imaging camera
Providing a comprehensive report that is emailed to the client while on site, this provides next steps to remedy the leak issue.
Leak Detection Reporting
Our comprehensive reporting that is completed and emailed to the client on site is one of the many services that sets SureSearch ahead of our competitors.
These reports are completed for every utility locating job no matter the size. A mud map can also be produced on top of a google map image showing approx. location of the services found
Potholing reports are completed by our non-destrcutive excavation operators, these reports give our clients
photo evidence, depths, size and material of the service that has been found in the ground. Along with this report an additional pothole card can be produced that gives a visual representation of the hole/trench that was dug along with the configuration of the services found, depths and sizes.
Having these reports allows our client to keep valuable information on file for future works without having to relocate and pothole services, saving them time and money.
12
AccreditationsSafety
Clients we work with
SureSearch has a dedicated work health and safety, environment and quality management team that are constantly aiming to improve our employees lives by creating a workplace where they thrive and are more productive because they’re supported by management that cares.
At Suresearch we strive to continuously improve the health, wellbeing and safety in our workplaces so as to protect the wellbeing of and prevent injury or illness to our employees and the communities in which we operate.
SureSearch has an established, documented and implemented certified Integrated Management System to meet the requirements of Internationally recognised standards, ISO9001, ISO14001, OHSAS18001 and Australian/New Zealand Standard AS/NZS4801. The processes SureSearch adheres to are managed by the company in accordance with the requirements of these standards. Documented information, including relevant documents and records, are maintained to provide evidence of compliance and to ensure these processes remain effective.
We have a dedicated project department (team) who are experienced project managers with extensive experience in underground utilities who can help and cater to your specific work requirements from residential to multifaceted civil, structural, construction, infrastructure and transport. We can price, organise and facilitate works from start to finish professionally and feasible for our clients.
Project Management
14 15
P 1300 88 45 20
W suresearch.com.au
S Y D N E Y C E N T R A L C O A S T N E W C A S T L E W O L L O N G O N G B R I S B A N E M E L B O U R N E
19-S
SCH
-067
5